Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
RACER IWARM SYSTEM : Main information Our IWARM system isthe Electronic part which ismountedintoourgloves to make Heated gloves The system ismade off differentsparts - Twoelectronic modules : Master module (for right hand) and Slave module (for LeftHand). - 2 heated patch (made wwithCarbon microwire) - Two2200 mAh 2S1P LIPO batteries - 1 LIPO batterycharger 8.4V –2A Batteries and Charger are alreadycertified. So theyare out of the scope of your certification. The electronic system containstwoPCBAs(MASTER Boardand SLAVE Board). MASTER ad SLAVE PCBA are the same design exceptsomecomponents are not mountedon SLAVE PCBA (Slave boardhas lessfunctionscompare to Master Board) The system isworkingas below: - Bothboardscommunicateby 2.4 GHz radiofrequence - Master Boardsendordersto Slave Boardwhich followsinstruction to workin same mode as Master Board Regardingthe certification : - Master Boardisthe mostcriticalpart regardingelectronic certification requirement. - Heating functioncan onlyoperatewhenbothmaster and slave PCBA are connected. This isthe reasonI provideyouwith Master and Slave .... The aim isto get certification of the wholesystem Master PCBA : With PCBA with Led, buttonand connector for heated patch Slave PCBA (youjusthave to power itby a 7.4V battery, - No button, - no LED - No connector for heated patch as no need for certification Heated patch to connectto Master PCBA. RACER IWARM SYSTEM : Normal Mode 1. Connectheated patch and Master PCBA 2. ConnectBattery on Slave PCBA 3. ConnectBattery on Master PCBA => BothLEDsof Master PCBA shouldlight on for 3s (White, Orange, Red dependingon the charge of the battery), thenswitch off. 4. Make a long Press(2s) Button on Master PCBA=> LEDsof Master PCBA shoulfblinkBlue untilconnectedto SLAVE PCBA, thenbecomefix White (Orange, RED, dependingof battery charge). 5. The system isactive and isheating at high level(maximum power). 6. Make severalshort pressto select othersheating level=> Theyare 3 levels. LEDsiindicatedthe currentlevel 7. Make a long press(Over 2 seconds) to put the system in Sleepmode 8. Go to Step4 to wkaeup the system High Medium Low Delivery : 6 X (1 Master PCBA + 1 Slave PCBA + 1 Heated Patch) RACER IWARM SYSTEM : RF Test Mode 1. ConnectBattery on Slave PCBA=> SLAVE Module starts automaticallyin Transmission Mode 2. ConnectBattery on Master PCBA => MASTER PCBA lights Green and start RF Communication with SLAVE Module. 3. Make short pressto change RF mode :=> Aftereachpress, the light of the ledischanging In Test Mode, the system isworkingas below. LED GREEN =>1 frame transmitted/receivedevery2s at 2402 MHz, 0 dBm LED RED =>1 frame transmitted/receivedevery2s at 2440 MHz, 0 dBm 0 LED BLUE =>1 frame transmitted/receivedevery2s at 2480 MHz, 0 dBm 0 In normal Mode, the frequencyis2480 MHz, 0dBm. Frame are transmittedevery6s Delivery : 4 X (1 Master PCBA + 1 Slave PCBA ) RACER –NEWHEATEDGLOVESCOLECTIONS All IWARMS01 System are goingto bemountedin ournew collections (severalmodel of gloves). AllglovesaregoingtousethesameelectronicIWARM 01 system It explainsthatweneedtocertifiedtheelctronicsystemitself(insteadof the gloves) Hereisthe currentlistof ournewmodel ofHeated Gloves : -EGLOVE Velo -EGLOVE Urban -CONNECTIC -HEAT -REACTION -ECOVER -IWARMURBAN EGLOVE4 VELOREACTIONEGLOVE4 URBAN FCC Statement This device complies with part 15 of the FCC rules. Operation is subject to the following two conditions: (1) thi s device may not cause harmful interference, and (2) this device must accept any interference received, incl uding interference that may cause undesired operation. Changes or modifications not expressly approved by the party responsible for compliance could void the user’ s authority to operate the equipment. NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursua nt to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful inte rference in a residential installation. This equipment generates uses and can radiate radio frequency energy a nd, if not installed and used in accordance with the instructions, may cause harmful interference to radio com munications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turn ing the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: ‐ Reorient or relocate the receiving antenna. ‐ Increase the separation between the equipment and receiver. ‐Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. ‐Consult the dealer or an experienced radio/TV technician for help important announcement Important Note: Radiation Exposure Statement This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 0cm between the radiator and your body. This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter. Country Code selection feature to be disabled for products marketed to the US/Canada. This device is intended only for OEM integrators under the following conditions: 1. The antenna must be installed such that 0 cm is maintained between the antenna and users, and 2. The transmitter module may not be co-located with any other transmitter or antenna, 3. For all products market in US, OEM has to limit the operation channels in CH0 to CH39 for 2.4G band by supplied firmware programming tool. OEM shall not supply any tool or info to the end-user regarding to Regulatory Domain change. As long as the three conditions above are met, further transmitter testing will not be required. However, the OEM integrator is still responsible for testing their end-product for any additional compliance requi…
Text truncated - open the document above for the full version.
(f) The module shall comply with the Category I equipment labeling requirements and CFR § 15.212(a)(1)(vi). The modular has its own FCC ID number. (g) The module shall comply with any applicable FCC RF exposure requirement which are based on the intended use/configurations. Yes, RF cexposure evaluation performed at 0cm. (h) The modular transmitter complies with all applicable FCC rules. Instructions for maintaining compliance are given in the user instructions. Yes If you have any questions, please feel free to contact us at the address shown below Sincerely Name/Title: Florent Katchikian/CEO Company: RACER SAS Address: 1 Rue de le Forge 13300 – Salon de Provence France Phone: + 33 490 732 942 Fax: / E-Mail: [email protected]
Page 1 of 4 FCC ID: 2A5VD-IWARM1 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity External Photos of the EUT Fig. 1 Fig. 2 Only Receiver Page 2 of 4 FCC ID: 2A5VD-IWARM1 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Fig. 3 Fig. 4 Page 3 of 4 FCC ID: 2A5VD-IWARM1 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Fig. 5 Fig. 6 Page 4 of 4 FCC ID: 2A5VD-IWARM1 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Fig. 7 Fig. 8
Page 1 of 1 FCC ID: 2A5VD-IWARM1 IC: 28425-IWARM1 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Label and Location Size: L: 2.0cm*W: 0.5cm Label Location IWARM SYSTEM FCC ID: 2A5VD-IWARM1 IC: 28425-IWARM1 HVIN : V1.4
Page 1 of 2 FCC ID: 2A5VD-IWARM1 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Internal Photos of the EUT Fig. 1 Fig. 2 Page 2 of 2 FCC ID: 2A5VD-IWARM1 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Fig. 3 Antenna
Page 1 of 3 FCC ID: 2A5VD-IWARM1 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity FCC RF Exposure Evaluation 1. Product Information FCC ID : 2A5VD-IWARM1 Product name : IWARM SYSTEM Test Model : V1.4 Power supply : DC 7.4V by Li-ion Polymer Battery, 2200mAh Bluetooth : 2402MHz ~ 2480MHz Channel Number : 40 channels for Bluetooth V5.0 (DTS) Channel Spacing : 2MHz for Bluetooth V5.0(DTS) Modulation Type : GFSK for Bluetooth V5.0 (DTS) Bluetooth Version : V5.0 Antenna Type : Ceramic Antenna Antenna Gain : 2.7dBi(Max.) Hardware version : IWARM SYSTEM (Master & Slave PCBAs) Software version : / Exposure category : General population/uncontrolled environment EUT Type : Production Unit Device Type : Portable Device Page 2 of 3 FCC ID: 2A5VD-IWARM1 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity 2. Evaluation method and Limit According to KDB447498 D01 General RF Exposure Guidance v06 Section 4.3.1 Standalone SAR test exclusion considerations: “Unless specifically required by the published RF exposure KDB procedures, standalone 1-g head or body and 10-g extremity SAR evaluation for general population exposure conditions, by measurement or numerical simulation, is not required when the corresponding SAR Test Exclusion Threshold condition, listed below, is satisfied. These test exclusion conditions are based on source-based time-averaged maximum conducted output power of the RF channel requiring evaluation, adjusted for tune-up tolerance, and the minimum test separation distance required for the exposure conditions.22 The minimum test separation distance is determined by the smallest distance from the antenna and radiating structures or outer surface of the device, according to the host form factor, exposure conditions and platform requirements, to any part of the body or extremity of a user or bystander (see 5) of section 4.1). To qualify for SAR test exclusion, the test separation distances applied must be fully explained and justified by the operating configurations and exposure conditions of the transmitter and applicable host platform requirements, typically in the SAR measurement or SAR analysis report, according to the required published RF exposure KDB procedures. When no other RF exposure testing or reporting is required, a statement of justification and compliance must be included in the equipment approval, in lieu of the SAR report, to qualify for the SAR test exclusion. When required, the device specific conditions described in the other published RF exposure KDB procedures must be satisfied before applying these SAR test exclusion provisions; for example, handheld PTT two-way radios, handsets, laptops & tablets etc.“ [(max. power of channel, including tune-up tolerance, mW)/ (min. test separation distance, mm)] · [√f (GHz)] ≤ 3.0 for 1-g SAR and ≤ 7.5 for 10-g extremity SAR, where: • f (GHz) is the RF channel transmit frequency in GHz • Power and distance are rounded to the nearest mW and mm before calculation • The result is rounded to one decimal place for comparison • 3.0 and 7.5 are referred to as the numeric thresholds in the step 2 below The test exclusions are applicable only when the minimum test separation distance is ≤ 50 mm and for transmission frequencies between 100 MHz and 6 GHz. When the minimum test separation distance is < 5 mm, a distance of 5 mm according to f) in section 4.1 is applied to determine SAR test exclusion. When one of the following test exclusion conditions is satisfied for all combinations of simultaneous transmission configurations, further equipment approval is not required to incorporate transmitter modules in host devices that operate in the mixed mobile and portable host platform exposure conditions. The grantee is responsible for documenting this according to Class I permissive change requirements. Antennas that qualify for standalone SAR test exclusion must apply the estimated standalone SAR to determine simultaneous transmission test exclusion. a) The [∑ of (the highest measured or estimated SAR for each standalone antenna configuration, adjusted for maximum tune-up tolerance) / 1.6 W/kg] + [∑ of MPE ratios] is ≤ 1.0. b)The SAR to peak location separation ratios of all simultaneously transmitting antenna pairs operating in portable device exposure conditions are all ≤ 0.04, and the [∑ of MPE ratios] is ≤ 1.0. 3. Refer Evaluation Method ANSI C95.1–1999: IEEE Standard for Safety Levels with Respect to Human Exposure to Radio Frequency Electromagnetic Fields, 3 kHz to 300 GHz. FCC KDB publication 447498 D01 General RF Exposure Guidance v06: Mobile and Portable Devices RF Exposure Procedures and Equipment Authorization Policies. FCC CFR 47 part1 1.1310: Radiofrequency radiation exposure limits. FCC CFR 47 part2 2.1093: Radiofrequency radiation exposure evaluation: portable devices Page 3 of 3 FCC ID: 2A5VD-IWARM1 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity 4. Conducted Power Results [BLE] Mode Channel Frequency (MHz) Peak Conducted Output Power (dBm) BT LE 0 2402 0.46 19 2440 0.51 39 2480 0.45 5. Manufacturing Tolerance [BLE] BT LE (Peak) Channel Channel 0 Channel 19 Channel 39 Target (dBm) 0 0 0 Tolerance ±(dB) 1.0 1.0 1.0 6. Evaluation Results 6.1 Standalone Evaluation [BLE] Band/Mode f (GHz) Antenna Distance (mm) RF output power S…
Text truncated - open the document above for the full version.
LLC ABRACON IS ISO9001-2015 CERTIFIED 5101 Hidden Creek Ln Spicewood TX 78669 Phone: 512-371-6159 | Fax: 512-351-8858 For terms and conditions of sales, please visit: www.abracon.com REVISED: 06.21.2018 ACAG0201-2450-T MSL = 1 Pb ELECTRICAL CHARACTERISTICS FEATURESAPPLICATIONS Item VSWR • • • • MECHANICAL DIMENSIONS (mm) Unit: mm GND PI Type Mat ching Network Feeding Line Clearance Area GND VIA 3.0 5.0 1.15 1.20 1.40 0.55 0.55 Antenna Dimensions Layout Dimensions LLC ABRACON IS ISO9001-2015 CERTIFIED 5101 Hidden Creek Ln Spicewood TX 78669 Phone: 512-371-6159 | Fax: 512-351-8858 For terms and conditions of sales, please visit: www.abracon.com REVISED: 06.21.2018 ACAG0201-2450-T MSL = 1 Pb ANTENNA RESPONSE – SMITH CHART AND RETURN LOSS S11 EVALUATION BOARD AND MATCHING CIRCUITS 6.5nH 0.5pF LLC ABRACON IS ISO9001-2015 CERTIFIED 5101 Hidden Creek Ln Spicewood TX 78669 Phone: 512-371-6159 | Fax: 512-351-8858 For terms and conditions of sales, please visit: www.abracon.com REVISED: 06.21.2018 ACAG0201-2450-T MSL = 1 Pb RADIATION PATTERNS Coordinates LLC ABRACON IS ISO9001-2015 CERTIFIED 5101 Hidden Creek Ln Spicewood TX 78669 Phone: 512-371-6159 | Fax: 512-351-8858 For terms and conditions of sales, please visit: www.abracon.com REVISED: 06.21.2018 ACAG0201-2450-T MSL = 1 Pb REFLOW SOLDERING STANDARD CONDITION PACKAGING Reel (4000 pcs/Reel) Dimensions: mm MSL-1 LLC ABRACON IS ISO9001-2015 CERTIFIED 5101 Hidden Creek Ln Spicewood TX 78669 Phone: 512-371-6159 | Fax: 512-351-8858 For terms and conditions of sales, please visit: www.abracon.com REVISED: 06.21.2018 ACAG0201-2450-T MSL = 1 Pb CAUTIONS 1. Static voltage 2. Ultrasonic cleaning 3. Soldering
Page 1 of 27 FCC ID: 2A5VD-IWARM1 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Appendix A RF Test Data for BLE (Conducted Measurement) Product Name: IWARM SYSTEM Test Model: V1.4 Environmental Conditions Temperature: 23.5 C Relative Humidity: 52.2% ATM Pressure: 100.0 kPa Test Engineer: Jack Cheng Supervised by: Li Huan Page 2 of 27 FCC ID: 2A5VD-IWARM1 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity A.1 6dB Bandwidth Test Result TestMode Antenna Channel DTS BW [MHz] FL[MHz] FH[MHz] Limit[MHz] Verdict BLE_1M Ant1 2402 0.708 2401.636 2402.344 0.5 PASS 2440 0.712 2439.636 2440.348 0.5 PASS 2480 0.712 2479.636 2480.348 0.5 PASS Page 3 of 27 FCC ID: 2A5VD-IWARM1 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Test Graphs BLE_1M_Ant1_2402 BLE_1M_Ant1_2440 BLE_1M_Ant1_2480 Page 4 of 27 FCC ID: 2A5VD-IWARM1 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Page 5 of 27 FCC ID: 2A5VD-IWARM1 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity A.2 Occupied Channel Bandwidth Test Result TestMode Antenna Channel OCB [MHz] FL[MHz] FH[MHz] Limit[MHz] Verdict BLE_1M Ant1 2402 1.0449 2401.494 2402.539 --- --- 2440 1.0648 2439.476 2440.541 --- --- 2480 1.0708 2479.471 2480.542 --- --- Page 6 of 27 FCC ID: 2A5VD-IWARM1 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Test Graphs BLE_1M_Ant1_2402 BLE_1M_Ant1_2440 BLE_1M_Ant1_2480 Page 7 of 27 FCC ID: 2A5VD-IWARM1 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Page 8 of 27 FCC ID: 2A5VD-IWARM1 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity A.3 Maximum conducted output power Test Result TestMode Antenna Channel Result[dBm] Limit[dBm] Verdict BLE_1M Ant1 2402 0.46 ≤30 PASS 2440 0.51 ≤30 PASS 2480 0.45 ≤30 PASS Page 9 of 27 FCC ID: 2A5VD-IWARM1 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Test Graphs BLE_1M_Ant1_2402 BLE_1M_Ant1_2440 BLE_1M_Ant1_2480 Page 10 of 27 FCC ID: 2A5VD-IWARM1 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Page 11 of 27 FCC ID: 2A5VD-IWARM1 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity A.4 Maximum power spectral density Test Result TestMode Antenna Channel Result[dBm/3-100kHz] Limit[dBm/3kHz] Verdict BLE_1M Ant1 2402 -14.5 ≤8.00 PASS 2440 -14.48 ≤8.00 PASS 2480 -14.52 ≤8.00 PASS Page 12 of 27 FCC ID: 2A5VD-IWARM1 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Test Graphs BLE_1M_Ant1_2402 BLE_1M_Ant1_2440 BLE_1M_Ant1_2480 Page 13 of 27 FCC ID: 2A5VD-IWARM1 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Page 14 of 27 FCC ID: 2A5VD-IWARM1 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity A.5 Band edge measurements Test Result TestMode Antenna ChName Channel RefLevel[dBm] Result[dBm] Limit[dBm] Verdict BLE_1M Ant…
Text truncated - open the document above for the full version.
Page 1 of 32 FCC ID: 2A5VD-IWARM1 Report No.: LCS220401139AEA Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity FCC TEST REPORT For RACER SAS IWARM SYSTEM Test Model: V1.4 Prepared for : RACER SAS Address : 1 Rue de le Forge 13300 – Salon de Provence France Prepared by : Shenzhen LCS Compliance Testing Laboratory Ltd. Address : 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel : (+86)755-82591330 Fax : (+86)755-82591332 Web : www.LCS-cert.com Mail : [email protected] Date of receipt of test sample : April 06, 2022 Number of tested samples : 2 Sample No. : 220401139A-1, 220401139A-2 Serial number : Prototype Date of Test : April 06, 2022 ~ May 16, 2022 Date of Report : May 17, 2022 Page 2 of 32 FCC ID: 2A5VD-IWARM1 Report No.: LCS220401139AEA Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity FCC TEST REPORT FCC CFR 47 PART 15 C(15.247) Report Reference No. ................. : LCS220401139AEA Date of Issue .................................. : May 17, 2022 Testing Laboratory Name ............ : Shenzhen LCS Compliance Testing Laboratory Ltd. Address .......................................... : 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Testing Location/ Procedure .......... : Full application of Harmonised standards ■ Partial application of Harmonised standards □ Other standard testing method □ Applicant’s Name ......................... : RACER SAS Address .......................................... : 1 Rue de le Forge 13300 – Salon de Provence France Test Specification Standard ......................................... : FCC CFR 47 PART 15 C(15.247) Test Report Form No.................... : LCSEMC-1.0 TRF Originator ................................ : Shenzhen LCS Compliance Testing Laboratory Ltd. Master TRF ..................................... : Dated 2011-03 Shenzhen LCS Compliance Testing Laboratory Ltd. All rights reserved. This publication may be reproduced in whole or in part for non-commercial purposes as long as the Shenzhen LCS Compliance Testing Laboratory Ltd. is acknowledged as copyright owner and source of the material. Shenzhen LCS Compliance Testing Laboratory Ltd. takes no responsibility for and will not assume liability for damages resulting from the reader's interpretation of the reproduced material due to its placement and context. EUT Description. .......................... : IWARM SYSTEM Trade Mark ..................................... : RACER Test Model ...................................... : V1.4 Ratings ........................................... : DC 7.4V by Li-ion Polymer Battery, 2200mAh Result ............................................ : Positive Compiled by: Supervised by: Approved by: Jin Wang/ Administrator Cary Luo/ Technique principal Gavin Liang/ Manager Page 3 of 32 FCC ID: 2A5VD-IWARM1 Report No.: LCS220401139AEA Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity FCC -- TEST REPORT Test Model............................... : V1.4 EUT......................................... : IWARM SYSTEM Applicant............................... : RACER SAS Address.................................. : 1 Rue de le Forge 13300 – Salon de Provence France Telephone............................... : / Fax.......................................... : / Manufacturer........................ : RACER SAS Address................................... : 1 Rue de le Forge 13300 – Salon de Provence France Telephone............................... : / Fax.......................................... : / Factory................................... : Shenzhen City Cardi St. Electronics Co., Ltd Address................................... : Third floor, Building C, HeXingLong, Technology Park, No.19, Tianyang 1st Road, Songgang, Baoan, Shenzhen – 518105 Guangdong Province - RPC Telephone............................... : / Fax.......................................... : / Test Result Positive The test report merely corresponds to the test sample. It is not permitted to copy extracts of these test result without the written permission of the test laboratory. Test Report No. : LCS220401139AEA May 17, 2022 Date of issue Page 4 of 32 FCC ID: 2A5VD-IWARM1 Report No.: LCS220401139AEA Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Revision History Report Version Issue Date Revision Content Revised By 000 May 17, 2022 Initial Issue --- Page 5 of 32 FCC ID: 2A5VD-IWARM1 Report No.: LCS220401139AEA Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity TABLE OF CONTENTS 1. GENERAL INFORMATION ................................................................................................................................... 6 1.1. DESCRIPTION OF DEVICE (EUT) ...................…
Text truncated - open the document above for the full version.
Page 1 of 1 FCC ID: 2A5VD-IWARM1 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Test Setup Photos of the EUT Test Setup Photo(s) of Radiated Emissions Measurement Fig. 1 Fig. 2
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 2.40 GHz - 2.48 GHz | 1.10 mW |