Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: -- Reorient or relocate the receiving antenna. -- Increase the separation between the equipment and receiver. -- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. -- Consult the dealer or an experienced radio/TV technician for help. Warning: changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment Radiation Exposure Statement This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 20cm between the radiator and your body.
ZHONGSHANGUZHENYESHENGLIGHTING FACTORY AgentAuthorization Company:ZHONGSHANGUZHENYESHENGLIGHTINGFACTORY Address:F.3,NO.38xinxingeast road,Guzhengtown,Zhongshan city,Guangdongprovince,China ProductName:ceilingfan light ModelNumber(s):2048,2005,2019,2022,744,2002,2001,2034,Y003,753,729,731, 2045,733,C075,C076,C077,712,739 ProductDescription:ceilingfan light WeauthorizeMiCOMLabsInc.,575BoulderCourt,Pleasanton,California94566,USA, to actonourbehalfonallmattersconcerningthecertificationof abovenamed equipment. WedeclarethatMiCOMLabsInc.is allowedto forwardallinformationrelatedto the approvalandcertificationof equipmentto theregulatoryagenciesasrequiredandto discussanyissuesconcerningtheapprovalapplication.Anyandallactscarriedoutby MiCOMLabsonourbehalfshallhavethesameeffectasactsof ourown. Date:03/29/2022 Signature: Name: Christine Chen Title: Manager Company: ZHONGSHAN GUZHEN YESHENG LIGHTING FACTORY
ZHONGSHANGUZHENYESHENGLIGHTING FACTORY Office of EngineeringTechnology FederalCommunicationsCommission 7435 OaklandMills Road Columbia,MD 21046 USA Date: 03/29/2022 Subject;Requestfor Confidentiality FCC ID: 2A5ZW-2048 To WhomIt May Concern, Pursuantto the provisionsof the Commission’s rules Title 47 Sections§0.457 and §0.459,we are requestingthe Commissionto withholdthe followingattachment(s)as confidential documentsfrom public disclosureindefinitely. Thesedocumentscontaindetailedsystemand equipmentdescriptionsand are consideredas proprietaryinformationin operationof the equipment.The public disclosureof these documents might be harmfulto our companyand would give competitorsan unfair advantagein the market. SchematicDiagram Block Diagram Parts List OperationalDescription Tune-upProcedure In additionalto abovementioneddocuments,in order to complywith the marketingregulations in Title 47 CFR §2.803 and the importationrules in Title 47 CFR §2.1204,while ensuringthat businesssensitiveinformationremainsconfidentialuntil the actualmarketingof newly authorizeddevices,we requestShort Term Confidentialityof the followingattachment(s); ExternalPhotos Test Setup Photos InternalPhotos User Manual For 45 days, pursuantto PublicNoticeDA 04-1705. OR For 180 days pursuantto KDB 726920D01. It is our understandingthat all measurementtest reports,FCC ID label formatand correspondenceduringthe certificationreviewprocesscannotbe grantedas confidential documentsand this informationwill be availablefor public reviewonce the grant of equipment authorizationis issued. Sincerely, Signature: Name:ChristineChen Title:Manager
Modeldifferencedeclarationletter DifferencesDescription WeZHONGSHANGUZHENYESHENGLIGHTINGFACTORYstate: Product:ceilingfanlight ModelName: 2048/2005/2019/2022/744/2002/2001/2034/Y003/ 753/729/731/2045/733/C075/C076/C077/712/739 Theaboveproductwithsamecircuit,PCBlayout,electricalparts,materialsand wiringstructures,Appearanceshape,thematerialsofdecorativeaccessoriesis same,onlydifferentcolor. Signatory Date:03-29-2022 <Signature> Name:ChristineChen Title:manager Company:ZHONGSHANGUZHENYESHENGLIGHTINGFACTORY Address:F.3,NO.38xinxingeastroad,Guzhengtown,Zhongshancity,Guangdongprovince,China
Page1of3ReportNo.:FCS202203123 Externalphotos Photo1 Photo2 Page2of3ReportNo.:FCS202203123 Photo3 Photo4 Page3of3ReportNo.:FCS202203123 Photo5 Photo6
LabelandLabelLocation FCCID:2A5ZW-2048 L*W:10mm*5mm labelandWhitefont
Page1of5ReportNo.:FCS202203123 Internalphotos Photo1 Photo2 Page2of5ReportNo.:FCS202203123 Photo3 Photo4 Page3of5ReportNo.:FCS202203123 Photo5 Photo6ANT Page4of5ReportNo.:FCS202203123 Photo7 Photo8 Page5of5ReportNo.:FCS202203123 Photo9
Page1of2ReportNo.:FCS202203123W02 FluxComplianceServiceLaboratory Room105FloorBaohaoTechnologyBuilding1NO.15GongyeWestRoadHi-TechIndustrial,SongshanlakeDongguan Tel:769-27280901Fax:769-27280901http://www.FCS-lab.com FCCRFExposure EUTDescription:ceilingfanlight ModelNo.:2048,2005,2019,2022,744,2002,2001,2034,Y003,753,729,731,2045,733,C075,C076,C077,712,739 FCCID:2A5ZW-2048 Equipmenttype:fixedequipment 1.Limits Thecriterialistedinthefollowingtableshallbeusedtoevaluatetheenvironmentimpactofhuman exposuretoradiofrequency(RF)radiationasspecifiedin1.1307(b) LimitsforMaximumPermissibleExposure(MPE) F=frequencyinMHz Formula:Pd=(P out *G)/(4*π*r 2 ) Where: Pd=powerdensityinmW/cm 2 , Pout=outputpowertoantennainmW; G=gainofantennainlinearscale, π=3.14; R=distancebetweenobservationpointandcenteroftheradiatorincm PdidthelimitofMPE,1mW/cm2.Ifweknowthemaximumgainoftheantennaandthetotalpower inputtotheantenna,throughthecalculation,wewillknowthedistancerwheretheMPElimitis reached. 2.TestProcedure SoftwareprovidedbyclientenabledtheEUTtotransmitandreceivedataatlowest,middleandhighest channelindividually. Page2 of 2ReportNo.: FCS202203123W0 2 Flux ComplianceServiceLaboratory Room105 Floor Bao hao TechnologyBuilding1 NO.15Gong ye West Road Hi-TechIndustrial,Song shan lake Dongguan Tel: 769-27280901Fax:769-27280901http://www.FCS-lab.com 3. Test Resultof RF ExposureEvaluation Outputpower (dBm/mW) Antenna Gain(dBi) PowerDensity at R=20cm (mW/cm 2 ) Limit (mW/cm 2 ) Result 802.11b3.76 /2.37681.00. 000601.0Pass 802.11g3.68/2.33351.00.0 00581.0Pass 802.11n(20MHz)3.52 /2.24911.00.0 00561.0Pass 802.11n(40MHz)3.94 /2.47741.00.0 00621.0Pass Turn-uppower ModePeakpowerrange(dBm) WIFI2.00-4.00 WIFI Outputpower (dBm/mW) Antenna Gain(dBi) PowerDensity at R=20cm (mW/cm 2 ) Limit (mW/cm 2 ) Result 4.0/2.51191.00. 000631.0Pass
FCCTestReport ReportNo:FCS202203123W01 Issuedfor Applicant: ZHONGSHANGUZHENYESHENGLIGHTING FACTORY Address: F.3,NO.38xinxingeastroad,Guzhengtown, Zhongshancity,Guangdongprovince,China ProductName: ceilingfanlight BrandName: N/A ModelName: 2048 SeriesModel: 2005/2019/2022/744/2002/2001/2034/Y003/ 753/729/731/2045/733/C075/C076/C077/712/ 739 FCCID: 2A5ZW-2048 IssuedBy:FluxComplianceServiceLaboratory Add:Room105FloorBaohaoTechnologyBuilding1NO.15GongyeWestRoad Hi-TechIndustrial,SongshanlakeDongguan Tel:769-27280901Fax:769-27280901http://www.FCS-lab.com Page 2 of61ReportNo.:FCS202103123W01 FluxComplianceServiceLaboratory Room105FloorBaohaoTechnologyBuilding1NO.15GongyeWestRoadHi-TechIndustrial,SongshanlakeDongguan Tel:769-27280901Fax:769-27280901http://www.FCS-lab.com TESTRESULTCERTIFICATION Applicant’sName......................:ZHONGSHANGUZHENYESHENGLIGHTINGFACTORY Address......................................: F.3,NO.38xinxingeastroad,Guzhengtown,Zhongshancity, Guangdongprovince,China Manufacture'sName................:ZHONGSHANGUZHENYESHENGLIGHTINGFACTORY Address......................................: F.3,NO.38xinxingeastroad,Guzhengtown,Zhongshancity, Guangdongprovince,China ProductDescription ProductName...........................: ModelName..............................: SeriesModel..............................: TestStandards..........................: TestProcedure .......................... : ceiling fan light 2048 2005 / 2019 / 2022 / 744 / 2002/2001 / 2034 / Y003 / 753 / 729/731 / 2045 / 733 / C075 / C076/C077 / 712 / 739 FCC Rules and Regulations Part 15 Subpart C, Section 247 ANSI C63.10-2013 ThisdevicedescribedabovehasbeentestedbyFluxComplianceServiceLaboratory,thetest resultsshowthattheequipmentundertest(EUT)isincompliancewiththeFCCrequirements.Andit isapplicableonlytothetestedsampleidentifiedinthereport. Thisreportshallnotbereproducedexceptinfull,withoutthewrittenapprovalofFluxCompliance ServiceLaboratory,thisdocumentmaybealteredorrevisedbyFluxComplianceService Laboratory,personalonly,andshallbenotedintherevisionofthedocument.. DateofTest .................................. : Date(s)ofperformanceoftests . :19Mar,2022~28Mar,2022 DateofIssue.................................:28Mar,2022 TestResult.....................................:Pass Testedby: (ScottShen) Reviewedby : (DukeQian) Approvedby: ( JackWang ) Page 3 of61ReportNo.:FCS202103123W01 FluxComplianceServiceLaboratory Room105FloorBaohaoTechnologyBuilding1NO.15GongyeWestRoadHi-TechIndustrial,SongshanlakeDongguan Tel:769-27280901Fax:769-27280901http://www.FCS-lab.com TableofContentsPage 1.SUMMARYOFTESTRESULTS6 1.1TESTFACTORY7 1.2MEASUREMENTUNCERTAINTY7 2.GENERALINFORMATION8 2.1GENERALDESCRIPTIONOFTHEEUT8 2.2BLOCKDIGRAMSHOWINGTHECONFIGURATIONOFSYSTEMTESTED10 2.3DESCRIPTIONOFNECESSARYACCESSORIESANDSUPPORTUNITS11 2.4EQUIPMENTSLIST12 3.6DBBANDWIDTH13 3.1LIMIT13 3.2TESTPROCEDURE13 3.3TESTSETUP13 3.4TESTRESULTS14 4CONDUCTEDOUTPUTPOWER21 4.1LIMIT21 4.2TESTPROCEDURE21 4.3TESTSETUP21 4.5TESTRESULTS21 5.POWERSPECTRALDENSITY22 5.1LIMIT22 5.2TESTPROCEDURE22 5.3TESTSETUP22 5.5TESTRESULTS23 5.6ORIGINALTESTDATA24 6.BANDEDGEANDSPURIOUS(CONDUCTED)30 6.1LIMIT30 6.2TESTPROCEDURE30 6.3TESTSETUP30 6.5TESTRESULTS31 6.5ORIGINALTESTDATA31 7RADIATEDEMISSIONMEASUREMENT43 8CONDUCTEDEMISSIONTEST57 Page 4 of61ReportNo.:FCS202103123W01 FluxComplianceServiceLaboratory Room105FloorBaohaoTechnologyBuilding1NO.15GongyeWestRoadHi-TechIndustrial,SongshanlakeDongguan Tel:769-27280901Fax:769-27280901http://www.FCS-lab.com TableofContentsPage 9.ANTENNAREQUIREMENT61 9.1STANDARDREQUIREMENT61 9.2RESULT61 Page 5 of61ReportNo.:FCS202103123W01 FluxComplianceServiceLaboratory Room105FloorBaohaoTechnologyBuilding1NO.15GongyeWestRoadHi-TechIndustrial,SongshanlakeDongguan Tel:769-27280901Fax:769-27280901http://www.FCS-lab.com RevisionHistory Rev.IssueDateEffectPageContents 0028Mar,2022AllInitialIssue Page 6 of61ReportNo.:FCS202103123W01 FluxComplianceServiceLaboratory Room105FloorBaohaoTechnologyBuilding1NO.15GongyeWestRoadHi-TechIndustrial,SongshanlakeDongguan Tel:769-27280901Fax:769-27280901http://www.FCS-lab.com 1.SUMMARYOFTESTRESULTS Testproceduresaccordingtothetechnicalstandards: KDB558074D0115.247MeasGuidancev05r02 FCCPart15.247,SubpartC Standard Section TestItemJudgmentRemark FCC15.247(a)(2)6dBBandwidthPASS-- FCC15.247(b)(3)ConductedOutputPowerPASS-- FCC15.247(e)PowerSpectralDensityPASS-- FCC15.247(d) Band-edgeandSpuriousEmissions (Conducted) PASS-- FCC15.247(d) FCC15.209 FCC15.205 RadiatedSpuriousEmissions PASS-- FCC15.247(d) FCC15.209 FCC15.205 RadiatedBandEdgeCompliance PASS-- FCC15.207 PowerLineConductedEmission PASS-- FCC15.203Antennarequirement PASS-- 15.205RestrictedBandEdgeEmissionPASS-- NOTE: (1)”N/A”denotestestisnotapplicableinthisTestReport (2)AlltestsareaccordingtoANSIC63.10-2013 Page 7 of61ReportNo.:FCS202103123W01 FluxComplianceServiceLaboratory Room105FloorBaohaoTechnologyBuilding1NO.15GongyeWestRoadHi-TechIndustrial,SongshanlakeDongguan Tel:769-27280901Fax:769-27280901http://www.FCS-lab.com 1.1TESTFACTORY CompanyName:FluxComplianceServiceLaboratory Address: Room105FloorBaohaoTechnologyBuilding1NO.15Gongye WestRoadHi-TechIndustrial,SongshanlakeDongguan Telephone:+86-769-27280901 Fax:+86-769-27280901 FCCTestFirmRegistrationNumber:514908 Designationnumber:CN0127 A2LAaccreditationnumber:5545.01 1.2MEASUREMENTUNCERTAINTY Thereporteduncertaintyofmeasurementy±U,whereexpendeduncertaintyUisbasedona standarduncertaintymultipliedbyacoveragefactorofk=2,providingalevelofconfidenceof approximately95%. No.ItemUncertainty 1RFoutputpower,conducted±0.71dB 2UnwantedEmissions,conducted±2.988dB 3ConductedEmission(9KHz-150KHz) ±4.13dB 4ConductedEmission(150KHz-30MHz) ±4.74dB 5Allemissions,radiated(<1G)30MHz-1000MHz ±5.2dB 6Allemissions,radiated1GHz-18GHz±4.66dB 7Allemissions,radiated18GHz-40GHz±4.31dB Page 8 of61ReportNo.:FCS202103123W01 FluxComplianceServiceLaboratory Room105FloorBaohaoTechnologyBuilding1NO.15GongyeWestRoadHi-TechIndustrial,SongshanlakeDongguan Tel:769-27…
Text truncated - open the document above for the full version.
Page1of2ReportNo.:FCS202203123 Blow1GHzforradiatedemissiontestsetup Above1GHzforradiatedemissiontestsetup Page2of2ReportNo.:FCS202203123 Conductedemissiontestsetup
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 2.41 GHz - 2.46 GHz | 2.48 mW |