Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
Electrical Information & Installation Instructions Contact: [email protected] 1108 Eldridge St, Clearwater, FL 33755 For further information visit www.aquaamp.com The product must be installed according to the specified instructions. Failure to comply may result in personal injury, vessel/vehicle damage, and/or product failure. Installation by a trained electrician is recommended by AquaAmp. Damage and/or injuries caused by improper installation are not covered by the warranty. WARNING: Only a 12V DC battery/power supply should be used with this device. Before installing, the power supply must be turned off. Between the battery/power supply and the product, an appropriate fuse or circuit breaker must be utilized. Before turning on the electricity, double-check that all wiring is polarized correctly. High voltages may be included in this product. Do not alter the product in any way. This product is not intended for use in potentially hazardous or flammable environments. Do not install in a hazardous/flammable environment, such as engine rooms. Make sure the space behind the mounting point is clear of wires, fuel, and any other potentially hazardous things before drilling any holes. Ensure that any holes cut do not considerably degrade the surface's structure. If the product must be installed outside, it must be installed safely above the waterline and not in danger of being submerged. A metallic surface prevents the product from charging. CAUTION: The item is designed to charge Qi compatible devices only. The cable must be kept in place and not obstruct mechanical systems. There are no user-serviceable components in this product. In no way attempt to repair or modify the product. The device's high friction top surface does not guarantee that it will not slip during strong acceleration and deceleration working situations. A phone case thicker than 3mm may prevent the smartphone from charging. The product may temporarily shut down if used in a hot environment or in direct sunlight; this is a safety feature of the electronics. The IP rating is only valid if the instructions are followed correctly. Avoid mounting near heat-radiating appliances and in poorly ventilated spaces when choosing a placement. EMC INSTALLATION GUIDELINES: To ensure that electromagnetic interference between equipment is minimized, AquaAmp devices comply with Electromagnetic Compatibility (EMC) requirements. To keep electromagnetic interference to a bare minimum, proper installation is essential. WIRING: When extending the wire from your battery/power source to the product, make sure there is a continuous supply of at least 10V. For any length of cable extension, we recommend an 18AWG (0.82mm 2 ) wire gauge. This diagram shows how the product should be linked to a 12V or 24V DC battery or power supply. ENVIRONMENTAL PROTECTION: Electrical trash should not be thrown out with household garbage. Please recycle wherever possible. For recycling advice, contact your local government or a merchant. IMPORTANT: AquaAmp LLC disclaims all liability for any injuries or other damages resulting from the use of their products in any situation. WARRANTY: The non-transferable 2-year warranty covers only this AquaAmp product and not any devices mounted in or on it. Users' devices are not covered by a guarantee, and they subject them to known and unknown hazards at their own risk. FCC WARNING : AquaAmp LLC certifies that this product complies with the EMC CE-RED Directive (2014/53/EU) and the EN 62368 standard. The CE compliance This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: —Reorient or relocate the receiving antenna. —Increase the separation between the equipment and receiver. —Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. —Consult the dealer or an experienced radio/TV technician for help. Note: The Grantee is not responsible for any changes or modifications not expressly approved by the party responsible for compliance. such modifications could void the user's authority to operate the equipment. The device has been evaluated to meet general RF exposure requirement. This equipment complies with FCC's RF radiation exposure limits set forth for an uncontrolled environment. This device and its antenna(s) must not be co-located or conjunction with any other antenna or transmitter. The device has been evaluated to meet general RF exposure requirement. To maintain compliance with FCC's RF exposure guidelines, the distance must be at least 20 cm between the radiator and your body, and fully supported by the operating and installation configurations of the transmitter and its antenna(s). certificate can be accessed at aquaamp.com. Installation Instructions: Core/CoreX Pro charger Parts Provided Wireless Charger 2.5” Hole Saw Electric Drill Installation Guide Step 1: Drill or Cut 2.5” hole. Tools Required Step 2: Use an alcohol wipe to clean application surface. Remove adhesive backi…
Text truncated - open the document above for the full version.
AQUA-AMP,LLC Address:1108ELDRIDGEST,CLEARWATER,FL33755,USA Date:2025-09-29 FederalCommunicationsCommission AuthorizationandEvaluationDivision 7435OaklandMillsRoad Columbia,MD21046 Ref:AttestationStatementsPart2.911(d)(7)Filing SUBJECT:FCCApplicationforFCCID:2A64N-P1046A-1 FRN:0032457442 (“AQUA-AMP,LLC”)certifiesthat,asofthedateofthefilingoftheapplication,AQUA-AMP, LLCisourdesignatedU.S.agentforserviceofprocessfortheabovereferencedFCCID. (“AQUA-AMP,LLC”)acceptstomaintainanagentfornolessthanoneyearafterthegrantee hasterminatedallmarketingandimportationortheconclusionofanyCommission-related proceedinginvolvingtheequipment. AQUA-AMP,LLCaccepts,asofthedateofthefilingoftheapplication,theobligationofthe designatedU.S.agentforserviceofprocessfortheabovereferencedFCCID. DesignatedU.S.AgentInformation: Name:AQUA-AMP,LLC Address:1108ELDRIDGEST,CLEARWATER,FL33755,USA FRN:0032457442 ContactPerson:TsaeWu Tel.:(714)635-6350 Email:[email protected] Sincerely, Signedonbehalfof(AQUA-AMP,LLC) SignedonbehalfofAQUA-AMP,LLC Name:TsaeWuName:TsaeWu Title:InternationalPurchaserTitle:InternationalPurchaser Date:2025-09-29Date:2025-09-29
Rev1/26/2023 (AQUA-AMP,LLC) FederalCommunicationsCommission AuthorizationandEvaluationDivision 7435OaklandMillsRoad Columbia,MD21046 USA Date:09-28-2025 Ref:AttestationStatementsPart2.911(d)(5)(i)Filing FCCID:2A64N-P1046A-1 (“AQUA-AMP,LLC”)certifiesthattheequipmentforwhichauthorizationissoughtisnot“covered” equipmentprohibitedfromreceivinganequipmentauthorizationpursuanttosection2.903oftheFCC rules. (“AQUA-AMP,LLC”)certifiesthattheequipmentforwhichauthorizationissoughtdoesnotinclude cybersecurityoranti-virussoftwareproducedorprovidedbyKasperskyLab,Inc.oranyofitssuccessors andassignees,includingequipmentwithintegratedKasperskyLab,Inc.(oranyofitssuccessorsand assignees)cybersecurityoranti-virussoftwarepursuanttoDA-24-886andKDB986446D01Covered EquipmentGuidancesectionB(2a). Deviceisinherentlycompliantbasedonhardwarelimitationsorsoftwarecontrols. or ASoftwareBillofMaterials(SBOM)isprovidedtotheTCBforreview,and Theend-userorthirdpartiescannotinstalladditionalsoftwareonthisdevice. Sincerely, (Applicantsignature): (Applicantprintedname):TsaeWu Rev1/26/2023 (AQUA-AMP,LLC) FederalCommunicationsCommission AuthorizationandEvaluationDivision 7435OaklandMillsRoad Columbia,MD21046 USA Date:09-28-2025 Ref:AttestationStatementsPart2.911(d)(5)(ii)Filing FCCID:2A64N-P1046A-1 (“AQUA-AMP,LLC”)certifiesthat,asofthedateofthefilingoftheapplication,AQUA-AMP,LLCisnot identifiedontheCoveredList(asaspecificallynamedentityoranyofitssubsidiariesoraffiliates)asan entityproducing“covered”equipment. Sincerely, (Applicantsignature): (Applicantprintedname):TsaeWu
Product Specification Book Specification Number 20250901001 Effective Date 2025/9/1 Customer NameShenzhen Xinlang Technology Co., Ltd. Product typeBare copper coil Bojun Part NumberTD-BJ20241118001-42.5L=10MM Customer part number DXQ22.0213 【 □ New edition release , □ Version revision】 【 本规范含目录共 3页 】【 RoHS Compliant Parts 】 CompileReviewApproval Xiao ShufangPeng YongZhu Hui Anfu County Bojun Electronics Co., Ltd. This acknowledgement form must be signed and returned by the customer within 30 days of receipt. Failure to do so will be regarded as following the terms of this acknowledgement form when the production is carried out. 【 Customer approval 】 Date : Acknowledgment status : □Fully acknowledge □Conditional approval □Refuse to admit ApprovalReview Re-examination Check Explanation: √√ Product Specification Book Customer Name Shenzhen Xinlang Technology Co., Ltd. Customer part number DXQ022.0213 Bojun Part Number TD-BJ20241118001-42.5 L=10MM Specification Number 20250901001 发行/修订记录/Release/Revision History VersionEffective DateChange content / reasonApproval 0012025/9/1 New specification release CompileReviewApproval Xiao Shufang Peng Yong Zhu Hui Product Specification Book Customer NameShenzhen Xinlang Technology Co., Ltd. Customer part number DXQ22.0213 Bojun Part Number TD-BJ20241118001-42.5L=10MM Specification Number 20250901001 Version 001 ♦、Dimensions of the shape (Organization: mm) A42.5 max B38.5 ±0.5 C21.0 ±0.5 D 5.3 E10.0 ref F3 ±1 G2.4Max H10.0 ±2 I J 0.80 ±0.1(Thickness of the magnetic disk) (1) Wire diameter : 0.08*80P (2)Number of turns in the coil:11TS (3) Do the end lines intersect : yes 4MM Coiled High-Temperature Adhesive Tape The coil and the magnetic sheet need to be adhered in the center. (4) (5) (6) ♦、Electrical characteristics (7) To pass the test, you need one 15mm and one 8mm casing. : (7) ParametersSpecificationTest conditions Testing instrumen Add a 0.8-sized small magnet in the middle. t L08.1±10%μH100KHz/1V■TH1816B Q>60 min100KHz/1V■TH1816B DCR<50mΩ@ 25°C■CH-502BC ♦、Temperature grade: Operating temperature -40°C~ 125°C ♦、Material List: Serial Number Product Name SupplierNote 1 Magnetic sheet PC95Manganese zinc 2 Copper wire without insulatio Copper wire n 3 Environmental protection tape 4Ti Copperwire n Qiandao Environmental Protection Tin 5Gel Environmental-friendly glu Material specifications 42.5*5.3*0.8T 0.08*80P 4MM 107H Yellow glue e 6 Gel CompileReviewApproval Xiao ShufangPeng YongZhu Hui Stick 415 white adhesive on the back of the magnetic sheet and do not stick it near the ears.
AQUA-AMP,LLC Date:September29,2025 ProductModelNumber:P1046A-1,P1047A-1 FCCID:2A64N-P1046A-1 Towhomitmayconcern, Re:ProductCertificationRepresentativeAuthorizationLetter WeauthorizeQAILaboratoriesLtd.3980NorthFraserWay,BurnabyB.C. CanadaV5J5K5toactonourbehalfonallmattersconcerningtheabove namedequipment. Thisshallincludethefollowing: Testing Approvalapplicationsandprocedures WedeclarethatQAILaboratoriesLtd.isallowedtoforwardallinformation relatedtotheapprovalprojecttotheappliedcertificationbodyandtothe notificationentitiesandtodiscussanyissuesconcerningtheapproval application.AnyandallactscarriedoutbyQAILaboratoriesLtd.onour behalfshallhavethesameeffectasactsofourown. By: ContactListedonFCCWesbite Title:InternationalPurchaser Email:[email protected] Telephone:(714)635-6350 Onbehalfof:AQUA-AMP,LLC
AQUA-AMP,LLC OfficeofEngineeringTechnology FederalCommunicationsCommission 7435OaklandMillsRoad Columbia,MD21046 USA Date:September29,2025 Subject;RequestforConfidentiality FCCID:2A64N-P1046A-1 ToWhomItMayConcern, PursuanttotheprovisionsoftheCommission’srulesTitle47Sections§0.457and§0.459,we arerequestingtheCommissiontowithholdthefollowingattachment(s)asconfidential documentsfrompublicdisclosureindefinitely. Thesedocumentscontaindetailedsystemandequipmentdescriptionsandareconsideredas proprietaryinformationinoperationoftheequipment.Thepublicdisclosureofthese documentsmightbeharmfultoourcompanyandwouldgivecompetitorsanunfairadvantage inthemarket. SchematicDiagram BlockDiagram PartsList OperationalDescription Tune-upProcedure SoftwareSecurityRequirementsforUNIIdevices Inadditionaltoabovementioneddocuments,inordertocomplywiththemarketingregulations inTitle47CFR§2.803andtheimportationrulesinTitle47CFR§2.1204,whileensuringthat businesssensitiveinformationremainsconfidentialuntiltheactualmarketingofnewly authorizeddevices,werequestShortTermConfidentialityofthefollowingattachment(s); ExternalPhotos TestSetupPhotos InternalPhotos UserManual For45days,pursuanttoPublicNoticeDA04-1705. OR For180dayspursuanttoKDB726920D01. Itisourunderstandingthatallmeasurementtestreports,FCCIDlabelformatand correspondenceduringthecertificationreviewprocesscannotbegrantedasconfidential documentsandthisinformationwillbeavailableforpublicreviewoncethegrantofequipment authorizationisissued. Sincerely, Signature: Name:TsaeWu Title:InternationalPurchaser
AQUA-AMP,LLC ModelDifference Date:2025-09-29 Productdescription:Core/CoreXProCharger Modelname:P1046A-1,P1047A-1 FCCID:2A64N-P1046A-1 P1046A-1istestedmodel,othermodelsarederivativemodels.Themodelsare identicalincircuit,onlydifferentonthemodelnames.SothetestdataofP1046A-1 canrepresenttheremainingmodels. Client’ssignature: Client’sname/title:TsaeWu/InternationalPurchaser Contactinformation/address:1108ELDRIDGEST,CLEARWATER,FL33755,USA
FCCID:2A64N-P1046A-1 EUTPHOTO(ExternalPhotos) FCCID:2A64N-P1046A-1 FCCID:2A64N-P1046A-1 ※※※※※ENDOFREPORT※※※※※
Size:2mmX10mm FCCID:2A64N-P1046A-1
FCCID:2A64N-P1046A-1 EUTPHOTOS(InternalPhotos) FCCID:2A64N-P1046A-1 FCCID:2A64N-P1046A-1 FCCID:2A64N-P1046A-1 FCCID:2A64N-P1046A-1 ※※※※※ENDOFREPORT※※※※※ ANT
Page 1 of 5 FCCID:2A64N-P1046A-1 ProductName:Core/CoreXProCharger ProductModelNo.: P1046A-1,P1047A-1 ModelDifference: P1046A-1istestedmodel,othermodelsarederivativemodels.Themodels areidenticalincircuit,onlydifferentonthemodelnames.Sothetestdataof P1046A-1canrepresenttheremainingmodels. TestAuxiliary:ACAdapterandMobilephone Transmittingmode:KeeptheEUTincontinuouslywirelesschargingmode Powersupply: Input:12V3A Output:25WMax TestModes: Mode1 ACAdapter+Wirelesschargingload(MPPProtocol:25W) Mode2 ACAdapter+Wirelesschargingload(MPPProtocol:15W) Mode3 ACAdapter+Wirelesschargingload(MPPProtocol:10W) Mode4 ACAdapter+Wirelesschargingload(MPPProtocol:7.5W) Mode5 ACAdapter+Wirelesschargingload(MPPProtocol:5W) Mode6ACAdapter+Mobilephonecharging(EPPProtocol:BatteryStatus:≤1%) Mode7ACAdapter+Mobilephonecharging(EPPProtocol:BatteryStatus:50%) Mode8ACAdapter+Mobilephonecharging(EPPProtocol:BatteryStatus:≥98%) Mode9Standby Note:Allmodesweretested,onlytheworst-casewasrecordedinthereport.Mode1istheworstmode. Auxiliaryequipment ItemEquipmentMfr/BrandModel/TypeNo.SeriesNo.Note 1MobilephoneXiaomiCommunicationsCo.,Ltd.Xiaomi12SProN/AN/A 2MobilephoneAppleInc.iPhone16PULSN/AN/A Page 2 of 5 1MeasuringStandard KDB680106D01WirelessPowerTransferv04andPart2.1091 2Requirements Accordingtotheitem5ofKDB680106D01v04: Inductivewirelesspowertransferapplicationsthatmeetallofthefollowingrequirementsareexcludedfrom submittinganRFexposureevaluation. Requirementsofsection3ofKDB680106D01Yes/NoDescription MobileDeviceandPortableDeviceConfigurationsYesMobileDevice EquipmentAuthorizationProceduresforDevicesOperatingat FrequenciesBelow4MHz Yes Thedeviceoperateinthe frequencyrange:110.1-205kHz, 360kHz RFExposurecompliancemaybeensuredonlyforaminimum conditionsatsmallerdistancescanstillbeconsidered unlikely.separationdistancethatisgreaterthan20cm,whileuse Yes TheEUTH-fieldandE-field strengthsat20cmsurrounding thedevice. Limits Thecriterialistedinthefollowingtableshallbeusedtoevaluatetheenvironmentimpactofhumanexposure toradiofrequency(RF)radiationasspecifiedin1.1307(b) LimitsforMaximumPermissibleExposure(MPE) Page 3 of 5 3TestSetup 4TestProcedure 1)TheRFexposuretestwasperformedinanechoicchamber. 2)Themeasurementprobewasplacedattestdistance(20cmfromallsidesand20cmfromthetop)whichis betweentheedgeofthechargerandthegeometriccenterofprobe. 3)Thehighestemissionlevelwasrecordedandcomparedwithlimitassoonasmeasurementofeachpoints (A,B,C,D,E,F)werecompleted. 4)TheEUTwasmeasuredaccordingtothedictatesofKDB680106D01v04. Remark:TheEUT’stestpositionA,B,C,D,EandFisvalidfortheEandHfieldmeasurements. 5MEASUREMENTUNCERTAINTY Thereporteduncertaintyofmeasurementy±U,whereexpendeduncertaintyUisbasedonastandard uncertaintymultipliedbyacoveragefactorofk=2,providingalevelofconfidenceofapproximately95%. No.ItemUncertainty 1E-field14.72% 2H-field15.48% 3Temperature±0.5°C 4Humidity±2% DecisionRule Uncertaintyisnotincluded Uncertaintyisincluded Page 4 of 5 6TestInstrumentslist TestEquipmentManufacturerModelNo.SN. Cal.Date (mm-dd-yy) Cal.Duedate (mm-dd-yy) Near-fieldElectricand ElectricFieldSensor System SPEAG MAGPy- 8H3D+ED3 V2 3080November15,2023November14,2025 Testsoftware:MAGPY.exeV2.6 7TestResult E-FiledStrengthat20cmfromtheedgessurroundingtheEUT(V/m) Frequency Range(MHz) Test Position A Test Position B Test Position C Test Position D Test Position E Test Position F 50%Limits (V/m) Limits (V/m) test result 0.111-0.2050.560.540.540.480.500.56307614PASS H-FiledStrengthat20cmfromtheedgessurroundingtheEUT(A/m) Frequency Range(MHz) Test Position A Test Position B Test Position C Test Position D Test Position E Test Position F 50%Limits (A/m) Limits (A/m) test result 0.111-0.2050.170.140.140.170.120.170.8151.63PASS Page 5 of 5 TestPhoto ***Endofreport***
ProjectNo.:ZHT-250826104W02 Page 1 of 20 Intheconfigurationtested,theEUTcompliedwiththestandardsspecifiedabove. PreparedbyReviewedby: Approvedby: LeonLi/EngineerBaretWu/DirectorLeviLee/Manager Note:ThisdevicedescribedabovehasbeentestedbyZHT,andthetestresultsshowthattheequipment undertest(EUT)isincompliancewiththeFCCrequirements.Anditisapplicableonlytothetestedsample identifiedinthereport.Thisreportshallnotbereproducedexceptinfull,withoutthewrittenapprovalofZHT, thisdocumentmaybealteredorrevisedbyZHT,personalonly,andshallbenotedintherevisionofthe document. FCCTESTREPORT FCCID:2A64N-P1046A-1 ReportNo........................: ZHT-250826104W02 Product............................: Core/CoreXProCharger Trademark.......................: Aqua-Amp Model(s)...........................: P1046A-1,P1047A-1 ModelDifference..............: P1046A-1istestedmodel,othermodelsarederivativemodels.Themodels areidenticalincircuit,onlydifferentonthemodelnames.Sothetestdataof P1046A-1canrepresenttheremainingmodels. Applicant..........................: AQUA-AMP,LLC Address............................: 1108ELDRIDGEST,CLEARWATER,FL33755,USA Manufacturer....................: AQUA-AMP,LLC Address............................: 1108ELDRIDGEST,CLEARWATER,FL33755,USA Preparedby.....................: GuangdongZhonghanTestingTechnologyCo.,Ltd. Address............................: Room104/201,Building1,YibaolaiIndustrialPark,Qiaotou,FuhaiSubdistrict, Bao'anDistrict,Shenzhen,Guangdong,China DateofReceipt................: Aug.26,2025 DateofTest(s)................: Aug.26,2025toSept.23,2025 DateofIssue....................: Sept.23,2025 Standard..........................................::FCCCFRTitle47Part15SubpartC Testprocedure................................::/ ProjectNo.:ZHT-250826104W02 Page 2 of 20 TABLEOFCONTENTS 1.VERSION..................................................................................................................................................3 2.TESTSUMMARY......................................................................................................................................4 3.GENERALINFORMATION......................................................................................................................5 3.1GENERALDESCRIPTIONOFEUT...................................................................................................5 3.2Testmode...........................................................................................................................................5 3.3BlockDiagramofEUTConfiguration..................................................................................................6 3.4TestConditions...................................................................................................................................6 3.5DescriptionOfSupportUnits(ConductedMode)...............................................................................6 4.TAESTFACILITYANDTESTINSTRUMENTUSED..............................................................................7 4.1TESTFACILITY..................................................................................................................................7 4.2EQUIPMENTSLISTFORALLTESTITEMS.....................................................................................7 4.3TESTINGSOFTWARE.......................................................................................................................8 5.CONDUCTEDEMISSIONTEST............................................................................................................10 5.1CONDUCTEDEMISSIONMEASUREMENT...................................................................................10 5.1.1POWERLINECONDUCTEDEMISSIONLimits...........................................................................10 5.1.2TESTPROCEDURE......................................................................................................................10 5.1.3DEVIATIONFROMTESTSTANDARD.........................................................................................10 5.1.4TESTSETUP.................................................................................................................................11 5.1.5EUTOPERATINGCONDITIONS..................................................................................................11 5.1.6TestResult.....................................................................................................................................11 6.RADIATEDEMISSIONMEASUREMENT..............................................................................................12 6.1RadiatedEmissionLimits..................................................................................................................12 6.2AnechoicChamberTestSetupDiagram..........................................................................................13 6.3TestProcedure.................................................................................................................................13 6.4DEVIATIONFROMTESTSTANDARD............................................................................................13 6.5TestResult........................................................................................................................................14 7.BANDWIDTHTEST................................................................................................................................17 8.ANTENNAREQUIREMENT...................................................................................................................19 9.TESTSETUPPHOTO............................................................................................................................20 10.EUTCONSTRUCTIONALDETAILS....................................................................................................20 ProjectNo.:ZHT-250826104W02 Page 3 of 20 1.VERSION ReportNo.VersionDescriptionApproved ZHT-250826104W02Rev.01Ini…
Text truncated - open the document above for the full version.
FCCID:2A64N-P1046A-1 EUTTESTPHOTOS ※※※※※ENDOFREPORT※※※※※
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 0.1101 MHz - 0.205 MHz | - |
| 2 | 15C | 0.36 MHz - 0.36 MHz | - |

AquaAmp Wireless Charger
Equipment Class
DCD - Part 15 Low Power Transmitter Below 1705 kHz