FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Infocar Co., Ltd./
  3. 2A66X-IO180-SH

2A66X-IO180-SHSmart Scanner

Infocar Co., Ltd.
Smart Scanner - FCC ID 2A66X-IO180-SH - Infocar Co., Ltd.
Click to zoom

Application Details

Equipment Class
DTS - Digital Transmission System
Date of Grant
Apr 10, 2023
Application Purpose
Original Equipment
Date of Application
Apr 10, 2023
Equipment Note
Smart Scanner
Frequency Range
2402.00000000 - 2480.00000000
Company
Infocar Co., Ltd.
Country
South Korea

Documents & Files

Select a file to view

Users Manual

↗

Attestation Statements

↗
↗

Cover Letter(s)

↗
↗
↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗
↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

Name of Equipment : Smart Scaner Model : IO180-SH Manufacturer : Infocar Co., Ltd. FCC ID : 2A66X-IO180-SH IC : 30192-IO180SH Connection Type : Bluetooth LE 4.0, Bluetooth Connectable Terminals : Android, iOS smartphone(tablet) Rated Voltage : 12V Operating Temperature : -20°C -- 70°C Weight : 17g Size : 49x26x23mm Date of manufacturing : NOV. 2022 Customer Center : +82-70-7708-6118 / [email protected] Made in China FCC INTERFERENCE STATEMENT This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense. FCC COMPLIANCE This device complies with part 15 of the FCC rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) This device must accept any interference received, including interference that may cause undesired operation. FCC RADIATION EXPOSURE STATEMENT This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 20 cm between the radiator and your body. This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter. IC INDUSTRY CANADA STATEMENT This device complies with Industry Canada licence-exempt RSS standard(s). Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device. Le présent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radio exempts de licence. L'exploitation est autorisée aux deux conditions suivantes : (1) l'appareil ne doit pas produire de brouillage, et (2) l'utilisateur de l'appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d'en compromettre le fonctionnement. FCC CAUTION Any changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate this equipment. This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter. IC INDUSTRY CANADA RADIATION EXPOSURE STATEMENT ( Déclaration d’exposition aux radiations ) This equipment complies with IC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 20 cm between the radiator & your body. Cet équipement est conforme aux limites d’exposition aux rayonnements IC établies pour un environnement non con trôlé. Cet équipement doit être installé et utilisé avec un minimum de 20 cm de distance entre la source de rayonnement et votre corps. How to Install When the car is turned off, attach the terminal to OBD socket shown above, and start the car (red LED light is up when installed normally). Fuse box and terminal box should be removed from the cover. If the OBD socket is located on a pedal or other location that you cannot see, please use a flash for installation. Location of OBD socket may vary depending on vehicle’s manufacturer and model. Use a PS2 or less than 100 W power 1. Inside the fuse box, the lower left of the driver's seat 2. Under the driver's seat 3. Audio, socket box under the ashtray (Renault Samsung, Peugeot) 4. Center console or console box Download Application Download Access Google Play Store or App Store and install 'Infocar' Connection Bluetooth Setting Click “Connect” on the top right corner and move to Bluetooth connecting page. [Android] Check Bluetooth or Bluetooth LE 4.0 as a connection type and click Infocar180 in the Bluetooth list below. Type “1234” if a PIN number is required. [iOS] Check Bluetooth LE 4.0 as a connection type and click Infocar180 in the Bluetooth list below. You have to connect through Bluetooth not from the smartphone setting, but from Infocar application. Connection may take time depending on the smartphone OS or model. [AutoRun – Android] 1. Check if you have allowed Infocar to access location. 2. When the engine turns on, Infocar application would be automatically turned on and driving records would be saved. 3. If you can’t autorun Infocar, check if the smartphone and vehicle Bluetooth is well connected. 4. Autorun can be delayed depending on smartphone model. [Connection Failure and How to Solve] 1. Enable smartphone’s Bluetooth 2. Deactivate the battery usage optimization. 3. If the problem repeats after you change the setting, reinstall the application and try again. If the problem persists, please click "Settings→Ask to Developers" in Infocar app. Then we will pleasely help you.

Attestation Statements

Infocar Co., Ltd. Convergence Technology Commercialization Center 6F, 218, Gajeong-ro, Yuseong-gu, Daejeon, Republic of Korea March 31, 2023 Eurofins Electrical and Electronic Testing NA, Inc. 914 West Patapsco Avenue Baltimore, MD 21230 RE: Attestation Statements Part 2.911(d)(5)(i) request for 2A66X-IO180-SH [Infocar Co., Ltd.] (“the applicant”) certifies that the equipment for which authorization is sought is not “covered” equipment prohibited from receiving an equipment authorization pursuant to section 2.903 of the FCC rules. Sincerely, GeonHo Pyo Infocar Co., Ltd. Convergence Technology Commercialization Center 6F, 218, Gajeong-ro, Yuseong-gu, Daejeon, Republic of Korea March 31, 2023 Eurofins Electrical and Electronic Testing NA, Inc. 914 West Patapsco Avenue Baltimore, MD 21230 RE: Attestation Statements Part 2.911(d)(5)(ii) request for 2A66X-IO180-SH [Infocar Co., Ltd.] (“the applicant”) certifies that, as of the date of the filing of the application, the applicant is not identified on the Covered List as an entity producing “covered” equipment. Sincerely, GeonHo Pyo

Attestation Statements

V02072023 Infocar Co., Ltd. Convergence Technology Commercialization Center 6F, 218, Gajeong-ro, Yuseong-gu, Daejeon, Republic of Korea Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 USA Date: 03/29/23 Ref: Attestation Statement Part 2.911(d)(7) Filing Validity Period: Permanent FCC ID: 2A66X-IO180-SH Manufacturer Name Infocar Co., Ltd. Address Grantee Code FRN Convergence Technology Commercialization Center 6F, 218, Gajeong-ro, Yuseong-gu, Daejeon, Republic of Korea 2A66X 0032478208 certifies that, as of the dates of this application, Americas Compliance Consulting LLC dba iCertifi “iCertifi” is our designated U.S. agent for service of process for the above referenced FCC ID. We accept to maintain an agent for no less than one year after the grantee has terminated all marketing and importation or the conclusion of any commission-related proceeding involving the equipment. The US Agent for Service of Process is aware of and agrees to comply with the requirements outlined in the FCC Equipment Authorization Program, Report and Order FCC 22-84, and clause § 2.911. iCertifi accepts, as of the date of the filing of the application, the obligation of the designated U.S. agent for service process for the above: Designated U.S. Agent Information: Name Americas Compliance Consulting, LLC dba iCertifi FCC FRN 0033399411 Address 1001 SW Disk Drive, Suite 250 Bend, Oregon 97702 USA Contact Person Paul Preston Telephone (866) 885-4575 Email [email protected] Sincerely, Infocar Co., Ltd. Americas Compliance Consulting LLC dba iCertifi GeonHo Pyo Paul Preston V02072023

Cover Letter(s)

Infocar Co., Ltd. Convergence Technology Commercialization Center 6F, 218, Gajeong-ro, Yuseong-gu, Daejeon, Republic of Korea Date: March 30, 2023 Eurofins Electrical and Electronic Testing NA, Inc. 914 West Patapsco Avenue Baltimore, MD 21230 RE: CONFIDENTIALITY REQUEST FOR (Smart Scanner / IO180-SH AND 2A66X- IO180-SH) To Whom It May Concern: This letter serves as an official request for confidentiality under sections 0.457 and 0.459 of CFR 47. We have requested that the (below list) required to be submitted with this application be permanently withheld from public review. Permanent Confidential Request -. Schematics -. Block Diagram -. Operational Description SPECIFY REASON FOR REQUEST (i.e. the above documents are company proprietary information that could never get into the possession of your competition). Please contact me if there is any information you may need. Sincerely, GeonHo Pho / Team Leader

Cover Letter(s)

Infocar Co., Ltd. Convergence Technology Commercialization Center 6F, 218, Gajeong-ro, Yuseong-gu, Daejeon, Republic of Korea Date: March 30, 2023 Eurofins Electrical and Electronic Testing NA, Inc. 914 West Patapsco Avenue Baltimore, MD 21230 RE: CONFIDENTIALITY REQUEST (Smart Scanner / IO180-SH AND 2A66X- IO180SH) To Whom It May Concern: This letter serves as an official request for confidentiality under sections 0.457 and 0.459 of CFR 47. We have requested that the (below list) required to be submitted with this application be short-term Confidentiality f or a period of 180 days after grant is issued. Short-Term Confidential Request -. External Photos -. Internal Photos -. Test set-up photo -. User Manual SPECIFY REASON FOR REQUEST (i.e. These documents contain detailed system and equipment descriptions and related information about the product, which we considers to be proprietary, confidential, and a custom design and otherwise, would not release to the general public. Since this design is a basis from which future technological products will evolve, we feel that this information would be of benefit to our competitors, and that the disclosure of the information in these documents would give our competitors an unfair advantage in the market. Please contact me if there is any information you may need. Sincerely, GeonHo Pho / Team Leader

Cover Letter(s)

Infocar Co., Ltd. Convergence Technology Commercialization Center 6F, 218, Gajeong-ro, Yuseong-gu, Daejeon, Republic of Korea Date: March 30, 2023 Eurofins Electrical and Electronic Testing NA, Inc. 914 West Patapsco Avenue Baltimore, MD 21230 RE: LETTER OF AGENT AUTHORIZATION To Whom It May Concern: We, the undersigned, hereby authorize Ms. Chloe Lee/Deputy General Manager of KCTL Inc to act on our behalf in all matters relating to application for equipment authorization, including the signing of all documents relating to these matters. We also hereby certify that no party to the application authorized hereunder is subject to the denial of benefits, including FCC benefits, pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C.853(a). This agreement expires one year from the current date. Sincerely, GeonHo Pho / Team Leader

Cover Letter(s)

Infocar Co., Ltd. Convergence Technology Commercialization Center 6F, 218, Gajeong-ro, Yuseong-gu, Daejeon, Republic of Korea Tel +82-70-7708-9560/ Fax +82-504-395-7304 Date: March 30, 2023 Dear Sir/Madam, Re: Letter of Similarity We, Infocar Co., Ltd. declare the differences for between original model and variant models. -Product: Smart Scanner -Model name: IO180-SH -Variant Model name : IO180-PH -> The additional model is identical to model IO180-SH except for power switch Sincerely Yours, __________ NAME : GeonHo Pyo TITLE : Team Leader E-MAIL: [email protected] FAX: +82-504-395-7304 Phone: +82-10-7684-8243 Infocar Co., Ltd.

External Photos

This document shall not be reproduced, except in full, without the written approval External photos of EUT This document shall not be reproduced, except in full, without the written approval This document shall not be reproduced, except in full, without the written approval

ID Label/Location Info

<Top View> [Label info.&Location] -Derivative model

Internal Photos

This document shall not be reproduced, except in full, without the written approval Internal photos of EUT This document shall not be reproduced, except in full, without the written approval PCB ANT

RF Exposure Info

This test report shall not be reproduced, except in full, without the written approval * RF Exposure FCC ID: 2A66X-IO180-SH 1. Regulation Regulation This document is prepared to show compliance with the RF Exposure requirements as required in §1.1310 of the FCC rules and Regulations. The limit for Maximum Permissible Exposure (MPE), specified in FCC §1.1310, is listed in Table 1-1. According to FCC §1.1310: the criteria listed in the following table shall be used to evaluate the environmental impact of human exposure to radio-frequency (RF) radiation as specified in §1.1307(b). Table 1 – Limits for Maximum Permissible Exposure (MPE) Frequency Range (㎒) Electric Field Strength [V/m] Magnetic Field Strength [A/m] Power Density [㎽/㎠] Averaging Time [minute] (A) Limits for Occupational / Controlled Exposure 0.3 ~ 3.0 614 1.63 *100 6 3.0 ~ 30 1842/f 4.89/f *900/f 2 6 30 ~ 300 61.4 0.163 1.0 6 300 ~ 1 500 / / f/300 6 1 500 ~ 15 000 / / 5 6 (B) Limits for General Population / Uncontrolled Exposure 0.3 ~ 1.34 614 1.63 *100 30 1.34 ~ 30 824/f 2.19/f *180/f 2 30 30 ~ 300 27.5 0.073 0.2 30 300 ~ 1 500 / / f/1 500 30 1 500 ~ 15 000 / / 1.0 30 f=frequency in ㎒, *= plane-wave equivalent power density Per the guidance of KDB 680106, the E-field and H-field limits shown in the table above are extended down to 100 ㎑ in Appendix C): 1) For test separation distances > 50 ㎜ and < 200 ㎜, the power threshold at the corresponding test separation distance at 100 ㎒ in step b) is multiplied by [1 + log(100/f(㎒))] 2) For test separation distances ≤ 50 ㎜, the power threshold determined by the equation in c) 1) for 50 ㎜ and 100 ㎒ is multiplied by ½ 3) SAR measurement procedures are not established below 100 ㎒. When SAR test exclusion cannot be applied, a KDB inquiry is required to determine SAR evaluation requirements for any SAR test results below 100 ㎒ to be acceptable. This test report shall not be reproduced, except in full, without the written approval 2. Result MPE (Maximum Permissive Exposure) Prediction Predication of MPE limit at a given distance: Equation from page 18 of OET Bulletin 65, Edition 97-01  SPGRRPGS4 4 2  S = power density [㎽/㎠] P = Power input to antenna [㎽] G = Power gain of the antenna in the direction of interest relative to an isotropic radiator R = distance to the center of radiation of the antenna [㎝] RF Exposure Compliance Issue The information should be included in the user’s manual: This appliance and its antenna must not be co-located or operation is conjunction with any other antenna or transmitter. A minimum separation distance of 20 ㎝ must be maintained between the antenna and the person for this appliance to satisfy the RF exposure requirements. Note. 1. The power density P d (5th column) at a distance of 20 ㎝ calculated from the friis transmission Formula is far below the limit of 1 ㎽/㎠. 2. Unequal antenna gains, with equal transmit powers. For antenna gains given by G1, G2, ..., GN ㏈i (i) If transmit signals are correlated, then Directional gain = 10 log[(10G 1 /20 + 10G 2 /20 + ... + 10G N /20)2/NANT] ㏈ i [Note the “20”s in the denominator of each exponent and the square of the sum of terms; the object is to combine the signal levels coherently.] This test report shall not be reproduced, except in full, without the written approval Calculation Result of RF Exposure_Worst case BT Mode Frequency [㎒] Max Tune-up Power [㏈m] Max Tune-up Power [㎽] Ant Gain [㏈i] Power density at 20 ㎝ [㎽/㎠] Limit [㎽/㎠] GFSK 2 402 -7.50 0.18 2.70 0.000 07 1.00 BLE Mode Frequency [㎒] Max Tune-up Power [㏈m] Max Tune-up Power [㎽] Ant Gain [㏈i] Power density at 20 ㎝ [㎽/㎠] Limit [㎽/㎠] BLE/ 1 Mbps/ Packet 37 2 402 -6.00 0.25 2.70 0.000 09 1.00

Test Report

Report No.: BL-SZ2261068-901 Tel: +86-755-66850100 E-mail: [email protected] Page No. 1 / 15 Web: www.titcgroup.com Template No.: TRP-Passive-EN (2022-01-12) Add: Block B, 1/F, Baisha Science and Technology Park, Shahe West Road, Nanshan District, ShenZhen, GuangDong Province, China TEST REPORT Applicant: Shanghai Appropriate Gifts., Ltd Address: Shanghai Fengxian Occurrence of Zhen Jiang Hai nan Road 404 Equipment Type: Automobile diagnostic instrument Model Name: IO180-IH Brand Name: INFOCAR Test Standard: ANSI/IEEE Std 149-1979 Test Date: Jun. 29, 2022 Date of Issue: Jul. 05, 2022 ISSUED BY: Shenzhen BALUN Technology Co., Ltd. Tested by: Mai Jintian Checked by: Tolan Tu Approved by: Wei Yanquan (Chief Engineer) _______________ _______________ _______________ Report No.: BL-SZ2261068-901 Tel: +86-755-66850100 E-mail: [email protected] Page No. 2 / 15 Web: www.titcgroup.com Template No.: TRP-Passive-EN (2022-01-12) Add: Block B, 1/F, Baisha Science and Technology Park, Shahe West Road, Nanshan District, ShenZhen, GuangDong Province, China Revision History Version Issue Date Revisions Rev. 01 Jul. 05, 2022 Initial Issue TABLE OF CONTENTS 1 GENERAL INFORMATION ........................................................................................................ 3 1.1 Identification of the Testing Laboratory ................................................................................ 3 1.2 Identification of the Responsible Testing Location ............................................................... 3 2 PRODUCT INFORMATION ....................................................................................................... 4 2.1 Applicant Information ........................................................................................................... 4 2.2 Manufacturer Information .................................................................................................... 4 2.3 Factory Information ............................................................................................................. 4 2.4 General Description for Equipment under Test (EUT) ......................................................... 4 2.5 Ancillary Equipment ............................................................................................................. 4 2.6 Technical Information .......................................................................................................... 4 3 SUMMARY OF TEST RESULTS ............................................................................................... 5 3.1 Test Standards .................................................................................................................... 5 3.2 Test Verdict ......................................................................................................................... 5 3.3 Test Uncertainty .................................................................................................................. 5 4 GENERAL TEST CONFIGURATIONS ...................................................................................... 6 4.1 Test Condition ..................................................................................................................... 6 4.2 Test Equipment List ............................................................................................................. 6 4.3 Test Setup ........................................................................................................................... 7 ANNEX A TEST RESULTS ........................................................................................................... 8 A.1 Gain and Efficiency ............................................................................................................. 8 ANNEX B RADIATION PATTERN .............................................................................................. 10 ANNEX C TEST SETUP PHOTO ................................................................................................ 13 ANNEX D EUT PHOTO .............................................................................................................. 14 Report No.: BL-SZ2261068-901 Tel: +86-755-66850100 E-mail: [email protected] Page No. 3 / 15 Web: www.titcgroup.com Template No.: TRP-Passive-EN (2022-01-12) Add: Block B, 1/F, Baisha Science and Technology Park, Shahe West Road, Nanshan District, ShenZhen, GuangDong Province, China 1 GENERAL INFORMATION 1.1 Identification of the Testing Laboratory Company Name Shenzhen BALUN Technology Co., Ltd. Address Block B, 1/F, Baisha Science and Technology Park, Shahe West Road, Nanshan District, ShenZhen, GuangDong Province, China Phone Number +86 755 6685 0100 1.2 Identification of the Responsible Testing Location Test Location Shenzhen BALUN Technology Co., Ltd. Address Block B, 1/F, Baisha Science and Technology Park, Shahe West Road, Nanshan District, ShenZhen, GuangDong Province, China Description All measurement facilities used to collect the measurement data are located at Block B, 1/F, Baisha Science and Technology Park, Shahe West Road, Nanshan District, ShenZhen, GuangDong Province, China Report No.: BL-SZ2261068-901 Tel: +86-755-66850100 E-mail: [email protected] Page No. 4 / 15 Web: www.titcgroup.com Template No.: TRP-Passive-EN (2022-01-12) Add: Block B, 1/F, Baisha Science and Technology Park, Shahe West Road, Nanshan District, ShenZhen, GuangDong Province, China 2 PRODUCT INFORMATION 2.1 Applicant Information Applicant Shanghai Appropriate Gifts., Ltd Address Shanghai Fengxian Occurrence of Zhen Jiang Hai nan Road 404 2.2 Manufacturer Information Manufacturer N/A Address N/A 2.3 Factory Information Factory N/A Address N/A 2.4 General Description for Equipment under Test (EUT) EUT Name Automobile diagnostic instrument Model Name Under Test IO180-IH Antenna Type PCB Antenna Dimensions 9*2mm 2.5 Ancillary Equipment Note: Not applicable. 2.6 Technical Information Frequency Range 2402MHz ~ 2483.5MHz…

Text truncated - open the document above for the full version.

Test Report

verify No.138882342038 Eurofins KCTL Co.,Ltd. 65, Sinwon-ro, Yeongtong-gu, Suwon-si, Gyeonggi-do, 16677, Korea TEL: 82-70-5008-1021 FAX: 82-505-299-8311 www.kctl.co.kr Report No.: KR23-SRF0092-A Page (2) of (32) KCTL-TIR001-003/7 (220705) KP22-07427 REPORT REVISION HISTORY Date Revision Page No 2023-04-04 Originally issued - 2023-04-10 Updated 8 This report shall not be reproduced except in full, without the written approval of Eurofins KCTL Co.,Ltd. This document may be altered or revised by Eurofins KCTL Co.,Ltd. personnel only, and shall be noted in the revision section of the document. Any alteration of this document not carried out by Eurofins KCTL Co.,Ltd. will constitute fraud and shall nullify the document. This test report is a general report that does not use the KOLAS accreditation mark and is not related to KS Q ISO/IEC 17025 and KOLAS accreditation. Note. The report No. KR23-SRF0092 is superseded by the report No. KR23-SRF0092-A. General remarks for test reports Statement concerning the uncertainty of the measurement systems used for the tests (may be required by the product standard or client) Internal procedure used for type testing through which traceability of the measuring uncertainty has been established: Procedure number, issue date and title: Calculations leading to the reported values are on file with the testing laboratory that conducted the testing. Statement not required by the standard or client used for type testing Eurofins KCTL Co.,Ltd. 65, Sinwon-ro, Yeongtong-gu, Suwon-si, Gyeonggi-do, 16677, Korea TEL: 82-70-5008-1021 FAX: 82-505-299-8311 www.kctl.co.kr Report No.: KR23-SRF0092-A Page (3) of (32) KCTL-TIR001-003/7 (220705) KP22-07427 CONTENTS 1. General information ...................................................................................................... 4 2. Device information ........................................................................................................ 4 2.1. Accessory information ............................................................................................ 4 2.2. Information about derivative model ......................................................................... 5 2.3. Frequency/channel operations ................................................................................ 5 2.4. RF power setting in TEST SW ................................................................................ 5 2.5. Duty Cycle Factor ................................................................................................... 6 3. Antenna requirement .................................................................................................... 7 4. Summary of tests .......................................................................................................... 8 5. Measurement uncertainty ............................................................................................. 9 6. Measurement results explanation example ................................................................ 10 7. Test results ................................................................................................................. 11 7.1. Maximum Peak Output Power .............................................................................. 11 7.2. Peak Power Spectral Density ............................................................................... 14 7.3. 6 ㏈ Bandwidth(DTS Channel Bandwidth) .......................................................... 16 7.4. Spurious Emission, Band Edge and Restricted bands .......................................... 18 7.5. Conducted Spurious Emission .............................................................................. 30 8. Measurement equipment ............................................................................................ 32 Eurofins KCTL Co.,Ltd. 65, Sinwon-ro, Yeongtong-gu, Suwon-si, Gyeonggi-do, 16677, Korea TEL: 82-70-5008-1021 FAX: 82-505-299-8311 www.kctl.co.kr Report No.: KR23-SRF0092-A Page (4) of (32) KCTL-TIR001-003/7 (220705) KP22-07427 1. General information Client : Infocar Co., Ltd. Address : Convergence Technology Commercialization Center 6F, 218, Gajeong-ro, Yuseong-gu, Daejeon, Republic of Korea Manufacturer : Infocar Co., Ltd. Address : Convergence Technology Commercialization Center 6F, 218, Gajeong-ro, Yuseong-gu, Daejeon, Republic of Korea Laboratory : KCTL Inc. Address : 65, Sinwon-ro, Yeongtong-gu, Suwon-si, Gyeonggi-do, 16677, Korea Accreditations : FCC Site Designation No: KR0040, FCC Site Registration No: 687132 VCCI Registration No. : R-20080, G-20078, C-20059, T-20056 CAB Identifier: KR0040, ISED Number: 8035A KOLAS No.: KT231 2. Device information Equipment under test : Smart Scanner Model : IO180-SH Derivative Model : IO180-PH Modulation technique : Bluetooth(BDR/BLE) : GFSK Number of channels : Bluetooth : 79 ch BLE : 40 ch Power source : DC 12 V Antenna specification : PCB Antenna Antenna gain : 2.70 ㏈i Frequency range : 2 402 ㎒ ~ 2 480 ㎒(BDR/BLE) Software version : IO180_SW_V2.2 Hardware version : IO180SH_HW_V1.1 Test device serial No. : 188813A-Y753-221101 Operation temperature : -20 °C ~ 70 °C 2.1. Accessory information Equipment Manufacturer Model Serial No. Power source N/A - - - - Eurofins KCTL Co.,Ltd. 65, Sinwon-ro, Yeongtong-gu, Suwon-si, Gyeonggi-do, 16677, Korea TEL: 82-70-5008-1021 FAX: 82-505-299-8311 www.kctl.co.kr Report No.: KR23-SRF0092-A Page (5) of (32) KCTL-TIR001-003/7 (220705) KP22-07427 2.2. Information about derivative model The difference between basic model and derivative models is: The additional model is identical to model IO180-SH except for power switch 2.3. Frequency/channel operations This device contains the following capabilities: Bluetooth(BDR), Bluetooth Low Energy Ch. Frequency (㎒) 00 2 402 . . . . 19 2 440 . . . . 39 2 480 Table 2.3.1. Bluetooth Low Energy 2.4. RF power setting in TEST SW Mode Frequency RF Power setting value Bluetooth Low Energy 2 402 Default 2 440 …

Text truncated - open the document above for the full version.

Test Setup Photos

This document shall not be reproduced, except in full, without the written approval Test setup photos - Below 30 ㎒ (9 ㎑ ~ 30 ㎒) - Below 1 ㎓ (30 ㎒ ~ 1 ㎓) This document shall not be reproduced, except in full, without the written approval - Above 1 ㎓ (1 ㎓ ~ 18 ㎓) - Above 18 ㎓ (18 ㎓ ~ 26.5 ㎓)

Contact Information

Applicant

GeonHo Pyo(Team Leader)
[email protected]+82-10-7684-8243Fax: +82-504-395-7304

Test Firm

Eurofins KCTL Co., Ltd.Sung-su Lim
[email protected]+82-31-326-6719Fax: +82-505-299-8311

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.40 GHz - 2.48 GHz290.00 µW
Confidentiality
Long Term
Grant Notes
Output power listed is conducted. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter device.