FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. SHENZHEN LK TECHNOLOGY CO., LTD/
  3. 2A6AY-N3

2A6AY-N3Charging Pad

SHENZHEN LK TECHNOLOGY CO., LTD
Charging Pad - FCC ID 2A6AY-N3 - SHENZHEN LK TECHNOLOGY CO., LTD
Click to zoom

Application Details

Equipment Class
DCD - Part 15 Low Power Transmitter Below 1705 kHz
Date of Grant
Mar 22, 2023
Application Purpose
Original Equipment
Date of Application
Mar 22, 2023
Equipment Note
Charging Pad
Frequency Range
0.11050000 - 0.20500000
Company
SHENZHEN LK TECHNOLOGY CO., LTD
Country
China

Documents & Files

Select a file to view

Users Manual

↗

Attestation Statements

↗
↗

Cover Letter(s)

↗
↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗
↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

Instructions for use 温控杯使用说明书 Do not fill your above the “MAX” fill line inside your mug. Hot contents may create internal pressure resulting in a hot liquid spray when opening the lid. Always have the mug positioned away from the face when pressing down on the lid to properly release pressure. Temperature control 温度控制 温控杯默认设置温度为57°C,你可 以直接在温控杯上设置饮用温度。 Portable battery life varies by product. Enjoy all-day battery life by regularly placing mug on its included charging coaster . Power button 电源按钮 Touch button 触控按钮 超过“最高”水位线。 向温控杯注水时,请勿 温控杯的 部压力,造成打开盖子时产 生高温雾气。按下盖子时, 务必将杯子放置在远离脸部 的位置,以适当释放压力。 内热容物会产生内 Out of the box, Will keep your drink at 135°F, You can adjust the drinking temperature on the Temperature control travel mug. 温控杯电池续航因使用方式而异,只 要经常将杯子放在随附的充电杯垫 上,可享受全天的的电池续航使用。 旅行杯在充电座上充电使用加热时, 若旅行杯没有任何操作,4小时后自动 停止加热进入充电状态。 *This product is not designed for use with MCT oils. logo logo LOGO Instructions for use When the travel mug is charged on the charging stand and heated, If there is no operation on the travel mug, it will automatically change after 4 hours Stop heating and enter the charging state. Change temperature - Two taps on logo, then tap‘+or-’‘’ 更改温度 - 按两下LOGO,然后轻按 或「-」 「+」 View battery life – Three taps on logo 查看电池续航电量 – 按三下LOGO View current temperature – One tap on Mug logo 查看当前温度 - 轻按一次温控杯LOGO Off – Press and hold power button for 2 seconds 关 - 按住电源按钮2秒关机 On – Press power button once 开 - 按一下电源按钮开机 Package Contents: Temperature control travel mug 360° Leakproof Lid Charging Coaster Power supply Introduction *This product is not designed for use with MCT oils. This product is not designed to be used with MCT oils. MCT oils can sometimes be found in drink or food additives. MCT oils react with plastic materials and can degrade them, including the food-grade plastic used in the Travel Mug lid. MCT oils should only be used with utensils and containers made of metal, glass, ceramic, or materials specifically approved for MCT oils. 充电杯垫可兼容iOS/安卓系统的 智能手机无线充电。 (仅支持带无线充功能的手机) Product Specifications Name: temperature control travel mug Material: stainless steel+ABS+PC plastic Capacity: 12oz/355ml Waterproof grade: IPX7 (submersible up to 1 meter in water) Battery type: built-in lithium-ion battery 保持液体的温度 控温范围:50°C-62.5°C 包装内容: 温控旅行杯 1PCS 360°防漏盖 1PCS 充电杯垫 1PCS 电源供应器 1PCS 使用说明 1PCS 产品规格 品名:温控旅行杯 材质:不锈钢316+ABS+PC 容量:355ml 防水等级:IPX7 (可浸入在一米深的水中) 电池类型:18650 锂电池 7.4V/3200mAh *本产品不适用于 MCT 油。 MCT 油有时可以在饮料或食品添加剂中找到。MCT 油与塑料材料发生反应并可以降解它们, 包括温控旅行杯盖子中使用的食品级塑料。MCT 油只能与由金属、玻璃、陶瓷或特别批准用 于 MCT 油的材料制成的器具和容器一起使用。 LOGO LOGO LOGO 6.65 98.6 172 3.88 weight: 160g Product Specifications LOGO 3 COLD-Displays COLD when the thermal sensor does not detect a temperature change in the inner container 当热传感器未识别出内部容器中存在的温度变化时显示COLD EMPTY-EMPTY is displayed when the temperature of the liquid in the travel mug is below 38°C without heating 旅行杯中液体温度低于38°C 且没有加热时显示EMPTY When the liquid above 38°C is poured into the travel mug, a wavy line is displayed 当旅行杯内部倒入高于38°C液体时,旅行杯内温度传感器检测到热液体显示一条波浪线 Temperature unit switching – When the travel mug displays the current liquid temperature or COLD, double-click the power button to switch the temperature unit display, °F / °C 温度单位切换- 杯子显示当前液体温度或COLD时,双击电源按钮后可切换温度单位显示,华氏度°F/摄氏度°C Instructions for use 3 hours or all day when placed on charging coaster. IPX7, Safe to hand wash keep your drink hot Built-In Battery Wireless charging Temperature Range 120°F - 145°F (50°C - 62.5 °C). Easy to clean and is safe to handwash and submersible up to 1 meter in water. The leak-proof lid is dishwasher safe. On charging coaster. Compatible with iOS / Android smartphone wireless charging. 内置锂电池 在满电状态,续航恒温3个小时, 在杯垫上持续整天恒温。 7级防水 杯子可手洗,杯盖可洗碗机清洗 请勿将微波炉加热温控杯,温控 杯为电子设备,禁止将其放入微 波炉或烤炉中。 保持干燥。在充电前,请确保杯 子底座上的金属环和充电杯垫上 的弹簧针完全干燥。 用。 饮用时请注意安全,请冷却后饮 儿童无法接触到的地方。 温控杯倒入热饮后,请将其放在 放入洗碗机中,可用水瓶刷清洁 温控杯容器内部。 温控杯只能手动清洗,请勿将其 IMPORTANT SAFEGUARDS When using this product, basic safety precautions should always be followed, including the following: 【1】Read all instructions. 【2】Do not place near heat sources or heat – producing devices. Do not touch inside vessel hot surfaces. 【3】Close supervision is necessary when any appliance is used by or near children. 【4】Use only power supply and coaster provided with the product for charging. Do not use any other third – party accessories. 【5】Unplug power supply from the wall when not in use and before cleaning. Clean the power supply and charging coaster with a clean, dry cloth and do not immerse in water or other liquid to protect against fire, electric shock and injury to person. 【6】Do not microwave. Mug is hand wash only. Use water and mild soap to clean. 【7】Do not operate the product with a damaged cord, plug or coaster, or after the product malfunctions. Attempting to open or service the unit voids all warranties and may cause injury to user. If you experience problems with the device, discontinue use and contact dealer for assistance. 【8】If any of the instructions provided are not followed, or the equipment is used in a manner not specified by the manufacturer, the protection provided by the equipment for fire, electric shock or injury to persons may be impaired. 【9】This product is intended for consumable liquids like coffee and tea. 【10】Save these instructions. 使用注意安全事项 使用本产品时,始终应遵守基本安全措施,包括以下内容: 【1】阅读所有说明。 【2】请勿放置在热源或发热装置附近,请勿触摸容器内的发热表面,请勿干烧。 【3】请勿放置在儿童触碰到的地方。 【4】仅可使用产品所附的电源供应器和充电杯垫进行充电,请勿使用任何其他厂商所生产的配 件。 【5】在不使用和清洗前,请从墙上拔下电源插头。请使用干净的干布清洁电源供应器和充电杯 垫,请勿将其浸入水或其他液体中,以防止火灾、触电和人身伤害的发生。 【6】请勿使用微波炉加热。杯子仅可手洗,请用清水河温和的肥皂进行清洗。 【7】请勿使用损坏的电源线、插头和杯垫,或在产品发生故障后使用本产品。请勿试图单独 打 开或维修设备,否则会导致所有保固服务失效,并可能导致用户受伤。如果您遇到设备上的问 题,请停止使用并联系经销商寻求协助。 【8】如果没有遵守所提供的说明,或未按制造商规定的方式使用本产品,那么本产品用于防止 火灾、触电、人体伤害等问题的保护机制可能会受到损坏。 【9】本产品适用于液体,比如咖啡、茶等。 【10】请保存这些说明。 Do not microwave temperature control travel mug, Travel mug is an electronic device, which should never go in a microwave. Dr it well. Ensure gold rings at the base of the mug and pins on charging coaster are dry before charging. Use caution when consuming hot beve…

Text truncated - open the document above for the full version.

Attestation Statements

FCC US Agent, LLC Federal Communications Commission Authorization and Evaluation Division Equipment Authorization Branch 7435 Oakland Mills Road Columbia, MD 21046 3/21/2023 U.S. Agent Designation SHENZHEN LK TECHNOLOGY CO., LTD acknowledges their consent for the following contact located in the United States to act as their agent for service of process for the equipment for which authorization is sought (FCC ID: 2A6AY-N3): Contact Name: Tim Payne Company U.S. agent: FCC US Agent, LLC Physical U.S. address of agent: 3722 Illinois Avenue, Saint Charles, IL, 60174, USA FRN of U.S. agent: 0033402884 Email address of U.S. agent: [email protected] Phone of U.S. agent: 708-571-3148 FCC US Agent, LLC acknowledges their obligation to accept service of process on behalf of SHENZHEN LK TECHNOLOGY CO., LTD. SHENZHEN LK TECHNOLOGY CO., LTD accepts its obligation to maintain an agent for service of process in the United States for no less than one year after either the grantee has permanently terminated all marketing and importation of the applicable equipment within the U.S., or the conclusion of any Commission-related administrative or judicial proceeding involving the equipment, whichever is later. This acceptance will be in effect till the applicant decides to change the agent of service of process. By signing this form, we confirm the above and that we are aware of the application requirements listed under § 2.911(d)(7). Sincerely, Signature Quanhai Chen / SHENZHEN LK TECHNOLOGY CO., LTD Signature Tim Payne Manager FCC US Agent, LLC The information provided in this letter is based on the referenced rule parts of Title 47 of the CFR as well as KDB 986446 D01. An expiration date for this letter does not exist. In case the U.S. agent changes, the grantee is obligated to notify the FCC. 48_[model] US_Agent_2.911(d)(7)-U, V03

Cover Letter(s)

Sincerely, Name/Title: Quanhai Chen/N/A Company: SHENZHEN LK TECHNOLOGY CO., LTD Address: Room 201, 2nd floor, Building A, No.21 Furong Road, Gushu, xixiang Sub-district, Baoan district, Shenzhen, China Phone: 0755-29927887 Fax: 0755-29927887 E-Mail: [email protected]

External Photos

Page1of5FCCID:2A6AY-N3 ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity EXTERIORPHOTOGRAPHS Fig.1 Fig.2 Page2of5FCCID:2A6AY-N3 ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity Fig.3 Fig.4 Page3of5FCCID:2A6AY-N3 ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity Fig.5 Fig.6 Page4of5FCCID:2A6AY-N3 ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity Fig.7 Fig.8 Page5of5FCCID:2A6AY-N3 ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity Fig.9

ID Label/Location Info

Page1of1FCCID:2A6AY-N3 ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity LABELANDLOCATION (Size:L3.5cmx3.0cm) LabelLocation ChargingPad Model:N3 FCCID:2A6AY-N3

Internal Photos

Page1of4FCCID:2A6AY-N3 ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity INTERIORPHOTOGRAPHS Fig.1 Fig.2 Page2of4FCCID:2A6AY-N3 ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity Fig.3 Fig.4 Page3of4FCCID:2A6AY-N3 ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity Fig.5 Fig.6 Page4of4FCCID:2A6AY-N3 ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity Fig.7 CoilAntenna

RF Exposure Info

Page 1 of 11 FCCID:2A6AY-N3 ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity RFExposureEvaluationReport 1.ProductInformation FCCID:2A6AY-N3 Numberoftestedsamples2 SamplenumberA030123081-1(Engineersample),A030123081-2(Normalsample) ProductNameChargingPad ModelNumberN3 AdditionalModelNo.:FOTOJOJO,MUGGO,M1,A1,NILKO,N1,N2,W1,Q1,Q2,F1,F2 ModelDeclaration PCBboard,structureandinternalofthesemodel(s)arethesame,So noadditionalmodelsweretested PowerSupply Input:DC19V,2A Output:DC19V,2A WirelessCharging:5W/7.5W/10W ForACAdapterInput:100-240V~,50/60Hz,0.8AMax AdapterOutput:19V2A ModulationTypeContinuousWave FrequencyRange110.5~205.0KHz AntennaTypeCoilAntenna Hardwareversion/ Softwareversion/ Accessories/ ExposurecategoryGeneralpopulation/uncontrolledenvironment EUTTypeProductionUnit DeviceTypeMobileDevice Page 2 of 11 FCCID:2A6AY-N3 ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity 2.EvaluationMethod PerKDB680106D01Section3.RFExposureRequirements; 1)ConsumerwirelesspowertransferdevicesapprovedunderPart18insomecaseshaveto demonstratecompliancewithRFexposurerequirements.Thepotentialforexposuremustbe assessedaccordingtotheoperatingconfigurationsofthewirelesssystemandtheexposure conditionsofusersandbystanders.RFexposuremustbeevaluatedwiththeclientdevice(s)being chargedbytheprimaryatmaximumoutputpower.TheRFexposurerequirementsmustbe determinedinconjunctionwiththedeviceoperatingcharacteristics,accordingtothemobileand portableexposurerequirementsinSection2.1091andSection2.1093oftherules.SARandMPE limitsdonotcoverthefrequencyrangeforwirelesspowertransferapplicationswhichoperate below100kHzand300kHzrespectively;therefore,RFexposurecomplianceneedstobe determinedwithrespectto1.1307(c)and(d)oftheFCCrules. 2)Basedonthedesignandimplementationofthepowertransferapplication,itmustbeclearly identifiedifmobileorportableRFexposureconditionsapply.Devicesthatareinstalledtoprovide separationofatleast20cmfromusersandbystandersmayqualifyformobileexposureconditions. Forsomeconditionswhereusersandbystandersmaybeexposedatcloserthan20cm,section 2.1091(d)(4)oftherulesmayapply. 3)Fordevicesdesignedfortypicaldesktopapplications,suchawirelesschargingpads,RFexposure evaluationshouldbeconductedassumingauserseparationdistanceof15cm.EandHfield strengthmeasurementsornumericalmodelingmaybeusedtodemonstratecompliance. Measurementsshouldbemadefromallsidesandthetopoftheprimary/clientpair,withthe15cm measuredfromthecenteroftheprobe(s)totheedgeofthedevice.Emissionsbetween100kHzto 300kHzshouldbeassessedversusthelimitsat300kHzinTable1ofSection1.1310:614V/mand 1.63A/m.AKDBinquiryisrequiredtodeterminetheapplicableexposurelimitsbelow100kHz. 4)Portableexposureconditionsfrom100kHzto6GHzaredeterminedwithrespecttoSAR requirements.ExistingSARsystemsandtestproceduresaregenerallyintendedformeasurements above100MHz.Whilenumericalmodelingcanbeanalternative,theconstraintsofsubstantial computationalresourcesatlowfrequenciescouldintroducefurtherlimitations.Underthese circumstances,includingoperationsbelow100kHz,theCommissionmayconsideracombination ofanalyticalanalysis,fieldstrength,radiatedandconductedpowermeasurements,inconjunction withsomelimitednumericalmodelingtoassesscompliance. 5)Dependingontheoperatingfrequency,existingSARandMPEmeasurementproceduresmaybe adaptedtoevaluatewirelesspowertransferdevicesforcompliancewithrespecttomobileor portableexposureconditions.IfthegranteeoritstestlabhaveanyquestionsregardingRF exposureevaluationtheyshouldcontacttheFCCLaboratorywithsufficientsystemoperating configurationdetailstodetermineifRFexposureevaluationisnecessaryand,ifrequired,howto applyspecifictestprocedures.Below100MHz,whenSARtestingisrequiredandthedeviceis operatingatcloseproximitytopersons,informationondevicedesign,implementation,operating configurations,exposureconditionsofusersandbystandersareneededtodeterminethe evaluationandtestingrequirements.Inaddition,theinfluenceofnearbyobjectsmayalsoneed considerationaccordingtothewirelesspowertransfersystemimplementation;forexample,the effectsofplacingthedevice,itscoilsorradiatingelementsonornearmetallicsurfaces Page 3 of 11 FCCID:2A6AY-N3 ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity 3.EvaluationLimit 3.1Referevaluationmethod ANSIC95.1–1999:IEEEStandardforSafetyLevelswithRespecttoHumanExposuretoRadio FrequencyElectromagneticFields,3kHzto300GHz. FCCKDBpublication680106D01RFExposureWirelessChargingAppsv03:RFExposure ConsiderationsforLowPowerConsumerWirelessPowerTransferApplications FCCCFR47part11.1310:Radiofrequencyradiationexposurelimits. FCCCFR47part22.1091:Radiofrequencyradiationexposureevaluation:mobiledevices FCCCFR47part18.107:Indusial,Scientific,andMedicalEquipment Page 4 of 11 FCCID:2A6AY-N3 ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity 3.2Limit LimitsforMaximumPermissibleExposure(MPE)/ControlledExposure Frequency Range(MHz) ElectricField Strength(V/m) MagneticField Strength(A/m) PowerDensity (mW/cm²) AveragingTime (minute) LimitsforOccupational/ControlledExposure 0.3-3.06141.63*1006 3.0-301842/f4.89/f*900/f 2 6 30-30061.40.1631.06 300-1,500//f/3006 1,500-100,000//56 LimitsforMaximumPermissibleExposure(MPE)/UncontrolledExposure Frequency Range(MHz) ElectricField Strength(V/m) MagneticField Str…

Text truncated - open the document above for the full version.

Test Report

FinePage1 of 4 SPECIFICATIONFOR APPROVAL CUSTOMER: SHENZHEN LK TECHNOLOGY CO.,LTD CUSTP/N : FINE P/N : N3 DESC : Φ43.5MMX5.0MMX0.8MM FinePage3 of 4 SPECIFICATION DESC Φ 20.5x43.5 -6. 5uH-0.08x105-40mm-50C Rev:A.0 CUST : XXX CUSTP/N : 1. DIMENSION:(mm ) 2. SCHEMATICDIAGRAM: A 42.5 .0 ±1 B 20.5±0.5 D 40 ±2 E 3±2 F 43±1 G 10 H 2.2 ±0.5 I 5.3 ±0.5 J 43±0.5 K 3max M 8max annotation: 1. Wrap 8mm (Ref) high-temperatureadhesivetape 1-2ts aroundthe outgoingline; 2. The coil is pasted with round hard magneticpiece with slot, the size of magneticpiece is 50 ±1mm, the inner hole is 5.0mm,the thicknessis 0.8± 0.2mm,and the back glue is pasted;

Test Report

Page1of24FCCID:2A6AY-N3ReportNo.:LCSA030123081EA ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity FCCTESTREPORT For SHENZHENLKTECHNOLOGYCO.,LTD ChargingPad TestModel:N3 AdditionalModelNo.:PleaseRefertoPage6 Preparedfor:SHENZHENLKTECHNOLOGYCO.,LTD Address: Room201,2ndfloor,BuildingA,No.21FurongRoad,Gushu, xixiangSub-district,Baoandistrict,Shenzhen,China Preparedby:ShenzhenLCSComplianceTestingLaboratoryLtd. Address: 101,201BldgA&301BldgC,JujiIndustrialParkShajing Street,BaoanDistrict,Shenzhen,China Tel:(+86)755-82591330 Fax:(+86)755-82591332 Web:www.LCS-cert.com Mail:[email protected] Dateofreceiptoftestsample:March03,2023 Numberoftestedsamples:2 Serialnumber:A030123081-1(Engineersample),A030123081-2(Normal sample) DateofTest:March03,2023~March13,2023 DateofReport:March17,2023 Page2of24FCCID:2A6AY-N3ReportNo.:LCSA030123081EA ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity FCCTESTREPORT FCCCFR47PART15C ReportReferenceNo......................:LCSA030123081EA DateOfIssue......................................:March17,2023 TestingLaboratoryName..............:ShenzhenLCSComplianceTestingLaboratoryLtd. Address................................................: 101,201BldgA&301BldgC,JujiIndustrialParkShajingStreet, BaoanDistrict,Shenzhen,China TestingLocation/Procedure............ : FullapplicationofHarmonisedstandards■ PartialapplicationofHarmonisedstandards□ Otherstandardtestingmethod□ Applicant’sName.............................:SHENZHENLKTECHNOLOGYCO.,LTD Address................................................: Room201,2ndfloor,BuildingA,No.21FurongRoad,Gushu, xixiangSub-district,Baoandistrict,Shenzhen,China TestSpecification Standard..............................................:FCCCFR47PART15C TestReportFormNo.........................:LCSEMC-1.0 TRFOriginator....................................:ShenzhenLCSComplianceTestingLaboratoryLtd. MasterTRF.........................................:Dated2011-03 ShenzhenLCSComplianceTestingLaboratoryLtd.Allrightsreserved. Thispublicationmaybereproducedinwholeorinpartfornon-commercialpurposesaslongasthe ShenzhenLCSComplianceTestingLaboratoryLtd.isacknowledgedascopyrightownerandsourceof thematerial.ShenzhenLCSComplianceTestingLaboratoryLtd.takesnoresponsibilityforandwillnot assumeliabilityfordamagesresultingfromthereader'sinterpretationofthereproducedmaterialdueto itsplacementandcontext. TestItemDescription.....................:ChargingPad TradeMark..........................................:NILKO TestModel...........................................:N3 PowerSupply......................................: Input:DC19V,2A Output:DC19V,2AWirelessCharging:5W/7.5W/10W/15W ForACAdapterInput:100-240V~,50/60Hz,0.8AMax AdapterOutput:19V2A Result..................................................: Positive Compiledby:Supervisedby:Approvedby: DiamondLu/AdministratorCaryLuo/Techniqueprincipal GavinLiang/Manager Page3of24FCCID:2A6AY-N3ReportNo.:LCSA030123081EA ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity FCCTESTREPORT TestResultPositive Thetestreportmerelycorrespondstothetestsample. Itisnotpermittedtocopyextractsofthesetestresultwithoutthewrittenpermissionofthetest laboratory. TestReportNo.:LCSA030123081EA March17,2023 Dateofissue TestModel..............................:N3 EUT.........................................:ChargingPad Applicant...............................:SHENZHENLKTECHNOLOGYCO.,LTD Address..................................: Room201,2ndfloor,BuildingA,No.21FurongRoad,Gushu, xixiangSub-district,Baoandistrict,Shenzhen,China Telephone...............................:/ Fax..........................................:/ Manufacturer........................:SHENZHENLKTECHNOLOGYCO.,LTD Address...................................: Room201,2ndfloor,BuildingA,No.21FurongRoad,Gushu, xixiangSub-district,Baoandistrict,Shenzhen,China Telephone...............................:/ Fax..........................................:/ Factory...................................:SHENZHENLKTECHNOLOGYCO.,LTD Address...................................: Room201,2ndfloor,BuildingA,No.21FurongRoad,Gushu, xixiangSub-district,Baoandistrict,Shenzhen,China Telephone...............................:/ Fax..........................................:/ Page4of24FCCID:2A6AY-N3ReportNo.:LCSA030123081EA ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity RevisionHistory ReportVersionIssueDateRevisionContentRevisedBy 000March17,2023InitialIssue-- Page5of24FCCID:2A6AY-N3ReportNo.:LCSA030123081EA ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity TABLEOFCONTENTS 1.GENERALINFORMATION................................................................................................................6 1.1DescriptionofDevice(EUT)........................................................................................................................6 1.2SupportequipmentList................................................................................................................................6 1.3ExternalI…

Text truncated - open the document above for the full version.

Test Setup Photos

Page1of2FCCID:2A6AY-N3 ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity PhotographsofTestSetup ConductedEmission-ACadapterchargemode RadiatedEmissionbelow30MHz-ACadapterchargemode Page2of2FCCID:2A6AY-N3 ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity RadiatedEmissionbelow1GHz-ACadapterchargemode

Contact Information

Applicant

Quanhai Chen
[email protected]0755-29927887Fax: 0755-29927887

Test Firm

Shenzhen LCS Compliance Testing Laboratory Ltd.Gavin Liang
[email protected]0755-82591330Fax: 0755-82591132

Technical Specifications

#Rule PartsFrequency RangePower Output
115C0.1105 MHz - 0.205 MHz-
Confidentiality
Long Term

Other Applications from SHENZHEN LK TECHNOLOGY CO., LTD

Wireless Charging pad - FCC ID 2A6AY-LK57C - SHENZHEN LK TECHNOLOGY CO., LTD
2A6AY-LK57C

Wireless Charging pad

Apr 28, 2022

Equipment Class

DCD - Part 15 Low Power Transmitter Below 1705 kHz