FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Jiangxi Wojin Technology Group Co.,LTd./
  3. 2A6EI-YWK

2A6EI-YWKhandle smart lock

Jiangxi Wojin Technology Group Co.,LTd.
handle smart lock - FCC ID 2A6EI-YWK - Jiangxi Wojin Technology Group Co.,LTd.
Click to zoom

Application Details

Equipment Class
DTS - Digital Transmission System
Date of Grant
Jun 08, 2022
Application Purpose
Original Equipment
Date of Application
Jun 08, 2022
Equipment Note
handle smart lock
Frequency Range
2412.00000000 - 2462.00000000
Company
Jiangxi Wojin Technology Group Co.,LTd.
Country
China

Documents & Files

Select a file to view

Users Manual

↗

Cover Letter(s)

↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

User's Manual ------------------------------------------------------------------------------------------------------------- Pls check the smart lock according to the following list before installation Outside smart lock panel X 1PC Inside smart lock panel X 1PC M1 Card X 2PCS Mechanical key X 2PCS 6068 Mortise X 1PC Frame plate for mortise X 1PC Spindle 8x8x120MM x 1PC Tube connection X 3PCS 5CM screws x 1PC 7CM screws x 1PC 9CM screws x 1PC 5 x 10MM with cap screws x 2PCS Screws for Mortise and plate x 1BAG Manual x 1PC Key technologies and parameters: Information Feature Parameters Power Battery 6V DC (4PCS 1.5V AA Alkaline Battery) Standby current ≤50μA Working current 200MA Low Battery Alarm 4.8V Unlock Capacity <= 300nos. ( 5nos. administrators, 295nos. normal users ) Fingerprint Sensor Semi conductor Code Code numbers 6~10nos. Fake Pin Code is available (within 20nos.) Working temperature -10°C~60°C ------------------------------------------------------------------------------------------------------------- INSTALLATION GUIDE AND NOTE NOTE 1. Installation Tool: 2. Spindle length: Door thickness + 40mm 3. How to change the lock handle to left opening or right opening: in the outside and inside smart lock panel, you will find the handle can turn to left or right. If the door is right opening, then put the handle to be right side, and use 5x10mm with cap screws to fix the handle. And the point should be point to the bottom (please kindly double check before install outside smart lock panel) 4. check the hole is same as our mortise hole, the spindle hole is 35mm and the hole for two tube connection screws is 30mm INSTALLATION GUIDE 1. install the mortise on the door and frame plates on the frame with the 1 bag screws. (you can change the latch direction according to right or left opening) 2. screw 2pcs the tube connections on the outside smart lock panel 3. insert spindle to the mortise handle hole 4. put the cable of outside lock panel from door outside to door inside through the lock hole, install the outside lock panel on the outside of door and connect the spindle to the lock handle hole 5. connect the cable with the cable of inside smart lock panel, then put all the cable into door hole (pls make sure that there is nothing press cable otherwise the lock will not be in good function) 6. use 5cm/7cm/9cm screws to screw the inside lock panel to the door with tube connections on the outside smart lock panel. 7. before tighten the screws, Pls make sure the smart lock is parallel to the door edge, outside lock panel and inside lock panel are on the same horizontal line. 8. Pls lift up the hanle to lock the lock, and use the fingerprint, card, password and keys to unlock the lock. If everything is all right, then finish installation. 9. It is better to install by two people in avoid that the smart lock will fall down while installation Correct hole no need to change Cross Screwdriver Need to re drill hole or make the hole bigger Cross screwdriver, hand held hole opener, chisel, Vice, hand held cutter OPERATION NOTE AND GUIDE NOTE: 1. Pls keep your fingerprint clean while using this lock 2. The new lock is default as factory setting, any fingerprint, card and password 123456# can open the lock 3. If the battery is low, the lock will alarm, pls change the battery in time 4. There will be some dirty on the fingerprint sensor, it might effect the sensor function, pls keep fingerprint sensor clean 5. PLS DO NOT USE CORROSIVE CLEANER TO CLEAN THE LOCK 6. Mechanical keys can open the lock while fingerprint/card/password can not work, so pls put your mechanical keys outside of your house 7. There are two kind users: a) Administrator, 5pcs unlock information (fingerprint, code, card), not only can unlock the lock, but also can operate the lock system. b) normal users, 295pcs unlock information (fingerprint, code, card), only can unlock the lock, can not operate the lock system. 8. Key 2 means “Up”, Key 8 means “Down”, Key 4 means “Left”, Key 6 means “Right” 9. If wrong information for 5 consecutive times, the system will lock for 3 minutes, and can not do any operation in these 3 minutes. 10. The initial administrator password is 123456, each password can set 6-10 nos. after you input the administrator information, the initial password will delete automatically. 11. Fake pin code: you can input any nos. before and after your password, total not more than 20nos. OPRATION GUIDE 1. Enter lock system a) Under initial situation: Press # * 123456# b) if set the administrator information: Press # * then administrator information (fingerprint, password or card) 1 # 1. Add User 2. Delete User 3. System Setting 4. Record Query 1. Add admin fingerprint 2. Add admin card 3. Add admin password If add 5pcs Admin 1. Add admin 2. Add normal user 1. Delete by group 2. Delete by no. 2 # 1 # 2 # 1. Delete all normal user fingerprint 2. Delete all normal user card 3. Delete all normal user password Input ID, Key # confirm, Key * back 1. Time setting 2. Language setting 3. Volume setting 4. locking mode setting 5. Normal on mode setting 6. Factory reset 3 # HOW TO CONNECT TUYA WIFI FCC Caution. This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Any Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmf…

Text truncated - open the document above for the full version.

Cover Letter(s)

C5266091_X8_Ed.1 1/1 LetterofAuthorization JiangxiWojinTechnologyGroupCo.,Ltd. Company:JiangxiWojinTechnologyGroupCo.,Ltd. Address:NewCenturyIndustryArea,Xiangfu,Gaoan,Yichun,Jiangxi, China ProductName:handlesmartlock ModelNumber:YWK WeauthorizeLGAITechnologicalCenterS.A.,RondadelaFontdelCarme,s/n, 08193Bellaterra,Spain,toactonourbehalfonallmattersconcerningthe abovenamedequipment. AnyindividualwithinLGAITechnologicalCenterS.A.isauthorizedtoactonour behalfandtakeactionontheapplication. WedeclarethatauthorizeLGAITechnologicalCenterS.A.,RondadelaFontdel Carme,s/n,08193Bellaterra,Spain,isallowedtoforwardallinformation relatedtotheapprovalprojecttotheFederalCommunicationCommissionand todiscussanyissuesconcerningtheapprovalapplication.Anyandallacts carriedoutbyLGAITechnologicalCenterS.A.onourbehalfshallhavethe sameeffectasactsofourown. Name:JennyLeeDate:2022-05-16 Title:Salesmanager Signatureofapplicant:

Cover Letter(s)

C5266091_X10_Ed.2 1/1 JiangxiWojinTechnologyGroupCo.,Ltd. OfficeofEngineeringTechnology FederalCommunicationsCommission 7435OaklandMillsRoad Columbia,MD21046 Date:2022-05-16 Subject:RequestforConfidentiality FCCID:2A6EI-YWK ToWhomItMayConcern, PursuanttotheprovisionsofSections0.457and0.459ofCommission'srules (47CFR0.457,0.459),wearerequestingtheCommissiontowithholdthefollowing attachment(s)asconfidentialdocumentfrompublicdisclosure. ExhibitsLong-Term Confidentiality Short-Term Confidentiality NOTE2 IDLabel/LocationNoNo AttestationStatementNoNo ExternalPhotosNo ☐ BlockDiagram ☒☐ Schematics ☒☐ TestReportNoNo TestSetupPhotosNo ☐ User’sManual ☐ NOTE 1 ☐ InternalPhotos ☐ NOTE 1 ☐ PartsList/TuneUp ☐☐ RFExposureInfoNoNo OperationalDescription ☒☐ CoverLetter(s)NoNo SDRSoftware/SecurityInfo ☐ No NOTE1:Long-TermConfidentialitymaybepermittedunderspecialconditions(SeeII.LONG-TERMCONFIDENTIALITY,Section3of KDB726920,uselastinforce) NOTE2:Short-TermConfidentialitycanberequestedforamaximumof180daysfromthedateofthegrant. Abovementioneddocumentcontainsdetailedsystemandequipmentdescriptionare consideredasproprietaryinformationinoperationoftheequipment.Thepublic disclosureofabovedocumentsmightbeharmfultoourcompanyandwouldgive competitoranunfairadvantageinthemarket. Incaseofshort-termConfidentiality,theapplicantrequeststheexhibitsselected abovearewithheldfrompublicviewforaperiodofdaysfromthedateofthe GrantofEquipmentAuthorizationandpriortomarketing. Itisourunderstandingthatallmeasurementtestreports,FCCIDlabelformatand correspondentduringcertificationreviewprocesscannotbegrantedasconfidential documentsandthoseinformationwillbeavailableforpublicreviewoncethegrantof equipmentauthorizationisissued. Sincerely, C5266091_X10_Ed.2 1/1 Signature: Name:JennyLee Title:Salesmanager

Internal Photos

ANT

RF Exposure Info

Report No.: PTC22031503805E-FC02 Page 1 of 7 FCC TEST REPORT FCC ID: 2A6EI-YWK Product Name : handle smart lock Model Name : YWK Brand : Eiysie Report No. : PTC22041300402E-FC02 Prepared for Jiangxi Wojin Technology Group Co.,Ltd. New Century Industry Area, Xiangfu, Gaoan, Yichun, Jiangxi, China Prepared by Precise Testing & Certification Co., Ltd. Building 1, No. 6, Tongxin Road, Dongcheng Street, Dongguan, Guangdong, China. Report No.: PTC22031503805E-FC02 Page 2 of 7 TEST RESULT CERTIFICATION Applicant’s name : Jiangxi Wojin Technology Group Co.,Ltd. Address : New Century Industry Area, Xiangfu, Gaoan, Yichun, Jiangxi, China Manufacture's name : Jiangxi Wojin Technology Group Co.,Ltd. Address : New Century Industry Area, Xiangfu, Gaoan, Yichun, Jiangxi, China Product name : handle smart lock Model name : YWK Test procedure : FCC CFR47 Part 15 Section 15.247 Test Date : Apr. 14, 2022 to Apr. 28, 2022 Date of Issue : Apr. 28, 2022 Test Result : PASS This device described above has been tested by PTC, and the test results show that the equipment under test (EUT) is in compliance with the FCC requirements. And it is applicable only to the tested sample identified in the report. This report shall not be reproduced except in full, without the written approval of PTC, this document may be altered or revised by PTC, personal only, and shall be noted in the revision of the document. Test Engineer: Simon Pu / Engineer Technical Manager: Ronnie Liu / Manager Report No.: PTC22031503805E-FC02 Page 3 of 7 Contents Page 2 TEST SUMMARY .............................................................................................................................................. 4 3 GENERAL INFORMATION ............................................................................................................................. 5 3.1 GENERAL DESCRIPTION OF E.U.T. ......................................................................................................... 5 4 RF EXPOSURE ................................................................................................................................................. 6 4.1 REQUIREMENTS ....................................................................................................................................... 6 4.2 THE PROCEDURES / LIMIT ........................................................................................................................ 6 4.3 MPE CALCULATION METHOD ................................................................................................................. 7 4.4 TEST RESULT .......................................................................................................................................... 7 Report No.: PTC22031503805E-FC02 Page 4 of 7 2 Test Summary Test Items Test Requirement Result Maximum Permissible Exposure (Exposure of Humans to RF Fields) 1.1307(b)(1) PASS Remark: N/A: Not Applicable Report No.: PTC22031503805E-FC02 Page 5 of 7 3 General Information 3.1 General Description of E.U.T. Product Name : handle smart lock Model Name : YWK Specification : 802.11b/g/n HT20 Operation Frequency : 2412-2462MHz for 802.11b/g/ n(HT20) Number of Channel : 11 channels for 802.11b/g/ n(HT20) Type of Modulation : DSSS with DBPSK/DQPSK/CCK for 802.11b; OFDM with BPSK/QPSK/16QAM/64QAM for 802.11g/n; Antenna installation : PCB antenna Antenna Gain : 2.5 dBi Power supply : Battery:AA*4(1.5V) Hardware Version : N/A Software Version : N/A Report No.: PTC22031503805E-FC02 Page 6 of 7 4 RF Exposure Test Requirement : FCC Part 1.1307(b)(1) Evaluation Method : FCC Part 2.1091 4.1 Requirements Systems operating under the provisions of this section shall be operated in a manner that ensures that the public is not exposed to radio frequency energy levels in excess limit for maximum permissible exposure. In accordance with 47 CFR FCC Part 2 Subpart J, section 2.1091 this device has been defined as a mobile device whereby a distance of 0.2 m normally can be maintained between the user and the device. 4.2 The procedures / limit (A) Limits for Occupational / Controlled Exposure Frequency Range (MHz) Electric Field Strength (E) (V/m) Magnetic Field Strength (H) (A/m) Power Density (S) (mW/ cm 2 ) Averaging Time |E| 2 ,|H| 2 or S (minutes) 0.3-3.0 614 1.63 (100)* 6 3.0-30 1842 / f 4.89 / f (900 / f)* 6 30-300 61.4 0.163 1.0 6 300-1500 F/300 6 1500-100,000 5 6 (B) Limits for General Population / Uncontrolled Exposure Frequency Range (MHz) Electric Field Strength (E) (V/m) Magnetic Field Strength (H) (A/m) Power Density (S) (mW/ cm2) Averaging Time |E|2,|H|2 or S (minutes) 0.3-1.34 614 1.63 (100)* 30 1.34-30 824/f 2.19/f (180/f)* 30 30-300 27.5 0.073 0.2 30 300-1500 F/1500 30 1500-100,000 1.0 30 Note: f = frequency in MHz ; *Plane-wave equivalent power density Report No.: PTC22031503805E-FC02 Page 7 of 7 4.3 MPE Calculation Method E (V/m) = d GP30 Power Density: Pd (W/m²) = 377 2 E E = Electric field (V/m) P = Peak RF output power (W) G = EUT Antenna numeric gain (numeric) d = Separation distance between radiator and human body (m) The formula can be changed to Pd = 2 377 30 d GP   From the peak EUT RF output power, the minimum mobile separation distance, d=0.2m, as well as the gain of the used antenna, the RF power density can be obtained 4.4 Test Result Item Antenna Gain (numeric) Max. Peak Output Power (dBm) Max. Tune-up Power (dBm) Max. Tune-up Power (mw) Power Density (mW/cm2) Limit of Power Density (mW/cm2) Result 2412 1.78 20.79 21.00 0.125893 0.445379 1 Pass ******THE END REPORT******

Test Report

Page 1 of 60 FCC TEST REPORT FCC ID: 2A6EI-YWK Product Name : handle smart lock Model Name : YWK Brand : Eiysie Report No. : PTC22041300402E-FC01 Prepared for Jiangxi Wojin Technology Group Co.,Ltd. New Century Industry Area, Xiangfu, Gaoan, Yichun, Jiangxi, China Prepared by Precise Testing & Certification Co., Ltd Building 1, No. 6, Tongxin Road, Dongcheng Street, Dongguan, Guangdong, China Report No.: PTC22041300402E-FC01 Page 2 of 60 1 TEST RESULT CERTIFICATION Applicant’s name : Jiangxi Wojin Technology Group Co.,Ltd. Address : New Century Industry Area, Xiangfu, Gaoan, Yichun, Jiangxi, China Manufacture's name : Jiangxi Wojin Technology Group Co.,Ltd. Address : New Century Industry Area, Xiangfu, Gaoan, Yichun, Jiangxi, China Product name : handle smart lock Model name : YWK Standards : FCC CFR47 Part 15 Section 15.247 Test procedure : ANSI C63.10:2013 Test Date : Apr. 14, 2022 to Apr. 28, 2022 Date of Issue : Apr. 28, 2022 Test Result : Pass This device described above has been tested by PTC, and the test results show that the equipment under test (EUT) is in compliance with the FCC requirements. And it is applicable only to the tested sample identified in the report. This report shall not be reproduced except in full, without the written approval of PTC, this document may be altered or revised by PTC, personal only, and shall be noted in the revision of the document. Test Engineer: Simon Pu / Engineer Technical Manager: Ronnie Liu / Manager Report No.: PTC22041300402E-FC01 Page 3 of 60 Contents Page 1 TEST RESULT CERTIFICATION .............................................................................................................................. 2 2 TEST SUMMARY ......................................................................................................................................................... 5 3 GENERAL INFORMATION ........................................................................................................................................ 6 3.1 GENERAL DESCRIPTION OF E.U.T. .................................................................................................................... 6 3.2 CHANNEL LIST .................................................................................................................................................... 7 3.3 TEST SITE ........................................................................................................................................................... 8 4 EQUIPMENT DURING TEST ..................................................................................................................................... 9 4.1 EQUIPMENTS LIST............................................................................................................................................... 9 4.2 MEASUREMENT UNCERTAINTY ......................................................................................................................... 11 4.3 DESCRIPTION OF SUPPORT UNITS ................................................................................................................... 12 5 CONDUCTED EMISSION ......................................................................................................................................... 13 5.1 E.U.T. OPERATION ........................................................................................................................................... 13 5.2 EUT SETUP ...................................................................................................................................................... 13 5.3 TEST SET-UP (BLOCK DIAGRAM OF CONFIGURATION) .................................................................................. 14 5.4 MEASUREMENT PROCEDURE ........................................................................................................................... 14 5.5 CONDUCTED EMISSION LIMIT ........................................................................................................................... 14 5.6 MEASUREMENT DESCRIPTION .......................................................................................................................... 14 5.7 CONDUCTED EMISSION TEST RESULT ............................................................................................................. 14 6 RADIATED SPURIOUS EMISSIONS ..................................................................................................................... 15 6.1 EUT OPERATION .............................................................................................................................................. 15 6.2 TEST SETUP ..................................................................................................................................................... 16 6.3 SPECTRUM ANALYZER SETUP .......................................................................................................................... 17 6.4 TEST PROCEDURE ............................................................................................................................................ 18 6.5 SUMMARY OF TEST RESULTS .......................................................................................................................... 19 7 CONDUCTED SPURIOUS EMISSION ................................................................................................................... 26 7.1 TEST PROCEDURE ............................................................................................................................................ 26 7.2 TEST RESULT ................................................................................................................................................... 26 8 BAND EDGE MEASUREMENT ............................................................................................................................... 36 Report No.: PTC22041300402E…

Text truncated - open the document above for the full version.

Test Setup Photos

RadiatedEmissions From30MHz-1000MHz TestfrequencyfromAbove1GHz

Contact Information

Applicant

Jenny Lee(Sales manager)
[email protected]0086-18757158255Fax: 0086-18757158255

Technical Contact

Jiangxi Wojin Technology Group Co.,Ltd.Jenny Lee
[email protected]0086-18757158255

Yichun · China

Test Firm

Precise Testing & Certification Co., LTD.Chris Du
[email protected]+86-769-38808222

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.41 GHz - 2.46 GHz119.95 mW
Confidentiality
Long Term
Grant Notes
Output power listed is conducted. This device has 20 MHz bandwidth mode. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and not be co-located with any other transmitters except in accordance with FCC multi-transmitter product procedures. End-users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance.