2A6FV-AMK-MS013 in 1 Wireless charging station

Shenzhen Amanki Technology Co., LTD
3 in 1 Wireless charging station - FCC ID 2A6FV-AMK-MS01 - Shenzhen Amanki Technology Co., LTD
Click to zoom

Application Details

Equipment Class
DCD - Part 15 Low Power Transmitter Below 1705 kHz
Date of Grant
Apr 24, 2022
Application Purpose
Original Equipment
Date of Application
Apr 24, 2022
Equipment Note
3 in 1 Wireless charging station
Frequency Range
0.11030000 - 0.20500000
Company
Shenzhen Amanki Technology Co., LTD
Country
China

Documents & Files

Select a file to view

Users Manual

↗

Cover Letter(s)

↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

RF Exposure Info

↗

Test Report

↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

User Manual Safety Instruction Please read all information before using it. If you don’t use it properly, it may be damaged. 1. Please read the Manual carefully before using it 2. Please choose right adapter, make sure it has safety certification. 3. Please don’t repair or disassemble the product yourself. 4. Please keep the product away from humid environment. 5. Please keep it away from your children, it’s not a toy 6. Please check if your device compatible with this product, make sure your device support magnetic and are Qi-enabled. 7.Disassemble the product yourself may cause warranty invalid Product Description This is a 3 in 1 Wireless charging station for iPhone 12/13 series, Airpods and Apple Watch. With it you can charge your iPhone, airpods and apple watch at the same time. Max out put iPhone 10w, airpods 5w and apple watch 3w. Comes with a 15W fast charging adapter and usb a to c cable. Specification Name: 3 in 1 wireless charging station Model: AMK-MS01 Material:ABS+PC, Aluminum alloy Input: DC 5V/3A,9V/2.2A(MAX) Output: 1.Magnetic area for iPhone: 5W, 7.5W, 10W(MAX) 2.For apple watch: 3W(MAX) 3.For airpods: 5W(MAX) Product size: 3.7 x 3.0 x 6.0 inch N.W.: 220g Operation tips First please connect this charging station and adapter(included in box) with the included USB cable, then plug adapter to the power source. Charger’s green light will turn on for about 10 seconds and then turn off automatically, now you can charge your devices. 1. Charge iPhone Put your iPhone 12/13 on this charger’s upper magnetic charging area with or without a Magsafe case, charging will begin 2. Charge Apple watch Put your apple watch on the charger’s back watch magnetic charging area,it will charge the watch 3. Charge Airpods Put your Airpods pro/2/1 on the charger’s below wireless charging pad, it will charge airpods FCC Information This device complies with Part 15 of the FCC rules. Operation is subject to the following two conditions: 1) this device may not cause harmful interference, and 2) this device must accept any interference received, including interference that may cause undesired operation. Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: --Reorient or relocate the receiving antenna. --Increase the separation between the equipment and receiver. --Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. --Consult the dealer or an experienced radio/TV technician for help. Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. Radiation Exposure Statement This device complies with FCC RF radiation exposure limits set forth for an uncontrolled environment. This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter. During the operation of device a distance of 15 cm surrounding the device and 20 cm above the top surface of the device must be respected.

Cover Letter(s)

Shenzhen Amanki Technology Co., LTD Agent Authorization Company: Shenzhen Amanki Technology Co., LTD Address: Room 1710 Building Huitong, No 10 Road Longgang, Pingnan Community, Longgang District, Shenzhen, Guangdong, China Product Name: 3 in 1 Wireless charging station Trade Mark: U-good Model Number(s): AMK-MS01 FCC ID: 2A6FV-AMK-MS01 We authorize MiCOM Labs Inc., 575 Boulder Court, Pleasanton, California 94566, USA, to act on our behalf on all matters concerning the certification of above named equipment. We declare that MiCOM Labs Inc. is allowed to forward all information related to the approval and certification of equipment to the regulatory agencies as required and to discuss any issues concerning the approval application. Any and all acts carried out by MiCOM Labs on our behalf shall have the same effect as acts of our own. Signature: Date: 2022-04-19 Name: Ahui Cui Title: Project Manager Company: Shenzhen Amanki Technology Co., LTD

External Photos

Page 1 of 4 FCC ID: 2A6FV-AMK-MS01 Shenzhen LCS Compliance Testing Laboratory Ltd. Add:101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity 1. EXTERIOR PHOTOGRAPHS Fig. 1 Fig. 2 Page 2 of 4 FCC ID: 2A6FV-AMK-MS01 Shenzhen LCS Compliance Testing Laboratory Ltd. Add:101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Fig. 3 Fig. 4 Page 3 of 4 FCC ID: 2A6FV-AMK-MS01 Shenzhen LCS Compliance Testing Laboratory Ltd. Add:101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Fig. 5 Fig. 6 Page 4 of 4 FCC ID: 2A6FV-AMK-MS01 Shenzhen LCS Compliance Testing Laboratory Ltd. Add:101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Fig. 7 Fig. 8

ID Label/Location Info

Shenzhen LCS Compliance Testing Laboratory Ltd. FCC ID: 2A6FV-AMK-MS01 This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd. Page 1 of 1 Label and Location Size: L: 2.0cm*W: 2.0cm Label Location 3 in 1 Wireless charging station Model No.: AMK-MS01 FCC ID : 2A6FV-AMK-MS01 Input: 5V 3A, 9V 2.2A Output: 5W/7.5W/10W(Phone) 3W (Apple Watch 2/3/4/5/6/7/SE) 5W(TWS Earphone) This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Made In China

RF Exposure Info

Page 1 of 10 FCC ID: 2A6FV-AMK-MS01 Shenzhen LCS Compliance Testing Laboratory Ltd. Add:101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity RF Exposure Evaluation Report 1. Product Information FCC ID: 2A6FV-AMK-MS01 Number of tested samples 2 Sample number 220406007A-1(Engineer sample), 220406007A-2(Normal sample) Product Name 3 in 1 Wireless charging station Model Number AMK-MS01 Power Supply Input: 5V3A, 9V2.2A Output: 5W/7.5W/10W(Phone) 3W (Apple Watch 2/3/4/5/6/7/SE) 5W(TWS Earphone) Modulation Type Continuous Wave Frequency Range 110.3~205.0KHz Antenna Type Coil Antenna Hardware version / Software version / Accessories / Exposure category General population/uncontrolled environment EUT Type Production Unit Device Type Mobile Device 2. Evaluation Method Per KDB 680106 D01 Section 3. RF Exposure Requirements; 1) Consumer wireless power transfer devices approved under Part 18 in some cases have to demonstrate compliance with RF exposure requirements. The potential for exposure must be assessed according to the operating configurations of the wireless system and the exposure conditions of users and bystanders. RF exposure must be evaluated with the client device(s) being charged by the primary at maximum output power. The RF exposure requirements must be determined in conjunction with the device operating characteristics, according to the mobile and portable exposure requirements in Section 2.1091 and Section 2.1093 of the rules. SAR and MPE limits do not cover the frequency range for wireless power transfer applications which operate below 100 kHz and 300 kHz respectively; therefore, RF exposure compliance needs to be determined with respect to 1.1307 (c) and (d) of the FCC rules. 2) Based on the design and implementation of the power transfer application, it must be clearly identified if mobile or portable RF exposure conditions apply. Devices that are installed to provide separation of at least 20 cm from users and bystanders may qualify for mobile exposure conditions. For some conditions where users and bystanders may be exposed at closer than 20 cm, section 2.1091(d) (4) of the rules may apply. 3) For devices designed for typical desktop applications, such a wireless charging pads, RF exposure evaluation should be conducted assuming a user separation distance of 15 cm. E and H field strength measurements or numerical modeling may be used to demonstrate compliance. Measurements should be made from all sides and the top of the primary/client pair, with the 15 cm measured from the center of the probe(s) to the edge of the device. Emissions between 100 kHz to 300 kHz should be assessed versus the limits at 300 kHz in Table 1 of Section 1.1310: 614 V/m and 1.63 A/m. A KDB inquiry is required Page 2 of 10 FCC ID: 2A6FV-AMK-MS01 Shenzhen LCS Compliance Testing Laboratory Ltd. Add:101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity to determine the applicable exposure limits below 100 kHz. 4) Portable exposure conditions from 100 kHz to 6 GHz are determined with respect to SAR requirements. Existing SAR systems and test procedures are generally intended for measurements above 100 MHz. While numerical modeling can be an alternative, the constraints of substantial computational resources at low frequencies could introduce further limitations. Under these circumstances, including operations below 100 kHz, the Commission may consider a combination of analytical analysis, field strength, radiated and conducted power measurements, in conjunction with some limited numerical modeling to assess compliance. 5) Depending on the operating frequency, existing SAR and MPE measurement procedures may be adapted to evaluate wireless power transfer devices for compliance with respect to mobile or portable exposure conditions. If the grantee or its test lab have any questions regarding RF exposure evaluation they should contact the FCC Laboratory with sufficient system operating configuration details to determine if RF exposure evaluation is necessary and, if required, how to apply specific test procedures. Below 100 MHz, when SAR testing is required and the device is operating at close proximity to persons, information on device design, implementation, operating configurations, exposure conditions of users and bystanders are needed to determine the evaluation and testing requirements. In addition, the influence of nearby objects may also need consideration according to the wireless power transfer system implementation; for example, the effects of placing the device, its coils or radiating elements on or near metallic surfaces 3. Evaluation Limit 3.1 Refer evaluation method ANSI C95.1–1999: IEEE Standard for Safety Levels with Respect to Human Exposure to Radio Frequency Electromagnetic Fields, 3 kHz to 300 GHz. FCC KDB publication 680106 D01 RF Exposure Wireless Charging Apps v03: RF Exposure Considerations for Low Power Consumer Wireless Power Transfer Applications FCC CFR 47 part1 1.1310: Radiofrequency radiation exposure limits. FCC CFR 47 part2 2.1091: Radiofrequency radiation exposure evaluation: mobile devices FCC CFR 47 part 18.107:Indusial, Scientific, and Medical Equipment Page 3 of 10 FCC ID: 2A6FV-AMK-MS01 Shenzhen LCS Compliance Testing Laboratory Ltd. Add:101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity 3.2 Limit Limits for Maximum Permissible Exposure (MPE)/Controlled Exposure Frequency Range(MHz) Electric Field Strength(V/m) Magnetic Field Stren…

Text truncated - open the document above for the full version.

Test Report

Page 1 of 22 FCC ID: 2A6FV-AMK-MS01 Report No.: LCS220406007AEA Shenzhen LCS Compliance Testing Laboratory Ltd. Add:101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity FCC TEST REPORT For Shenzhen Amanki Technology Co., LTD 3 in 1 Wireless charging station Test Model: AMK-MS01 Prepared for : Shenzhen Amanki Technology Co., LTD Address : Room 1710 Building Huitong, No 10 Road Longgang, Pingnan Community, Longgang District, Shenzhen, Guangdong, China Prepared by : Shenzhen LCS Compliance Testing Laboratory Ltd. Address : 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Shajing Street, Baoan District, Shenzhen, China Tel : (+86)755-82591330 Fax : (+86)755-82591332 Web : www.LCS-cert.com Mail : [email protected] Date of receipt of test sample : April 06, 2022 Number of tested samples : 2 Serial number : 220406007A-1(Engineer sample), 220406007A-2(Normal sample) Date of Test : April 06, 2022 ~ April 12, 2022 Date of Report : April 13, 2022 Page 2 of 22 FCC ID: 2A6FV-AMK-MS01 Report No.: LCS220406007AEA Shenzhen LCS Compliance Testing Laboratory Ltd. Add:101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity FCC TEST REPORT FCC CFR 47 PART 15C Report Reference No. ................. : LCS220406007AEA Date Of Issue ................................. : April 13, 2022 Testing Laboratory Name ............ : Shenzhen LCS Compliance Testing Laboratory Ltd. Address .......................................... : 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Shajing Street, Baoan District, Shenzhen, China Testing Location/ Procedure .......... : Full application of Harmonised standards â–  Partial application of Harmonised standards â–ˇ Other standard testing method â–ˇ Applicant’s Name ......................... : Shenzhen Amanki Technology Co., LTD Address .......................................... : Room 1710 Building Huitong, No 10 Road Longgang, Pingnan Community, Longgang District, Shenzhen, Guangdong, China Test Specification Standard ......................................... : FCC CFR 47 PART 15C Test Report Form No...................... : LCSEMC-1.0 TRF Originator ................................ : Shenzhen LCS Compliance Testing Laboratory Ltd. Master TRF..................................... : Dated 2011-03 Shenzhen LCS Compliance Testing Laboratory Ltd. All rights reserved. This publication may be reproduced in whole or in part for non-commercial purposes as long as the Shenzhen LCS Compliance Testing Laboratory Ltd. is acknowledged as copyright owner and source of the material. Shenzhen LCS Compliance Testing Laboratory Ltd. takes no responsibility for and will not assume liability for damages resulting from the reader's interpretation of the reproduced material due to its placement and context. Test Item Description. .................. : 3 in 1 Wireless charging station Trade Mark ..................................... : U-good Test Model ...................................... : AMK-MS01 Power Supply ................................. : Input: 5V3A, 9V2.2A Output: 5W/7.5W/10W(Phone) 3W (Apple Watch 2/3/4/5/6/7/SE) 5W(TWS Earphone) Result ........................................... : Positive Compiled by: Supervised by: Approved by: Jack Liu/ Administrator Jin Wang/ Technique principal Gavin Liang/ Manager Page 3 of 22 FCC ID: 2A6FV-AMK-MS01 Report No.: LCS220406007AEA Shenzhen LCS Compliance Testing Laboratory Ltd. Add:101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity FCC TEST REPORT Test Result Positive The test report merely corresponds to the test sample. It is not permitted to copy extracts of these test result without the written permission of the test laboratory. Test Report No. : LCS220406007AEA April 13, 2022 Date of issue Test Model.............................. : AMK-MS01 EUT......................................... : 3 in 1 Wireless charging station Applicant............................... : Shenzhen Amanki Technology Co., LTD Address.................................. : Room 1710 Building Huitong, No 10 Road Longgang, Pingnan Community, Longgang District, Shenzhen, Guangdong, China Telephone............................... : / Fax.......................................... : / Manufacturer........................ : Shenzhen Amanki Technology Co., LTD Address................................... : Room 1710 Building Huitong, No 10 Road Longgang, Pingnan Community, Longgang District, Shenzhen, Guangdong, China Telephone............................... : / Fax.......................................... : / Factory................................... : Shenzhen Amanki Technology Co., LTD Address................................... : Room 1710 Building Huitong, No 10 Road Longgang, Pingnan Community, Longgang District, Shenzhen, Guangdong, China Telephone............................... : / Fax.......................................... : / Page 4 of 22 FCC ID: 2A6FV-AMK-MS01 Report No.: LCS220406007AEA Shenzhen LCS Compliance Testing Laboratory Ltd. Add:101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Revision History Report Version Issue Date Revision Content Revised By 000 April 13, 2022 Initial Issue Gavin Liang Page 5 of 22 FCC ID: 2A6FV-AMK-MS01 Report No.: LCS220406007AEA Shenzhen LCS Compliance Testing Laboratory Ltd. Add:101, 201 Bldg A & 301 Bldg C, Juji In…

Text truncated - open the document above for the full version.

Test Setup Photos

Page 1 of 2 FCC ID: 2A6FV-AMK-MS01 Shenzhen LCS Compliance Testing Laboratory Ltd. Add:101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Photographs of Test Setup Conducted Emission-AC adapter charge mode Radiated Emission below 30MHz-AC adapter charge mode Page 2 of 2 FCC ID: 2A6FV-AMK-MS01 Shenzhen LCS Compliance Testing Laboratory Ltd. Add:101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Radiated Emission below 1GHz-AC adapter charge mode

Contact Information

Applicant

Ahui Cui(Project Manager)
[email protected]15019282387Fax: 0755-23908786

Technical Contact

Shenzhen Amanki Technology Co., LTD
[email protected]

China

Test Firm

Shenzhen LCS Compliance Testing Laboratory Ltd.Gavin Liang
[email protected]0755-82591330Fax: 0755-82591132

Technical Specifications

#Rule PartsFrequency RangePower Output
115C0.1103 MHz - 0.205 MHz-
Confidentiality
Long Term