Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
FCC ID LABEL: Ca. 5mm x 15mm Label Location FCC ID: 2A6JY-AT2631
FCC RF Exposure EUT Description: Smart Tracker Model No.: AT2631-841152 FCC ID: 2A6JY-AT2631 1. Limits According to KDB 447498 D01 General RF Exposure Guidance v01 The 1‐g and 10‐g SAR test exclusion thresholds for 100 MHz to 6 GHz at test separation distances ≤50 mm are determined by: [(max power of channel, including tune‐up tolerance, mW)/(min. test separation distance, mm)]·[√f(GHz)]≤3.0 for 1‐g SAR and ≤ 7.5 for 10‐g extremity SAR, Where: Result=P/D*√F F= the RF channel transmit frequency in GHz P=Maximum turn‐up power in mw D=Min. test separation distance in mm 2. Test Result of RF Exposure Evaluation Output power (dBm) Tune Up Power (dBm) Max Tune Up power dBm/mW Min test separati on distance mm Result Limit SAR Test Exclusion 2440 5.43 5±1(6) 3.98 5 1.24373 3.0 Pass Note: PK Output power= conducted power. Conducted power see the test report HK2408134586-E, antenna gain=-0.08dBi Per KDB 447498 D01, when the minimum test separation distance is < 5 mm, a distance of 5 mm is applied to determine SAR test exclusion. The test exclusion threshold is 1.24373 which is<= 3, SAR testing is not required. Note: Exclusion Thresholds Results=[(max. power of channel, including tune-up tolerance, mW)/(min. test separation distance, mm)] ·[√f (GHz)] f(GHz) is the RF channel transmit frequency in GHz Distance=5mm
Lenze Technology Co.,LTD Tel:+86 0755-82031775;25332530 Fax:+86 0755-82713604 26c newspaper west tower, 6008 shennan Avenue,Futian District, Shenzhen City, GuangdongProvince,China GENERAL INFORMATION 1.1 Test Environment Condition Ambient Temperature 19 to 25 °C Ambient Relative 45 to 55 % Humidity Ambient Pressure N/A (Not applicable) 1.2 Announce (1) The test report is invalid if not marked with the signatures of the persons responsible for preparing and approving the test report. (2) The test report is invalid if there is any evidence and/or falsification. (3) The results documented in this report apply only to the tested sample, under the conditions and modes of operation as described herein. (4) This document may not be altered or revised in any way unless done so and all revisions are duly noted in the revisions section. (5) Content of the test report, in part or in full, cannot be used for publicity and/or promotional purposes without prior written approval from the laboratory. Lenze Technology Co.,LTD Tel:+86 0755-82031775;25332530 Fax:+86 0755-82713604 26c newspaper west tower, 6008 shennan Avenue,Futian District, Shenzhen City, GuangdongProvince,China PRODUCT INFORMATION 2.1 Applicant Applicant Lenze Technology Co.,LTD Address d.c., 26c newspaper west tower, 6008 shennan Avenue, Futian District , Contact Person Tony Telephone Number +86 0755-82031775;25332530 Fax Number +86 0755-82713604 E-mail Address [email protected] 2.2 Manufacturer Manufacturer Lenze Technology Co.,LTD Address d.c., 26c newspaper west tower, 6008 shennan Avenue, Futian District , Shenzhen City, Guangdong Province, China Contact Person N/A Telephone Number N/A Fax Number N/A E-mail Address N/A 2.3 General Description for Equipment under Test (EUT) EUT Type Bluetooth Antenna Model Name PCB Antenna Antenna Type PCB Antenna Hardware Version N/A Serial Number N/A Dimensions N/A 2.4 Technical Information Frequency Range 2400MHz~ 2500MHz Test Frequencies 2402MHz, 2441MHz, 2480MHz Lenze Technology Co.,LTD Tel:+86 0755-82031775;25332530 Fax:+86 0755-82713604 26c newspaper west tower, 6008 shennan Avenue,Futian District, Shenzhen City, GuangdongProvince,China SUMMARY OF TEST RESULTS 3.1 Test Standards No. Identity Document Title 1 IEEE149-1979 IEEE Standard Test Procedures for Antennas 3.2 Test Verdict Report Section Description Remark ANNEX A.1 Gain And Efficiency -- ANNEX B Radiation Pattern -- 3.3 Test Uncertainty The uncertainty is calculated using the methods suggested in the "Guide to the Expression of Uncertainty in Measurement" (GUM) published by ISO. Item Uncertainty VSWR(S11) 0.4 Gain -0.08dBi Lenze Technology Co.,LTD Tel:+86 0755-82031775;25332530 Fax:+86 0755-82713604 26c newspaper west tower, 6008 shennan Avenue,Futian District, Shenzhen City, GuangdongProvince,China GENERAL TEST CONFIGURATIONS 4.1 Test Condition Environment Parameter Selected Values During Tests Temperature Voltage Relative Humidity Normal Temperature, Normal Voltage 25°C N/A 51% (NTNV) 4.2 Test Equipment List Description Manufacturer Model Serial No. Cal. Date Cal. Due Vector Network Agilent E5071C MY46103472 2014.09.07 2015.09.06 Analyzer 5*5*5 Full Anechoic SATIMO 5*5*5 N/A 2014.09.05 2015.09.04 Chamber SG24 Multi-probe Antenna Measurement SATIMO SG24-L 1101855-0001 2014.10.25 2015.10.24 System 4.3 Test Setup Lenze Technology Co.,LTD Tel:+86 0755-82031775;25332530 Fax:+86 0755-82713604 26c newspaper west tower, 6008 shennan Avenue,Futian District, Shenzhen City, GuangdongProvince,China ANNEX A TEST RESULTS A.1 Gain and Efficiency Frequency Gain (dBi) Efficiency (%) 2402MHz -0.08 0.99 2441MHz -0.21 1.06 2480MHz -0.18 1.12 ANNEX B RADIATION PATTERN 3DPattern 2402MHZ 0 -1 -3 -6 -15 -30 Lenze Technology Co.,LTD Tel:+86 0755-82031775;25332530 Fax:+86 0755-82713604 26c newspaper west tower, 6008 shennan Avenue,Futian District, Shenzhen City, GuangdongProvince,China 2402MHZ 1D Radiation Pattern PHI =0 Phi=0 freq=2402MHz 0 -1 -3 -6 -15 -30 Lenze Technology Co.,LTD Tel:+86 0755-82031775;25332530 Fax:+86 0755-82713604 26c newspaper west tower, 6008 shennan Avenue,Futian District, Shenzhen City, GuangdongProvince,China PHI =90 THETA = 90 Phi=90 freq=2402MHz Theta=90 freq=2402MHz Lenze Technology Co.,LTD Tel:+86 0755-82031775;25332530 Fax:+86 0755-82713604 26c newspaper west tower, 6008 shennan Avenue,Futian District, Shenzhen City, GuangdongProvince,China ANNEX C TEST SETUP PHOTO ANNEX D EUT PHOTO Antenna shape
Page 1 of 41 Report No.: HK2408134586-E FCC Test Report Test Report On Behalf of Atomi Inc For Smart Tracker Model No.: AT2631-841152, AT2631, 841152 FCC ID: 2A6JY-AT2631 Prepared For: Atomi Inc 10 West 33 St - Suite 520 New York, NY 10001, United States Prepared By: Shenzhen HUAK Testing Technology Co., Ltd. 1-2/F., Building B2, Junfeng Zhongcheng Zhizao Innovation Park, Heping, Fuhai Street, Bao’an District, Shenzhen, Guangdong, China Date of Test: Aug. 09, 2024 ~ Aug. 16, 2024 Date of Report: Aug. 16, 2024 Report Number: HK2408134586-E Page 2 of 41 Report No.: HK2408134586-E Test Result Certification Applicant’s Name ................... : Atomi Inc Address .................................... : 10 West 33 St - Suite 520 New York, NY 10001, United States Manufacturer's Name ............. : ShenZhen RiShengHua Technology Co., Ltd. Address .................................... : Floor 2, building E1, qiangrong East Industrial Zone, No. 723, Zhoushi Road, Jiuwei community, Hangcheng street, Bao'an District, Shenzhen, China Product Description Trade Mark ................................. : Atomi Product Name ............................ : Smart Tracker Model and/or Type Reference .. : AT2631-841152, AT2631, 841152 Standards ................................ : 47 CFR FCC Part 15 Subpart C 15.247 KDB 558074 D01 15.247 Meas Guidance v05r02 ANSI C63.10: 2013 This publication may be reproduced in whole or in part for non-commercial purposes as long as the Shenzhen HUAK Testing Technology Co., Ltd. is acknowledged as copyright owner and source of the material. Shenzhen HUAK Testing Technology Co., Ltd. takes no responsibility for and will not assume liability for damages resulting from the reader's interpretation of the reproduced material due to its placement and context. Date of Test .............................................. : Date (s) of Performance of Tests ............... : Aug. 09, 2024 ~ Aug. 16, 2024 Date of Issue ............................................. : Aug. 16, 2024 Test Result ................................................. : Pass Testing Engineer Len Liao Technical Manager Sliver Wan Authorized Signatory Jason Zhou Page 3 of 41 Report No.: HK2408134586-E Contents Page 1 Test Summary ................................................................................................................................................ 5 1.1 Test Description ......................................................................................................................................... 5 1.2 Measurement Uncertainty ......................................................................................................................... 6 1.3 Information of the Test Laboratory ............................................................................................................ 6 2 General Information ....................................................................................................................................... 7 2.1 General Description of EUT ...................................................................................................................... 7 2.2 Description of Test Conditions .................................................................................................................. 9 2.3 Description of Test Setup ........................................................................................................................ 10 2.4 Description of Support Units .................................................................................................................... 11 3 Equipments List for All Test Items ............................................................................................................. 12 4 Test Result .................................................................................................................................................... 13 4.1 Antenna Requirement.............................................................................................................................. 13 4.2 Conduction Emissions Measurement ...................................................................................................... 14 4.3 Radiated Emissions Measurement .......................................................................................................... 17 4.4 Maximum Output Power Measurement ................................................................................................... 26 4.5 Power Spectral Density ........................................................................................................................... 27 4.6 6dB Bandwidth ........................................................................................................................................ 30 4.7 Occupied Bandwidth ................................................................................................................................ 33 4.8 Band Edge ............................................................................................................................................... 34 4.9 Conducted Spurious Emissions .............................................................................................................. 36 5 Test Setup Photos ....................................................................................................................................... 40 6 Photos of the EUT ........................................................................................................................................ 41 Page 4 of 41 Report No.: HK2408134586-E ** Modified History ** Revision Description Issued Data Remark Revision 1.0 Initial Test Report Release Aug. 16, 2024 Jason Zhou Page 5 of 41 Report No.: HK2408134586-E 1 Test Summary 1.1 Test Description Test Item Test Requirement Result Antenna Requirement §15.203/§15.247(b)(4) PASS Conducted Emission FCC Part 15.207 N/A Radiated Emissions FCC Pa…
Text truncated - open the document above for the full version.
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 2.40 GHz - 2.48 GHz | 3.49 mW |

Qi wireless Alarm Clock
Equipment Class
DCD - Part 15 Low Power Transmitter Below 1705 kHz