
Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
1 / 4 Remote Control Y3 Function Manual I. Description This product is a bicycle electric bell remote control. (1) Product Specifications: Model: Y3 Remote Control Input Voltage: 3V FCC ID: 2A6KL-Y3 Material: ABS Battery: 2032 Button Cell Execution Standard: A/ATS-001-2016 Battery Life: Approx. 8 months (varies with usage frequency) (2) User Interface (UI) - Three-button Remote Control Operation 2 / 4 Power On: Charge to activate for first-time use. Ringtone Selection: Press the [ ] button to switch between 6 available ringtones. Cycles through options. (Not available in armed mode). Volume Adjustment: Press the [+ -] buttons to adjust volume level. Three levels available: High, Medium, Low. Factory default is maximum volume. (Not available in armed mode). Bell/Locate Function: Press the remote button to sound the currently selected ringtone (useful for locating your bicycle). Press and hold to continue ringing for up to 5 seconds. Pairing: Main unit and remote are pre-paired by default. For special pairing needs: a. Remote Pairing Method: Connect USB charger. Within 30 seconds of charging, press and hold the remote's [+ -] buttons for about 5 seconds. After a 'Bi' sound, enter learning mode. Press any button on the new remote - two "Bi...Bi" sounds indicate successful pairing. Press the [+ -] buttons again to exit learning mode. b. Pairing with Paired Remote: Press and hold the [+ -] buttons on an already paired remote for about 5 seconds. After a 'Bi' sound, enter learning mode. Press any button on the new remote - two "Bi...Bi" sounds indicate successful pairing. Press the [+ -] buttons on the old remote to exit learning mode. c. Note: Main unit can store up to 4 remotes. If pairing a 5th remote, the first remote's code will be overwritten. 3 / 4 d. Code Deletion: Connect USB charger. Within 30 seconds of charging, press and hold the remote's [+ -] buttons for about 5 seconds. After a 'Bi' sound, enter learning mode. Press the [ ] button - one long "Bi..." sound indicates all remote codes have been cleared. e. Re-pairing: Refer to previous methods. Low Battery Alert: When main unit battery is low, pressing the "bell button" on the remote will trigger both normal alert tone and low battery alert tone "beep..." Charging: When charging is needed, open the USB-C port cover and connect using DC5V cable. Red indicator light beside USB port illuminates during charging; turns green when fully charged. Reset & Power Off: Reset to factory settings and power off after quality inspection. 4 / 4 FCC Radiation Exposure Statement: This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: —Reorient or relocate the receiving antenna. —Increase the separation between the equipment and receiver. —Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. —Consult the dealer or an experienced radio/TV technician for help. Radio Frequency Exposure Statement: This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment.
Attestation Statements (December 2, 2025) TO: SELLER HELPER INC. 1312 17th Street # 1298,Denver ,CO 80202,United States RE: Attestation Statements Part 2.911(d)(7) request for (FCCID: 2A6KL‐Y3) (Dongguan Antusi Electronic Technilogy Co,. Ltd.), the undersigned, hereby authorize( SELLER HELPER INC. ) to act as our designated U.S. agent for service of process,(Dongguan Antusi Electronic Technilogy Co,. Ltd.) accepts to maintain an agent for no less than one year after the grantee has terminated all marketing and importation or the conclusion of any Commission‐related proceeding involving the equipment. ( SELLER HELPER INC.) accepts the responsibility to act as designated U.S. agent for service of process,provides an agent for no less than one year after the Grantee has terminated all marketing and importation or the conclusion of any Commission‐related proceeding involving the equipment. Applicant Information: Company name:Dongguan Antusi Electronic Technilogy Co,. Ltd. Contact Name: Xijian Li Address:Address: B401, Qiaodeng Industrial Park, No.19 Chenwu East Road, Houjie, Dongguan, Guangdong, China Telephone No: +86 076922288560 Email: [email protected]_ FRN: 0032280315 U.S. Agent Information: Company Name: SELLER HELPER INC. Address: 1312 17th Street # 1298 , Denver , CO 80202 , United States Contact Name: Fairy Lee Telephone No: 01‐303‐3594188 Email: [email protected] FRN: 0033406737 Signature( 签字 ):Signature( 签字 ): Date ( 日期 ) : 2025.12.02 Date( 日期 ):2025.12.02 :
Shenzhen Accurate Technology Co., Ltd. No.: 2504Y23250E-RF EUT External Photos External Photos Page 1 / 3 External Photos remote control Shenzhen Accurate Technology Co., Ltd. No.: 2504Y23250E-RF EUT External Photos External Photos Page 2 / 3 Shenzhen Accurate Technology Co., Ltd. No.: 2504Y23250E-RF EUT External Photos External Photos Page 3 / 3 ***** END ***** ***** END ***** ***** END *****
Label Label location
Shenzhen Accurate Technology Co., Ltd. No.: 2504Y23250E-RF EUT Internal Photos Internal Photos Page 1 / 5 Internal Photos Shenzhen Accurate Technology Co., Ltd. No.: 2504Y23250E-RF EUT Internal Photos Internal Photos Page 2 / 5 Shenzhen Accurate Technology Co., Ltd. No.: 2504Y23250E-RF EUT Internal Photos Internal Photos Page 3 / 5 Shenzhen Accurate Technology Co., Ltd. No.: 2504Y23250E-RF EUT Internal Photos Internal Photos Page 4 / 5 Shenzhen Accurate Technology Co., Ltd. No.: 2504Y23250E-RF EUT Internal Photos Internal Photos Page 5 / 5 ANT ***** END *****
Note: This report must not be used by the customer to claim product certification, approval, or endorsement by A2LA, or any agency of the Federal Government. The information marked “#” is provided by the applicant, the laboratory is not responsible for its authenticity and this information can affect the validity of the result in the test report. Customer model name, addresses, names, trademarks etc. are included but no need marked. This report cannot be reproduced except in full, without prior written approval of the Company. Unless otherwise stated the results shown in this test report refer only to the sample(s) tested. This report is valid only with a valid digital signature. The digital signature may be available only under the Adobe software above version 7.0. Shenzhen Accurate Technology Co., Ltd. Floor 1, KuMaKe Building, Dongzhou Community, Guangming Street, Guangming District, Shenzhen, Guangdong, China. Tel: +86 755-26503290 Web: www.atc-lab.com Rev:A/4.0(2024/11/01) Page 1 of 6 TR-4-E-R062 TEST REPORT Applicant Name : Dongguan Antusi Electronic Technology Co., Ltd. Address : No. 5-1, Chenwu Jinying 2nd Street, Houjie Town, Dongguan City, Guangdong Province, China Report Number : 2504Y23250E-RF FCC ID: 2A6KL-Y3 Test Standard (s) 47 CFR §1.1307& §2.1093 Sample Description Product Type: Remote control Model No.: Y3 Trade Mark: ANTUSI Date Received: 2025-10-28 Report Date: 2025-12-02 Test Result: The EUT complied with the standards above. Prepared and Checked By: Approved By: Amanda Wei Bob.Liao EMC Engineer EMC Engineer Shenzhen Accurate Technology Co., Ltd. Report No.: 2504Y23250E-RF Rev:A/4.0(2024/11/01) Page 2 of 6 TR-4-E-R062 TABLE OF CONTENTS DOCUMENT REVISION HISTORY ................................................................................................................ 3 GENERAL INFORMATION ............................................................................................................................ 4 PRODUCT DESCRIPTION FOR EQUIPMENT UNDER TEST (EUT) ........................................................................ 4 OBJECTIVE ................................................................................................................................................... 4 TEST FACILITY .............................................................................................................................................. 4 RF EXPOSURE .............................................................................................................................................. 5 APPLICABLE STANDARD ................................................................................................................................. 5 TEST RESULT: .............................................................................................................................................. 5 EXHIBIT A-EUT PHOTOGRAPHS ................................................................................................................ 6 Shenzhen Accurate Technology Co., Ltd. Report No.: 2504Y23250E-RF Rev:A/4.0(2024/11/01) Page 3 of 6 TR-4-E-R062 DOCUMENT REVISION HISTORY Revision Number Report Number Description of Revision Date of Revision Rev.00 2504Y23250E-RF Original Report 2025-12-02 Shenzhen Accurate Technology Co., Ltd. Report No.: 2504Y23250E-RF Rev:A/4.0(2024/11/01) Page 4 of 6 TR-4-E-R062 GENERAL INFORMATION Product Description for Equipment under Test (EUT) Product Remote control Tested Model Y3 Frequency Range 433.92MHz Maximum E-field Strength 60.34dBuV/m@3m Antenna Specification # Internal Antenna Voltage Range # DC 3V from CR2032 battery Sample Serial Number 3BYL-2, 3BYL-3 (For RE Test) (Assigned by ATC, Shenzhen) Sample/EUT Status Good condition Objective This test report is in accordance with Part 1-Subpart I and Part 2-Subpart J, Radiofrequency Radiation Exposure of the Federal Communication Commission rules. The tests were performed in order to determine compliance with §1.1307 & §2.1093 rules. Test Facility The test site used by Shenzhen Accurate Technology Co., Ltd. to collect test data is located on the Floor 1, KuMaKe Building, Dongzhou Community, Guangming Street, Guangming District, Shenzhen, Guangdong, China. Accredited by American Association for Laboratory Accreditation (A2LA).The Certificate Number is 4297.01. Shenzhen Accurate Technology Co., Ltd. Report No.: 2504Y23250E-RF Rev:A/4.0(2024/11/01) Page 5 of 6 TR-4-E-R062 RF EXPOSURE Applicable Standard According to FCC §2.1093 and §1.1307(b), systems operating under the provisions of this section shall be operated in a manner that ensure that the public is not exposed to radio frequency energy level in excess of the Commission’s guideline. According to KDB 447498 D04 Interim General RF Exposure Guidance v01, clause 2.1.2 – 1-mW test Exemption: Per § 1.1307(b)(3)(i)(A), a single RF source is exempt RF device (from the requirement to show data demonstrating compliance to RF exposure limits, as previously mentioned) if the available maximum time-averaged power is no more than 1 mW, regardless of separation distance. This exemption applies to all operating configurations and exposure conditions, for the frequency range 100 kHz to 100 GHz, regardless of fixed, mobile, or portable device exposure conditions. This is a standalone exemption, and it cannot be applied in conjunction with any other test exemption. Test Result: For worst case: Mode Frequency Maximum Power 1-mW test Exemption (MHz) (dBm) (mW) SRD 433.92 -34.86 0.0003 Yes Note : E(dBuV/m)=EIRP(dBm)-95.2 for distance 3m Use the highest E-field strength(60.34 dBuV/m) for the evaluation, so the EIRP= 60.34 dBuV/m-95.2=-34.86 dBm Result: Compliance. Shenzhen Accurate Technology Co., Ltd. Report No.: 2504Y23250E-RF Rev:A/4.0(2024/11/01) Page 6 of 6 TR-4-E-R062 EXHIBIT A-EUT PHOTOGRAPHS Please refer to the Attachment No.1 2504Y23250E-RF EUT External Photos and Attachment No.2 2504Y23250E-RF EUT Internal Photos. ***** END OF REP…
Text truncated - open the document above for the full version.
Note: This report must not be used by the customer to claim product certification, approval, or endorsement by A2LA, or any agency of the Federal Government. The information marked “#” is provided by the applicant, the laboratory is not responsible for its authenticity and this information can affect the validity of the result in the test report. Customer model name, addresses, names, trademarks etc. are included but no need marked. This report cannot be reproduced except in full, without prior written approval of the Company. Unless otherwise stated the results shown in this test report refer only to the sample(s) tested. This report is valid only with a valid digital signature. The digital signature may be available only under the Adobe software above version 7.0. Shenzhen Accurate Technology Co., Ltd. Floor 1, KuMaKe Building, Dongzhou Community, Guangming Street, Guangming District, Shenzhen, Guangdong, China. Tel: +86 755-26503290 Web: www.atc-lab.com Rev:A/4.0(2024/11/01) Page 1 of 26 TR-4-E-R010 TEST REPORT Applicant Name: Dongguan Antusi Electronic Technology Co., Ltd. Address: No. 5-1, Chenwu Jinying 2nd Street, Houjie Town, Dongguan City, Guangdong Province, China Report Number: 2504Y23250E-RF-00A FCC ID: 2A6KL-Y3 Test Standard (s) FCC PART 15.231 Sample Description Product Name: Remote control Model No.: Y3 Trade Mark: ANTUSI Date Received: 2025-10-28 Report Date: 2025-12-02 Test Result: The EUT complied with the standards above. Prepared and Checked By: Approved By: Amanda Wei Bob.Liao EMC Engineer EMC Engineer Shenzhen Accurate Technology Co., Ltd. Report No.: 2504Y23250E-RF-00A Rev:A/4.0(2024/11/01) Page 2 of 26 TR-4-E-R010 TABLE OF CONTENTS DOCUMENT REVISION HISTORY ................................................................................................................ 3 GENERAL INFORMATION ............................................................................................................................ 4 PRODUCT DESCRIPTION FOR EQUIPMENT UNDER TEST (EUT) ........................................................................ 4 OBJECTIVE ................................................................................................................................................... 4 TEST METHODOLOGY .................................................................................................................................... 4 TEST FACILITY .............................................................................................................................................. 5 MEASUREMENT UNCERTAINTY ....................................................................................................................... 5 SYSTEM TEST CONFIGURATION ............................................................................................................... 6 DESCRIPTION OF TEST CONFIGURATION......................................................................................................... 6 EUT EXERCISE SOFTWARE AND POWER LEVEL # ............................................................................................ 6 SPECIAL ACCESSORIES ................................................................................................................................. 6 EQUIPMENT MODIFICATIONS .......................................................................................................................... 6 SUPPORT EQUIPMENT LIST AND DETAILS ....................................................................................................... 6 EXTERNAL I/O CABLE .................................................................................................................................... 6 BLOCK DIAGRAM OF TEST SETUP .................................................................................................................. 7 SUMMARY OF TEST RESULTS ................................................................................................................... 8 TEST EQUIPMENT LIST AND DETAILS ...................................................................................................... 9 ANTENNA REQUIREMENT......................................................................................................................... 10 APPLICABLE STANDARD ............................................................................................................................... 10 ANTENNA CONNECTOR CONSTRUCTION ....................................................................................................... 10 RADIATED EMISSIONS .............................................................................................................................. 11 APPLICABLE STANDARD ............................................................................................................................... 11 EUT SETUP ................................................................................................................................................ 11 EMI TEST RECEIVER & SPECTRUM ANALYZER SETUP .................................................................................. 13 TEST PROCEDURE ...................................................................................................................................... 13 CALCULATION ............................................................................................................................................. 13 TEST DATA ................................................................................................................................................. 14 DEACTIVATION TESTING .......................................................................................................................... 21 APPLICABLE STANDARD ............................................................................................................................... 21 TEST PROCEDURE ..............................................…
Text truncated - open the document above for the full version.
Shenzhen Accurate Technology Co., Ltd. No.: 2504Y23250E-RF-00A Test Photos Test Photos Page 1 / 2 Radiated Spurious Emissions Test View (9kHz-30MHz) Radiated Spurious Emissions Test View (30MHz- 1GHz) Shenzhen Accurate Technology Co., Ltd. No.: 2504Y23250E-RF-00A Test Photos Test Photos Page 2 / 2 Radiated Spurious Emissions Test View (Above 1GHz) ***** END *****
1312 17th Street # 1298 · Denver, Colorado, 80202 · United States
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15.231 | 433.92 MHz - 433.92 MHz | - |