Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
Instructions for use APP remote control bulb APP remote control bulb Nominal power: 9W Nominal lumen: 900LM Working voltage: AC85-265V Lamp size: φ6CM*12CM Lamp material: plastic-coated aluminum Remote control size: width 4cm* height 15.2cm* thickness 1.5cm Remote control built-in battery: 2 AA batteries 2*1.5V=3V Remark: Instructions for use Remark: 1: Please download the correct version of the mobile APP Remark: 1: Details of APP usage instructions Instructions for use Remark: 1: Different rooms can be added, and different lamps can be added in the room, which can be controlled uniformly or individually. 2: The master control can control all rooms. Instructions for use Remark: 1: Before pairing lamps, after adding rooms, enter the link of adding lamps. 2: Press the pairing button within 5 seconds after turning on the light to pair. 3: When pairing, the light flashes, indicating that the pairing is successful, if not, please turn off the light and turn it on again, and press the pairing button within 5 seconds to pair. Instructions for use Remark: 1: The remote control uses 2 AA batteries Instructions for use NOTE This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: -- Reorient or relocate the receiving antenna. -- Increase the separation between the equipment and receiver. -- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. -- Consult the dealer or an experienced radio/TV technician for help. Warning: changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment The devices has been evaluated to meet general RF exposure requirement, The device can be used in portable exposure condition without restriction ThisdevicecomplieswithPart15oftheFCCRules.Operationissubjecttothefollowingtwo conditions:(1)thisdevicemaynotcauseharmfulinterference,and(2)thisdevicemustaccept anyinterferencereceived,includinginterferencethatmaycauseundesiredoperation NOTE:ThisequipmenthasbeentestedandfoundtocomplywiththelimitsforaClassBdigital device,pursuanttoPart15oftheFCCRules.Theselimitsaredesignedtoprovidereasonable protectionagainstharmfulinterferenceinaresidentialinstallation.Thisequipmentgenerates, usesandcanradiateradiofrequencyenergyand,ifnotinstalledandusedinaccordancewiththe instructions,maycauseharmfulinterferencetoradiocommunications.However,thereisno guaranteethat interferencewillnotoccurinaparticularinstallation. Ifthisequipmentdoescauseharmfulinterferencetoradioortelevisionreception,whichcanbe determinedbyturningtheequipmentoffandon,theuserisencouragedtotrytocorrectthe interferencebyoneormoreofthefollowingmeasures: --Reorientorrelocatethereceivingantenna. --Increasetheseparationbetweentheequipmentandreceiver. --Connecttheequipmentintoanoutletonacircuitdifferentfromthattowhichthereceiveris connected. --Consultthedealeroranexperiencedradio/TVtechnicianforhelp. Warning:changesormodificationsnotexpresslyapprovedbythepartyresponsiblefor compliancecouldvoidtheuser'sauthoritytooperatetheequipment ThedeviceshasbeenevaluatedtomeetgeneralRFexposurerequirement,thedevicecanbe usedinportableexposureconditionwithoutestriction
Modeldifferencedeclarationletter DifferencesDescription WeZhongshanJingdaLightingElectricCo.,Ltd.state: Product: APP2.4GLEDLamps ModelName : JD-Q8W,JD3W,JD5W,JD7W,JD8W,JD9W,JD12W JD22W,JD24W,JD36W,JDWX8W,JDWX9W JDWX12W,JDWX24W,JD-WX36W Theaboveproductwithsamecircuit,PCBlayout,electricalparts,materialsandwiring structures,thematerialsofdecorativeaccessoriesissame,Theappearanceisthesamebut thecolorisdifferent Signatory Date:04-23.2022 <Signature> Name:ZhenJInZhou Title:Manager Company:ZhongshanJingdaLightingElectricCo.,Ltd Address:3rdFloor,No.17,Xinghong1stRoad,Hongmiao,Haizhou,GuzhenTown,ZhongshanCity, GuangdongProvince,China
C5266091_X8_Ed.1 1/1 ZhongshanJingdaLightingElectricCo.,Ltd. LetterofAuthorization Company:ZhongshanJingdaLightingElectricCo.,Ltd. Address:3rdFloor,No.17,Xinghong1stRoad,Hongmiao,Haizhou,GuzhenTown,Zhongshan City,GuangdongProvince,China ProductName:APP2.4GLEDLamps ModelNumber:JD-Q8W,JD3W,JD5W,JD7W,JD8W,JD9W,JD12WJD22W,JD24W, JD36W,JDWX8W,JDWX9WJDWX12W,JDWX24W,JD-WX36W FCCIdentifier:2A6KN-JD-Q8W WeauthorizeLGAITechnologicalCenterS.A.,RondadelaFontdelCarme,s/n, 08193Bellaterra,Spain,toactonourbehalfonallmattersconcerningthe abovenamedequipment. AnyindividualwithinLGAITechnologicalCenterS.A.isauthorizedtoactonour behalfandtakeactionontheapplication. WedeclarethatauthorizeLGAITechnologicalCenterS.A.,RondadelaFontdel Carme,s/n,08193Bellaterra,Spain,isallowedtoforwardallinformation relatedtotheapprovalprojecttotheFederalCommunicationCommissionand todiscussanyissuesconcerningtheapprovalapplication.Anyandallacts carriedoutbyLGAITechnologicalCenterS.A.onourbehalfshallhavethe sameeffectasactsofourown. Name:ZhenJInZhouDate:24Apr,2022 Title:Manager Signatureofapplicant:
C5266091_X10_Ed.2 1/1 ZhongshanJingdaLightingElectricCo.,Ltd. OfficeofEngineeringTechnology FederalCommunicationsCommission 7435OaklandMillsRoad Columbia,MD21046 Date:24Apr ,2022 Subject:RequestforConfidentiality FCCID:2A6KN-JD-Q8W ToWhomItMayConcern, PursuanttotheprovisionsofSections0.457and0.459ofCommission'srules (47CFR0.457,0.459),wearerequestingtheCommissiontowithholdthefollowing attachment(s)asconfidentialdocumentfrompublicdisclosure. ExhibitsLong-Term Confidentiality Short-Term Confidentiality NOTE2 IDLabel/LocationNoNo AttestationStatementNoNo ExternalPhotosNo ☐ BlockDiagram ☒☐ Schematics ☒☐ TestReportNoNo TestSetupPhotosNo ☐ User’sManual ☐ NOTE 1 ☐ InternalPhotos ☐ NOTE 1 ☐ PartsList/TuneUp ☐☐ RFExposureInfoNoNo OperationalDescription ☒☐ CoverLetter(s)NoNo SDRSoftware/SecurityInfo ☐ No NOTE1:Long-TermConfidentialitymaybepermittedunderspecialconditions(SeeII.LONG-TERM CONFIDENTIALITY,Section3ofKDB726920,uselastinforce) NOTE2:Short-TermConfidentialitycanberequestedforamaximumof180daysfromthedateofthegrant. Abovementioneddocumentcontainsdetailedsystemandequipmentdescriptionare consideredasproprietaryinformationinoperationoftheequipment.Thepublic disclosureofabovedocumentsmightbeharmfultoourcompanyandwouldgive competitoranunfairadvantageinthemarket. C5266091_X10_Ed.2 1/1 Incaseofshort-termConfidentiality,theapplicantrequeststheexhibitsselected abovearewithheldfrompublicviewforaperiodof______daysfromthedateofthe GrantofEquipmentAuthorizationandpriortomarketing. Itisourunderstandingthatallmeasurementtestreports,FCCIDlabelformatand correspondentduringcertificationreviewprocesscannotbegrantedasconfidential documentsandthoseinformationwillbeavailableforpublicreviewoncethegrantof equipmentauthorizationisissued. Sincerely, Signature: Name: ZhenJInZhou Title:Manager
Page1of3ReportNo.:FCS202204060 Externalphotos Photo1 Photo2 Page2of3ReportNo.:FCS202204060 Photo3 Photo4 Page3of3ReportNo.:FCS202204060 Photo5 Photo6
LabelandLabelLocation FCCID:2A6KN-JD-Q8W L*W:8mm*4mm Blackfontonawhitelabel
Page1of3ReportNo.:FCS202204060 Internalphotos Photo1 Photo2 Page2of3ReportNo.:FCS202204060 Photo3 Photo4 Page3of3ReportNo.:FCS202204060 Photo5 PCBANTENNA A8125M0
FCCTestReport ReportNo:FCS202204060W01 Issuedfor Applicant:ZhongshanJingdaLightingElectricCo.,Ltd. Address: 3rdFloor,No.17,Xinghong1stRoad,Hongmiao, Haizhou,GuzhenTown,ZhongshanCity,Guangdong Province,China ProductName:APP2.4GLEDLamps BrandName:N/A ModelName:JD-Q8W SeriesModel: JD3W,JD5W,JD7W,JD8W,JD9W,JD12W,JD22W JD24W,JD36W,JDWX8W,JDWX9W JDWX12W,JDWX24W,JD-WX36W FCCID:2A6KN-JD-Q8W IssuedBy:FluxComplianceServiceLaboratory Add:Room105FloorBaohaoTechnologyBuilding1NO.15GongyeWestRoadHi-Tech Industrial,SongshanlakeDongguan Tel:769-27280901Fax:769-27280901http://www.fcs-lab.com Page2of34ReportNo.:FCS202204060W01 FluxComplianceServiceLaboratory Room105FloorBaohaoTechnologyBuilding1NO.15GongyeWestRoadHi-TechIndustrial,SongshanlakeDongguan Tel:769-27280901Fax:769-27280901http://www.fcs-lab.com TESTRESULTCERTIFICATION Applicant’sName......................:ZhongshanJingdaLightingElectricCo.,Ltd. Address......................................: 3rdFloor,No.17,Xinghong1stRoad,Hongmiao,Haizhou,Guzhen Town,ZhongshanCity,GuangdongProvince,China Manufacture'sName ................ :ZhongshanJingdaLightingElectricCo.,Ltd. Address ...................................... : 3rdFloor,No.17,Xinghong1stRoad,Hongmiao,Haizhou,Guzhen Town,ZhongshanCity,GuangdongProvince,China ProductDescription ProductName...........................: APP2.4GLEDLamps BrandName ............................. : N/A ModelName..............................: JD-Q8W SeriesModel .............................. :Refertopage1 TestStandards..........................:FCCRulesandRegulationsPart15SubpartC,Section249 TestProcedure .......................... :ANSIC63.10:2013 ThisdevicedescribedabovehasbeentestedFCS,thetestresultsshowthattheequipmentundertest (EUT)isincompliancewiththeFCCrequirements.Anditisapplicableonlytothetestedsample identifiedinthereport. Thisreportshallnotbereproducedexceptinfull,withoutthewrittenapprovalofFCS,thisdocument maybealteredorrevisedbyFCS,personalonly,andshallbenotedintherevisionofthedocument.. DateofTest .................................. : Date(s)ofperformanceoftests.:13Apr,2022~28Apr,2022 DateofIssue.................................:28Apr,2022 TestResult....................................:Pass Testedby: (ScottShen) Reviewedby : (DukeQian) Approvedby: (JackWang) Page3of34ReportNo.:FCS202204060W01 FluxComplianceServiceLaboratory Room105FloorBaohaoTechnologyBuilding1NO.15GongyeWestRoadHi-TechIndustrial,SongshanlakeDongguan Tel:769-27280901Fax:769-27280901http://www.fcs-lab.com TableofContentsPage 1.SUMMARYOFTESTRESULTS5 1.1TESTFACTORY6 1.2MEASUREMENTUNCERTAINTY6 2.GENERALINFORMATION7 2.1GENERALDESCRIPTIONOFTHEEUT7 2.2DESCRIPTIONOFTHETESTMODES9 2.3DESCRIPTIONOFNECESSARYACCESSORIESANDSUPPORTUNITS10 2.4EQUIPMENTSLIST11 3CONDUCTEDEMISSIONMEASUREMENT12 3.1LIMIT12 3.2TESTPROCEDURE12 3.3TESTSETUP13 3.4TESTRESULTS14 4.RADIATEDEMISSIONMEASUREMENT16 4.1LIMIT16 4.2TESTPROCEDURE17 4.3TESTSETUP18 4.4TESTRESULTS19 5.BANDEDGETEST25 5.1LIMIT25 5.2TESTPROCEDURE25 5.3TESTSETUP26 5.4TESTRESULTS27 6.20DBBANDWIDTHTEST28 6.1LIMIT28 6.2TESTPROCEDURE28 6.3TESTSETUP28 6.4TESTRESULTS29 7.ANTENNAREQUIREMENT31 7.1STANDARDREQUIREMENT31 7.2EUTANTENNA31 Page4of34ReportNo.:FCS202204060W01 FluxComplianceServiceLaboratory Room105FloorBaohaoTechnologyBuilding1NO.15GongyeWestRoadHi-TechIndustrial,SongshanlakeDongguan Tel:769-27280901Fax:769-27280901http://www.fcs-lab.com RevisionHistory Rev.IssueDateEffectPageContents 0028Apr.2022N/AInitialIssue Page5of34ReportNo.:FCS202204060W01 FluxComplianceServiceLaboratory Room105FloorBaohaoTechnologyBuilding1NO.15GongyeWestRoadHi-TechIndustrial,SongshanlakeDongguan Tel:769-27280901Fax:769-27280901http://www.fcs-lab.com 1.SUMMARYOFTESTRESULTS FCCPart15.249,SubpartC Standard Section TestItemJudgmentRemark 15.207ConductedEmissionPASS-- 15.205(a),15.209(a), 15.249(a),15.249(c) RadiatedSpuriousEmissionPASS-- 15.209FieldstrengthoffundamentalPASS 15.249(d)BandEdgeEmissionPASS-- 15.215(c)20dBBandwidthPASS-- 15.203AntennaRequirementPASS-- NOTE: (1)”N/A”denotestestisnotapplicableinthisTestReport (2)AlltestsareaccordingtoANSIC63.10-2013 Page6of34ReportNo.:FCS202204060W01 FluxComplianceServiceLaboratory Room105FloorBaohaoTechnologyBuilding1NO.15GongyeWestRoadHi-TechIndustrial,SongshanlakeDongguan Tel:769-27280901Fax:769-27280901http://www.fcs-lab.com 1.1TESTINGLABORATORY CompanyName:FluxComplianceServiceLaboratory Address: Room105FloorBaohaoTechnologyBuilding1NO.15Gongye WestRoadHi-TechIndustrial,SongshanlakeDongguan Telephone:+86-769-27280901 Fax:+86-769-27280901 LaborayAccreditations FCCTestFirmRegistrationNumber:514908 CNASNumber:L15566 Designationnumber:CN0127 A2LAaccreditationnumber:5545.01 ISEDNumber:25801 1.2MEASUREMENTUNCERTAINTY Thereporteduncertaintyofmeasurementy±U,whereexpendeduncertaintyUisbasedona standarduncertaintymultipliedbyacoveragefactorofk=2,providingalevelofconfidenceof approximately95%. No.ItemUncertainty 1RFoutputpower,conducted±0.71dB 2UnwantedEmissions,conducted±2.98dB 3ConductedEmission(9KHz-150KHz) ±4.13dB 4ConductedEmission(150KHz-30MHz)±4.74dB 5Allemissions,radiated(9KHz-30MHz)±3.1dB 6Allemissions,radiated(<1G)30MHz-1000MHz ±3.2dB 7Allemissions,radiated(1GHz-18GHz)±3.66dB 8Allemissions,radiated(18GHz-40GHz) ±4.31dB 9Occupiedbandwidth4(%) Page7of34ReportNo.:FCS202204060W01 FluxComplianceServiceLaboratory Room105FloorBaohaoTechnologyBuilding1NO.15GongyeWestRoadHi-TechIndustrial,SongshanlakeDongguan Tel:769-27280901Fax:769-27280901http://www.fcs-lab.com 2.GENERALINFORMATION 2.1GENERALDESCRIPTIONOFTHEEUT ProductName APP2.4GLEDLamps TradeName N/A ModelName JD-Q8W SeriesModelRefertopage1 ModelDifference Theaboveproductwithsamecircuit,PCBlayout, electricalparts,materialsandwiringstructures,the materialsofdecorativeaccessoriesissame,The appearanceisthesamebutthecolorisdifferent ChannelList PleaserefertotheNote2. BT Frequency:2402-2480MHz Modulation:GFSK Channelnumber:40CH Datarate:1Mbps,2Mbps AntennaType PCBantennaChipantennaFPCantenna PowerSupply Input:AC85-265V BatteryN/A Hardwareversionnumb…
Text truncated - open the document above for the full version.
Page 1 of2ReportNo.:FCS202204060 Blow1GHzforradiatedemissiontestsetup Above1GHzforradiatedemissiontestsetup Page 2 of2ReportNo.:FCS202204060 Conductedemissiontestsetup
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 2.40 GHz - 2.48 GHz | - |