FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. ENVY Health Technology (Dongguan) Co., Ltd./
  3. 2A6MY-WS-NV792X-1

2A6MY-WS-NV792X-1Sex massage machine

ENVY Health Technology (Dongguan) Co., Ltd.
Sex massage machine - FCC ID 2A6MY-WS-NV792X-1 - ENVY Health Technology (Dongguan) Co., Ltd.
Click to zoom

Application Details

Equipment Class
DXX - Part 15 Low Power Communication Device Transmitter
Date of Grant
Aug 27, 2026
Application Purpose
Original Equipment
Equipment Note
Sex massage machine
Frequency Range
2402.00000000 - 2480.00000000
Company
ENVY Health Technology (Dongguan) Co., Ltd.
Country
China

Documents & Files

Select a file to view

Users Manual

↗

Attestation Statements

↗
↗

Cover Letter(s)

↗
↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗
↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

Thank you so much for your purchase OPERATING INSTRUCTIONS 1 2 4 ①Attachment Connector ②Motor In sae ③Suction Cup ④power pack ⑤Base Plate ⑥Rotary Knob ⑦Handle ⑧remote controls 1.Press all of ⑤ to mount machine to smooth surfaces. 2. Install one of included attachments onto ①. 3. Rotate ⑥ to adjust the angel of the thrusting position. 4. Plug ④ in Power, turn on the remote controls. 7 6 3 5 2 Tap to turn on while in standby mode; this controls changes in frequency. While in standby mode, tap to turn it on and adjust the speed. The device is in standby mode by default. Tap to activate it. After it starts up, tap to pause it, and press and hold to turn it off. 3 on/off button 6 speeds 6 modes Remove and clean the accessories after each use. Use a mild detergent and a damp cloth, or follow the separate instructions in the attachment. Do not use irritating chemicals or abrasive cleaning pads unless otherwise specied. Remove any dust or other substances that may accumulate on the machine with a soft cloth dipped in a mild detergent solution. Do not use harsh chemicals or abrasive cleaning pads. Check the moving and fixed parts regularly for signs of wear. Before continuing to use, repair, adjust or replace any parts that may be loose. 0~24W 24V(60W) 6speed+6modes Thrust 50-55dB 2.36 inches (6 cm) About 135 degrees 37.8×15.3×16.8 cm ABS plastic and metals + TPE 100V~240V DC 3~24V Power Motor Mode Product function Noise Extension Distance Adjusting Angle Size Material Input Output 4 Remote control voltage DC 3V Danger! This product is not waterproof, please do not wade. Attention! a. Use only on a flat and stable surface to prevent damage to your machine.Cause injury or damage. Check the normal operation of the machine before each use.If your machine can't run as expected, please stop using parallel connection immediate- ly.Department of store customer service help. b. in order to achieve the best effect, according to the need to use lubricant with accessories. c. in order to achieve the best results, please clean after each use. Don't rinse. d. Unplug the machine after each use to ensure a long service life. 5 FCC Caution. This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Any Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: -Reorient or relocate the receiving antenna. -Increase the separation between the equipment and receiver. -Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. -Consult the dealer or an experienced radio/TV technician for help. The device has been evaluated to meet general RF exposure requirement. The device can be used in portable exposure condition without restriction. 6

Attestation Statements

Rev1/26/2023 ENVYHealthTechnology(Dongguan)Co.,Ltd. FederalCommunicationsCommission AuthorizationandEvaluationDivision 7435OaklandMillsRoad Columbia,MD21046 USA Date:8-20-2026 Ref:AttestationStatementsPart2.911(d)(5)(i)Filing FCCID:2A6MY-WS-NV792X-1 ENVYHealthTechnology(Dongguan)Co.,Ltd.certifiesthattheequipmentforwhichauthorizationis soughtisnot“covered”equipmentprohibitedfromreceivinganequipmentauthorizationpursuantto section2.903oftheFCCrules. ENVYHealthTechnology(Dongguan)Co.,Ltd.certifiesthattheequipmentforwhichauthorizationis soughtdoesnotincludecybersecurityoranti-virussoftwareproducedorprovidedbyKasperskyLab,Inc. oranyofitssuccessorsandassignees,includingequipmentwithintegratedKasperskyLab,Inc.(oranyof itssuccessorsandassignees)cybersecurityoranti-virussoftwarepursuanttoDA-24-886andKDB 986446D01CoveredEquipmentGuidancesectionB(2a). Deviceisinherentlycompliantbasedonhardwarelimitationsorsoftwarecontrols. or ASoftwareBillofMaterials(SBOM)isprovidedtotheTCBforreview,and Theend-userorthirdpartiescannotinstalladditionalsoftwareonthisdevice. Sincerely, (Applicantsignature) (Applicantprintedname)GaoLu Rev1/26/2023 ENVYHealthTechnology(Dongguan)Co.,Ltd. FederalCommunicationsCommission AuthorizationandEvaluationDivision 7435OaklandMillsRoad Columbia,MD21046 USA Date:8-20-2026 Ref:AttestationStatementsPart2.911(d)(5)(ii)Filing FCCID:2A6MY-WS-NV792X-1 ENVYHealthTechnology(Dongguan)Co.,Ltd.certifiesthat,asofthedateofthefilingoftheapplication, theapplicantisnotidentifiedontheCoveredList(asaspecificallynamedentityoranyofitssubsidiaries oraffiliates)asanentityproducing“covered”equipment. Sincerely, (Applicantsignature) (Applicantprintedname) GaoLu

Attestation Statements

E N V Y H e a l t h T e c h n o l o g y ( D o n gg u an ) C o . , L t d . RM 303 , B l d g 2 , 2 D i n g wu Z h e n x i n g Y i L u , D o n g k e n g T o w n , D o n gg u a n , G u an g d o n g , C hi na U . s. A g e n t L e t t er o f A tt e s t a t i on T o : F e d e ra l C o m m u n i c a t i o n s C o m m i s s i o n 74 3 5 O a kl a n d M i l l s R oa d , C o l u m b i a , M D 2 1 0 4 6 , U S D a t e : A u g . 20 , 202 6 A R e f : A tt e s t a t i o n S t a t e m e n t - P a r t 2 . 9 11 ( d )( 7 ) f i li n g F CC I D : 2 A 6 M Y - W S - N V 7 92 X - 1 E NVY H ea l t h T e c h n o l o g y ( D o n gg u a n ) C o . , L t d . ( t h e a p p l i ca n t " ) ce r t i f i es t h a t , a s o f t h e d a t e o f t h e f l i n g o f t h e a pp l i c a t i o n , [ L O B OS I O WA I N C ] ( " t h e a g e n t " ) i s o u r d es i g na t e d U . S . a g e n t f o r se r v i ce o f p r oce ss f o r t h e a b o v e r e f e r e n ce F CC I D . T h e a pp li c a n t a cc e p t s t o m a i n t a i n a n a g e n t f o r se rv i c e o f p r ocess i n t h e U n i t e d S t a t es f o r n o l ess t h a n o n e y e a r a f t e r e i t h e r t h e g r a n t ee h a s p e r m a n e n t l y t e rm i na t e d a l l m a r k e t i n g an d i m p o r t a t i o n o f t h e a pp li c a bl e e q u i p m e n t w i t hi n t h e U . S . , o r t h e co n c l u s i o n o f an y C o mm i ss i o n - r e l a t e d a d m i n i s t r a t i v e o r j u d i c i a l p r ocee d i n g i nv o l v i n g t h e e q u i p m e n t , w hi c h e v e r i s l a t e r . T h e a p p li c an t f u r t h e r a c k n o w l e d g es i t i s o u r r es p o n s ib i li t y t o i n f o rm t h e F CC w h e n e v e r t h e a g e n t i n f o rma t i o n c h an g es . [ L O B OS I O WA IN C ]( " t h e a g e n t ) u n d e r s t an d i t i s t h e a g e n t ' s o bl i g a t i o n t o acce p t se r v i ce o f p r ocess i n t h e U n i t e d S t a t es f o r m a t t e r s r e l a t e d t o t h e a p p li c a bl e e q u i p m e n t , an d a t t h e p h y s i c a l U . S . a d d r ess an d e m a il a d d r ess . D es i g nate d U . S . A g ent C o m p a n y N a m e : L O B OS I O W A I N C FR N : 0036 41 396 1 A dd r ess : 4 623 B i tt e r c r ee k D r C o l o r a d o S p r i n g s co 80922 U s S i g na t u r e : C o n t a c t P e r so n : H a r l e y L i T e l : ( 8 1 8 ) 8 1 8 - 053 8 A pp li c a n t E m a il : i n f o @ l o b os - l o w a . co m C o m p a n y N a m e : E N VY H ea l t h T e c h n o l o g y ( D o n gg u a n ) C o . , L t d . FR N : 0 0 3 2 306 1 4 4 A d d r ess : RM 303 , B l d g 2 , 2 D i n g w u Z h e n x i n g Y i L u , D o n g k e n g T o w n , D o n gg u a n , G u a n g d o n g , C h i n a S i g n a t ur e : C ontact P erson : G ao L u T e l : 1 80 2 5 9 2 8 4 0 1 E m a il : g a o . I @ n v t o y z . co m

Cover Letter(s)

ENVYHealthTechnology(Dongguan)Co.,Ltd. Date:8-20-2026 ProductModelNumber:Sexmassagemachine FCCID : 2A6MY-WS-NV792X-1 Towhomitmayconcern, Re:ProductCertificationRepresentativeAuthorizationLetter WeauthorizeQAILaboratoriesLtd.3980NorthFraserWay,BurnabyB.C. CanadaV5J5K5toactonourbehalfonallmattersconcerningtheabove namedequipment. Thisshallincludethefollowing: Testing Approvalapplicationsandprocedures WedeclarethatQAILaboratoriesLtd.isallowedtoforwardallinformation relatedtotheapprovalprojecttotheappliedcertificationbodyandtothe notificationentitiesandtodiscussanyissuesconcerningtheapproval application.AnyandallactscarriedoutbyQAILaboratoriesLtd.onour behalfshallhavethesameeffectasactsofourown. By:GaoLu ContactListedonFCCWesbite (Applicantsignature) Title:QualityManager Email:[email protected] Telephone:18025928401 Onbehalfof:ENVYHealthTechnology(Dongguan)Co.,Ltd.

Cover Letter(s)

ENVYHealthTechnology(Dongguan)Co.,Ltd. OfficeofEngineeringTechnology FederalCommunicationsCommission 7435OaklandMillsRoad Columbia,MD21046 USA Date:August25,2026 Subject;RequestforConfidentiality FCCID:2A6MY-WS-NV792X-1 ToWhomItMayConcern, PursuanttotheprovisionsoftheCommission’srulesTitle47Sections§0.457and§0.459,we arerequestingtheCommissiontowithholdthefollowingattachment(s)asconfidential documentsfrompublicdisclosureindefinitely. Thesedocumentscontaindetailedsystemandequipmentdescriptionsandareconsideredas proprietaryinformationinoperationoftheequipment.Thepublicdisclosureofthese documentsmightbeharmfultoourcompanyandwouldgivecompetitorsanunfairadvantage inthemarket. SchematicDiagram BlockDiagram PartsList OperationalDescription Tune-upProcedure SoftwareSecurityRequirementsforUNIIdevices Inadditionaltoabovementioneddocuments,inordertocomplywiththemarketingregulations inTitle47CFR§2.803andtheimportationrulesinTitle47CFR§2.1204,whileensuringthat businesssensitiveinformationremainsconfidentialuntiltheactualmarketingofnewly authorizeddevices,werequestShortTermConfidentialityofthefollowingattachment(s); ExternalPhotos TestSetupPhotos InternalPhotos UserManual For45days,pursuanttoPublicNoticeDA04-1705. OR For180dayspursuanttoKDB726920D01. Itisourunderstandingthatallmeasurementtestreports,FCCIDlabelformatand correspondenceduringthecertificationreviewprocesscannotbegrantedasconfidential documentsandthisinformationwillbeavailableforpublicreviewoncethegrantofequipment authorizationisissued. Sincerely, Signature: Name:GaoLu Title:QualityManager

Cover Letter(s)

ENVYHealthTechnology(Dongguan)Co.,Ltd. ProductSimilarityDeclaration EUTDescription:Sexmassagemachine ModelNo.:WS-NV792X-1 SeriesModel:WS-NV303X,WS-NV146X,WS-NV154X,WS-NV566X, WS-NV597X,WS-NV637X,WS-NV598X,WS-NV181X, WS-NV597X,WS-NV168X We(ENVYHealthTechnology(Dongguan)Co.,Ltd.)hereby statethatallthemodelsareelectricalidenticalincludingthesame softwareparameterandhardwaredesign(i.e.,circuitdesign,PCB Layout,RFmodule/circuit,antennatype(s)andantennalocation, componentsonPCB,etc.,),samemechanicalstructureand design(includingproductenclosure,materials,etc.,),theonly differenceisthemodelnameandcolour. Signature: Name:GaoLu Title:QualityManager Place,date:Aug.20,2026

External Photos

Page1of4FCS202608038 Externalphotos Photo1 Photo2 Page2of4FCS202608038 Photo3 Photo4 Page3of4FCS202608038 Photo5 Photo6 Page4of4FCS202608038 Photo7

ID Label/Location Info

LabelandLabelLocation FCCID:2A6MY-WS-NV792X-1 Thisdevicecomplieswithpart15oftheFCCRules. Operationissubjecttothefollowingtwoconditions: (1)Thisdevicemaynotcauseharmfulinterference,and (2)thisdevicemustacceptanyinterferencereceived, includinginterferencethatmaycauseundesired operation. L*W:3cm*2cm labelandWhitefont

Internal Photos

Page1of3ReportNo.:FCS202608038 Internalphotos Photo1 Photo2 ANT Page2of3ReportNo.:FCS202608038 Photo3 Photo4

RF Exposure Info

Page1of2ReportNo.:FCS202608038 FluxComplianceServiceLaboratory Room105FloorBaohaoTechnologyBuilding1NO.15GongyeWestRoadHi-TechIndustrial,SongshanlakeDongguan Tel:769-27280901Fax:769-27280901http://www.FCS-lab.com FCCRFExposure EUTDescription:Sexmassagemachine ModelNo.: WS-NV792X-1 SeriesModel: WS-NV303X,WS-NV146X,WS-NV154X,WS-NV566X,WS-NV597X, WS-NV637X,WS-NV598X,WS-NV181X,WS-NV597X,WS-NV168X FCCID:2A6MY-WS-NV792X-1 Equipmenttype:portabledevice AccordingtoKDB447498D01GeneralRFExposureGuidancev06andpart2.1093,Unlessspecifically requiredbythepublishedRFexposureKDBprocedures,standalone1-gheadorbodyand10-gextremity SARevaluationforgeneralpopulationexposureconditions,bymeasurementornumenicalsimulation,is notrequiredwhenthecorrespondingSARTestExclusionThresholdcondition(s),listedbelow,is(are) satisfied. For100MHzto6GHzandtestseparationdistances<50mm,the1-gand10-gSARtestexclusion thresholdsaredeterminedbythefollowing: f(GHz)istheRFchanneltransmitfrequencyinGHz.Theresultisroundedtoonedecimalplacefor comparison [(max.powerofchannel,includingtune-uptolerance,mW)/(mintestseparation Distance,mm)][sqrt(f(GHz))]<3.0for1-gSAR,ands7.5for10-gextremitySAR,where PoweranddistanceareroundedtothenearestmWandmmbeforecalculation LimitsforMaximumPermissibleExposure(MPE) TestResultofRFExposureEvaluation EIRP=EMeas+20log(dmeas)-104.7 EIRPistheequivalentisotropicallyradiatedpower, EMeasindBmisthefieldstrengthoftheemissionatthemeasurementdistance,indBu V/m dMeasisthemeasurementdistance,inm 2.4G-SRD Frequency (MHz) Fieldstrength (dBuV/m) EIRP(dBm) Max tune-up(mW) Min. distance(mm) Calc. thresholds limit 2402 77.07-18.08760.0155 5.000.00483.0000 2440 76.27-18.88760.0129 5.000.00403.0000 2480 77.10-18.05760.0156 5.000.00493.0000 Conclusion:NoSARisrequired

Test Report

FCCTestReport ReportNo:FCS202608038W01 Issuedfor Applicant:EENVYHealthTechnology(Dongguan)Co.,Ltd. Address: RM303,Bldg2,2DingwuZhenxingYiLu,Dongkeng Town,Dongguan,Guangdong,China ProductName:Sexmassagemachine BrandName:N/A ModelName:WS-NV792X-1 SeriesModel: WS-NV303X,WS-NV146X,WS-NV154X,WS-NV566X, WS-NV597X,WS-NV637X,WS-NV598X,WS-NV181X, WS-NV597X,WS-NV168X FCCID:2A6MY-WS-NV792X-1 IssuedBy:FluxComplianceServiceLaboratory Add:Room105FloorBaohaoTechnologyBuilding1NO.15GongyeWestRoadHi-Tech Industrial,SongshanlakeDongguan Tel:0769-27280901Fax:0769-27280901http://www.fcs-lab.com Page2of27ReportNo.:FCS202608038W01 FluxComplianceServiceLaboratory Room105FloorBaohaoTechnologyBuilding1NO.15GongyeWestRoadHi-TechIndustrial,SongshanlakeDongguan Tel:0769-27280901Fax:0769-27280901http://www.fcs-lab.com TESTRESULTCERTIFICATION ApplicantName.........................: ENVYHealthTechnology(Dongguan)Co.,Ltd. Address ...................................... : RM303,Bldg2,2DingwuZhenxingYiLu,DongkengTown,Dongguan, Guangdong,China ManufactureName ................... : ENVYHealthTechnology(Dongguan)Co.,Ltd. Address......................................: RM303,Bldg2,2DingwuZhenxingYiLu,DongkengTown,Dongguan, Guangdong,China ProductDescription ProductName...........................: Sexmassagemachine BrandName ............................. : N/A ModelName .............................. : WS-NV792X-1 SeriesModel .............................. : pleaserefertothefirstpageofthereport TestStandards..........................: FCCRulesandRegulationsPart15SubpartC,Section249 TestProcedure .......................... : ANSIC63.10-2020+Cor.1-2023+C63.10a-2024+Erratato C63.10a-2024 ThisdevicedescribedabovehasbeentestedFCS,thetestresultsshowthattheequipmentunder test(EUT)isincompliancewiththeFCCrequirements.Anditisapplicableonlytothetestedsample identifiedinthereport. Thisreportshallnotbereproducedexceptinfull,withoutthewrittenapprovalofFCS,thisdocument maybealteredorrevisedbyFCS,personalonly,andshallbenotedintherevisionofthedocument.. DateofTest .................................. : Date(s)ofperformanceoftests.:Aug.4,2026~Aug.13,2026 DateofIssue.................................:Aug.13,2026 TestResult.....................................:Pass Testedby: (orangeOuYang) Reviewedby : (JaydneLi) Approvedby: (JackWang) Page3of27ReportNo.:FCS202608038W01 FluxComplianceServiceLaboratory Room105FloorBaohaoTechnologyBuilding1NO.15GongyeWestRoadHi-TechIndustrial,SongshanlakeDongguan Tel:0769-27280901Fax:0769-27280901http://www.fcs-lab.com TableofContentsPage 1.SUMMARYOFTESTRESULTS..............................................................................................5 1.1TESTFACTORY................................................................................................................6 1.2MEASUREMENTUNCERTAINTY.....................................................................................6 2.GENERALINFORMATION.......................................................................................................7 2.1GENERALDESCRIPTIONOFTHEEUT..........................................................................7 2.2DESCRIPTIONOFTHETESTMODES............................................................................9 2.3DESCRIPTIONOFNECESSARYACCESSORIESANDSUPPORTUNITS................10 2.4EQUIPMENTSLIST.........................................................................................................11 3CONDUCTEDEMISSIONMEASUREMENT..........................................................................12 3.1LIMIT................................................................................................................................12 3.2TESTPROCEDURE........................................................................................................12 3.3TESTSETUP...................................................................................................................13 3.4TESTRESULTS...............................................................................................................13 4.RADIATEDEMISSIONMEASUREMENT..............................................................................13 4.1LIMIT................................................................................................................................14 4.2TESTPROCEDURE........................................................................................................15 4.3TESTSETUP...................................................................................................................16 5.BANDEDGETEST.................................................................................................................22 5.1LIMIT................................................................................................................................22 5.2TESTPROCEDURE........................................................................................................22 5.3TESTSETUP...................................................................................................................22 5.4TESTRESULTS...............................................................................................................23 6.20DBBANDWIDTHTEST.....................................................................................................23 6.1LIMIT................................................................................................................................24 6.2TESTPROCEDURE........................................................................................................24 6.3TESTSETUP...................................................................................................................24 6.4TESTRESULTS...............................................................................................................25 7.ANTENNAREQUIREMENT...................................................................................................27 7.1STANDARDREQ…

Text truncated - open the document above for the full version.

Test Report

—1— SPECIFICATIONFORAPPROVAL CUSPARTNO:WS-NV792X-1 PARTNAME:Sexmassagemachine —2— Contents 1.Performanceparameter.................................................................................................3 2.Appearance....................................................................................................................4 3.EUTsetupphotooffreespaceOTAtesting.................................................................4 4.VSWRparameters.........................................................................................................6 5.Passivetestdata:............................................................................................................6 6.Radiationpattern............................................................................................................7 —3— 1.Performanceparameter Name Sexmassagemachine ModelType PCBAntenna FrenquencyRange2400-2500MHz SIZE / Impedance 50Ω VSWR <6.77 MaxGain -1.76dBi Manufacture ENVYHealthTechnology(Dongguan)Co.,Ltd. Address RM303,Bldg2,2DingwuZhenxingYiLu, DongkengTown,Dongguan,Guangdong, China523446 —4— 2.Appearance —5— 3.EUTsetupphotooffreespaceOTAtesting —6— 4.VSWRparameters Frequency (MHz) 240024502500 VSWR 6.775.163.43 5.Passivetestdata: Frequency(MHz)24002410242024302440245024602470248024902500 Gain(dBi)-3.88-3.25-3.31-4.28-3.55-3.32-3.61-3.34-3.05-3.31-1.76 Efficiency(%)13.1313.7213.0413.8213.8613.1613.5714.7116.0615.7217.39 — 7 — 6.Radiationpattern 2500.0MHzTotal(E1-XZ),Max=-4.39dBi 2500.0MHzTotal(E2-YZ),Max=-3.16dBi -- — 8 — Total(H-XY),Max=-4.24dBi,CirD=7.66 2500.0MHzH+V,Eff:17.4% — 9 — BackView --------------------------------------------------------End-------------------------------------------------------

Test Setup Photos

Page1of1 ReportNo.:FCS202608038 RE(30-1000MHz) RE(1000-18000MHz)

Contact Information

Applicant

Gao Lu(Quality Manager)
[email protected]Fax: 18025928401

Technical Contact

LOBOS IOWA INCHarley Li
[email protected]

4623 Bittercreek Dr Colorado Springs co 80922 Us · United States

Test Firm

Flux Compliance Service LaboratoryAndy Yue
[email protected]

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.40 GHz - 2.48 GHz-
Confidentiality
Long Term