2A6NY-YT-M002Outdoor Smart Outlet

ShenZhen YunTian Intelligence Control Technology CO., LTD.
Outdoor Smart Outlet - FCC ID 2A6NY-YT-M002 - ShenZhen YunTian Intelligence Control Technology CO., LTD.
Click to zoom

Application Details

Equipment Class
DTS - Digital Transmission System
Date of Grant
Jul 17, 2022
Application Purpose
Original Equipment
Date of Application
Jul 17, 2022
Equipment Note
Outdoor Smart Outlet
Frequency Range
2422.00000000 - 2452.00000000
Company
ShenZhen YunTian Intelligence Control Technology CO., LTD.
Country
China

Documents & Files

Select a file to view

Users Manual

↗

Cover Letter(s)

↗
↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗
↗
↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

• Scan the QR code to download: “Smart Life” app or search and download app directly from App store or google play. • Enter the register/login interface, input the phone No./ Email and password to login, or tap at the bottom of page connected to related authorization interface, input the phone NO./Email for getting verification code to register. • Note: Our app only supports 2.4GHz WI-FI networks. Part 2:Add plug FCC Statement This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: • Reorient or relocate the receiving antenna. • Increase the separation between the equipment and receiver. • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. • Consult the dealer or an experienced radio/TV technician for help. Caution: Any changes or modifications to this device not explicitly approved by manufacturer could void your authority to operate this equipment. This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. RF Exposure Information This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 20cm between the radiator and your body.

Cover Letter(s)

Sincerely, Name/Title: Changguo Wu/Manager Company: ShenZhen YunTian Intelligence Control Technology CO., LTD. Address: Room 706, Block A, GaoSheng Building, NO.18 Central Road, WanFeng Community, XinQiao Street,BaoAn District Shenzhen, China Phone: 0755-27800874 Fax: 0755-27800874 E-Mail: [email protected]

External Photos

Page 1 of 4 FCC ID: 2A6NY-YT-M002 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity External Photos of the EUT Fig. 1 Fig. 2 Page 2 of 4 FCC ID: 2A6NY-YT-M002 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Fig. 3 Fig. 4 Page 3 of 4 FCC ID: 2A6NY-YT-M002 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Fig. 5 Fig. 6 Page 4 of 4 FCC ID: 2A6NY-YT-M002 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Fig. 7 Fig. 8

ID Label/Location Info

Page 1 of 1 FCC ID: 2A6NY-YT-M002 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity LABEL AND LOCATION (Size: L2.5cm x 2.0cm) Label Location Outdoor Smart Outlet Model: YT-M002 FCC ID: 2A6NY-YT-M002

Internal Photos

Page 1 of 3 FCC ID: 2A6NY-YT-M002 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Internal Photos of the EUT Fig. 1 Fig. 2 Page 2 of 3 FCC ID: 2A6NY-YT-M002 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Fig. 3 Fig. 4 Page 3 of 3 FCC ID: 2A6NY-YT-M002 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Fig. 5 Fig. 6 Antenna

RF Exposure Info

Page 1 of 4 FCC ID: 2A6NY-YT-M002 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity FCC RF Exposure Evaluation 1. Product Information FCC ID 2A6NY-YT-M002 Product name Outdoor Smart Outlet Model number YT-M002 Power supply Input: AC 110V, 50/60Hz, 16A, 1760W Hardware version / Software version / FCC Operation frequency 2412~2462 MHz Channel Number 11 Channels for 20MHz bandwidth (2412~2462MHz) 7 Channels for 40MHz bandwidth (2422~2452MHz) Modulation Type IEEE 802.11b: DSSS (CCK, DQPSK, DBPSK) IEEE 802.11g: OFDM (64QAM, 16QAM, QPSK, BPSK) IEEE 802.11n: OFDM (64QAM, 16QAM,QPSK,BPSK) Antenna Type PCB Antenna Antenna Gain 0dBi(Max.) Exposure category General population/uncontrolled environment EUT Type Production Unit Device Type Mobile Devices Page 2 of 4 FCC ID: 2A6NY-YT-M002 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity 2. Evaluation Method Systems operating under the provisions of FCC 47 CFR section shall be operated in a manner that ensures that the public is not exposed to radio frequency energy level in excess of the Commission’s guidelines. In accordance with 47 CFR FCC Part 2 Subpart J, section 2.1091 this device has been defined as mobile device whereby a distance of 0.2m normally can be maintained between the user and the device, and below RF Permissible Exposure limit shall comply with. In accordance with KDB447498D01 for Simultaneous transmission MPE test exclusion applies when the sum of the MPE ratios for all simultaneous transmitting antennas incorporated in a host device, based on the calculated/estimated, numerically modelled or measured field strengths or power density, is ≤ 1.0. The MPE ratio of each antenna is determined at the minimum test separation distance required by the operating configurations and exposure conditions of the host device, according to the ratio of field strengths or power density to MPE limit, at the test frequency. Either the maximum peak or spatially averaged results from measurements or numerical simulations may be used to determine the MPE ratios. Spatial averaging does not apply when MPE is estimated using simple calculations based on far-field plane-wave equivalent conditions. The antenna installation and operating requirements for the host device must meet the minimum test separation distances required by all antennas, in both standalone and simultaneous transmission operations, to satisfy compliance. 3. Limit 3. 1 Refer Evaluation Method ANSI C95.1–1999: IEEE Standard for Safety Levels with Respect to Human Exposure to Radio Frequency Electromagnetic Fields, 3 kHz to 300 GHz. FCC KDB publication 447498 D01 General 1 RF Exposure Guidance v06: Mobile and Portable Devices RF Exposure Procedures and Equipment Authorization Policies. FCC CFR 47 part1 1.1310: Radiofrequency radiation exposure limits. FCC CFR 47 part2 2.1091: Radiofrequency radiation exposure evaluation: mobile devices 3. 2 Limit Limits for Maximum Permissible Exposure (MPE)/Controlled Exposure Frequency Range(MHz) Electric Field Strength(V/m) Magnetic Field Strength(A/m) Power Density (mW/cm²) Averaging Time (minute) Limits for Occupational/Controlled Exposure 0.3 – 3.0 3.0 – 30 30 – 300 300 – 1500 1500 – 100,000 614 1842/f 61.4 / / 1.63 4.89/f 0.163 / / (100) * (900/f 2 )* 1.0 f/300 5 6 6 6 6 6 Limits for Maximum Permissible Exposure (MPE)/Uncontrolled Exposure Frequency Range(MHz) Electric Field Strength(V/m) Magnetic Field Strength(A/m) Power Density (mW/cm²) Averaging Time (minute) Limits for Occupational/Controlled Exposure 0.3 – 3.0 3.0 – 30 30 – 300 300 – 1500 1500 – 100,000 614 824/f 27.5 / / 1.63 2.19/f 0.073 / / (100) * (180/f 2 )* 0.2 f/1500 1.0 30 30 30 30 30 F=frequency in MHz *=Plane-wave equivalent power density Page 3 of 4 FCC ID: 2A6NY-YT-M002 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity 4. MPE Calculation Method Predication of MPE limit at a given distance Equation from page 18 of OET Bulletin 65, Edition 97-01 S=PG/4πR² Where: S=power density P=power input to antenna G=power gain of the antenna in the direction of interest relative to an isotropic radiator R=distance to the center of radiation of the antenna 5. Antenna Information PCB Antenna can only use antennas certificated as follows provided by manufacturer; Internal Identification Antenna type and antenna number Operate frequency band Maximum antenna gain Note Antenna PCB Antenna 2400MHz-2500MHz 0dBi WIFI Antenna 6. Conducted Power <2.4G WIFI> Mode Channel Frequency(MHz) Max Conducted Power (dBm) IEEE 802.11b 1 2412 15.83 6 2437 14.97 11 2462 14.82 IEEE 802.11g 1 2412 14.07 6 2437 14.16 11 2462 13.02 IEEE 802.11n HT20 1 2412 13.15 6 2437 13.25 11 2462 13.04 IEEE 802.11n HT40 3 2422 12.64 6 2437 12.50 9 2452 12.57 Page 4 of 4 FCC ID: 2A6NY-YT-M002 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity 7. Manufacturing Tolerance <2.4G WIFI> 11B (Peak) Channel Channel 1 Channel 6 Channel 11 Target (dBm) 15.0 14.0 14.0 Tolerance ±(dB) 1.0 1.0 1.0 11G (Peak) Channel Channel 1 Channel 6 Channel 11 Target (dBm) 14.0 14.0 13.0 Tolerance ±(dB) 1.0 1.0 1.0 11N20SISO (Pea…

Text truncated - open the document above for the full version.

Test Report

Page 1 of 57 FCC ID: 2A6NY-YT-M002 Report No.: LCSA062422094EA Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Appendix A RF Test Data for 2.4GWIFI (Conducted Measurement) Product Name: Outdoor Smart Outlet Test Model: YT-M002 Environmental Conditions Temperature: 23.5  C Relative Humidity: 52.2% ATM Pressure: 100.0 kPa Test Engineer: Ling Zhu Supervised by: Li huan Page 2 of 57 FCC ID: 2A6NY-YT-M002 Report No.: LCSA062422094EA Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity A.1 DTS Bandwidth Test Result TestMode Antenna Channel DTS BW [MHz] FL[MHz] FH[MHz] Limit[MHz] Verdict 11B Ant1 2412 8.040 2408.000 2416.040 0.5 PASS 2437 8.080 2432.960 2441.040 0.5 PASS 2462 8.000 2458.000 2466.000 0.5 PASS 11G Ant1 2412 15.120 2404.440 2419.560 0.5 PASS 2437 15.720 2429.120 2444.840 0.5 PASS 2462 15.120 2454.440 2469.560 0.5 PASS 11N20SISO Ant1 2412 15.120 2404.440 2419.560 0.5 PASS 2437 16.280 2428.480 2444.760 0.5 PASS 2462 15.080 2454.440 2469.520 0.5 PASS 11N40SISO Ant1 2422 35.040 2404.480 2439.520 0.5 PASS 2437 35.680 2419.080 2454.760 0.5 PASS 2452 35.040 2434.480 2469.520 0.5 PASS Page 3 of 57 FCC ID: 2A6NY-YT-M002 Report No.: LCSA062422094EA Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Test Graphs 11B_Ant1_2412 11B_Ant1_2437 11B_Ant1_2462 Page 4 of 57 FCC ID: 2A6NY-YT-M002 Report No.: LCSA062422094EA Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity 11G_Ant1_2412 11G_Ant1_2437 Page 5 of 57 FCC ID: 2A6NY-YT-M002 Report No.: LCSA062422094EA Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity 11G_Ant1_2462 11N20SISO_Ant1_2412 Page 6 of 57 FCC ID: 2A6NY-YT-M002 Report No.: LCSA062422094EA Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity 11N20SISO_Ant1_2437 11N20SISO_Ant1_2462 Page 7 of 57 FCC ID: 2A6NY-YT-M002 Report No.: LCSA062422094EA Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity 11N40SISO_Ant1_2422 11N40SISO_Ant1_2437 Page 8 of 57 FCC ID: 2A6NY-YT-M002 Report No.: LCSA062422094EA Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity 11N40SISO_Ant1_2452 Page 9 of 57 FCC ID: 2A6NY-YT-M002 Report No.: LCSA062422094EA Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity A.2 Maximum conducted output power Test Result TestMode Antenna Channel Result[dBm] Limit[dBm] Verdict 11B Ant1 2412 15.83 ≤30.00 PASS 2437 14.97 ≤30.00 PASS 2462 14.82 ≤30.00 PASS 11G Ant1 2412 14.07 ≤30.00 PASS 2437 14.16 ≤30.00 PASS 2462 13.02 ≤30.00 PASS 11N20SISO Ant1 2412 13.15 ≤30.00 PASS 2437 13.25 ≤30.00 PASS 2462 13.04 ≤30.00 PASS 11N40SISO Ant1 2422 12.64 ≤30.00 PASS 2437 12.50 ≤30.00 PASS 2452 12.57 ≤30.00 PASS Page 10 of 57 FCC ID: 2A6NY-YT-M002 Report No.: LCSA062422094EA Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity A.3 Maximum power spectral density Test Result TestMode Antenna Channel Result[dBm/3kHz] Limit[dBm/3kHz] Verdict 11B Ant1 2412 -10.10 ≤8.00 PASS 2437 -10.68 ≤8.00 PASS 2462 -11.24 ≤8.00 PASS 11G Ant1 2412 -18.34 ≤8.00 PASS 2437 -19.43 ≤8.00 PASS 2462 -19.4 ≤8.00 PASS 11N20SISO Ant1 2412 -18.89 ≤8.00 PASS 2437 -19 ≤8.00 PASS 2462 -20.26 ≤8.00 PASS 11N40SISO Ant1 2422 -22.42 ≤8.00 PASS 2437 -23.98 ≤8.00 PASS 2452 -24.03 ≤8.00 PASS Page 11 of 57 FCC ID: 2A6NY-YT-M002 Report No.: LCSA062422094EA Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Test Graphs 11B_Ant1_2412 11B_Ant1_2437 11B_Ant1_2462 Page 12 of 57 FCC ID: 2A6NY-YT-M002 Report No.: LCSA062422094EA Shenzhen LCS Compliance Testing Laboratory Ltd…

Text truncated - open the document above for the full version.

Test Report

Page 34 of 57 FCC ID: 2A6NY-YT-M002 Report No.: LCSA062422094EA Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity 11N20SISO_Ant1_2437_1000~26500 11N20SISO_Ant1_2462_0~Reference Page 35 of 57 FCC ID: 2A6NY-YT-M002 Report No.: LCSA062422094EA Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity 11N20SISO_Ant1_2462_30~1000 11N20SISO_Ant1_2462_1000~26500 Page 36 of 57 FCC ID: 2A6NY-YT-M002 Report No.: LCSA062422094EA Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity 11N40SISO_Ant1_2422_0~Reference 11N40SISO_Ant1_2422_30~1000 Page 37 of 57 FCC ID: 2A6NY-YT-M002 Report No.: LCSA062422094EA Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity 11N40SISO_Ant1_2422_1000~26500 11N40SISO_Ant1_2437_0~Reference Page 38 of 57 FCC ID: 2A6NY-YT-M002 Report No.: LCSA062422094EA Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity 11N40SISO_Ant1_2437_30~1000 11N40SISO_Ant1_2437_1000~26500 Page 39 of 57 FCC ID: 2A6NY-YT-M002 Report No.: LCSA062422094EA Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity 11N40SISO_Ant1_2452_0~Reference 11N40SISO_Ant1_2452_30~1000 Page 40 of 57 FCC ID: 2A6NY-YT-M002 Report No.: LCSA062422094EA Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity 11N40SISO_Ant1_2452_1000~26500 Page 41 of 57 FCC ID: 2A6NY-YT-M002 Report No.: LCSA062422094EA Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity A.6 Duty Cycle Test Result TestMode Antenna Channel Transmission Duration [ms] Transmission Period [ms] Duty Cycle [%] Factor 1/T 11B Ant1 2412 8.38 8.42 99.52 0.02 0.12 2437 8.39 8.42 99.64 0.02 0.12 2462 8.39 8.42 99.64 0.02 0.12 11G Ant1 2412 1.39 1.44 96.53 0.15 0.72 2437 1.40 1.44 97.22 0.12 0.71 2462 1.39 1.44 96.53 0.15 0.72 11N20SISO Ant1 2412 1.30 1.34 97.01 0.13 0.77 2437 1.30 1.34 97.01 0.13 0.77 2462 1.30 1.34 97.01 0.13 0.77 11N40SISO Ant1 2422 0.65 0.70 92.86 0.32 1.54 2437 0.64 0.69 92.75 0.33 1.56 2452 0.64 0.69 92.75 0.33 1.56 Page 42 of 57 FCC ID: 2A6NY-YT-M002 Report No.: LCSA062422094EA Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Test Graphs 11B_Ant1_2412 11B_Ant1_2437 11B_Ant1_2462 Page 43 of 57 FCC ID: 2A6NY-YT-M002 Report No.: LCSA062422094EA Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity 11G_Ant1_2412 11G_Ant1_2437 Page 44 of 57 FCC ID: 2A6NY-YT-M002 Report No.: LCSA062422094EA Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity 11G_Ant1_2462 11N20SISO_Ant1_2412 Page 45 of 57 FCC ID: 2A6NY-YT-M002 Report No.: LCSA062422094EA Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity 11N20SISO_Ant1_2437 11N20SISO_Ant1_2462 Page 46 of 57 FCC ID: 2A6NY-YT-M002 Report No.: LCSA062422094EA Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity 11N40SISO_Ant1_2422 11N40SISO_Ant1_2437 Page 47 of 57 FCC ID: 2A6NY-YT-M002 Report No.: LCSA062422094EA Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-8…

Text truncated - open the document above for the full version.

Test Report

Page 1 of 36 FCC ID: 2A6NY-YT-M002 Report No.: LCSA062422094EA Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity FCC TEST REPORT For ShenZhen YunTian Intelligence Control Technology CO.,LTD. Outdoor Smart Outlet Test Model: YT-M002 Prepared for : ShenZhen YunTian Intelligence Control Technology CO.,LTD. Address : Room 706, Block A, GaoSheng Building, NO.18 Central Road,WanFeng Community, XinQiao Street. BaoAn District Shenzhen, China Prepared by : Shenzhen LCS Compliance Testing Laboratory Ltd. Address : 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel : (+86)755-82591330 Fax : (+86)755-82591332 Web : www.LCS-cert.com Mail : [email protected] Date of receipt of test sample : June 27, 2022 Number of tested samples : 2 Sample number : A062422094E-1, A062422094E-2 Serial number : Prototype Date of Test : June 27, 2022 ~ July 05, 2022 Date of Report : July 06, 2022 Page 2 of 36 FCC ID: 2A6NY-YT-M002 Report No.: LCSA062422094EA Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity FCC TEST REPORT FCC CFR 47 PART 15 C(15.247) Report Reference No. ................. : LCSA062422094EA Date of Issue ................................... : July 06, 2022 Testing Laboratory Name ............. : Shenzhen LCS Compliance Testing Laboratory Ltd. Address ........................................... : 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Testing Location/ Procedure ........... : Full application of Harmonised standards ■ Partial application of Harmonised standards □ Other standard testing method □ Applicant’s Name .......................... : ShenZhen YunTian Intelligence Control Technology CO.,LTD. Address ........................................... : Room 706, Block A, GaoSheng Building, NO.18 Central Road,WanFeng Community, XinQiao Street. BaoAn District Shenzhen, China Test Specification Standard .......................................... : FCC CFR 47 PART 15 C(15.247) Test Report Form No. ................... : LCSEMC-1.0 TRF Originator ................................ : Shenzhen LCS Compliance Testing Laboratory Ltd. Master TRF ..................................... : Dated 2011-03 Shenzhen LCS Compliance Testing Laboratory Ltd. All rights reserved. This publication may be reproduced in whole or in part for non-commercial purposes as long as the Shenzhen LCS Compliance Testing Laboratory Ltd. is acknowledged as copyright owner and source of the material. Shenzhen LCS Compliance Testing Laboratory Ltd. takes no responsibility for and will not assume liability for damages resulting from the reader's interpretation of the reproduced material due to its placement and context. EUT Description. ........................... : Outdoor Smart Outlet Trade Mark ...................................... : Cskyzk Test Model ...................................... : YT-M002 Ratings ............................................ : Input: AC 110V, 50/60Hz, 16A, 1760W Result ............................................ : Positive Compiled by: Supervised by: Approved by: Kay Hu/ Administrator Cary Luo/ Technique principal Gavin Liang/ Manager Page 3 of 36 FCC ID: 2A6NY-YT-M002 Report No.: LCSA062422094EA Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity FCC -- TEST REPORT EUT......................................... : Outdoor Smart Outlet Test Model............................... : YT-M002 Applicant............................... : ShenZhen YunTian Intelligence Control Technology CO.,LTD. Address.................................. : Room 706, Block A, GaoSheng Building, NO.18 Central Road,WanFeng Community, XinQiao Street. BaoAn District Shenzhen, China Telephone............................... : / Fax.......................................... : / Manufacturer........................ : ShenZhen YunTian Intelligence Control Technology CO.,LTD. Address................................... : Room 706, Block A, GaoSheng Building, NO.18 Central Road,WanFeng Community, XinQiao Street. BaoAn District Shenzhen, China Telephone............................... : / Fax.......................................... : / Factory................................... : ShenZhen YunTian Intelligence Control Technology CO.,LTD. Address................................... : Room 706, Block A, GaoSheng Building, NO.18 Central Road,WanFeng Community, XinQiao Street. BaoAn District Shenzhen, China Telephone............................... : / Fax.......................................... : / Test Result Positive The test report merely corresponds to the test sample. It is not permitted to copy extracts of these test result without the written permission of the test laboratory. Test Report No. : LCSA062422094EA July 06, 2022 Date of issue Page 4 of 36 FCC ID: 2A6NY-YT-M002 Report No.: LCSA062422094EA Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Revision History Report Version Issue Date Revision Content Revised By 000 July 06, 2022 Initial Issue --- Page 5 …

Text truncated - open the document above for the full version.

Test Setup Photos

Page 1 of 2 FCC ID: 2A6NY-YT-M002 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Test Setup Photos of the EUT Test Setup Photo(s) of Radiated Emissions Measurement Fig. 1 Fig. 2 Page 2 of 2 FCC ID: 2A6NY-YT-M002 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail:…

Text truncated - open the document above for the full version.

Contact Information

Applicant

Changguo Wu(Manager)
[email protected]0755-27800874Fax: 0755-27800874

Test Firm

Shenzhen LCS Compliance Testing Laboratory Ltd.Gavin Liang
[email protected]0755-82591330Fax: 0755-82591132

Technical Specifications

#Rule PartsFrequency RangePower Output
215C2.42 GHz - 2.45 GHz18.40 mW
Confidentiality
Long Term
Grant Notes
Output Power listed is peak conducted. This device supports 802.11b, 802.11g and 802.11n with a 20 MHz and 40 MHz bandwidth mode. RF exposure compliance is addressed for 1.1310 and 2.1091 MPE limits. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons. End Users must be provided with transmitter operation conditions for satisfying RF exposure compliance.