2A6Q6WISEWELLMODEL1Standalone / independent water purification system for tap water

WISEWELLWATER INC.
Standalone / independent water purification system for tap water - FCC ID 2A6Q6WISEWELLMODEL1 - WISEWELLWATER INC.
Click to zoom

Application Details

Equipment Class
DTS - Digital Transmission System
Date of Grant
Jun 21, 2022
Application Purpose
Original Equipment
Date of Application
Jun 21, 2022
Equipment Note
Standalone / independent water purification system for tap water
Frequency Range
2422.00000000 - 2452.00000000
Company
WISEWELLWATER INC.
Country
United States

Documents & Files

Select a file to view

Users Manual

↗

Cover Letter(s)

↗
↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

1 2 4 6 7 8 12 9 13 10 15 17 18 CONTENT Important Product Introduction Product Description Getting Started Maintenance Troubleshooting Setting up your Wisewell Changing the water Changing the filters Manually draining your Wisewell Cleaning your Wisewell Control panel Using your Wisewell 3 After moving it into place, please allow your device to stand for at least 24 hours before connecting it to power to avoid loss of function to the compressor. Model : MODEL 1 ~120V Please read this instruction manual carefully before operating the device. If you require assistance at any point, please contact us at [email protected] or visit our website www.wisewell.com Note: We reserve the right to make technological, functional, and surface modifications to improve the function and performance of our product. The product pictures, wording, and display in this manual are for reference only, and are subject to change. 4 POWER SUPPLY PRECAUTIONS 1. Make sure the power supply is greater than 10A, otherwise overheating or fire may occur. 2. Do not use multiple electrical appliances in the same outlet. 3. The device must be connected to a power outlet with a ground wire. 4. Never touch the power plug with wet hands. Always clean any dust or water stains from the power plug to reduce the risk of electric shock and fire. Please ensure that the plug is fully plugged into the outlet to avoid risk of electric leakage. 5. The power supply voltage must be consistent with the information on the product packaging. A voltage stabilizer is recommended for areas with unstable voltage. 6. In addition to causing safety hazards, improper connection can cause the warranty clause to become invalid. 7. To prevent fire, electric shock, or personal injury, do not immerse the power cord, outlet, or device in water. POWER CABLE 1. Please use the original power cord to avoid safety hazards. 2. If the device malfunctions, turn off the power, remove the water tank, and contact customer service. 3. To avoid electric shock, do not bend or crush the power cord underneath heavy objects, and avoid placing the cord where it can become a tripping hazard. If the device is not in use for an extended period of time, unplug the power cord and store it in a safe place. IMPORTANT Water source: Tap water Suitable water pressure: ≤ 0.3MPa. 5 SAFE ENVIRONMENT 1. Do not expose the device to temperatures below 32°F/0°C to prevent the pipe from leaking. 2. The ambient temperature requirement is from 39°F/4°C to 100°F/38°C. 3. Keep the device away from direct sunlight. Do not use it in places with low temperatures or flammable substances. To avoid damage to the device and water leaking, do not disassemble the device. 4. Before using Wisewell at elevations above 4921 feet/1500 meters, the hot water function should be disabled. DURING OPERATION 1. To prevent accidental burns, children and individuals with mobility impairments should not operate the device. 2. When using the hot water feature, use caution when removing the cup to avoid burns. 3. To keep the device in good condition, be sure to use the accessories and consumables provided by Wisewell. 4. While hot water is being dispensed, do not touch the water spout. AFTER USE 1. If the device will not be in use for an extended period of time, empty the water from the internal tank, and unplug the device from the power supply. (Please refer to the Maintenance section of this guide for more information on how to empty the tank). Filter and drain three tanks of water before use. 2. Do not carry or move the device by the extraction part. Use the side handles to move the device. OTHER NOTES 1. The device must be placed on a flat surface. Please drain the water from the internal tank before moving it. Do not tilt by more than 45 degrees when moving or operating the Wisewell. 2. Do not use with water that is microbiologically unsafe or of unknown quality without adequate disinfection before or after using the system. 3. This system conforms to NSF/ANSI 58 for the specific use cases listed in this user guide. This claim has been verified and substantiated by test data. 4. The use and installation of this system must comply with state and local laws and regulations. 6 PRODUCT INTRODUCTION Product Name: Wisewell Main bodyManual Filters Cleaning filters Water tank Pre-filter Power cord 7 PRODUCT DESCRIPTION 1. Control panel 2. LED lights 3. Adjustable water tray 4. Cleaning button 5. Filter reset 6. Filters 7. Drainage hole 8. Power Filter lights Select temperature Child lock Select temperature Get water WiFi Change water UV lamp Warning sign 1 2 3 4 6 7 8 5 8 GETTING STARTED Setting Up Your Wisewell Ensure all local, state, and federal laws and codes including health and safety guidelines are met when installing your Wisewell. POWER ON Connect the power cord to the power interface at the back of the device, and then insert the power plug into the outlet. SYNCING WITH THE APP 1. Grant the app permission to use WiFi and location access. 2. Enter your WiFi network and password into the app. 3. Put the purifier into Connection Mode by pressing and holding the left arrow and ‘Get Water’ button on the purifier’s touch panel until the WiFi icon blinks (it should take 3 seconds) 4. Tap ‘Connect’ in the app. This will transmit the WiFi credentials to the purifier while in connection mode. 5. The purifier will then try to connect to WiFi. - If it is successful, your mobile device will be labeled the owner of the Wisewell. - If it is not successful, the app will time out after a minute of waiting. FILL THE WATER TANK WITH TAP WATER Fill the water tank with tap water until the water level is between the MAX and MIN markings. PUT THE WATER TANK BACK 1. Return the water tank to the main body. If the locking tabs on the tank are not positioned on the device properly, re-adjust and lock it in place. The back of the water tank should now be locked onto the locking tabs of the device. 9 Using Your Wisewell 2. The purification…

Text truncated - open the document above for the full version.

Cover Letter(s)

Compliance Certification Services (Kunshan) Inc and Kidd Yang in Compliance Certification Services (Kunshan) Inc

External Photos

Compliance Certification Services (Kunshan) Inc. Shenzhen Branch Page: 1 of 4 External Photos for FYCR2204000087AT FCC ID: 2A6Q6WISEWELLMODEL1 Compliance Certification Services (Kunshan) Inc. Shenzhen Branch Page: 2 of 4 EUT Constructional Details (EUT Photos) Compliance Certification Services (Kunshan) Inc. Shenzhen Branch Page: 3 of 4 Compliance Certification Services (Kunshan) Inc. Shenzhen Branch Page: 4 of 4

Internal Photos

Compliance Certification Services (Kunshan) Inc. Shenzhen Branch Page: 1 of 18 Internal Photos for FYCR2204000087AT FCC ID: 2A6Q6WISEWELLMODEL1 Compliance Certification Services (Kunshan) Inc. Shenzhen Branch Page: 2 of 18 EUT Constructional Details (EUT Photos) Compliance Certification Services (Kunshan) Inc. Shenzhen Branch Page: 3 of 18 Compliance Certification Services (Kunshan) Inc. Shenzhen Branch Page: 4 of 18 Compliance Certification Services (Kunshan) Inc. Shenzhen Branch Page: 5 of 18 BT&WIFI ANT Compliance Certification Services (Kunshan) Inc. Shenzhen Branch Page: 6 of 18 Compliance Certification Services (Kunshan) Inc. Shenzhen Branch Page: 7 of 18 Compliance Certification Services (Kunshan) Inc. Shenzhen Branch Page: 8 of 18 Compliance Certification Services (Kunshan) Inc. Shenzhen Branch Page: 9 of 18 Compliance Certification Services (Kunshan) Inc. Shenzhen Branch Page: 10 of 18 Compliance Certification Services (Kunshan) Inc. Shenzhen Branch Page: 11 of 18 Compliance Certification Services (Kunshan) Inc. Shenzhen Branch Page: 12 of 18 Compliance Certification Services (Kunshan) Inc. Shenzhen Branch Page: 13 of 18 Compliance Certification Services (Kunshan) Inc. Shenzhen Branch Page: 14 of 18 Compliance Certification Services (Kunshan) Inc. Shenzhen Branch Page: 15 of 18 Compliance Certification Services (Kunshan) Inc. Shenzhen Branch Page: 16 of 18 Compliance Certification Services (Kunshan) Inc. Shenzhen Branch Page: 17 of 18 Compliance Certification Services (Kunshan) Inc. Shenzhen Branch Page: 18 of 18

RF Exposure Info

Compliance Certification Services (Kunshan) Inc. Shenzhen Branch Report No.: FYCR220400008703 Page: 1 of 10 Kidd Yang EMC Laboratory Manager 1 Cover Page RF Exposure Report Application No.: FYCR2204000087AT Applicant: Wisewellwater Inc Address of Applicant: Office 8010, 77 Sands St., Brooklyn, NY 11201, USA Manufacturer: Foshan Yuehuo Intelligence Technology Co.,Ltd Address of Manufacturer: No. 4, 3 rd Floor, Building E, Shengda Industry Zone, No. 2, XinXi 4th Road North, XiaShi village, LunJiao, ShunDe, Foshan, Guangdong, China. Factory: Foshan Yuehuo Intelligence Technology Co.,Ltd Address of Factory: No. 4, 3 rd Floor, Building E, Shengda Industry Zone, No. 2, XinXi 4th Road North, XiaShi village, LunJiao, ShunDe, Foshan, Guangdong, China. Equipment Under Test (EUT): EUT Name: Wisewell Model No.: Model 1 Trade Mark: FCC ID: 2A6Q6WISEWELLMODEL1 Standard(s) : FCC Rules 47 CFR §1.1307 FCC Rules 47 CFR §1.1310 FCC Rules 47 CFR §2.1091 KDB 447498 D04 interim General RF Exposure Guidance v01 Date of Receipt: 2022-04-19 Date of Test: 2022-04-22 to 2022-06-09 Date of Issue: 2022-06-13 Test Result: Pass* * In the configuration tested, the EUT complied with the standards specified above. Compliance Certification Services (Kunshan) Inc. Shenzhen Branch Report No.: FYCR220400008703 Page: 2 of 10 Revision Record Version Chapter Date Modifier Remark 01 2022-06-13 Original Authorized for issue by: Tree Zhan/Project Engineer Winkey Wang/Reviewer Compliance Certification Services (Kunshan) Inc. Shenzhen Branch Report No.: FYCR220400008703 Page: 3 of 10 2 Contents Page 1 COVER PAGE .................................................................................................................................... 1 2 CONTENTS ........................................................................................................................................ 3 3 GENERAL INFORMATION ................................................................................................................ 4 3.1 GENERAL DESCRIPTION OF E.U.T. ................................................................................................ 4 3.2 DETAILS OF E.U.T. ....................................................................................................................... 4 3.3 SEPARATION DISTANCE ................................................................................................................ 5 3.4 TEST LOCATION ............................................................................................................................ 5 3.5 TEST FACILITY .............................................................................................................................. 5 4 FCC RADIOFREQUENCY RADIATION EXPOSURE LIMITS .......................................................... 6 4.1 BLANKET 1 MW BLANKET EXEMPTION ........................................................................................... 6 4.2 MPE-BASED EXEMPTION .............................................................................................................. 6 4.3 SAR-BASED EXEMPTION ............................................................................................................... 7 5 MEASUREMENT AND CALCULATION .......................................................................................... 10 5.1 MAXIMUM TRANSMIT POWER ....................................................................................................... 10 5.2 RF EXPOSURE CALCULATION ...................................................................................................... 10 Compliance Certification Services (Kunshan) Inc. Shenzhen Branch Report No.: FYCR220400008703 Page: 4 of 10 3 General Information 3.1 General Description of E.U.T. Product Type: Portable device Mobile device Fixed device 3.2 Details of E.U.T. Power Supply: Input 120V~, 60Hz, 1500W Cable(s): AC input cable: 100cm, unshielded For BLE: Operation Frequency: 2402MHz to 2480MHz Bluetooth Version: V5.0 LE Modulation Type: GFSK Data Rate: 1M/bit Number of Channels: 40 Channel Spacing: 2MHz Antenna Type: PCB Antenna Antenna Gain: 3.42dBi For 2.4G: Operation Frequency: 802.11b/g/n(HT20): 2412MHz to 2462MHz; 802.11n(HT40): 2422MHz to 2452MHz Modulation Type: 802.11b: DSSS (CCK, DQPSK, DBPSK);802.11g/n: OFDM (64QAM, 16QAM, QPSK, BPSK) Number of Channels: 802.11b/g/n(HT20):11; 802.11n(HT40):7 Channel Spacing: 5MHz Antenna Type: PCB Antenna Antenna Gain: 3.42dBi Compliance Certification Services (Kunshan) Inc. Shenzhen Branch Report No.: FYCR220400008703 Page: 5 of 10 3.3 Separation Distance Minimum test separation distance: 20cm Remark: This minimum test separation distance is determined by the smallest distance from the antenna and radiating structures or outer surface of the device, according to the host form factor, exposure conditions and platform requirements, to any part of the body or extremity of a user or bystander. 3.4 Test Location All tests were performed at: Compliance Certification Services(Kunshan)Inc. Shenzhen branch. Fuyong lab. Xinlong TechnoPark,Fengtang Road, Fuyong Subdistrict, Bao’an, Shenzhen, China Tel: +86 755 8866 3988 Fax: +86 755 2671 0594 No tests were sub-contracted. 3.5 Test Facility The test facility is recognized, certified, or accredited by the following organizations: • A2LA (Certificate No. 6606.01) Compliance Certification Services(Kunshan)Inc. Shenzhen branch is accredited by the American Association for Laboratory Accreditation(A2LA). Certificate No. 6606.01. • FCC –Designation Number: CN1322 Compliance Certification Services(Kunshan)Inc. Shenzhen branch has been recognized as an accredited testing laboratory. Designation Number: CN1322. Test Firm Registration Number: 718073 • Innovation, Science and Economic Development Canada Compliance Certification Services(Kunshan)Inc. Shenzhen branch has been recognized by ISED as an accredited testing laboratory. CAB identifier: CN0129. IC#: 28189. Compliance Certi…

Text truncated - open the document above for the full version.

Test Report

Compliance Certification Services (Kunshan) Inc. Shenzhen Branch Report No.: FYCR220400008701 Page: 1 of 57 Kidd Yang EMC Laboratory Manager TEST REPORT Application No.: FYCR2204000087AT Applicant: Wisewellwater Inc Address of Applicant: Office 8010, 77 Sands St., Brooklyn, NY 11201, USA Manufacturer: Foshan Yuehuo Intelligence Technology Co.,Ltd Address of Manufacturer: No. 4, 3 rd Floor, Building E, Shengda Industry Zone, No. 2, XinXi 4th Road North, XiaShi village, LunJiao, ShunDe, Foshan, Guangdong, China. Factory: Foshan Yuehuo Intelligence Technology Co.,Ltd Address of Factory: No. 4, 3 rd Floor, Building E, Shengda Industry Zone, No. 2, XinXi 4th Road North, XiaShi village, LunJiao, ShunDe, Foshan, Guangdong, China. Equipment Under Test (EUT): EUT Name: Standalone / independent water purification system for tap water Model No.: Model 1 Trade Mark: FCC ID: 2A6Q6WISEWELLMODEL1 Standard(s) : 47 CFR Part 15, Subpart C 15.247 Date of Receipt: 2022-04-19 Date of Test: 2022-04-22 to 2022-06-09 Date of Issue: 2022-06-13 Test Result: Pass* * In the configuration tested, the EUT complied with the standards specified above. Compliance Certification Services (Kunshan) Inc. Shenzhen Branch Report No.: FYCR220400008701 Page: 2 of 57 Revision Record Version Chapter Date Modifier Remark 01 2022-06-13 Original Authorized for issue by: Tree Zhan/Project Engineer Winkey Wang/Reviewer Compliance Certification Services (Kunshan) Inc. Shenzhen Branch Report No.: FYCR220400008701 Page: 3 of 57 2 Test Summary Radio Spectrum Technical Requirement Item Standard Method Requirement Result Antenna Requirement 47 CFR Part 15, Subpart C 15.247 N/A 47 CFR Part 15, Subpart C 15.203 & 15.247(b)(4) Pass Radio Spectrum Matter Part Item Standard Method Requirement Result Conducted Emissions at AC Power Line (150kHz-30MHz) 47 CFR Part 15, Subpart C 15.247 ANSI C63.10 (2013) Section 6.2 47 CFR Part 15, Subpart C 15.207 Pass Conducted Peak Output Power ANSI C63.10 (2013) Section 11.9.1 47 CFR Part 15, Subpart C 15.247(b)(3) Pass Minimum 6dB Bandwidth ANSI C63.10 (2013) Section 11.8.1 47 CFR Part 15, Subpart C 15.247a(2) Pass Power Spectrum Density ANSI C63.10 (2013) Section 11.10.2 47 CFR Part 15, Subpart C 15.247(e) Pass Conducted Band Edges Measurement ANSI C63.10 (2013) Section 11.13.3.2 47 CFR Part 15, Subpart C 15.247(d) Pass Conducted Spurious Emissions ANSI C63.10 (2013) Section 11.11 47 CFR Part 15, Subpart C 15.247(d) Pass Radiated Emissions which fall in the restricted bands ANSI C63.10 (2013) Section 6.10.5 47 CFR Part 15, Subpart C 15.205 & 15.209 Pass Radiated Spurious Emissions Below 1GHz ANSI C63.10 (2013) Section 6.4,6.5 47 CFR Part 15, Subpart C 15.205 & 15.209 Pass Radiated Spurious Emissions Above 1GHz ANSI C63.10 (2013) Section 6.6 47 CFR Part 15, Subpart C 15.205 & 15.209 Pass Compliance Certification Services (Kunshan) Inc. Shenzhen Branch Report No.: FYCR220400008701 Page: 4 of 57 3 Contents Page 1 COVER PAGE ............................................................................................................................................ 1 2 TEST SUMMARY ....................................................................................................................................... 3 3 CONTENTS ................................................................................................................................................ 4 4 GENERAL INFORMATION ........................................................................................................................ 6 4.1 DETAILS OF E.U.T. ............................................................................................................................... 6 4.2 DESCRIPTION OF SUPPORT UNITS ......................................................................................................... 6 4.3 MEASUREMENT UNCERTAINTY .............................................................................................................. 6 4.4 TEST LOCATION .................................................................................................................................... 7 4.5 TEST FACILITY ...................................................................................................................................... 7 4.6 DEVIATION FROM STANDARDS ............................................................................................................... 7 4.7 ABNORMALITIES FROM STANDARD CONDITIONS ..................................................................................... 7 5 EQUIPMENT LIST ...................................................................................................................................... 8 6 RADIO SPECTRUM TECHNICAL REQUIREMENT ............................................................................... 12 6.1 ANTENNA REQUIREMENT .................................................................................................................... 12 6.1.1 Test Requirement: ....................................................................................................................... 12 6.1.2 Conclusion ................................................................................................................................... 12 7 RADIO SPECTRUM MATTER TEST RESULTS ..................................................................................... 13 7.1 CONDUCTED EMISSIONS AT AC POWER LINE (150KHZ-30MHZ) ........................................................... 13 7.1.1 E.U.T. Operation .......................................................................................................................... 13 7.1.2 Test Mode Description ................................................................................................................. 13 7.1.3 Test Setup Diagram ..................................................................................................................... 14 7.1.4 Measurement Procedure …

Text truncated - open the document above for the full version.

Test Setup Photos

Compliance Certification Services (Kunshan) Inc. Shenzhen Branch Page: 1 of 3 Appendix Photographs of Test Setup for FYCR2204000087AT FCC ID: 2A6Q6WISEWELLMODEL1 Compliance Certification Services (Kunshan) Inc. Shenzhen Branch Page: 2 of 3 Test Setup Photos Radiated Emissions which fall in the restricted bands Radiated Spurious Emissions Below 1GHz Compliance Certification Services (Kunshan) Inc. Shenzhen Branch Page: 3 of 3 Radiated Spurious Emissions Above 1GHz Conducted Emissions at Mains Terminals (150kHz-30MHz)

Contact Information

Applicant

Sebastien Wakim
[email protected]2695288410Fax: N/A

Technical Contact

Compliance Certification Services (Kunshan) IncKidd Yang
[email protected]+8675525326619

Fuyong Lab Xinlong Techno Park Fengtang Road · Shenzhen · China

Non-Technical Contact

Compliance Certification Services (Kunshan) IncKidd Yang
[email protected]+8675525326619

Test Firm

Compliance Certification Services (Kunshan) IncLina Ye
[email protected]8613798526121

Technical Specifications

#Rule PartsFrequency RangePower Output
315C2.42 GHz - 2.45 GHz25.60 mW
Confidentiality
Long Term
Grant Notes
Output Power listed is conducted. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons. Co-location of this module with other transmitters that operate simultaneously are required to be evaluated using the FCC multi-transmitter procedures. End-Users must be provided with transmitter operation conditions for satisfying RF exposure compliance. This device supports 20MHz and 40MHz bandwidth modes.