Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
Shenzhen Romoss Technology Co., Ltd. Letter of Authorization Company:Shenzhen Romoss Technology C o., Ltd. Address: Room 1601, BLOCK B, Building 7, Shenzhen International Innovation Valley, Nanshan, Shenzhen Product Name:Portable Power Station Model Number:RS1000 Trade mark: ROMOSS FCC Identifier: 2A6QM-RS1000 We authorize MiCOM Labs Inc, 575 Boulder Court, Pleasanton, California 94566, USA, to act on our behalf on all matters concerning the above named equipment. Any individual within MiCOM Labs is authorized to act on our behalf and take action on the application. We declare that MiCOM Labs Inc, 575 Boulder Court, Pleasanton, California 94566, USA, is allowed to forward all information related to the approval project to the Federal Communication Commission and to discuss any issues concerning the approval application. Any and all acts carried out by MiCOM Labs on our behalf shall have the same effect as acts of our own. Name: Leo Qin Signature of applicant: Date:10 .2 1 .2022 Leo Qin
ShenzhenRomossTechnologyCo.,Ltd. Company:ShenzhenRomossTechnologyCo.,Ltd. Address:Room1601,BLOCKB,Building7,ShenzhenInternationalInnovation Valley,Nanshan,Shenzhen TheEUTdoescomplywithitem5.2ofKDB680106D01v03asfollowstable RequirementsofKDB680106D01Yes/NoDescription (1)Powertransferfrequencyislessthan 1MHz Yes (2)Outputpowerfromeachprimarycoil islessthanorequalto15watts. Yes (3)Thesystemmayconsistofmorethan onesourceprimarycoils,chargingoneor moreclients.If morethanoneprimarycoilispresent,the coilpairsmaybepoweredonatthesame time The EUT frequency range is: 110kHz- 205kHz The output power of wireless charging is 10W(Max) . EUThasonlyonecoi NO l (4)Clientdeviceisplaceddirectlyin contactwiththetransmitter. YesEUTcanbedirectlycharged (5)Mobileexposureconditionsonly (portableexposureconditionsarenot coveredbythisexclusion). YesEUTisamobiledevice (6)TheaggregateH-fieldstrengths anywhereatorbeyond15cm surroundingthedevice,and20cm awayfromthesurfacefromallcoilsthat bydesigncansimultaneouslytransmit, andwhilethose coilsaresimultaneouslyenergized,are demonstratedtobelessthan50%ofthe applicableMPE limit. YesFulfilrequirements Name:LeoQin Signatureofapplicant Date:10.21.2022 :
FCCID:2A6QM-RS1000
label locaton label size:119.65*117.65mm
FCCID:2A6QM-RS1000
TRFNo.FCCRFExposure_R4 Add:WestSideof1/F.,BuildingC,ZoneA,FuyuanNewFactory,JiujiuIndustrialPark,Minzhu,Shatou,Shajing, Bao'anDistrict,Shenzhen,Guangdong,China Tel:+(86)0755-29852678Fax:+(86)0755-29852397E-mail:[email protected]:www.gdksign.com Page1of7 RFExposureEvaluation FCCID:2A6QM-RS1000 MeasuringStandard FCCPart1(1.1310)andPart2(2.1091) KDB680106D01RFExposureWirelessChargingBaseAppv03 TestConfiguration ThetestdistanceofPositionEonthefrontsideis20cm,thetestdistanceofPositionA,B,C,Dis15cmusing theequipmentlistabovefordeterminingcompliancewiththeMPErequirementsofFCCPart1.1310. TheRFpowerdensitywasmeasuredatUndermaximumloadtest. ThetestdistanceofPositionEonthefrontsideis20cm,thetestdistanceofPositionA,B,C,Dis15cm,the fieldprobeswerepositionedatthelocationwherethereismaximumfieldstrength.ThemaximumE-fieldand H-fieldisreportedbelow. Thisdeviceusesawirelesschargingcircuitforpowertransferoperatingatthefrequencyof110.1KHz -205kHz.Thus,the300kHzlimitswereused:E-fieldLimit=614(V/m);H-fieldlimit=1.63(A/m). TESTSetup TRFNo.FCCRFExposure_R4 Add:WestSideof1/F.,BuildingC,ZoneA,FuyuanNewFactory,JiujiuIndustrialPark,Minzhu,Shatou,Shajing, Bao'anDistrict,Shenzhen,Guangdong,China Tel:+(86)0755-29852678Fax:+(86)0755-29852397E-mail:[email protected]:www.gdksign.com Page2of7 TESTLimits MeasuringDeviceandTestEquipment DescriptionManufacturerModelS/N Cal.Until ProbeFHP (1Hz-400KHz) NardaSafetyTest SolutionsGmbH EHP-50F J-0015 Nov11,2022 AdapterN/A YHY-24006 250 N/AN/A PHONE1HUAWEIP40N/AN/A TRFNo.FCCRFExposure_R4 Add:WestSideof1/F.,BuildingC,ZoneA,FuyuanNewFactory,JiujiuIndustrialPark,Minzhu,Shatou,Shajing, Bao'anDistrict,Shenzhen,Guangdong,China Tel:+(86)0755-29852678Fax:+(86)0755-29852397E-mail:[email protected]:www.gdksign.com Page3of7 TESTMODE MODETESTMODEDESCRIPTION 1wirelesschargingmode(Fullload) 2wirelesschargingmode(Halfload) 3wirelesschargingmode(Nullload) Note: 1.TheMode1wastheworstcaseandonlythedataoftheworstcaserecordinthisreport. TESTRESULT PassedNotApplicable TRFNo.FCCRFExposure_R4 Add:WestSideof1/F.,BuildingC,ZoneA,FuyuanNewFactory,JiujiuIndustrialPark,Minzhu,Shatou,Shajing, Bao'anDistrict,Shenzhen,Guangdong,China Tel:+(86)0755-29852678Fax:+(86)0755-29852397E-mail:[email protected]:www.gdksign.com Page4of7 EUTPortablePowerStationModelName.:RS1000 Pressure:1010hPaTestDate:2022-10-31 TestVoltage:Output:10W(Max)TestMode:Mode1(worsecase) E-FieldStrengthat15cmsurroundingtheEUTand20cmabovethetopsurfaceoftheEUT EUTSide Frequency Range (KHz) Probe A (V/m) Probe B (V/m) Probe C (V/m) Probe D (V/m) Probe E (V/m) Limits (V/m) 50%Limit (V/m) Fullload110~2050.860.870.890.880.97 614307 Halfload110~2050.830.830.840.830.96 Nullload110~2050.760.730.750.730.94 H-FieldStrengthat15cmsurroundingtheEUTand20cmabovethetopsurfaceoftheEUT EUTSide Frequency Range (KHz) Probe A (A/m) Probe B (A/m) Probe C (A/m) Probe D (A/m) Probe E (A/m) Limits (A/m) 50%Limit (A/m) Fullload110~2050.450.460.480.490.78 1.630.815Halfload110~2050.430.430.460.450.67 Nullload110~2050.420.410.430.430.63 Remark:ThedevicemeetsthemobileRFexposurelimitata15cmseparationdistanceasspecified in§2.1091oftheFCCRules. Note:OnlytheMode1worstcasemodesisrecordedinthereport. TRFNo.FCCRFExposure_R4 Add:WestSideof1/F.,BuildingC,ZoneA,FuyuanNewFactory,JiujiuIndustrialPark,Minzhu,Shatou,Shajing, Bao'anDistrict,Shenzhen,Guangdong,China Tel:+(86)0755-29852678Fax:+(86)0755-29852397E-mail:[email protected]:www.gdksign.com Page5of7 PHOTOGRAPHSOFTESTSETUP PositionE PositionA TRFNo.FCCRFExposure_R4 Add:WestSideof1/F.,BuildingC,ZoneA,FuyuanNewFactory,JiujiuIndustrialPark,Minzhu,Shatou,Shajing, Bao'anDistrict,Shenzhen,Guangdong,China Tel:+(86)0755-29852678Fax:+(86)0755-29852397E-mail:[email protected]:www.gdksign.com Page6of7 PositionB PositionC TRFNo.FCCRFExposure_R4 Add:WestSideof1/F.,BuildingC,ZoneA,FuyuanNewFactory,JiujiuIndustrialPark,Minzhu,Shatou,Shajing, Bao'anDistrict,Shenzhen,Guangdong,China Tel:+(86)0755-29852678Fax:+(86)0755-29852397E-mail:[email protected]:www.gdksign.com Page7of7 PositionD **********************THEEND**********************
FCC ID:2A6QM-RS1000 ANTinformation(MM) A 45±0.5 B 43±0.5 C 19±0.5 D 5±0.5 E 5±1 S 16±1
ReportNo.:KS2210S4535E TRFNo.FCCPart18_R2 Add:WestSideof1/F.,BuildingC,ZoneA,FuyuanNewFactory,JiujiuIndustrialPark,Minzhu,Shatou, Shajing,Bao'anDistrict,Shenzhen,Guangdong,China Tel:+(86)0755-29852678Fax:+(86)0755-29852397E-mail:[email protected]:www.gdksign.com Page 1 of 32 TESTREPORT ReportNo.. ......................................... :KS2210S4535E FCCID. ................................................. :2A6QM-RS1000 Applicant..............................................:ShenzhenRomossTechnologyCo.,Ltd. Address. ................................................ :Room1601,BLOCKB,Building7,ShenzhenInternationalInnovation Valley,Nanshan,ShenzhenChina Manufacturer........................................: ShenzhenVacoNewMaterialTechnologyCo.,Ltd Address.................................................: Room40109,building1,HuahanScienceandTechnologyIndustrial Park,19QiyunWestRoad,HepingCommunity,PingshanStreet,Ping shandistrict,ShenzhenCity ProductName.....................................: PortablePowerStation TradeMark............................................: ROMOSS Model/Typereference.........................: RS1000 Standard..............................................:FCCRulesandRegulationsPart18 Dateofreceiptoftestsample............: October20,2022 Dateoftesting. ..................................... :October20,2022~October31,2022 Dateofissue ......................................... :October31,2022 TestResult..........................................:Pass Preparedby: (PrintedName+Signature) PaiZheng Approvedby: (PrintedName+Signature) SkyDong TestingLaboratoryName................:KSIGN(Guangdong)TestingCo.,Ltd. Address.................................................: WestSideof1/F.,BuildingC,ZoneA,FuyuanNewFactory,Jiujiu IndustrialPark,Minzhu,Shatou,Shajing,Bao'anDistrict,Shenzhen, Guangdong,China Thistestreportmaybeduplicatedcompletelyforlegalusewiththeapprovaloftheapplicant.Itshouldnot bereproducedexceptinfull,withoutthewrittenapprovalofourlaboratory.Theclientshouldnotuseitto claimproductendorsementbyKSIGN.Thetestresultsinthereportonlyapplytothetestedsample.The testreportshallbeinvalidwithoutallthesignaturesoftestingengineers,reviewerandapprover. AnyobjectionsmustberaisedtoKSIGNwithin15dayssincethedatewhenthereportisreceived.Itwillnot betakenintoconsiderationbeyondthislimit.Thetestreportmerelycorrespondtothetestsample. ReportNo.:KS2210S4535E TRFNo.FCCPart18_R2 Add:WestSideof1/F.,BuildingC,ZoneA,FuyuanNewFactory,JiujiuIndustrialPark,Minzhu,Shatou, Shajing,Bao'anDistrict,Shenzhen,Guangdong,China Tel:+(86)0755-29852678Fax:+(86)0755-29852397E-mail:[email protected]:www.gdksign.com Page 2 of 32 Contents 1TESTSUMMARY..............................................................................................................................................3 1.1TestStandards................................................................................................................................................3 1.2ReportVersion................................................................................................................................................3 1.3Addressofthetestlaboratory.........................................................................................................................4 1.4TestFacility.....................................................................................................................................................4 1.5Environmentalconditions................................................................................................................................4 1.6Summaryofmeasurementresults..................................................................................................................5 1.7Statementofthemeasurementuncertainty...................................................................................................5 2GENERALINFORMATION...............................................................................................................................6 2.1ProductDescription........................................................................................................................................6 2.2Descriptionofthetestmode...........................................................................................................................7 2.3SpecialAccessories........................................................................................................................................7 2.4Modifications...................................................................................................................................................7 2.5EquipmentsUsedduringtheTest..................................................................................................................8 3TESTCONDITIONSANDRESULTS...............................................................................................................9 3.1ACPowerConductedEmission....................................................................................................................9 3.2RadiatedEmission........................................................................................................................................12 3.3AntennaRequirement...................................................................................................................................20 4.TESTSETUPPHOTOSOFTHEEUT...........................................................................................................21 5.PHOTOSOFTHEEUT..................................................................................................................................23 ReportNo.:KS2210S4535E TRFNo.FCCPart18_R2 Add:WestSideof1/F.,BuildingC,ZoneA,FuyuanNewFactory,JiujiuIndustrialPark,Minzhu,Shatou, Shajing,Bao'anDistrict,Shenzhen,Guangdong,China Tel:+(86)0755-29852678Fax:+(86)0755-29852397E-mail:[email protected]:www.gdksign.com Page 3 of 32 1TESTSUMMARY 1…
Text truncated - open the document above for the full version.
FCCID:2A6QM-RS1000 RadiatedMeasurement(Below30MHz) RadiatedMeasurement(Above30MHz) ConductedEmission
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 18 | 0.11 MHz - 0.205 MHz | - |
Portable Power Station
Equipment Class
DCD - Part 15 Low Power Transmitter Below 1705 kHzFast Charging Power Bank
Equipment Class
DCD - Part 15 Low Power Transmitter Below 1705 kHzPortable Power Station
Equipment Class
DCD - Part 15 Low Power Transmitter Below 1705 kHz
Wireless Power Bank
Equipment Class
DCD - Part 15 Low Power Transmitter Below 1705 kHz
Wireless Power Bank
Equipment Class
DCD - Part 15 Low Power Transmitter Below 1705 kHz