Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
01030502040607 Portable Power Station Cleaning and Maintenance Product Maintenance Cleaning Product Transportation and Storage Disposal of Batteries Common Questions 1. Can I use the product while charging? 2. Is the charger heating normal during charging? 3. Why does the fan start sometimes? 5. Why can't the charging equipment be used within the rated range of the product? 6. Can I take the outdoor power supply on board? 4. Why does the product shut down automatically during use? Our outdoor power supply supports charging while using, but it is not recommended to use it during charging, for it will affect battery life. Heating is normal for the charger during charging. Our standard charger meets the requirements of the national safety standard. Please use with peace of mind. Outdoor power supply is equipped with high temperature protection function and the working of the built-in fan is conducive to the heat dissipation of outdoor power supply, thus avoiding high temperature. Therefore, the fan will start automatically when the temperature reaches a certain set value during use, and there will be a mild sound. When the outdoor power supply stops or only uses the low-power equipment, the output will automatically shut down after the time set by the system so as to avoid unnecessary energy consumption when the user forgets to shut down. * The battery level is lower than 20%! Please charge it. * The starting power of some charging devices will be greater than the peak power of the outdoor power supply, or the actual operating power is higher than the rated output power of the outdoor power supply! Therefore, it is recommended to choose a power supply with a higher power. No, the outdoor power supply belongs to the lithium battery product. According to the regulations of airlines, passengers are prohibited to take lithium battery products with a capacity greater than 100Wh on board. Troubleshooting of Main Faults Charging failure No product output Sudden interruption of output SymptomTroubleshootingSolution Check that the product, adapter and mains supply are properly connected Good contact, adapter indicator light off The charging indicator light is on but charging fails Rule out whether it's a contact problem The adapter is faulty; contact the after-sales service personnel Contact the after-sales service personnel Connecting lines of equipment and product not inserted in place Check whether the corresponding output switch is turned on Low battery level of product The product is still not usable after the factors above are ruled out Contact the after-sales service personnel Check and debug the device connection carefully Open the corresponding output switch and the display screen will display the output power Charge the product The power of the electronic equipment in use exceeds the rated power of the product The output power is too low and the product automatically shuts down after several hours of use Automatic protection against overcurrent, high/low temperature and other conditions cuts off the output Please purchase the product with the corresponding power and contact after-sales service personnel for more information The automatic shutdown function is set. Please turn on the main switch to start the product. The product is equipped with 7 protection functions. If the output is shut down due to overcurrent or overvoltage, please press the button again to start it when the product is restored to normal. User Manual Caution Guideline for Safe Use Charging Modes Outdoor power supply Outdoor power supply AC adapterOutdoor power supply Read the User Manual carefully and familiarize yourself with the product functions before performing operations. We do not assume any legal liability for serious injury caused to yourself or others, or damage to products or property caused by failing to follow the instructions. Do not use parts that are not provided or recommended, and be sure to strictly follow the instructions to install and use the product, or else you are not eligible to enjoy our free after-sales services. Method 1: Charging through AC adapter Method 2: Charging through solar panel Method 3: Charging through car charger (12V) Automotive power plug (cigarette lighter port) ★ Batteries may be in sleep mode due to long-term transportati on and storage; please charge the product with the adapter; the battery will be activated after charging for 10 minutes. ★ Before use for the first time, please fully charge the produc t to avoid product failure due to low battery. Operation Manual 1.The AC/ USB/ DC output switch can be normally turned on only when the power switch is turned on; if you need to charge the electronic device through AC/ DC/ ECO, please turn on the corresponding switch (USB/DC output is controlled by the DC switch). Once the switch is turned on, the LCD lights up and displays the corresponding data. 2.Press the main power switch to turn on or off the outdoor power supply. 3.ECO mode: When the main power switch is turned on, the ECO switch will automatically turn on, and the ECO mode will start. After no-load running for a period of time, it will automatically shut down (please consult customer service personnel for details). You can press the ECO button (the indicator is off) to disable the auto sleep function. 4.LED switch: Press the LED light button to turn on the flashlight; press the button again to turn on the LED light, and press and hold the button for 3-5 seconds to enable SOS mode. 5.When the power switch is turned on, the wireless charging function is available. Product Function Introduction DC Output buttonLED light button ECO button B: DC 。 AC Output button D : AC 。 ECO 。 C: E: A: Power button AC adapter Button Introduction Packing List Car-mount USB (Car charger port) A: Battery indication: The percentage and the number of battery bars show the remaining power. The power icon will flash and jump when charging, and stop flashing when fully charged. B: Battery time:…
Text truncated - open the document above for the full version.
ShenzhenRomossTechnologyCo.,Ltd. OfficeofEngineeringTechnology FederalCommunicationsCommission 7435OaklandMillsRoad Columbia,MD21046 USA Subject;RequestforConfidentialit Date: 2022-09-14 y FCC ID: 2A6QM-RS500 To Whom It May Concern, Pursuant to the provisions of the Commission’s rules Title 47 Sections §0.457 and §0.459, we are requesting the Commission to withhold the following attachment(s) as confidential documents from public disclosure indefinitely. These documents contain detailed system and equipment descriptions and are considered as proprietary information in operation of the equipment. The public disclosure of these documents might be harmful to our company and would give competitors an unfair advantage in the market. SchematicDiagram BlockDiagram PartsList OperationalDescription Tune-upProcedure Itisourunderstandingthatallmeasurementtestreports,FCCIDlabelformatand correspondenceduringthecertificationreviewprocesscannotbegrantedasconfidential documentsandthisinformationwillbeavailableforpublicreviewoncethegrantofequipment authorizationisissued. Sincerely, Signature: Name:LeoQin Title:Manager
Shenzhen Romoss Technology Co., Ltd. Letter of Authorization Company:Shenzhen Romoss Technology C o., Ltd. Address: Room 1601, BLOCK B, Building 7, Shenzhen International Innovation Valley, Nanshan, Shenzhen Product Name:Portable Power Station Model Number:RS500 Trade mark: ROMOSS FCC Identifier: We authorize MiCOM Labs Inc, 575 Boulder Court, Pleasanton, California 94566, USA, to act on our behalf on all matters concerning the above named equipment. Any individual within MiCOM Labs is authorized to act on our behalf and take action on the application. We declare that MiCOM Labs Inc, 575 Boulder Court, Pleasanton, California 94566, USA, is allowed to forward all information related to the approval project to the Federal Communication Commission and to discuss any issues concerning the approval application. Any and all acts carried out by MiCOM Labs 2A6QM-RS500 on our behalf shall have the same effect as acts of our own. Name: Leo Qin Date: 09.14.2022 Signature of applicant: Leo Qin
ShenzhenRomossTechnologyCo.,Ltd. Company:ShenzhenRomossTechnologyCo.,Ltd. Address:Room1601,BLOCKB,Building7,ShenzhenInternationalInnovation Valley,Nanshan,Shenzhen TheEUTdoescomplywithitem5.2ofKDB680106D01v03asfollowstable RequirementsofKDB680106D01Yes/NoDescription (1)Powertransferfrequencyislessthan 1MHz Yes TheEUTfrequencyrangeis:110kHz- 205kHz (2)Outputpowerfromeachprimarycoil islessthanorequalto15watts. YesTheoutputpowerislessthan15W (3)Thesystemmayconsistofmorethan onesourceprimarycoils,chargingoneor moreclients.If morethanoneprimarycoilispresent,the coilpairsmaybepoweredonatthesame time. YesEUThasonlyonecoil (4)Clientdeviceisplaceddirectlyin contactwiththetransmitter. YesEUTcanbedirectlycharged (5)Mobileexposureconditionsonly (portableexposureconditionsarenot coveredbythisexclusion). YesEUTisamobiledevice (6)TheaggregateH-fieldstrengths anywhereatorbeyond15cm surroundingthedevice,and20cm awayfromthesurfacefromallcoilsthat bydesigncansimultaneouslytransmit, andwhilethose coilsaresimultaneouslyenergized,are demonstratedtobelessthan50%ofthe applicableMPE limit. YesFulfilrequirements Name:LeoQinDate:09.14.2022 Signatureofapplicant:
FCCID:2A6QM-RS500
FCC ID:2A6QM-RS500 Label location
FCCID:2A6QM-RS500
KSIGN(Guangdong)TestingCo,Ltd. FirstFloorWestSide,BuildingC,ZoneA,FuyuanNewFactory,JiujiuIndustrialPark,MinzhuVillage, ShatouCommunity,ShajingStreet,Bao'anDistrict,ShenzhenCity,GuangdongProvince,P.R.China Tel.:+(86)755-29852678Fax:+(86)755-29852397E-mail:[email protected]:www.gdksign.com KSIGN(Guangdong)TestingCo.,Ltd. RFExposureEvaluation FCCID:2A6QM-RS500 MeasuringStandard FCCPart1(1.1310)andPart2(2.1091) KDB680106D01RFExposureWirelessChargingBaseAppv03 TestConfiguration ThetestdistanceofPositionEonthefrontsideis20cm,thetestdistanceofPositionA,B,C,Dis15cmusing theequipmentlistabovefordeterminingcompliancewiththeMPErequirementsofFCCPart1.1310. TheRFpowerdensitywasmeasuredatUndermaximumloadtest. ThetestdistanceofPositionEonthefrontsideis20cm,thetestdistanceofPositionA,B,C,Dis15cm,the fieldprobeswerepositionedatthelocationwherethereismaximumfieldstrength.ThemaximumE-fieldand H-fieldisreportedbelow. Thisdeviceusesawirelesschargingcircuitforpowertransferoperatingatthefrequencyof110.1KHz -205kHz.Thus,the300kHzlimitswereused:E-fieldLimit=614(V/m);H-fieldlimit=1.63(A/m). TESTSetup KSIGN(Guangdong)TestingCo,Ltd. FirstFloorWestSide,BuildingC,ZoneA,FuyuanNewFactory,JiujiuIndustrialPark,MinzhuVillage, ShatouCommunity,ShajingStreet,Bao'anDistrict,ShenzhenCity,GuangdongProvince,P.R.China Tel.:+(86)755-29852678Fax:+(86)755-29852397E-mail:[email protected]:www.gdksign.com KSIGN(Guangdong)TestingCo.,Ltd. TESTLimits MeasuringDeviceandTestEquipment DescriptionManufacturerModelS/N Cal.Until ProbeFHP(1Hz-400KHz) NardaSafetyTest SolutionsGmbH EHP-50F J-0015 Nov11,2022 AdapterN/AN/AN/AN/A PHONEHUAWEIP40N/AN/A TESTMODE KSIGN(Guangdong)TestingCo,Ltd. FirstFloorWestSide,BuildingC,ZoneA,FuyuanNewFactory,JiujiuIndustrialPark,MinzhuVillage, ShatouCommunity,ShajingStreet,Bao'anDistrict,ShenzhenCity,GuangdongProvince,P.R.China Tel.:+(86)755-29852678Fax:+(86)755-29852397E-mail:[email protected]:www.gdksign.com KSIGN(Guangdong)TestingCo.,Ltd. MODETESTMODEDESCRIPTION 1wirelesschargingmode(Fullload) 2wirelesschargingmode(Halfload) 3wirelesschargingmode(Nullload) Note: 1.TheMode1wastheworstcaseandonlythedataoftheworstcaserecordinthisreport. TESTRESULT PassedNotApplicable KSIGN(Guangdong)TestingCo,Ltd. FirstFloorWestSide,BuildingC,ZoneA,FuyuanNewFactory,JiujiuIndustrialPark,MinzhuVillage, ShatouCommunity,ShajingStreet,Bao'anDistrict,ShenzhenCity,GuangdongProvince,P.R.China Tel.:+(86)755-29852678Fax:+(86)755-29852397E-mail:[email protected]:www.gdksign.com KSIGN(Guangdong)TestingCo.,Ltd. EUT PortablePowerStation ModelName.: RS500 Pressure:1010hPaTestDate:2022-09-20 TestVoltage:Output:10W(Max)TestMode:Mode1(worsecase) E-FieldStrengthat15cmsurroundingtheEUTand20cmabovethetopsurfaceoftheEUT EUT Side Frequency Range (KHz) Probe A (V/m) Probe B (V/m) Probe C (V/m) Probe D (V/m) Probe E (V/m) Limits (V/m) Full load 110~2050.670.660.460.470.58 614 Half load 110~2050.640.640.440.430.54 Null load 110~2050.580.570.420.410.53 H-FieldStrengthat15cmsurroundingtheEUTand20cmabovethetopsurfaceoftheEUT EUT Side Frequency Range (KHz) Probe A (A/m) Probe B (A/m) Probe C (A/m) Probe D (A/m) Probe E (A/m) Limits (A/m) Full load 110~2050.230.220.180.180.13 1.63 Half load 110~2050.180.160.170.160.10 Null load 110~2050.190.180.140.150.11 Remark:ThedevicemeetsthemobileRFexposurelimitata15cmseparationdistanceasspecified in§2.1091oftheFCCRules. Note:OnlytheMode1worstcasemodesisrecordedinthereport. KSIGN(Guangdong)TestingCo,Ltd. FirstFloorWestSide,BuildingC,ZoneA,FuyuanNewFactory,JiujiuIndustrialPark,MinzhuVillage, ShatouCommunity,ShajingStreet,Bao'anDistrict,ShenzhenCity,GuangdongProvince,P.R.China Tel.:+(86)755-29852678Fax:+(86)755-29852397E-mail:[email protected]:www.gdksign.com KSIGN(Guangdong)TestingCo.,Ltd. PHOTOGRAPHSOFTESTSETUP PositionE PositionA KSIGN(Guangdong)TestingCo,Ltd. FirstFloorWestSide,BuildingC,ZoneA,FuyuanNewFactory,JiujiuIndustrialPark,MinzhuVillage, ShatouCommunity,ShajingStreet,Bao'anDistrict,ShenzhenCity,GuangdongProvince,P.R.China Tel.:+(86)755-29852678Fax:+(86)755-29852397E-mail:[email protected]:www.gdksign.com KSIGN(Guangdong)TestingCo.,Ltd. PositionB PositionC KSIGN(Guangdong)TestingCo,Ltd. FirstFloorWestSide,BuildingC,ZoneA,FuyuanNewFactory,JiujiuIndustrialPark,MinzhuVillage, ShatouCommunity,ShajingStreet,Bao'anDistrict,ShenzhenCity,GuangdongProvince,P.R.China Tel.:+(86)755-29852678Fax:+(86)755-29852397E-mail:[email protected]:www.gdksign.com KSIGN(Guangdong)TestingCo.,Ltd. PositionD **********************THEEND**********************
ANTSize:ANTdiameter:4.8cm
ReportNo.:KS2209S4030E TRFNo.FCCPart18_R2 Add:WestSideof1/F.,BuildingC,ZoneA,FuyuanNewFactory,JiujiuIndustrialPark,Minzhu,Shatou, Shajing,Bao'anDistrict,Shenzhen,Guangdong,China Tel:+(86)0755-29852678Fax:+(86)0755-29852397E-mail:[email protected]:www.gdksign.com Page 1 of 31 TESTREPORT ReportNo..........................................:KS2209S4030E FCCID...............................................:2A6QM-RS500 Applicant............................................:ShenzhenRomossTechnologyCoLtd. Address..............................................: Room1601,BLOCKB,Building7,ShenzhenInternational InnovationValley,Nanshan,Shenzhen,China Manufacturer......................................:ShenzhenVacoNewMaterialTechnologyCoLtd Address..............................................: C203,No3Plant,KejiRoad,ZhukengCommunity,LongtianStreet, PingshanDistrict,ShenzhenCity,GuangdongProvince,P.R.China ProductName.................................:PortablePowerStation TradeMark........................................:ROMOSS Model/Typereference........................:RS500 Standard...........................................:FCCRulesandRegulationsPart18 DateofReceipt..................................:September7,2022 DateofTestDate...............................:September7,2022~September20,2022 Dateofissue......................................:September22,2022 Testresult........................................:Pass Preparedby: (PrintedName+Signature) OuldZheng Approvedby: (PrintedName+Signature) SkyDong TestingLaboratoryName...............:KSIGN(Guangdong)TestingCo.,Ltd. Addres...............................................: WestSideof1/F.,BuildingC,ZoneA,FuyuanNewFactory,Jiujiu IndustrialPark,Minzhu,Shatou,Shajing,Bao'anDistrict, Shenzhen,Guangdong,China Thistestreportmaybeduplicatedcompletelyforlegalusewiththeapprovaloftheapplicant.Itshouldnot bereproducedexceptinfull,withoutthewrittenapprovalofourlaboratory.Theclientshouldnotuseitto claimproductendorsementbyKSIGN.Thetestresultsinthereportonlyapplytothetestedsample.The testreportshallbeinvalidwithoutallthesignaturesoftestingengineers,reviewerandapprover. AnyobjectionsmustberaisedtoKSIGNwithin15dayssincethedatewhenthereportisreceived.Itwillnot betakenintoconsiderationbeyondthislimit.Thetestreportmerelycorrespondtothetestsample. ReportNo.:KS2209S4030E TRFNo.FCCPart18_R2 Add:WestSideof1/F.,BuildingC,ZoneA,FuyuanNewFactory,JiujiuIndustrialPark,Minzhu,Shatou, Shajing,Bao'anDistrict,Shenzhen,Guangdong,China Tel:+(86)0755-29852678Fax:+(86)0755-29852397E-mail:[email protected]:www.gdksign.com Page 2 of 31 Contents 1TESTSUMMARY..............................................................................................................................................3 1.1TestStandards................................................................................................................................................3 1.2ReportVersion................................................................................................................................................3 1.3Addressofthetestlaboratory.........................................................................................................................4 1.4TestFacility.....................................................................................................................................................4 1.5Environmentalconditions................................................................................................................................4 1.6Summaryofmeasurementresults..................................................................................................................5 1.7Statementofthemeasurementuncertainty...................................................................................................5 2GENERALINFORMATION...............................................................................................................................6 2.1ProductDescription........................................................................................................................................6 2.2Descriptionofthetestmode...........................................................................................................................7 2.3SpecialAccessories........................................................................................................................................7 2.4Modifications...................................................................................................................................................7 2.5EquipmentsUsedduringtheTest..................................................................................................................8 3TESTCONDITIONSANDRESULTS...............................................................................................................9 3.1ACPowerConductedEmission....................................................................................................................9 3.2RadiatedEmission........................................................................................................................................12 3.3AntennaRequirement...................................................................................................................................20 4.TESTSETUPPHOTOSOFTHEEUT...........................................................................................................21 5.PHOTOSOFTHEEUT..................................................................................................................................23 ReportNo.:KS2209S4030E TRFNo.FCCPart18_R2 Add:WestSideof1/F.,BuildingC,ZoneA,FuyuanNewFactory,JiujiuIndustrialPark,Minzhu,Shatou, Shajing,Bao'anDistrict,Shenzhen,Guangdong,China Tel:+(86)0755-29852678Fax:+(86)0755-29852397E-mail:[email protected]:www.gdksign.com Page 3 of 31 1TESTSUMMARY 1.1TestStandards Thetestswereperformedaccordingtofollowingstandards: F…
Text truncated - open the document above for the full version.
FCCID:2A6QM-RS500 RadiatedMeasurement(Below30MHz) RadiatedMeasurement(Above30MHz) ConductedEmission
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 18 | 0.11 MHz - 0.205 MHz | - |
Portable Power Station
Equipment Class
DCD - Part 15 Low Power Transmitter Below 1705 kHzFast Charging Power Bank
Equipment Class
DCD - Part 15 Low Power Transmitter Below 1705 kHzPortable Power Station
Equipment Class
DCD - Part 15 Low Power Transmitter Below 1705 kHz
Wireless Power Bank
Equipment Class
DCD - Part 15 Low Power Transmitter Below 1705 kHz
Wireless Power Bank
Equipment Class
DCD - Part 15 Low Power Transmitter Below 1705 kHz