Application Details

Equipment Class
DTS - Digital Transmission System
Date of Grant
Jun 01, 2022
Application Purpose
Original Equipment
Date of Application
Jun 01, 2022
Equipment Note
CookPerfect Wireless Docking station
Frequency Range
2412.00000000 - 2462.00000000
Company
CookPerfect ApS
Country
Denmark

Documents & Files

Select a file to view

Users Manual

Cover Letter(s)

↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗

Test Setup Photos

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Cover Letter(s)

C5266091_X8_Ed.1 1/1 LetterofAuthorization Company:CookPerfectApS Address:OstreAlle6,DK-9530StovringDenmark ProductName:CookPerfectWirelessDockingstation ModelNumber:CP-W-200 FCCIdentifier:2A6ST-CP-W-200 WeauthorizeLGAITechnologicalCenterS.A.,RondadelaFontdelCarme,s/n, 08193Bellaterra,Spain,toactonourbehalfonallmattersconcerningthe abovenamedequipment. AnyindividualwithinLGAITechnologicalCenterS.A.isauthorizedtoactonour behalfandtakeactionontheapplication. WedeclarethatauthorizeLGAITechnologicalCenterS.A.,RondadelaFontdel Carme,s/n,08193Bellaterra,Spain,isallowedtoforwardallinformation relatedtotheapprovalprojecttotheFederalCommunicationCommissionand todiscussanyissuesconcerningtheapprovalapplication.Anyandallacts carriedoutbyLGAITechnologicalCenterS.A.onourbehalfshallhavethe sameeffectasactsofourown. Name:MartinKlosterDate:2022-5-26 Title:ManagingDirector,Co-founder Signatureofapplicant:

Cover Letter(s)

C5266091_X10_Ed.2 1/1 CookPerfectApS OfficeofEngineeringTechnology FederalCommunicationsCommission 7435OaklandMillsRoad Columbia,MD21046 Date:2022-5-26 Subject:RequestforConfidentiality FCCID:2A6ST-CP-W-200 ToWhomItMayConcern, PursuanttotheprovisionsofSections0.457and0.459ofCommission'srules (47CFR0.457,0.459),wearerequestingtheCommissiontowithholdthefollowing attachment(s)asconfidentialdocumentfrompublicdisclosure. ExhibitsLong-Term Confidentiality Short-Term Confidentiality NOTE2 IDLabel/LocationNoNo AttestationStatementNoNo ExternalPhotosNo ☐ BlockDiagram ☒☐ Schematics ☒☐ TestReportNoNo TestSetupPhotosNo ☐ User’sManual ☐ NOTE 1 ☒ InternalPhotos ☐ NOTE 1 ☒ PartsList/TuneUp ☐☐ RFExposureInfoNoNo OperationalDescription ☒☐ CoverLetter(s)NoNo SDRSoftware/SecurityInfo ☐ No NOTE1:Long-TermConfidentialitymaybepermittedunderspecialconditions(SeeII.LONG-TERMCONFIDENTIALITY,Section3of KDB726920,uselastinforce) NOTE2:Short-TermConfidentialitycanberequestedforamaximumof180daysfromthedateofthegrant. Abovementioneddocumentcontainsdetailedsystemandequipmentdescriptionare consideredasproprietaryinformationinoperationoftheequipment.Thepublic disclosureofabovedocumentsmightbeharmfultoourcompanyandwouldgive competitoranunfairadvantageinthemarket. Incaseofshort-termConfidentiality,theapplicantrequeststheexhibitsselected abovearewithheldfrompublicviewforaperiodof__180____daysfromthedateof theGrantofEquipmentAuthorizationandpriortomarketing. Itisourunderstandingthatallmeasurementtestreports,FCCIDlabelformatand correspondentduringcertificationreviewprocesscannotbegrantedasconfidential documentsandthoseinformationwillbeavailableforpublicreviewoncethegrantof equipmentauthorizationisissued. C5266091_X10_Ed.2 1/1 Sincerely, Signature: Name:MartinKloster Title:ManagingDirector,Co-founder

External Photos

Annex A External Photos Report No.: HK2205091903-1E/2E Page 1 of 4 Report No.: HK2205091903-1E/2E Page 2 of 4 Report No.: HK2205091903-1E/2E Page 3 of 4 Report No.: HK2205091903-1E/2E Page 4 of 4

Internal Photos

Annex B Internal Photo Report No.: HK2205091903-1E/2E Page 1 of 3 Report No.: HK2205091903-1E/2E Page 2 of 3 WiFi Antenna BT Antenna Report No.: HK2205091903-1E/2E Page 3 of 3

RF Exposure Info

MPE ESTIMATION FCC ID: 2A6ST-CP-W-200 1. Limit for General Population/ Uncontrolled Exposures Frequency Power density (mW/ cm 2 ) Averaging time(minutes) 300MHz----1.5GHz F/1500 30 1.5GHz---100GHz 1.0 30 2. Estimation Result Mode Max PK Output power(dBm) Tune Up Power(dBm) Max Tune Up power(mW) Antenna Gain(dBi) Antenna Gain (linear) MPE (mW/cm²) Te s t Results WIFI 18.76 18±1(19) 79.43 1 1.2589 0.01990 PASS BLE 0.22 0±1(1) 1.26 1 1.2589 0.00032 PASS Note: Note: The estimation distance is 20cm Note: PK Output power= conducted power. Conducted power see the test report HK2205091903-1/-2E. Gantenna gain=1dBi 3. Simultaneous transmission MPE Considerations According to KDB447498 :For mobile exposure host platform to qualify for simultaneous transmission MPE test exclusion, all transmitters and antennas in the host must be either evaluated for MPE compliance, by measurement or computational modeling, or qualify for the standalone MPE test exclusion in section 7.1. Simultaneous transmission MPE test exclusion applies when the sum of the MPE ratios for all simultaneous transmitting antennas incorporated in a host device, based on the calculated/estimated, numerically modeled or measured field strengths or power density, is ≤ 1.0. This means that: ∑ of MPE ratios ≤ 1.0 BLE and WIFI Simultaneous evaluation: 0.01990+0.00032=0.02022<1 4. Conclusion This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. -------The End-------

Test Report

Page 1 of 60 Report No.: HK2205091903-1E FCC TEST REPORT Test report On Behalf of CookPerfect ApS For CookPerfect Wireless Docking station Model No.: CP-W-200 FCC ID: 2A6ST-CP-W-200 Prepared For : CookPerfect ApS Ostre Alle 6, DK-9530 Stovring, Denmark Prepared By : Shenzhen HUAK Testing Technology Co., Ltd. 1-2/F., Building B2, Junfeng Zhongcheng Zhizao Innovation Park, Heping, Fuhai Street, Bao’an District, Shenzhen, Guangdong, China Date of Test: May. 10, 2022 ~ May. 17, 2022 Date of Report: May. 17, 2022 Report Number: HK2205091903-1E Applican Address Manufa c Address Product Trade M a Product n Model an Standard This pub the She n source o and will reprodu c Date of T Date (s) o Date of Is Te s t R e s nt’s name .. .................. cture's Nam .................. descripti o ark: name .......... nd/or type re ds .............. lication ma y nzhen HUA f the mater not assu m ced materia Test ............ of performa ssue .......... ult .............. Te s Te c Aut TES ................ : ................ : me ............ : ................ : on ................... : eference : ................ : y be reprod AK Testing ial. Shenzh me liability l due to its p .................. ance of tests .................. .................. sting Engine chnical Man thorized Sig ST RESU CookPerf Ostre Alle Suzhou Q No.168 Y Jiangsu 2 CookPer f CookPerf CP-W-20 FCC Rul e ANSI C63 duced in wh Te c h n o l o gy en HUAK T for damag placement a .............. : s ............. : .............. : .............. : eer : nager : gnatory : Page 2 of ULT CER fect ApS e 6, DK-953 Qiyang Elec Yinzang Roa 215105, Chi fect fect Wireles 0 es and Regu 3.10: 2013 hole or in pa y Co., Ltd. Testing Tech ges resultin and context May. 10, 20 May. 17, 20 Pass 60 RTIFICAT 30 Stovring, ctromechani ad, Linhu To ina ss Docking s ulations Par art for non-c is acknowl hnology Co ng from the t. 022 ~ May. 1 022 (Gary Qi a (Eden H u (Jason Zho Report N TION Denmark ical Techno own, Wuzho station rt 15 Subpar commercial ledged as ., Ltd. take s e reader's 17, 2022 an) u) ou) No.: HK2205 logy Co.,LT ong District, rt C Section purposes a copyright o s no respon interpretati 091903-1E TD Suzhou, n 15.247 as long as owner and nsibility for on of the Page 3 of 60 Report No.: HK2205091903-1E TABLE OF CONTENTS 1. TEST RESULT SUMMARY ........................................................................ 5 1.1. TEST PROCEDURES AND RESULTS ............................................................................................... 5 1.2. INFORMATION OF THE TEST LABORATORY ................................................................................ 5 1.3. MEASUREMENT UNCERTAINTY ..................................................................................................... 6 2. EUT DESCRIPTION ................................................................................... 7 2.1. GENERAL DESCRIPTION OF EUT ................................................................................................... 7 2.2. CARRIER FREQUENCY OF CHANNELS .......................................................................................... 8 2.3. OPERATION OF EUT DURING TESTING .......................................................................................... 8 2.4. DESCRIPTION OF TEST SETUP ....................................................................................................... 9 3. GENERA INFORMATION ........................................................................ 10 3.1. TEST ENVIRONMENT AND MODE ................................................................................................. 10 3.2. DESCRIPTION OF SUPPORT UNITS .............................................................................................. 11 4. TEST RESULTS AND MEASUREMENT DATA ...................................... 12 4.1. CONDUCTED EMISSION ................................................................................................................. 12 4.2. TEST RESULT .................................................................................................................................. 14 4.3. MAXIMUM CONDUCTED OUTPUT POWER ................................................................................... 16 4.4. EMISSION BANDWIDTH .................................................................................................................. 18 4.5. POWER SPECTRAL DENSITY ........................................................................................................ 23 4.6. CONDUCTED BAND EDGE AND SPURIOUS EMISSION MEASUREMENT ................................. 28 4.7. RADIATED SPURIOUS EMISSION MEASUREMENT .................................................................... 36 5. ANTENNA REQUIREMENT ..................................................................... 57 6. PHOTOGRAPH OF TEST ........................................................................ 58 7. PHOTOS OF THE EUT ............................................................................ 60 Page 4 of 60 Report No.: HK2205091903-1E ** Modified History ** Revision Description Issued Data Remark Revision 1.0 Initial Test Report Release May. 17, 2022 Jason Zhou Page 5 of 60 Report No.: HK2205091903-1E 1. TEST RESULT SUMMARY 1.1. TEST PROCEDURES AND RESULTS Requirement CFR 47 Section Result Antenna requirement §15.203/§15.247(b)(4) PASS AC Power Line Conducted Emission §15.207 PASS Conducted Peak Output Power §15.247(b)(3) PASS 6dB Emission Bandwidth §15.247(a)(2) PASS Power Spectral Density §15.247(e) PASS Band Edge §15.247(d) PASS Spurious Emission §15.205/§15.209 PASS Note: 1. PASS: Test item meets the requirement. 2. Fail: Test item does not meet the requirement. 3. N/A: Test case does not apply to the test object. 4. The test result judgment is decided by the limit of test standard. 1.2. INFORMATION OF THE TEST LABORATORY Shenzhen HUAK Testing Technology Co., Ltd. Add.: 1-2/F., Building B2, Junfeng Zhongcheng …

Text truncated - open the document above for the full version.

Contact Information

Applicant

Martin Kloster(Managing Director, Co-founder)
[email protected]+45 3035 4077Fax: +45 3035 4077

Technical Contact

Shenzhen HUAK Testing Technology Co., LtdJason Zhou
[email protected]0755-23029901

Shenzhen · China

Test Firm

Shenzhen HUAK Testing Technology Co., Ltd.Jason Zhou
[email protected]86-755-23029901

Technical Specifications

#Rule PartsFrequency RangePower Output
215C2.41 GHz - 2.46 GHz75.20 mW
Confidentiality
Long Term
Grant Notes
Output power listed is conducted. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20cm from all persons. End-users must be provided with operating procedures for satisfying RF exposure compliance.