FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Netsens Srl/
  3. 2A6TE-MN014XEO

2A6TE-MN014XEOIoT wireless data detection unit

Netsens Srl
IoT wireless data detection unit - FCC ID 2A6TE-MN014XEO - Netsens Srl
Click to zoom

Application Details

Equipment Class
DTS - Digital Transmission System
Date of Grant
Oct 25, 2023
Application Purpose
Original Equipment
Date of Application
Oct 25, 2023
Equipment Note
IoT wireless data detection unit
Frequency Range
903.00000000 - 914.20000000
Company
Netsens Srl
Country
Italy

Documents & Files

Select a file to view

Users Manual

↗

Attestation Statements

↗
↗

Cover Letter(s)

↗
↗
↗

External Photos

↗
↗
↗

ID Label/Location Info

↗
↗

Internal Photos

↗
↗
↗

Parts List/Tune Up Info

↗

RF Exposure Info

↗

Test Report

↗
↗
↗

Test Setup Photos

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

0-33 Manuale Utente / User Guide Manuale Utente / User Guide 1-33 Manuale Utente / User Guide Pagina Lasciata Intenzionalmente Vuota / This Page Intentionally Left Blank 2-33 Manuale Utente / User Guide PRODOTTO DA / MANUFACTURED BY : Netsens s.r.l. Via delle Cantine 97 – 50041 Calenzano (Firenze) - Italy Phone : (+39) 0553437042 Fax: (+39) 0553416085 Website: www.netsens.it CONTATTI / CONTACTS : Informazioni Generali / General Information : [email protected] Supporto Tecnico / Technical Support : [email protected] Revisione / Revision : 1.4 – Maggio / May 2023 3-33 Manuale Utente / User Guide Pagina Lasciata Intenzionalmente Vuota / This Page Intentionally Left Blank 4-33 Manuale Utente / User Guide Sommario Introduzione / Introduction ................................................................................................................... 6 Use restrictions and warning - FCC ...................................................................................................... 7 RF Radiation Exposure statement ........................................................................................................ 7 Caratteristiche Tecniche / Technical Specifications ...................................................................... 9 Stima Consumi Energetici / Evaluation of Energy Consumption ........................................ 11 Connessione Unità Ricevitore wireless / Wireless receiver Unit Wiring .............................. 13 Dispositivi di Interfaccia Operatore/ Operator Devices Handling .......................................... 15 Funzionalità Schermate Display / LCD Display Functions ..................................................... 17 Schermate Misure Acquisite / Display Measures Values ........................................................................ 19 Configurazione di Sistema / System Configuration ................................................................................. 21 Interfaccia USB / USB Interface ......................................................................................................... 23 Operazioni preliminari all’accensione / Before Activation ........................................................ 25 Accensione del sistema / Power On .............................................................................................. 25 Guida all’Installazione Unità Wireless / Wireless Unit Installation Guide .......................... 27 Risoluzione Problemi / Troubleshooting .......................................................................................... 29 Garanzia / Warranty ................................................................................................................................ 30 Configurazione Software Unità / Unit Software Configuration............................................... 31 Collegamenti Elettrici / Electrical Wiring ........................................................................................ 32 5-33 Manuale Utente / User Guide Pagina Lasciata Intenzionalmente Vuota / This Page Intentionally Left Blank 6-33 Manuale Utente / User Guide Introduzione / Introduction Il sistema netsens IoT è costituito da una stazione base e ricevente, ed una serie di unità wireless remote installate in campo, indipendenti l’una dalle altre. Le unità wireless IoT sono alimentate da una batteria interna di lunga durata, che garantisce lunghi intervalli di manutenzione e sostituzione. Ciascuna stazione base dispone di un ricevitore IoT che acquisisce i dati delle unità in campo e consente la trasmissione verso il sistema di acquisizione centrale (cloud LiveData ® o altro). The Netsens IoT system consists of a base and receiving station, and a series of remote wireless units installed in the field, independent of each other. The wireless units are powered by a long-life internal battery, which guarantees long maintenance and replacement intervals. Each base station has an IoT receiver that acquires the data of the units in the field and allows the transmission to the central acquisition system (LiveData® cloud system or other). 7-33 Manuale Utente / User Guide Use restrictions and warning - FCC 1.Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. 2.Device MN-0146-EO, MN-0147-EO: FCC ID: 2A6TE-MN014XEO 3.This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. 4. This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: —Reorient or relocate the receiving antenna. —Increase the separation between the equipment and receiver. —Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. —Consult the dealer or an experienced radio/TV technician for help. RF Radiation Exposure statement This product complies with FCC and ISED radiation exposure limits set forth for an uncontrolled environment. The antenna should be installed and operated with minimum distance of 20 cm between the radiator and your body. 8-33 Manua…

Text truncated - open the document above for the full version.

Attestation Statements

1 Netsens s.r.l. – via delle Cantine 97 Calenzano (FI) – Italy Tel +39 055 3437042 – Fax +39 055 3416085 Cod.Fisc / P.IVA / CCIAA: 05475380480 – REA: FI-549634 RAEE IT09020000005793 - Cap. Soc. € 200.000,00 i.v. Azienda con Sistema Qualità Certificato ISO 9001:2015 e Sistema di Gestione Ambientale Certificato ISO 14001:2015 Covered Equipment Certification Attestation Letter DATE 06/05/2023 Nemko North America, Inc. 303 River Road Ottawa K1V 1H2 Canada ATTN.: Reviewing Engineer FCC ID: 2A6TE-MN014XEO Netsens srl (“the applicant”) certifies that the equipment for which authorization is sought is not “covered” equipment prohibited from receiving an equipment authorization pursuant to section 2.903 of the FCC rules. Note: If the equipment for which the applicant seeks authorization is produced by any of the entities identified on the current Covered List, the applicant should include an explanation on why the equipment is not “covered” equipment. Netsens srl (“the applicant”) certifies that, as of the date of the filing of the application, the applicant is not identified on the Covered List as an entity producing “covered” equipment. Signed: Printed name: Antonio Manes Title: CEO Company Name: Netsens srl Date: 06/05/2023

Cover Letter(s)

1 Netsens s.r.l. – via delle Cantine 97 Calenzano (FI) – Italy Tel +39 055 3437042 – Fax +39 055 3416085 Cod.Fisc / P.IVA / CCIAA: 05475380480 – REA: FI-549634 RAEE IT09020000005793 - Cap. Soc. € 200.000,00 i.v. Azienda con Sistema Qualità Certificato ISO 9001:2015 e Sistema di Gestione Ambientale Certificato ISO 14001:2015 7/28/2023 Nemko North America, Inc. 303 River Road Ottawa, Ontario, Canada K1V 1H2 AUTHORITY TO ACT AS AGENT - FCC On our behalf, I appoint Irritec USA Inc., to act as our agent in the preparation of this application for equipment certification. I certify that submitted documents properly describe the device or system for which equipment certification is sought. I also certify that each unit manufactured, imported or marketed, as defined in FCC regulations will have affixed to it a label identical to that submitted for approval with this application. In signing this letter, Applicant certifies that neither the applicant nor any party to the application is not subject to a denial of Federal benefits, that include FCC benefits, pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C. § 862 because of a conviction for possession or distribution of a controlled substance. See 47 CFR 1.2002(b) for the definition of a "party" for these purposes. For instances where our authorized agent signs the application for certification on our behalf, I acknowledge that all responsibility for complying with the terms and conditions for certification, as specified by Nemko North America Inc., still resides still resides with us. Sincerely, Printed name: Antonio Manes

Cover Letter(s)

1 Netsens s.r.l. – via delle Cantine 97 Calenzano (FI) – Italy Tel +39 055 3437042 – Fax +39 055 3416085 Cod.Fisc / P.IVA / CCIAA: 05475380480 – REA: FI-549634 RAEE IT09020000005793 - Cap. Soc. € 200.000,00 i.v. Azienda con Sistema Qualità Certificato ISO 9001:2015 e Sistema di Gestione Ambientale Certificato ISO 14001:2015 Family Certification Attestation Letter 06/05/2023 Nemko Canada Inc 303 River Road Ottawa K1V 1H2 Canada ATTN.: Reviewing Engineer FCC ID: 2A6TE-MN014XEO Models: MN-0146-EO, MN-0147-EO We hereby request Family Certification for the above-mentioned Models based on them being electrically, and physically identical apart from model name/number. The MN-0146-EO model is powered using a primary (non rechargeable) battery, while the MN-0147- EO is powered using external DC power supply. No other differences are present. Signed: Printed name: Antonio Manes Title: CEO Date: 06/05/2023

Cover Letter(s)

1 Netsens s.r.l. – via delle Cantine 97 Calenzano (FI) – Italy Tel +39 055 3437042 – Fax +39 055 3416085 Cod.Fisc / P.IVA / CCIAA: 05475380480 – REA: FI-549634 RAEE IT09020000005793 - Cap. Soc. € 200.000,00 i.v. Azienda con Sistema Qualità Certificato ISO 9001:2015 e Sistema di Gestione Ambientale Certificato ISO 14001:2015 agosto 31, 2023 Nemko North America, Inc. 303 River Road Ottawa, Ontario, Canada K1V 1H2 REQUEST FOR CONFIDENTIALITY - FCC FCC ID: 2A6TE-MN014XEO Pursuant to Sections 0.457(d) and 0.459 of the Commission’s Rules and FCC Guidance document 726920, we hereby request permanent confidential treatment of exhibits identified as such in the table below and request they are permanently withheld from public review based on the documents containing trade secrets and proprietary information not customarily released to the public. The public disclosure of this information might be harmful to the applicant and provide unjustified benefits to its competitors. We also request short-term confidentiality on certain exhibits until the intended date of marketing as outlined below. We request the exhibits be withheld from public view for a period of 180 days. We attest marketing of the product will only commence after the period of short-term confidentiality expires, or if marketing is to commence before the requested number of days listed above, the grantee will inform Nemko to release the Short-Term Confidentiality information withheld on the FCC equipment authorization website. Exhibit Type of Confidentiality Requested Block Diagrams ☒ Permanent ☐ Short Term External Photos ------------------ ☐ Short Term Internal Photos ☐ Permanent* ☐ Short Term Operation Description ☒ Permanent ☐ Short Term Parts List & Placement/BOM ☒ Permanent ☐ Short Term Tune-Up Procedure ☐ Permanent ☐ Short Term Schematic Diagrams ☒ Permanent ☐ Short Term Test Setup Photos ------------------ ☐ Short Term User’s Manual ☐ Permanent* ☐ Short Term The asterisked items (*) require further information to be provided in this justification letter before permanent confidentiality will be extended to these exhibits. Please refer to FCC KDB 726920 D01 found at: https://apps.fcc.gov/oetcf/kdb/forms/FTSSearchResultPage.cfm?switch=P&id=41731 and review section II, 3) regarding specific information that must accompany these requests. Note: any documents held under the Short-Term confidentiality will automatically become public after the requested time if an appropriate extension request has not been received. Any exhibits (i.e., schematic diagrams) that may have already been requested to have “Permanent” confidentiality as shown above need not be repeated under Short-Term confidentiality request. Sincerely, Signed: Printed name: Antonio Manes Title: CEO Company Name: Netsens srl

ID Label/Location Info

QC CHECK UNIT ID: netsens Netsens s.r.l. - via delle Cantine 97 50041 Calenzano (FI) - ITALY - www.netsens.it 3.6V DC, 0.05A FCC ID: 2A6TE-MN014XEO MN-0146-EO IoT Wireless Unit This device complies with Part 15 of the FCC rules subject to the following two conditions: 1) This device may not cause harmful interference 2) This device must accept all interference received, including interference that may cause undesired operation.

ID Label/Location Info

QC CHECK UNIT ID: netsens Netsens s.r.l. - via delle Cantine 97 50041 Calenzano (FI) - ITALY - www.netsens.it 12V DC, 0.05A FCC ID: 2A6TE-MN014XEO MN-0147-EO IoT Wireless Unit This device complies with Part 15 of the FCC rules subject to the following two conditions: 1) This device may not cause harmful interference 2) This device must accept all interference received, including interference that may cause undesired operation.

Parts List/Tune Up Info

1 Netsens s.r.l. – via delle Cantine 97 Calenzano (FI) – Italy Tel +39 055 3437042 – Fax +39 055 3416085 Cod.Fisc / P.IVA / CCIAA: 05475380480 – REA: FI-549634 RAEE IT09020000005793 - Cap. Soc. € 200.000,00 i.v. Azienda con Sistema Qualità Certificato ISO 9001:2015 e Sistema di Gestione Ambientale Certificato ISO 14001:2015 FCC ID: Product Name: Tune up Informations Netsens IoT wireless data detection unit MN-0146-EO is designed so that the switching range matches the alignment range. No tune up procedure is required by technicians or users after the equipment has left the factory to match its specifications on the working frequency. No manual trimmers or adjustments that can be manually done are implemented. Date 05/08/2023 Company name Netsens srl Name and Surname Antonio Manes Position/Function CEO Signature________________________

RF Exposure Info

Manufacturer: Name: Oscar Frau Product: Title: Project Handler FCC ID: Signature: MPE limits (§1.1310) Mode Frequency Duty Cycle Power Antenna Gain 4, 5 EIRP 1 EIRP Distance PD 2 PD Limit 3 Margin 2.1091 EIRP Limit 2.1091 EIRP Margin PD/PD Limit Worst PD/PD values to be considered MHz % dBm dBi dBm mW cm mW/cm 2 mW/cm 2 dB mW dB MN-0146-EO 4 903,0 100 12,0 2,6 14,60 28,8 20 0,006 0,602 20,21 758 14,20 0,00953 0,00953 MN-0147-EO 5 907,8 100 13,5 2,6 16,10 40,7 20 0,008 0,605 18,73 762 12,72 0,01339 0,01339 FCC Co-Location = 0,02292 < 1 1 EIRP = ( Power dBm + Antenna Gain dBi ) + 10 x Log ( Duty Cycle % / 100 ) 2 PD = EIRP / (4xπxD 2 ) 3 CFR 47 Part 1, §1.1310(e), table 1 4 See Report No.: REP009880, §8.6.5 5 See Report No.: REP009881, §8.6.5 2.1091 EIRP Limit 1.1307 (b)(3)(i)(C) exemption limit RF Source Frequency F R λ λ/2π R/(λ/2π) Threshold ERP Threshold EIRP Threshold EIRP EIRP Margin MHz MHz m m m W W mW mW dB 300-1500 903,0 0,20 0,332 0,0529 3,78 0,46234 0,758 758 28,8 14,20 907,8 0,20 0,330 0,0526 3,80 0,46479 0,762 762 40,7 12,72

Test Report

Choose Scandinavian trust RADIO TEST REPORT – REP009880 Type of assessment: Final product testing Applicant: Netsens Srl Via delle Cantine, 97 50041 Calenzano (FI) – Italy Product: IoT wireless data detection unit Model: MN-0146-EO FCC ID: 2A6TE-MN014XEO Specifications:  FCC 47 CFR Part 15 Subpart C, §15.247 Date of issue: April 13, 2023 P. Barbieri Tested by Signature D. Guarnone Reviewed by Signature Report reference ID: REP009880 Page 2 of 60 Lab locations Company name Nemko Spa Address Via del Carroccio, 4 City Biassono Province MB Postal code 20853 Country Italy Telephone +39 039 220 12 01 Facsimile +39 039 220 12 21 Website www.nemko.com Test site registration 682159 Limits of responsibility Note that the results contained in this report relate only to the items tested and were obtained in the period between the date of initial receipt of samples and the date of issue of the report. This test report has been completed in accordance with the requirements of ISO/IEC 17025. All results contain in this report are within Nemko Spa ISO/IEC 17025 accreditation. Copyright notification Nemko Spa authorizes the applicant to reproduce this report provided it is reproduced in its entirety and for use by the company’s employees only. Any use which a third party makes of this report, or any reliance on or decisions to be made based on it, are the responsibility of such third parties. Nemko Spa accepts no responsibility for damages, if any, suffered by any third party as a result of decisions made or actions based on this report. Report reference ID: REP009880 Page 3 of 60 Table of Contents Table of Contents ......................................................................................................................................................................................................... 3 Report summary ................................................................................................................................................................................. 4 1.1 Test specifications .................................................................................................................................................................................................... 4 1.2 Test methods ............................................................................................................................................................................................................ 4 1.3 Exclusions ................................................................................................................................................................................................................. 4 1.4 Statement of compliance .......................................................................................................................................................................................... 4 1.5 Test report revision history ....................................................................................................................................................................................... 4 Engineering considerations ................................................................................................................................................................. 5 2.1 Modifications incorporated in the EUT for compliance ............................................................................................................................................ 5 2.2 Technical judgment .................................................................................................................................................................................................. 5 2.3 Deviations from laboratory tests procedures ........................................................................................................................................................... 5 Test conditions ................................................................................................................................................................................... 6 3.1 Atmospheric conditions ............................................................................................................................................................................................ 6 3.2 Power supply range .................................................................................................................................................................................................. 6 Measurement uncertainty .................................................................................................................................................................. 7 4.1 Uncertainty of measurement ................................................................................................................................................................................... 7 Information provided by the applicant ................................................................................................................................................ 8 5.1 Disclaimer ................................................................................................................................................................................................................. 8 5.2 Applicant/Manufacture ............................................................................................................................................................................................ 8 5.3 EUT information ....................................................................................................................................................................................................... 8 5.4 Radio technical information..............................................................................................................................…

Text truncated - open the document above for the full version.

Test Report

C h o o s e S c a n d i n a v i a n t r u s t RADIO TEST REPORT – REP009881 Type of assessment: Final product testing Applicant: Netsens Srl Via delle Cantine, 97 50041 Calenzano (FI) – Italy Product: IoT wireless data detection unit Model: MN-0147-EO FCC ID: 2A6TE-MN014XEO Specifications:  FCC 47 CFR Part 15 Subpart C, §15.247 Date of issue: April 13, 2023 P. Barbieri Tested by Signature D. Guarnone Reviewed by Signature Report reference ID: REP009881 Page 2 of 63 Lab locations Company name Nemko Spa Address Via del Carroccio, 4 City Biassono Province MB Postal code 20853 Country Italy Telephone +39 039 220 12 01 Facsimile +39 039 220 12 21 Website www.nemko.com Test site registration 682159 Limits of responsibility Note that the results contained in this report relate only to the items tested and were obtained in the period between the date of initial receipt of samples and the date of issue of the report. This test report has been completed in accordance with the requirements of ISO/IEC 17025. All results contain in this report are within Nemko Spa ISO/IEC 17025 accreditation. Copyright notification Nemko Spa authorizes the applicant to reproduce this report provided it is reproduced in its entirety and for use by the company’s employees only. Any use which a third party makes of this report, or any reliance on or decisions to be made based on it, are the responsibility of such third parties. Nemko Spa accepts no responsibility for damages, if any, suffered by any third party as a result of decisions made or actions based on this report. Report reference ID: REP009881 Page 3 of 63 Table of Contents Table of Contents ......................................................................................................................................................................................................... 3 Report summary ................................................................................................................................................................................. 4 1.1 Test specifications .................................................................................................................................................................................................... 4 1.2 Test methods ............................................................................................................................................................................................................ 4 1.3 Exclusions ................................................................................................................................................................................................................. 4 1.4 Statement of compliance .......................................................................................................................................................................................... 4 1.5 Test report revision history ....................................................................................................................................................................................... 4 Engineering considerations ................................................................................................................................................................. 5 2.1 Modifications incorporated in the EUT for compliance ............................................................................................................................................ 5 2.2 Technical judgment .................................................................................................................................................................................................. 5 2.3 Deviations from laboratory tests procedures ........................................................................................................................................................... 5 Test conditions ................................................................................................................................................................................... 6 3.1 Atmospheric conditions ............................................................................................................................................................................................ 6 3.2 Power supply range .................................................................................................................................................................................................. 6 Measurement uncertainty .................................................................................................................................................................. 7 4.1 Uncertainty of measurement ................................................................................................................................................................................... 7 Information provided by the applicant ................................................................................................................................................ 8 5.1 Disclaimer ................................................................................................................................................................................................................. 8 5.2 Applicant/Manufacture ............................................................................................................................................................................................ 8 5.3 EUT information ....................................................................................................................................................................................................... 8 5.4 Radio technical information..........................................................................................................…

Text truncated - open the document above for the full version.

Test Report

1 Netsens s.r.l. – via delle Cantine 97 Calenzano (FI) – Italy Tel +39 055 3437042 – Fax +39 055 3416085 Cod.Fisc / P.IVA / CCIAA: 05475380480 – REA: FI-549634 RAEE IT09020000005793 - Cap. Soc. € 200.000,00 i.v. Azienda con Sistema Qualità Certificato ISO 9001:2015 e Sistema di Gestione Ambientale Certificato ISO 14001:2015 Typology Meander line, printed Layout See Figure 1 Mechanical characteristics 35 μm copper over FR4 laminate, HAL finished Operational BW 80 MHz Maximum gain 2.6 dB H plane @915Mhz Characteristic impedance 50 Ω nominal Connector NA, Integrated Radiation pattern E/H See below Max gain in operational BW 2.6 dB NOTE: All measurements were performed radiated. Models MN-0146-EO (powered by a primary non-rechargeable battery) and MN-0147-EO (powered by external DC power supply), which are filed under the FCC ID: 2A6TE-MN014XEO, have EIRP measurements similar, but not equal, due to internal mismatching and mutual coupling between the printed antenna and the electrical surrounding. In filed test reports, the reported antenna gain must be intended as “rated”. Antenna radiation pattern normalized to max gain Max gain H plane=2.5 dB F= 915 MHz -------Horizontal -------Vertical 2 Netsens s.r.l. – via delle Cantine 97 Calenzano (FI) – Italy Tel +39 055 3437042 – Fax +39 055 3416085 Cod.Fisc / P.IVA / CCIAA: 05475380480 – REA: FI-549634 RAEE IT09020000005793 - Cap. Soc. € 200.000,00 i.v. Azienda con Sistema Qualità Certificato ISO 9001:2015 e Sistema di Gestione Ambientale Certificato ISO 14001:2015 PCB ANTENNA 915 Figure 1 Antenna layout [mm] Figure 1. PCB lay-out (mm)

Contact Information

Applicant

Antonio Manes(CEO)
[email protected]+390553437042Fax: +390553437042

Test Firm

Nemko S.p.A.Roberto Giampaglia
[email protected]+39 039 220 12 01Fax: +39 039 220 12 21

Technical Specifications

#Rule PartsFrequency RangePower Output
115C903 MHz - 914.2 MHz22.00 mW
Confidentiality
Long Term
Grant Notes
Power listed is conducted. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other transmitter, except in accordance with FCC multi-transmitter product procedures. End users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance.