CFR 47 §2.911 (d)(5) Attestation To: Federal Communications Commission 7435 Oakland Mills Road Columbia, MD 21046 USA Date: FCC ID: FRN: July 8, 2025 2A6WXWCMIT31A 0032412702 1.BH EVS CO.,LTD. certifies that the equipment for which authorization is sought is not “covered” equipment prohibited from receiving an equipment authorization pursuant to section 2.903 of the FCC rules. 2.BH EVS CO.,LTD. certifies that, as of the date of the filing of the application, the applicant is not identified on the Covered List as an entity producing “covered” equipment and is not an affiliate or subsidiary of an entity identified on the Covered List. 3.BH EVS CO.,LTD. certifies that, the device does not have cybersecurity and /or anti-virus software produced or provided by Kaspersky Lab, Inc. or any of its successors and assignees, identified on the Covered List installed on the device, nor will it be installed by the applicant anytime after certification. Sincerely yours, Name: Job Title: JUNGAH KI Senior Research Eng. Company Name: BH EVS CO.,LTD.
Date: July 08, 2025 Federal Communications Commision Equipment Authorization branch 7435 Oakland Mills Road Columbia, MD 21046 T o whom it may concern: I, t he undersigned , hereby authorize UL Korea, Ltd. Suwon Laboratory to act on our behalf in all man ner s rela ting to application for equipment authorization, includin g si gning of all documents relating to these matters. Any and all acts carried out by UL Korea, Ltd. Suwon Laboratory on our behalf shall have the same effect as acts of our own. I, the undersigned, hereby certify that we are not subject to a denial of federal benefits, that includes FCC benefits, pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C. 853(a). In authorizing UL Korea as our representative, we still recognize that we are responsible to: a)comply with the relevant provisions of the certification program; b)make all necessary arrangements for the conduct of the evaluation, including provision for examining documentation and access to all areas, records (including internal audit reports) and personnel for the purposes of evaluation (e.g. testing, inspection, assessment, surveillance, reassessment) and resolution of complaints; c)make claims regarding certification only in respect of the scope for which certification has been granted; d)do not use our product certification in such a manner as to bring the Certification Division into disrepute and not make any statement regarding our product certification which the Certification Division may consider misleading or unauthorized; e)upon suspension or cancellation of certification, discontinue use of all advertising matter that contains any reference thereto and return any certification documents as required by the Certification Division; f)use certification only to indicate the products are certified as being in conformity with specified standards; g)endeavor to ensure that no certificate or report nor any part thereof is used in a misleading manner; h)ensure that any reference to our product certification in communication media such as documents, brochures or advertising, complies with the requirements of the Certification Division; i)keep a record of all complaints made known to the us relating to the product’s compliance with requirements of the relevant standard and to make these records available to the when requested; j)take appropria te action with respect to such complaints and any deficiencies found in products or services that affect compli ance with the requirements for certification; k)document the actions taken. This au thorization is valid until furt her written notice from the applicant. Sincerely Yours, Name: JUNG-AH KI Title: Senior Research Engineer E-mail: [email protected] BH EVS CO.,LTD.
Date: 7/8/2025 Attn: FCC Office of Engineering and Technology / UL Verification Services TCB Subject: Request for Confidentiality FCC ID: 2A6WXWCMIT31A To Whom It May Concern: Pursuant to the provisions of Sections 0.457 and 0.459 of the Commission’s rules (47 CFR §§ 0.457, 0 .459), we are requesting the Commission to withhold the following attachments as confidential document from public disclosure indefinitely. •Schematic Diagram •Block Diagram •Theory of Operation •Part List Above mentioned document contains detailed system and equipment description are considered as proprietary information in operation of the equipment. The public disclosure of above documents might be harmful to our company and would give competitor an unfair advantage in the market. In additional to above mentioned documents, pursuant to Public Notice DA 04-1705 of the Commission’s policy, in order to comply with the marketing regulations in 47 CFR §2.803 and the importation rules in 47 CFR §2.1204, while ensuring that business sensitive information remains confidential until the actual marketing of newly authorized devices. We are requesting the commission to grant short-term confidentiality request on the following attachments until 180 days after issue date. •External Photos •Internal Photos •Test Setup Photos •User Manual It is our understanding that all measurement test reports, FCC ID label format and correspondent during certification review process cannot be granted as confidential documents and those information will be available for public review once the grant of equipment authorization is issued. Best Regards JungAh K i Senior Reseach Engineer
LABEL National Conformity marks FCC ID: 2A6WXWCMIT31A IC: 28559-WCMIT31A R10-XXXXXXX *Silk sticker *Laser marked
Testing Laboratory TL-637 FCC 47 CFR § 2.1093 SAR REPORT (WPT evaluation) FOR Wireless Charger + NFC MODEL NUMBER: WCMIT31A FCC ID : 2A6WXWCMIT31A REPORT NUMBER: S-4791776982-S1V3 ISSUE DATE: 2025-09-03 Prepared for BH EVS Co.,Ltd 5, Magokjungang 8-ro 5-gil, Gangseo-gu, Seoul, 07794 Republic of Korea Prepared by UL Korea, Ltd. 26th floor, 152, Teheran-ro, Gangnam-gu Seoul, 06236, Korea Suwon Test Site: UL Korea, Ltd. Suwon Laboratory 218 Maeyeong-ro, Yeongtong-gu, Suwon-si, Gyeonggi-do, 16675, Korea TEL: (031) 337-9902 FAX: (031) 213-5433 Report No.: S-4791776982-S1V3 Issue Date: 2025-09-03 Page 2 of 17 UL Korea, Ltd. Suwon Laboratory Doc. No.: 1.0(04) This report shall not be reproduced except in full, without the written approval of UL Korea, Ltd. Revision History Rev. Date Revisions Revised By V1 2025-07-10 Initial Issue -- V2 2025-08-01 Revised operating frequency in Sec.8 Deleted the contents of no. 3 in Sec.8 Jeongyeon Won V3 2025-09-03 Deleted the Direct exposure mode in Sec.6, Sec.7 and Sec.11 Added the test result in Sec.9 Added the equipment list in Sec.4.3 Revised the test result in Sec11.3 Jeongyeon Won Report No.: S-4791776982-S1V3 Issue Date: 2025-09-03 Page 3 of 17 UL Korea, Ltd. Suwon Laboratory Doc. No.: 1.0(04) This report shall not be reproduced except in full, without the written approval of UL Korea, Ltd. Table of Contents 1. Attestation of SAR Results ......................................................................................................... 4 2. Test Specification, Methods and Procedures ............................................................................ 5 3. Facilities and Accreditation ........................................................................................................ 5 4. DASY module WPT Test System & Test equipment ................................................................. 6 4.1 E-field and H-field measurement System ................................................................................... 6 4.1.1 Incident E-field and H-field measurement & extrapolation using MAGPy probe. ......................... 9 4.2 Simulated Internal E-field and SAR based on DASY module WPT S/W ...................................... 10 4.3 Test Equipment ........................................................................................................................... 10 5. Measurement & Simulation Uncertainty .................................................................................. 11 5.1 Incident E-/H-field Measurement Uncertainty ............................................................................... 11 5.2 Internal E-field and 1g SAR Simulation Uncertainty ..................................................................... 12 6. DUT Information ........................................................................................................................ 13 7. RF Exposure Conditions (Test Configurations) ...................................................................... 13 8. KDB 680106 D01 Equipment Approval Considerations .......................................................... 13 9. System verification ................................................................................................................... 14 10. Maximum Permissive Exposure test Results .......................................................................... 15 10.1 FCC Limit and Summary ............................................................................................................ 15 11. RF exposure test results ........................................................................................................... 16 11.1. MPE results .......................................................................................................................... 16 11.2. SAR results (1g SAR) ........................................................................................................... 16 11.3. Extrapolation Verification results .......................................................................................... 16 Appendixes .......................................................................................................................................... 17 S-4791776982-S1 FCC SAR App A Test photos ................................................................................. 17 S-4791776982-S1 FCC SAR App B Test Plots ................................................................................... 17 S-4791776982-S1 FCC SAR App C System Plots .............................................................................. 17 S-4791776982-S1 FCC SAR App D Probe Certi ................................................................................. 17 S-4791776982-S1 FCC SAR App E Source Certi................................................................................ 17 Report No.: S-4791776982-S1V3 Issue Date: 2025-09-03 Page 4 of 17 UL Korea, Ltd. Suwon Laboratory Doc. No.: 1.0(04) This report shall not be reproduced except in full, without the written approval of UL Korea, Ltd. 1. Attestation of SAR Results Applicant Name BH EVS Co.,Ltd FCC ID 2A6WXWCMIT31A Model Number WCMIT31A Applicable Standards FCC 47 CFR § 2.1093 KDB 680106 D01 RF Exposure Wireless Charging Apps Assessment method Basic restriction evaluation SAR Limit 1g SAR (W/kg) General population / Uncontrolled exposure 1.6 RF exposure conditions The highest SAR Results 1g SAR (W/kg) SAR (=at 0 cm test distance) <0.01 Date Tested 2025-05-08 to 2025-09-01 Test Results Pass UL Korea, Ltd. tested the above equipment in accordance with the requirements set forth in the above standards. All indications of Pass/Fail in this report are opinions expressed by UL Korea, Ltd. based on interpretations and/or observations of test results. Measurement Uncertainties were not taken into account and are published for informational purposes only. The test results show that the equipment tested is capable of demons…
Text truncated - open the document above for the full version.
CERTIFICATION TEST REPORT Report Number. : S-4791776982-FR1V5 Applicant : BH EVS Co.,Ltd 5, Magokjungang 8-ro 5-gil, Gangseo-gu, Seoul, 07794 Republic of Korea Model : WCMIT31A FCC ID : 2A6WXWCMIT31A EUT Description : Wireless Charger Test Standard(s) : FCC 47 CFR PART 15 SUBPART C Date Of Issue: 2025-08-13 Prepared by: UL KOREA LTD. 26th floor, 152, Teheran-ro, Gangnam-gu Seoul, 06236, Korea Suwon Test Site: UL KOREA LTD. Suwon Laboratory 218 Maeyeong-ro, Yeongtong-gu, Suwon-si, Gyeonggi-do, 16675, Korea TEL: (031) 337-9902 FAX: (031) 213-5433 REPORT NO: S-4791776982-FR1V5 DATE: 2025-08-13 FCC ID: 2A6WXWCMIT31A Page 2 of 17 UL KOREA LTD. Suwon Laboratory FORM ID: FCC_15C (05) 218 Maeyeong-ro, Yeongtong-gu, Suwon-si, Gyeonggi-do, 16675, Korea TEL: (031) 337-9902 FAX: (031) 213-5433 UL KOREA LTD. Confidential This report shall not be reproduced except in full, without the written approval of UL KOREA LTD. Revision History Rev. Issue Date Revisions Revised By V1 2025-07-04 Initial issue SunGeun Lee V2 2025-07-25 Updated to address TCB’s question SunGeun Lee V3 2025-08-01 Updated to address TCB’s question SunGeun Lee V4 2025-08-05 Updated to address TCB’s question SunGeun Lee V5 2025-08-13 ANSI C63.30 → ANSI C63.10 SunGeun Lee REPORT NO: S-4791776982-FR1V5 DATE: 2025-08-13 FCC ID: 2A6WXWCMIT31A Page 3 of 17 UL KOREA LTD. Suwon Laboratory FORM ID: FCC_15C (05) 218 Maeyeong-ro, Yeongtong-gu, Suwon-si, Gyeonggi-do, 16675, Korea TEL: (031) 337-9902 FAX: (031) 213-5433 UL KOREA LTD. Confidential This report shall not be reproduced except in full, without the written approval of UL KOREA LTD. TABLE OF CONTENTS 1. ATTESTATION OF TEST RESULTS ................................................................................. 4 2. TEST METHODOLOGY ..................................................................................................... 5 3. FACILITIES AND ACCREDITATION ................................................................................. 5 4. CALIBRATION AND UNCERTAINTY ................................................................................ 6 4.1. MEASURING INSTRUMENT CALIBRATION .............................................................. 6 4.2. SAMPLE CALCULATION ............................................................................................ 6 4.3. MEASUREMENT UNCERTAINTY ............................................................................... 6 4.4. DECISION RULE ......................................................................................................... 6 5. EQUIPMENT UNDER TEST ............................................................................................... 7 5.1. DESCRIPTION OF EUT .............................................................................................. 7 5.2. MAXIMUM E-FIELD STRENGTH ................................................................................ 7 5.3. WORST-CASE CONFIGURATION AND MODE .......................................................... 7 5.4. MODIFICATIONS ........................................................................................................ 8 5.5. DESCRIPTION OF TEST SETUP ................................................................................ 8 6. TEST AND MEASUREMENT EQUIPMENT ....................................................................... 9 7. 20dB BANDWIDTH ...........................................................................................................10 8. APPLICABLE LIMITS AND TEST RESULTS ...................................................................11 8.1. RADIATED EMISSIONS .............................................................................................11 REPORT NO: S-4791776982-FR1V5 DATE: 2025-08-13 FCC ID: 2A6WXWCMIT31A Page 4 of 17 UL KOREA LTD. Suwon Laboratory FORM ID: FCC_15C (05) 218 Maeyeong-ro, Yeongtong-gu, Suwon-si, Gyeonggi-do, 16675, Korea TEL: (031) 337-9902 FAX: (031) 213-5433 UL KOREA LTD. Confidential This report shall not be reproduced except in full, without the written approval of UL KOREA LTD. 1. ATTESTATION OF TEST RESULTS COMPANY NAME: BH EVS Co.,Ltd EUT DESCRIPTION: Wireless Charger MODEL NUMBER: WCMIT31A SERIAL NUMBER: Proto Type (RADIATED) DATE TESTED: 2025-07-01 ~ 2025-07-25 APPLICABLE STANDARDS STANDARD TEST RESULTS 47 CFR Part 15 Subpart C Complies UL KOREA LTD. tested the above equipment in accordance with the requirements set forth in the above standards. All indications of Pass/Fail in this report are opinions expressed by UL KOREA LTD. based on interpretations and/or observations of test results. Measurement Uncertainties were not taken into account and are published for informational purposes only. The test results show that the equipment tested is capable of demonstrating compliance with the requirements as documented in this report. Note: The results documented in this report apply only to the tested sample, under the conditions and modes of operation as described herein. This document may not be altered or revised in any way unless done so by UL KOREA LTD. and all revisions are duly noted in the revisions section. Any alteration of this document not carried out by UL KOREA LTD. will constitute fraud and shall nullify the document. This report must not be used by the client to claim product certification, approval, or endorsement by IAS, any agency of the Federal Government, or any agency of any government. Approved & Released For UL KOREA LTD. By: Tested By: Seokhwan Hong Sungeun Lee Suwon Lab Engineer Suwon Lab Engineer UL Korea, Ltd. UL Korea, Ltd. REPORT NO: S-4791776982-FR1V5 DATE: 2025-08-13 FCC ID: 2A6WXWCMIT31A Page 5 of 17 UL KOREA LTD. Suwon Laboratory FORM ID: FCC_15C (05) 218 Maeyeong-ro, Yeongtong-gu, Suwon-si, Gyeonggi-do, 16675, Korea TEL: (031) 337-9902 FAX: (031) 213-5433 UL KOREA LTD. Confidential This report shall not be reproduced except in full, without the written approval of UL KOREA LTD. 2. TEST METHODOLOGY The tests documented in th…
Text truncated - open the document above for the full version.
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 0.128 MHz - 0.128 MHz | - |