FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. SBN Technology Pty Ltd/
  3. 2A733-STOMP-2

2A733-STOMP-2AxIT Stomp-IT device

SBN Technology Pty Ltd
AxIT Stomp-IT device - FCC ID 2A733-STOMP-2 - SBN Technology Pty Ltd
Click to zoom

Application Details

Equipment Class
DTS - Digital Transmission System
Date of Grant
Dec 15, 2022
Application Purpose
Original Equipment
Date of Application
Dec 15, 2022
Equipment Note
AxIT Stomp-IT device
Frequency Range
2402.00000000 - 2480.00000000
Company
SBN Technology Pty Ltd
Country
Australia

Documents & Files

Select a file to view

Users Manual

↗

Cover Letter(s)

↗
↗
↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗
↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

Quick Start Guide and Tour strengthbynumbers.com/axitsystem v2.5 Get to know your devices! Red LED Green LED Charging Indicator Activity Indicator 1 2 3 USB Charging Port Setting up your AxIT App 1/ Turn on your tablet and unlock the home screen by using an ‘S’ pattern 2/ Once unlocked, find the AxIT App located on the home screen and tap to open the app 3/ Log-in to your AxIT App with the email address and your password you signed up with. Setting up your AxIT App 4/ Click the button in the top right corner to open the Settings 5/ On the left hand side of the screen is the list of settings pages (see Guide To Settings for details on these). Click the button to open the Database management page 6/ Set-up your backup and Google Account. Click on the “Choose Account” button on the right hand side of the Database management page, and add your Google-based account. This will enable you to save backup to your Google account’s Drive so you won’t lose your data if your tablet is lost, stolen or damaged. Logging into your Google account here will also log you into the Google Playstore on the tablet for app updates, so that you always have the latest and greatest AxIT features! Check your devices 1/ Your AxIT devices are always in ‘on mode’ and ready to use when charged – there is no power button. Firstly, confirm that the devices are on by checking that the green LED (1) is blinking once intermittently. 2/ If any of the AxIT devices are not blinking, they may need to be charged via the USB port on the device (3) and the USB charger provided. You can see the charge status of your devices in the tablet notifications by swiping down from the top of the tablet. To update the battery charge status of a particular device, tap on its icon in the notification menu. Note - the devices will not operate whilst charging. You are ready to AxIT! You are now ready to start using the world's most complete assessment system. Tap "New Client" to create a new client profile and start testing. Quick steps to get the most out of your AxIT system Step 1: Log into the AxIT online portal at www.strengthbynumbers.com/login with the email and password you created when you purchased the AxIT System (this is different to your AxIT app login) Step 2: Complete the online training in the AxIT Training Portal Step 3: Join and ask questions in the AxIT Allies Facebook Community Step 4: Head to the AxIT Promo Portal to find lots of material to help you promote the AxIT system in your community. If you have any problems, tap "Need Help?" on the front page of the AxIT app or log-in to the AxIT Help Centre at www.strengthbynumbers.com/login for step by step solutions to all of our most common questions. You can also arrange a time to speak to our support team if you can't find the answer you need in the AxIT Help Centre. --- Guide to the Settings Page This is where you can set up your business details including add a logo to be displayed on all reports. This is where you can see the Clients that have been saved in the system, edit or delete their details. This is where you can duplicate, rename and create custom variations of tests for your AxIT Testing. This is where you can set-up your own Custom Playlists of selected tests to streamline your testing. These will appear in the tab in the Session playlist selection page for use. This is where you can set-up and restore a database backup using a Google-based account. This is where you can see the devices which are currently set-up in your system. You can check connection and calibrate the devices here if needed. This page provides system and account information regarding your AxIT Software. ATTENTION Always inspect devices to ensure they are in proper working order prior to each use to ensure safe operation and longevity of your devices. Do not exceed the device load capacities as shown on page two of this manual and in the AxIT app as permanent device damage may occur. REGULATORY INFORMATION STOMP-2 FCC ID: 2A733-STOMP-2 This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. N OTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: —Reorient or relocate the receiving antenna. —Increase the separation between the equipment and receiver. —Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. —Consult the dealer or an experienced radio/TV technician for help. You can access regulatory details of your products at: www.strengthbynumbers.com/pages/regulatory. Warning: Any changes or modifications not expressively approved by the grantee could void the user's authority to operate this equipment

Cover Letter(s)

EMC Technologies Pty Ltd, 176 Harrick Road, Keilor Park VIC 3042 Australia www.emctech.com.au To: Federal Communications Commission Attention: Certification Officer Date: August 9, 2022 EMC Ref: M2206030 Subject: FCC FILING – FCC ID: 2A733-Stomp-2 (Original certification) Company: SBN Technology Pty Ltd FCC ID : FCC ID: 2A733-Stomp-2 SBN Technology Pty Ltd is applying for original certification of the Stomp-IT device, designed for use in allied health and fitness settings (measuring forces generated through activities such as squats, lunges, jumps, etc). EUT Transmitter Details: • Type: Bluetooth Low Energy • Operating Freq: 2402 – 2480 MHz • Antenna: Mini Flexible Wi-Fi antenna with uFL connector. EMC Technologies is acting as agent for SBN Technology Pty Ltd in this application. Regards _____________ Shabbir Ahmed CEO EMC Technologies Pty Ltd 176 Harrick Road, Keilor Park, VIC 3042 Australia Ph: +61 3 9365 1000 www.emctech.com.au EMC Technologies Pty Ltd ABN 82 057 105 549 176 Harrick Road, Keilor Park, VIC 3042 Australia Ph: + 613 9365 1000 Fax: + 613 9331 7455 Email: [email protected]

Cover Letter(s)

SBN TECHNOLOGY PTY LTD ABN 80 624 009 598 strengthbynumbers.com Federal Communications Commission Authorization and Evaluation Division Date: 27/07/2022 Confidentiality Request regarding application for certification of FCC ID: 2A733-STOMP-2. Pursuant to Sections 0.457 and 0.459 of the Commission’s Rules, we hereby request confidential treatment of information accompanying this application as outlined below: Exhibit Type File Name Block Diagram Schematics Operational Description Block Diagram 4C SBN-4C v1.2-SCH SBN STOMP-2 Description.pdf The above materials contain trade secrets and proprietary information not customarily released to the public. The public disclosure of these materials may be harmful to the applicant and provide unjustified benefits to its competitors. The applicant understands that pursuant to Section 0.457 of the Rules, disclosure of this application and all accompanying documentation will not be made before the date of the Grant for this application. Sincerely, Jordan Thurgood

Cover Letter(s)

SBN TECHNOLOGY PTY LTD ABN 80 624 009 598 strengthbynumbers.com Federal Communications Commission Authorization and Evaluation Division Date: 08/08/2022 FCC ID: 2A733-STOMP-2 We will be using E-label for this product. Instructions to access the label can be find in the printed Quick Start Guide (User Manual) that is supplied with the product as well as in the Settings section of the companion app. Additionally the regulatory information can be found at www.strengthbynumbers.com/pages/regulatory This device complies with Part 15 of the FCC Rules Operation is subject to the following two conditions: (1) This device may not cause interference; and (2) This device must accept any interference, including interference that may cause undesired operation of the device. Sincerely, Jordan Thurgood

Cover Letter(s)

SBN TECHNOLOGY PTY LTD ABN 80 624 009 598 strengthbynumbers.com Federal Communications Commission Authorization and Evaluation Division 1435 Oakland Mills Road Columbia, MD 21046 Date: 27/07/2022 SUBJECT: FCC Application for FCC ID: 2A733-STOMP-2 To Whom It May Concern: We, the undersigned, hereby authorize Shabbir Ahmed at EMC Technologies Pty Ltd to act on our behalf, to apply to the Federal Communications Commission for FCC approval of our equipment. Any and all acts carried out by Shabbir Ahmed at EMC Technologies on our behalf shall have the same effect as acts of our own. This is to advise that we are in full compliance with the Anti- Drug Abuse Act. We, the applicant, are not subject to a denial of federal benefits pursuant to Section 5301 of the Anti-Drug Act of 1988, 21 USC853a, and no party to the application is subject to a denial of federal benefits pursuant to that section. Regards, Jordan Thurgood

External Photos

Page 1 of 4 EMC ENGINEERS & LABORATORIES EMC Bayswater Pty Ltd 18/88 Merrindale Drive Croydon South, Victoria, 3136, Australia Telephone: +61 3 9761 5888 Facsimile: +61 3 8761 6547 Email: [email protected] ABN: 49 112 221 333 Photograph Annex A: External - EUT Photographs SBN Technology Pty Ltd V2.0 AxIT Stomp-IT REPORT: E2204-1437A-4 Annex A DATE: August, 2022 EMC Bayswater Test Report E2204-1437A-4 Annex A Page 2 of 4 This document may not be reproduced, except in full, without written approval from EMC Bayswater Pty Ltd. Photographs Number Photograph Description 1 EUT – External views 2 3 4 5 6 7 EMC Bayswater Test Report E2204-1437A-4 Annex A Page 3 of 4 This document may not be reproduced, except in full, without written approval from EMC Bayswater Pty Ltd. Photograph 1 Photograph 2 Photograph 3 Photograph 4 Photograph 5 Photograph 6 EMC Bayswater Test Report E2204-1437A-4 Annex A Page 4 of 4 This document may not be reproduced, except in full, without written approval from EMC Bayswater Pty Ltd. Photograph 7

ID Label/Location Info

SBN TECHNOLOGY PTY LTD ABN 80 624 009 598 strengthbynumbers.com Federal Communications Commission Authorization and Evaluation Division Date: 12/12/2022 FCC ID: 2A733-STOMP-2 We will be using E-label for this product. Instructions to access the label can be find in the printed Quick Start Guide (User Manual) as a physical document which is supplied with the product. The label can also be accessed by viewing the website www.strengthbynumbers.com/pages/regulatory. No codes or log in requirements are needed to access the regulatory information via the link. operation of the device. Sincerely, Jordan Thurgood (1) This device may not cause interference; and (2) This device must accept any interference, including interference that may cause undesired This device complies with Part 15 of the FCC Rules Operation is subject to the following two conditions: A link to this website is included in the About page of the app. While in the app, to access this link, the user clicks the Settings icon, the About tab and then the link to the website with regulatory information will appear. When a user is in the app, there is no additional log ins required to access the Settings or About page. The information on the website is secure and in a readable form. We will put the FCC ID on the shipping documents that are attached to the outside of the box when they are shipped to the customers. Regulatory information in the App (The app is required to operate the devices). On the app homepage, click on settings button: Click on the About page: On the About page a link will be located that goes to the website containing the following regulatory information: REGULATORY INFORMATION STOMP-2 This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. NOTE: This equipment has been tested and found to comply with the limits f or a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: —Reorient or relocate the receiving antenna. —Increase the separation between the equipment and receiver. —Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. —Consult the dealer or an experienced radio/TV technician for help.

Internal Photos

Page 1 of 6 EMC ENGINEERS & LABORATORIES EMC Bayswater Pty Ltd 18/88 Merrindale Drive Croydon South, Victoria, 3136, Australia Telephone: +61 3 9761 5888 Facsimile: +61 3 8761 6547 Email: [email protected] ABN: 49 112 221 333 Photograph Annex B: Internal - EUT Photographs SBN Technology Pty Ltd V2.0 AxIT Stomp-IT REPORT: E2204-1437A-4 Annex B DATE: August, 2022 EMC Bayswater Test Report E2204-1437A-4 Annex B Page 2 of 6 This document may not be reproduced, except in full, without written approval from EMC Bayswater Pty Ltd. Photographs Number Photograph Description 1 EUT – Internal views 2 3 4 5 6 7 8 9 10 11 12 13 EUT - Battery 14 EUT – View of the antenna 15 16 17 18 19 20 EMC Bayswater Test Report E2204-1437A-4 Annex B Page 3 of 6 This document may not be reproduced, except in full, without written approval from EMC Bayswater Pty Ltd. Photograph 1 Photograph 2 Photograph 3 Photograph 4 Photograph 5 Photograph 6 EMC Bayswater Test Report E2204-1437A-4 Annex B Page 4 of 6 This document may not be reproduced, except in full, without written approval from EMC Bayswater Pty Ltd. Photograph 7 Photograph 8 Photograph 9 Photograph 10 Photograph 11 Photograph 12 EMC Bayswater Test Report E2204-1437A-4 Annex B Page 5 of 6 This document may not be reproduced, except in full, without written approval from EMC Bayswater Pty Ltd. Photograph 13 Photograph 14 Photograph 15 Photograph 16 Photograph 17 Photograph 18 EMC Bayswater Test Report E2204-1437A-4 Annex B Page 6 of 6 This document may not be reproduced, except in full, without written approval from EMC Bayswater Pty Ltd. Photograph 19 Photograph 20

RF Exposure Info

Page 1 of 7 EMC ENGINEERS & LABORATORIES EMC Bayswater Pty Ltd 18/88 Merrindale Drive Croydon South, Victoria, 3136, Australia Telephone: +61 3 9761 5888 Facsimile: +61 3 8761 6547 Email: [email protected] ABN: 49 112 221 333 RF Radiation Exposure Evaluation In accordance with: CFR47 FCC Part 2, Subpart J, 2.1093 FCC KDB 447498 D01 v06 SBN Technology Pty Ltd V2.0 AxIT Stomp-IT FCC ID: 2A733-STOMP-2 REPORT: E2204-1437A-5 DATE: December, 2022 EMC Bayswater Test Report E2204-1437A-5 Page 2 of 7 Prepared by: Approved by: 13/12/2022 09:31 Adnan Zaman (EMC Test Engineer) Neville Liyanapatabendige (Manager) Date This document may not be reproduced, except in full, without written approval from EMC Bayswater Pty Ltd. RF Radiation Exposure Evaluation Report EMC Bayswater Test Report: E2204-1437A-5 Issue Date: December, 2022 Product: AxIT Stomp-IT Model No: V2.0 Serial No: D8:80:39:F5:CA:EC FCC ID: 2A733-STOMP-2 Client Details: Mr. Jordan Thurgood SBN Technology Pty Ltd Level 6, 484 St Kilda Rd, Melbourne, Victoria 3000 Australia Phone No: +61 438 329 588 e-mail: [email protected] Standard(s): CFR47 FCC Part 2, Subpart J, 2.1093 Radiofrequency radiation exposure evaluation: portable devices. FCC KDB 447498 D01 v06 RF EXPOSURE PROCEDURES AND EQUIPMENT AUTHORIZATION POLICIES FOR MOBILE AND PORTABLE DEVICES Results Summary: RF Radiation exposure requirements Complied Test Date(s): 25 th of May, 2022 Test House (Issued By): EMC Bayswater Pty Ltd 18/88 Merrindale Drive Croydon South Victoria, 3136 Australia FCC Accredited Test Firm Registration number: 527798 FCC Accredited Test Firm Designation number: AU0004 Phone No: +61 3 9761 5888 Email: [email protected] Fax: +61 3 8761 6547 Web: www.emcbayswater.com.au The SBN Technology Pty Ltd, V2.0, AxIT Stomp-IT, measured EIRP is below the SAR exception threshold (5mm distance) and the calculated power density level at a distance of 20cm are below the maximum levels allowed by regulations therefore complied with the requirements of CFR47 FCC Part 2, Subpart J, 2.1093. This is to certify that the necessary evaluations were made by EMC Bayswater Pty Ltd, and that the SBN Technology Pty Ltd, V2.0, AxIT Stomp-IT, has been tested in accordance with requirements contained in the appropriate commission regulations. EMC Bayswater Test Report E2204-1437A-5 Page 3 of 7 This document may not be reproduced, except in full, without written approval from EMC Bayswater Pty Ltd. RF Radiation Exposure Evaluation for SBN Technology Pty Ltd Contents 1. Introduction ................................................................................................................... 4 2. Test Report Revision History ........................................................................................ 4 3. Report Information ........................................................................................................ 4 4. Product Details .............................................................................................................. 5 4.1. Product Sample Details ........................................................................................... 5 4.2. Product description .................................................................................................. 5 5. SAR and RF Exposure exception evaluation ............................................................... 6 5.1. SAR exception evaluation ........................................................................................ 6 5.2. RF Exposure Evaluation (MPE) ............................................................................... 7 6. Conclusion ..................................................................................................................... 7 EMC Bayswater Test Report E2204-1437A-5 Page 4 of 7 This document may not be reproduced, except in full, without written approval from EMC Bayswater Pty Ltd. 1. Introduction RF Radiation Exposure evaluation was performed on a SBN Technology Pty Ltd, V2.0, AxIT Stomp-IT in accordance with CFR47 FCC Part 2, Subpart J, 2.1093. 2. Test Report Revision History None 3. Report Information EMC Bayswater Pty Ltd reports apply only to the specific samples tested under the stated test conditions. All samples tested were in good operating condition throughout the entire test program unless otherwise stated. EMC Bayswater Pty Ltd does not in any way guarantees the later performance of the product/equipment. It is the manufacturer's responsibility to ensure that additional production units of the tested model are manufactured with identical electrical and mechanical components. EMC Bayswater Pty Ltd shall have no liability for any deductions, inference or generalisations drawn by the clients or others from EMC Bayswater Pty Ltd issued reports. This report shall not be used to claim, constitute or imply product endorsement by EMC Bayswater Pty Ltd. This report shall not be reproduced except in full, without the written approval of EMC Bayswater Pty Ltd. This document may be altered or revised by EMC Bayswater Pty Ltd personnel only, and shall be noted in the revision section of the document. Any alteration of this document not carried out by EMC Bayswater Pty Ltd will nullify the document. EMC Bayswater Test Report E2204-1437A-5 Page 5 of 7 This document may not be reproduced, except in full, without written approval from EMC Bayswater Pty Ltd. 4. Product Details 4.1. Product Sample Details The device, as supplied by the client, is described as follows: Product: AxIT Stomp-IT Model No: V2.0 Serial No: D8:80:39:F5:CA:EC Firmware: v272 Software: AxIT App v2.8.11 Power Specifications: Battery powered, Lithium Ion 3.7V, 2000mAh (LiPol Battery Co; Battery Model LP604260) Dimensions: 400mm x 400mm x 30mm (Length x Width x Height) Weight: 6950 g EUT Type: Portable, tested as table-top Transmitter details: Description: RN4871-U Type: BLE 4.2 Modulation: GFSK Channels: Channels 0-39 (ISM Band 2.40…

Text truncated - open the document above for the full version.

Test Report

Page 1 of 77 EMC Bayswater Pty Ltd EMC ENGINEERS & LABORATORIES 18/88 Merrindale Drive Croydon South, Victoria, 3136, Australia Telephone: +61 3 9761 5888 Facsimile: +61 3 8761 6547 Email: [email protected] ABN: 49 112 221 333 EMC COMPLIANCE REPORT Certification Test Report In accordance with: CFR47 FCC Part 15, Subpart C, 15.247 SBN Technology Pty Ltd V2.0 AxIT Stomp-IT FCC ID: 2A733-STOMP-2 REPORT: E2204-1437A-4 DATE: December, 2022 Accreditation Number: 18553 Accredited for compliance with ISO/IEC 17025 - Testing The results of the tests, calibrations and/or measurements included in this document are traceable to Australian/national standards. NATA is a signatory to the ILAC Mutual Recognition Arrangement for the mutual recognition of the equivalence of testing and calibration reports. This document may not be reproduced except in full without approval from EMC Bayswater, with the exception of the certificate on page 2. EMC Bayswater Test Report E2204-1437A-4 Page 2 of 77 Prepared & tested by: Approved by: 13/12/2022 09:26 Adnan Zaman (EMC Test Engineer) Neville Liyanapatabendige (Manager) Date Accreditation number: 18553. The results of the tests, calibrations and/or measurements included in this document are traceable to Australian/national standards. NATA is a signatory to the ILAC Mutual Recognition Arrangement for the mutual recognition of the equivalence of testing, calibration and inspection reports. This document may not be reproduced except in full without approval from EMC Bayswater, with the exception of the certificate on page 2. Certificate of Compliance Certification Compliance Report EMC Bayswater Test Report: E2204-1437A-4 Issue Date: December, 2022 Test Sample(s): AxIT Stomp-IT Model No: V2.0 Serial No: D8:80:39:F5:CA:EC FCC ID: 2A733-STOMP-2 Client Details: Mr. Jordan Thurgood SBN Technology Pty Ltd Level 6, 484 St Kilda Rd, Melbourne, Victoria 3000 Australia Phone No: +61 438 329 588 e-mail: [email protected] Test Specification: CFR47 FCC Part 15, Subpart C, 15.247 Results Summary: 15.203 - Antenna requirement Complied 15.247 (a)(2) - 6dB Bandwidth Complied 15.247 (b)(3) - Maximum Output Power Complied 15.247 (d) - Out-of-Band Emissions - – 100kHz, -20dBc Complied 15.247 (d) - Emissions on the Band edge Complied 15.247 (d), 15.209 – Radiated emissions in Restricted bands Complied 15.247 (e) - Power Spectral Density Complied 15.247 (i) - Radio frequency hazard Complied Test Date(s): 19 th of 25 th of May, 2022 Test House (Issued By): EMC Bayswater Pty Ltd 18/88 Merrindale Drive Croydon South Victoria 3136 Australia FCC Accredited Test Firm Registration number: 527798 FCC Accredited Test Firm Designation number: AU0004 Phone No: +61 3 9761 5888 e-mail: [email protected] Fax No: +61 3 8761 6547 Web: www.emcbayswater.com.au/ This is to certify that the necessary measurements were made by EMC Bayswater Pty Ltd, and that the SBN Technology Pty Ltd, V2.0, AxIT Stomp-IT, has been tested in accordance with requirements contained in the appropriate commission regulations.. EMC Bayswater Test Report E2204-1437A-4 Page 3 of 77 Accreditation number: 18553. The results of the tests, calibrations and/or measurements included in this document are traceable to Australian/national standards. NATA is a signatory to the ILAC Mutual Recognition Arrangement for the mutual recognition of the equivalence of testing, calibration and inspection reports. This document may not be reproduced except in full without approval from EMC Bayswater, with the exception of the certificate on page 2. EMC Compliance Report for SBN Technology Pty Ltd Contents 1. Introduction ................................................................................................................... 5 2. Test Report Revision History ........................................................................................ 5 3. Report Information ........................................................................................................ 5 4. Summary of Results ...................................................................................................... 5 5. Product Sample Details ................................................................................................. 6 5.1. EUT Description........................................................................................................ 6 5.2. Product description ................................................................................................... 6 5.3. Support Equipment ................................................................................................... 7 5.4. Product operating modes .......................................................................................... 7 5.5. Product operating mode for testing ........................................................................... 7 5.6. Configuration ............................................................................................................ 7 5.7. Modifications ............................................................................................................. 7 6. Test Facility & Equipment ............................................................................................. 7 6.1. Test Facility .............................................................................................................. 7 6.2. Test Equipment ........................................................................................................ 7 7. Referenced Standards ................................................................................................... 8 8. Referenced Documents ................................................................................................. 8 9. Antenna Requirement – FCC Part 15.203 ..................................................................... 9 9.1. Requirements .........................................................................…

Text truncated - open the document above for the full version.

Test Report

SBN Green Flex external antenna FCC ID: 2A733-STOMP-2 2.4GHz Mini Flexible WiFi Antenna with uFL Connector - 100mm Supplier: Adafruit Product ID: 2308 Technical Details: Operating Range: 2400~2500MHz / 4900~5900MHz Efficiency: 90% Bandwidth (VSWR: 2.0 max.) 140 MHz / SWR < 2.0 Polarization: Linear Radiation: Omni directional Antenna Gain: 4DBi Impedance: 50 ohm Cable: 100mm / 4" long Antenna: 40mm x 8mm / 1.6" x 0.3" Weight: 0.7g Images:

Test Setup Photos

Page 1 of 4 EMC ENGINEERS & LABORATORIES EMC Bayswater Pty Ltd 18/88 Merrindale Drive Croydon South, Victoria, 3136, Australia Telephone: +61 3 9761 5888 Facsimile: +61 3 8761 6547 Email: [email protected] ABN: 49 112 221 333 Photograph Annex C: Test Configuration Photographs SBN Technology Pty Ltd V2.0 AxIT Stomp-IT REPORT: E2204-1437A-4 Annex C DATE: August, 2022 EMC Bayswater Test Report E2204-1437A-4 Annex C Page 2 of 4 This document may not be reproduced, except in full, without written approval from EMC Bayswater Pty Ltd. Photographs Number Photograph Description 1 Radiated measurements – Test configuration 2 Radiated measurements – 9kHz to 30MHz – X Antenna orientation 3 Radiated measurements – 9kHz to 30MHz – Y Antenna orientation 4 Radiated measurements – 9kHz to 30MHz – Z Antenna orientation 5 Radiated measurements – below 1GHz 6 Radiated measurements – above 1GHz 7 Conducted measurements EMC Bayswater Test Report E2204-1437A-4 Annex C Page 3 of 4 This document may not be reproduced, except in full, without written approval from EMC Bayswater Pty Ltd. Photograph 1 Photograph 2 Photograph 3 Photograph 4 Photograph 5 Photograph 6 EMC Bayswater Test Report E2204-1437A-4 Annex C Page 4 of 4 This document may not be reproduced, except in full, without written approval from EMC Bayswater Pty Ltd. Photograph 7

Contact Information

Applicant

Jordan Thurgood
[email protected]+61438329588Fax: +61438329588

Test Firm

EMC Bayswater Pty LtdNeville Liyanapatabendige
[email protected]61397615888Fax: 61387616547

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.40 GHz - 2.48 GHz2.00 mW
Confidentiality
Long Term
Grant Notes
Power listed is conducted.