2A73C-ZB001PTO Controller

Zuidberg Frontline Systems B.V.
PTO Controller - FCC ID 2A73C-ZB001 - Zuidberg Frontline Systems B.V.
Click to zoom

Application Details

Equipment Class
JAB - Part 15 Class B Digital Device
Date of Grant
Oct 04, 2022
Application Purpose
Original Equipment
Date of Application
Oct 02, 2022
Equipment Note
PTO Controller
Company
Zuidberg Frontline Systems B.V.
Country
Netherlands

Documents & Files

Select a file to view

Users Manual

↗
↗

Cover Letter(s)

↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗
↗

Test Report

↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

FRONT PTO SYSTEM User Manual12022-09 This document is meant to be a reference work to allow only those users who are authorised to do so to safely operate and maintain the product mentioned on the cover of this document. Keep this manual in a safe place, for example, with the other documents for your tractor. If this manual is lost, you can order a copy from your supplier. This manual provides information relating to safety, technical specifications, operation and maintenance. Please take the time to read this document carefully before using the front PTO system. This manual supplements the existing front PTO system user manual and replaces sections 6.1 and 6.2. © 2000-2022 Zuidberg Frontline Systems B.V. All rights reserved. No part of this publication may be reproduced and/or published by means of print, photocopy, microfilm or by any other means without the prior written permission of Zuidberg Frontline Systems B.V. This also applies to the accompanying drawings and diagrams. Zuidberg Frontline Systems B.V. reserves the right to change components at any time without prior or direct notification to the customer. The contents of this manual may also be amended without prior notice. Please contact your supplier for information relating to maintenance work or repairs not provided in this manual. This manual has been compiled with the utmost care, but Zuidberg Frontline Systems B.V. cannot take responsibility for any errors in this document or the associated consequences. Translation of the original manual EN FRONT PTO SYSTEM User Manual22022-09 1 Controller A controller is supplied with the front PTO system. This is used for the safe and correct en- gagement of the PTO. There are 3 types of controllers. ▪PTO Controller 3-pin ▪PTO Controller 4-pin ▪PTO Controller 8-pin The controller can be configured using a tablet or a smartphone. Download the free Zuidberg App from the App Store or Google Play Store. Follow the instructions in the app Before putting the PTO into operation, check that the controller cables are connected to the PTO and the tractor's wiring! The dealer must configure the controller before use. (For the correct connection, see the installation instructions as supplied for the installation of the front PTO system) Figure 1 3-pin controller, item number 8002006 This controller is interchangeable with the controllers with the following item numbers: 8001914 0/A 8001272 0/A 8000012 A/A 8000019A For other variants, please contact your dealer. To configure the controller or set the engagement time; see section 1.1 FRONT PTO SYSTEM User Manual32022-09 Figure 2 4-pin controller, item number 8002007 This controller is suitable to be controlled by tractor hardware and software. A resistor module must be installed with the controller. To configure the controller or set the engagement time; see section 1.1 ▪The resistor module may become hot during PTO operation, avoid direct contact at all times. ▪Always ensure that the resistor module is mounted in the open air and in the airflow of the cooling assembly. ▪Ensure that the resistor module is free from dust/grass/dirt at all times. Clean it regularly! Figure 3 EN FRONT PTO SYSTEM User Manual42022-09 Figure 4 8-pin controller, item number 8002008 This controller can only be used with a dedicated wiring harness and switches. For switch operation, see section 1.3. To configure the controller or set the engagement time; see section 1.1 1.1 Configuring the controller The tractor ignition must be switched on in order to configure the controller. The controller can be configured by the dealer using the free downloadable Zuidberg App. Scan the QR code to download the app. Once end users download the Zuidberg App, they can adjust the clutch engagement time themselves. End users can also see the total number of running hours of the tractor and of the PTO in the app. When connected to the controller via Bluetooth, the PIN code found on the controller (see Fig. 5) must be entered. Only then is it possible to configure the controller by following the steps in the app. Figure 5 FRONT PTO SYSTEM User Manual52022-09 The engagement time can be set in the app. If the front PTO system is used to drive a very light implement, the engagement time should be long so that the system engages less abruptly. In the case of heavy drive loads, the engagement time should be set as short as possible in connection with the wear of the coupling. After setting the engagement speed, the Bluetooth connection to the controller can be disconnected. Reaction Minimum Nominal Maximum Clutch Pressure Time Clutch pressure Figure 6 EN FRONT PTO SYSTEM User Manual62022-09 1.2 LED Status The controller has a status LED. It can be green, yellow or red. The table below indicates the status of the LED. Figure 7 LEDController statusMeaning Red/green flashingBluetooth connectedBluetooth connection is established. Green flickeringStandbyThe controller is configured and ready for use. Green constantActiveThe PTO is engaged. Red constantNot configuredThe controller is not configured. Use the app to program the controller. Red flashingFaultA fault has occurred. Open the app and see which fault code is displayed. Follow further instructions. Yellow flashingStart protectionStart protection engaged. Disengage the PTO. After 3 seconds, you can engage the PTO again. Yellow constantService requiredContact your dealer. FRONT PTO SYSTEM User Manual72022-09 1.3 Engaging and disengaging front PTO system The front PTO system can be engaged with the switch provided. The position and type of the switch depend on the type of tractor the front PTO system is installed on. The start protection of the front PTO system is integrated into the controller. The front PTO system will not operate automatically if the tractor engine is started while the front PTO system switch is engaged. To engage the front PTO system, first, turn off the switch and turn it back on after 3 seconds. The front PTO system must NEVER b…

Text truncated - open the document above for the full version.

Cover Letter(s)

FCC, Request for non-disclosure Date: 08-Oct-2021 RF_501, Issue 9 Page 1 of 1 Company Name: Zuidberg Frontline systems B.V. Address: Buitenveld 5 City: 8307 DE Ens Country: The Netherlands To: Telefication B.V., Dept. FCC TCB Wilmersdorf 50 7327 AC Apeldoorn The Netherlands Subject: Request for confidentiality FCC ID: Reference number: P000056040 Dear FCC TCB, 1. Long-Term Confidentiality Pursuant to 47 CFR Section 0.459(a) & (b), we hereby requests non-disclosure and confidential treatment of the following materials submitted in support of FCC certification application: Bill(s) of Material Block Diagrams Operational Description Schematic Diagrams Tune-up Procedure Above materials contain secrets, proprietary and technical information, which would customarily be guarded from competitors under 47 CFR, section 0.457(d)(2). Disclosure or publication or any portion of this company confidential material to other parties could cause substantial competitive harm and provide unjustified benefits for competitors. 2. Short-Term Confidentiality (STC) Pursuant to Public Notice DA 04-1705 of the Commission’s policy, in order to comply with the marketing regulations in 47 CFR §2.803 and the importation rules in 47 CFR §2.1204, applicant hereby requests Short-Term Confidential treatment of the following materials (See notes below): Internal Photos User’s Manual Test Set-up Photos External Photos Justification: Mentioned items can also reveal too much info to competitors Date: 5-8-2022 Name and signature of applicant: Jos Aarninkhof Notes: 1) A document or type of document can only have ONE type of confidentiality! 2) Short-Term confidentiality is in principle for 45 days from date of grant; it can be extended max 3 times (total time 180 days max.)! The planned date should stated in the RF731 application form. 3) FCC must be informed when marketing begins earlier. 4) Release takes place automatically thus extension must be requested in time. Telefication does not remind you of this! 5) Request for extension or for release must be received by Telefication at least 7 days before date of actual marketing or before expiration of the STC period

External Photos

Page 1 of 3 External Photos Product name : PTO-Controller Applicant : Zuidberg Frontline Systems B.V. Contains FCC ID :SH6MDBT42Q IC :8017A-MDBT42Q Project number: P000056040 008 External Photos Project number: P000056040 008 External Photos Page 2 of 3 Table of Contents 1 External Photos ........................................................................................................................................ 3 1.1 Top view ................................................................................................................................................ 3 1.2 Bottom view .......................................................................................................................................... 3 Project number: P000056040 008 External Photos Page 3 of 3 1 External Photos 1.1 Top view 1.2 Bottom view

ID Label/Location Info

Locatie markering en label LABEL EN LASER POSTIE F-PTO Author Date Page Jos Aarninkhof 03-08-2022 1 / 1

Internal Photos

Page 1 of 3 Internal Photos Product name : PTO-Controller Applicant : Zuidberg Frontline Systems B.V. Contains FCC ID :SH6MDBT42Q IC :8017A-MDBT42Q Project number: P000056040 007 Internal Photos Project number: P000056040 007 Internal Photos Page 2 of 3 Table of Contents 1 Internal Photos ........................................................................................................................................ 3 1.1 PCB 1 Top view ...................................................................................................................................... 3 1.2 PCB 1 Bottom view ................................................................................................................................ 3 Project number: P000056040 007 Internal Photos Page 3 of 3 1 Internal Photos 1.1 PCB Top view Note: The radio module is highlighted with a red circle 1.2 PCB Bottom view

RF Exposure Info

Page 1 of 7 FCC SAR Exclusion Report Product name : PTO-Controller Applicant : Zuidberg Frontline Systems B.V. Contains FCC ID :SH6MDBT42Q Test report No. : P000056040 004 Ver 1.0 Report number: P000056040 004 Ver 1.0 Page 1 of 7 Laboratory information Accreditation Telefication complies with the accreditation criteria for test laboratories as laid down in ISO/IEC 17025:2017. The accreditation covers the quality system of the laboratory as well as the specific activities as described in the authorized annex bearing the accreditation number L021 and is granted on 30 November 1990 by the Dutch Council For Accreditation (RvA: Raad voor Accreditatie). Telefication is designated by the FCC as an Accredited Test Firm for compliance testing of equipment subject to Certification under Parts 15 & 18. The Designation number is: NL0001. Telefication is a Wireless Device Testing laboratory recognized by Innovation, Science and Economic Development Canada to test to Canadian radio equipment requirements. The Industry Canada company number for Telefication is: 4173A. Telefication is a registered Conformity Assessment body (CAB) under the Japan-EC MRA (Agreement on Mutual Recognition between Japan and the European Community). The registration number is: 201. Documentation The test report must always be reproduced in full; reproduction of an excerpt only is subject to written approval of the testing laboratory. The documentation of the testing performed on the tested devices is archived for 10 years at Telefication Netherlands. Testing Location Test Site Kiwa Telefication BV Test Site location Wilmersdorf 50 7327 AC Apeldoorn The Netherlands Tel. +31 88998 3393 Test Site FCC NL0001 CABID NL0001 Report number: P000056040 004 Ver 1.0 Page 2 of 7 Revision History Version Date Remarks By V0.5 22-07-2022 Draft R.T V1.0 22-07-2022 Initial release R.T Report number: P000056040 004 Ver 1.0 Page 3 of 7 Table of Contents Revision History ............................................................................................................................................... 2 1 General Description ................................................................................................................................. 4 1.1 Applicant ............................................................................................................................................... 4 1.2 Manufacturer ........................................................................................................................................ 4 1.3 Tested Equipment Under Test (EUT) ..................................................................................................... 4 1.4 Applicable standards ............................................................................................................................. 4 1.5 Conclusions ........................................................................................................................................... 5 2 SAR exclusion Evaluation ......................................................................................................................... 6 2.1 Transmitter specifications ..................................................................................................................... 6 2.2 Evaluation calculations .......................................................................................................................... 7 2.3 Conclusion ............................................................................................................................................. 7 Report number: P000056040 004 Ver 1.0 Page 4 of 7 1 General Description 1.1 Applicant Client name: Zuidberg Frontline Systems B.V. Address Buitenveld 5, 8307 DE, Ens, The Netherlands Telephone: +31527253550 E-mail: [email protected] Contact name: Gerrit de Zwaan 1.2 Manufacturer Manufacturer name: Zuidberg Frontline Systems B.V. Address: Buitenveld 5, 8307 DE, Ens, The Netherlands Telephone: +31527253550 E-mail: [email protected] Contact name: Gerrit de Zwaan 1.3 Tested Equipment Under Test (EUT) Product name: PTO-Controller Brand name: Zuidberg Product type: Power Take Off Controller Variant model(s): “See Table below” Software version: - Hardware version: - Date of receipt 01-07-2022 Tests started: 04-07-2022 Testing ended: 04-07-2022 Overview variants Type Product description Trademark Type designation Variant PTO_CONTROLL ER_UNI_3-PINS Zuidberg 8002006 0 Variant PTO_CONTROLL ER_INT_4-PINS Zuidberg 8002007 0 Main PTO_CONTROLL ER_UNI_8-PINS Zuidberg 8002008 0 1.4 Applicable standards 47 CFR § 1.1307 (b)(1)(i)(A) Report number: P000056040 004 Ver 1.0 Page 5 of 7 1.5 Conclusions The sample of the product showed NO NON-COMPLIANCES to the specifications stated in paragraph 1.4 of this report. The results of the test as stated in this report, are exclusively applicable to the product items as identified in this report. Telefication accepts no responsibility for any properties of product items in this test report, which are not supported by the tests as specified in paragraph 1.4 “Applicable standards”. Assessment is performed by: Name : Raoul Tolud, MSc Review of assessment methods and report by: Name : Koray Korcum, M.Sc. The above conclusions have been verified by the following signatory: Date : 12-09-2022 Name : Koray Korcum, M.Sc. Function : Test Engineer Signature : Report number: P000056040 004 Ver 1.0 Page 6 of 7 2 SAR exclusion Evaluation 2.1 Transmitter specifications Transmitter 1 Variable (unit) Value Symbol Conducted time-averaged output power (mW) 2.26 P Time-averaged output power ERP (mW) 2.26 P ERP Operating frequency range (MHz) 2402 f Separation distance (cm) 20 d Separation distance (m) 0.3 R Note: The EUT contains a MDBT42Q-U radio module Report number: P000056040 004 Ver 1.0 Page 7 of 7 2.2 Evaluation calculations Transmitter 1 Transmitter 1 is evaluated according to method B of KDB 447498 D04 v01 Method B: 푃 푡ℎ …

Text truncated - open the document above for the full version.

RF Exposure Info

Page 1 of 6 RF Exposure Technical Brief for ISED RSS-102 (issue 5) section 2.5 Product name : PTO-Controller Applicant : Zuidberg Frontline Systems B.V. IC : 8017A-MDBT42Q Test report No. : P000056040 005 Ver 1.00 Report number: P000056040 005 Ver 1.00 Page 1 of 6 Laboratory information Accreditation Telefication complies with the accreditation criteria for test laboratories as laid down in ISO/IEC 17025:2017. The accreditation covers the quality system of the laboratory as well as the specific activities as described in the authorized annex bearing the accreditation number L021 and is granted on 30 November 1990 by the Dutch Council For Accreditation (RvA: Raad voor Accreditatie). Telefication is designated by the FCC as an Accredited Test Firm for compliance testing of equipment subject to Certification under Parts 15 & 18. The Designation number is: NL0001. Telefication is a Wireless Device Testing laboratory recognized by Innovation, Science and Economic Development Canada to test to Canadian radio equipment requirements. The Industry Canada company number for Telefication is: 4173A. Telefication is a registered Conformity Assessment body (CAB) under the Japan-EC MRA (Agreement on Mutual Recognition between Japan and the European Community). The registration number is: 201. Documentation The test report must always be reproduced in full; reproduction of an excerpt only is subject to written approval of the testing laboratory. The documentation of the testing performed on the tested devices is archived for 10 years at Telefication Netherlands. Testing Location Test Site Kiwa Telefication BV Test Site location Wilmersdorf 50 7327 AC Apeldoorn The Netherlands Tel. +31 88998 3393 Test Site FCC NL0001 CABID NL0001 Report number: P000056040 005 Ver 1.00 Page 2 of 6 Revision History Version Date Remarks By v1.00 22-07-2022 Release version R.T Report number: P000056040 005 Ver 1.00 Page 3 of 6 Table of Contents Revision History ....................................................................................................................................................... 2 Applicant ........................................................................................................................................................ 4 Manufacturer ................................................................................................................................................. 4 Tested Equipment Under Test (EUT) .............................................................................................................. 4 Calculation of the exemption limit for routine RF exposure evaluation ........................................................ 5 Conclusion ...................................................................................................................................................... 6 Report number: P000056040 005 Ver 1.00 Page 4 of 6 Applicant Client name: Zuidberg Frontline Systems B.V. Address Buitenveld 5, 8307 DE, Ens, The Netherlands Telephone: +31527253550 E-mail: [email protected] Contact name: Gerrit de Zwaan Manufacturer Manufacturer name: Zuidberg Frontline Systems B.V. Address: Buitenveld 5, 8307 DE, Ens, The Netherlands Telephone: +31527253550 E-mail: [email protected] Contact name: Gerrit de Zwaan Tested Equipment Under Test (EUT) Product name: PTO-Controller Brand name: Zuidberg Product type: Power Take Off Controller Variant model(s): “See Table below” Software version: - Hardware version: - Date of receipt 01-07-2022 Tests started: 04-07-2022 Testing ended: 04-07-2022 Overview variants Type Product description Trademark Type designation Variant PTO_CONTROLL ER_UNI_3-PINS Zuidberg 8002006 0 Variant PTO_CONTROLL ER_INT_4-PINS Zuidberg 8002007 0 Main PTO_CONTROLL ER_UNI_8-PINS Zuidberg 8002008 0 Report number: P000056040 005 Ver 1.00 Page 5 of 6 Calculation of the exemption limit for routine RF exposure evaluation Introduction The device is equipped with a certified radio module (8017A-MDBT42Q). SAR evaluation According to RSS-102 – Issue 5 March 19, 2015, clause 2.5 Exemption Limits for Routine Evaluation — SAR Evaluation, SAR evaluation is required if the separation distance between the user and/or bystander and the antenna and/or radiating element of the device is less than or equal to 20 cm, except when the device operates at or below the applicable output power level (adjusted for tune-up tolerance) for the specified separation distance defined in Table 1. Table 1: SAR evaluation — Exemption limits for routine evaluation based on frequency and separation distance Frequency (MHz) Exemption Limits (mW) At separation distance of ≤5 mm At separation distance of 10 mm At separation distance of 15 mm At separation distance of 20 mm At separation distance of 25 mm ≤300 71 mW 101 mW 132 mW 162 mW 193 mW 450 52 mW 70 mW 88 mW 106 mW 123 mW 835 17 mW 30 mW 42 mW 55 mW 67 mW 1900 7 mW 10 mW 18 mW 34 mW 60 mW 2450 4 mW 7 mW 15 mW 30 mW 52 mW 3500 2 mW 6 mW 16 mW 32 mW 55 mW 5800 1 mW 6 mW 15 mW 27 mW 41 mW Frequency (MHz) Exemption Limits (mW) At separation distance of 30 mm At separation distance of 35 mm At separation distance of 40 mm At separation distance of 45 mm At separation distance of ≥50 mm ≤300 223 mW 254 mW 284 mW 315 mW 345 mW 450 141 mW 159 mW 177 mW 195 mW 213 mW 835 80 mW 92 mW 105 mW 117 mW 130 mW 1900 99 mW 153 mW 225 mW 316 mW 431 mW 2450 83 mW 123 mW 173 mW 235 mW 309 mW 3500 86 mW 124 mW 170 mW 225 mW 290 mW 5800 56 mW 71 mW 85 mW 97 mW 106 mW Report number: P000056040 005 Ver 1.00 Page 6 of 6 Exemption Limits for Routine Evaluation – RF Exposure Evaluation RF exposure evaluation is required if the separation distance between the user and/or bystander and the device’s radiated element is greater than 20 cm, except when the device operates as follows: Operating frequency range Maximum source-based, time averaged maximum e.i.r.p Calculated range exemption limit < 20 MHz 1 W 1W ≥ 20 MHz to < 48 MHz 4.49/f 0.5 W 1 W to 0.…

Text truncated - open the document above for the full version.

Test Report

FCC and IC Test report for parts 15.109, 15.209, ICES 003 Product name : PTO-Controller Applicant : Zuidberg Frontline Systems B.V. Contains FCC ID :SH6MDBT42Q Contains IC :8017A-MDBT42Q Test report No. : P000056040 002 Ver 2.00 Report number: P000056040 002 Ver 2.00 Page 1 of 22 Laboratory information Accreditation Telefication complies with the accreditation criteria for test laboratories as laid down in ISO/IEC 17025:2017. The accreditation covers the quality system of the laboratory as well as the specific activities as described in the authorized annex bearing the accreditation number L021 and is granted on 30 November 1990 by the Dutch Council For Accreditation (RvA: Raad voor Accreditatie). Telefication is designated by the FCC as an Accredited Test Firm for compliance testing of equipment subject to Certification under Parts 15 & 18. The Designation number is: NL0001. Telefication is a Wireless Device Testing laboratory recognized by Innovation, Science and Economic Development Canada to test to Canadian radio equipment requirements. The Industry Canada company number for Telefication is: 4173A. The CABID is NL0001. Telefication is a registered Conformity Assessment body (CAB) under the Japan-EC MRA (Agreement on Mutual Recognition between Japan and the European Community). The registration number is: 201. Documentation The test report must always be reproduced in full; reproduction of an excerpt only is subject to written approval of the testing laboratory. The documentation of the testing performed on the tested devices is archived for 10 years at Telefication Netherlands. Testing Location Test Site Kiwa Telefication BV Test Site location Wilmersdorf 50 7327 AC Apeldoorn The Netherlands Tel. +31 88998 3393 Test Site FCC NL0001 CABID NL0001 Report number: P000056040 002 Ver 2.00 Page 2 of 22 Revision History Version Date Remarks By v0.50 14-07-2022 First draft R.T v1.00 15-08-2022 Final release R.T v2.00 19-09-2022 Revised - Updated clause 1.8: observation and remarks - Updated clause 1.3: description of EUT R.T Report number: P000056040 002 Ver 2.00 Page 3 of 22 Table of Contents Revision History ............................................................................................................................................... 2 Summary of Test results .................................................................................................................................. 4 1 General Description ................................................................................................................................. 5 1.1 Applicant ............................................................................................................................................... 5 1.2 Manufacturer ........................................................................................................................................ 5 1.3 Tested Equipment Under Test (EUT) ..................................................................................................... 5 1.4 Product specifications of Equipment under test ................................................................................... 6 1.5 Environmental conditions ..................................................................................................................... 6 1.6 Measurement standards ....................................................................................................................... 6 1.7 Applicable standards ............................................................................................................................. 6 1.8 Observation and remarks ...................................................................................................................... 6 1.9 Conclusions ........................................................................................................................................... 7 2 Test configuration of the Equipment Under Test ...................................................................................... 8 2.1 Test mode ............................................................................................................................................. 8 2.2 Test setups ............................................................................................................................................ 8 2.3 Equipment used in the test configuration .......................................................................................... 10 2.4 Sample calculations ............................................................................................................................. 10 3 Test results ............................................................................................................................................. 11 3.1 Radiated spurious emissions ............................................................................................................... 11 3.1.1 Limit ................................................................................................................................................ 11 3.1.2 Measurement instruments ............................................................................................................. 11 3.1.3 Test setup ....................................................................................................................................... 11 3.1.4 Test procedure ................................................................................................................................ 11 3.1.5 Measurement Uncertainty ............................................................................................................. 11 3.1.6 Peak tables of the radiated spurious emissions measurement ...................................................... 12 3.1.7 Plots of the Radiated Spurious Emissions Measurement ........................................................…

Text truncated - open the document above for the full version.

Test Setup Photos

Page 1 of 4 Test Setup Photos Product name : PTO-Controller Applicant : Zuidberg Frontline Systems B.V. Contains FCC ID :SH6MDBT42Q IC :8017A-MDBT42Q Project number: P000056040 006 Project number: P000056040 006 Page 2 of 4 Table of Contents 1 Test Setup Photos .................................................................................................................................... 3 1.1 Radiated emissions measurement 30 – 250 MHz ................................................................................ 3 1.2 Radiated emissions measurement 250 – 1000 MHz ............................................................................. 3 1.3 Radiated emissions measurement 1 – 18 GHz ...................................................................................... 4 1.4 Radiated emissions measurement 18 - 26 GHz..................................................................................... 4 Project number: P000056040 006 Page 3 of 4 1 Test Setup Photos 1.1 Radiated emissions measurement 30 – 250 MHz 1.2 Radiated emissions measurement 250 – 1000 MHz Project number: P000056040 006 Page 4 of 4 1.3 Radiated emissions measurement 1 – 18 GHz 1.4 Radiated emissions measurement 18 - 26 GHz

Contact Information

Applicant

Gerrit de zwaan(Project Enineer)
[email protected]+31527253550Fax: +31527253550

Technical Contact

Zuidberg Frontline Systems B.V.Gerrit de zwaan
[email protected]31527253550

Buitenveld 5 · Ens · Netherlands

Non-Technical Contact

Zuidberg Frontline Systems B.V.Gerrit de zwaan
[email protected]31527253550

Test Firm

Kiwa Nederland B.V.Willem Jong
[email protected]+31 889983621

Technical Specifications

#Rule PartsFrequency RangePower Output
115B--
Confidentiality
Long Term
Grant Notes
included variants: Type Product description Trademark Type designation Variant PTO_CONTROLL ER_UNI_3-PINS Zuidberg 8002006 0 Variant PTO_CONTROLL ER_INT_4-PINS Zuidberg 8002007 0 Variant PTO_CONTROLL ER_UNI_8-PINS Zuidberg 8002008 0