FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Shenzhen Haoyiwei Electronic Co., Ltd./
  3. 2A73K-HYW22-3007

2A73K-HYW22-3007Intelligent Air Quality Detector

Shenzhen Haoyiwei Electronic Co., Ltd.
Intelligent Air Quality Detector - FCC ID 2A73K-HYW22-3007 - Shenzhen Haoyiwei Electronic Co., Ltd.
Click to zoom

Application Details

Equipment Class
DTS - Digital Transmission System
Date of Grant
Aug 13, 2022
Application Purpose
Original Equipment
Date of Application
Aug 11, 2022
Equipment Note
Intelligent Air Quality Detector
Frequency Range
2412.00000000 - 2462.00000000
Company
Shenzhen Haoyiwei Electronic Co., Ltd.
Country
China

Documents & Files

Select a file to view

Users Manual

↗

Cover Letter(s)

↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

GE22-3007a-PM2.5-PM10-CO2-HCHO-TVOC-temperature-humidity 7-in-one product specification Ver.: R3 A. major function  3 function keys: TOUCH keys [Touch], [POWER/LIGHT] and [Cycle];  4 digits display data;  IAQ air quality is GOOD, Moderate and POOR;  IAQ power supply sampling period is 5 seconds  PM2.5 display range of pm: 0-500ug/m;  PM10 display range: 0-500 ug/m;  TVOC display range: 0-9999 ug/m;  HCHO display range: 0-1230ug/m;  CO2 display range: 0-5000 ppm;  Indoor temperature detection range:-9°C ~ 50°C; Ambient humidity range: 20-99%  Temperature and humidity sampling period is 60 seconds.  Low electric indication; If there is one battery left, turn it off and prompt the user to charge.  Charging indication, charging icon flashes during charging;  Battery power supply, LED backlight delay for 30 seconds; B. Power-on & reset  When it is powered on or reset, the LCD is fully displayed for 3 seconds, and the backlight lights up for 30 seconds to start displaying data;  The accurate data needs to be turned on for 3 minutes before it can remain stable. C. Operation and display 1. Key function  3 function keys: TOUCH keys [Touch], [POWER/LIGHT] and [CYCLE] 【TOUCH】 【POWER/LIGHT】 【CYCLE】/ WIFI Singl e press Battery power illuminates backlight for 30S. 2.5-PM10-CO2-HCHO-TVOC data display switching Press to enable the light to stay on. Switch PM2.5-PM10-CO2-HCHO-TVOC data cycle display Press for 3 secon ds. --- Switch machine WIFI distribution network GE22-3007a-PM2.5-PM10-CO2-HCHO-TVOC-temperature-humidity 7-in-one product specification Ver.: R3 2. Key operation  Press the [TOUCH] button, the backlight will be lit for 30 seconds by battery power, and the PM2.5-PM10- CO2-HCHO-TVOC data display will be switched;  Press the [POWER/LIGHT] switch to enable the light to stay on; MARK is a light indicator icon.  Press [POWER/LIGHT] for a long time to switch on and OFF, and the shutdown will show off. Shut down after 1 second, shutdown interface diagram  Press [CYCLE] to display the cycle icon, and the data is displayed in cycle at PM2.5-PM10-CO2-HCHO- TVOC, with a cycle interval of 5 seconds. Press once to turn off the cycle display, and the default is the cycle mode, with the icon in red. GE22-3007a-PM2.5-PM10-CO2-HCHO-TVOC-temperature-humidity 7-in-one product specification Ver.: R3  Press and hold [Cycle] for 3 seconds to turn on or reset the WIFI network (it will not turn off), and the red WIFI symbol. D. Function and effect description 1. TVOC/CO2/PM2.5 data  CO2 1000ppm means that the air concentration of carbon dioxide reaches 1%  The detection of CO content in serum (plasma) is one of the indexes of metabolic acidity and alkalinity, which basically represents the situation of acid-alkali reserves in plasma. When the volume fraction of carbon dioxide in the air is 1%, I feel stuffy, dizzy and palpitation; 4%-5% feel dizzy; More than 6% will make people delirious, gradually stop breathing and cause death. The density of carbon dioxide is higher than that of air. When carbon dioxide is low, it is harmless to human body, but when it exceeds a certain amount, it will affect people's breathing (other organisms too). The reason is that the concentration of carbonic acid in blood increases, acidity increases, and acidosis occurs. 2. IAQ air quality grade  GOOD: when all five indicators are Good, the IAQ level is GOOD, and the LED lights are green.  Poor: When any of the five indicators is POOR, IAQ level is POOR, and the LED lights are red.  Moderate: others are Moderate, and the LED lights are yellow. 3. Temperature and humidity function:  Indoor temperature range: -9°C ~ 50°C, HH.H is displayed above 50°C, and LL. L is displayed below-9°C;  Indoor humidity range: 20-99%; More than 99% show HH and less than 20% show LL;  Indoor temperature detection period: 60 seconds. 4. The LED lighting backlight conditions:  Fire DC power supply, after power-on or RESET, LED highlights; Good Moderate Poor PM2.5 0-15 ug/m³ 15-40 ug/m³ >40 ug/m³ PM10 0-20 ug/m³ 20-100 ug/m³ >100 ug/m³ CO2 0~800ppm 800~1000ppm >1000ppm HCHO 0-30 ug/m³ 30-100 ug/m³ >100 ug/m³ TVOC 0-200 ug/m³ 200-600 ug/m³ >600 ug/m³ GE22-3007a-PM2.5-PM10-CO2-HCHO-TVOC-temperature-humidity 7-in-one product specification Ver.: R3  Dry battery power supply, power on or press [TOUCH] alone, the LED will highlight for 30 seconds, and then turn off. 5. Low electric indication  Low electric indication; If there is one battery left, turn it off and prompt the user to charge. E. accuracy. section of a normal route error section of a normal route error PM2.5 ug/m³ 0-100 ug/m³ ±20ug/m³ 101-500ug/m³ ±10-15% PM10 ug/m³ 0-100 ug/m³ ±25ug/m³ 101-500ug/m³ ±25% TVOC ug/m³ 0-200 ug/m³ ±20ug/m³ 200-600 ug/m³ ±25% HCHO ug/m³ 0-100 ug/m³ ±20ug/m³ 30-100 ug/m³ ±10% CO2 ppm 400~5000 ±5%+50ppm F. working parameter This product needs to always use the TYP.C data cable to maintain the power supply system, and the backup battery is only used for auxiliary power supply. The battery can only work continuously for about 3 hours. project unit MIN TYPE MAX operating voltage V 2.4 3.7-5.0 5.5 quiescent current uA -- 20 50 operational current mA -- 200 four hundred Working temperature °C -10 -- 50 G. FCC Statement: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and GE22-3007a-PM2.5-PM10-CO2-HCHO-TVOC-temperature-humidity 7-in-one product specification Ver.: R3 used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determine…

Text truncated - open the document above for the full version.

Cover Letter(s)

Shenzhen Haoyiwei Electronic Co., Ltd. Agent Authorization Company: Shenzhen Haoyiwei Electronic Co., Ltd. Address: 1101 Haoting Industrial Building, Shangcun, Gongming Street, Guangming District, Shenzhen Product Name: Intelligent Air Quality Detector Model Number(s): HYW22-3007 Product Description: Intelligent Air Quality Detector We authorize MiCOM Labs Inc., 575 Boulder Court, Pleasanton, California 94566, USA, to act on our behalf on all matters concerning the certification of above named equipment. We declare that MiCOM Labs Inc. is allowed to forward all information related to the approval and certification of equipment to the regulatory agencies as required and to discuss any issues concerning the approval application. Any and all acts carried out by MiCOM Labs on our behalf shall have the same effect as acts of our own. Signature: Date: Aug.08, 2022 Name: Miss Yang Title: Manager Company: Shenzhen Haoyiwei Electronic Co., Ltd.

Cover Letter(s)

Shenzhen Haoyiwei Electronic Co., Ltd. Date: August 9, 2022 Office of Engineering Technology Federal Communications Commission 7435 Oakland Mills Road Columbia, MD 21046 USA Subject; Request for Confidentiality FCC ID: 2A73K-HYW22-3007 To Whom It May Concern, Pursuant to the provisions of the Commission’s rules Title 47 Sections §0.457 and §0.459, we are requesting the Commission to withhold the following attachment(s) as confidential documents from public disclosure indefinitely. These documents contain detailed system and equipment descriptions and are considered as proprietary information in operation of the equipment. The public disclosure of these documents might be harmful to our company and would give competitors an unfair advantage in the market. Schematic Diagram Block Diagram Parts List Operational Description Software Security Requirements for UNII devices In additional to above mentioned documents, in order to comply with the marketing regulations in Title 47 CFR §2.803 and the importation rules in Title 47 CFR §2.1204, while ensuring that business sensitive information remains confidential until the actual marketing of newly authorized devices, we request Short Term Confidentiality of the following attachment(s); External Photos Test Setup Photos Internal Photos User Manual For 45 days, pursuant to Public Notice DA 04-1705. OR For 180 days pursuant to KDB 726920 D01. It is our understanding that all measurement test reports, FCC ID label format and correspondence during the certification review process cannot be granted as confidential documents and this information will be available for public review once the grant of equipment authorization is issued. Sincerely, Signature: Name: Miss Yang Title: Manager

External Photos

- Page 1 of 3 - Ext Photos - Page 2 of 3 - - Page 3 of 3 - ------END-----

ID Label/Location Info

Label location Label

Internal Photos

- Page 1 of 9 - Internal photos - Page 2 of 9 - - Page 3 of 9 - - Page 4 of 9 - - Page 5 of 9 - - Page 6 of 9 - - Page 7 of 9 - - Page 8 of 9 - - Page 9 of 9 - ------END----- WIFI ANT

RF Exposure Info

FCC ID: 2A73K-HYW22-3007 RF Exposure Evaluation Limits The criteria listed in the following table shall be used to evaluate the environment impact of human exposure to radio frequency (RF) radiation as specified in 1.1307(b) Limits for Maximum Permissible Exposure (MPE) Frequency range (MHz) Electric field strength (V/m) Magnetic field strength (A/m) Power density (mW/cm 2 ) Averaging time (minutes) (A) Limits for Occupational/Controlled Exposures 0.3–3.0 614 1.63 *(100) 6 3.0–30 1842/f 4.89/f *(900/f 2 ) 6 30–300 61.4 0.163 1.0 6 300–1500 f/300 6 1500–100,000 5 6 (B) Limits for General Population/Uncontrolled Exposure 0.3–1.34 614 1.63 *(100) 30 1.34–30 824/f 2.19/f *(180/f 2 ) 30 30–300 27.5 0.073 0.2 30 300–1500 f/1500 30 1500–100,000 1.0 30 f = frequency in MHz Friis transmission formula: Pd = (Pout*G)/(4*pi*r 2 ) Where Pd = power density in mW/cm 2 , Pout = output power to antenna in mW; G = gain of antenna in linear scale, Pi = 3.1416; R = distance between observation point and center of the radiator in cm Pd id the limit of MPE, 1 mW/cm 2 . If we know the maximum gain of the antenna and the total power input to the antenna, through the calculation, we will know the distance r where the MPE limit is reached. Test Procedure Software provided by client enabled the EUT to transmit and receive data at lowest, middle and highest channel individually. FCC ID: 2A73K-HYW22-3007 Test Result of RF Exposure Evaluation Antenna gain=0dBi For 2.4G WIFI mode: Mode Output power (dBm) Output power (mW) Numeric antenna gain Power Density at R=20cm (mW/cm 2 ) Limit (mW/cm 2 ) Result 802.11b 10.57 11.32 1 0.0023 1.0 PASS 802.11g 12.18 16.52 1 0.0033 1.0 PASS 802.11n(HT20) 11.07 12.81 1 0.0026 1.0 PASS 802.11n(HT40) 10.78 11.96 1 0.0024 1.0 PASS Then SAR evaluation is not require .

Test Report

Report No.: ET-22070599E Tel: +86 755 85259392 Email: [email protected] No.103, No.10, Phase I, Zone 3, Xinxing Industrial Park, Xinhe, Fuhai Street, Bao'an District, Shenzhen, Guangdong, China TEST REPORT Applicant: Shenzhen Haoyiwei Electronic Co., Ltd. Address of Applicant: 1101 Haoting Industrial Building, Shangcun, Gongming Street, Guangming District, Shenzhen Manufacturer/Factory: Shenzhen Haoyiwei Electronic Co., Ltd. Address of Manufacturer 1101 Haoting Industrial Building, Shangcun, Gongming Street, Guangming District, Shenzhen Product Name: Intelligent Air Quality Detector Model No.: HYW22-3007 Trade Mark: Haoyiwei FCC ID: 2A73K-HYW22-3007 Applicable standards: FCC CFR Title 47 Part 15 Subpart C Section 15.247 Date of Test: Jul.10, 2022- Aug.04, 2022 Date of report issued: Aug.05, 2022 Test Result : PASS * * In the configuration tested, the EUT complied with the standards specified above. Remark: The results shown in this test report refer only to the sample(s) tested , this test report cannot be reproduced, except in full without prior written permission of the company. The report would be invalid without specific stamp of test institute and the signatures of compiler and approver Prepared By Shenzhen ETR Standard Technology Co., Ltd. Address: No.103, No.10, Phase I, Zone 3, Xinxing Industrial Park, Xinhe, Fuhai Street, Bao'an District, Shenzhen, Guangdong, China Compiled by: Reviewed by: Approved by: Project Engineer Project Manager Authorized Signature - Page 2 of 52 - Report No.: ET-22070599E Report Revision History Report No. Description Issue Date ET-22070599E Original Aug.05, 2022 - Page 3 of 52 - Report No.: ET-22070599E Tel: +86 755 85259392 Email: [email protected] No.103, No.10, Phase I, Zone 3, Xinxing Industrial Park, Xinhe, Fuhai Street, Bao'an District, Shenzhen, Guangdong, China Contents Page 1. TEST SUMMARY ......................................................................................................................................4 2. GENERAL INFORMATION .......................................................................................................................5 3.1 GENERAL DESCRIPTION OF EUT .................................................................................................................5 3.2 TEST MODE ................................................................................................................................................7 3.3 DESCRIPTION OF SUPPORT UNITS ...............................................................................................................7 3.4 DEVIATION FROM STANDARDS .....................................................................................................................7 3.5 ABNORMALITIES FROM STANDARD CONDITIONS ...........................................................................................7 3.6 TEST FACILITY ............................................................................................................................................7 3.7 TEST LOCATION ..........................................................................................................................................7 ADDITIONAL INSTRUCTIONS ...............................................................................................................................7 3. TEST INSTRUMENTS LIST ......................................................................................................................8 4. TEST RESULTS AND MEASUREMENT DATA .......................................................................................9 5.1 ANTENNA REQUIREMENT .............................................................................................................................9 5.2 CONDUCTED EMISSIONS ...........................................................................................................................10 5.3 CONDUCTED PEAK OUTPUT POWER ..........................................................................................................13 5.4CHANNEL BANDWIDTH & 99% OCCUPY BANDWIDTH ...................................................................................15 5.5 POWER SPECTRAL DENSITY ......................................................................................................................19 5.6 BAND EDGES ............................................................................................................................................22 Conducted Emission Method ...................................................................................................................22 Radiated Emission Method ......................................................................................................................25 5.7 SPURIOUS EMISSION .................................................................................................................................30 Conducted Emission Method ...................................................................................................................30 Radiated Emission Method ......................................................................................................................35 5. TEST SETUP PHOTO .............................................................................................................................52 6. EUT CONSTRUCTIONAL DETAILS .......................................................................................................52 - Page 4 of 52 - Report No.: ET-22070599E Tel: +86 755 85259392 Email: [email protected] No.103, No.10, Phase I, Zone 3, Xinxing Industrial Park, Xinhe, Fuhai Street, Bao'an District, Shenzhen, Guangdong, China 1. Test Summary Test Item Section Result Test by Antenna requirement FCC part 15.203/15.247 (c) RSS-Gen §6.8 Pass / AC Power Line Conducted Emission FCC part 15.207 RSS-Gen §8.8 Pass Qiao Li Conducted Peak Output Power FCC part 15.247 (b)(3) RSS-247 §5.4.b Pass Yvan…

Text truncated - open the document above for the full version.

Test Setup Photos

ET-22070599 Page 1 of 2 Product Name: Intelligent Air Quality Detector Test Model No.: HYW22-3007 Test Setup Photo Radiated Emission ET-22070599 Page 2 of 2 Conducted Emission ------End------

Contact Information

Applicant

Miss Yang
[email protected]13682438717Fax: 13682438717

Technical Contact

Shenzhen Haoyiwei Electronic Co., Ltd.
[email protected]

China

Test Firm

Shenzhen ETR Standard Technology Co., Ltd.Smith Chen
[email protected]+86 755-85259392

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.41 GHz - 2.46 GHz16.50 mW
Confidentiality
Long Term
Grant Notes
Output power listed is conducted power. This device contains 20 and 40 MHz signal bandwidth. The antenna used with this transmitter must be installed to provide a minimum separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter, except in accordance with FCC multi- transmitter product procedures. End-users must be provided with operating procedures for satisfying RF exposure compliance.