FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Shenzhen Svakom Technology Co., Ltd/
  3. 2A74F-MW35

2A74F-MW35MW35

Shenzhen Svakom Technology Co., Ltd
MW35 - FCC ID 2A74F-MW35 - Shenzhen Svakom Technology Co., Ltd
Click to zoom

Application Details

Equipment Class
DTS - Digital Transmission System
Date of Grant
Jan 11, 2023
Application Purpose
Original Equipment
Date of Application
Jan 11, 2023
Equipment Note
MW35
Frequency Range
2402.00000000 - 2480.00000000
Company
Shenzhen Svakom Technology Co., Ltd
Country
China

Documents & Files

Select a file to view

Users Manual

↗

Cover Letter(s)

↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗

Test Setup Photos

↗
↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

 dŚŝƐĚĞǀŝĐĞĐŽŵƉůŝĞƐǁŝƚŚƉĂƌƚϭρŽĨƚŚĞ&ZƵůĞƐ͘KƉĞƌĂƚŝŽŶŝƐƐƵďũĞĐƚƚŽƚŚĞĨŽůůŽǁŝŶŐƚǁŽ ĐŽŶĚŝƚŝŽŶƐ͗;ϭͿƚŚŝƐĚĞǀŝĐĞŵĂLJŶŽƚĐĂƵƐĞŚĂƌŵĨƵůŝŶƚĞƌĨĞƌĞŶĐĞ͕ĂŶĚ;ϮͿƚŚŝƐĚĞǀŝĐĞŵƵƐƚĂĐĐĞƉƚ ĂŶLJŝŶƚĞƌĨĞƌĞŶĐĞƌĞĐĞŝǀĞĚ͕ŝŶĐůƵĚŝŶŐŝŶƚĞƌĨĞƌĞŶĐĞƚŚĂƚŵĂLJĐĂƵƐĞƵŶĚĞƐŝƌĞĚŽƉĞƌĂƚŝŽŶ͘ ŶLJĐŚĂŶŐĞƐŽƌŵŽĚŝĨŝĐĂƚŝŽŶƐŶŽƚĞdžƉƌĞƐƐůLJĂƉƉƌŽǀĞĚďLJƚŚĞƉĂƌƚLJƌĞƐƉŽŶƐŝďůĞĨŽƌ ĐŽŵƉůŝĂŶĐĞĐŽƵůĚǀŽŝĚƚŚĞƵƐĞƌΖƐĂƵƚŚŽƌŝƚLJƚŽŽƉĞƌĂƚĞƚŚĞĞƋƵŝƉŵĞŶƚ͘ EKd͗dŚŝƐĞƋƵŝƉŵĞŶƚŚĂƐďĞĞŶƚĞƐƚĞĚĂŶĚĨŽƵŶĚƚŽĐŽŵƉůLJǁŝƚŚƚŚĞůŝŵŝƚƐĨŽƌĂůĂƐƐĚŝŐŝƚĂů ĚĞǀŝĐĞ͕ƉƵƌƐƵĂŶƚƚŽWĂƌƚϭρŽĨƚŚĞ&ZƵůĞƐ͘dŚĞƐĞůŝŵŝƚƐĂƌĞĚĞƐŝŐŶĞĚƚŽƉƌŽǀŝĚĞƌĞĂƐŽŶĂďůĞ ƉƌŽƚĞĐƚŝŽŶĂŐĂŝŶƐƚŚĂƌŵĨƵůŝŶƚĞƌĨĞƌĞŶĐĞŝŶĂƌĞƐŝĚĞŶƚŝĂůŝŶƐƚĂůůĂƚŝŽŶ͘dŚŝƐĞƋƵŝƉŵĞŶƚŐĞŶĞƌĂƚĞƐ͕ ƵƐĞƐĂŶĚĐĂŶƌĂĚŝĂƚĞƌĂĚŝŽĨƌĞƋƵĞŶĐLJĞŶĞƌŐLJĂŶĚ͕ŝĨŶŽƚŝŶƐƚĂůůĞĚĂŶĚƵƐĞĚŝŶĂĐĐŽƌĚĂŶĐĞǁŝƚŚ ƚŚĞŝŶƐƚƌƵĐƚŝŽŶƐ͕ŵĂLJĐĂƵƐĞŚĂƌŵĨƵůŝŶƚĞƌĨĞƌĞŶĐĞƚŽƌĂĚŝŽĐŽŵŵƵŶŝĐĂƚŝŽŶƐ͘,ŽǁĞǀĞƌ͕ƚŚĞƌĞŝƐ ŶŽŐƵĂƌĂŶƚĞĞƚŚĂƚŝŶƚĞƌĨĞƌĞŶĐĞǁŝůůŶŽƚŽĐĐƵƌŝŶĂƉĂƌƚŝĐƵůĂƌŝŶƐƚĂůůĂƚŝŽŶ͘ /ĨƚŚŝƐĞƋƵŝƉŵĞŶƚĚŽĞƐĐĂƵƐĞŚĂƌŵĨƵůŝŶƚĞƌĨĞƌĞŶĐĞƚŽƌĂĚŝŽŽƌƚĞůĞǀŝƐŝŽŶƌĞĐĞƉƚŝŽŶ͕ ǁŚŝĐŚĐĂŶďĞĚĞƚĞƌŵŝŶĞĚďLJƚƵƌŶŝŶŐƚŚĞĞƋƵŝƉŵĞŶƚŽĨĨĂŶĚŽŶ͕ƚŚĞƵƐĞƌŝƐĞŶĐŽƵƌĂŐĞĚƚŽƚƌLJ ƚŽĐŽƌƌĞĐƚƚŚĞŝŶƚĞƌĨĞƌĞŶĐĞďLJŽŶĞŽƌŵŽƌĞŽĨƚŚĞĨŽůůŽǁŝŶŐŵĞĂƐƵƌĞƐ͗ ͲͲZĞŽƌŝĞŶƚŽƌƌĞůŽĐĂƚĞƚŚĞƌĞĐĞŝǀŝŶŐĂŶƚĞŶŶĂ͘ ͲͲ/ŶĐƌĞĂƐĞƚŚĞƐĞƉĂƌĂƚŝŽŶďĞƚǁĞĞŶƚŚĞĞƋƵŝƉŵĞŶƚĂŶĚƌĞĐĞŝǀĞƌ͘ ͲͲŽŶŶĞĐƚƚŚĞĞƋƵŝƉŵĞŶƚŝŶƚŽĂŶŽƵƚůĞƚŽŶĂĐŝƌĐƵŝƚĚŝĨĨĞƌĞŶƚ ĨƌŽŵƚŚĂƚƚŽǁŚŝĐŚƚŚĞƌĞĐĞŝǀĞƌŝƐĐŽŶŶĞĐƚĞĚ͘ ͲͲŽŶƐƵůƚƚŚĞĚĞĂůĞƌŽƌĂŶĞdžƉĞƌŝĞŶĐĞĚƌĂĚŝŽͬdsƚĞĐŚŶŝĐŝĂŶĨŽƌŚĞůƉ͘ dŚĞĚĞǀŝĐĞŚĂƐďĞĞŶĞǀĂůƵĂƚĞĚƚŽŵĞĞƚŐĞŶĞƌĂůZ&ĞdžƉŽƐƵƌĞƌĞƋƵŝƌĞŵĞŶƚ͘dŚĞĚĞǀŝĐĞĐĂŶďĞ ƵƐĞĚŝŶƉŽƌƚĂďůĞĞdžƉŽƐƵƌĞĐŽŶĚŝƚŝŽŶǁŝƚŚŽƵƚƌĞƐƚƌŝĐƚŝŽŶ

Cover Letter(s)

Shenzhen Svakom Technology Co., Ltd (2023.01.06) Eurofins Electrical and Electronic Testing NA, Inc. 914 West Patapsco Avenue Baltimore, MD 21230 RE: CONFIDENTIALITY REQUEST FOR (MW35 / MW35 / FCC ID: 2A74F-MW35) To Whom It May Concern: This letter serves as an official request for confidentiality under sections 0.457 and 0.459 of CFR 47. We have requested that the Exhibits Long-Term Confidentiality Short-Term Confidentiality NOTE 2 ID Label/Location No No Attestation Statement No No External Photos No ☐ Block Diagram ☒ ☐ Schematics ☒ ☐ Test Report No No Test Setup Photos No ☐ User’s Manual ☐ NOTE 1 ☐ Internal Photos ☐ NOTE 1 ☐ Parts List / Tune Up ☐ ☐ RF Exposure Info No No Operational Description ☒ ☐ Cover Letter(s) No No SDR Software / Security Info ☐ No required to be submitted with this application be permanently withheld from public review. Above mentioned document contains detailed system and equipment description are considered as proprietary information in operation of the equipment. The public disclosure of above documents might be harmful to our company and would give competitor an unfair advantage in the market. Please contact me if there is any information you may need. Sincerely, Signature: Name: Ethan Yang Title: General manager

Cover Letter(s)

Shenzhen Svakom Technology Co., Ltd (2023.01.06) Eurofins Electrical and Electronic Testing NA, Inc. 914 West Patapsco Avenue Baltimore, MD 21230 RE: LETTER OF AGENT AUTHORIZATION To Whom It May Concern: We, the undersigned, hereby authorize (Shenzhen CTB Testing Technology Co., Ltd.) to act on our behalf in all matters relating to application for equipment authorization, including the signing of all documents relating to these matters. We also hereby certify that no party to the application authorized hereunder is subject to the denial of benefits, including FCC benefits, pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C.853(a). This agreement expires one year from the current date. Sincerely, Signature: Name: Ethan Yang Title: General manager

External Photos

External Photos

ID Label/Location Info

FCC ID LABEL: Label Location: FCC ID: 2A74F-MW35 Model No.: MW35 This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) This device must accept any interference received, including interference that may cause undesired operation.

Internal Photos

Internal Photos ANT

RF Exposure Info

Shenzhen CTB Testing Co., Ltd. FCC ID: 2A74F-MW35 Portable device According to §15.247(e)(i) and §1.1307(b)(1), systems operating under the provisions of this section shall be operated in a manner that ensures that the public is not exposed to radio frequency energy level in excess of the Commission’s guidelines. According to KDB447498 D01 General RF Exposure Guidance V06 The 1-g SAR and 10-g SAR test exclusion thresholds for 100 MHz to 6 GHz at test separation distances ≤ 50 mm are determined by: [(max. power of channel, including tune-up tolerance, mW)/(min. test separation distance, mm)]·[√f(GHZ)] ≤ 3.0 for 1-g SAR and ≤ 7.5 for 10-g extremity SAR, where: • f(GHZ) is the RF channel transmit frequency in GHz • Power and distance are rounded to the nearest mW and mm before calculation • The result is rounded to one decimal place for comparison When the minimum test separation distance is < 5 mm, a distance of 5 mm is applied to determine SAR test exclusion. BLE: Modulation Channel Freq. (GHz) Conduct ed power (dBm) Conducte d power (mW) Tune-up power (dBm) Max tune-up power (dBm) Max tune-up power (mW) Distance (mm) Result calculatio n SAR Exclusion threshold SAR test exclusion 2.402 -0.427 0.91 0±1 1.00 1.26 <5 0.39023 3.00 YES 2.44 -0.827 0.83 0±1 1.00 1.26 <5 0.39330 3.00 YES 2.480 -0.801 0.83 0±1 1.00 1.26 <5 0.39651 3.00 YES GFSK Conclusion: For the max result : 0.39651≤ FCC Limit 3.0 for 1g SAR.

Test Report

ReportNo.:RFI-LAB-RF-202301-AA06 QP030-E41 Page1of9 TestingReport CustomerName:ShenzhenSvakomTechnologyCo.,Ltd ProductName:MW35 SampleModel:MW35 ReferenceStandard:GB/T9410-2008;ANSI/IEEEStd149-2021 IssueDate:2023.01.09 Engineer:Date: Auditor:Date: Approver:Date: ReportNo.:RFI-LAB-RF-202301-AA06 QP030-E41 Page2of9 Version VersionNo.DateDescriptionFormulateApproval A02023.01.09Forthefirsttime,formulateJacksonEason Contents 1.GeneralInformation.........................................................................................................................3 1.1Generalinformationoftestinginstitutions...........................................................................3 1.2Testingprinciple...................................................................................................................3 1.3Testequipment......................................................................................................................4 1.4Testenvironment...................................................................................................................4 1.5Statement..............................................................................................................................4 2.SampleInformation.........................................................................................................................5 2.1Clientinformation.................................................................................................................5 2.2DescriptionofEUT(S)..........................................................................................................5 2.3EUTappearance....................................................................................................................6 2.4EUTsetupphotooffreespaceOTAtesting.........................................................................6 3.TestResults......................................................................................................................................7 3.1Teststandard.........................................................................................................................7 3.2Testuncertainty.....................................................................................................................7 3.3Testdata................................................................................................................................7 3.3.1Typicalfreespaceefficiencyandgain......................................................................7 3.3.2Typicalfreespaceradiationpattern...........................................................................8 (Thefollowingisblank)................................................................................................................9 ReportNo.:RFI-LAB-RF-202301-AA06 QP030-E41 Page3of9 1.GeneralInformation 1.1Generalinformationoftestinginstitutions Name ShenzhenRFI-LABCommunicationTechnologyCo.,Ltd. Address 10/FA,LingyunBld,LiufangRd,BaoanDistrict,SZ Tel 13682621346 E-mail [email protected] Equipment AlltheequipmentusedinthereportisfixedinZoneB,WestSideof1/F,Building1, TingweiIndustrialPark,No.6LiufangRoad,Bao'anDistrict,Shenzhen 1.2Testingprinciple ReportNo.:RFI-LAB-RF-202301-AA06 QP030-E41 Page4of9 1.3Testequipment EquipmentModelNo.SerialNo.Manufacturer Calibration date Next calibration date OTATest System RayZone-5000 RFI-LAB-RF -D00 GTS2021.3.152023.3.14 Network Analyzer E5071C RFI-LAB-RF -D01 KEYSIGHT2022.5.132023.5.12 1.4Testenvironment Temperature 23.8°C Humidity 59%RH Pressure 100.20kPa 1.5Statement (1)Thetestresultsinthereportareonlyapplicabletothetestedsamplesandthetestedsamples workundertheenvironmentdescribedinthereport. (2)OnlyShenzhenRFI-LABCommunicationTechnologyCo.,Ltd.havetherighttomodifythe report,andthemodificationinformationshallbeannotatedintherevisionform. (3)Anyobjectiontothisreportshallberaisedwithin30daysafterformalconfirmationofthe report. (4)Thisreportisinvalidifthereisanyevidencethatthesampleinformationprovidedisfalsified. (5)Thereportisinvalidwithoutthesignatureoftheauditorandapprover. ReportNo.:RFI-LAB-RF-202301-AA06 QP030-E41 Page5of9 2.SampleInformation 2.1Clientinformation Name ShenzhenSvakomTechnologyCo.,Ltd Address ZoneB,2ndfloor,buildingh,gangzhilongbusinesscenter,Qinglong Road,Longhuastreet,LonghuaNewDistrict,Shenzhen Contacts / Tel / E-mail / Manufacturer DongguanQianheElectronicTechnologyCo.,Ltd. 2.2DescriptionofEUT(S) ProductName MW35 SampleModel MW35 AntennaSize / SerialNo. / TestItem Antennagain;Efficiency;Radiationpattern FrequencyRange 2400-2500MHz ReceivedDate 2023.01.06 TestDate 2023.01.09 Remark ThelengthoftheRFcableis60mm ReportNo.:RFI-LAB-RF-202301-AA06 QP030-E41 Page6of9 2.3EUTappearance 2.4EUTsetupphotooffreespaceOTAtesting Planform Frontview ReportNo.:RFI-LAB-RF-202301-AA06 QP030-E41 Page7of9 3.TestResults 3.1Teststandard NameParameterMethodStandardno. Mobile communication antenna Antennagain Genericspecification forantennasusedinthe mobilecommunications GB/T 9410-2008 Radiationpattern Antenna Radiationefficiency IEEEStandardTest ProceduresforAntennas ANSI/IEEEStd 149-2021 Gainanddirectivity 3.2Testuncertainty TheuncertaintywascalculatedonthebasisoftheGUMpublishedbyISO,usingthe inclusionfactorofK=2andthe95%confidenceleveltoexpresstheextended uncertainty. ItemUncertainty Antennagain±0.72dB Radiationefficiency±0.72dB 3.3Testdata 3.3.1Typicalfreespaceefficiencyandgain Frequency/MHz 24002410242024302440245024602470248024902500 PeakGain/dBi -2.84-2.97-3.09-3.04-3.05-3.11-3.26-3.50-3.57-3.76-3.88 Efficiency/% 18.8818.2117.3717.1616.9316.4816.0115.7415.3014.6714.04 ReportNo.:RFI-LAB-RF-202301-AA06 QP030-E41 Page8of9 3.3.2Typicalfreespaceradiationpattern (1)X-ZPlane: (2)Y-ZPlane: ReportNo.:RFI-LAB-RF-202301-AA06 QP030-E41 Page9of9 (3)X-YPlane: (4)TypicalFreeSpace3DRadiationPatternat2.45GHz: -------------------------------------------------End------------------------------------------------ (Thefollowingisblank)

Test Setup Photos

Shenzhen CTB Testing Technology Co., Ltd. Report No.: CTB221227031RF Report Tel: 4008-707-283 Web: http://www.ctb-lab.net Page 1 of 35 TEST REPORT Compiled by: Reviewed by: Approved by: Chen Zheng Arron Liu Bin Mei / Director Note: If there is any objection to the inspection results in this report, please submit a written report to the company within 15 days from the date of receiving the report. The test report is effective only with both signature and specialized stamp. This result(s) shown in this report refer only to the sample(s) tested. Without written approval of Shenzhen CTB Testing Technology Co., Ltd. this report can’t be reproduced except in full. The tested sample(s) and the sample information are provided by the client. “*” indicates the testing items were fulfilled by subcontracted lab. “#” indicates the items are not in CNAS accreditation scope. Product Name: MW35 FCC ID: 2A74F-MW35 Trademark: SVAKOM Model Number: MW35 Prepared For: Shenzhen Svakom Technology Co., Ltd Address: Zone B, 2nd floor, building h, gangzhilong business center, Qinglong Road, Longhua street, Longhua New District, Shenzhen Manufacturer: Dongguan Qianhe Electronic Technology Co., Ltd. Address: Building 3, No.3, Chang'an Fengsheng Road, Chang'an Town, Dongguan, Guangdong, China Prepared By: Shenzhen CTB Testing Technology Co., Ltd. Address: 1&2/F., Building A, No.26, Xinhe Road, Xinqiao, Xinqiao Street, Bao'an District, Shenzhen, Guangdong, China Sample Received Date: Dec. 26, 2022 Sample tested Date: Dec. 26, 2022 to Dec. 28, 2022 Issue Date: Dec. 28, 2022 Report No.: CTB221227031RF Test Standards FCC Part15.247 ANSI C63.10:2013 Test Results PASS Remark: This is Bluetooth radio test report. Shenzhen CTB Testing Technology Co., Ltd. Report No.: CTB221227031RF Report Tel: 4008-707-283 Web: http://www.ctb-lab.net Page 2 of 35 TABLE OF CONTENT Test Report Declaration Page 1. VERSION ........................................................................................................................................ 3 2. TEST SUMMARY ........................................................................................................................... 4 3. MEASUREMENT UNCERTAINTY ................................................................................................. 5 4. PRODUCT INFORMATION AND TEST SETUP ............................................................................ 6 4.1 Product Information .......................................................................................................................... 6 4.2 Test Setup Configuration .................................................................................................................. 6 4.3 Support Equipment........................................................................................................................... 6 4.4 Channel List ..................................................................................................................................... 7 4.5 Test Mode ........................................................................................................................................ 7 4.6 Test Environment ............................................................................................................................. 7 5. TEST FACILITY AND TEST INSTRUMENT USED ....................................................................... 8 5.1 Test Facility ...................................................................................................................................... 8 5.2 Test Instrument Used ....................................................................................................................... 8 6. AC POWER LINE CONDUCTED EMISSION ................................................................................ 10 6.1 Block Diagram Of Test Setup ......................................................................................................... 10 6.2 Limit ................................................................................................................................................ 10 6.3 Test procedure ............................................................................................................................... 10 6.4 Test Result ..................................................................................................................................... 12 7. RADIATED SPURIOUS EMISSION ............................................................................................. 14 7.1 Block Diagram Of Test Setup ......................................................................................................... 14 7.2 Limit ................................................................................................................................................ 14 7.3 Test procedure ............................................................................................................................... 15 7.4 Test Result ..................................................................................................................................... 16 8. BAND EDGE AND RF COUNDUCTED SPURIOUS EMISSIONS ............................................... 23 8.1 Block Diagram Of Test Setup ......................................................................................................... 23 8.2 Limit ................................................................................................................................................ 23 8.3 Test procedure ............................................................................................................................... 23 8.4 Test Result ..................................................................................................................................... 24 9. COUDUCTED OUTPUT POWER .................................................................................…

Text truncated - open the document above for the full version.

Test Setup Photos

Radiated Emission Below 1G Above 1G Conducted emissions

Contact Information

Applicant

Yang Ethan
[email protected]13538218145Fax: 13266861229

Technical Contact

Shenzhen Svakom Technology Co., LtdEthan Yang
[email protected]13538218145

Zone B, 2nd floor, building h, gangzhilong · Shenzhen, Guangdong · China

Test Firm

Shenzhen CTB Testing Technology Co., Ltd.Rita Xiao
[email protected]86-13538218145

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.40 GHz - 2.48 GHz910.00 µW
Confidentiality
Long Term
Grant Notes
Output power listed is conducted.

Other Applications from Shenzhen Svakom Technology Co., Ltd

Emma Neo 2 - FCC ID 2A74F-SA299A - Shenzhen Svakom Technology Co., Ltd
2A74F-SA299A

Emma Neo 2

Oct 07, 2024

Equipment Class

DTS - Digital Transmission System
ELMER - FCC ID 2A74F-SCB02B - Shenzhen Svakom Technology Co., Ltd
2A74F-SCB02B

ELMER

Sep 28, 2024

Equipment Class

DSC - Part 15 Security/Remote Control Transmitter
Sam Neo 2 - FCC ID 2A74F-S08P - Shenzhen Svakom Technology Co., Ltd
2A74F-S08P

Sam Neo 2

Jul 02, 2024

Equipment Class

DTS - Digital Transmission System
Sam Neo 2 Pro - FCC ID 2A74F-S08PRO - Shenzhen Svakom Technology Co., Ltd
2A74F-S08PRO

Sam Neo 2 Pro

Jul 02, 2024

Equipment Class

DTS - Digital Transmission System
Trysta Neo - FCC ID 2A74F-SA374A - Shenzhen Svakom Technology Co., Ltd
2A74F-SA374A

Trysta Neo

Apr 16, 2024

Equipment Class

DTS - Digital Transmission System