FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Guangzhou Weijunda Network Technology Co., Ltd./
  3. 2A75Q-TA3000

2A75Q-TA3000TA3000 WirelessGaming headset

Guangzhou Weijunda Network Technology Co., Ltd.
TA3000 WirelessGaming headset - FCC ID 2A75Q-TA3000 - Guangzhou Weijunda Network Technology Co., Ltd.
Click to zoom

Application Details

Equipment Class
DSS - Part 15 Spread Spectrum Transmitter
Date of Grant
Jul 16, 2023
Application Purpose
Original Equipment
Date of Application
Jul 16, 2023
Equipment Note
TA3000 WirelessGaming headset
Frequency Range
2402.00000000 - 2480.00000000
Company
Guangzhou Weijunda Network Technology Co., Ltd.
Country
China

Documents & Files

Select a file to view

Users Manual

↗

Attestation Statements

↗
↗
↗

Cover Letter(s)

↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗
↗
↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

_ 一 WolflawS TA3000 wireless gaming headset, equipped with a 50mm high precision neodymium drivers and soft leatherette ear cups, which offers a particularly immersive sound quality, delivers you an extreme gaming experience and greatly highlight your gaming atmosphere. Born for every FPS! With the USB connection, it could be perfectly compatible with PC/ Laptop, PS4, Mac and other devices with USB port. Extra 3.5mm cable and bluetooth function offer you more possibilities!! WalfLawS 一心 To prevent possible hearing damage, do not listen at high volume levels for long periods. W咄LilYlf; USER MANUAL 二TA3000 Wireless Gaming Headset _ I ntrod u ct 1 on -------------------------------------------------------1 Pro d uct O v er v1 e w -------------------------------------------------1 Hea d set Po w er/Mic Button ---------- ---------- ---------- --------- 2 Hea d set Char g in g -------------------------------------------------3 Hea d set Connection ----------- ----------- ----------- ----------- - 4 - 5 O peratin g Instruct ion ------------- ---------- ------------ --------- 6 Techn ic al Speci f ic a tions ---------- ---------- ---------- --------- --- 7 T rou bles hootin g Tip s ----------- ----------- ----------- -------- -- - 8 Safet y a n d Prec a utions ---------- ---------- ---------- ---------- -- 9 Co mpa tibilit y In f or ma tion --------------------------------------- 1 0 6 · - ---- ---- 、、、 、 r·v. 、 、 9 .. .... .... ...... . - - · ©Power Button @ BT/2.4G Mode @ volume+ ®Volume­ ®Mic On/Off ®3.SmmPort 0 Charge Port ®Detachable Mic (!) Headset Power Button A. Power On/Off: Hold down the power button for 3 seconds until you hear a indicating voice FF 。 I ffn oo . ) 二 & 勹 J , l © \, 贮 I Click the Button . .. ............ . . . . . . . .. - -i - - - - . . . . . . . mode or bluetooth mode. 急Mic Mute Button @ ` ClkkOn<e , ClkkOnce Mk On MkOff 。@ 一 - _ _ 1. It is recommended to fully charge the headset before first use. 2. When the headset remaining the battery level is low, you will hear a'battery low'on your headset. 3. Connect the Type-C cable to the charging port on the headset, and plug the other end into any USB power source. 米,E , 夕 、 - t 三 丿F � 它$竺点'J:总�':J它 """''" @ 。 PS4 2.4G Wireless Adapter (Included) ,f'� —,,,, ® ------ � � J 三二 二 ----! PC PS4/PS5 notebook � ------ e> 厂 — 巴 ;;. : : 一 二 � ------ - 5 � � : 丿 J 3.5mmjack XBOX ONE/ S Nin t endo Mobile (Included) I 3.SmmJ"k ® 。 � 咕芦;:::·;芯芦,;: "''''New v,,.10, Xbo, o,, To use the wireless headset on your device (PC, PS4, PSS, laptop, Mac,XBOX ONE,Nintendo,Mobile) : 1. Connect the wireless adapter(included) to a USB port on your device ((PC, PS4, PSS, laptop). 2. Plug the 3.5mm audio cable (included) into the headset, then connect your device (XBOX ONE/S, Nintendo,Mobile). 3. Press the power button on the headset for 3 seconds to power on. 4. When the headset ear cup LED is solid, the headset is connected. * Note: If it is your first time using the headset, you may need to set the headset as the default input and output device. 1. Plug the 2.4G Wireless Adapter into the Gamepad. 2. Shake PS4 joystick to enter the System Settings. 3. Choose "Devices", next choose "Audio Devices", and then choose "Output Device",and choose "USB Headset", right-dick on'Output to Headphones'and select "All Audio", adjust the 'volume control (headphones)'. 4. Confirm that each plug is inserted firmly and fully. _ 1. Plug the 3.5mm cable(included) into the headset, and you could connect the headset to the Second Generation Xbox One Controllers directly. 2. While connecting to the old version Xbox One Controller, you need an extra adapter(Not Included) CD . Plug the 3.5mm cable into the headset. @. Plug the adapter into the Xbox one Controller. @ . Connect the headset to the 3.5mm port of the adapter. 3. Adjust or rotate the 3.5mm interface until both sides of the headphones have smooth sound. @ _ _ _ - Please Connect the Microsoft Adapter (Not Included) with the 3 • 5mm jack for this headset towork on an old version Xbox One/ Xbox One S controller Information for Xbox One User Controller has a headset port Headset Adapter Not Required 勹 二 二 � Wo六sstraight out of the box Controller has no headset port Microsoft Stereo Headset Adapter Required 气Mier::�笠1��pter (not included) _ Driver Diameter: 50mm Battery Capacity: 900mAh Dimension: 185*75*195mm Weight: 263g Charging Time: 2.5 hours Duration Time: e!'45 hours Charge Interface: Ty pe-C No sound/low sound 二 芷 了 = 咒 :: 芯 它 : : : : 。 它 芯 . . .., App Problem I Close the active App and re-open it alternatively Loose Connector Confirm that each plug is inserted Microphone not working Possible Cause I Solution Mic Button Checkthemicone-keymutebuttonontheheadsetisoff. Chat Volume Loose Connector Press the Chat Button on the Chat/Came Mix of the Ear Force Headset Audio Controller. Confirm that each plug is inserted firmly and fully. Voice interrupted Possible cause Setting Weak Signal Check the default (input and output) sound device is selected for this headset. Check the network. * Any further question, please feel free to contact us though Amazon or email us via: [email protected], and we are here to serve you all the time. ·Observe all warnings, precautions and instructions. ·CHOKING HAZARD-Contains small parts. Keep out of the reach of small children. ·Stop using the system immediately if you begin to feel tired or if you experience discomfort or pain in your head while operating the wireless stereo headset. If the condition persists, consulta doctor. ·Avoid prolonged use of the wireless stereo headset. Take a break at about 15-minute intervals. ·Permanent hearing loss may occur if the headset is used at high volume. Set the volume to a safe level. Overtime , increasingly loud audio may start to sound normal but can actually be damaged to your hearing. If you experience ringing in your ears or muffled speech, stop listening and have your hearing checked. The louder the volume, the sooner your hearing could be a…

Text truncated - open the document above for the full version.

Attestation Statements

Guangzhou Weijunda Network Technology Co., Ltd. The information provided in this letter is based on the referenced rule parts of Title 47 of the CFR as well as KDB 986446 D01. An expiration date for this letter does not exist. In case the U.S. agent changes, the grantee is obligated to notify the FCC. Federal Communications Commission Authorization and Evaluation Division Equipment Authorization Branch 7435 Oakland Mills Road Columbia, MD 21046 07/14/2023 U.S. Agent Designation [Guangzhou Weijunda Network Technology Co., Ltd.] acknowledges their consent for the following contact located in the United States to act as their agent for service of process for the equipment for which authorization is sought (FCC ID: 2A75Q-TA3000): Name of U.S. agent contact person: Tim Payne Company U.S. agent: FCC US Agent, LLC Physical U.S. address of agent: 3722 Illinois Avenue, Saint Charles, IL, 60174, USA FRN of U.S. agent: 0033402884 Email address of U.S. agent: [email protected] Phone of U.S. agent: 708-571-3148 FCC US Agent, LLC acknowledges their obligation to accept service of process on behalf of [Guangzhou Weijunda Network Technology Co., Ltd.]. [Guangzhou Weijunda Network Technology Co., Ltd.] accepts its obligation to maintain an agent for service of process in the United States for no less than one year after either the grantee has permanently terminated all marketing and importation of the applicable equipment within the U.S., or the conclusion of any Commission-related administrative or judicial proceeding involving the equipment, whichever is later. By signing this form, we confirm the above and that we are aware of the application requirements listed under § 2.911(d)(7). Sincerely, Signature Qi Zhou Zi Product Manager Guangzhou Weijunda Network Technology Co., Ltd. Signature Tim Payne Manager FCC US Agent, LLC 48_[model] US_Agent_2.911(d)(7) - U, V03

Attestation Statements

Covered Equipment Identification Letter For Certification Service in the USA Federal Communication Commission Equipment Authorization Division, Application Processing Branch 7435 Oakland Mills Road Columbia, MD 21048 To whom it may concern Pursuant to Section 2.911(d)(5)(ii) of the Commission’s Rules (47 C.F.R.) we attest as follows: We, applicant Company Name: Guangzhou Weijunda Network Technology Co., Ltd. Address: No. 35, Lixiang Road,Licheng street, Zengcheng District, Guangzhou, China Phone: 13538218145 certify that, as of the date of the filing of the application, the applicant is not identified on the Covered List as an entity producing “covered” equipment. If you have any questions, please feel free to contact us at the address shown below. Sincerely, Signature Date:2023-07-14 Printed Name of Signee: Qi Zhou Zi Company: Guangzhou Weijunda Network Technology Co., Ltd. Address: No. 35, Lixiang Road,Licheng street, Zengcheng District, Guangzhou, China Phone: 13538218145 Fax: 13266861229 Email: [email protected]

Attestation Statements

Covered Equipment Attestation Letter For Certification Service in the USA Federal Communication Commission Equipment Authorization Division, Application Processing Branch 7435 Oakland Mills Road Columbia, MD 21048 To whom it may concern Pursuant to Section 2.911(d)(5)(i)-(ii) of the Commission’s Rules (47 C.F.R.) we attest as follows for the product listed below: FCC ID Model name 2A75Q-TA3000 TA3000 We, applicant Company Name: Guangzhou Weijunda Network Technology Co., Ltd. Address: No. 35, Lixiang Road,Licheng street, Zengcheng District, Guangzhou, China Phone: 13538218145 certify that the equipment for which authorization is sought is not “covered” equipment prohibited from receiving an equipment authorization pursuant to section 2.903 of the FCC rules. If you have any questions, please feel free to contact us at the address shown below. Sincerely, Signature Date:2023-07-14 Printed Name of Signee: Qi Zhou Zi Company: Guangzhou Weijunda Network Technology Co., Ltd. Address: No. 35, Lixiang Road,Licheng street, Zengcheng District, Guangzhou, China Phone: 13538218145 Fax: 13266861229 Email: [email protected]

Cover Letter(s)

Confidentiality Request Letter For Certification Service in the USA Federal Communication Commission Equipment Authorization Division, Application Processing Branch 7435 Oakland Mills Road Columbia, MD 21048 To whom it may concern Pursuant to Paragraphs §0.457 and 0.459 of the Commission’s Rules (47 C.F.R.) and Section §552(b)(4) of the Freedom of Information Act, we request confidentiality for the documentation of the following products: FCC ID Model name 2A75Q-TA3000 TA3000 For the products listed above, we request permanent confidentiality for all applicable exhibits as there are:  the Operational Description  the Block Diagram  the Schematics The above listed exhibits contain trade secrets and proprietary information that could be of benefit to our competitors. If you have any questions, please feel free to contact us at the address shown below. Sincerely, Signature Date:2023-07-14 Printed Name of Signee: Qi Zhou Zi Company: Guangzhou Weijunda Network Technology Co., Ltd. Address: No. 35, Lixiang Road,Licheng street, Zengcheng District, Guangzhou, China Phone: 13538218145 Fax: 13266861229 Email: [email protected]

External Photos

Page 1 of 4 FCC ID:2A75Q-TA3000 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity External Photos of the EUT Fig. 1 Fig. 2 Page 2 of 4 FCC ID:2A75Q-TA3000 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Fig. 3 Fig. 4 Page 3 of 4 FCC ID:2A75Q-TA3000 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Fig. 5 Fig. 6 Page 4 of 4 FCC ID:2A75Q-TA3000 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Fig. 7 Fig. 8

ID Label/Location Info

Page 1 of 1 FCC ID:2A75Q-TA3000 _____________________________________________________________________________________________________ This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.. Page 1 of 1 LABEL AND LOCATION (Size: L 4.0cm x W 2.0cm) Label Location TA3000 WirelessGaming headset Model: TA3000 FCC ID:2A75Q-TA3000

Internal Photos

Page 1 of 4 FCC ID:2A75Q-TA3000 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Internal Photos of the EUT Fig. 1 Fig. 2 Page 2 of 4 FCC ID:2A75Q-TA3000 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Fig. 3 Fig. 4 Page 3 of 4 FCC ID:2A75Q-TA3000 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Fig. 5 Fig. 6 Antenna Page 4 of 4 FCC ID:2A75Q-TA3000 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Fig. 7 Fig. 8

RF Exposure Info

Page 1 of 4 FCC ID:2A75Q-TA3000 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity FCC RF Exposure Evaluation 1. Product Information FCC ID : 2A75Q-TA3000 Product name : TA3000 WirelessGaming headset Test Model : TA3000 Power Supply : Input: DC 5V DC 3.7V by Rechargeable Li-ion Battery, 900mAh Hardware Version : V4.0 Software Version : V142 Frequency Range : 2402MHz ~ 2480MHz Channel Number : 79 channels for Bluetooth V5.2 (DSS) 40 channels for Bluetooth V5.2 (DTS) Channel Spacing : 1MHz for Bluetooth V5.2 (DSS) 2MHz for Bluetooth V5.2 (DTS) Modulation Type : GFSK, π/4-DQPSK, 8-DPSK for Bluetooth V5.2 (DSS) GFSK for Bluetooth V5.2 (DTS) Bluetooth Version : V5.2 Antenna Type : PCB Antenna Antenna Gain : -0.58dBi Exposure category : General population/uncontrolled environment EUT Type : Production Unit Device Type : Portable Device Page 2 of 4 FCC ID:2A75Q-TA3000 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity 2. Evaluation method and Limit According to KDB447498 D01 General RF Exposure Guidance v06 Section 4.3.1 Standalone SAR test exclusion considerations: “Unless specifically required by the published RF exposure KDB procedures, standalone 1-g head or body and 10-g extremity SAR evaluation for general population exposure conditions, by measurement or numerical simulation, is not required when the corresponding SAR Test Exclusion Threshold condition, listed below, is satisfied. These test exclusion conditions are based on source-based time-averaged maximum conducted output power of the RF channel requiring evaluation, adjusted for tune-up tolerance, and the minimum test separation distance required for the exposure conditions.22 The minimum test separation distance is determined by the smallest distance from the antenna and radiating structures or outer surface of the device, according to the host form factor, exposure conditions and platform requirements, to any part of the body or extremity of a user or bystander (see 5) of section 4.1). To qualify for SAR test exclusion, the test separation distances applied must be fully explained and justified by the operating configurations and exposure conditions of the transmitter and applicable host platform requirements, typically in the SAR measurement or SAR analysis report, according to the required published RF exposure KDB procedures. When no other RF exposure testing or reporting is required, a statement of justification and compliance must be included in the equipment approval, in lieu of the SAR report, to qualify for the SAR test exclusion. When required, the device specific conditions described in the other published RF exposure KDB procedures must be satisfied before applying these SAR test exclusion provisions; for example, handheld PTT two-way radios, handsets, laptops & tablets etc.“ [(max. power of channel, including tune-up tolerance, mW)/ (min. test separation distance, mm)] · [√f (GHz)] ≤ 3.0 for 1-g SAR and ≤ 7.5 for 10-g extremity SAR, where: • f (GHz) is the RF channel transmit frequency in GHz • Power and distance are rounded to the nearest mW and mm before calculation • The result is rounded to one decimal place for comparison • 3.0 and 7.5 are referred to as the numeric thresholds in the step 2 below The test exclusions are applicable only when the minimum test separation distance is ≤ 50 mm and for transmission frequencies between 100 MHz and 6 GHz. When the minimum test separation distance is < 5 mm, a distance of 5 mm according to f) in section 4.1 is applied to determine SAR test exclusion. When one of the following test exclusion conditions is satisfied for all combinations of simultaneous transmission configurations, further equipment approval is not required to incorporate transmitter modules in host devices that operate in the mixed mobile and portable host platform exposure conditions. The grantee is responsible for documenting this according to Class I permissive change requirements. Antennas that qualify for standalone SAR test exclusion must apply the estimated standalone SAR to determine simultaneous transmission test exclusion. a) The [∑ of (the highest measured or estimated SAR for each standalone antenna configuration, adjusted for maximum tune-up tolerance) / 1.6 W/kg] + [∑ of MPE ratios] is ≤ 1.0. b)The SAR to peak location separation ratios of all simultaneously transmitting antenna pairs operating in portable device exposure conditions are all ≤ 0.04, and the [∑ of MPE ratios] is ≤ 1.0. 3. Refer Evaluation Method ANSI C95.1–1999: IEEE Standard for Safety Levels with Respect to Human Exposure to Radio Frequency Electromagnetic Fields, 3 kHz to 300 GHz. FCC KDB publication 447498 D01 General RF Exposure Guidance v06: Mobile and Portable Devices RF Exposure Procedures and Equipment Authorization Policies. FCC CFR 47 part1 1.1310: Radiofrequency radiation exposure limits. FCC CFR 47 part2 2.1093: Radiofrequency radiation exposure evaluation: portable devices Page 3 of 4 FCC ID:2A75Q-TA3000 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity 4. Conducted Power Results <BT> Mode Channel Frequency (MHz) Peak Conducted Output Power (dBm) GFSK 0 2402 0.07 39 2441 0.21 78 2480 0.22 π/4-DQPSK 0 2402 -0.28 39 2441 -0.14 78 2480 -0.10 8-DPSK 0 2402 -0.18 39 2441 -0.04 78 2480 0.35 <BT LE> Mode Channel Frequen…

Text truncated - open the document above for the full version.

Test Report

Inverted F Antenna Specification Summary ITEM ANT SPEC Model Name 2.4G ANT Horizontal Vertical 2400MHz 2400MHz2500MHz2400MHz2400MHz 2500MHz Center Frequency -1.26 -0.76 -0.58 -5.25 -2.46 -1.86 MAX. Gain -0.58dB Polarization Horizontal and Vertical Azimuth Beam Pattern Omni-directional Impedance 50 Ohm Antenna Length 38.20mm Manufacture ZHUHAI JIELI TECHNOLOGY CO.,LTD Antenna Photo & Length (mm) Horizontal: 2400 MHz 2450 MHz 2500 MHz Power (dBm) Max: 0 Min: -40 Scale: 5/div Gain(dB) Frequency (MHz) Max Min Avg 2400 -1.26174 -30.0801 -7.18716 2450 -0.765802 -36.5604 -7.48023 2500 -0.585582 -22.0315 -6.59127 Vertical: 2400 MHz 2450 MHz 2500 MHz Power (dBm) Max: 0 Min: -30 Scale: 5/div Gain(dB) Frequency (MHz) Max Min Avg 2400 -5.2537 -22.1424 -12.4294 2450 -2.4652 -24.5837 -10.4702 2500 -1.86120 -29.5214 -9.20432 ANT Test Labs:Attestation of Global Compliance Co., Ltd.

Test Report

Page 1 of 54 FCC ID:2A75Q-TA3000 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Appendix A RF Test Data for BT (Conducted Measurement) Product Name: TA3000 WirelessGaming headset Test Model: TA3000 Environmental Conditions Temperature: 23.8  C Relative Humidity: 52.1% ATM Pressure: 100.0 kPa Test Engineer: Joker Hu Supervised by: Ling Zhu Page 2 of 54 FCC ID:2A75Q-TA3000 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity A.1 -20dB Bandwidth Condition Mode Frequency (MHz) Antenna -20 dB Bandwidth (MHz) Limit -20 dB Bandwidth (MHz) Verdict NVNT 1-DH5 2402 Ant 0.959 N/A Pass NVNT 1-DH5 2441 Ant 1.017 N/A Pass NVNT 1-DH5 2480 Ant 1.013 N/A Pass NVNT 2-DH5 2402 Ant 1.29 N/A Pass NVNT 2-DH5 2441 Ant 1.285 N/A Pass NVNT 2-DH5 2480 Ant 1.315 N/A Pass NVNT 3-DH5 2402 Ant 1.295 N/A Pass NVNT 3-DH5 2441 Ant 1.296 N/A Pass NVNT 3-DH5 2480 Ant 1.273 N/A Pass Page 3 of 54 FCC ID:2A75Q-TA3000 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Test Graphs -20dB Bandwidth NVNT 1-DH5 2402MHz Ant -20dB Bandwidth NVNT 1-DH5 2441MHz Ant Page 4 of 54 FCC ID:2A75Q-TA3000 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity -20dB Bandwidth NVNT 1-DH5 2480MHz Ant -20dB Bandwidth NVNT 2-DH5 2402MHz Ant Page 5 of 54 FCC ID:2A75Q-TA3000 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity -20dB Bandwidth NVNT 2-DH5 2441MHz Ant -20dB Bandwidth NVNT 2-DH5 2480MHz Ant Page 6 of 54 FCC ID:2A75Q-TA3000 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity -20dB Bandwidth NVNT 3-DH5 2402MHz Ant -20dB Bandwidth NVNT 3-DH5 2441MHz Ant Page 7 of 54 FCC ID:2A75Q-TA3000 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity -20dB Bandwidth NVNT 3-DH5 2480MHz Ant Page 8 of 54 FCC ID:2A75Q-TA3000 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity A.2 Maximum Conducted Output Power Condition Mode Frequency (MHz) Antenna Total Power (dBm) Limit (dBm) Verdict NVNT 1-DH5 2402 Ant 0.07 21 Pass NVNT 1-DH5 2441 Ant 0.21 21 Pass NVNT 1-DH5 2480 Ant 0.22 21 Pass NVNT 2-DH5 2402 Ant -0.28 21 Pass NVNT 2-DH5 2441 Ant -0.14 21 Pass NVNT 2-DH5 2480 Ant -0.10 21 Pass NVNT 3-DH5 2402 Ant -0.18 21 Pass NVNT 3-DH5 2441 Ant -0.04 21 Pass NVNT 3-DH5 2480 Ant 0.35 21 Pass Page 9 of 54 FCC ID:2A75Q-TA3000 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Test Graphs Power NVNT 1-DH5 2402MHz Ant Power NVNT 1-DH5 2441MHz Ant Page 10 of 54 FCC ID:2A75Q-TA3000 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Power NVNT 1-DH5 2480MHz Ant Power NVNT 2-DH5 2402MHz Ant Page 11 of 54 FCC ID:2A75Q-TA3000 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Power NVNT 2-DH5 2441MHz Ant Power NVNT 2-DH5 2480MHz Ant Page 12 of 54 FCC ID:2A75Q-TA3000 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Power NVNT 3-DH5 2402MHz Ant Power NVNT 3-DH5 2441MHz Ant Page 13 of 54 FCC ID:2A75Q-TA3000 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Power NVNT 3-DH5 2480MHz Ant Page 14 of 54 FCC ID:2A75Q-TA3000 Shenzhen LCS Compl…

Text truncated - open the document above for the full version.

Test Report

Page 1 of 36 FCC ID:2A75Q-TA3000 Report No.: LCSA062123086EA Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity FCC TEST REPORT FOR Guangzhou Weijunda Network Technology Co., Ltd. TA3000 WirelessGaming headset Test Model: TA3000 Prepared for : Guangzhou Weijunda Network Technology Co., Ltd. Address : No. 35, Lixiang Road,Licheng street, Zengcheng District, Guangzhou, China Prepared by : Shenzhen LCS Compliance Testing Laboratory Ltd. Address : 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel : (+86)755-82591330 Fax : (+86)755-82591332 Web : www.LCS-cert.com Mail : [email protected] Date of receipt of test sample : June 29, 2023 Number of tested samples : 2 Sample No. : A062123086-1, A062123086-2 Serial number : Prototype Date of Test : June 29, 2023 ~ July 12, 2023 Date of Report : July 13, 2023 Page 2 of 36 FCC ID:2A75Q-TA3000 Report No.: LCSA062123086EA Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity FCC TEST REPORT FCC CFR 47 PART 15 C (15.247) Report Reference No. ................. : LCSA062123086EA Date of Issue ................................... : July 13, 2023 Testing Laboratory Name ............ : Shenzhen LCS Compliance Testing Laboratory Ltd. Address ........................................... : 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Testing Location/ Procedure ........... : Full application of Harmonised standards ■ Partial application of Harmonised standards □ Other standard testing method □ Applicant’s Name .......................... : Guangzhou Weijunda Network Technology Co., Ltd. Address ........................................... : No. 35, Lixiang Road,Licheng street, Zengcheng District, Guangzhou, China Test Specification Standard.......................................... : FCC CFR 47 PART 15 C (15.247) Test Report Form No. ..................... : LCSEMC-1.0 TRF Originator ................................ : Shenzhen LCS Compliance Testing Laboratory Ltd. Master TRF ..................................... : Dated 2011-03 Shenzhen LCS Compliance Testing Laboratory Ltd. All rights reserved. This publication may be reproduced in whole or in part for non-commercial purposes as long as the Shenzhen…

Text truncated - open the document above for the full version.

Contact Information

Applicant

Qi Zhou Zi
[email protected]13538218145Fax: 13266861229

Test Firm

Shenzhen LCS Compliance Testing Laboratory Ltd.Gavin Liang
[email protected]0755-82591330Fax: 0755-82591132

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.40 GHz - 2.48 GHz1.10 mW
Confidentiality
Long Term
Grant Notes
Output power listed is peak conducted output power.

Other Applications from Guangzhou Weijunda Network Technology Co., Ltd.

TA2000 WirelessGaming headset - FCC ID 2A75Q-TA2000 - Guangzhou Weijunda Network Technology Co., Ltd.
2A75Q-TA2000

TA2000 WirelessGaming headset

Jul 16, 2023

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter
2A75Q-TA83 - FCC ID 2A75Q-TA83 - Guangzhou Weijunda Network Technology Co., Ltd.
2A75Q-TA83

2A75Q-TA83

Jul 16, 2023

Equipment Class

DTS - Digital Transmission System
G926 headset - FCC ID 2A75QG926 - Guangzhou Weijunda Network Technology Co., Ltd.
2A75QG926

G926 headset

Aug 03, 2022

Equipment Class

DTS - Digital Transmission System