111.5~205KHz RF Exposure: A distance of 20 cm shall be maintained between the antenna and users, and the transmitter may not be co-located with any other transmitter or antenna.
Co m Ad d Ave Pr o Mo d Pr o We act We an d issu our Sig Na m Title Com mpany: She dress: 8th F nue, Gushu, oduct Name del Numbe oduct Desc authorize M on our beha declare tha d certificatio ues concern behalf shal nature: me: e: mpany: Sh enzhen Aok Floor, Buildin Xixiang, Ba e: Multi-funct er(s): T40 ription: Mu MiCOM Lab alf on all ma at MiCOM L n of equipm ning the app ll have the s Corinna W Manager Shenzhen henzhen Ao Agen ke Power T ng B2, Huafe oan District, tional Wirele lti-functional bs Inc., 575 atters conce Labs Inc. is ment to the r proval applic same effect Wu n Aoke Pow oke Power nt Auth echnology C ng Century S Shenzhen, C ess Charging Wireless C h Boulder Co erning the c allowed to f regulatory a cation. Any t as acts of er Technolo Technolog horizat Co., Ltd. Science and China ala rm clock harging alarm ourt, Pleasa certification forward all i agencies as and all acts our own. ogy Co., Ltd gy Co., Ltd. tion Technology m clock anton, Califo of above na information s required a s carried ou Date: d. Park, Hangc ornia 94566 amed equip related to t nd to discu ut by MiCOM Jun. 20, 20 cheng 6, USA, to pment. the approva ss any M Labs on 22 al
Office o Federa 7435 O Columb USA Subjec t FCC ID To Wh o Pursua are req u docume These d propriet might b It is ou r corresp docume authoriz Sincer e Signat u Name: Title: M of Engineeri l Communic Oakland Mills bia, MD 210 t; Request f D: 2A7CP-T om It May C nt to the pro uesting the ents from pu documents tary informa be harmful to Schema Block D Parts Lis Operatio r understand pondence du ents and thi zation is iss ely, ure: Corinna W u anager Shen ing Techno cations Com s Road 046 for Confiden T40 Concern, ovisions of t Commissio ublic disclos contain det ation in ope o our comp atic Diagram iagram st onal Descri ding that all uring the ce s informatio sued. u nzhen Aoke logy mmission ntiality the Commis on to withho sure indefin tailed syste ration of th e any and wo m ption l measurem ertification re on will be av e Power Te ssion’s rule old the follow nitely. m and equi e equipmen ould give co ment test rep eview proce vailable for echnology s Title 47 S wing attach pment desc nt. The publ ompetitors a ports, FCC ess cannot public revi e Co., Ltd. Sections §0. hment(s) as criptions an ic disclosu r an unfair ad ID label for be granted ew once the Date: Jun. 457 and §0 confidentia d are consi re of these d vantage in mat and as confide n e grant of eq 20, 2022 0.459, we al dered as documents the market . ntial quipment .
Annex A External Photos Report No.: HK2206092486-1E/2E Page 1 of 4 Report No.: HK2206092486-1E/2E Page 2 of 4 Report No.: HK2206092486-1E/2E Page 3 of 4 Report No.: HK2206092486-1E/2E Page 3 of 4
FCC ID LABEL: Ca. 8mm x 10mm Label Location FCC ID: 2A7CP-T40
Annex B Internal Photo Report No.: HK2206092486-1E/2E Page 1 of 3 Antenna 1 Antenna 2 Report No.: HK2206092486-1E/2E Page 2 of 3 Report No.: HK2206092486-1E/2E Page 3 of 3
Page 1 of 10 Report No.: HK2206092486-2E FCC TEST REPORT Test report On Behalf of Shenzhen Aoke Power Technology Co., Ltd. For Multi-functional Wireless Charging alarm clock Model No.: T40 FCC ID: 2A7CP-T40 Prepared For : Shenzhen Aoke Power Technology Co., Ltd. 8th Floor, Building B2, Huafeng Century Science and Technology Park, Hangcheng Avenue, Gushu, Xixiang, Baoan District, Shenzhen, China Prepared By : Shenzhen HUAK Testing Technology Co., Ltd. 1-2/F., Building B2, Junfeng Zhongcheng Zhizao Innovation Park, Heping, Fuhai Street, Bao’an District, Shenzhen, Guangdong, China Date of Test: Jun. 09, 2022 ~ Jun. 16, 2022 Date of Report: Jun. 16, 2022 Report Number: HK2206092486-2E Page 2 of 10 Report No.: HK2206092486-2E Note: 1. For a more detailed features description, please refer to the manufacturer’s specifications or the User's Manual. 2. Channel List Channel Frequency (KHz) Channel Frequency (MHz) Channel Frequency (MHz) Channel Frequency (MHz) 01 124 The EUT antenna is Coil Antenna. No antenna other than that furnished by the responsible party shall be used with the device. 2. SUMMARY OF TEST RESULTS 2.1. Test procedures according to the technical standards: FCC KDB680106 D01 RF Exposure Wireless Charging Apps v03r01 FCC CFR 47 Standard Section Test Item Judgment Remark FCC CFR 47 part1, 1.1310 KDB680106 D01v03r01 (3)(3) Electric Field Strength (E) (V/m) PASS Magnetic Field Strength (H) (A/m) PASS 2.2. Measurement Uncertainty The reported uncertainty of measurement y ±U, where expended uncertainty U is based on a standard uncertainty multiplied by a coverage factor of k=2, providing a level of confidence of approximately 95 %. No. Item Uncertainty 1 All emissions, radiated(<30M)(9KHz-30MHz) ±3.90dB 2 Temperature ±0.5°C 3 Humidity ±2% Page 3 of 10 Report No.: HK2206092486-2E 2.3. Test Mode EUT Mode Description Charging ANT 1 Cell load setting 10W Cell load setting 7.5W Cell load setting 5W ANT 2 Cell Headset setting 1.0W ANT 1+ANT 2 Cell load setting 10W+ Cell Headset setting 1.0W 2.4. Test Instruments Description Brand Model No. Frequency Range Calibrated Date Calibrated Until Exposure Level Te s t e r narda ELT-400 N-0231 Feb. 18, 2022 Feb. 17, 2023 Magnetic field probe 100cm 2 narda ELT probe 100cm2 M0675 Feb. 18, 2022 Feb. 17, 2023 NOTE: 1. The calibration interval of the above test instruments is 12 months. Page 4 of 10 Report No.: HK2206092486-2E 3. MAXIMUM PERMISSIBLE EXPOSURE Limit of Maximum Permissible Exposure Limits for Occupational / Controlled Exposure Frequency Range (MHz) Electric Field Strength (E) (V/m) Magnetic Field Strength (H) (A/m) Power Density (S) (mW/ cm²) Averaging Time |E|²,|H|² or S (minutes) 0.3-3.0 614 1.63 (100)* 6 3.0-30 1842 / f 4.89 / f (900 / f)* 6 30-300 61.4 0.163 1.0 6 300-1500 F/300 6 1500-100,000 5 6 Limits for General Population / Uncontrolled Exposure Frequency Range (MHz) Electric Field Strength (E) (V/m) Magnetic Field Strength (H) (A/m) Power Density (S) (mW/ cm²) Averaging Time |E|²,|H|² or S (minutes) 0.3-1.34 614 1.63 (100)* 30 1.34-30 824/f 2.19/f (180 / f)* 30 30-300 27.5 0.073 0.2 30 300-1500 F/1500 30 1500-100,000 1 30 Note 1: f = frequency in MHz ; *Plane-wave equivalent power density. Note 2: For the applicable limit, see FCC 1.1310, 680106 D01 RF Exposure Wireless Charging Apps v03. Note 3: Emissions between 100 kHz to 300 kHz should be assessed versus the limits at 300 kHz in Table 1 of Section 1.1310: 614 V/m and 1.63A/m. A KDB inquiry is required to determine the applicable exposure limits below 100 kHz. Page 5 of 10 Report No.: HK2206092486-2E 4. TEST PROCEDURE a. For devices designed for typical desktop applications, such a wireless charging pads, RF exposure evaluation should be conducted assuming a user separation distance of (H-field & E- field strengths for all sides is 15cm, H-field strengths of top side is 20cm). E and H field strength measurements or numerical modeling may be used to demonstrate compliance. Measurements should be made from all sides and the top of the primary/client pair, with the 15 cm measured from the center of the probe(s) to the edge of the device. 4.1 Test Setup 4.2 Result Of Maximum Permissible Exposure Page 6 of 10 Report No.: HK2206092486-2E All test modes are tested, and the report shows only the worst mode: ANT1+ANT2 H-Field Strength at 15 cm (E top side: 20cm) from the edges surrounding the EUT (A/m) Field strength Test Position A Test Position B Test Position C Test Position D Test Position E Limits (A/m) uT 0.088 0.127 0.268 0.332 0.574 / A/m 0.070 0.102 0.214 0.266 0.459 1.63 Note. Calculation: A/m=uT/1.25 For Half Load mode: H-Field Strength at 15 cm (E top side: 20cm) from the edges surrounding the EUT (A/m) Field strength Test Position A Test Position B Test Position C Test Position D Test Position E Limits (A/m) uT 0.125 0.147 0.225 0.288 0.366 / A/m 0.100 0.118 0.180 0.230 0.293 1.63 Note. Calculation: A/m=uT/1.25 For No load mode: H-Field Strength at 15 cm (E top side: 20cm) from the edges surrounding the EUT (A/m) Field strength Test Position A Test Position B Test Position C Test Position D Test Position E Limits (A/m) uT 0.321 0.302 0.217 0.368 0.510 / A/m 0.257 0.242 0.174 0.294 0.408 1.63 Note. Calculation: A/m=uT/1.25 Page 7 of 10 Report No.: HK2206092486-2E Remark: According KDB 680106 D01 RF Exposure Wireless Charging App v03r01, section 5, b). The aggregate H-field strengths at 15 cm surrounding the device and 20 cm above the top surface from all simultaneous transmitting coils are demonstrated to be less than 50% of the MPE limit. The E- field evaluation conducted assuming a user separation distance of 15 cm according to the KDB 680106 D01 RF Exposure Wireless Charging App v03 section 3, c). Result: The device comply with the RF exposure requirement according to 680106 D01 v03r01, section 5, b): (1) The operating frequency is 111.5KHz~205KHz, is less than 1MHz. (2) The max Output power for each primary coil is 10W, ≤ 10W. (3) The system may consist of more than one s…
Text truncated - open the document above for the full version.
Page 1 of 21 Report No.: HK2206092486-1E FCC TEST REPORT Test report On Behalf of Shenzhen Aoke Power Technology Co., Ltd. For Multi-functional Wireless Charging alarm clock Model No.: T40 FCC ID: 2A7CP-T40 Prepared For : Shenzhen Aoke Power Technology Co., Ltd. 8th Floor, Building B2, Huafeng Century Science and Technology Park, Hangcheng Avenue, Gushu, Xixiang, Baoan District, Shenzhen, China Prepared By : Shenzhen HUAK Testing Technology Co., Ltd. 1-2/F., Building B2, Junfeng Zhongcheng Zhizao Innovation Park, Heping, Fuhai Street, Bao’an District, Shenzhen, Guangdong, China Date of Test: Jun. 09, 2022 ~ Jun. 16, 2022 Date of Report: Jun. 16, 2022 Report Number: HK2206092486-1E Page 2 of 21 Report No.: HK2206092486-1E TEST RESULT CERTIFICATION Applicant’s name ................. : Shenzhen Aoke Power Technology Co., Ltd. Address.................................. : 8th Floor, Building B2, Huafeng Century Science and Technology Park, Hangcheng Avenue, Gushu, Xixiang, Baoan District, Shenzhen, China Manufacture's Name ............ : Shenzhen Aoke Power Technology Co., Ltd. Address.................................. : 8th Floor, Building B2, Huafeng Century Science and Technology Park, Hangcheng Avenue, Gushu, Xixiang, Baoan District, Shenzhen, China Product description Trade Mark: N/A Product name ............................ : Multi-functional Wireless Charging alarm clock Model and/or type reference : T40 Standards ............................. : FCC CFR 47 PART 18 This publication may be reproduced in whole or in part for non-commercial purposes as long as the Shenzhen HUAK Testing Technology Co., Ltd. is acknowledged as copyright owner and source of the material. Shenzhen HUAK Testing Technology Co., Ltd. takes no responsibility for and will not assume liability for damages resulting from the reader's interpretation of the reproduced material due to its placement and context. Date of Test ............................................ : Date (s) of performance of tests ............. : Jun. 09, 2022 ~ Jun. 16, 2022 Date of Issue ........................................... : Jun. 16, 2022 Test Result ............................................... : Pass Testing Engineer : (Gary Qian) Technical Manager : (Eden Hu) Authorized Signatory : (Jason Zhou) Page 3 of 21 Report No.: HK2206092486-1E Table of Contents Page 1 . TEST SUMMARY 5 1.1 . Test Procedures And Results 5 1.2 . Information of the Test Laboratory 5 1.3 . Measurement Uncertainty 5 2. GENERAL INFORMATION 6 2.1. General Description of EUT 6 2.2. Carrier Frequency of Channels 7 2.3. Operation of EUT during testing 7 2.4. Test Mode 7 2.5. Description of Test Setup 8 2.6. Measurement Instruments List 9 3. CONDUCTED EMISSION TEST 10 3.1. Block Diagram of Test Setup 10 3.2. Conducted Power Line Emission Limit 10 3.3. Test Procedure 10 4. RADIATED EMISSIONS 13 4.1. Block Diagram of Test Setup 13 4.2. Rules and specifications 13 4.3. Test Procedure 14 4.4. Test Result 14 5. ANTENNA REQUIREMENT 18 6. PHOTOGRAPH OF TEST 19 7. PHOTOS OF THE EUT 21 Page 4 of 21 Report No.: HK2206092486-1E ** Modified History ** Revision Description Issued Data Remark Revision 1.0 Initial Test Report Release Jun. 16, 2022 Jason Zhou Page 5 of 21 Report No.: HK2206092486-1E 1. TEST SUMMARY 1.1. Test Procedures And Results DESCRIPTION OF TEST SECTION NUMBERRESULT CONDUCTED EMISSIONS TEST 18.307 COMPLIANT RADIATED EMISSION TEST 18.305 COMPLIANT Note: 1. PASS: Test item meets the requirement. 2. Fail: Test item does not meet the requirement. 3. N/A: Test case does not apply to the test object. 4. The test result judgment is decided by the limit of test standard. 1.2. Information of the Test Laboratory Shenzhen HUAK Testing Technology Co., Ltd. Add.: 1-2/F., Building B2, Junfeng Zhongcheng Zhizao Innovation Park, Heping, Fuhai Street, Bao’an District, Shenzhen, Guangdong, China Testing Laboratory Authorization: A2LA Accreditation Code is 4781.01. FCC Designation Number is CN1229. Canada IC CAB identifier is CN0045. CNAS Registration Number is L9589. 1.3. Measurement Uncertainty Measurement Uncertainty Conducted Emission Expanded Uncertainty =2.71dB, k=2 Radiated emission expanded uncertainty(9kHz-30MHz) = 3.90dB, k=2 Radiated emission expanded uncertainty(30MHz-1000MHz)= 3.90dB, k=2 Radiated emission expanded uncertainty(Above 1GHz) = 4.28dB, k=2 Page 6 of 21 Report No.: HK2206092486-1E 2. GENERAL INFORMATION 2.1. General Description of EUT Equipment: Multi-functional Wireless Charging alarm clock Model Name: T40 Series Models: N/A Model Difference: N/A Trade Mark: N/A FCC ID: 2A7CP-T40 Antenna Type: Coil Antenna Antenna Gain: 0dBi Operation frequency: 111.5KHz~205KHz Test frequency: 124KHz Number of Channels: 1 Modulation Type: ASK Power Source: Charger Input: DC 5V/2A or 9V/1.67A Charger Output: 5W/7.5W/10W Output(Headset): 5V 200MA Output(USB): 5V 200MA Power Rating: Charger Input: DC 5V/2A or 9V/1.67A Charger Output: 5W/7.5W/10W Output(Headset): 5V 200MA Output(USB): 5V 200MA Page 7 of 21 Report No.: HK2206092486-1E 2.2. Carrier Frequency of Channels Operation Frequency each of channel Channel Frequency 1 124KHz 2.3. Operation of EUT during testing Operating Mode The mode is used: Transmitting mode 2.4. Test Mode EUT Mode Description Charging ANT 1 Cell load setting 10W Cell load setting 7.5W Cell load setting 5W ANT 2 Cell Headset setting 1.0W ANT 1+ANT 2 Cell load setting 10W+ Cell Headset setting 1.0W Page 8 of 21 Report No.: HK2206092486-1E 2.5. Description of Test Setup Operation of EUT during testing: AC Plug Earphone information Model: Airpods Input: DC 5V Adapter information Model: HW-059200CHQ Input: 100-240V, 50/60Hz, 0.5A Output: 5VDC, 2A The sample was placed (0.8m (30MHz~1GHz), 0.8m (9KHz~30MHz) above the ground plane of 3m chamber. Measurements in both horizontal and vertical polarities were performed. During the test, each emission was maximized by: having the EUT continuously working, investigated all operating modes, rotated about all 3 axis (X,…
Text truncated - open the document above for the full version.
Radiated Emissions Conducted Emission
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 18 | 0.1115 MHz - 0.205 MHz | - |