FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. FLASHNET SA/
  3. 2A7FA-NEMATWNB1M1G

2A7FA-NEMATWNB1M1Gintelligent street light management and control device

FLASHNET SA

Application Details

Equipment Class
JAB - Part 15 Class B Digital Device
Date of Grant
Dec 02, 2025
Application Purpose
Original Equipment
Equipment Note
intelligent street light management and control device
Company
FLASHNET SA
Country
Romania

Documents & Files

Select a file to view

Attestation Statements

↗
↗

Cover Letter(s)

↗

ID Label/Location Info

↗

RF Exposure Info

↗

Test Report

↗
↗
↗
↗
↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Attestation Statements

Covered list attestation FCC application letter Kiwa Page 1 of 2 RF_755_03 06-06-2024 FLASHNET SA, part of Lucy Group 4A Fundatura Harmanului St 500240 - Brasov, ROMANIA Phone: +40 268 333 766 Fax: +40 268 334 331 Email: [email protected] www.FLASHNET.ro Certification Application Attestation Statements <Company name> FLASHNET SA <FRN:> 0032543126 <adress> Fundatura Harmanului 4A <ZIP / Postcode>500240 <city> <country> Brasov / Romania Subject: FCC ID: 2A7FA-NEMATWNB1M1G To Whom It May Concern: Statement for 47 CFR section 2.911(d)(5)(i) FLASHNET SA certifies that as of the date of the application the equipment for which authorization is sought is not “covered” equipment 1 prohibited from receiving an equipment authorization pursuant to section 2.903 of the FCC rules. If the equipment for which the applicant seeks authorization is produced by any of the entities identified on the current Covered List, including affiliates or subsidiaries of the named companies, the applicant must include an explanation on why the equipment is not “covered” equipment. Additional Explanation: <N/A> Statement for 47 CFR section 2.911(d)(5)(ii) FLASHNET SA (“the applicant”) certifies that, as of the date of the filing of this application, the applicant - is / - is not (3) identified on the Covered List as an entity producing “covered” equipment. Date: 06.10.2025 City: Brasov Name (2) : Lorand MOZES Function: CEO Telephone number: +40 732 660 061 Email address: [email protected] 1 - The Commission’s Covered List is published by the Public Safety and Homeland Security Bureau and posted on the Commission’s website. This Covered List, which is periodically updated, identifies particular equipment, produced by particular entities, that constitutes “covered” equipment. https://www.fcc.gov/supplychain/coveredlist . (2): For FCC it must be the Grantee Code “owner” or the authorized agent. (3): double click on the appropriate box and select ‘’checked” then “OK” Covered list attestation FCC application letter Kiwa Page 2 of 2 RF_755_03 06-06-2024 FLASHNET SA, part of Lucy Group 4A Fundatura Harmanului St 500240 - Brasov, ROMANIA Phone: +40 268 333 766 Fax: +40 268 334 331 Email: [email protected] www.FLASHNET.ro Signature: Revision Record Sheet: Revision Section number Page number Date Remark(s) issued by 01 07-02-2023 1 st version RvM 02 1 15-02-2023 Changed Applicant to Company and added “Subject: FCC ID: “ RvdM 03 1 06-06-2024 FRN added at certification application and included [Insert Company Name Here] for the statements RvdM Issued/modified by : Richard van de Meer Function : Certification assessor Revision : 03 Date : 06-06-2024 Verified by : Willem Jan Jong Function : Team Lead Date : 06-06-2024 Released by : Axel Gase Function : Manager Quality Assurance Date of release: : 06-06-2024

Cover Letter(s)

FCC, Request for non-disclosure Date: 18-08-2025 RF_501, Issue 12 Page 1 of 2 Company Name: FLASHNET SA Address: Fundatura Harmanului 4A, 500240 City: Brasov Country: Romania To: Kiwa Nederland B.V., Dept. FCC TCB Wilmersdorf 50 7327 AC Apeldoorn The Netherlands Subject: Request for confidentiality FCC ID: 2A7FA-NEMATWNB1M1G Reference number: P000545607 Dear FCC TCB, 1. Long-Term Confidentiality Pursuant to 47 CFR Section 0.459(a) & (b), we hereby requests non-disclosure and confidential treatment of the following materials submitted in support of FCC certification application: Bill(s) of Material Block Diagrams Operational Description Schematic Diagrams Tune-up Procedure Above materials contain secrets, proprietary and technical information, which would customarily be guarded from competitors under 47 CFR, section 0.457(d)(2). Disclosure or publication or any portion of this company confidential material to other parties could cause substantial competitive harm and provide unjustified benefits for competitors. 2. Short-Term Confidentiality (STC) Pursuant to Public Notice DA 04-1705 of the Commission’s policy, in order to comply with the marketing regulations in 47 CFR §2.803 and the importation rules in 47 CFR §2.1204, applicant hereby requests Short-Term Confidential treatment of the following materials (See notes below): Internal Photos User’s Manual Test Set-up Photos External Photos Justification: All the above-mentioned documents contain technical information about the product, which if were to be disclosed would enable a third party to perform reverse engineering to a certain degree Date: 06.10.2025 Name and signature of applicant: Lorand MOZES Notes: 1) A document or type of document can only have ONE type of confidentiality! 2) Short-Term confidentiality is in principle for 45 days from date of grant; it can be extended max 3 times (total time 180 days max.)! The planned date should state in the RF731 application form. 3) FCC must be informed when marketing begins earlier. 4) Release takes place automatically thus extension must be requested in time. Telefication does not remind you of this! 5) Request for extension or for release must be received by Kiwa NL B.V. at least 7 days before date of actual marketing or before expiration of the STC period FCC, Request for non-disclosure Date: 18-08-2025 RF_501, Issue 12 Page 2 of 2 Revision Record Sheet: Revision Section number Page number Date Remark(s) issued by 10 1 02-01-2023 History sheet added AG 11 1 & 2 23-06-2023 Corrected date and page# WJJ 12 all 18-08-2025 Kiwa logo change AG Issued/modified by : Axel Gase Function : Manager Quality Assurance Revision : 12 Date : 18-08-2025 Verified by : Willem Jan Jong Function : Team Lead Date : 18-08-2025 Released by : Axel Gase Function : Manager Quality Assurance Date of release: : 18-08-2025

ID Label/Location Info

FLASHNET SA, part of Lucy Group 4A Fundatura Harmanului St 500240 - Brasov, ROMANIA Phone: +40 268 333 766 Fax: +40 268 334 331 Email: [email protected] www.FLASHNET.ro CUI: 18014742 EU VAT NO: RO 18014742 TRADE REGISTER NO: J2007000970087 EUID: ROONRC. J2007000970087 SUBSCRIBED & PAID-UP SHARE CAPITAL: 103.950 RON ING BANK N.V. AMSTERDAM SWIFT CODE: INGBROBU IBAN RON: RO87 INGB 0009 0081 7897 8918 IBAN EUR: RO36 INGB 0009 0081 7897 0718 IBAN USD: RO79 INGB 0009 0081 7897 4018 v1.5, June ‘25 1 / 4 Label location FRE-220-NEMA-TW-NB1-M1-G 1. Scope The purpose of this document is to present label location for the FRE-220-NEMA-TW- NB1-M1-G. 2. Introduction The product is an intelligent street light management and control device equipped with an ANSI C136.41 compliant NEMA connector, that is powered from the mains voltage via an ANSI C136.41 compliant NEMA socket located on the luminaire. It can remotely turn on/off and dim a luminaire, while measuring a wide range of electrical parameters and is capable of sending alarms in case of fault detection. It is a plug-and-play controller with full lamp management and feedback functionality. The controller has an IP66 rating and operates in the -25°C to +70°C temperature range. It has LTE Cat M1 and Cat NB2 network interfaces, having an FCC certified RF module embedded in it, namely the Telit Cinterion ME310G1-WW with FCC ID RI7ME310G1WW. FLASHNET SA, part of Lucy Group 4A Fundatura Harmanului St 500240 - Brasov, ROMANIA Phone: +40 268 333 766 Fax: +40 268 334 331 Email: [email protected] www.FLASHNET.ro CUI: 18014742 EU VAT NO: RO 18014742 TRADE REGISTER NO: J2007000970087 EUID: ROONRC. J2007000970087 SUBSCRIBED & PAID-UP SHARE CAPITAL: 103.950 RON ING BANK N.V. AMSTERDAM SWIFT CODE: INGBROBU IBAN RON: RO87 INGB 0009 0081 7897 8918 IBAN EUR: RO36 INGB 0009 0081 7897 0718 IBAN USD: RO79 INGB 0009 0081 7897 4018 v1.5, June ‘25 2 / 4 3. Label location – main label FLASHNET SA, part of Lucy Group 4A Fundatura Harmanului St 500240 - Brasov, ROMANIA Phone: +40 268 333 766 Fax: +40 268 334 331 Email: [email protected] www.FLASHNET.ro CUI: 18014742 EU VAT NO: RO 18014742 TRADE REGISTER NO: J2007000970087 EUID: ROONRC. J2007000970087 SUBSCRIBED & PAID-UP SHARE CAPITAL: 103.950 RON ING BANK N.V. AMSTERDAM SWIFT CODE: INGBROBU IBAN RON: RO87 INGB 0009 0081 7897 8918 IBAN EUR: RO36 INGB 0009 0081 7897 0718 IBAN USD: RO79 INGB 0009 0081 7897 4018 v1.5, June ‘25 3 / 4 4. Label location – statement label FLASHNET SA, part of Lucy Group 4A Fundatura Harmanului St 500240 - Brasov, ROMANIA Phone: +40 268 333 766 Fax: +40 268 334 331 Email: [email protected] www.FLASHNET.ro CUI: 18014742 EU VAT NO: RO 18014742 TRADE REGISTER NO: J2007000970087 EUID: ROONRC. J2007000970087 SUBSCRIBED & PAID-UP SHARE CAPITAL: 103.950 RON ING BANK N.V. AMSTERDAM SWIFT CODE: INGBROBU IBAN RON: RO87 INGB 0009 0081 7897 8918 IBAN EUR: RO36 INGB 0009 0081 7897 0718 IBAN USD: RO79 INGB 0009 0081 7897 4018 v1.5, June ‘25 4 / 4

RF Exposure Info

Kiwa Nederland B.V. FCC RF Exposure Report Product name : FRE-220-NEMA-TW-NB1-M1-G Applicant :Flashnet SA Test report No. : P000545607 001 v1.0 Report number: P000545607 001 v1.0 Kiwa Nederland B.V. Page 1 of 7 Laboratory information Accreditation Kiwa Nederland B.V. complies with the accreditation criteria for test laboratories as laid down in ISO/IEC 17025:2017. The accreditation covers the quality system of the laboratory as well as the specific activities as described in the authorized annex bearing the accreditation number L015 and is granted by the Dutch Council For Accreditation (RvA: Raad voor Accreditatie). Kiwa Nederland B.V. is designated by the FCC as an Accredited Test Firm for compliance testing of equipment subject to Certification under Parts 15 & 18. The Designation number is: NL0001. Kiwa Nederland B.V. is a Wireless Device Testing laboratory recognized by Innovation, Science and Economic Development Canada to test to Canadian radio equipment requirements. The Industry Canada company number for Kiwa Nederland B.V. is: 4173A. The CABID is NL0001. Kiwa Nederland B.V. is a registered Conformity Assessment body (CAB) under the Japan-EC MRA (Agreement on Mutual Recognition between Japan and the European Community). The registration number is: 201. Documentation The test report must always be reproduced in full; reproduction of an excerpt only is subject to written approval of the testing laboratory. The documentation of the testing performed on the tested devices is archived for 10 years at Kiwa Nederland B.V. Testing Location Test Site Kiwa Nederland B.V. Test Site location Wilmersdorf 50 7327 AC Apeldoorn The Netherlands Tel. +31 88998 3393 Test Site FCC NL0001 CABID NL0001 Report number: P000545607 001 v1.0 Kiwa Nederland B.V. Page 2 of 7 Revision History Version Date Remarks By v0.5 14-11-2025 First draft RvB v1.0 26-11-2025 Initial release PvW Report number: P000545607 001 v1.0 Kiwa Nederland B.V. Page 3 of 7 Table of Contents Revision History ............................................................................................................................................... 2 1 General Description ................................................................................................................................. 4 1.1 Applicant ............................................................................................................................................... 4 1.2 Manufacturer ........................................................................................................................................ 4 1.3 Tested Equipment Under Test (EUT) ..................................................................................................... 4 1.4 Applicable standards ............................................................................................................................. 4 1.5 Conclusions ........................................................................................................................................... 5 2 SAR exclusion Evaluation ......................................................................................................................... 6 2.1 Transmitter specifications ..................................................................................................................... 6 2.2 Evaluation calculations .......................................................................................................................... 7 2.3 Conclusion ............................................................................................................................................. 7 Report number: P000545607 001 v1.0 Kiwa Nederland B.V. Page 4 of 7 1 General Description 1.1 Applicant Client name: SC Flashnet SA Address: Fundatura Harmanului Street no. 4 A Zip Code: 500240 Brasov Country: Romania Telephone: +40 744 208 313 E-mail: [email protected] Contact name: Ioan CHISELITA 1.2 Manufacturer Manufacturer name: SC Flashnet SA Address: Fundatura Harmanului Street no. 4 A Zip Code: 500240 Brasov Country: Romania Telephone: +40 744 208 313 E-mail: [email protected] Contact name: Ioan CHISELITA 1.3 Tested Equipment Under Test (EUT) Product name: FRE-220-NEMA-NB1-M1-G Brand name: Flashnet Product description: smart lighting controller with NEMA socket/ The EUT is a street light management and control device that can remotely turn on/off and dim a luminaire, while measuring a wide range of electrical parameters and capable of sending alarms in case of fault detection. Variant model(s): -- Batch and/or serial No. -- Software version: App:4941, RF:4811 Hardware version: NEMA_ME310G1-WW_v4 Date of receipt 03-10-2025/ Not tested at Kiwa Apeldoorn Tests started: 08-10-2025/ Not tested at Kiwa Apeldoorn Testing ended: 10-10-2025/ Not tested at Kiwa Apeldoorn 1.4 Applicable standards 47 CFR § 1.1307 (b)(1)(i)(A) Report number: P000545607 001 v1.0 Kiwa Nederland B.V. Page 5 of 7 1.5 Conclusions The sample of the product showed NO NON-COMPLIANCES to the specifications stated in paragraph 1.4 of this report. The results of the test as stated in this report, are exclusively applicable to the product items as identified in this report. Kiwa Netherland B.V. accepts no responsibility for any properties of product items in this test report, which are not supported by the tests as specified in paragraph 1.4 “Applicable standards”. Assessment is performed by: Name : ing. R. van Barneveld Review of assessment methods and report by: Name : P. van Wanrooij, BASc The above conclusions have been verified by the following signatory: Date : 26-11-2025 Name : P. van Wanrooij Function : Test Engineer Signature : Report number: P000545607 001 v1.0 Kiwa Nederland B.V. Page 6 of 7 2 SAR exclusion Evaluation 2.1 Transmitter specifications Transmitter 1 Variable (unit) Value Symbol Conducted time-averaged output power (mW) 415.91 P Time-averaged output power ERP (mW) 415.91 P ERP…

Text truncated - open the document above for the full version.

Test Report

Page 1 of 38 File Name: Flashnet SA.15092-1 Issue 01 QMF21J - Issue 05 - KEC Issue 02; 47 CFR Part 22H 2024 Radio Test Report Flashnet SA FRE-220-NEMA-TW-NB1-M1-G 47 CFR Part 22H:2024 Effective Date 1st October 2024 PCB: PCS Licensed Transmitter Test Date: 6th October 2025 to 7th October 2025 Report Number: 10-15092-1-25 Issue 01 The testing was carried out by Kiwa Ltd trading as Kiwa Electrical Compliance, an independent test house, at their test facility located at: Kiwa Ltd, Kiwa Electrical Compliance Arnolds Court Arnolds Farm Lane Mountnessing Essex CM13 1UT U.K. www.Kiwa.com Telephone: +44 (0) 1277 352219 Email: [email protected] This laboratory is accredited in accordance with the recognised Internaonal Standard ISO/IEC 17025. This accreditaon demonstrates technical competence for a defined scope and the operaon of a laboratory quality management system (refer joint ISO-ILAC-IAF communiqué dated April 2017). This report is not to be reproduced by any means except in full and in any case not without the written approval of Kiwa Electrical Compliance. ©2025 Kiwa Ltd t/a Kiwa Electrical ComplianceREPORT NUMBER: 10-15092-1-25 Issue 01 ALL RIGHTS RESERVED Page 2 of 38 File Name: Flashnet SA.15092-1 Issue 01 QMF21J - Issue 05 - KEC Issue 02; 47 CFR Part 22H 2024 Arnolds Court, Arnolds Farm Lane, Mountnessing, Brentwood Essex, CM13 1UT Certificate of Test 15092-1 The equipment noted below has been partially tested by Kiwa Electrical Compliance and, where appropriate, conforms to the relevant subpart of 47 CFR Part 22H. This is a certificate of test only and should not be confused with an equipment authorisation. Other standards may also apply. Equipment: FRE-220-NEMA-TW-NB1-M1-G Model Number: NEMA_ME310G1-WW_v4 Unique Serial Number: 269101892 Applicant: Flashnet SA Fundatura Harmanului Street, No 4, Brasov Romania 500240 Full measurement results are detailed in Report Number: 10-15092-1-25 Issue 01 Test Standards: 47 CFR Part 22H:2024 Effective Date 1st October 2024 PCB: PCS Licensed Transmitter NOTE: With reference to the Rule part detailed, not all tests within the Rule part have been applied at the request of the applicant. The following tests have not been performed at the request of Flashnet SA:- Occupied bandwidth, Frequency stability, Band edge compliance, Modulation characteristics. Certain tests were not performed based upon applicant's declarations. Certain other requirements are subject to applicant's declaration only and have not been tested/verified. For details refer to section 3 of this report. Note: EUT contains FCC ID: RI7ME310G1WW. DEVIATIONS: Deviations have been applied, refer to section 4.2. This certificate relates only to the unit tested as identified by a unique serial number and in the condition at the time it was tested. It does not relate to any other similar equipment and performance of the product before or after the test cannot be guaranteed. Whilst every effort is made to assure quality of testing, type tests are not exhaustive and although no non-conformances may be found, this doesn't exclude the possibility of unit not meeting the intentions of the standard or the requirements of the Federal Regulations, particularly under different conditions to those during testing. Any compliance statements are made reliant on (a) the application of the product and use of the assigned band being acceptable to the FCC and (b) the modes of operation as instructed to us by the Customer based on their specific knowledge of the application and functionality of the EUT. Statements of compliance, where measurements were made, do not include the measurement uncertainty. The measurement uncertainty, where stated, is the expanded uncertainty based on a standard uncertainty multiplied by a coverage factor of k=2, providing a level of confidence of approximately 95%. Date of Test: 6th October 2025 to 7th October 2025 Test Engineer: Graham Blake Approved By: Radio Approvals Manager Customer Representative: ©2025 Kiwa Ltd t/a Kiwa Electrical ComplianceREPORT NUMBER: 10-15092-1-25 Issue 01 ALL RIGHTS RESERVED Page 3 of 38 File Name: Flashnet SA.15092-1 Issue 01 QMF21J - Issue 05 - KEC Issue 02; 47 CFR Part 22H 2024 1 Contents 1 Contents ............................................................................................................................................................. 3 2 Equipment under test (EUT) .............................................................................................................................. 4 2.1 Equipment specification ............................................................................................................................. 4 2.2 Applicant declarations for testing ............................................................................................................... 5 2.3 Functional description ................................................................................................................................ 5 2.4 Modes of operation ..................................................................................................................................... 6 2.5 Emissions configuration ............................................................................................................................. 6 3 Summary of test results ..................................................................................................................................... 8 4 Specifications ..................................................................................................................................................... 9 4.1 Relevant standards...................................................................................................................................... 9 4.2 Deviations .................................................................................................................................................... 9 4.3 Test fixtures…

Text truncated - open the document above for the full version.

Test Report

Page 1 of 40 File Name: Flashnet SA.15092-2 Issue 01 QMF21J - Issue 05 - KEC Issue 02; 47 CFR Part 24E 2024 Radio Test Report Flashnet SA FRE-220-NEMA-TW-NB1-M1-G 47 CFR Part 24E Effective Date 1st October 2024 PCB: PCS Licensed Transmitter Test Date: 7th October 2025 to 13th October 2025 Report Number: 10-15092-2-25 Issue 01 The testing was carried out by Kiwa Ltd trading as Kiwa Electrical Compliance, an independent test house, at their test facility located at: Kiwa Ltd, Kiwa Electrical Compliance Arnolds Court Arnolds Farm Lane Mountnessing Essex CM13 1UT U.K. www.Kiwa.com Telephone: +44 (0) 1277 352219 Email: [email protected] This laboratory is accredited in accordance with the recognised Internaonal Standard ISO/IEC 17025. This accreditaon demonstrates technical competence for a defined scope and the operaon of a laboratory quality management system (refer joint ISO-ILAC-IAF communiqué dated April 2017). This report is not to be reproduced by any means except in full and in any case not without the written approval of Kiwa Electrical Compliance. ©2025 Kiwa Ltd t/a Kiwa Electrical ComplianceREPORT NUMBER: 10-15092-2-25 Issue 01 ALL RIGHTS RESERVED Page 2 of 40 File Name: Flashnet SA.15092-2 Issue 01 QMF21J - Issue 05 - KEC Issue 02; 47 CFR Part 24E 2024 Arnolds Court, Arnolds Farm Lane, Mountnessing, Brentwood Essex, CM13 1UT Certificate of Test 15092-2 The equipment noted below has been partially tested by Kiwa Electrical Compliance and, where appropriate, conforms to the relevant subpart of 47 CFR Part 24E. This is a certificate of test only and should not be confused with an equipment authorisation. Other standards may also apply. Equipment: FRE-220-NEMA-TW-NB1-M1-G Model Number: NEMA_ME310G1-WW_v4 Unique Serial Number: 269101892 Applicant: Flashnet SA Fundatura Harmanului Street No 4, Brasov Romania 500240 Full measurement results are detailed in Report Number: 10-15092-2-25 Issue 01 Test Standards: 47 CFR Part 24E Effective Date 1st October 2024 PCB: PCS Licensed Transmitter NOTE: With reference to the Rule part detailed, not all tests within the Rule part have been applied at the request of the applicant. The following tests have not been performed at the request of Flashnet SA: Occupied bandwidth, Frequency stability, Modulation characteristics. Certain tests were not performed based upon applicant's declarations. Certain other requirements are subject to applicant's declaration only and have not been tested/verified. For details refer to section 3 of this report. Contains FCC ID RI7ME310G1WW. DEVIATIONS: Deviations have been applied, refer to section 4.2. This certificate relates only to the unit tested as identified by a unique serial number and in the condition at the time it was tested. It does not relate to any other similar equipment and performance of the product before or after the test cannot be guaranteed. Whilst every effort is made to assure quality of testing, type tests are not exhaustive and although no non-conformances may be found, this doesn't exclude the possibility of unit not meeting the intentions of the standard or the requirements of the Federal Regulations, particularly under different conditions to those during testing. Any compliance statements are made reliant on (a) the application of the product and use of the assigned band being acceptable to the FCC and (b) the modes of operation as instructed to us by the Customer based on their specific knowledge of the application and functionality of the EUT. Statements of compliance, where measurements were made, do not include the measurement uncertainty. The measurement uncertainty, where stated, is the expanded uncertainty based on a standard uncertainty multiplied by a coverage factor of k=2, providing a level of confidence of approximately 95%. Date of Test: 7th October 2025 to 13th October 2025 Test Engineer: Graham Blake Approved By: Radio Approvals Manager Customer Representative: ©2025 Kiwa Ltd t/a Kiwa Electrical ComplianceREPORT NUMBER: 10-15092-2-25 Issue 01 ALL RIGHTS RESERVED Page 3 of 40 File Name: Flashnet SA.15092-2 Issue 01 QMF21J - Issue 05 - KEC Issue 02; 47 CFR Part 24E 2024 1 Contents 1 Contents ............................................................................................................................................................. 3 2 Equipment under test (EUT) .............................................................................................................................. 4 2.1 Equipment specification ............................................................................................................................. 4 2.2 Applicant declarations for testing ............................................................................................................... 5 2.3 Functional description ................................................................................................................................ 5 2.4 Modes of operation ..................................................................................................................................... 5 2.5 Emissions configuration ............................................................................................................................. 6 3 Summary of test results ..................................................................................................................................... 8 4 Specifications ..................................................................................................................................................... 9 4.1 Relevant standards...................................................................................................................................... 9 4.2 Deviations .................................................................................................................................................... 9 4.3 Test fixtures ..........................................…

Text truncated - open the document above for the full version.

Test Report

Page 1 of 36 File Name: Flashnet SA.15092-3 Issue 01 QMF21J - Issue 05 - KEC Issue 02; 47 CFR Part 27 2024 Radio Test Report Flashnet SA FRE-220-NEMA-TW-NB1-M1-G 47 CFR Part 27:2024 Effective Date 1st October 2024 PCB: PCS Licensed Transmitter Test Date: 8th October 2025 to 10th October 2025 Report Number: 10-15092-3-25 Issue 01 The testing was carried out by Kiwa Ltd trading as Kiwa Electrical Compliance, an independent test house, at their test facility located at: Kiwa Ltd, Kiwa Electrical Compliance Arnolds Court Arnolds Farm Lane Mountnessing Essex CM13 1UT U.K. www.Kiwa.com Telephone: +44 (0) 1277 352219 Email: [email protected] This laboratory is accredited in accordance with the recognised Internaonal Standard ISO/IEC 17025. This accreditaon demonstrates technical competence for a defined scope and the operaon of a laboratory quality management system (refer joint ISO-ILAC-IAF communiqué dated April 2017). This report is not to be reproduced by any means except in full and in any case not without the written approval of Kiwa Electrical Compliance. ©2025 Kiwa Ltd t/a Kiwa Electrical ComplianceREPORT NUMBER: 10-15092-3-25 Issue 01 ALL RIGHTS RESERVED Page 2 of 36 File Name: Flashnet SA.15092-3 Issue 01 QMF21J - Issue 05 - KEC Issue 02; 47 CFR Part 27 2024 Arnolds Court, Arnolds Farm Lane, Mountnessing, Brentwood Essex, CM13 1UT Certificate of Test 15092-3 The equipment noted below has been partially tested by Kiwa Electrical Compliance and, where appropriate, conforms to the relevant subpart of 47 CFR Part 27. This is a certificate of test only and should not be confused with an equipment authorisation. Other standards may also apply. Equipment: FRE-220-NEMA-TW-NB1-M1-G Model Number: NEMA_ME310G1-WW_v4 Unique Serial Number: 269101892 Applicant: Flashnet SA Fundatura Harmanului Street, No 4A Brasov Romania Full measurement results are detailed in Report Number: 10-15092-3-25 Issue 01 Test Standards: 47 CFR Part 27:2024 Effective Date 1st October 2024 PCB: PCS Licensed Transmitter NOTE: With reference to the Rule part detailed, not all tests within the Rule part have been applied at the request of the applicant. The following tests have not been performed at the request of Flashnet SA:- Frequency stability, Occupied bandwidth, Band edge / spectrum mask additional emissions limitations. Certain tests were not performed based upon applicant's declarations. Certain other requirements are subject to applicant's declaration only and have not been tested/verified. For details refer to section 3 of this report. Note: EUT contains FCC ID: RI7ME310G1WW. DEVIATIONS: Deviations have been applied, refer to section 4.2. This certificate relates only to the unit tested as identified by a unique serial number and in the condition at the time it was tested. It does not relate to any other similar equipment and performance of the product before or after the test cannot be guaranteed. Whilst every effort is made to assure quality of testing, type tests are not exhaustive and although no non-conformances may be found, this doesn't exclude the possibility of unit not meeting the intentions of the standard or the requirements of the Federal Regulations, particularly under different conditions to those during testing. Any compliance statements are made reliant on (a) the application of the product and use of the assig…

Text truncated - open the document above for the full version.

Contact Information

Applicant

Lorand Mozes(CEO)
[email protected]Fax: 0040268334331

Technical Contact

FLASHNET SAAniko MIHALY
[email protected]

4A Fundatura Harmanului Brasov · Romania

Test Firm

Kiwa Assurance B.V.Dennis van der Vlugt
[email protected]

Technical Specifications

#Rule PartsFrequency RangePower Output
115B--
Confidentiality
Long Term
Grant Notes
Contains pre-certified module: FCC ID: RI7ME310G1WW. To comply with FCC radiation exposure limits for general population, the antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter.