Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
AAAAXO POWER METER CONTENT CONNECT TO CYCLING- COMPUTER AND SMART PHONE SLEEP MODE INSTALLATION CALIBRATION / ZERO RESET AXO2 or AXO2cc Power Meter×1 Stickers×1 User Guide×1 Magnetic Charging Cable×1(for AXO2) CR2032×1, Cell Cover×2(for AXO2cc) Thoroughly clean up the surface between the crank and spider till no grease or dust on it. Please install the spider to the crankarm according to the tightening torque marked on the spider. Please install the chainring to the spider according to the tightening torque printed on the chainring’s instruction book. After correctly install, use the power meter for 1 or 2 times, it would be accurate as it should. Please make sure that the crankarm is on the right side of the charging port when you install AXO2. Damage caused by incorrect installation is beyond the scope of the warranty. Rotate the crankarm backward at any time. When Power Meter is under no-load (Feet leave from pedals and pedals do not touch anything), press the cycling- computer’s ‘calibrate’ button to perform zero reset. AXO2/AXO2cc Power Meter will enter into sleep mode automatically after 5 minutes of inactivity to save power. Rotate the crankarm to activate it. AXO2/AXO2cc Power Meter is a precision mechanical measuring equipment. Please note to keep clean and accuracy during installing. AXO2/AXO2cc Power Meter can be zeroed without any manual operation. If manual zero reset is needed, there are 2 ways: Rotate the crankarm to activate AXO2 power meter. Cycling computer : Turn on the cycling-computer, search power meters and connect AXO2/AXO2cc directly, or enter it’s ANT ID to connect. Phone : When connecting to a smart phone, please turn on smart phone’s Bluetooth and choose AXO2/AXO2cc in APP directly. DO NOT pair in the Bluetooth Setting of the smart phone. · · · · · CONTENT CONNECT TO CYCLING- COMPUTER AND SMART PHONE SLEEP MODE INSTALLATION CALIBRATION / ZERO RESET AXO2 or AXO2cc Power Meter×1 Stickers×1 User Guide×1 Magnetic Charging Cable×1(for AXO2) CR2032×1, Cell Cover×2(for AXO2cc) Thoroughly clean up the surface between the crank and spider till no grease or dust on it. Please install the spider to the crankarm according to the tightening torque marked on the spider. Please install the chainring to the spider according to the tightening torque printed on the chainring’s instruction book. After correctly install, use the power meter for 1 or 2 times, it would be accurate as it should. Please make sure that the crankarm is on the right side of the charging port when you install AXO2. Damage caused by incorrect installation is beyond the scope of the warranty. Rotate the crankarm backward at any time. When Power Meter is under no-load (Feet leave from pedals and pedals do not touch anything), press the cycling- computer’s ‘calibrate’ button to perform zero reset. AXO2/AXO2cc Power Meter will enter into sleep mode automatically after 5 minutes of inactivity to save power. Rotate the crankarm to activate it. AXO2/AXO2cc Power Meter is a precision mechanical measuring equipment. Please note to keep clean and accuracy during installing. AXO2/AXO2cc Power Meter can be zeroed without any manual operation. If manual zero reset is needed, there are 2 ways: Rotate the crankarm to activate AXO2 power meter. Cycling computer : Turn on the cycling-computer, search power meters and connect AXO2/AXO2cc directly, or enter it’s ANT ID to connect. Phone : When connecting to a smart phone, please turn on smart phone’s Bluetooth and choose AXO2/AXO2cc in APP directly. DO NOT pair in the Bluetooth Setting of the smart phone. · · · · · CONTENT CONNECT TO CYCLING- COMPUTER AND SMART PHONE SLEEP MODE INSTALLATION CALIBRATION / ZERO RESET AXO2 or AXO2cc Power Meter×1 Stickers×1 User Guide×1 Magnetic Charging Cable×1(for AXO2) CR2032×1, Cell Cover×2(for AXO2cc) Thoroughly clean up the surface between the crank and spider till no grease or dust on it. Please install the spider to the crankarm according to the tightening torque marked on the spider. Please install the chainring to the spider according to the tightening torque printed on the chainring’s instruction book. After correctly install, use the power meter for 1 or 2 times, it would be accurate as it should. Please make sure that the crankarm is on the right side of the charging port when you install AXO2. Damage caused by incorrect installation is beyond the scope of the warranty. Rotate the crankarm backward at any time. When Power Meter is under no-load (Feet leave from pedals and pedals do not touch anything), press the cycling- computer’s ‘calibrate’ button to perform zero reset. AXO2/AXO2cc Power Meter will enter into sleep mode automatically after 5 minutes of inactivity to save power. Rotate the crankarm to activate it. AXO2/AXO2cc Power Meter is a precision mechanical measuring equipment. Please note to keep clean and accuracy during installing. AXO2/AXO2cc Power Meter can be zeroed without any manual operation. If manual zero reset is needed, there are 2 ways: Rotate the crankarm to activate AXO2 power meter. Cycling computer : Turn on the cycling-computer, search power meters and connect AXO2/AXO2cc directly, or enter it’s ANT ID to connect. Phone : When connecting to a smart phone, please turn on smart phone’s Bluetooth and choose AXO2/AXO2cc in APP directly. DO NOT pair in the Bluetooth Setting of the smart phone. · · · · · CONTENT CONNECT TO CYCLING- COMPUTER AND SMART PHONE SLEEP MODE INSTALLATION CALIBRATION / ZERO RESET AXO2 or AXOcc2 Power Meter×1 Stickers×1 User Guide×1 Charging Cable×1(for AXO2) CR2032×1, Protective Cover×2(for AXOcc2) Thoroughly clean up the surface between the crank and spider till no grease or dust on it. Please install the spider to the crankarm according to the tightening torque marked on the spider. Please install the chainring to the spider according to the tightening torque printed on the chainring’s instruction book. After correctly install, use the power meter for 1 or 2 times, it would be accura…
Text truncated - open the document above for the full version.
Sigeyi Technology (Guangzhou) Co., Ltd. Agent Authorization Company: Sigeyi Technology (Guangzhou) Co., Ltd. Address: Room 202, Building #10, No.165, Dongguanzhuang Road, Tianhe District, Guangzhou City, Guangdong Province, China Product Name: AXO POWER METER Trade Mark: SIGEYI Model Number(s): PM016-AXOcc,PM016-AXO,PM016-AXOcc-SRAM-3-4- 110,PM016-AXOcc-SRAM-3-5-110,PM016-AXOcc-SRAM-8-4-110,PM016-AXOcc- SRAM-8-4-AXS107,PM016-AXOcc-SRAM-8-5-110,PM016-AXOcc-SRAM-MTB- BOOST-4-104,PM016-AXOcc-ROTOR-ALDHU-4-110,PM016-AXOcc-ROTOR- ALDHU-5-110,PM016-AXOcc-SHIMANO-MTB-4-104,PM016-AXOcc-SHIMANO-MTB- 8-100,PM016-AXOcc-CND-5-110,PM016-AXOcc-EASTON-4-110,PM016-AXOcc- EASTON-5-110,PM016-AXOcc-RF-MTB-BOOST-4-104,PM016-AXOcc-CND-MTB-AI- 4-104,PM016-AXOcc-EE-3-4-110,PM016-AXOcc-EE-3-5-110,PM016-AXO-SRAM-3-4- 110,PM016-AXO-SRAM-3-5-110,PM016-AXO-SRAM-8-4-110,PM016-AXO-SRAM-8-4- AXS107,PM016-AXO-SRAM-8-5-110,PM016-AXO-SRAM-MTB-BOOST-4-104,PM016- AXO-ROTOR-ALDHU-4-110,PM016-AXO-ROTOR-ALDHU-5-110,PM016-AXO- SHIMANO-MTB-4-104,PM016-AXO-SHIMANO-MTB-8-100,PM016-AXO-CND-5- 110,PM016-AXO-EASTON-4-110,PM016-AXO-EASTON-5-110,PM016-AXO-RF-MTB- BOOST-4-104,PM016-AXO-CND-MTB-AI-4-104,PM016-AXO-EE-3-4-110,PM016- AXO-EE-3-5-110 FCC ID: 2A7IN-PM016 We authorize MiCOM Labs Inc., 575 Boulder Court, Pleasanton, California 94566, USA, to act on our behalf on all matters concerning the certification of above named equipment. We declare that MiCOM Labs Inc. is allowed to forward all information related to the approval and certification of equipment to the regulatory agencies as required and to discuss any issues concerning the approval application. Any and all acts carried out by MiCOM Labs on our behalf shall have the same effect as acts of our own. Signature: Date: 2023-01-09 Name: Yunlong Li Title: General manager Company: Sigeyi Technology (Guangzhou) Co., Ltd.
Sigeyi Technology (Guangzhou) Co., Ltd. Add: Room 202, Building #10, No.165, Dongguanzhuang Road, Tianhe District, Guangzhou City, Guangdong Province, China Tel: 13169912481 Date: 2023-01-09 Dear Sir/Madam, We, Sigeyi Technology (Guangzhou) Co., Ltd. Hereby declares the following statement , PCB board, circuit, structure and internal of these model(s) are the same, Only model name is different for these model: Product Name: AXO POWER METER Trade Mark: SIGEYI Model Number(s): PM016-AXOcc,PM016-AXO,PM016-AXOcc-SRAM-3-4-110,PM016- AXOcc-SRAM-3-5-110,PM016-AXOcc-SRAM-8-4-110,PM016-AXOcc-SRAM-8-4- AXS107,PM016-AXOcc-SRAM-8-5-110,PM016-AXOcc-SRAM-MTB-BOOST-4- 104,PM016-AXOcc-ROTOR-ALDHU-4-110,PM016-AXOcc-ROTOR-ALDHU-5- 110,PM016-AXOcc-SHIMANO-MTB-4-104,PM016-AXOcc-SHIMANO-MTB-8- 100,PM016-AXOcc-CND-5-110,PM016-AXOcc-EASTON-4-110,PM016-AXOcc- EASTON-5-110,PM016-AXOcc-RF-MTB-BOOST-4-104,PM016-AXOcc-CND-MTB-AI-4- 104,PM016-AXOcc-EE-3-4-110,PM016-AXOcc-EE-3-5-110,PM016-AXO-SRAM-3-4- 110,PM016-AXO-SRAM-3-5-110,PM016-AXO-SRAM-8-4-110,PM016-AXO-SRAM-8-4- AXS107,PM016-AXO-SRAM-8-5-110,PM016-AXO-SRAM-MTB-BOOST-4-104,PM016- AXO-ROTOR-ALDHU-4-110,PM016-AXO-ROTOR-ALDHU-5-110,PM016-AXO- SHIMANO-MTB-4-104,PM016-AXO-SHIMANO-MTB-8-100,PM016-AXO-CND-5- 110,PM016-AXO-EASTON-4-110,PM016-AXO-EASTON-5-110,PM016-AXO-RF-MTB- BOOST-4-104,PM016-AXO-CND-MTB-AI-4-104,PM016-AXO-EE-3-4-110,PM016-AXO- EE-3-5-110 FCC ID: 2A7IN-PM016 Sincerely, Signature: Client’s name / title : Yunlong Li / General manager Contact information / address : Room 202, Building #10, No.165, Dongguanzhuang Road, Tianhe District, Guangzhou City, Guangdong Province, China Tel: 13169912481 E-Mail: [email protected]
Sigeyi Technology (Guangzhou) Co., Ltd. Office of Engineering Technology Federal Communications Commission 7435 Oakland Mills Road Columbia, MD 21046 USA Date: 2023-01-09 Subject; Request for Confidentiality FCC ID: 2A7IN-PM016 To Whom It May Concern, Pursuant to the provisions of the Commission’s rules Title 47 Sections §0.457 and §0.459, we are requesting the Commission to withhold the following attachment(s) as confidential documents from public disclosure indefinitely. These documents contain detailed system and equipment descriptions and are considered as proprietary information in operation of the equipment. The public disclosure of these documents might be harmful to our company and would give competitors an unfair advantage in the market. Schematic Diagram Block Diagram Operational Description In additional to above mentioned documents, in order to comply with the marketing regulations in Title 47 CFR §2.803 and the importation rules in Title 47 CFR §2.1204, while ensuring that business sensitive information remains confidential until the actual marketing of newly authorized devices, we request Short Term Confidentiality of the following attachment(s); External Photos Test Setup Photos Internal Photos User Manual For 45 days, pursuant to Public Notice DA 04-1705. OR For 180 days pursuant to KDB 726920 D01. It is our understanding that all measurement test reports, FCC ID label format and correspondence during the certification review process cannot be granted as confidential documents and this information will be available for public review once the grant of equipment authorization is issued. Sincerely, Signature: Name: Yunlong Li Title: General manager
Page 1 of 8 FCC ID: 2A7IN-PM016 IC: 28695-PM016 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity External Photos of the EUT Fig. 1 Fig. 2 Model:PM016-AXOcc Model: PM016-AXO Page 2 of 8 FCC ID: 2A7IN-PM016 IC: 28695-PM016 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Fig. 3 Fig. 4 Page 3 of 8 FCC ID: 2A7IN-PM016 IC: 28695-PM016 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Fig. 5 Fig. 6 Page 4 of 8 FCC ID: 2A7IN-PM016 IC: 28695-PM016 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Fig. 7 Fig. 8 Page 5 of 8 FCC ID: 2A7IN-PM016 IC: 28695-PM016 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Fig. 9 Fig. 10 Page 6 of 8 FCC ID: 2A7IN-PM016 IC: 28695-PM016 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Fig. 11 Fig. 12 Page 7 of 8 FCC ID: 2A7IN-PM016 IC: 28695-PM016 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Fig. 13 Fig. 14 Page 8 of 8 FCC ID: 2A7IN-PM016 IC: 28695-PM016 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Fig. 15 Fig. 16
Page 1 of 1 FCC ID: 2A7IN-PM016 IC: 28695-PM016 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Label and Location Size: L: 2.5cm*W: 1.5cm Label Location AXO POWER METER Model: PM016-AXOcc FCC ID: 2A7IN-PM016 IC: 28695-PM016
Page 1 of 4 FCC ID: 2A7IN-PM016 IC: 28695-PM016 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Internal Photos of the EUT Fig. 1 Fig. 2 Page 2 of 4 FCC ID: 2A7IN-PM016 IC: 28695-PM016 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Fig. 3 Fig. 4 Page 3 of 4 FCC ID: 2A7IN-PM016 IC: 28695-PM016 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Fig. 5 Fig. 6 Antenna Page 4 of 4 FCC ID: 2A7IN-PM016 IC: 28695-PM016 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Fig. 7
Page 1 of 4 FCC ID: 2A7IN-PM016 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity FCC RF Exposure Evaluation 1. Product Information FCC ID : 2A7IN-PM016 Product name : AXO POWER METER Test Model : PM016-AXOcc Additional Model No. : PM016-AXO,PM016-AXOcc-SRAM-3-4-110,PM016-AXOcc-SRA M-3-5-110,PM016-AXOcc-SRAM-8-4-110,PM016-AXOcc-SRAM- 8-4-AXS107,PM016-AXOcc-SRAM-8-5-110,PM016-AXOcc-SRA M-MTB-BOOST-4-104,PM016-AXOcc-ROTOR-ALDHU-4-110,PM 016-AXOcc-ROTOR-ALDHU-5-110,PM016-AXOcc-SHIMANO-M TB-4-104,PM016-AXOcc-SHIMANO-MTB-8-100,PM016-AXOcc- CND-5-110,PM016-AXOcc-EASTON-4-110,PM016-AXOcc-EAST ON-5-110,PM016-AXOcc-RF-MTB-BOOST-4-104,PM016-AXOcc -CND-MTB-AI-4-104,PM016-AXOcc-EE-3-4-110,PM016-AXOcc- EE-3-5-110,PM016-AXO-SRAM-3-4-110,PM016-AXO-SRAM-3-5- 110,PM016-AXO-SRAM-8-4-110,PM016-AXO-SRAM-8-4-AXS10 7,PM016-AXO-SRAM-8-5-110,PM016-AXO-SRAM-MTB-BOOST- 4-104,PM016-AXO-ROTOR-ALDHU-4-110,PM016-AXO-ROTOR- ALDHU-5-110,PM016-AXO-SHIMANO-MTB-4-104,PM016-AXO- SHIMANO-MTB-8-100,PM016-AXO-CND-5-110,PM016-AXO-EA STON-4-110,PM016-AXO-EASTON-5-110,PM016-AXO-RF-MTB- BOOST-4-104,PM016-AXO-CND-MTB-AI-4-104,PM016-AXO-EE -3-4-110,PM016-AXO-EE-3-5-110 Model Declaration : PCB board, structure and internal of these model(s) are the same, So no additional models were tested Power Supply : For PM016-AXOcc:3VDC by a button battery For PM016-AXO:Input: DC 5V,1A DC 3.7V by Rechargeable Li-ion Battery, 135mAh Bluetooth : 2402MHz ~ 2480MHz Channel Number : 40 channels for Bluetooth V5.0 (DTS) Channel Spacing : 2MHz for Bluetooth V5.0(DTS) Modulation Type : GFSK for Bluetooth V5.0 (DTS) Bluetooth Version : V5.0 Antenna Type : Ceramic Antenna Antenna Gain : 4.3dBi(Max.) Hardware version : PM_V3.0 Software version : PM_1.99_220608 Exposure category : General population/uncontrolled environment EUT Type : Production Unit Device Type : Portable Device Page 2 of 4 FCC ID: 2A7IN-PM016 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity 2. Evaluation method and Limit According to KDB447498 D01 General RF Exposure Guidance v06 Section 4.3.1 Standalone SAR test exclusion considerations: “Unless specifically required by the published RF exposure KDB procedures, standalone 1-g head or body and 10-g extremity SAR evaluation for general population exposure conditions, by measurement or numerical simulation, is not required when the corresponding SAR Test Exclusion Threshold condition, listed below, is satisfied. These test exclusion conditions are based on source-based time-averaged maximum conducted output power of the RF channel requiring evaluation, adjusted for tune-up tolerance, and the minimum test separation distance required for the exposure conditions.22 The minimum test separation distance is determined by the smallest distance from the antenna and radiating structures or outer surface of the device, according to the host form factor, exposure conditions and platform requirements, to any part of the body or extremity of a user or bystander (see 5) of section 4.1). To qualify for SAR test exclusion, the test separation distances applied must be fully explained and justified by the operating configurations and exposure conditions of the transmitter and applicable host platform requirements, typically in the SAR measurement or SAR analysis report, according to the required published RF exposure KDB procedures. When no other RF exposure testing or reporting is required, a statement of justification and compliance must be included in the equipment approval, in lieu of the SAR report, to qualify for the SAR test exclusion. When required, the device specific conditions described in the other published RF exposure KDB procedures must be satisfied before applying these SAR test exclusion provisions; for example, handheld PTT two-way radios, handsets, laptops & tablets etc.“ [(max. power of channel, including tune-up tolerance, mW)/ (min. test separation distance, mm)] · [√f (GHz)] ≤ 3.0 for 1-g SAR and ≤ 7.5 for 10-g extremity SAR, where: • f (GHz) is the RF channel transmit frequency in GHz • Power and distance are rounded to the nearest mW and mm before calculation • The result is rounded to one decimal place for comparison • 3.0 and 7.5 are referred to as the numeric thresholds in the step 2 below The test exclusions are applicable only when the minimum test separation distance is ≤ 50 mm and for transmission frequencies between 100 MHz and 6 GHz. When the minimum test separation distance is < 5 mm, a distance of 5 mm according to f) in section 4.1 is applied to determine SAR test exclusion. When one of the following test exclusion conditions is satisfied for all combinations of simultaneous transmission configurations, further equipment approval is not required to incorporate transmitter modules in host devices that operate in the mixed mobile and portable host platform exposure conditions. The grantee is responsible for documenting this according to Class I permissive change requirements. Antennas that qualify for standalone SAR test exclusion must apply the estimated standalone SAR to determine simultaneous transmission test exclusion. a) The [∑ of (the highest measured or estimated SAR for each standalone antenna configuration, adjusted for maximum tune-up tolerance) / 1.6 W/kg] + [∑ of MPE ratios] is ≤ 1.0. b)The SAR to peak location separation ratios of all simultaneously transmitting antenna pairs operating in portable device exposure conditions are all ≤ 0.04, and the [∑ of MPE ratios] is ≤ 1.0. 3. Refer Evaluation Method ANSI C95.1–1999: IEEE Standard for…
Text truncated - open the document above for the full version.
CA-C03 Specification CA-C03_V02 1 SMD ANT Specification CrossAir TM SMD T he antenna family comply to the RoHS specification PN: CA-C03 2.4 GHz ISM band ant CA-C03 Specification CA-C03_V02 2 characteristic 1.1. Small size SMD patch antenna measuring only 5.5 X 2.0 X 1.0 mm3. 2. Low energy loss and high antenna efficiency.3. High stability in the case of temperature and humidity changes. Apply 1.2.4GHz ISM Band antenna applications 2. Bluetooth, ZigBee, wireless applications, smart home applications, etc. 3. WIFI (only 2.4G) Structure 1, antenna feed terminal 2, feed identification mark 3, antenna welding fixed end Size Three views Symbol Size(mm) L 5.5±0.2 w 2.0±0.1 T 1.0±0.1 a 0.5±0.1 CA-C03 Specification CA-C03_V02 3 electrical character CA-C03 Specification 工作频率范围Working Frequency 2450±50MHz 初始频段(GHz) 2.7GHz 带宽Band Width >100MHz 阻抗Impedance 50Ω 增益Gain(dBi) 4.3(peak) 驻波比VSWR <2 工作温度Operation Temperature -40°C~+95°C 可承受功率Power Capacity 3W The antenna 2.4G operating frequency needs to be realized by impedance matching device debugging. Antenna welding pad and wire running design Design size diagram CA-C03 Specification CA-C03_V02 4 Matching device values Series 1 0Ω Shunt 1 3nh Series 2 0Ω Antenna test on test plate (plate thickness 1.0mm) CA-C03 Specification CA-C03_V02 5 Antenna S11 characteristics Antenna VSWR characteristics Efficiency and radiation diagram Efficiency, radiation map, gain and other properties are obtained based on the test plate design. The specification characteristics test data for the CA-C03 antenna is CA-C03 Specification CA-C03_V02 6 Based on the test PCB plate size and the test direction shown in the following below. The following data were tested in the ETS 3D microwave darkroom Gain and Efficiency Bandwidth 2.4G-2.5GHz 峰值增益Peak Gain 4.3dBi 带内平均增益 Average Gain across the band 4.1dBi 带内增益范围 Gain Range across the band 3.9dBi~4.3dBi 峰值效率Peak Efficiency 81.7% 带内平均效率 Average Efficiency across the band 80.2% 带内效率范围 Efficiency Range across the band 78.6%~81.7% Theta @2.45 GHz Z Y X CA-C03 Specification CA-C03_V02 7 Phi @2.45 GHz Total @2.45 GHz welding condition The reliable and nondestructive typical welding specifications are shown below: CA-C03 Specification CA-C03_V02 8 Package Plastic tape specifications (Unit:mm) Index Ao Bo ΦD T W Dimension (mm) 3.0±0.1 6.0±0.1 1.55±0.05 1.6±0.1 16±0.2 Index E F Po P1 P2 Dimension (mm) 1.75±0.1 7.0±0.1 4.0±0.1 4.0±0.1 2.0±0.1 Volume disc size CA-C03 Specification CA-C03_V02 9 Index A B C Dimension(mm) 330 100 13.5 Standard quantity: 3000 PCS / disk.
Page 1 of 39 FCC ID: 2A7IN-PM016 IC: 28695-PM016 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Appendix A RF Test Data for BLE (Conducted Measurement) Product Name: AXO POWER METER Test Model: PM016-AXOcc Environmental Conditions Temperature: 23.1 C Relative Humidity: 52.3% ATM Pressure: 100.0 kPa Test Engineer: Ling Zhu Supervised by: Li Huan Page 2 of 39 FCC ID: 2A7IN-PM016 IC: 28695-PM016 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity A.1 DTS Bandwidth Test Result TestMode Antenna Channel DTS BW [MHz] FL[MHz] FH[MHz] Limit[MHz] Verdict BLE_1M Ant 2402 0.704 2401.756 2402.460 0.5 PASS 2440 0.708 2439.756 2440.464 0.5 PASS 2480 0.712 2479.756 2480.468 0.5 PASS BLE_2M Ant 2402 1.152 2401.420 2402.572 0.5 PASS 2440 1.156 2439.420 2440.576 0.5 PASS 2480 1.156 2479.420 2480.576 0.5 PASS Page 3 of 39 FCC ID: 2A7IN-PM016 IC: 28695-PM016 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Test Graphs BLE_1M_Ant_2402 BLE_1M_Ant_2440 BLE_1M_Ant_2480 Page 4 of 39 FCC ID: 2A7IN-PM016 IC: 28695-PM016 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity BLE_2M_Ant_2402 BLE_2M_Ant_2440 Page 5 of 39 FCC ID: 2A7IN-PM016 IC: 28695-PM016 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity BLE_2M_Ant_2480 Page 6 of 39 FCC ID: 2A7IN-PM016 IC: 28695-PM016 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity A.2 Occupied Channel Bandwidth Test Result TestMode Antenna Channel OCB [MHz] FL[MHz] FH[MHz] Limit[MHz] Verdict BLE_1M Ant 2402 1.0610 2401.576 2402.637 --- --- 2440 1.0567 2439.578 2440.634 --- --- 2480 1.0697 2479.576 2480.646 --- --- BLE_2M Ant 2402 2.0672 2400.9787 2403.0459 --- --- 2440 2.0652 2438.9815 2441.0467 --- --- 2480 2.0694 2478.9774 2481.0468 --- --- Page 7 of 39 FCC ID: 2A7IN-PM016 IC: 28695-PM016 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Test Graphs BLE_1M_Ant_2402 BLE_1M_Ant_2440 BLE_1M_Ant_2480 Page 8 of 39 FCC ID: 2A7IN-PM016 IC: 28695-PM016 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity BLE_2M_Ant_2402 BLE_2M_Ant_2440 Page 9 of 39 FCC ID: 2A7IN-PM016 IC: 28695-PM016 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity BLE_2M_Ant_2480 Page 10 of 39 FCC ID: 2A7IN-PM016 IC: 28695-PM016 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity A.3 Maximum Conducted Output Power Test Result TestMode Antenna Channel Result[dBm] Limit[dBm] Verdict BLE_1M Ant 2402 0.28 ≤30 PASS 2440 -0.07 ≤30 PASS 2480 -0.01 ≤30 PASS BLE_2M Ant 2402 -1.52 ≤30 PASS 2440 -1.27 ≤30 PASS 2480 -1.22 ≤30 PASS Page 11 of 39 FCC ID: 2A7IN-PM016 IC: 28695-PM016 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Test Graphs BLE_1M_Ant_2402 BLE_1M_Ant_2440 BLE_1M_Ant_2480 Page 12 of 39 FCC ID: 2A7IN-PM016 IC: 28695-PM016 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District,…
Text truncated - open the document above for the full version.
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 2.40 GHz - 2.48 GHz | 1.10 mW |