Equipment Class
DCD - Part 15 Low Power Transmitter Below 1705 kHz
Date of Grant
Feb 06, 2026
Application Purpose
Original Equipment
Equipment Note
3 in 1 Foldable Wireless Charger
Frequency Range
0.11000000 - 0.20500000
Company
CG Mobile SAS
Country
France

Documents & Files

Select a file to view

Attestation Statements

↗

Cover Letter(s)

↗
↗
↗

External Photos

↗

ID Label/Location Info

↗

RF Exposure Info

↗

Test Report

↗
↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Attestation Statements

CG Mobile SAS (February 3, 2026) Eurofins Electrical and Electronic Testing NA, Inc. 914 West Patapsco Avenue Baltimore, MD 21230 RE: Attestation Statements Part 2.911(d)(5)(i) request for FCC ID: 2A7J2AK09M [CG Mobile SAS] (“the applicant”) certifies that the equipment for which authorization is sought is not “covered” equipment prohibited from receiving an equipment authorization pursuant to section 2.903 of the FCC rules. We also certify that, as of the date of the filing of the application, the equipment does not utilize cyber-security or anti-virus software from Kaspersky Lab, Inc, or any of its successors and assignees, which is also on the “covered list”. Sincerely, (Applicant signature) (Applicant printed name) Marc Azoulay CG Mobile SAS (February 3, 2026) Eurofins Electrical and Electronic Testing NA, Inc. 914 West Patapsco Avenue Baltimore, MD 21230 RE: Attestation Statements Part 2.911(d)(5)(ii) request for FCC ID: 2A7J2AK09M [CG Mobile SAS] (“the applicant”) certifies that, as of the date of the filing of the application, the applicant is not identified on the Covered List as an entity producing “covered” equipment. Sincerely, (Applicant signature) (Applicant printed name) Marc Azoulay

Cover Letter(s)

CG Mobile SAS Model Difference Data:February 3, 2026 Product description: 3 in 1 Foldable Wireless Charger Model name: AK09M, TUFWC15WAK09MCOO, TUFWC15WAK09A2, TUFWC15WAK09A3, TUFWC15WAK09A4, TUFWC15WAK09A5 Trade Name: N/A FCC ID: 2A7J2AK09M All the model are the same circuit and RF module, only the name is different. Regards Sincerely Client’s signature : Client’s name / title : Marc Azoulay(CEO) Contact information / address:39 rue de Courcelles Paris, 75008 France

Cover Letter(s)

CG Mobile SAS (February 3, 2026) Eurofins Electrical and Electronic Testing NA, Inc. 914 West Patapsco Avenue Baltimore, MD 21230 RE: CONFIDENTIALITY REQUEST FOR (3 in 1 Foldable Wireless Charger / AK09M, TUFWC15WAK09MCOO, TUFWC15WAK09A2, TUFWC15WAK09A3, TUFWC15WAK09A4, TUFWC15WAK09A5 / FCC ID: 2A7J2AK09M) To Whom It May Concern: This letter serves as an official request for confidentiality under sections 0.457 and 0.459 of CFR 47. We have requested that the Exhibits Long-Term Confidentiality Short-Term Confidentiality NOTE 2 ID Label/Location No No Attestation Statement No No External Photos No ☐ Block Diagram ☒ ☐ Schematics ☒ ☐ Test Report No No Test Setup Photos No ☐ User’s Manual ☐ NOTE 1 ☒ Internal Photos ☐ NOTE 1 ☒ Parts List / Tune Up ☐ ☐ RF Exposure Info No No Operational Description ☒ ☐ Cover Letter(s) No No SDR Software / Security Info ☐ No required to be submitted with this application be permanently withheld from public review. Above mentioned document contains detailed system and equipment description are considered as proprietary information in operation of the equipment. The public disclosure of above documents might be harmful to our company and would give competitor an unfair advantage in the market. Please contact me if there is any information you may need. Sincerely, Signature: Name: Marc Azoulay Title: CEO

Cover Letter(s)

CG Mobile SAS (February 3, 2026) Eurofins Electrical and Electronic Testing NA, Inc. 914 West Patapsco Avenue Baltimore, MD 21230 RE: LETTER OF AGENT AUTHORIZATION To Whom It May Concern: We, the undersigned, hereby authorize (Shenzhen CTB Testing Technology Co., Ltd.) to act on our behalf in all matters relating to application for equipment authorization, including the signing of all documents relating to these matters. We also hereby certify that no party to the application authorized hereunder is subject to the denial of benefits, including FCC benefits, pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C.853(a). This agreement expires one year from the current date. Sincerely, Signature: Name: Marc Azoulay Title: CEO

External Photos

Shenzhen CTB Testing Technology Co., Ltd. Report Tel: 4008-707-283 Web: http://www.ctb-lab.net Page 1 of 5 Model: AK09M External Photos Shenzhen CTB Testing Technology Co., Ltd. Report Tel: 4008-707-283 Web: http://www.ctb-lab.net Page 2 of 5 Shenzhen CTB Testing Technology Co., Ltd. Report Tel: 4008-707-283 Web: http://www.ctb-lab.net Page 3 of 5 Shenzhen CTB Testing Technology Co., Ltd. Report Tel: 4008-707-283 Web: http://www.ctb-lab.net Page 4 of 5 Shenzhen CTB Testing Technology Co., Ltd. Report Tel: 4008-707-283 Web: http://www.ctb-lab.net Page 5 of 5

ID Label/Location Info

FCC ID LABEL:

RF Exposure Info

Report Tel: 4008-707-283 Web: http://www.ctb-lab.net Page 1 of 16 RF EXPOSURE REPORT Compiled by: Reviewed by: Approved by: Kai Chen Martin Feng Bin Mei / Director Note: If there is any objection to the inspection results in this report, please submit a written report to the company within 15 days from the date of receiving the report. The test report is effective only with both signature and specialized stamp. This result(s) shown in this report refer only to the sample(s) tested. Without written approval of Shenzhen CTB Testing Technology Co., Ltd. this report can’t be reproduced except in full. The tested sample(s) and the sample information are provided by the client. “*” indicates the testing items were fulfilled by subcontracted lab. “#” indicates the items are not in CNAS accreditation scope. Test item description: 3 in 1 Foldable Wireless Charger FCC ID: 2A7J2AK09M Trademark(s): N/A Model/Type reference: AK09M, TUFWC15WAK09MCOO, TUFWC15WAK09A2, TUFWC15WAK09A3, TUFWC15WAK09A4, TUFWC15WAK09A5 Applicant’s name: CG Mobile SAS Address: 39 rue de Courcelles Paris, 75008 France Manufacturer: Dongguan Aosa electronic co., Ltd. Address: 3 floor, No.92, the Nanling Mountain Road, Youganpu Village, Fenggang Town, Dongguan City Prepared By: Shenzhen CTB Testing Technology Co., Ltd. Address: 1&2/F., Building A, No.26, Xinhe Road, Xinqiao, Xinqiao Street, Bao'an District, Shenzhen, Guangdong, China Sample Received Date: Jan. 07, 2026 Sample tested Date: Jan. 07, 2026 to Jan. 28, 2026 Issue Date: Jan. 28, 2026 Report No.: CTB26010703401RF02 Test Standards FCC CFR 47 part1, 1.1307(b), 1.1310, 47 CFR§2.1091; KDB 680106 D01 Wireless Power Transfer v04 Test Results PASS Remark: This is wireless charger EMF report. Shenzhen CTB Testing Technology Co., Ltd. Report No.: CTB26010703401RF02 EMF Report Te l : 4008-707-283 Web: http://www.ctb-lab.net Page2 of 16 Table of Contents Page 1 . GENERAL INFORMATION 3 1.1 . Independent Operation Mode 3 1.2 . Test Supporting System 3 2 .LIST OF T EST AND M EASUREMENT I NSTRUMENTS 4 2.1 . For conducted emission at the mains terminals test 4 3. METHOD OF MEASUREMENT 5 3. 1.Applicable Standard 5 4. TEST RESULT 6 4.1. Conducted Emission at the Mains Terminals Test 6 4.2. Equipment Approval Considerations: 7 4.3. E and H field Strength 8 Shenzhen CTB Testing Technology Co., Ltd. Report No.: CTB26010703401RF02 EMF Report Te l : 4008-707-283 Web: http://www.ctb-lab.net Page3 of 16 1. GENERAL INFORMATION 1.1. Independent Operation Mode The basic operation mode is: 1.1.1. wireless charger power: 3W/5W/7.5W/10W/15W 1.2. Te st Supporting System Adapter Description: Adapter Model No.: HP18A-0902000-AU Power Input: AC100-240V~ 1.0A 50/60Hz Output: 9V⎓2.0A DC Line: Unshielded, Detachable 1.2m Shenzhen CTB Testing Technology Co., Ltd. Report No.: CTB26010703401RF02 EMF Report Te l : 4008-707-283 Web: http://www.ctb-lab.net Page4 of 16 2.LIST OF T EST AND MEASUREMENT I NSTRUMENTS 2.1. For conducted emission at the mains terminals test Item Equipment Brand Model No. Serial No. Last calibration Calibrated until 1 EMF TESTER Wavecontrol SMP600/WP4 00-3 15SN0164/21W P1200029 2025/10/22 2026/10/21 Shenzhen CTB Testing Technology Co., Ltd. Report No.: CTB26010703401RF02 EMF Report Te l : 4008-707-283 Web: http://www.ctb-lab.net Page5 of 16 3. METHOD OF MEASUREMENT 3. 1.Applicable Standard According to §1.1307(b)(1), systems operating under the provisions of this section shall be operated in a manner that ensures that the public is not exposed to radio frequency energy level in excess of the Commission’s guidelines. According to §1.1310 and §2.1091 RF exposure is calculated. According KDB680106 D01: KDB 680106 D01 Wireless Power Transfer v04. Shenzhen CTB Testing Technology Co., Ltd. Report No.: CTB26010703401RF02 EMF Report Te l : 4008-707-283 Web: http://www.ctb-lab.net Page6 of 16 4. TEST RESULT 4.1. Conducted Emission at the Mains Terminals Test Note: Measurements should be made from all sides and the top of the primary/client pair, with the 20 cm measured from the center of the probe(s) to the edge of the device Test Procedure: a) The RF exposure test was performed on 360 degree turn table in anechoic chamber. b) The measurement probe was placed at test distance (20cm) which is between the edge of the charger and the geometric centre of probe. c) The turn table was rotated 360d degree to search of highest strength. d) The highest emission level was recorded and compared with limit as soon as measurement of each points were completed. e) The EUT were measured according to the dictates of KDB 680106v04 Shenzhen CTB Testing Technology Co., Ltd. Report No.: CTB26010703401RF02 EMF Report Te l : 4008-707-283 Web: http://www.ctb-lab.net Page7 of 16 4.2. Equipment Approval Considerations: The EUT does comply with item 5(b) of KDB 680106 V04 1) The power transfer frequency is below 1 MHz. Yes, the device operate in the frequency range from 110kHz to 205kHz, and 300kHz to 350kHz 2) The output power from each transmitting element (e.g., coil) is less than or equal to 15 watts. Yes, the maximum output power of the primary coil is 15000mW. 3) A client device providing the maximum permitted load is placed in physical contact with the transmitter (i.e., the surfaces of the transmitter and client device enclosures need to be in physical contact). Ye s , the surfaces of the transmitter and client device enclosures are in physical contact 4) Only § 2.1091-Mobile exposure conditions apply (i.e., this provision does not cover § 2.1093-Portable exposure conditions).. Yes, the EUT is a Mobile Wireless Charger 5) The E-field and H-field strengths, at and beyond 20 cm surrounding the device surface, are demonstrated to be less than 50% of the applicable MPE limit, per KDB 447498, Table 1. Yes, the EUT field strength levels are less 50% x MPE limit. 6) For systems with more than one radiating structure, the conditions specified in (5) must be met when the system is fully loaded (i.e., clients absorbing max…

Text truncated - open the document above for the full version.

Test Report

Report Tel: 4008-707-283 Web: http://www.ctb-lab.net Page 1 of 24 TEST REPORT Compiled by: Reviewed by: Approved by: Kai Chen Martin Feng Bin Mei / Director Note: If there is any objection to the inspection results in this report, please submit a written report to the company within 15 days from the date of receiving the report. The test report is effective only with both signature and specialized stamp. This result(s) shown in this report refer only to the sample(s) tested. Without written approval of Shenzhen CTB Testing Technology Co., Ltd. this report can’t be reproduced except in full. The tested sample(s) and the sample information are provided by the client. “*” indicates the testing items were fulfilled by subcontracted lab. “#” indicates the items are not in CNAS accreditation scope. Test item description: 3 in 1 Foldable Wireless Charger FCC ID: 2A7J2AK09M Trademark(s): N/A Model/Type reference: AK09M, TUFWC15WAK09MCOO, TUFWC15WAK09A2, TUFWC15WAK09A3, TUFWC15WAK09A4, TUFWC15WAK09A5 Applicant’s name: CG Mobile SAS Address: 39 rue de Courcelles Paris, 75008 France Manufacturer: Dongguan Aosa electronic co., Ltd. Address: 3 floor, No.92, the Nanling Mountain Road, Youganpu Village, Fenggang Town, Dongguan City Prepared By: Shenzhen CTB Testing Technology Co., Ltd. Address: 1&2/F., Building A, No.26, Xinhe Road, Xinqiao, Xinqiao Street, Bao'an District, Shenzhen, Guangdong, China Sample Received Date: Jan. 07, 2026 Sample tested Date: Jan. 07, 2026 to Jan. 28, 2026 Issue Date: Jan. 28, 2026 Report No.: CTB26010703401RF01 Test Standards FCC Part 15 C Test Results PASS Remark: This is wireless charger radio test report. Shenzhen CTB Testing Technology Co., Ltd. Report No.: CTB26010703401RF01 Report Tel: 4008-707-283 Web: http://www.ctb-lab.net Page 2 of 24 TABLE OF CONTENTS 1.GENERAL INFORMATION ........................................................................................................................ 3 1.1. Report information ................................................................................................................................. 3 1.2. Measurement Uncertainty ..................................................................................................................... 3 1.3. Test Facility ........................................................................................................................................... 3 1.4. Test Uncertainty .................................................................................................................................... 4 2. PRODUCT DESCRIPTION ......................................................................................................................... 5 2.1. EUT Description .................................................................................................................................... 5 2.2. Block Diagram of EUT Configuration ..................................................................................................... 5 2.3. Test Conditions ..................................................................................................................................... 5 2.4. DescriptionOfSupport Units (Conducted Mode) .................................................................................... 6 3. TEST RESULTS SUMMARY ...................................................................................................................... 7 4. TEST EQUIPMENT USED .......................................................................................................................... 8 4.1. MEASUREMENT INSTRUMENTS LIST ............................................................................................... 8 5. CONDUCTED EMISSION TEST ............................................................................................................... 11 5.1. Block Diagram of Test Setup ............................................................................................................... 11 5.2. Test Standard ...................................................................................................................................... 11 5.3. Conducted Emission Limit ................................................................................................................... 11 5.4. EUT Configuration on Test .................................................................................................................. 11 5.5. Operating Condition of EUT ................................................................................................................ 11 5.6. Test Procedure .................................................................................................................................... 12 5.7. Test Result .......................................................................................................................................... 12 6. RADIATED EMISSION MEASUREMENT ................................................................................................ 15 6.1. Block Diagram of Test Setup ............................................................................................................... 15 6.2. Test Standard ...................................................................................................................................... 16 6.3. EMI Test Receiver Setup..................................................................................................................... 16 6.4. Test Procedure .................................................................................................................................... 16 6.5. Test Result .......................................................................................................................................... 16 7. OCCUPIED BANDWIDTH ........................................................................................................................ 20 7.…

Text truncated - open the document above for the full version.

Test Report

广东省东莞市石碣镇新风西路号B栋楼 th Floor, Building B, No.  Xinfeng West Road, Shijie Town, Dongguan City, Guangdong Province Notes: .Attach the coil to the round hard magnet. The magnetic sheet has a hole and double slots. .Wrap mm high-temperature tape around the wire outlet position of the coil. Apply white adhesive tape with tabs to the Apply white adhesive tape with tabs to the back side of the film. .The coil wires must not be loose.

Contact Information

Applicant

Marc Azoulay(CEO)
[email protected]Fax: 330183646574

Technical Contact

GLOCERTS TECHNOLOGY INCHuiying Fan
[email protected]

19784 SUNKISSED RIDGE DR, · RIVERSIDE,, California, 92507 · United States

Test Firm

Shenzhen CTB Testing Technology Co., Ltd.Rita Xiao
[email protected]

Technical Specifications

#Rule PartsFrequency RangePower Output
115C0.11 MHz - 0.205 MHz-
215C0.3 MHz - 0.35 MHz-
Confidentiality
Long Term
Grant Notes
The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter device.