FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Xiamen Vienatone Medical Technology Co., Ltd./
  3. 2A7JZ-002

2A7JZ-002Sound amplifier

Xiamen Vienatone Medical Technology Co., Ltd.
Sound amplifier - FCC ID 2A7JZ-002 - Xiamen Vienatone Medical Technology Co., Ltd.
Click to zoom

Application Details

Equipment Class
DTS - Digital Transmission System
Date of Grant
Jul 31, 2023
Application Purpose
Original Equipment
Date of Application
Jul 31, 2023
Equipment Note
Sound amplifier
Frequency Range
2402.00000000 - 2480.00000000
Company
Xiamen Vienatone Medical Technology Co., Ltd.
Country
China

Documents & Files

Select a file to view

Users Manual

↗

Attestation Statements

↗
↗

Cover Letter(s)

↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗
↗
↗
↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

FC-BLE-RIC User Manual Please read this user manual thoroughly and completely before using the product. Version: 102022 1.【HOW TO USE HEARING AID】 2.【QUICK GUIDE】 3.【HA-Fit APP】 4.【BLUETOOTH CONNECTION】 5.【CHARGING】 .....................6 ...................6 ...........3 .................................6 ..................................10 ....................13 ..................................16 ...............18 ............................18 ..............19 .............20 ..........................20 .......................21 I. IMPORTANT SAFETY INSTRUCTIONS CONTENTS II. HOW TO USE YOUR DEVICE III. REPLACEMENT ACCESSORIES IV. MAINTENANCE AND CLEANING 1.【Daily maintenance】 2.【Care and maintenance】 1. 【Change earbuds】 2. 【Wax guard Replacement Guide】 -1- Please download and install “HA-Fit” APP first. .....................................21 ...............................27 .....................................28 ..................28 ..........................22 .................23 ..................26 Read all the information in this instruction manual and any other literature included in the box before using the device. The device should not be used in the following situations: - Patients with chronic suppurative otitis media (CSOM),congenital ear atresia, or any type of ear discharge 1. CONTRAINDICATION V. HEARING AIDS CARE VI. TROUBLESHOOTING GUIDE VII.TECHNICAL SPECIFICATION VIII. DO NOT USE IF ANY OF THE FOLLOWING APPLY TO YOU: IX. MATTERS NEEDING ATTENTION, WARNING AND TIPS X. FCC WARNING STATEMENT - Keep small parts (hearing instrument, ear domes, battery or other detachable parts) that can be swallowed out of children's reach. Dropping, immersing in liquid, exposure to strong electromagnetic fields or excessive heat will damage the hearing aids. Remove devices prior to any type of X-ray, MRI, or CT scan. If parts become stuck in the ear canal, seek medical assistance - do not attempt to remove by yourself. 2. WARNINGS Warning I. IMPORTANT SAFETY INSTRUCTIONS 3.【Cleaning】 -3- - Do not use at high volume for extended periods of time-ear injury can result. - If you experience any pain or strong discomfort using the devices, remove and consult a doctor. 2. Notice Warning -4--5- - Routine maintenance to keep the device clean is required. Ensure that ear domes are free of debris and moisture at all times. - Avoid shocks or dropping the product. - Do not store or use the product in environments of high humidity or temperature (such as sauna room), to avoid damage. - Batteries should be properly recycled and not disposed in the trash. - Keep the devices away from small children. Injury or damage may result. - Do not set volume levels too high. Listening with high-output devices for extended periods at high volume levels can cause further hearing damage. - Do not share your hearing aids with others. Using a hearing aid configured for someone else can result in hearing damage or injury. - Monitor for any unusual skin reaction. If you notice any allergic reaction (itchiness, swelling, or rash), stop wearing the hearing aids and consult a medical specialist. - Do not touch the hearing aids to any type magnet or magnetized object. Your hearing aids are delicate electronic instruments and may be damaged by contact with strong magnetic fields. - Do not attempt to open or repair the devices yourself. Damage can result and will void the warranty. - Do not store your devices in a hot/humid locations. You should never leave your hearing aids near heating appllances or in direct sunlight. - Do not leave your hearing aids in the car as InsiIde temperatures can reach dangerous levels which could damage the devices. 1.【HOW TO USE HEARING AID】 2.【QUICK GUIDE】 II. HOW TO USE YOUR DEVICE -6--7- 1. Front-end microphone 2. Back-end microphone 3. multi-function button 4. Sound tube 5. Earplugs 6. Receiver 7. Charging contact point 1 2 4 7 5 6 3 2.1 ON/OFF • Long press for about 3 seconds to turn on. 2.2 Volume Adjustment • Long press for about 6 seconds to turn off the power. The hearing aids enter into hearing aid mode automatically after being turned on. Click the hearing aid button once: increase the volume one level. There are 10 volume levels, and when you hear two beeps, this is the highest volume level. Memory function:Restart the hearing aid and it will automatically restore to the volume level and the scene mode set last time. 2.3 Hearing Mode Change You can cycle through the 3 Hearing Mode by : long press button Hearing Mode Change 1 2 3 1 beep ("beep") 2 beeps ("beep beep") 3 beeps ("beep beep beep") General Hearing Mode Noise Reduction Hearing Mode Outdoor Hearing Mode Sound you will hear when activatedHearing Mode R R R R -8--9- Please download and install “HA-Fit” APP first. 3.【HA-Fit APP】 3.1 HA-Fit app connects to hearing aids Please turn on the hearing aid. Be sure Bluetooth is enabied on your phone. Open the “HA-Fit” APP. Click the “Searching for Devices” button. 2.4 How To Wear It Step 1: Choose a suitable size ear dome, install in receiver tail. Step 2: Gently insert the earplug into the ear canal. Step 3: Place the hearing aid behind the ear. The curve of the sound tube should fit comfortably on top of your ear. Step 4: If the earplug isn't suitable, there will be gaps, which will cause whistling. Please again choose the suitable earplugs that fit your ear canal.  Step 1: Step 2: Step 3: Step 4: 3.2 Sound Control The HA-Fit app is designed to allow you to conveniently control your hearing aids remotely from your Android or Apple device at hand. HA-Fit app covers key features like changing programs 3.2 Hearing Evalution With the Hearing Hearing Evalution module, you can quickly set up your hearing aids according to your hearing characteristics. Please put on your hearing aids and turn them on. Please do the evalution in a quiet place. Click the “Hearing Evalution” button. After completing your hearing evalution, click the Auto- Optimize button and your hearing aids wi…

Text truncated - open the document above for the full version.

Attestation Statements

* theapplicantmustdesignateacontactlocatedintheUnitedStatesforpurposesofactingasthe applicant’sagentforserviceofprocess,regardlessofwhethertheapplicantisadomesticorforeign entity.AnapplicantlocatedintheUnitedStatesmaydesignateitselfastheagentforserviceofprocess. XiamenWenatoneMedicalTechnologyCo.,Ltd DATE TO:FederalCommunicationsCommission 7435OaklandMillsRoad Columbia,MD21046 ATTN.:ReviewingEngineer FCCID:2A7JZ-002 FRNofapplicant:0032570566 Persection2.911(d)(7)oftheFCCrules,[XiamenWenatoneMedicalTechnologyCo.,Ltd.] (“theapplicant”)certifiesthattheequipmentforwhichauthorizationissoughtisdesignatedto thefollowingU.S.agent*forserviceofprocess: CompanyName:WENATONELLC FCCRegistrationNumber(FRN):0034047936 PhysicalU.S.CompanyAddress:138RiverviewAvenue,Longmeadow,MA,USA ContactPerson:LeoLiu AgentEmailAddress:[email protected] Theabovecontactpersonacceptstheobligationforserviceofprocess. Theapplicantacceptstomaintainanagentfornolessthanoneyearafterthegranteehas terminatedallmarketingandimportationortheconclusionofanyCommission-related proceedinginvolvingtheequipment. ApplicantSigned: Printedname:yongquanliu Signed: Title:GeneralMANAGER CompanyName:XiamenWenatoneMedical TechnologyCo.,Ltd. Date:June9,2023 AgentSigned(ifdifferentfromApplicant): Printedname: LeoLiu Signed: Title:GeneralMANAGER CompanyName:WENATONELLC Date:June9,2023

Attestation Statements

XiamenWenatoneMedicalTechnologyCo.,Ltd. CoveredEquipmentCertificationAttestationLetter DATE2023/7/1 FederalCommunicationsCommission AuthorizationandEvaluationDivision 7435OaklandMillsRoad Columbia,MD21046 USA ATTN.:ReviewingEngineer FCCID:2A7JZ-002 XiamenWenatoneMedicalTechnologyCo.,Ltd.(“theapplicant”)certifiesthatthe equipmentforwhichauthorizationissoughtisnot“covered”equipmentprohibitedfrom receivinganequipmentauthorizationpursuanttosection2.903oftheFCCrules. Note:Iftheequipmentforwhichtheapplicantseeksauthorizationisproducedby anyoftheentitiesidentifiedonthecurrentCoveredList,theapplicantshould includeanexplanationonwhytheequipmentisnot“covered”equipment. XiamenWenatoneMedicalTechnologyCo.,Ltd.(“theapplicant”)certifiesthat,as ofthedateofthefilingoftheapplication,theapplicantisnotidentifiedontheCovered Listasanentityproducing“covered”equipment. Signed: Printedname:YongQuanLiu Title:GeneralMANAGER CompanyName:XiamenWenatoneMedicalTechnologyCo.,Ltd. Date:2023/7/1

Cover Letter(s)

DATE:2023/7/1 FederalCommunicationsCommission Authorization&EvaluationDivision 7345OaklandMillsRoad Columbia,Maryland21046 AuthoritytoActasAgent Onourbehalf,IappointBlueAsiaofTechnicalServices(Shenzhen)Co.,Ltd./BuildingC, No.107,ShihuanRoad,ShiyanSub-DistrictBaoanDistrict,Shenzhen,Guangdong Province,China(NameofAgentcompanynameandaddress)toactasouragentinthe preparationofthisapplicationforequipmentcertification.Icertifythatsubmitted documentsproperlydescribethedeviceorsystemforwhichequipmentcertificationis sought.Ialsocertifythateachunitmanufactured,importedormarketed,asdefinedinthe FederalCommunicationsCommission’sregulationswillhaveaffixedtoitalabelidentical tothatsubmittedforapprovalwiththisapplication. Forinstanceswhereourauthorizedagentsignstheapplicationforcertificationonour behalf,Iacknowledgethatallresponsibilityforcomplyingwiththetermsandconditions forcertification,stillresideswithXiamenWenatoneMedicalTechnologyCo.,Ltd. /805A,Jianyebuilding,Torchhi-Tech , (XiangAn)industrialpark , Xiamen , China(ApplicantNameandaddress) <Signature> Name:YongQuanLiu Title : GeneralMANAGER Company : XiamenWenatoneMedicalTechnologyCo.,Ltd.

Cover Letter(s)

DATE2023/7/1 EquipmentAutorisationDivision FederalCommunicationsCommission 7435OaklandMillsRoad Columbia,MD21046 FCCID:_2A7JZ-002__ ProductName:_Soundamplifier___ RequestforConfidentiality PursuanttoSections0.457and0.459ofthecommission’srules,weherebyrequestthat thefollowingdocumentsbeheldconfidential: (Listherethedocumentsforwhichyouareseekingconfidentiality–forexample...) Schematics Blockdiagram  Operationdescription Thesematerialscontaintradesecretsandproprietaryinformationandarenot customarilyreleasedtothepublic.Thepublicdisclosureofthisinformationmightbe harmfultothecompanyandprovideunjustifiedbenefitstoourcompetitors. <Signature> Name:YongQuanLiu Title:GeneralMANAGER Company:XiamenWenatoneMedicalTechnologyCo.,Ltd.

External Photos

ModelNo.: discoveryCR430SB+

ID Label/Location Info

Label: Soundamplifier ProductmodeldiscoveryCR430SB+Inputvoltage5v InputCurrent30mAInputpower0.15W FCCID2A7JZ-002 Manufacturer : XiamenWenatoneMedicalTechnologyCo.,Ltd. Address:805A,Jianyebuilding,Torchhi-Tech(XiangAn)industrialpark,Xiamen,Fujian, China Labellocation

Internal Photos

ModelNo.: discoveryCR430SB+

RF Exposure Info

RFExposureevaluation FCCID : 2A7JZ-002 Accordingto447498D04InterimGeneralRFExposureGuidancev01 Antgain=2.7dBi MaxOutputpower=-0.729dBm@EDR@2402MHz ERP=-0.729dBm+2.7dBi-2.15=-0.179dBm So worsecase : 10^-0.0179=0.960mW<2.79mW ComplywithRFexposureexemptionlimit.

Test Report

Page 1 of 60 BlueAsiaofTechnicalServices(Shenzhen)Co.,Ltd. Add:BuildingC,No.107,ShihuanRoad,ShiyanSub-District,BaoanDistrict,Shenzhen,GuangdongProvince,China Tel:+86-755-23059481Email:[email protected] TESTREPORT ProductName: Soundamplifier BrandMark: N/A ModelNo.: discoveryCR430SB+ FCCID: 2A7JZ-002 ReportNumber: BLA-EMC-202306-A4603 DateofSampleReceipt: 2023/6/12 DateofTest: 2023/6/15to2023/6/27 DateofIssue: 2023/6/28 TestStandard: 47CFRPart15,SubpartC15.247 TestResult:Pass Preparedfor: XiamenWenatoneMedicalTechnologyCo.,Ltd. 805A,Jianyebuilding,Torchhi-Tech(XiangAn)industrialpark,Xiamen, Fujian,China Preparedby: BlueAsiaofTechnicalServices(Shenzhen)Co.,Ltd. BuildingC,No.107,ShihuanRoad,ShiyanSub-District,BaoanDistrict, Shenzhen,GuangdongProvince,China TEL:+86-755-23059481 Compiledby:Reviewby: Approvedby:Date:2023/6/28 ReportNo.:BLA-EMC-202306-A4603 Page 2 of 60 BlueAsiaofTechnicalServices(Shenzhen)Co.,Ltd.Tel:+86-755-23059481Email:[email protected] REPORTREVISERECORD VersionNo.DateDescription 002023/6/28Original ReportNo.:BLA-EMC-202306-A4603 Page 3 of 60 BlueAsiaofTechnicalServices(Shenzhen)Co.,Ltd.Tel:+86-755-23059481Email:[email protected] TABLEOFCONTENTS 1TESTSUMMARY..............................................................................................................................................5 2GENERALINFORMATION...............................................................................................................................6 3GENERALDESCRIPTIONOFE.U.T................................................................................................................6 4TESTENVIRONMENT......................................................................................................................................7 5TESTMODE......................................................................................................................................................7 6MEASUREMENTUNCERTAINTY....................................................................................................................7 7DESCRIPTIONOFSUPPORTUNIT................................................................................................................8 8LABORATORYLOCATION..............................................................................................................................8 9TESTINSTRUMENTSLIST..............................................................................................................................9 10CONDUCTEDEMISSIONSATACPOWERLINE(150KHZ-30MHZ).........................................................11 10.1LIMITS......................................................................................................................................................................11 10.2BLOCKDIAGRAMOFTESTSETUP............................................................................................................................11 10.3PROCEDURE.............................................................................................................................................................11 10.4TESTDATA..................................................................................................................................................................13 11CONDUCTEDBANDEDGESMEASUREMENT.........................................................................................15 11.1LIMITS......................................................................................................................................................................15 11.2BLOCKDIAGRAMOFTESTSETUP............................................................................................................................15 11.3TESTDATA..................................................................................................................................................................16 12RADIATEDSPURIOUSEMISSIONS...........................................................................................................17 12.1LIMITS......................................................................................................................................................................17 12.2BLOCKDIAGRAMOFTESTSETUP............................................................................................................................18 12.3PROCEDURE.............................................................................................................................................................18 12.4TESTDATA..................................................................................................................................................................20 13ANTENNAREQUIREMENT..........................................................................................................................28 13.1CONCLUSION...............................................................................................................................................................28 14RADIATEDEMISSIONSWHICHFALLINTHERESTRICTEDBANDS.....................................................29 14.1LIMITS......................................................................................................................................................................29 14.2BLOCKDIAGRAMOFTESTSETUP............................................................................................................................30 14.3PROCEDURE.............................................................................................................................................................30 14.4TESTDATA..................................................................................................................................................................32 ReportNo.:BLA-EMC-202306-A4603 Page 4 of 60 BlueAsiaofTechnicalServic…

Text truncated - open the document above for the full version.

Test Report

ReportNo.:BLA-EMC-202306-A4603 Page 21 of 60 BlueAsiaofTechnicalServices(Shenzhen)Co.,Ltd.Tel:+86-755-23059481Email:[email protected] [TestMode:TX];[Polarity:Vertical] TestResult:Pass ReportNo.:BLA-EMC-202306-A4603 Page 22 of 60 BlueAsiaofTechnicalServices(Shenzhen)Co.,Ltd.Tel:+86-755-23059481Email:[email protected] Above1GHz: [TestMode:TXlowchannel];[Polarity:Horizontal] TestResult:Pass ReportNo.:BLA-EMC-202306-A4603 Page 23 of 60 BlueAsiaofTechnicalServices(Shenzhen)Co.,Ltd.Tel:+86-755-23059481Email:[email protected] [TestMode:TXlowchannel];[Polarity:Vertical] TestResult:Pass ReportNo.:BLA-EMC-202306-A4603 Page 24 of 60 BlueAsiaofTechnicalServices(Shenzhen)Co.,Ltd.Tel:+86-755-23059481Email:[email protected] [TestMode:TXmiddlechannel];[Polarity:Horizontal] TestResult:Pass ReportNo.:BLA-EMC-202306-A4603 Page 25 of 60 BlueAsiaofTechnicalServices(Shenzhen)Co.,Ltd.Tel:+86-755-23059481Email:[email protected] [TestMode:TXmiddlechannel];[Polarity:Vertical] TestResult:Pass ReportNo.:BLA-EMC-202306-A4603 Page 26 of 60 BlueAsiaofTechnicalServices(Shenzhen)Co.,Ltd.Tel:+86-755-23059481Email:[email protected] [TestMode:TXHighchannel];[Polarity:Horizontal] TestResult:Pass ReportNo.:BLA-EMC-202306-A4603 Page 27 of 60 BlueAsiaofTechnicalServices(Shenzhen)Co.,Ltd.Tel:+86-755-23059481Email:[email protected] [TestMode:TXHighchannel];[Polarity:Vertical] TestResult:Pass ReportNo.:BLA-EMC-202306-A4603 Page 28 of 60 BlueAsiaofTechnicalServices(Shenzhen)Co.,Ltd.Tel:+86-755-23059481Email:[email protected] 13ANTENNAREQUIREMENT TestStandard47CFRPart15,SubpartC15.247 TestMethodN/A 13.1CONCLUSION StandardRequirement: Anintentionalradiatorshallbedesignedtoensurethatnoantennaotherthanthatfurnished bytheresponsiblepartyshallbeusedwiththedevice.Theuseofaantennathatusesa uniquecouplingtotheintentionalradiator,themanufacturermaydesigntheunit permanentlyattachedantennaorofansothatabrokenantennacanbereplacedbythe user,buttheuseofastandardantennajackorelectricalconnectorisprohibited. EUTAntenna: TheantennaisintegratedonthemainPCBandnoconsiderationofreplacement.Thebest casegainoftheantennais2.7dBi. ReportNo.:BLA-EMC-202306-A4603 Page 29 of 60 BlueAsiaofTechnicalServices(Shenzhen)Co.,Ltd.Tel:+86-755-23059481Email:[email protected] 14RADIATEDEMISSIONSWHICHFALLINTHERESTRICTEDBANDS TestStandard47CFRPart15,SubpartC15.247 TestMethodANSIC63.10(2013)Section6.10.5 TestMode(Pre-Scan)TX TestMode(FinalTest)TX TesterCharlie Temperature25°C Humidity60% 14.1LIMITS Frequency(MHz) Field strength(microvolts/meter) Measurement distance(meters) 0.009-0.4902400/F(kHz)300 0.490-1.70524000/F(kHz)30 1.705-30.03030 30-881003 88-2161503 216-9602003 Above9605003 Remark:Theemissionlimitsshownintheabovetablearebasedonmeasurementsemployinga CISPRquasi-peakdetectorexceptforthefrequencybands9-90kHz,110-490kHzandabove1000 MHz.Radiatedemissionlimitsinthesethreebandsarebasedonmeasurementsemployingan averagedetector,thepeakfieldstrengthofanyemissionshallnotexceedthemaximumpermitted averagelimitsspecifiedabovebymorethan20dBunderanyconditionofmodulation. ReportNo.:BLA-EMC-202306-A4603 Page 30 of 60 BlueAsiaofTechnicalServices(Shenzhen)Co.,Ltd.Tel:+86-755-23059481Email:[email protected] 14.2BLOCKDIAGRAMOFTESTSETUP 14.3PROCEDURE a.Forbelow1GHz,theEUTwasplacedonthetopofarotatingtable0.8metersabovethegroundata3 or10metersemi-anechoicchamber.Thetablewasrotated360degreestodeterminethepositionofthe highestradiation. b.Forabove1GHz,theEUTwasplacedonthetopofarotatingtable1.5metersabovethegroundata3 meterfully-anechoicchamber.Thetablewasrotated360degreestodeterminethepositionofthehighest radiation. c.TheEUTwasset3or10metersawayfromtheinterference-receivingantenna,whichwasmountedon thetopofavariable-heightantennatower. d.Theantennaheightisvariedfromonemetertofourmetersabovethegroundtodeterminethe maximumvalueofthefieldstrength.Bothhorizontalandverticalpolarizationsoftheantennaaresetto makethemeasurement. e.Foreachsuspectedemission,theEUTwasarrangedtoitsworstcaseandthentheantennawastuned toheightsfrom1meterto4meters(forthetestfrequencyofbelow30MHz,theantennawastunedto heights1meter)andtherotatabletablewasturnedfrom0degreesto360degreestofindthemaximum reading. f.Thetest-receiversystemwassettoPeakDetectFunctionandSpecifiedBandwidthwithMaximumHold Mode. g.IftheemissionleveloftheEUTinpeakmodewas10dBlowerthanthelimitspecified,thentesting couldbestoppedandthepeakvaluesoftheEUTwouldbereported.Otherwisetheemissionsthatdidnot have10dBmarginwouldbere-testedonebyoneusingpeak,quasi-peakoraveragemethodasspecified andthenreportedinadatasheet. ReportNo.:BLA-EMC-202306-A4603 Page 31 of 60 BlueAsiaofTechnicalServices(Shenzhen)Co.,Ltd.Tel:+86-755-23059481Email:[email protected] h.TesttheEUTinthelowestchannel,themiddlechannel,theHighestchannel. i.TheradiationmeasurementsareperformedinX,Y,ZaxispositioningforTransmittingmode,andfound theXaxispositioningwhichitistheworstcase. j.Repeataboveproceduresuntilallfrequenciesmeasuredwascomplete. Remark1:Level=ReadLevel+CableLoss+AntennaFactor-PreampFactor Remark2:Forfrequenciesabove1GHz,thefieldstrengthlimitsarebasedonaveragelimits.However, thepeakfieldstrengthofanyemissionshallnotexceedthemaximumpermittedaveragelimitsspecified abovebymorethan20dBunderanyconditionofmodulation.Fortheemissionswhosepeaklevelis lowerthantheaveragelimit,onlythepeakmeasurementisshowninthereport. ReportNo.:BLA-EMC-202306-A4603 Page 32 of 60 BlueAsiaofTechnicalServices(Shenzhen)Co.,Ltd.Tel:+86-755-23059481Email:[email protected] 14.4TESTDATA [TestMode:TXlowchannel];[Polarity:Horizontal] TestResult:Pass ReportNo.:BLA-EMC-202306-A4603 Page 33 of 60 BlueAsiaofTechnicalServices(Shenzhen)Co.,Ltd.Tel:+86-755-23059481Email:[email protected] [TestMode:TXlowchannel];[Polarity:Vertical] TestRes…

Text truncated - open the document above for the full version.

Test Report

ReportNo.:BLA-EMC-202306-A4603 Page 41 of 60 BlueAsiaofTechnicalServices(Shenzhen)Co.,Ltd.Tel:+86-755-23059481Email:[email protected] 18MINIMUM6DBBANDWIDTH TestStandard47CFRPart15,SubpartC15.247 TestMethodANSIC63.10(2013)Section11.8.1 TestMode(Pre-Scan)TX TestMode(FinalTest)TX TesterCharlie Temperature25°C Humidity60% 18.1LIMITS Limit:≥500kHz 18.2BLOCKDIAGRAMOFTESTSETUP 18.3TESTDATA Pass:PleaseReferToAppendix:Appendix1ForDetails ReportNo.:BLA-EMC-202306-A4603 Page 42 of 60 BlueAsiaofTechnicalServices(Shenzhen)Co.,Ltd.Tel:+86-755-23059481Email:[email protected] 19APPENDIX Appendix1 19.1MAXIMUMCONDUCTEDOUTPUTPOWER ConditionModeFrequency (MHz) AntennaConductedPower (dBm) Limit (dBm) Verdict NVNTBLE1M2402Ant1-2.18630Pass NVNTBLE1M2442Ant1-5.28330Pass NVNTBLE1M2480Ant1-7.94130Pass PowerNVNTBLE1M2402MHzAnt1 PowerNVNTBLE1M2442MHzAnt1 ReportNo.:BLA-EMC-202306-A4603 Page 43 of 60 BlueAsiaofTechnicalServices(Shenzhen)Co.,Ltd.Tel:+86-755-23059481Email:[email protected] PowerNVNTBLE1M2480MHzAnt1 ReportNo.:BLA-EMC-202306-A4603 Page 44 of 60 BlueAsiaofTechnicalServices(Shenzhen)Co.,Ltd.Tel:+86-755-23059481Email:[email protected] 19.2-6DBBANDWIDTH ConditionModeFrequenc y(MHz) Antenna-6dBBandwidth (MHz) Limit-6dB Bandwidth(MHz) Verdict NVNTBLE1M2402Ant10.7050.5Pass NVNTBLE1M2442Ant10.6820.5Pass NVNTBLE1M2480Ant10.6870.5Pass -6dBBandwidthNVNTBLE1M2402MHzAnt1 -6dBBandwidthNVNTBLE1M2442MHzAnt1 ReportNo.:BLA-EMC-202306-A4603 Page 45 of 60 BlueAsiaofTechnicalServices(Shenzhen)Co.,Ltd.Tel:+86-755-23059481Email:[email protected] -6dBBandwidthNVNTBLE1M2480MHzAnt1 ReportNo.:BLA-EMC-202306-A4603 Page 46 of 60 BlueAsiaofTechnicalServices(Shenzhen)Co.,Ltd.Tel:+86-755-23059481Email:[email protected] 19.3OCCUPIEDCHANNELBANDWIDTH ConditionModeFrequency(MHz)Antenna99%OBW(MHz) NVNTBLE1M2402Ant11.02370 NVNTBLE1M2442Ant11.03066 NVNTBLE1M2480Ant11.02364 OBWNVNTBLE1M2402MHzAnt1 OBWNVNTBLE1M2442MHzAnt1 ReportNo.:BLA-EMC-202306-A4603 Page 47 of 60 BlueAsiaofTechnicalServices(Shenzhen)Co.,Ltd.Tel:+86-755-23059481Email:[email protected] OBWNVNTBLE1M2480MHzAnt1 ReportNo.:BLA-EMC-202306-A4603 Page 48 of 60 BlueAsiaofTechnicalServices(Shenzhen)Co.,Ltd.Tel:+86-755-23059481Email:[email protected] 19.4MAXIMUMPOWERSPECTRALDENSITYLEVEL ConditionModeFrequency(MHz)AntennaMaxPSD(dBm)Limit(dBm)Verdict NVNTBLE1M2402Ant1-17.418Pass NVNTBLE1M2442Ant1-20.3268Pass NVNTBLE1M2480Ant1-23.1418Pass PSDNVNTBLE1M2402MHzAnt1 PSDNVNTBLE1M2442MHzAnt1 ReportNo.:BLA-EMC-202306-A4603 Page 49 of 60 BlueAsiaofTechnicalServices(Shenzhen)Co.,Ltd.Tel:+86-755-23059481Email:[email protected] PSDNVNTBLE1M2480MHzAnt1 ReportNo.:BLA-EMC-202306-A4603 Page 50 of 60 BlueAsiaofTechnicalServices(Shenzhen)Co.,Ltd.Tel:+86-755-23059481Email:[email protected] 19.5BANDEDGE ConditionModeFrequency(MHz)AntennaMaxValue(dBc)Limit(dBc)Verdict NVNTBLE1M2402Ant1-53.14-30Pass NVNTBLE1M2480Ant1-46.05-30Pass BandEdgeNVNTBLE1M2402MHzAnt1Ref BandEdgeNVNTBLE1M2402MHzAnt1Emission ReportNo.:BLA-EMC-202306-A4603 Page 51 of 60 BlueAsiaofTechnicalServices(Shenzhen)Co.,Ltd.Tel:+86-755-23059481Email:[email protected] BandEdgeNVNTBLE1M2480MHzAnt1Ref BandEdgeNVNTBLE1M2480MHzAnt1Emission ReportNo.:BLA-EMC-202306-A4603 Page 52 of 60 BlueAsiaofTechnicalServices(Shenzhen)Co.,Ltd.Tel:+86-755-23059481Email:[email protected] ReportNo.:BLA-EMC-202306-A4603 Page 53 of 60 BlueAsiaofTechnicalServices(Shenzhen)Co.,Ltd.Tel:+86-755-23059481Email:[email protected] 19.6CONDUCTEDRFSPURIOUSEMISSION ConditionModeFrequency(MHz)AntennaMaxValue(dBc)Limit(dBc)Verdict NVNTBLE1M2402Ant1-37.75-30Pass NVNTBLE1M2442Ant1-35.16-30Pass NVNTBLE1M2480Ant1-34.86-30Pass Tx.SpuriousNVNTBLE1M2402MHzAnt1Ref Tx.SpuriousNVNTBLE1M2402MHzAnt1Emission ReportNo.:BLA-EMC-202306-A4603 Page 54 of 60 BlueAsiaofTechnicalServices(Shenzhen)Co.,Ltd.Tel:+86-755-23059481Email:[email protected] Tx.SpuriousNVNTBLE1M2442MHzAnt1Ref Tx.SpuriousNVNTBLE1M2442MHzAnt1Emission ReportNo.:BLA-EMC-202306-A4603 Page 55 of 60 BlueAsiaofTechnicalServices(Shenzhen)Co.,Ltd.Tel:+86-755-23059481Email:[email protected] Tx.SpuriousNVNTBLE1M2480MHzAnt1Ref Tx.SpuriousNVNTBLE1M2480MHzAnt1Emission ReportNo.:BLA-EMC-202306-A4603 Page 56 of 60 BlueAsiaofTechnicalServices(Shenzhen)Co.,Ltd.Tel:+86-755-23059481Email:[email protected] ReportNo.:BLA-EMC-202306-A4603 Page 57 of 60 BlueAsiaofTechnicalServices(Shenzhen)Co.,Ltd.Tel:+86-755-23059481Email:[email protected] APPENDIXA:PHOTOGRAPHSOFTESTSETUP ConductedEmissionsatACPowerLine(150kHz-30MHz) ReportNo.:BLA-EMC-202306-A4603 Page 58 of 60 BlueAsiaofTechnicalServices(Shenzhen)Co.,Ltd.Tel:+86-755-23059481Email:[email protected] RadiatedSpuriousEmissions ReportNo.:BLA-EMC-202306-A4603 Page 59 of 60 BlueAsiaofTechnicalServices(Shenzhen)Co.,Ltd.Tel:+86-755-23059481Email:[email protected] APPENDIXB:PHOTOGRAPHSOFEUT ReferencetothetestreportNo.BLA-EMC-202306-A4601 ReportNo.:BLA-EMC-202306-A4603 Page 60 of 60 BlueAsiaofTechnicalServices(Shenzhen)Co.,Ltd.Tel:+86-755-23059481Email:[email protected] ----ENDOFREPORT---- Thetestreportiseffectiveonlywithbothsignatureandspecializedstamp,Theresult(s)showninthis reportreferonlytothesample(s)tested.WithoutwrittenapprovalofBlueAsia,thisreportcan’tbe reproducedexceptinfull.

Test Report

- 1 - 嘉兴佳利电子有限公司 http://www. glead.com.cn 阿里巴巴 http://zydq.en.al iba ba.com JIA XING GLEAD ELECTRONICS CO., LTD 产 品 技 术 规 格 书 SPECIFICATION 产品型号 PART NO: GL2012H2450-D06 客户料号 CUSTOMER PART NO: 客户确认 CUSTOMER APPROVED BY: 确认日期 APPROVED DATE: 中国浙江省嘉兴市经济开发区正原路 66 号 No.66 ZhengyuanRoad, Economic Development Zone,Jiaxing,Zhejiang,China TEL:0086-573-83651818 FAX:0086-573-83651858 拟制 Prepared by: 审核 Checked by : 批准 Approved by: 送样日期 Formed On 产品版本 Document Version ( V1.5 ) - 2 - 嘉兴佳利电子有限公司 http://www. glead.com.cn 阿里巴巴 http://zydq.en.al iba ba.com JIA XING GLEAD ELECTRONICS CO., LTD 目 录 Table of contents 规格书版本更改记录 Version rejigger track record... ......... ......... ......... 3 1. 概述 Introduc tio n..................................................................4 2. 型号 P art Numb er...............................................................4 3. 外形尺寸及焊盘尺寸 Dimens io n.............................................4 4. 测试电路和匹配电路 Evaluation Board and Matc hing C ircuits.........5 5. 电气性能 Elec tric al C haracteris tics..........................................5 6. 特性曲线 C ha r a c t e r is t ic c ur ve .......................................... 5 7. 方向图 R a d ia t io n P a t t e r n ................................................... 6 8. 可靠性试验后允许误差 Post Dep endab ility To lerance ..................7 9. 可靠性试验 Depend ab ility Tes t..........................................7~8 10. 回流焊温度 Reflow So ld ering Stand ard Cond itio n........................9 11. 包装尺寸 Packaging and Dimens ions ....................................9~10 - 3 - 嘉兴佳利电子有限公司 http://www. glead.com.cn 阿里巴巴 http://zydq.en.al iba b…

Text truncated - open the document above for the full version.

Contact Information

Applicant

Ying Huang(Manager)
[email protected]0592-7885995Fax: 0592-7885995

Test Firm

BlueAsia of Technical Services (Shenzhen)Blue Zheng
[email protected]+86 755-23059481-815

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.40 GHz - 2.48 GHz605.00 µW
Confidentiality
Long Term
Grant Notes
Output power listed is conducted.

Other Applications from Xiamen Vienatone Medical Technology Co., Ltd.

Hearing aid - FCC ID 2A7JZ-2407 - Xiamen Vienatone Medical Technology Co., Ltd.
2A7JZ-2407

Hearing aid

Dec 10, 2025

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter
2A7JZ-2203

Hearing aid

Nov 26, 2025

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter
Hearing aid - FCC ID 2A7JZ-2504 - Xiamen Vienatone Medical Technology Co., Ltd.
2A7JZ-2504

Hearing aid

Nov 26, 2025

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter
Sound amplifier - FCC ID 2A7JZ-001 - Xiamen Vienatone Medical Technology Co., Ltd.
2A7JZ-001

Sound amplifier

Jul 31, 2023

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter
Sound amplifier - FCC ID 2A7JZ-CF430S - Xiamen Vienatone Medical Technology Co., Ltd.
2A7JZ-CF430S

Sound amplifier

Jul 03, 2022

Equipment Class

DXX - Part 15 Low Power Communication Device Transmitter