ZWO-AM3 User Manual Table of Contents Preface Tips Included Items 1. Product Introduction 2. Performance Parameters 3. How to Use 3.1 Introduction to the equatorial mount 3.2 Introduction to the hand controller 3.3 Mounting the equatorial mount 3.3.1 mount installation 3.3.2 Handle Controller Connection 3.3.3 Bluetooth connection 3.3.4 Pier extension (optional) installation 3.3.5 Counterweight (optional) installation 3.3.6 ASIAIR (optional) installation 3.4 Use of equatorial mount 3.4.1 How to adjust the pitch angle from the first gear to the second gear? 3.4.2 How to adjust the azimuth scale? 3.4.3 How to switch the equatorial mode to alt-azimuth mode? 3.5 How to connect the computer to control the equatorial mount? 3.6 How to use ASIAIR to control the equatorial mount? 4 Structural Dimensions 5 After sales 6 Warranty S can the QR code to watch the video Preface Thank you for purchasing the ZWO AM3 Strain Wave Gear Mount. After years of research, ZWO developed strain wave gears to meet the astrophotography needs of low periodic error, stable transmission, and high torque output. Each mount has a PE curve for performance measurement. In addition, the belt drive is adopted to achieve 300:1 reduction to achieve high-precision control. The AM3 uses updated technology, an integrated manufacturing process, and modern industrial design concepts. It is lightweight and stable while in use. It does not blindly pursue a lightweight design, but focuses, more importantly, on stability and durability during use. A Strain Wave GearGerman equatorial mount with a lightweight design, a load capacity that can meet the capacity requirements of most astrophotography setups. The AM3 equatorial mount has the capabilities of fast response, accurate tracking, convenient operation, and wide compatibility, which can meet the needs of astronomical observation and astronomical photography, and provide better assistance for astronomy enthusiasts on their star exploration journey. The purpose of this manual is to introduce the use of the equatorial mount to users in the form of text descriptions and illustrations, and to remind users of possible improper operations or dangerous situations. Please make sure to read this manual carefully before using the equatorial mount, and strictly follow the instructions in the manual carefully. Any equipment damage and personal injury caused by improper operation are the responsibility of the user. ZWO AM3 Strain Wave Gear Mount software and hardware are developed and designed with independent intellectual property rights, which are perfectly compatible with ASIAIR, and support ASCOM, INDI and other platforms. Tips This manual can guide the user to use the AM3 Strain Wave Gear Mount safely and efficiently. Before using the equatorial mount, please make sure to read the following tips carefully, and follow the instructions in this manual during actual use. 1. When using AM3, please do not directly observe or image the sun with naked eyes through telescopes or finder glasses, without using specially designed solar filters. This will cause permanent and irreversible damage to the observer's eyes, and damage to property and equipment. With solar observing and imaging, always use specially designed solar filters. 2. Please carefully select a suitable tripod according to the size and weight of the telescope and then determine if your setup needs a counterweight. Without a counterweight bar and counterweight installed on the AM3 Strain Wave Gear Mount, the center of gravity of the telescope may deviate from the tripod and cause the tripod & telescope to tip over. Please test the center of gravity of the telescope in all directions in advance to avoid this situation, causing equipment damage or personal injury. 3. After the use of the AM3, please reset the mount’s position to zero (home position), and then power down the mount. Failing to do this step will cause the home position and GOTO function to be inaccurate at the next start up, which might further cause equipment damage or personal injury. If the mount is not at home position at power down, then by the next time it is powered on, please try to return it to home position first before you do any other operation. 4.Please do stop unsupervised children from using the mount or touching the mount. This will help avoid an accidental rollover or personal injury. In addition, small parts are included with this mount which may also cause suffocation or other injuries to children. 5.Do not place the equatorial mount in a high-humidity and high-salt environment. This will cause corrosion of the mount’s components, which may cause the equatorial mount to run poorly or reduce the accuracy of the mount, and may cause short circuits and permanent damage. 6. Do not use corrosive solutions to clean the mount, so as not to corrode the surface oxide layer and damage the mount. Also exposing the mount to the sun for long periods of time may cause the appearance of the oxide layer to discolor. 7. Do not attempt to disassemble the mount. This may damage the mount, reduce the accuracy of the mount, or even cause personal injury to the user. 8. The ZWO AM3 Strain Wave Drive Mount is a precision instrument. Please handle it with care to avoid damage to the mount and reduce the accuracy. 9. The operational temperature of the ZWO AM3 Strain Wave Drive Mount is -15°C-40°C, please do not use the mount outside this temperature range. Doing so may cause the equipment to fail to operate normally and may cause equipment damage. Included Items 1. Case x1 2. AM3 mount x1 3. 2m USB2.0 cable (Type-B to Type-A) x 1 4. AM3 Periodic error report x1 5. Quick Guide Brochure x1 6. Hand Controller x1 7. 2m Hand Controller Cable x1 8. M6 Allen key x1 9. M4 Allen key x1 1.Product introduction As the second strain wave drive mount released by ZWO, the AM3 integrates lightness, precision, intelligence, and high performance into one. It meets the needs of astrophotographers and a…
Text truncated - open the document above for the full version.
SUZHOU ZWO CO., LTD. Add:Building 2, Peninsula Life Plaza, Moon bay road 6, SuZhou Ind ustrial Park, Jian, SuZhou, China Tel: +86 512 65 923102 Fax: +86 512 65923102 Email: [email protected] Date: 2023-07-25 FEDERAL COMMUNICATIONS COMMISSION Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 Dear Sir/Madam, We, SUZHOU ZWO CO., LTD., hereby authorize China Certification ICT Co., Ltd (Dongguan). to act as a laboratory for testing and test report generation for the fo llowing project(s): (Product description: ASI Mount, Model name: AM3,FCC ID: 2A7R3-ASIMOUNT ) The device su pports Bluetooth(BDR,EDR), BLE,2.4G WiFi , But for this device, only BLE 1M was active, the others were disabled by software, the end user has no capability to activate it. Sincerely, Signature: Printed Name: Yunfeng Yan Title: Manager
ATTESTATION STATEMENT SUZHOU ZWO CO., LTD. Add:Building 2, Peninsula Life Plaza, Moon bay road 6, SuZhou Industrial Park, Jian, SuZhou, China Tel: +86 512 65923102 Fax: +86 512 65923102 Email: [email protected] Date: 2023-07-25 FEDERAL COMMUNICATIONS COMMISSION Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 Ref: Attestation Statements Part 2.911(d)(5)(i), (ii) Filing FCC ID: 2A7R3-ASIMOUNT SUZHOU ZWO CO., LTD. certifies that the equipment for which authorization is sought is not “covered” equipment prohibited from receiving an equipment authorization pursuant to section 2.903 of the FCC rules. And SUZHOU ZWO CO., LTD. certifies that, as of the date of the filing of the application, the applicant is not identified on the Covered List as an entity producing “covered” equipment. Sincerely, Signed by (printed name): Yunfeng Yan Title:Manager Signature:
U.S. AGENT LETTER OF ATTESTATION Date: 2023-07-25 FEDERAL COMMUNICATIONS COMMISSION Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 Ref: Attestation Statements Part 2.911(d)(7) Filing FCC ID: 2A7R3-ASIMOUNT SUZHOU ZWO CO., LTD. certifies that, as of the date of the filing of the application, Agena AstroProducts is our designated U.S. agent for service of process for the above referenced FCC ID. SUZHOU ZWO CO., LTD. accepts to maintain an agent for no less than one year after the grantee has terminated all marketing and importation or the conclusion of any Commission-related proceeding involving the equipment. Agena AstroProducts accepts, as of the date of the filing of the application, the obligation of the designated U.S. agent for service of process for the above referenced FCC ID. Designated U.S. Agent Information: Name: Agena Astro Address: 16313 Arthur Street Cerritos, CA 90703, USA Tel.: (562) 215-4473 Email: [email protected] Signed by (printed name): Manish Panjwani Signature: Ap plicant: SUZHOU ZWO CO., LTD. Add: Building 2, Peninsula Life Plaza, Moon bay road 6, SuZhou Industrial Park, Jian, SuZhou, China FRN: 0032617060 Tel: +86 512 65923102 Email: [email protected] Signed by (printed name): Yunfeng Yan Signature:
QA-FR-170-B SUZHOU ZWO CO., LTD. Add:Building 2, Peninsula Life Plaza, Moon bay road 6, SuZhou Industrial Park, Jian, SuZhou, China Tel: +86 512 65923102 Fax: +86 512 65923102 Email: [email protected] FCC Authorization Date: 2023-07-25 FEDERAL COMMUNICATIONS COMMISSION Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 Subject: Agent Authorization To whom it may concern: We , SUZHOU ZWO CO., LTD. Hereby authorizes China Certification ICT Co., Ltd (Dongguan) to act on its behalf in all matters relating to application for Equipment authorization, including the signing of all documents relating to these matters. All acts carried out by China Certification ICT Co., Ltd (Dongguan) on our behalf shall have the same effect as our own action. We, the undersigned, hereby certify that we are not subject to a denial of federal benefits, that includes FCC benefits, pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C. 862. This authorization is valid until further written notice from the applicant. Sincerely Yours, Client’s signature Printed Name: Yunfeng Yan Title: Manager
QA -FR-171-A SUZHOU ZWO CO., LTD. Add:Building 2, Peninsula Life Plaza, Moon bay road 6, SuZhou Industrial Park, Jian, SuZhou, China Tel: +86 512 65923102 Fax: +86 512 65923102 Email: [email protected] FCC Confidential Authorization D ate: 2023-07-25 FEDERAL COMMUNICATIONS COMMISSIONS Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 S ubject: Confidentiality Request regarding application for certification of FCC ID: 2A7R3-ASIMOUNT In accordance with Sections 0.457 and 0.459 of the Commission’s Rules, (SUZHOU ZWO CO., LTD.) hereby requests long-term confidential treatment of information accompanying this application as outlined below: •Block Diagram •Schematics •Operation Description The above materials contain proprietary and confidential information not customarily released to the public. The public disclosure of these materials provides unjustified benefits to its competitors in the market. S incerely, S ignature: P rinted Name: Yunfeng Yan Title: Manager
EXHIBIT B - EUT EXTERNAL PHOTOGRAPHS EUT Ports On/Off Key
EXHIBIT C - EUT INTERNAL PHOTOGRAPHS Uncover Antenna Location Antnena Antnena Chip Chip Chip RF Chip Chip
China Certification ICT Co., Ltd (Dongguan) Report No.: CR230635583-00A Page 48 of 49 5. RF EXPOSURE EVALUATION 5.1 RF Exposure Test Exemptions for Single Source - 1-mW Test Exemption 5.1.1 Applicable Standard According to 447498 D04 Interim General RF Exposure Guidance v01, clause 2.1.2- 1-mW Test Exemption: Per §1.1307(b)(3)(i)(A), a single RF source is exempt RF device (from the requirement to show data demonstrating compliance to RF exposure limits, as previously mentioned) if the available maximum time-averaged power is no more than 1 mW, regardless of separation distance. This exemption applies to all operating configurations and exposure conditions, for the frequency range 100 kHz to 100 GHz, regardless of fixed, mobile, or portable device exposure conditions. This is a standalone exemption, and it cannot be applied in conjunction with any other test exemption. 5.1.2 Measurement Result Radio Frequency (MHz) Conducted output power including Tune- up Tolerance Antenna Gain (dBi) The Greater of Conducted Power or ERP 1-mW Test Exemption (dBm) dBm mW BLE 2402-2480 -3.5 0.23 -3.5 0.45 Compliant Result: Compliant. RF Exposure is exemption.
_____________________________________________________________________________________________________________________ *SuZhou Saixun Communication Technology Co.,Ltd. *Add:NO.629,Yunli Road,WuJiang District,SuZhou City,JiangSu Province,China *TEL : 0512-63636028 *E-Mail: [email protected] *Web:www.szsaixun.com P 1-6 Specification Customer: SuZhou Saixun Communication Technology Co.,Ltd. Product:PCB Antenna specification: I-PEX,PCB-0.81Cable,L=85mm material No.: SX-007-2208 _____________________________________________________________________________________________________________________ *SuZhou Saixun Communication Technology Co.,Ltd. *Add:NO.629,Yunli Road,WuJiang District,SuZhou City,JiangSu Province,China *TEL : 0512-63636028 *E-Mail: [email protected] *Web:www.szsaixun.com P 2-6 _____ ________________________________________________________________________________________________________________ *SuZhou Saixun Communication Technology Co.,Ltd. *Add:NO.629,Yunli Road,WuJiang District,SuZhou City,JiangSu Province,China *TEL : 0512-63636028 *E-Mail: [email protected] *Web:www.szsaixun.com P 3-6 Electrical parameters Frequency range 2.4-2.5GHz Characteristic impedance 50Ω VSWR ≦2.0 Antennadipole Polarization modehorizontal/vertical Gain 0.23dBi efficiencyreport Mechanical properties connector I-PEX I Feeder specifications RF 0.81 Feeder length 85mm antenna size 49.0*16.0 Feeder specificationsScrew locking environment specification Operating temperature -45~+85°C storage temperature -30 ~+ 65 °C ___ __________________________________________________________________________________________________________________ *SuZhou Saixun Communication Technology Co.,Ltd. *Add:NO.629,Yunli Road,WuJiang District,SuZhou City,JiangSu Province,China *TEL : 0512-63636028 *E-Mail: [email protected] *Web:www.szsaixun.com P 4-6 (return LOSS和VSWR) return LOSS VSWR Frequency ID1234567891011 Frequency (MHz)24002410242024302440245024602470248024902500 Efficiency (dBi)-6.02-6.22-6.30-6.31-6.59-7.18-7.46-7.46-7.51-8.06-8.60 Gain (dBi)0.000.150.230.22-0.16--1.32-1.37-1.25-1.21-1.69-2.47 Efficiency (%)24.9923.8923.4323.3821.9519.1517.9317.9517.7315.6513.81 _____________________________________________________________________________________________________________________ *SuZhou Saixun Communication Technology Co.,Ltd. *Add:NO.629,Yunli Road,WuJiang District,SuZhou City,JiangSu Province,China *TEL : 0512-63636028 *E-Mail: [email protected] *Web:www.szsaixun.com P 5-6 (2D&3D) 2400.0MHz Total(E1-XZ), Max= 0.00dBi 2400.0MHz Total(E2-YZ), Max= -0.03dBiTotal(H-XY), Max= -4.37dBi, CirD=14.08 2450.0MHz Total(E1-XZ), Max= -1.32dBi2450.0MHz Total(E2-YZ), Max= -1.81dBiTotal(H-XY), Max= -5.42dBi, CirD=14.73 2500.0MHz Total(E1-XZ), Max= -2.48dBi2500.0MHz Total(E2-YZ), Max= -2.47dBiTotal(H-XY), Max= -7.90dBi, CirD=18.46 _____________________________________________________________________________________________________________________ *SuZhou Saixun Communication Technology Co.,Ltd. *Add:NO.629,Yunli Road,WuJiang District,SuZhou City,JiangSu Province,China *TEL : 0512-63636028 *E-Mail: [email protected] *Web:www.szsaixun.com P 6-6 ----------------------------------------------END-------------------------------------------------
TEST REPORT Applicant: SUZHOU ZWO CO., LTD. Address: Building 2, Peninsula Life Plaza, Moon bay road 6 SuZhou Industrial Park, JiangSu, China FCC ID: 2A7R3-ASIMOUNT IC: 28392-ASIMOUNT Product Name: ASI Mount Standard(s): 47 CFR Part 15, Subpart C(15.247) RSS-247 Issue 2, February 2017 RSS-Gen, Issue 5, February 2021 Amendment 2 ANSI C63.10-2013 KDB 558074 D01 15.247 Meas Guidance v05r02 The above equipment has been tested and found compliant with the requirement of the relative standards by China Certification ICT Co., Ltd (Dongguan) Report Number: CR230635583-00A Date Of Issue: 2023/7/10 Reviewed By: Calvin Chen Title: RF Engineer Reviewed By: Sun Zhong Title: Manager Test Laboratory: China Certification ICT Co., Ltd (Dongguan) No. 113, Pingkang Road, Dalang Town, Dongguan, Guangdong, China Tel: +86-769-82016888 China Certification ICT Co., Ltd (Dongguan) Report No.: CR230635583-00A Page 2 of 49 Test Facility The Test site used by China Certification ICT Co., Ltd (Dongguan) to collect test data is located on the No. 113, Pingkang Road, Dalang Town, Dongguan, Guangdong, China. The lab has been recognized as the FCC accredited lab under the KDB 974614 D01 and is listed in the FCC Public Access Link (PAL) database, FCC Registration No. : 442868, the FCC Designation No. : CN1314. The lab has been recognized by Innovation, Science and Economic Development Canada to test to Canadian radio equipment requirements, the CAB identifier: CN0123. Declarations China Certification ICT Co., Ltd (Dongguan) is not responsible for the authenticity of any test data provided by the applicant. Data included from the applicant that may affect test results are marked with a triangle symbol “▲”. Customer model name, addresses, names, trademarks etc. are not considered data. Unless otherwise stated the results shown in this test report refer only to the sample(s) tested. This report cannot be reproduced except in full, without prior written approval of the Company. This report is valid only with a valid digital signature. The digital signature may be available only under the Adobe software above version 7.0. This report may contain data that are not covered by the accreditation scope and shall be marked with an asterisk “★”. China Certification ICT Co., Ltd (Dongguan) Report No.: CR230635583-00A Page 3 of 49 CONTENTS T EST FACILITY .......................................................................................................................................... 2 DECLARATIONS .......................................................................................................................................... 2 DOCUMENT REVISION HISTORY .......................................................................................... 5 1. GENERAL INFORMATION .................................................................................................... 6 1.1 PRODUCT DESCRIPTION FOR EQUIPMENT UNDER TEST (EUT) ....................................................... 6 1.2 DESCRIPTION OF TEST CONFIGURATION ........................................................................................... 8 1.2.2 Support Equipment List and Details .............................................................................................................. 8 1.2.3 Support Cable List and Details ...................................................................................................................... 8 1.2.4 Block Diagram of Test Setup ......................................................................................................................... 9 1.3 MEASUREMENT UNCERTAINTY ........................................................................................................ 10 2. SUMMARY OF TEST RESULTS .......................................................................................... 11 3. REQUIREMENTS AND TEST PROCEDURES .................................................................. 12 3.1 AC LINE CONDUCTED EMISSIONS .................................................................................................... 12 3.1.1 Applicable Standard ..................................................................................................................................... 12 3.1.2 EUT Setup.................................................................................................................................................... 14 3.1.3 EMI Test Receiver Setup ............................................................................................................................. 14 3.1.4 Test Procedure ............................................................................................................................................. 15 3.1.5 Corrected Amplitude & Margin Calculation ................................................................................................ 15 3.2 RADIATION SPURIOUS EMISSIONS .................................................................................................... 16 3.2.1 Applicable Standard ..................................................................................................................................... 16 3.2.2 EUT Setup.................................................................................................................................................... 16 3.2.3 EMI Test Receiver & Spectrum Analyzer Setup ......................................................................................... 17 3.2.4 Test Procedure ............................................................................................................................................. 17 3.2.5 Corrected Amplitude & Margin Calculation ................................................................................................ 18 3.3 6 DB EMISSION BANDWIDTH: ............................................................................................................ 19 3.3.1 Applicable Standard .....…
Text truncated - open the document above for the full version.
EXHIBIT D - TEST SETUP PHOTOGRAPHS Conducted Emissions Front View Conducted Emissions Side View Radiated Emission Below 1GHz View Radiated Emission Above 1GHz View
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 2.40 GHz - 2.48 GHz | 400.00 µW |
Astrophotography Wireless Controller
Equipment Class
DTS - Digital Transmission SystemASIMOUNT
Equipment Class
DTS - Digital Transmission System
ASI Mount
Equipment Class
DTS - Digital Transmission System