SE2SE2 26 [email protected]
Rev 1/26/2023 Urocomm International Limited Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 USA Date: 2026-03-05 Ref: Attestation Statements Part 2.911(d)(7) Filing FCC ID: 2A7R8-SE2 Applicant FRN: 0032606196 [Urocomm International Limited] (“the applicant”) certifies that, as of the date of the filing of the application, FCC US Agent, LLC is our designated U.S. agent for service of process for the above referenced FCC ID. [Urocomm International Limited] accepts to maintain an agent for no less than one year after the grantee has terminated all marketing and importation or the conclusion of any Commission-related proceeding involving the equipment. FCC US Agent, LLC accepts, as of the date of the filing of the application, the obligation of the designated U.S. agent for service of process for the above referenced FCC ID. Designated U.S. Agent Information: Company Name: FCC US Agent, LLC FRN: 0033402884 Address: 3722 Illinois Avenue, Saint Charles, IL, 60174, USA Contact Person: Tim Payne Phone: 708-571-3148 Email: [email protected] Sincerely, Urocomm International Limited FCC US Agent, LLC Weihua NIU Tim Payne
FCC ID:2A7R8-SE2 Label location
AUDIX Technology (Shenzhen) Co., Ltd. Audix Technology (Shenzhen) Co., ltd.. Report No. ACS-SF26006 Page 1 of 124 SAR TEST REPORT for Urocomm International Limited Macaroon LTE Mobile Router Model No.: SE2 FCC ID: 2A7R8-SE2 The MAX Report SAR(1g) Body SAR 1.377W/Kg Test distance: 0mm Prepared for : Urocomm International Limited SUITE 1601,16TH FLOOR CHINACHEM HOLLYWOOD CENTRE 1-13 HOLLYWOOD ROAD CENTRAL HK Prepared By : Audix Technology (Shenzhen) Co., Ltd. No. 6, Kefeng Road, Science &Technology Park, Nanshan District, Shenzhen, Guangdong, China Tel: (0755) 26639496 Fax: (0755) 26632877 Report No. : ACS-SF26006 Date of Test : Jan.28~Mar.09, 2026 Date of Report : Mar.11, 2026 AUDIX Technology (Shenzhen) Co., Ltd. Audix Technology (Shenzhen) Co., ltd.. Report No. ACS-SF26006 Page 2 of 124 TABLE OF CONTENTS Description Page TEST REPORT VERIFICATION..............................................................................3 1. GENERAL INFORMATION ...................................................................................................... 4 1.1. Description of Equipment Under Test ............................................................................................... 4 2. GENERAL DESCRIPTION ........................................................................................................ 6 2.1. Product Description For EUT ............................................................................................................ 6 2.2. Applied Standards ............................................................................................................................. 6 2.3. Device Description and SAR Limits ................................................................................................. 6 2.4. Test Conditions .................................................................................................................................. 6 2.5. Exposure Positions Consideration ..................................................................................................... 7 2.6. Standalone SAR Test Exclusion Considerations ............................................................................... 8 2.7. EUT Configuration and operation conditions for test. .................................................................... 10 2.8. Test Equipments .............................................................................................................................. 10 2.9. Laboratory Environment ................................................................................................................. 12 2.10. Measurement Uncertainty ............................................................................................................... 12 3. MEASURE PROCEDURES ...................................................................................................... 15 3.1. General description of test procedures ............................................................................................ 15 4. SAR MEASUREMENTS SYSTEM .......................................................................................... 16 4.1. SAR Measurement Set-up ............................................................................................................... 16 4.2. ELI Phantom .................................................................................................................................... 17 4.3. Device Holder for SAM Twin Phantom .......................................................................................... 18 4.4. DASY5 E-field Probe System ......................................................................................................... 19 4.5. E-field Probe Calibration ................................................................................................................. 20 4.6. Scanning procedure ......................................................................................................................... 21 5. DATA STORAGE AND EVALUATION ................................................................................. 23 5.1. Data Storage .................................................................................................................................... 23 5.2. Data Evaluation by SEMCAD ......................................................................................................... 23 6. SYSTEM CHECK ...................................................................................................................... 25 7. TEST RESULTS ......................................................................................................................... 27 7.1. Output power ................................................................................................................................... 27 7.2. System Check for Head Tissue simulating liquid ......................................................................... 104 7.3. Dielectric Performance for Tissue simulating liquid ..................................................................... 112 7.4. Test Results ................................................................................................................................... 114 APPENDIX A (Graph Result- UMTS & E-UTRA) APPENDIX B (Graph Result- WIFI 2.4GHz) APPENDIX C (Calibration Certificate) APPENDIX D (Test Photos) APPENDIX E (EUT Photos) AUDIX Technology (Shenzhen) Co., Ltd. Audix Technology (Shenzhen) Co., ltd.. Report No. ACS-SF26006 Page 3 of 124 SAR TEST REPORT Applicant : Urocomm International Limited Manufacturer : Urocomm International Limited Product : Macaroon LTE Mobile Router Model No. : SE2 FCC ID : 2A7R8-SE2 Test Voltage : DC 5V Measurement Standard Used: ·FCC 47 CFR Part 2 (2.1093) · IEEE C95.1-1999 ·EN IEC-IEEE 62209-1528: 2021 · FCC OET Bulletin 65 Supplement C (Edition 01-01) · FCC KDB 447498 D04 v01 · FCC KDB 865664 D01/D02 · FCC KDB 248227 D01 v02r02 The device…
Text truncated - open the document above for the full version.
Saiwei-Sai to far, Wei to eternity! Customer name: Qin Zhou Project name: QM62(SE light) Report time: 20260331 Saiwei-to go far, Wei for eternity! Saiwei-Sai to far, Wei to eternity! type template Antenna Overview main antenna frequency rangeAntenn a status Antenna type Design area Match changes 2G FPC PIFA 3G 4G1/2/3/4/5/7/8/12/ 13/18/19/20/25/26 /28/34/38/39/40/ 41/66 Other antennas BT/WIFI2.4G PIFA GPS diversi ty PIFA Prototyp e status Environmental Treatment editiondateContent Overview V120260331data report Saiwei-Sai to far, Wei to eternity! Saiwei-Sai to far, Wei to eternity! StandardBand Gain(dbi) LTEB1 0.52 LTEB2 1.11 LTEB3 -0.37 LTEB4 -0.24 LTEB5 -1.31 LTEB7 0.88 LTEB8 -0.45 LTEB12 -2.76 LTEB13 -2.51 LTEB18 -1.31 LTEB19 -1.31 Saiwei - Sai is far away, and Wei is eternal! StandardBand Gain(dbi) LTEB20 -1.31 LTEB25 -0.11 LTEB26 -1.31 LTEB28 -2.76 LTEB34 -0.35 LTEB38 1.12 LTEB39 0.39 LTEB40 0.44 LTEB41 1.11 LTEB66 0.53 BT/WIFI2.4G -0.25 700M 800M 900M 1700M 1800M 1900M 2100M 2300M 2600M WIFI/BT Saiwei-Sai to far, Wei to eternity! Please carefully verify whether the matching circuit mentioned in the report has been modified and whether the environmental processing has been imported, which will directly affect the antenna performance. Note: The parameters in this report are solely for our companys prototype debugging and do not reflect the final production status of your companys project. If your company has a prototype with the latest trial production or updated status (such as material replacement, software update, or environmental processing change), please submit it to us for verification as soon as possible to confirm whether the antenna performance is affected. If your company needs to send the antenna to a third party for retest or to the customer for test, please submit the machine to be tested to our company for test confirmation, because the consistency of the motherboard, the consistency of the assembly, and the difference in the antenna assembly may lead to the deviation of the antenna parameters. Saiwei-Sai to far, Wei to eternity! THANKS! Saiwei-Sai to far, Wei to eternity! Antenna Manufacturer Address Room 401, Building 211, Tairan Industry & Trade Park, Chegongmiao, Futian District, Shenzhen City
AUDIX Technology (Shenzhen) Co., Ltd. FCC ID: 2A7R8-SE2 Audix Technology (Shenzhen) Co., Ltd. Report No. ACS-F26037 Page 1 of 219 FCC PART 15C TEST REPORT FOR CERTIFICATION On Behalf of Urocomm International Limited Macaroon LTE Mobile Router SE2 FCC ID: 2A7R8-SE2 Brand: macaroon Prepared for : Urocomm International Limited SUITE 1601,16TH FLOOR CHINACHEM HOLLYWOOD CENTRE 1-13 HOLLYWOOD ROAD CENTRAL HK Prepared By : Audix Technology (Shenzhen) Co., Ltd. No. 6, Kefeng Road, Science & Technology Park, Nanshan District , Shenzhen, Guangdong, China Tel: (0755) 26639496 Report Number : ACS-F26037 Date of Test : Jan.27~Feb.05, 2026 Date of Report : Mar.11, 2026 AUDIX Technology (Shenzhen) Co., Ltd. FCC ID: 2A7R8-SE2 Audix Technology (Shenzhen) Co., Ltd. Report No. ACS-F26037 Page 2 of 219 TABLE OF CONTENTS Description Page 1. SUMMARY OF STANDARDS AND RESULTS ............................................................. 5 1.1. Description of Standards and Results ..................................................................................... 5 2. GENERAL INFORMATION ............................................................................................. 6 2.1. Description of Equipment Under Test .................................................................................... 6 2.2. Feature of Equipment Under Test ........................................................................................... 7 2.3. Tested Supporting System Details .......................................................................................... 8 2.4. Block diagram of connection between the EUT and simulators ............................................. 8 2.5. Test Equipments ...................................................................................................................... 9 2.6. Test Information .................................................................................................................... 10 2.7. Test Facility ........................................................................................................................... 11 2.8. Measurement Uncertainty (95% confidence levels, k=2) ..................................................... 11 3. POWER LINE CONDUCTED EMISSION TEST ........................................................ 12 3.1. Block Diagram of Test Setup ................................................................................................ 12 3.2. Power Line Conducted Emission Test Limits ....................................................................... 12 3.3. Configuration of EUT on Test .............................................................................................. 12 3.4. Operating Condition of EUT ................................................................................................. 13 3.5. Test Procedure ....................................................................................................................... 13 3.6. Power Line Conducted Emission Test Results ..................................................................... 13 4. RADIATED EMISSION TEST ........................................................................................ 16 4.1. Block Diagram of Test Setup ................................................................................................ 16 4.2. Radiated Emission Limits ..................................................................................................... 17 4.3. EUT Configuration on Test ................................................................................................... 17 4.4. Operating Condition of EUT ................................................................................................. 18 4.5. Test Procedure ....................................................................................................................... 18 4.6. Radiated Emission Test Results ............................................................................................ 18 5. CONDUCTED SPURIOUS EMISSIONS ..................................................................... 132 5.1. Limit .................................................................................................................................... 132 5.2. Test Procedure ..................................................................................................................... 132 5.3. Test result ............................................................................................................................ 132 6. BAND EDGE COMPLIANCE TEST ............................................................................ 151 6.1. Limit .................................................................................................................................... 151 6.2. Test Procedure ..................................................................................................................... 151 6.3. Test Results ......................................................................................................................... 151 7. 6dB & 99% Bandwidth Test ........................................................................................... 200 7.1. Limit .................................................................................................................................... 200 7.2. Test Procedure ..................................................................................................................... 200 7.3. Test Results ......................................................................................................................... 201 8. OUTPUT POWER TEST ............................................................................................... 209 8.1. Limit (FCC Part 15C 15.247 b(3)) ...................................................................................... 209 8.2. Test Procedure ...................................................…
Text truncated - open the document above for the full version.
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 2.41 GHz - 2.46 GHz | 70.00 mW |

Starway Global USB WiFi Stick
Equipment Class
DTS - Digital Transmission System