FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Shenzhen Qianyan Technology LTD/
  3. 2A7VD-H5042

2A7VD-H5042Smart Gateway 1s

Shenzhen Qianyan Technology LTD

Application Details

Equipment Class
DTS - Digital Transmission System
Date of Grant
Apr 01, 2024
Application Purpose
Original Equipment
Date of Application
Apr 01, 2024
Equipment Note
Smart Gateway 1s
Frequency Range
2412.00000000 - 2462.00000000
Company
Shenzhen Qianyan Technology LTD
Country
China

Documents & Files

Select a file to view

Attestation Statements

↗
↗

Cover Letter(s)

↗
↗
↗
↗

ID Label/Location Info

↗

RF Exposure Info

↗

Test Report

↗
↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Attestation Statements

Shenzhen Qianyan Technology LTD Address: No.3301, Block C, Section 1, Chuangzhi Yuncheng Building, Liuxian Avenue, Xili Community, Xili Street, Nanshan District, Shenzhen, China Email: [email protected] Tel: +86-13632599550 Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 USA Date: 2024-03-11 FCC ID: 2A7VD-H5042 Ref. #1: Attestation Statements Part 2.911(d)(5)(i) Filing Shenzhen Qianyan Technology LTD certifies that the equipment for which authorization is sought is not “covered” equipment prohibited from receiving an equipment authorization pursuant to section 2.903 of the FCC rules. Ref. #2: Attestation Statements Part 2.911(d)(5)(ii) Filing Shenzhen Qianyan Technology LTD certifies that, as of the date of the filing of the application, the applicant is notidentified on the Covered List (as a specifically named entity or any of its subsidiaries or affiliates)as an entity producing “covered” equipment. Applicant: Shenzhen Qianyan Technology LTD Address: No.3301, Block C, Section 1, Chuangzhi Yuncheng Building, Liuxian Avenue, Xili Community, Xili Street, Nanshan District, Shenzhen, China Contact Person: Xiaopeng Pan, Certification Manager Tel.: +86-13632599550 Email: [email protected] Sincerely, Signature:

Attestation Statements

U.S. AGENT LETTER OF ATTESTATION Date: 2024-03-11 FEDERAL COMMUNICATIONS COMMISSION Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 Ref: Attestation Statements CFR 47 §2.911(d)(7) Filing FCC ID: 2A7VD-H5042 Shenzhen Qianyan Technology LTD certifies that, as of the date of the filing of the application, GOVEE MOMENTS(US) TRADING LIMITED is our designated U.S. agent for service of process for the above referenced FCC ID. Shenzhen Qianyan Technology LTD accepts to maintain an agent for no less than one year after the grantee has terminated all marketing and importation or the conclusion of any Commission-related proceeding involving the equipment. GOVEE MOMENTS(US) TRADING LIMITED accepts, as of the date of the filing of the application, the obligation of the designated U.S. agent for service of process for the above referenced FCC ID. Designated U.S. Agent Information: Name: GOVEE MOMENTS(US) TRADING LIMITED Address: 2501 Chatham Rd Suite R Springfield IL 62704 FRN: 0033426016 Tel.: 001 (206) 604-2935 Email: [email protected] Signed by (printed name): Jenny You Signature: Applicant: Shenzhen Qianyan Technology LTD Address: No.3301, Block C, Section 1, Chuangzhi Yuncheng Building, Liuxian Avenue, Xili Community, Xili Street, Nanshan District, Shenzhen, China FRN: 0032478174 Tel: +86-13632599550 Email: [email protected] Signed by (printed name): Xiaopeng Pan Signature:

Cover Letter(s)

Antenna test report Test Laboratory Dongguan Yijia Electronic Co., LTD Address No. 59 Muyu Road, Shatou Community, Chang 'an Town, Dongguan City, Guangdong Province Contact: Mr. Gan 13823198410 Model H5042 Manufacturer Shenzhen Qianyan Technology LTD Address: No.3301, Block C, Section 1, Chuangzhi Yuncheng Building, Liuxian Avenue, Xili Community, Xili Street, Nanshan District, Shenzhen, China 1. Test procedures Name Parameter Method Standard No. Mobile communication antenna VSWR Generic specificaiton for antennas used in the mobile communications GB/T 9410-2008 Antenna Gain Radiation pattern Antenna Radiation efficiency IEEE Standard Test Procedures for Antennas ANSI/IEEE Std 149-1979 2. Test Equipment Equipment Model No. Serial No. Manufacture Calibration Date Next calibration Date 24 probe Microwave chamber MPS2450 Multi- probeOTAme asurement systems 5*5*5 YJ-PB-F01 XH-IOE 2023.09.01 2024.09.01 Network Analyzer ZVB8 YJ-RD- 15 ROHDE&SCH WARS 2023.08.25 2024.08.25 Wideb and radio Communication tester CMW500 YJ-RD- 16 ROHDE&SCH WARS 2023.08.25 2024.08.25 3. DUT Setup Photo 4. 2.4G Antenna Physical Size 5. 2.4G Antenna Type & Gain Type: PCB Antenna Frequency / MHz Gain/ dBi 2400 2.48 2410 2.7 2420 2.71 2430 2.84 2440 2.99 2450 3.38 2460 2.96 2470 3.51 2480 3.53 2490 3.85 2500 3.4 6. . 2.4G An Tester by: ntenna Pat Wu xianmin ttern Pictu ng ure 240 2 2 0MHz 450MHz 500MHz

Cover Letter(s)

Shenzhen Qianyan Technology LTD Address: No.3301, Block C, Section 1, Chuangzhi Yuncheng Building, Liuxian Avenue, Xili Community, Xili Street, Nanshan District, Shenzhen, China Email: [email protected] Tel: +86-13632599550 Date:2024-03-11 Product Model Number: H5042 FCC ID:2A7VD-H5042 To whom it may concern, Re: Product Certification Representative Authorization Letter We authorize China Certification ICT Co., Ltd (Dongguan)(address: No. 113, Pingkang Road, Dalang Town, Dongguan, Guangdong, China) to act on our behalf on all matters concerning the above named equipment. This shall include the following:  Testing  Approval applications and procedures We declare that China Certification ICT Co., Ltd (Dongguan) is allowed to forward all information related to the approval project to the applied certification body and to the notification entities and to discuss any issues concerning the approval application. Any and all acts carried out by China Certification ICT Co., Ltd (Dongguan) on our behalf shall have the same effect as acts of our own. By: Contact Listed on FCC Wesbite Xiaopeng Pan Title: Certification Manager Email: [email protected] Telephone: +86-13632599550 On behalf of: Shenzhen Qianyan Technology LTD

Cover Letter(s)

Shenzhen Qianyan Technology LTD Address: No.3301, Block C, Section 1, Chuangzhi Yuncheng Building, Liuxian Avenue, Xili Community, Xili Street, Nanshan District, Shenzhen, China Email: [email protected] Tel: +86-13632599550 Office of Engineering Technology Federal Communications Commission 7435 Oakland Mills Road Columbia, MD 21046 USA Date: 2024-03-11 Subject; Request for Confidentiality FCC ID: 2A7VD-H5042 To Whom It May Concern, Pursuant to the provisions of the Commission’s rules Title 47 Sections §0.457 and §0.459, we are requesting the Commission to withhold the following attachment(s) as confidential documents from public disclosure indefinitely. These documents contain detailed system and equipment descriptions and are considered as proprietary information in operation of the equipment. The public disclosure of these documents might be harmful to our company and would give competitors an unfair advantage in the market. Schematic Diagram Block Diagram Parts List Operational Description Tune-up Procedure Software Security Requirements for UNII devices In additional to above mentioned documents, in order to comply with the marketing regulations in Title 47 CFR §2.803 and the importation rules in Title 47 CFR §2.1204, while ensuring that business sensitive information remains confidential until the actual marketing of newly authorized devices, we request Short Term Confidentiality of the following attachment(s); External Photos Test Setup Photos Internal Photos User Manual For 45 days, pursuant to Public Notice DA 04-1705. OR For 180 days pursuant to KDB 726920 D01. It is our understanding that all measurement test reports, FCC ID label format and correspondence during the certification review process cannot be granted as confidential documents and this information will be available for public review once the grant of equipment authorization is issued. Sincerely, Signature: Name:Xiaopeng Pan Title:Certification Manager

Cover Letter(s)

Shenzhen Qianyan Technology LTD Address: No.3301, Block C, Section 1, Chuangzhi Yuncheng Building, Liuxian Avenue, Xili Community, Xili Street, Nanshan District, Shenzhen, China Email: [email protected] Tel: +86-13632599550 Date: 2024-03-11 FEDERAL COMMUNICATIONS COMMISSIONS Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 Attestation letter Dear Sir or Madam, Our product Smart Gateway 1s, model: H5042, FCC ID: 2A7VD-H5042, for marketing purpose, this product only supports SRD( 433.88 MHz), BLE 1M, 2.4G Wi-Fi(2412-2462MHz, 802.11b/g/n20 modes).The other functions, bands and modes was disabled to use by manufacturer in the software, the end user has no capability to activate it. Sincerely, Signature: Name:Xiaopeng Pan Title:Certification Manager

RF Exposure Info

RF EXPOSURE EVALUATION Applicant: Shenzhen Qianyan Technology LTD Address: No.3301, Block C, Section 1, Chuangzhi Yuncheng Building, Liuxian Avenue, Xili Community, Xili Street, Nanshan District, Shenzhen, China FCC ID: 2A7VD-H5042 Product Name: Smart Gateway 1s Standard(s): 47 CFR §1.1307, 47 CFR §2.1091 447498 D04 Interim General RF Exposure Guidance v01 The above device has been tested and found compliant with the requirement of the relative standards by China Certification ICT Co., Ltd (Dongguan) Report Number: CR231166640-00D Date Of Issue: 2024/3/14 Reviewed By: Calvin Chen Title: RF Engineer Approved By: Sun Zhong Title: Manager Test Laboratory: China Certification ICT Co., Ltd (Dongguan) No. 113, Pingkang Road, Dalang Town, Dongguan, Guangdong, China Tel: +86-769-82016888 China Certification ICT Co., Ltd (Dongguan) Report No.: CR231166640-00D Page 2 of 7 Test Facility The Test site used by China Certification ICT Co., Ltd (Dongguan) to collect test data is located on the No. 113, Pingkang Road, Dalang Town, Dongguan, Guangdong, China. The lab has been recognized as the FCC accredited lab under the KDB 974614 D01 and is listed in the FCC Public Access Link (PAL) database, FCC Registration No. : 442868, the FCC Designation No. : CN1314. Declarations China Certification ICT Co., Ltd (Dongguan) is not responsible for the authenticity of any test data provided by the applicant. Data included from the applicant that may affect test results are marked with a triangle symbol “▲”. Customer model name, addresses, names, trademarks etc. are not considered data. Unless otherwise stated the results shown in this test report refer only to the sample(s) tested. This report cannot be reproduced except in full, without prior written approval of the Company. This report is valid only with a valid digital signature. The digital signature may be available only under the Adobe software above version 7.0. This report may contain data that are not covered by the accreditation scope and shall be marked with an asterisk “★”. China Certification ICT Co., Ltd (Dongguan) Report No.: CR231166640-00D Page 3 of 7 CONTENTS DOCUMENT REVISION HISTORY .......................................................................................... 4 1. RF EXPOSURE EVALUATION .............................................................................................. 5 1.1 APPLICABLE STANDARD ...................................................................................................................... 5 1.2 MEASUREMENT RESULT ..................................................................................................................... 7 China Certification ICT Co., Ltd (Dongguan) Report No.: CR231166640-00D Page 4 of 7 DOCUMENT REVISION HISTORY Revision Number Report Number Description of Revision Date of Revision 1.0 CR231166640-00D Original Report 2024/3/14 China Certification ICT Co., Ltd (Dongguan) Report No.: CR231166640-00D Page 5 of 7 1. RF EXPOSURE EVALUATION 1.1 Applicable Standard According to §1.1307(b)(3)(ii)(B) Simultaneous Transmission with both SAR-based and MPE-Based Test Exemptions This case is described in detail in § 1.1307(b)(3)(ii)(B) and covers the situations where both SAR- based and MPE-based exemption may be considered for test exemption in fixed, mobile, or portable device exposure conditions. For these cases, a device with multiple RF sources transmitting simultaneously will be considered an RF exempt device if the condition of Formula (1) is satisfied. Table 1 to § 1.1307(b)(3)(i)(C) - Single RF Sources Subject to Routine Environmental Evaluation RF Source frequency (MHz) Threshold ERP (watts) 0.3-1.34 1,920 R 2 . 1.34-30 3,450 R 2 /f 2 . 30-300 3.83 R 2 . 300-1,500 0.0128 R 2 f. 1,500-100,000 19.2R 2 . China Certification ICT Co., Ltd (Dongguan) Report No.: CR231166640-00D Page 6 of 7 China Certification ICT Co., Ltd (Dongguan) Report No.: CR231166640-00D Page 7 of 7 1.2 Measurement Result Radio Frequency (MHz) λ/2Π (mm) Distance (mm) Exemption ERP (mW) Maximum Conducted Power including Tune-up Tolerance (dBm) Antenna Gain (dBi) ERP dBm mW Wi-Fi 2412-2462 19.80 200 768 18 3.51 19.36 86.30 BLE 2402-2480 19.88 200 768 1 3.53 2.38 1.73 SRD 433.88 110.05 200 222 / -3.06 -0.98 0.80 Note: 1. The Maximum Conducted Power including Tune-up Tolerance was declared by manufacturer. 2. For SRD, This device maximum E-Field level is 96.37 dBμV/m at 3m, so the EIRP power is 1.17 dBm. 3. EIRP (dBm)=Field Strength of Fundamental(dBuV/m)-95.2 4. ERP (dBm)= EIRP (dBm)-2.15 The Wi-Fi or BLE and SRD can transmit simultaneously. =ERP Wi-Fi / ERP th + P SRD / ERP th = 86.30/768 + 0.80/222 =0.116 < 1.0 Result: The device meet FCC MPE at 20 cm distance. ===== END OF REPORT =====

Test Report

TEST REPORT Applicant: Shenzhen Qianyan Technology LTD Address: No.3301, Block C, Section 1, Chuangzhi Yuncheng Building, Liuxian Avenue, Xili Community, Xili Street, Nanshan District, Shenzhen, China FCC ID: 2A7VD-H5042 Product Name: Smart Gateway 1s Standard(s): 47 CFR Part 15, Subpart C(15.247) ANSI C63.10-2013 KDB 558074 D01 15.247 Meas Guidance v05r02 The above device has been tested and found compliant with the requirement of the relative standards by China Certification ICT Co., Ltd (Dongguan) Report Number: CR231166640-00B Date Of Issue: 2024/3/11 Reviewed By: Calvin Chen Title: RF Engineer Approved By: Sun Zhong Title: Manager Test Laboratory: China Certification ICT Co., Ltd (Dongguan) No. 113, Pingkang Road, Dalang Town, Dongguan, Guangdong, China Tel: +86-769-82016888 China Certification ICT Co., Ltd (Dongguan) Report No.: CR231166640-00B Page 2 of 63 Test Facility The Test site used by China Certification ICT Co., Ltd (Dongguan) to collect test data is located on the No. 113, Pingkang Road, Dalang Town, Dongguan, Guangdong, China. The lab has been recognized as the FCC accredited lab under the KDB 974614 D01 and is listed in the FCC Public Access Link (PAL) database, FCC Registration No. : 442868, the FCC Designation No. : CN1314. Declarations China Certification ICT Co., Ltd (Dongguan) is not responsible for the authenticity of any test data provided by the applicant. Data included from the applicant that may affect test results are marked with a triangle symbol “▲”. Customer model name, addresses, names, trademarks etc. are not considered data. Unless otherwise stated the results shown in this test report refer only to the sample(s) tested. This report cannot be reproduced except in full, without prior written approval of the Company. This report is valid only with a valid digital signature. The digital signature may be available only under the Adobe software above version 7.0. This report may contain data that are not covered by the accreditation scope and shall be marked with an asterisk “★”. China Certification ICT Co., Ltd (Dongguan) Report No.: CR231166640-00B Page 3 of 63 CONTENTS DOCUMENT REVISION HISTORY .......................................................................................... 5 1. GENERAL INFORMATION .................................................................................................... 6 1.1 PRODUCT DESCRIPTION FOR EQUIPMENT UNDER TEST (EUT) ....................................................... 6 1.2 DESCRIPTION OF TEST CONFIGURATION ........................................................................................... 7 1.2.1 EUT Operation Condition: ............................................................................................................................. 7 1.2.2 Support Equipment List and Details .............................................................................................................. 7 1.2.3 Support Cable List and Details ...................................................................................................................... 7 1.2.4 Block Diagram of Test Setup ......................................................................................................................... 8 1.3 MEASUREMENT UNCERTAINTY .......................................................................................................... 9 2. SUMMARY OF TEST RESULTS .......................................................................................... 10 3. REQUIREMENTS AND TEST PROCEDURES .................................................................. 11 3.1 AC LINE CONDUCTED EMISSIONS .................................................................................................... 11 3.1.1 Applicable Standard ..................................................................................................................................... 11 3.1.2 EUT Setup.................................................................................................................................................... 12 3.1.3 EMI Test Receiver Setup ............................................................................................................................. 12 3.1.4 Test Procedure ............................................................................................................................................. 13 3.1.5 Corrected Amplitude & Margin Calculation ................................................................................................ 13 3.2 RADIATION SPURIOUS EMISSIONS .................................................................................................... 14 3.2.1 Applicable Standard ..................................................................................................................................... 14 3.2.2 EUT Setup.................................................................................................................................................... 14 3.2.3 EMI Test Receiver & Spectrum Analyzer Setup ......................................................................................... 15 3.2.4 Test Procedure ............................................................................................................................................. 16 3.2.5 Corrected Amplitude & Margin Calculation ................................................................................................ 16 3.3 MINIMUM 6 DB EMISSION BANDWIDTH ........................................................................................... 17 3.3.1 Applicable Standard ..................................................................................................................................... 17 3.3.2 EUT Setup.................................................................................................................................................... 17 3.3.3 Test Procedure ...................................…

Text truncated - open the document above for the full version.

Test Report

TEST REPORT Applicant: Shenzhen Qianyan Technology LTD Address: No.3301, Block C, Section 1, Chuangzhi Yuncheng Building, Liuxian Avenue, Xili Community, Xili Street, Nanshan District, Shenzhen, China FCC ID: 2A7VD-H5042 Product Name: Smart Gateway 1s Standard(s): 47 CFR Part 15, Subpart C(15.247) ANSI C63.10-2013 KDB 558074 D01 15.247 Meas Guidance v05r02 The above device has been tested and found compliant with the requirement of the relative standards by China Certification ICT Co., Ltd (Dongguan) Report Number: CR231166640-00C Date Of Issue: 2024/3/11 Reviewed By: Calvin Chen Title: RF Engineer Approved By: Sun Zhong Title: Manager Test Laboratory: China Certification ICT Co., Ltd (Dongguan) No. 113, Pingkang Road, Dalang Town, Dongguan, Guangdong, China Tel: +86-769-82016888 China Certification ICT Co., Ltd (Dongguan) Report No.: CR231166640-00C Page 2 of 51 Test Facility The Test site used by China Certification ICT Co., Ltd (Dongguan) to collect test data is located on the No. 113, Pingkang Road, Dalang Town, Dongguan, Guangdong, China. The lab has been recognized as the FCC accredited lab under the KDB 974614 D01 and is listed in the FCC Public Access Link (PAL) database, FCC Registration No. : 442868, the FCC Designation No. : CN1314. Declarations China Certification ICT Co., Ltd (Dongguan) is not responsible for the authenticity of any test data provided by the applicant. Data included from the applicant that may affect test results are marked with a triangle symbol “▲”. Customer model name, addresses, names, trademarks etc. are not considered data. Unless otherwise stated the results shown in this test report refer only to the sample(s) tested. This report cannot be reproduced except in full, without prior written approval of the Company. This report is valid only with a valid digital signature. The digital signature may be available only under the Adobe software above version 7.0. This report may contain data that are not covered by the accreditation scope and shall be marked with an asterisk “★”. China Certification ICT Co., Ltd (Dongguan) Report No.: CR231166640-00C Page 3 of 51 CONTENTS DOCUMENT REVISION HISTORY .......................................................................................... 5 1. GENERAL INFORMATION .................................................................................................... 6 1.1 PRODUCT DESCRIPTION FOR EQUIPMENT UNDER TEST (EUT) ....................................................... 6 1.2 DESCRIPTION OF TEST CONFIGURATION ........................................................................................... 7 1.2.1 EUT Operation Condition: ............................................................................................................................. 7 1.2.2 Support Equipment List and Details .............................................................................................................. 7 1.2.3 Support Cable List and Details ...................................................................................................................... 7 1.2.4 Block Diagram of Test Setup ......................................................................................................................... 8 1.3 MEASUREMENT UNCERTAINTY .......................................................................................................... 9 2. SUMMARY OF TEST RESULTS .......................................................................................... 10 3. REQUIREMENTS AND TEST PROCEDURES .................................................................. 11 3.1 AC LINE CONDUCTED EMISSIONS .................................................................................................... 11 3.1.1 Applicable Standard ..................................................................................................................................... 11 3.1.2 EUT Setup.................................................................................................................................................... 12 3.1.3 EMI Test Receiver Setup ............................................................................................................................. 12 3.1.4 Test Procedure ............................................................................................................................................. 13 3.1.5 Corrected Amplitude & Margin Calculation ................................................................................................ 13 3.2 RADIATION SPURIOUS EMISSIONS .................................................................................................... 14 3.2.1 Applicable Standard ..................................................................................................................................... 14 3.2.2 EUT Setup.................................................................................................................................................... 14 3.2.3 EMI Test Receiver & Spectrum Analyzer Setup ......................................................................................... 15 3.2.4 Test Procedure ............................................................................................................................................. 16 3.2.5 Corrected Amplitude & Margin Calculation ................................................................................................ 16 3.3 MINIMUM 6 DB BANDWIDTH ............................................................................................................. 17 3.3.1 Applicable Standard ..................................................................................................................................... 17 3.3.2 EUT Setup.................................................................................................................................................... 17 3.3.3 Test Procedure ..........................…

Text truncated - open the document above for the full version.

Contact Information

Applicant

Xiaopeng Pan
[email protected]+86-13632599550Fax: 0755-23739351

Technical Contact

Shenzhen Qianyan Technology LTD
[email protected]

China

Test Firm

CHINA CERTIFICATION ICT CO., LTD (DONGGUAN)Tanie Ou
[email protected]0086 0769 86858888

Technical Specifications

#Rule PartsFrequency RangePower Output
215C2.41 GHz - 2.46 GHz51.00 mW
Confidentiality
Long Term
Grant Notes
Power listed is the maximum conducted output power. The antennas used with this transmitter must be installed to provide a minimum separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter, except in accordance with FCC multi- transmitter product procedures. End-users must be provided with operating procedures for satisfying RF exposure compliance.

Other Applications from Shenzhen Qianyan Technology LTD

2A7VD-H1771

Govee Wallwash Table Lamp

Aug 13, 2026

Equipment Class

DTS - Digital Transmission System
2A7VD-H7078A

Govee Smart Outdoor Wall Light

Aug 13, 2026

Equipment Class

DTS - Digital Transmission System
2A7VD-H6842

Govee Cone Tree Lights

Aug 13, 2026

Equipment Class

DTS - Digital Transmission System
2A7VD-H70B3

Govee Curtain Lights 2

Aug 06, 2026

Equipment Class

DTS - Digital Transmission System
2A7VD-H5058A

Water Leak Detector 2

Aug 06, 2026

Equipment Class

DTS - Digital Transmission System