Smart Thermo-Hygrometer Model: H5104 User Manual English Deutsch Français Español Italiano 日本語 01 10 19 28 37 46 English Smart Thermo-Hygrometer Comfort Level Temperature Unit Switch /Clear Button Bluetooth connected MAX/MIN Humidity At a Glance 01 Unit Switch/Clear Button Tap to switch temp unit to°C/°F on LCD screen. Press and hold for 3 seconds to clear MAX and MIN records for temp and humidity. Bluetooth-connected Display: Bluetooth is connected. Not shown: Bluetooth isn’t connected. MAX/MIN Maximum/Minimum temp and humidity readings in the past. DRY: COMFORT: WET: Elsewise: Humidity < 30%. 20°C ≤ temp ≤ 26°C. 30% ≤ Humidity ≤ 60% Humidity > 60% No icon. Comfort Level 02 What You Get Accuracy Operating Temp Temp: ±0.3°C /±0.54°F , Humidity: ±3% -20°C-60°C(-4°F-140°F) Smart Thermo- Hygrometer AAA Battery User Manual Service Card SKU 12 2 1 1 4 1 1 H5104001 H5104011 B5104001 B5104011 Specifications 03 Downloading the Govee Home App Download the Govee Home app from the App Store (iOS devices) or Google Play (Android devices). Operating Humidity Bluetooth enabled Distance 0% - 99% 60m/197ft (No obstacles) Place in the battery (Make sure the electrode direction is correct). Preparation Before Using 04 Connecting to Bluetooth Govee Home ❶ ❷ ❸ Turn on Bluetooth in your phone and get close to the Thermo-Hygrometer; (Notice: Android device users should turn on Location and iOS users should tap “Setting - Govee Home - Location - Always” in your phone.) Open Govee Home, tap “+” icon at the top right corner and select “H5104”. Follow instructions in app to complete connecting. 05 Using Your Device with Govee Home App Export data Send historical data to your mailbox in CSV format. Alert me Push alert notifications once temp/humidity goes out of preset range. Calibration Calibration range for the temperature is ±10 °C/±18°F while for the humidity is ±20.0%. ❹ ❺ It shows Bluetooth- connected icon on LCD screen once connection completed. Please check the above steps and try again if connection failed. 06 Troubleshooting ❶ Cannot connect to Bluetooth. a. b. c. d. e. Make sure Bluetooth in your phone has been turned on. Connect to the thermo-hygrometer in the Govee Home app instead of Bluetooth list in your phone. Keep the distance between your phone and the device less than 60m/197ft. Keep your phone as close to the device as possible. Make sure that Android device users turn on Location and iOS users select “Setting - Govee Home - Location - Always” in the phone. ❷ Data in the app is not updated. a.Make sure the device has connnected to the Govee Home app. Troubleshooting 07 Warning ❶ ❷ ❸ ❹ ❺ The device should work in an environment with a temperature ranging from -20°C to 60°Cand humidity from 0% to 99%. Please take out batteries if you don’t use the device for an extended period of time. Prevent dropping the device from the high place. Do not disassemble the device violently. Do not immerse the device in the water. Cannot export data in the app. ❸ Please sign up and log in your account before exporting data. b.Make sure that Android device users turn on Location and iOS users select “Setting - Govee Home - Location - Always” in the phone. 08 Customer Service Warranty: 12-Month Limited Warranty Support: Lifetime Technical Support Email: [email protected] Official Website: www.govee.com @Govee @Govee @Goveeofficial @Govee 09 Deutsch Überblick Komfortstufe Temperatur Geräteschalter / Löschtaste Bluetooth verbunden MAX/MIN Feuchtigkeit Intelligentes Thermo-Hygrometer 10 Bluetooth verbunden Anzeige: Bluetooth ist verbunden Nicht gezeigt: Bluetooth ist nicht verbunden. MAX/MIN Maximale / Minimale Temperatur- und Feuchtigkeitswerte in historischen Aufzeichnun- gen. Komfortstufe DRY: COMFORT: WET: Elsewise: Luftfeuchtigkeit < 30% 20 ≤ Temperatur ≤ 26 , 30% ≤ Luftfeuchtigkeit ≤ 60% Luftfeuchtigkeit > 60% Kein Zeichen. Geräteschalter / Löschtaste Drücken Sie die Taste, um die Temperatur- einheit auf dem LCD-Bildschirm auf ° C / ° F umzuschalten. Halten Sie diese Taste 3 Sekunden lang gedrückt, um die MAX- und MIN-Aufzeichnun- gen für Temperatur und Luftfeuchtigkeit zu löschen. 11 Was Sie bekommen Richtigkeit Btriebs- temperatur Temperatur: ±0.3°C /±0.54°F, Luftfeuchtigkeit: ±3% -20°C-60°C (-4°F-140°F) Die Spezifikation SKU 12 2 1 1 4 1 1 H5104001 H5104011 B5104001 B5104011 Intelligentes Thermo-Hygrometer AAA-Batterie Benutzerhandbuch Servicekarte 12 Vorbereitung vor dem Gebrauch Herunterladen der Govee Home App Legen Sie die Batterie ein (Stellen Sie sicher, dass die Ausrichtung der Elektrode korrektist). Laden Sie die GoveeHome-app aus dem App Store (iOS-Geräte) oder von Google Play (Android-Geräte) herunter. Btriebsfeuchtigkeit Bluetooth fähige Entfernung 0% - 99% 60m/197ft (Keine Hindernisse) 13 Verbindung mit Bluetooth Govee Home Schalten Sie Bluetooth in Ihrem Telefon ein und nähern Sie sich dem Thermo-Hygrometer (Hinweis: Benutzer von Android-Geräten sollten den Standort aktivieren, und iOS-Benutzer sollten in Ihrem Telefon auf "Einstellung - Govee Home - Standort - Immer" tippen.) Öffnen Sie Govee Home, tippen Sie oben rechts auf das Symbol "+" und wählen Sie "H5104". Befolgen Sie die Anweisungen in der App, um die Verbindung abzuschließen. ❶ ❷ ❸ 14 Verwenden Ihres Geräts mit der Govee Home App Daten ausgeben Senden Sie historische Daten im CSV-Format an Ihre Mailbox. Erinnern mich Sobald die Temperatur / Luftfeuchtigkeit den voreingestellten Bereich verlässt, werden Warnmeldungen ausgegeben. Calibration Kalibrierung Der Kalibrierungsbereich für die Temperatur beträgt ±10°C/±18°F , während für die Luftfeuchtigkeit ± 20,0% beträgt. ❹ ❺ Sobald die Verbindung hergestellt ist, wird auf dem LCD-Bildschirm ein Bluetooth-Symbol angezeigt. Bitte überprüfen Sie die obigen Schritte und versuchen Sie noch einmal, wenn die Verbindung fehlgeschlagen ist. 15 Fehlerbehebung ❶ Es kann Verbindung zu Bluetooth nicht hergestellt werden. a. b. c. d. e. Stellen Sie sicher, dass Bluetooth auf Ihrem Telefon aktiviert ist. …
Text truncated - open the document above for the full version.
Shenzhen Qianyan Technology LTD Address: No.3301, Block C, Section 1, Chuangzhi Yuncheng Building, Liuxian Avenue, Xili Community, Xili Street, Nanshan District, Shenzhen, China Email: [email protected] Tel: +86-13632599550 Date: 2023-04-14 FEDERAL COMMUNICATIONS COMMISSIONS Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 To whom it may concern: The RF chip, model FR8016HA, which installed in our product Smart Thermo- Hygrometer monitor Lite, Model: H5104; FCC ID: 2A7VD-H5104. For use in America and this chip only support BLE 1M. The other functions has been shielded by the manufacturer using the software, the end user has no capability to activate it. Sincerely, Signature Xiaopeng Pan / Certification Manager
CFR 47 §2.911(d)(5)(i) Attestation Letter Shenzhen Qianyan Technology LTD Address: No.3301, Block C, Section 1, Chuangzhi Yuncheng Building, Liuxian Avenue, Xili Community, Xili Street, Nanshan District, Shenzhen, China Email: [email protected] Tel: +86-13632599550 Attestation Letter Date: 2023-04-14 FEDERAL COMMUNICATIONS COMMISSIONS Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 Ref: Attestation Statements CFR 47 §2.911(d)(5)(i) Filing FCC ID:2A7VD-H5104 Shenzhen Qianyan Technology LTD certifies that the equipment for which authorization is sought, is not “covered” equipment prohibited from receiving an equipment authorization pursuant to section 2.903 of the FCC rules. Sincerely, Signature Xiaopeng Pan / Certification Manager
CFR 47 §2.911 (d)(5)(ii) Attestation Letter Shenzhen Qianyan Technology LTD Address: No.3301, Block C, Section 1, Chuangzhi Yuncheng Building, Liuxian Avenue, Xili Community, Xili Street, Nanshan District, Shenzhen, China Email: [email protected] Tel: +86-13632599550 Attestation Letter Date: 2023-04-14 FEDERAL COMMUNICATIONS COMMISSIONS Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 Ref: Attestation Statements CFR 47 §2.911(d)(5)(ii) Filing FCC ID:2A7VD-H5104 Shenzhen Qianyan Technology LTD certifies that as of the date of the filing of the application, the applicant is not identified on the Covered List as an entity producing “covered” equipment. Sincerely, Signature Xiaopeng Pan / Certification Manager
U.S. AGENT LETTER OF ATTESTATION Date: 2023-04-14 FEDERAL COMMUNICATIONS COMMISSION Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 Ref: Attestation Statements CFR 47 §2.911(d)(7) Filing FCC ID: 2A7VD-H5104 Shenzhen Qianyan Technology LTD certifies that, as of the date of the filing of the application, GOVEE MOMENTS(US) TRADING LIMITED is our designated U.S. agent for service of process for the above referenced FCC ID. Shenzhen Qianyan Technology LTD accepts to maintain an agent for no less than one year after the grantee has terminated all marketing and importation or the conclusion of any Commission-related proceeding involving the equipment. GOVEE MOMENTS(US) TRADING LIMITED accepts, as of the date of the filing of the application, the obligation of the designated U.S. agent for service of process for the above referenced FCC ID. Designated U.S. Agent Information: Name: GOVEE MOMENTS(US) TRADING LIMITED Address: 2501 Chatham Rd Suite R Springfield IL 62704 FRN: 0033426016 Tel.: 001 (206) 604-2935 Email: [email protected] Signed by (printed name): Tina Liu Signature: Applicant: Shenzhen Qianyan Technology LTD Address: No.3301, Block C, Section 1, Chuangzhi Yuncheng Building, Liuxian Avenue, Xili Community, Xili Street, Nanshan District, Shenzhen, China FRN: 0032478174 Tel: +86-13632599550 Email: [email protected] Signed by (printed name): Xiaopeng Pan Signature:
Shenzhen Qianyan Technology LTD Address: No.3301, Block C, Section 1, Chuangzhi Yuncheng Building, Liuxian Avenue, Xili Community, Xili Street, Nanshan District, Shenzhen, China Email: [email protected] Tel: +86-13632599550 QA-FR-170-B 7/29/2014 FCC Authorization Date: 2023-04-14 FEDERAL COMMUNICATIONS COMMISSIONS Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 Subject: Agent Authorization To whom it may concern: We Shenzhen Qianyan Technology LTD, the undersigned, hereby authorizes Shenzhen Accurate Technology Co., Ltd. to act on its behalf in all matters relating to application for Equipment authorization, including the signing of all documents relating to these matters. All acts carried out by Shenzhen Accurate Technology Co., Ltd. on our behalf shall have the same effect as our own action. We, the undersigned, hereby certify that we are not subject to a denial of federal benefits, that includes FCC benefits, pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C. 862. This authorization is valid until further written notice from the applicant. Sincerely, Signature Xiaopeng Pan / Certification Manager
Shenzhen Qianyan Technology LTD Address: No.3301, Block C, Section 1, Chuangzhi Yuncheng Building, Liuxian Avenue, Xili Community, Xili Street, Nanshan District, Shenzhen, China Email: [email protected] Tel: +86-13632599550 FCC Confidential Authorization Date: 2023-04-14 FEDERAL COMMUNICATIONS COMMISSIONS Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 Subject: Confidentiality Request regarding application for certification of FCC ID: 2A7VD-H5104 In accordance with Sections 0.457 and 0.459 of the Commission’s Rules, Shenzhen Qianyan Technology LTD hereby requests long-term confidential treatment of information accompanying this application as outlined below: Block Diagram Schematics Operation Description As well as short-term confidential treatment of information accompanying this application for a period of 180 days after grant is issued as outlined below: Internal Photos User’s Manual External Photos Test Set-up Photos The above materials contain proprietary and confidential information not customarily released to the public. The public disclosure of these materials provides unjustified benefits to its competitors in the market. Sincerely, Signature Xiaopeng Pan / Certification Manager
Shenzhen Accurate Technology Co., Ltd. FCC ID: 2A7VD-H5104 External Photos Page 1 of 3 External Photos Shenzhen Accurate Technology Co., Ltd. FCC ID: 2A7VD-H5104 External Photos Page 2 of 3 Shenzhen Accurate Technology Co., Ltd. FCC ID: 2A7VD-H5104 External Photos Page 3 of 3
Shenzhen Accurate Technology Co., Ltd. Project No.: RA230320-13283E-RF LABEL AND LOCATION Page 1 of 1 FCC ID Label FCC ID Label Location Information The label shown shall be permanently affixed at a conspicuous location on the device and be readily visible to the user at the time purchase (Labeling requirements per 2.925)
Shenzhen Accurate Technology Co., Ltd. FCC ID: 2A7VD-H5104 Internal Photos Page 1 of 5 Internal photos Shenzhen Accurate Technology Co., Ltd. FCC ID: 2A7VD-H5104 Internal Photos Page 2 of 5 Shenzhen Accurate Technology Co., Ltd. FCC ID: 2A7VD-H5104 Internal Photos Page 3 of 5 Shenzhen Accurate Technology Co., Ltd. FCC ID: 2A7VD-H5104 Internal Photos Page 4 of 5 Shenzhen Accurate Technology Co., Ltd. FCC ID: 2A7VD-H5104 Internal Photos Page 5 of 5 Chip ANT
Shenzhen Accurate Technology Co., Ltd. Report No.: RA230320-13283E-RF Version 140: 2023-01-30 Page 12 of 43 FCC-BLE; RSS-BLE FCC §15.247 (i) & §1.1307 (b) (3) & §2.1091- MPE-Based Exemption Applicable Standard According to subpart 15.247 (i) and subpart 2.1091 systems operating under the provisions of this section shall be operated in a manner that ensures the public is not exposed to RF energy level in excess of the communication guidelines. According to KDB 447498 D04 Interim General RF Exposure Guidance MPE-Based Exemption: General frequency and separation-distance dependent MPE-based effective radiated power(ERP) thresholds are in Table B.1 [Table 1 of § 1.1307(b)(1)(i)(C)] to support an exemptionfrom further evaluation from 300 kHz through 100 GHz. Ris the minimum separation distance in meters f = frequency in MHz Result Mode Frequency (MHz) Tune up conducted power Antenna Gain ERP Evaluation Distance (m) ERP Limit (mW) (dBm) (dBi)(dBd)(dBm)(mW) BLE 2402-2480 10 1 -1.15 8.85 7.6740.2 768 Note: 1.The tune up conducted power and antenna gain was declared by the applicant. 2. 0dBd=2.15dBi To maintain compliance with the FCC’s RF exposure guidelines, place the equipment at least 20cm from nearby persons. Result: Compliant.
Antennatestreport TestLaboratoryDongguanYijiaElectronicCo.,LTD Address No.59MuyuRoad,ShatouCommunity,Chang'anTown,Dongguan City,GuangdongProvince Contact:Mr.Gan13823198410 ModelH5104 1.Testprocedures NameParameterMethodStandardNo. Mobile communication antenna VSWR Genericspecificaitonforantennasusedin themobilecommunications GB/T9410-2008 AntennaGain Radiationpattern Antenna Radiationefficiency IEEEStandardTestProceduresfor Antennas ANSI/IEEEStd149 -1979 2.TestEquipment EquipmentModelNo. Serial No. ManufactureCalibration Date Next calibration Date 24probe Microwave chamber MPS2450Multi- probeOTAme asurementsystems 5*5*5 YJ-PB-F01XH-IOE2022.09.012023.09.01 NetworkAnalyzer ZVB8YJ-RD-15 ROHDE&SCH WARS 2022.08.252023.08.25 Widebandradio Communication tester CMW500YJ-RD-16 ROHDE&SCH WARS 2022.08.252023.08.25 3.DUTSetupPhoto 4.BluetoothAntennaPhysicalSize 5.BluetoothAntennaGain Frequency/MHzGain/dBi 24000.76 24100.76 24200.69 24300.74 24400.64 24500.93 24600.55 24701 24800.55 24900.63 25000.12 6.AntennaPattemPicture 2400MHz 2450MHz 2500MHz Testerby:Wuxianming
Note: This report may contain data that are not covered by the A2LA accreditation and are mar ★ ked with an asterisk “ ”. Shenzhen Accurate Technology Co., Ltd. is not responsible for the authenticity of any test data provided by the applicant. Data included from the applicant that may affect test results are marked with an asterisk ’*’. Customer model name, addresses, names, trademarks etc. are not considered data. This report cannot be reproduced except in full, without prior written approval of the Company. Unless otherwise stated the results shown in this test report refer only to the sample(s) tested. This report is valid only with a valid digital signature. The digital signature may be available only under the Adobe software above version 7.0. Shenzhen Accurate Technology Co., Ltd. 1/F., Building A, Changyuan New Material Port, Science & Industry Park, Nanshan District, Shenzhen, Guangdong, P.R. China Tel: +86 755-26503290 Fax: +86 755-26503290 Web: www.atc-lab.com Version 140: 2023-01-30 Page 1 of 43 FCC-BLE; RSS-BLE TEST REPORT Applicant Name : Shenzhen Qianyan Technology LTD Address : FCC: No.3301, Block C, Section 1, Chuangzhi Yuncheng Building, Liuxian Avenue, Xili Community, Xili Street, Nanshan District, Shenzhen, China IC: No. 3301, Block C, Section 1, Chuangzhi Yuncheng Building, Liuxian Avenue, Xili Community, Xili Street, Nanshan District Shenzhen 518000 China Report Number : RA230320-13283E-RF FCC ID: 2A7VD-H5104 IC: 28789-H5104 Test Standard (s) FCC PART 15.247; RSS-GEN ISSUE 5, FEBRUARY 2021 AMENDMENT 2; RSS-247, ISSUE 2, FEBRUARY 2017 Sample Description Product Type: Smart Thermo-Hygrometer monitor Lite Model No.: H5104 Multiple Model(s) No.: N/A Trade Mark: GoveeLife Date Received: 2023/03/20 Report Date: 2023/04/18 Test Result: Pass* * In the configuration tested, the EUT complied with the standards above. Prepared and Checked By: Approved By: Andy Yu Candy Li EMC Engineer EMC Engineer Shenzhen Accurate Technology Co., Ltd. Report No.: RA230320-13283E-RF Version 140: 2023-01-30 Page 2 of 43 FCC-BLE; RSS-BLE TABLE OF CONTENTS DOCUMENT REVISION HISTORY ......................................................................................................................... 4 GENERAL INFORMATION ....................................................................................................................................... 5 PRODUCT DESCRIPTION FOR EQUIPMENT UNDER TEST (EUT) ..................................................................................... 5 OBJECTIVE ................................................................................................................................................................... 5 TEST METHODOLOGY .................................................................................................................................................. 5 MEASUREMENT UNCERTAINTY .................................................................................................................................... 6 SYSTEM TEST CONFIGURATION .......................................................................................................................... 7 DESCRIPTION OF TEST CONFIGURATION ...................................................................................................................... 7 EQUIPMENT MODIFICATIONS ....................................................................................................................................... 7 EUT EXERCISE SOFTWARE .......................................................................................................................................... 7 DUTY CYCLE ................................................................................................................................................................ 8 SUPPORT EQUIPMENT LIST AND DETAILS .................................................................................................................... 8 EXTERNAL I/O CABLE .................................................................................................................................................. 8 BLOCK DIAGRAM OF TEST SETUP ................................................................................................................................ 9 SUMMARY OF TEST RESULTS ............................................................................................................................. 10 TEST EQUIPMENT LIST ......................................................................................................................................... 11 FCC §15.247 (I) & §1.1307 (B) (3) & §2.1091- MPE-BASED EXEMPTION ........................................................ 12 RSS-102 § 2.5.2 –EXEMPTION LIMITS FOR ROUTINE EVALUATION-RF EXPOSURE EVALUATION 13 APPLICABLE STANDARD ............................................................................................................................................ 13 FCC §15.203 & RSS-GEN §6.8 – ANTENNA REQUIREMENT............................................................................ 14 APPLICABLE STANDARD ............................................................................................................................................ 14 ANTENNA CONNECTOR CONSTRUCTION .................................................................................................................... 14 FCC §15.209, §15.205 & §15.247(D), RSS-GEN § 8.10 & RSS-247 § 5.5 – UNWANTED EMISSION FREQUENCIES AND RESTRICTED BANDS ......................................................................................................... 15 APPLICABLE STANDARD ............................................................................................................................................ 15 EUT SETUP .......................................................................................................................................................…
Text truncated - open the document above for the full version.
Shenzhen Accurate Technology Co., Ltd. Project No.: RA230320-13283E-RF Test Photos Page 1 of 1 Photo of Radiated Emission Measurement (Below 1G) Photo of Radiated Emission Measurement (Above 1G)
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 2.40 GHz - 2.48 GHz | 8.50 mW |
Govee Wallwash Table Lamp
Equipment Class
DTS - Digital Transmission SystemGovee Smart Outdoor Wall Light
Equipment Class
DTS - Digital Transmission SystemGovee Cone Tree Lights
Equipment Class
DTS - Digital Transmission SystemGovee Curtain Lights 2
Equipment Class
DTS - Digital Transmission SystemWater Leak Detector 2
Equipment Class
DTS - Digital Transmission System