Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
ShenzhenQianyanTechnologyLTD No.3301,BlockC,Section1,ChuangzhiYunchengBuilding,LiuxianAvenue,XiliCommunity,XiliStreet, NanshanDistrict,Shenzhen,518000,China 1|Page AttestationStatements To:FederalCommunicationsCommissionDate:Apr.10,26 7435OaklandMillsRoad, Columbia,MD21046,USA Subject:AttestationofCompliancewithFCCCoveredListSoftwareRequirements FCCID:2A7VD-H6046 ProductName:GoveeTVLightBar Thisletterservesasanattestationthattheequipmentidentifiedaboveisnot(selectone)"covered"software asdefinedundertheFederalCommunicationsCommission(FCC)CoveredListrequirements,asoutlined inFCC22-84andKDB986446. Specifically,theundersignedcertifiesthattheequipmentforwhichauthorizationissought: 1.Doesnotcontaincybersecurityoranti-virussoftwareproducedorprovidedbyKasperskyLab, Inc.oranyofitssuccessors,assignees,parents,subsidiaries,affiliates,oranyentitythathasrebranded orrelabeledsoftwareproducedbytheaforementionedentities. 2.Doesnothavethecapabilitytostore,run,ordeliveranysoftwareidentifiedontheFCCCoveredList, includingbutnotlimitedtocybersecurityandanti-virussoftware. Tosupportthisattestation,theappendixevaluationdocumentationhasbeenpreparedandisincludedinthe certificationfiling. Thisattestationisbasedonathoroughevaluationofthedevice'sdesign,functionality,andsoftware environment.Theundersignedaffirmsthattheinformationprovidedisaccurateandcompletetothebestof theirknowledge. Sincerelyyours, PrintedName:XiaopengPan Title:Manager Address:No.3301,BlockC,Section1,ChuangzhiYunchengBuilding,LiuxianAvenue,XiliCommunity,Xili Street,NanshanDistrict,Shenzhen,518000,China Tel.:+86-13632599550 Email:[email protected] ShenzhenQianyanTechnologyLTD No.3301,BlockC,Section1,ChuangzhiYunchengBuilding,LiuxianAvenue,XiliCommunity,XiliStreet, NanshanDistrict,Shenzhen,518000,China 2|Page EvaluationregardingtotheCoveredListSoftware: Compliance Methodology EvaluationProcessResults Deviceis Inherent compliance ☒ TheChipset(s)usedislimitedtorun theCybersecurityoranti-virus software. Compliance ☒ TheMemoryusedislimitedtorunthe Cybersecurityoranti-virussoftware. Compliance ☒ Thereisstoragecapacitylimitationfor storeorinstalltheCybersecurityor anti-virussoftware. Compliance ☒ Operatingsystemusedislimitedto run,installordelivertheCybersecurity oranti-virussoftware. Compliance Deviceisnot Inherent compliance ☐ EvaluationBasedonSoftware BillofMaterials(SBoM) Seeattached“SBoM“ Note:TheSBoMcontentislimited tothescopeofcoveredlist software(e.g.antivirusand cybersecuritysoftware). ☐ EvaluationBasedonScanfor Softwareonthedevice ☐ EvaluationBasedonFilesystemscan ☐ EvaluationBasedonRunning softwarecheck
ShenzhenQianyanTechnologyLTD No.3301,BlockC,Section1,ChuangzhiYunchengBuilding,LiuxianAvenue,XiliCommunity,Xili Street,NanshanDistrict,Shenzhen,518000,China AttestationStatements NotCoveredEntityApplicant&NotCoveredEquipment To:FederalCommunicationsCommissionDate:4/10/2026 7435OaklandMillsRoad, Columbia,MD21046,USA Ref:InformationRequiredbySection2.911(d)(5)(i)&(ii) FCCID:2A7VD-H6046 ShenzhenQianyanTechnologyLTDcertifiesthat,asofthedateofthefilingoftheapplication,the applicantisnotidentifiedontheCoveredList,establishedpursuantto§1.50002ofreferencechapter, asanentityproducing“covered”communicationequipment.Theequipmentforwhichauthorizationis soughtisnot“covered”telecommunicationsequipmentandvideosurveillanceequipmentproducedby entitiesidentifiedontheCommission’sCoveredListthatprohibitedfromreceivinganequipment authorizationpursuanttosection§2.903oftheFCCrules. Sincerelyyours, PrintedName:XiaopengPan Title:Manager Address:No.3301,BlockC,Section1,ChuangzhiYunchengBuilding,LiuxianAvenue,XiliCommunity,Xili Street,NanshanDistrict,Shenzhen,518000,China Tel.:+86-13632599550 Email:[email protected]
-ShenzhenQianyanTechnologyLTD- FederalCommunicationsCommission AuthorizationandEvaluationDivision EquipmentAuthorizationBranch 7435OaklandMillsRoad Columbia,MD21046 4/10/26 U.S.AgentDesignation NameandcompanyofU.S.agent:GOVEEMOMENTS(US)TRADINGLIMITED PhysicalU.S.addressofagent:2501ChathamRdSuiteRSpringfieldIL62704,USA FRNofU.S.agent:0033426016 EmailaddressofU.S.agent:[email protected] [Shenzhen Qianyan Technology LTD]acknowledges their consent for the following contact located in the United States to act as their agent for service of process for the equipment for which authorization is sought (FCC ID:2A7VD-H6046): ContactPhone:(206)604-2935 [GOVEEMOMENTS(US)TRADINGLIMITED]acknowledgestheirobligationtoacceptserviceofprocesson behalfof[ShenzhenQianyanTechnologyLTD]. [ShenzhenQianyanTechnologyLTD]withtheFRN[0032478174]acceptsitsobligationtomaintainanagent forserviceofprocessintheUnitedStatesfornolessthanoneyearaftereitherthegranteehaspermanently terminatedallmarketingandimportationoftheapplicableequipmentwithintheU.S.,ortheconclusionofany Commission-relatedadministrativeorjudicialproceedinginvolvingtheequipment,whicheverislater. Bysigningthisform,weconfirmtheaboveandthatweareawareoftheapplicationrequirementslistedunder§ 2.911(d)(7). TheinformationprovidedinthisletterisbasedonthereferencedrulepartsofTitle47oftheCFRaswellasKDB 986446D01. Anexpirationdateforthisletterdoesnotexist.IncasetheU.S.agentchanges,thegranteeisobligatedtonotify theFCCwithin30daysviathegrantingTCB. Sincerely, Signature [XiaopengPan] [Manager] ContactEmail:[email protected] ContactPhone:+86-13632599550 [ShenzhenQianyanTechnologyLTD] 4 8 _ [ m o d e l ] U S _ A g e n t _ 2 . 9 1 1 ( d ) ( 7 ) - U , V 0 5 -ShenzhenQianyanTechnologyLTD- Signature [JennyYou] [CertificationManager] [GOVEEMOMENTS(US)TRADINGLIMITED]
ShenzhenQianyanTechnologyLTD No.3301,BlockC,Section1,ChuangzhiYunchengBuilding,LiuxianAvenue,Xili Community,XiliStreet,NanshanDistrict,Shenzhen,518000,China 4/10/2026 FederalCommunicationsCommission AuthorizationandEvaluationDivision 7435OaklandMillsRoad Columbia,MD21046 Subject:ConfidentialityRequestfor:FCCID:2A7VD-H6046 PursuanttoSections0.457and0.459oftheCommission’sRules,weherebyrequestpermanent confidentialtreatmentoftheexhibitsaccompanyingthiscertificationapplicationasoutlinedbelow: BlockDiagram Schematics OperationalDescription PartsList Theaboveexhibitscontaintradesecretsand/orproprietaryinformationthatarenotpubliclyavailableand materialsthattheApplicanthasspentconsiderableeffortsindeveloping.Publicdisclosureofthesemay beharmfultotheApplicantandgiveanunfairadvantagetocompetitorsonthemarket. PursuanttoDA04-1705,theapplicantalsorequeststemporaryconfidentialtreatmentoftheexhibits outlinedbelowforaperiodof(upto180)daysfromthedateofequipmentauthorizationandpriorto marketingintheUnitedStatestopreventtheprematurereleaseofanysensitiveinformation.Applicantis awareoftheirresponsibilitytonotifyDERYCOMintheeventinformationregardingtheproductorthe productismadeavailabletothepublicbeforetherequestedperiodhasexpired. UserManual InternalPhotos ExternalPhotos TestSetupPhotos Sincerely, Title:Manager Address:No.3301,BlockC,Section1,ChuangzhiYunchengBuilding,LiuxianAvenue,XiliCommunity, XiliStreet,NanshanDistrict,Shenzhen,518000,China Tel.:+86-13632599550 Email:[email protected]
ShenzhenQianyanTechnologyLTD No.3301,BlockC,Section1,ChuangzhiYunchengBuilding,LiuxianAvenue,XiliCommunity, XiliStreet,NanshanDistrict,Shenzhen,518000,China 2026/4/10 FederalCommunicationsCommission AuthorizationandEvaluationDivision 7435OaklandMillsRoad Columbia,MD21046 Subject:AgentAuthorizationforFCCID:2A7VD-H6046 I,theundersigned,herebyauthorize(ShenzhenAnbotekComplianceLaboratoryLimited.)toactonour behalfinallmattersrelatingtothisapplicationforequipmentcertification. Anyactcarriedoutby(ShenzhenAnbotekComplianceLaboratoryLimited.)shallhavethesameeffectas ourownandIacknowledgethatallresponsibilityforcomplyingwiththetermsandconditionsof certification,asspecifiedbyDERYCOMCERTIFICATIONSERVICES,INC.,stillresideswith(Shenzhen QianyanTechnologyLTD). WecertifythatwearenotsubjecttoadenialoffederalbenefitsthatincludesFCCbenefitspursuantto Section5301oftheAnti-DrugAbuseActof1988,21U.S.C.§862,andthatnopartytotheapplication,as definedin47CFR§1.2002(b),issubjecttoadenialoffederalbenefitsthatincludesFCCbenefits pursuanttothatsection. Sincerely, PrintedName:XiaopengPan Title:Manager Tel.:+86-13632599550 Fax:0755-23739351 Email:[email protected]
L Label:(Size: 4cm* 2cm) abelLocationOnEUT Confirmtheuseofrealappearancephotosasreferences
RFEXPOSUREEVALUATION KDB447498D01MobileandPortableDevicesRFExposureProceduresand EquipmentAuthorizationPoliciesv06. AccordingtoFCC1.1310:Thecriterialistedinthefollowingtableshallbeused toevaluatetheenvironmentimpactofhumanexposuretoradiofrequency(RF) Radiationasspecifiedin§1.1307(b) EUTSpecification FCCID2A7VD-H6046 EUT GoveeTVLightBar Frequencyband(Operating)BT:2.402GHz~2.480GHz WLAN:2.412GHz~2.462GHz RLAN:5.180GHz~5.240GHz RLAN:5.260GHz~5.320GHz RLAN: 5.500 GHz~ 5.700 GHz RLAN:5.745GHz~5.825GHz Others: DevicecategoryPortable(<20cmseparation) Mobile(>20cmseparation) Others___ ExposureclassificationOccupational/Controlledexposure(S=5mW/cm2) GeneralPopulation/Uncontrolledexposure(S=1mW/cm2) AntennadiversitySingleantenna Multipleantennas Txdiversity Rxdiversity Tx/Rxdiversity Antennagain(Max)BT:2.45dBi Wi-Fi2.4G:3.98dBi EvaluationappliedMPEEvaluation SAREvaluation LimitsforMaximumPermissibleExposure(MPE) Frequency Range(MHz) ElectricField Strength(V/m) MagneticField Strength(A/m) Power Density(mW/cm 2 ) Average Time (A)LimitsforOccupational/ControlExposures 300-1500----F/3006 1500-100000----56 (B)LimitsforGeneralPopulation/UncontrolExposures 300-1500----F/15006 1500-100000----130 Friistransmissionformula:Pd=(Pout*G)\(4*pi*R2) Where Pd=PowerdensityinmW/cm 2 Pout=outputpowertoantennainMw G=gainofantennainlinearscale Pi=3.1416 R=distancebetweenobservationpointandcenteroftheradiatorincm PdthelimitofMPE,1mW/cm2.Ifweknowthemaximumgainoftheantenna andtotalpowerinputtotheantenna,throughthecalculation,wewillknowthe distancewheretheMPElimitisreached. MaxMeasurementResult OperatingMode Measured Power Tuneup tolerance Max.Tune upPower Antenna Gain Power densityat 20cm Power densityLimits (mW/cm 2 ) (dBm)(dBm)(dBm)(dBi)(mW/cm 2 ) BLE0.400.40±11.402.450.00051 WiFi2.4G14.4114.41±115.413.980.01731 TheMaximumsimultaneoustransmissionforBLE+WiFi2.4GANT2: =S BLE /S limit-2.4 +S WLANANT2 /S limit-2.4 =0.0005/1+0.0173/1 =0.0178 <1.0 Result:PASS.
ReportNo.:1812C60051812501-01 Page 1 of 22 AppendixTestData ReportNo.:1812C60051812501-01TestSampleNo.:1-2-2 StartTestDate:2026-1-20FinishTestDate:2026-1-28 TestEngineer:Auditor: Temperature: 22.1°C RelativeHumidity:61% Pressure:101kPa AppendixA:6dBBandwidth TestResult Test Mode AntennaFrequency[MHz] 6dBBW [MHz] FL[MHz]FH[MHz]Limit[MHz]Verdict BLE_1MAnt124020.7362401.6362402.3720.5PASS BLE_1MAnt124400.6282439.7002440.3280.5PASS BLE_1MAnt124800.6562479.6682480.3240.5PASS ReportNo.:1812C60051812501-01 Page 2 of 22 TestGraphs BLE_1M-Ant1-2402-PASS BLE_1M-Ant1-2440-PASS ReportNo.:1812C60051812501-01 Page 3 of 22 BLE_1M-Ant1-2480-PASS ReportNo.:1812C60051812501-01 Page 4 of 22 AppendixB:99%OccupiedBandwidth TestResult Test Mode AntennaFrequency[MHz] OCB [MHz] FL[MHz]FH[MHz]Limit[MHz]Verdict BLE_1MAnt124021.08562401.46672402.5523------ BLE_1MAnt124401.01542439.50282440.5182------ BLE_1MAnt124801.01762479.50282480.5204------ ReportNo.:1812C60051812501-01 Page 5 of 22 TestGraphs BLE_1M-Ant1-2402 BLE_1M-Ant1-2440 ReportNo.:1812C60051812501-01 Page 6 of 22 BLE_1M-Ant1-2480 ReportNo.:1812C60051812501-01 Page 7 of 22 AppendixC:Maximumconductedoutputpower TestResultPeak Test Mode Antenna Frequency [MHz] Conducted Peak Power[dBm] Conducted Limit[dBm] Verdict BLE_1MAnt124020.40≤30PASS BLE_1MAnt124400.05≤30PASS BLE_1MAnt12480-0.40≤30PASS TestGraphsPeak BLE_1M-Ant1-2402-PASS ReportNo.:1812C60051812501-01 Page 8 of 22 BLE_1M-Ant1-2440-PASS BLE_1M-Ant1-2480-PASS ReportNo.:1812C60051812501-01 Page 9 of 22 AppendixD:Maximumpowerspectraldensity TestResult TestModeAntennaFrequency[MHz]Result[dBm/30kHz]Limit[dBm/3kHz]Verdict BLE_1MAnt12402-14.50≤8.00PASS BLE_1MAnt12440-13.87≤8.00PASS BLE_1MAnt12480-14.59≤8.00PASS ReportNo.:1812C60051812501-01 Page 10 of 22 TestGraphs BLE_1M-Ant1-2402-PASS BLE_1M-Ant1-2440-PASS ReportNo.:1812C60051812501-01 Page 11 of 22 BLE_1M-Ant1-2480-PASS ReportNo.:1812C60051812501-01 Page 12 of 22 AppendixE:Bandedgemeasurements TestResult Test Mode AntennaChName Frequency [MHz] RefLevel [dBm] Result [dBm] Limit [dBm] Verdict BLE_1MAnt1Low2402-0.74-53.6≤-20.74PASS BLE_1MAnt1High2480-1.39-56.91≤-21.39PASS ReportNo.:1812C60051812501-01 Page 13 of 22 TestGraphs BLE_1M-Ant1-2402-PASS BLE_1M-Ant1-2480-PASS ReportNo.:1812C60051812501-01 Page 14 of 22 AppendixF:ConductedSpuriousEmission TestResult Test Mode Antenna Frequency [MHz] Freq.Range [MHz] Ref. Level [dBm] Result [dBm] Limit [dBm] Verdict BLE_1MAnt124020~Reference-0.59-0.59---PASS BLE_1MAnt1240230~1000-0.59-59.12≤-20.59PASS BLE_1MAnt124021000~26500-0.59-39.54≤-20.59PASS BLE_1MAnt124400~Reference-0.86-0.86---PASS BLE_1MAnt1244030~1000-0.86-58.92≤-20.86PASS BLE_1MAnt124401000~26500-0.86-39.21≤-20.86PASS BLE_1MAnt124800~Reference-1.46-1.46---PASS BLE_1MAnt1248030~1000-1.46-59.19≤-21.46PASS BLE_1MAnt124801000~26500-1.46-38.98≤-21.46PASS Remark:Regardingthespuriousemissionsfrom30MHzto26.5GHz,thecablelosshavebeensetinthe 'InputCorrection'oftheSpectrumAnalyzerduringthetest. ReportNo.:1812C60051812501-01 Page 15 of 22 TestGraphs BLE_1M-Ant1-2402-0~Reference-PASS BLE_1M-Ant1-2402-30~1000-PASS ReportNo.:1812C60051812501-01 Page 16 of 22 BLE_1M-Ant1-2402-1000~26500-PASS BLE_1M-Ant1-2440-0~Reference-PASS ReportNo.:1812C60051812501-01 Page 17 of 22 BLE_1M-Ant1-2440-30~1000-PASS BLE_1M-Ant1-2440-1000~26500-PASS ReportNo.:1812C60051812501-01 Page 18 of 22 BLE_1M-Ant1-2480-0~Reference-PASS BLE_1M-Ant1-2480-30~1000-PASS ReportNo.:1812C60051812501-01 Page 19 of 22 BLE_1M-Ant1-2480-1000~26500-PASS ReportNo.:1812C60051812501-01 Page 20 of 22 AppendixG:DutyCycle TestResult Test Mode Antenna Frequency [MHz] ONTime [ms] Period [ms] DutyCycle [%] DutyCycle Factor[dB] BLE_1MAnt1240220.0020.00100.000.00 BLE_1MAnt1244020.0020.00100.000.00 BLE_1MAnt1248020.0020.00100.000.00 ReportNo.:1812C60051812501-01 Page 21 of 22 TestGraphs NTNV-BLE_1M-Ant1-2402 NTNV-BLE_1M-Ant1-2440 ReportNo.:1812C60051812501-01 Page 22 of 22 NTNV-BLE_1M-Ant1-2480 ---End---
ReportNo.:1812C60051812502-01 Page 1 of 49 AppendixTestData ReportNo.:1812C60051812502-01TestSampleNo.:1-2-2 StartTestDate:2026-1-20FinishTestDate:2026-1-28 TestEngineer:Auditor: Temperature: 22.1°C RelativeHumidity:61% Pressure:101kPa AppendixA:6dBBandwidth TestResult TestModeAntennaFrequency[MHz] 6dBBW [MHz] FL[MHz]FH[MHz]Limit[MHz]Verdict 11BAnt124128.2402407.9202416.1600.5PASS 11BAnt124378.2402432.9202441.1600.5PASS 11BAnt124628.2402457.9202466.1600.5PASS 11GAnt1241216.0402404.0002420.0400.5PASS 11GAnt1243716.0402429.1202445.1600.5PASS 11GAnt1246216.0402454.0802470.1200.5PASS 11N20SISOAnt1241217.3202403.4002420.7200.5PASS 11N20SISOAnt1243717.3202428.4802445.8000.5PASS 11N20SISOAnt1246217.3602453.3202470.6800.5PASS ReportNo.:1812C60051812502-01 Page 2 of 49 TestGraphs 11B-Ant1-2412-PASS 11B-Ant1-2437-PASS ReportNo.:1812C60051812502-01 Page 3 of 49 11B-Ant1-2462-PASS 11G-Ant1-2412-PASS ReportNo.:1812C60051812502-01 Page 4 of 49 11G-Ant1-2437-PASS 11G-Ant1-2462-PASS ReportNo.:1812C60051812502-01 Page 5 of 49 11N20SISO-Ant1-2412-PASS 11N20SISO-Ant1-2437-PASS ReportNo.:1812C60051812502-01 Page 6 of 49 11N20SISO-Ant1-2462-PASS ReportNo.:1812C60051812502-01 Page 7 of 49 AppendixB:99%OccupiedBandwidth TestResult TestModeAntenna Channel Frequency[MHz] OCB [MHz] FL[MHz]FH[MHz]Limit[MHz]Verdict 11BAnt1241212.8792405.62592418.5049------ 11BAnt1243712.8132430.69132443.5043------ 11BAnt1246212.7902455.72412468.5141------ 11GAnt1241216.8482403.64702420.4950------ 11GAnt1243716.8272428.66672445.4937------ 11GAnt1246216.8722453.69732470.5693------ 11N20SISOAnt1241217.8512403.12002420.9710------ 11N20SISOAnt1243717.8352428.13402445.9690------ 11N20SISOAnt1246217.8172453.17442470.9914------ ReportNo.:1812C60051812502-01 Page 8 of 49 TestGraphs 11B-Ant1-2412 11B-Ant1-2437 ReportNo.:1812C60051812502-01 Page 9 of 49 11B-Ant1-2462 11G-Ant1-2412 ReportNo.:1812C60051812502-01 Page 10 of 49 11G-Ant1-2437 11G-Ant1-2462 ReportNo.:1812C60051812502-01 Page 11 of 49 11N20SISO-Ant1-2412 11N20SISO-Ant1-2437 ReportNo.:1812C60051812502-01 Page 12 of 49 11N20SISO-Ant1-2462 ReportNo.:1812C60051812502-01 Page 13 of 49 AppendixC:Maximumconductedoutputpower TestResultAverage Test Mode AntennaFrequency[MHz] Result [dBm] Limit [dBm] Verdict 11BAnt1241214.41≤30.00PASS 11BAnt1243713.65≤30.00PASS 11BAnt1246213.08≤30.00PASS 11GAnt1241214.09≤30.00PASS 11GAnt1243713.58≤30.00PASS 11GAnt1246212.78≤30.00PASS 11N20SISOAnt1241213.91≤30.00PASS 11N20SISOAnt1243713.41≤30.00PASS 11N20SISOAnt1246212.62≤30.00PASS Note:Thecablelossarecompensatedinthegraph. ReportNo.:1812C60051812502-01 Page 14 of 49 TestGraphsAverage 11B-Ant1-2412-PASS 11B-Ant1-2437-PASS ReportNo.:1812C60051812502-01 Page 15 of 49 11B-Ant1-2462-PASS 11G-Ant1-2412-PASS ReportNo.:1812C60051812502-01 Page 16 of 49 11G-Ant1-2437-PASS 11G-Ant1-2462-PASS ReportNo.:1812C60051812502-01 Page 17 of 49 11N20SISO-Ant1-2412-PASS 11N20SISO-Ant1-2437-PASS ReportNo.:1812C60051812502-01 Page 18 of 49 11N20SISO-Ant1-2462-PASS ReportNo.:1812C60051812502-01 Page 19 of 49 AppendixD:Maximumpowerspectraldensity TestResult Test Mode Antenna Frequency [MHz] Result[dBm/30kHz]Limit[dBm/3kHz]Verdict 11BAnt12412-6.81≤8.00PASS 11BAnt12437-7.50≤8.00PASS 11BAnt12462-7.75≤8.00PASS 11GAnt12412-9.59≤8.00PASS 11GAnt12437-9.95≤8.00PASS 11GAnt12462-10.85≤8.00PASS 11N20SIS O Ant12412-9.79≤8.00PASS 11N20SIS O Ant12437-10.43≤8.00PASS 11N20SIS O Ant12462-10.87≤8.00PASS Note: 1.Thecablelossarecompensatedinthegraph. ReportNo.:1812C60051812502-01 Page 20 of 49 TestGraphs 11B-Ant1-2412-PASS 11B-Ant1-2437-PASS ReportNo.:1812C60051812502-01 Page 21 of 49 11B-Ant1-2462-PASS 11G-Ant1-2412-PASS ReportNo.:1812C60051812502-01 Page 22 of 49 11G-Ant1-2437-PASS 11G-Ant1-2462-PASS ReportNo.:1812C60051812502-01 Page 23 of 49 11N20SISO-Ant1-2412-PASS 11N20SISO-Ant1-2437-PASS ReportNo.:1812C60051812502-01 Page 24 of 49 11N20SISO-Ant1-2462-PASS ReportNo.:1812C60051812502-01 Page 25 of 49 AppendixE:ConductedBandedge TestResult TestModeAntenna Ch. Name Frequency[MHz] Ref. Level[dBm] Result[dBm]Limit[dBm]Verdict 11BAnt1Low24125.62-44.2≤-24.38PASS 11BAnt1High24625.23-54.58≤-24.77PASS 11GAnt1Low24120.80-33.5≤-29.2PASS 11GAnt1High2462-0.24-48.47≤-30.24PASS 11N20SISOAnt1Low24120.61-33.46≤-29.39PASS 11N20SISOAnt1High2462-0.90-47.06≤-30.9PASS ReportNo.:1812C60051812502-01 Page 26 of 49 TestGraphs 11B-Ant1-2412-PASS 11B-Ant1-2462-PASS ReportNo.:1812C60051812502-01 Page 27 of 49 11G-Ant1-2412-PASS 11G-Ant1-2462-PASS ReportNo.:1812C60051812502-01 Page 28 of 49 11N20SISO-Ant1-2412-PASS 11N20SISO-Ant1-2462-PASS ReportNo.:1812C60051812502-01 Page 29 of 49 AppendixF:ConductedSpuriousEmission TestResult TestModeAntennaFrequency[MHz] Freq.Range [Mhz] Ref. Level [dBm] Result [dBm] Limit [dBm] Verdict 11BAnt124120~Reference6.536.53---PASS 11BAnt1241230~10006.53-59.41≤-23.47PASS 11BAnt124121000~265006.53-43.81≤-23.47PASS 11BAnt124370~Reference5.565.56---PASS 11BAnt1243730~10005.56-59.24≤-24.44PASS 11BAnt124371000~265005.56-45.91≤-24.44PASS 11BAnt124620~Reference4.784.78---PASS 11BAnt1246230~10004.78-58.82≤-25.22PASS 11BAnt124621000~265004.78-48.64≤-25.22PASS 11GAnt124120~Reference0.850.85---PASS 11GAnt1241230~10000.85-59.25≤-29.15PASS 11GAnt124121000~265000.85-49.01≤-29.15PASS 11GAnt124370~Reference0.390.39---PASS 11GAnt1243730~10000.39-59.1≤-29.61PASS 11GAnt124371000~265000.39-49.08≤-29.61PASS 11GAnt124620~Reference-0.58-0.58---PASS 11GAnt1246230~1000-0.58-59.24≤-30.58PASS 11GAnt124621000~26500-0.58-48.56≤-30.58PASS 11N20SISOAnt124120~Reference0.370.37---PASS 11N20SISOAnt1241230~10000.37-58.89≤-29.63PASS 11N20SISOAnt124121000~265000.37-48.69≤-29.63PASS 11N20SISOAnt124370~Reference0.100.10---PASS 11N20SISOAnt1243730~10000.10-59.28≤-29.9PASS 11N20SISOAnt124371000~265000.10-48.21≤-29.9PASS 11N20SISOAnt124620~Reference-0.59-0.59---PASS 11N20SISOAnt1246230~1000-0.59-58.3≤-30.59PASS 11N20SISOAnt124621000~26500-0.59-48.82≤-30.59PASS Remark:Regardingthespuriousemissionsfrom30MHzto26.5GHz,thecablelosshavebeensetinthe 'InputCorrection'oftheSpectrumAnalyzerduringthe…
Text truncated - open the document above for the full version.
Antennatestreport TestLaboratoryDongguanYijiaElectronicCo.,LTD Address No.59MuyuRoad,ShatouCommunity,Chang'anTown,Dongguan City,GuangdongProvince Contact:Mr.Gan13823198410 ModelH6046 1.Testprocedures NameParameterMethodStandardNo. Mobile communication antenna VSWR Genericspecificaitonforantennasusedin themobilecommunications GB/T9410-2008 AntennaGain Radiationpattern Antenna Radiationefficiency IEEEStandardTestProceduresfor Antennas ANSI/IEEEStd149 -1979 2.TestEquipment EquipmentModelNo. Serial No. ManufactureCalibration Date Next calibration Date 24probe Microwave chamber MPS2450Multi- probeOTAme asurementsystems 5*5*5 YJ-PB-F01XH-IOE2025.08.252026.08.25 NetworkAnalyzer ZVB8YJ-RD-15 ROHDE&SCH WARS 2025.08.252026.08.25 Widebandradio Communication tester CMW500YJ-RD-16 ROHDE&SCH WARS 2025.08.252026.08.25 3.DUTSetupPhoto 4.BluetoothAntennaPhysicalSize 5.WIFIAntennaPhysicalSize 6.Bluetooth&WiFiAntennaType&Gain Type:PCB Frequency/MHzBTGain/dBiWiFiGain/dBi 24002.33.98 24102.413.85 24202.433.46 24302.353.03 24402.082.5 24502.382.63 24601.992.83 24702.363.03 24802.143.17 24902.453.11 25002.242.97 BT: WiFi: 7.BluetoothAntennaPatternPicture 2400MHz 2450MHz 2500MHz 8.WiFiAntennaPatternPicture 2400MHz 2450MHz 2500MHz Testerby:Wuxianming
Page 1 of 31 FCC Test Report Report No.:1812C60051812501 Applicant:Shenzhen Qianyan Technology LTD Address: No. 3301, Block C, Section 1, Chuangzhi Yuncheng Building, Liuxian Avenue, Xili Community, Xili Street, Nanshan District, Shenzhen, 518000, China Product Name:Govee TV Light Bar Report Date:2026-04-10 Shenzhen Anbotek Compliance Laboratory Limited #检测章# #资质章# #报告二维码# Report No.:1812C60051812501Page 2 of 31 FCC ID: 2A7VD-H6046 Contents 1. General Information ...............................................................................................................................6 1.1. Client Information ........................................................................................................................6 1.2. Description of Device (EUT) ........................................................................................................6 1.3. Auxiliary Equipment Used During Test........................................................................................7 1.4. Operation channel list..................................................................................................................7 1.5. Description of Test Modes...........................................................................................................7 1.6. Measurement Uncertainty ...........................................................................................................8 1.7. Additional Instructions .................................................................................................................8 1.8. Test Summary .............................................................................................................................9 1.9. Description of Test Facility ........................................................................................................10 1.10. Disclaimer................................................................................................................................10 1.11. Test Equipment List.................................................................................................................11 2. Antenna requirement ...........................................................................................................................13 2.1. Conclusion.................................................................................................................................13 3. Conducted Emission at AC power line ................................................................................................14 3.1. EUT Operation ..........................................................................................................................14 3.2. Test Setup .................................................................................................................................14 3.3. Test Data ...................................................................................................................................15 4. 6dB Bandwidth ....................................................................................................................................17 4.1. EUT Operation ..........................................................................................................................17 4.2. Test Setup .................................................................................................................................17 4.3. Test Data ...................................................................................................................................17 5. Maximum Conducted Output Power....................................................................................................18 5.1. EUT Operation ..........................................................................................................................18 5.2. Test Setup .................................................................................................................................18 5.3. Test Data ...................................................................................................................................18 6. Power Spectral Density .......................................................................................................................19 6.1. EUT Operation ..........................................................................................................................19 6.2. Test Setup .................................................................................................................................19 6.3. Test Data ...................................................................................................................................19 7. Emissions in non-restricted frequency bands ......................................................................................20 7.1. EUT Operation ..........................................................................................................................20 7.2. Test Setup .................................................................................................................................20 7.3. Test Data ...................................................................................................................................20 8. Band edge emissions (Radiated) ........................................................................................................21 8.1. EUT Operation ..........................................................................................................................21 8.2. Test Setup .................................................................................................................................21 8.3. Test Data ...................................................................................................................................22 9. Emissions in restricted frequency bands (below 1GHz) …
Text truncated - open the document above for the full version.
Page 1 of 35 FCC Test Report Report No.:1812C60051812502 Applicant:Shenzhen Qianyan Technology LTD Address: No. 3301, Block C, Section 1, Chuangzhi Yuncheng Building, Liuxian Avenue, Xili Community, Xili Street, Nanshan District, Shenzhen, 518000, China Product Name:Govee TV Light Bar Report Date:2026-04-10 Shenzhen Anbotek Compliance Laboratory Limited #检测章# #资质章# #报告二维码# Report No.:1812C60051812502Page 2 of 35 FCC ID: 2A7VD-H6046 Contents 1. General Information ...............................................................................................................................6 1.1. Client Information ........................................................................................................................6 1.2. Description of Device (EUT) ........................................................................................................6 1.3. Auxiliary Equipment Used During Test........................................................................................7 1.4. Operation channel list..................................................................................................................7 1.5. Description of Test Modes...........................................................................................................7 1.6. Measurement Uncertainty ...........................................................................................................7 1.7. Additional Instructions .................................................................................................................8 1.8. Test Summary .............................................................................................................................8 1.9. Description of Test Facility ..........................................................................................................9 1.10. Disclaimer..................................................................................................................................9 1.11. Test Equipment List.................................................................................................................10 2. Antenna requirement ...........................................................................................................................12 2.1. Conclusion.................................................................................................................................12 3. Conducted Emission at AC power line ................................................................................................13 …
Text truncated - open the document above for the full version.
2501 Chatham Rd Suite R · Springfield, Illinois, 62704 · United States
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 2.40 GHz - 2.48 GHz | 1.10 mW |
| 2 | 15C | 2.41 GHz - 2.46 GHz | 27.60 mW |
Govee Wallwash Table Lamp
Equipment Class
DTS - Digital Transmission SystemGovee Smart Outdoor Wall Light
Equipment Class
DTS - Digital Transmission SystemGovee Cone Tree Lights
Equipment Class
DTS - Digital Transmission SystemGovee Curtain Lights 2
Equipment Class
DTS - Digital Transmission SystemWater Leak Detector 2
Equipment Class
DTS - Digital Transmission System