FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Shenzhen Qianyan Technology LTD/
  3. 2A7VD-H7057

2A7VD-H7057Govee Outdoor Flood Lights 2

Shenzhen Qianyan Technology LTD

Application Details

Equipment Class
DTS - Digital Transmission System
Date of Grant
Sep 16, 2024
Application Purpose
Original Equipment
Date of Application
Sep 16, 2024
Equipment Note
Govee Outdoor Flood Lights 2
Frequency Range
2412.00000000 - 2462.00000000
Company
Shenzhen Qianyan Technology LTD
Country
China

Documents & Files

Select a file to view

Attestation Statements

↗
↗
↗
↗

Cover Letter(s)

↗
↗
↗

ID Label/Location Info

↗
↗

RF Exposure Info

↗

Test Report

↗
↗
↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Attestation Statements

Shenzhen Qianyan Technology LTD Address: No.3301, Block C, Section 1, Chuangzhi Yuncheng Building, Liuxian Avenue, Xili Community, Xili Street, Nanshan District, Shenzhen, China Email: [email protected] Tel: +86-13632599550 Date: 2024-08-08 FEDERAL COMMUNICATIONS COMMISSIONS Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 To whom it may concern: Our product Govee Outdoor Flood Lights 2, Model: H 7058, H7057; FCC ID: 2A7VD-H7057. For use in America, this product only support BLE 1M, 2.4G Wi-Fi (2412-2462MHz, 802.11b/g/n-HT20 mode). The other functions, bands and modes has been shielded by the manufacturer using the software, the end user has no capability to activate it. Sincerely, Signature Xiaopeng Pan / Certification Manager

Attestation Statements

CFR 47 §2.911(d)(5)(i) Attestation Letter Shenzhen Qianyan Technology LTD Address: No.3301, Block C, Section 1, Chuangzhi Yuncheng Building, Liuxian Avenue, Xili Community, Xili Street, Nanshan District, Shenzhen, China Email: [email protected] Tel: +86-13632599550 Attestation Letter Date: 2024-08-06 FEDERAL COMMUNICATIONS COMMISSIONS Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 Ref: Attestation Statements CFR 47 §2.911(d)(5)(i) Filing FCC ID:2A7VD-H7057 Shenzhen Qianyan Technology LTD certifies that the equipment for which authorization is sought, is not “covered” equipment prohibited from receiving an equipment authorization pursuant to section 2.903 of the FCC rules. Sincerely, Signature Xiaopeng Pan / Certification Manager

Attestation Statements

CFR 47 §2.911 (d)(5)(ii) Attestation Letter Shenzhen Qianyan Technology LTD Address: No.3301, Block C, Section 1, Chuangzhi Yuncheng Building, Liuxian Avenue, Xili Community, Xili Street, Nanshan District, Shenzhen, China Email: [email protected] Tel: +86-13632599550 Attestation Letter Date: 2024-08-06 FEDERAL COMMUNICATIONS COMMISSIONS Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 Ref: Attestation Statements CFR 47 §2.911(d)(5)(ii) Filing FCC ID:2A7VD-H7057 Shenzhen Qianyan Technology LTD certifies that as of the date of the filing of the application, the applicant is not identified on the Covered List as an entity producing “covered” equipment. Sincerely, Signature Xiaopeng Pan / Certification Manager

Attestation Statements

U.S. AGENT LETTER OF ATTESTATION Date: 2024-08-06 FEDERAL COMMUNICATIONS COMMISSION Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 Ref: Attestation Statements CFR 47 §2.911(d)(7) Filing FCC ID: 2A7VD-H7057 Shenzhen Qianyan Technology LTD certifies that, as of the date of the filing of the application, GOVEE MOMENTS(US) TRADING LIMITED is our designated U.S. agent for service of process for the above referenced FCC ID. Shenzhen Qianyan Technology LTD accepts to maintain an agent for no less than one year after the grantee has terminated all marketing and importation or the conclusion of any Commission-related proceeding involving the equipment. GOVEE MOMENTS(US) TRADING LIMITED accepts, as of the date of the filing of the application, the obligation of the designated U.S. agent for service of process for the above referenced FCC ID. Designated U.S. Agent Information: Name: GOVEE MOMENTS(US) TRADING LIMITED Address: 2501 Chatham Rd Suite R Springfield IL 62704 FRN: 0033426016 Tel.: 001 (206) 604-2935 Email: [email protected] Signed by (printed name): Jenny You Signature: Applicant: Shenzhen Qianyan Technology LTD Address: No.3301, Block C, Section 1, Chuangzhi Yuncheng Building, Liuxian Avenue, Xili Community, Xili Street, Nanshan District, Shenzhen, China FRN: 0032478174 Tel: +86-13632599550 Email: [email protected] Signed by (printed name): Xiaopeng Pan Signature:

Cover Letter(s)

Shenzhen Qianyan Technology LTD Address: No.3301, Block C, Section 1, Chuangzhi Yuncheng Building, Liuxian Avenue, Xili Community, Xili Street, Nanshan District, Shenzhen, China Email: [email protected] Tel: +86-13632599550 QA-FR-170-B 7/29/2014 FCC Authorization Date: 2024-08-06 FEDERAL COMMUNICATIONS COMMISSIONS Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 Subject: Agent Authorization To whom it may concern: We, Shenzhen Qianyan Technology LTD, the undersigned, hereby authorizes World Alliance Testing & Certification (Shenzhen) Co., Ltd to act on its behalf in all matters relating to application for Equipment authorization, including the signing of all documents relating to these matters. All acts carried out by World Alliance Testing & Certification (Shenzhen) Co., Ltd on our behalf shall have the same effect as our own action. We, the undersigned, hereby certify that we are not subject to a denial of federal benefits, that includes FCC benefits, pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C. 862. This authorization is valid until further written notice from the applicant. Sincerely Yours, Signature: Xiaopeng Pan / Certification Manager

Cover Letter(s)

Shenzhen Qianyan Technology LTD Address: No.3301, Block C, Section 1, Chuangzhi Yuncheng Building, Liuxian Avenue, Xili Community, Xili Street, Nanshan District, Shenzhen, China Email: [email protected] Tel: +86-13632599550 FCC Confidential Authorization Date: 2024-08-06 FEDERAL COMMUNICATIONS COMMISSIONS Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 Subject: Confidentiality Request regarding application for certification of FCC ID: 2A7VD-H7057 In accordance with Sections 0.457 and 0.459 of the Commission’s Rules, Shenzhen Qianyan Technology LTD hereby requests long-term confidential treatment of information accompanying this application as outlined below: • Block Diagram • Schematics • Operation Description As well as short-term confidential treatment of information accompanying this application for a period of 180 days after grant is issued as outlined below: • Internal Photos • User’s Manual • External Photos • Test Set-up Photos The above materials contain proprietary and confidential information not customarily released to the public. The public disclosure of these materials provides unjustified benefits to its competitors in the market. Sincerely, Signature Xiaopeng Pan / Certification Manager

Cover Letter(s)

Shenzhen Qianyan Technology LTD Address: No.3301, Block C, Section 1, Chuangzhi Yuncheng Building, Liuxian Avenue, Xili Community, Xili Street, Nanshan District, Shenzhen, China Email: [email protected] Tel: +86-13632599550 Date: 2024-08-06 Declaration of Similarity FEDERAL COMMUNICATIONS COMMISSIONS Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 To Whom It May Concern, We, Shenzhen Qianyan Technology LTD hereby declare that there are some differences between our Multiple Models and testing products. Details as below: Products Description Name Govee Outdoor Flood Lights 2 FCC ID:2A7VD-H7057 Differences Description Tested Model Multiple Models Differences Details H7058 H7057 Rated input &Number of light H7058: Input: DC 24V, 3.0A Number of light: 6pcs H7057: Input: DC 24V, 2.0A Number of light: 4pcs Note: All of the models are electrically identical. We guarantee all the information provided above is true, and notice that we’ll bear all the consequences caused by any false information or concealing. Best Regards, Sincerely, Signature: Xiaopeng Pan / Certification Manager

ID Label/Location Info

48 93 33 23 6 Shenzhen Qianyan Technology LTD Govee Outdoor Flood Lights 2 Light Color: RGBWWModel: H7057 HVIN: H7057FCC ID: 2A7VD-H7057 CAN ICES-005(B)/NMB-005(B) SN: Made In China IC: 28789-H7057INPUT: 24V 2A

ID Label/Location Info

48 93 33 23 6 Shenzhen Qianyan Technology LTD Govee Outdoor Flood Lights 2 Light Color: RGBWWModel: H7058 HVIN: H7058FCC ID: 2A7VD-H7057 CAN ICES-005(B)/NMB-005(B) SN: Made In China IC: 28789-H7057INPUT: 24V 3A

RF Exposure Info

Report No.: 2405U81213EG Report Template: TR-4-E-011/V1.1 Page 1 of 8 RF Exposure Evaluation Report Report No.: 2405U81213EG Applicant: Shenzhen Qianyan Technology LTD Address: No.3301, Block C, Section 1, ChuangzhiYuncheng Building, Liuxian Avenue, Xili Community, Xili Street, Nanshan District, Shenzhen, China Product Name: Govee Outdoor Flood Lights 2 Product Model: H7058 Multiple Models: H7057 Trade Mark: Govee FCC ID: 2A7VD-H7057 Standards: 47 CFR §1.1307 KDB 447498 D04 Interim General RF Exposure Guidance v01 Test Date: 2024-06-29 Test Result: Complied Report Date: 2024-07-03 Reviewed by: Approved by: Frank Yin Project Engineer Jacob Kong Manager Prepared by: World Alliance Testing & Certification (Shenzhen) Co., Ltd No. 1002, East Block, Laobing Building, Xingye Road 3012, Xixiang street, Bao'an District, Shenzhen, Guangdong, People’s Republic of China This report may contain data that are not covered by the NVLAP accreditation and shall be marked with an asterisk “★” Report No.: 2405U81213EG Report Template: TR-4-E-011/V1.1 Page 2 of 8 Announcement 1. This test report shall not be reproduced except in full, without the written approval of World Alliance Testing & Certification (Shenzhen) Co., Ltd 2. The results in this report apply only to the sample tested. 3. This sample tested is in compliance with the limits of the above regulation. 4. This report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the U.S. Government. 5. The information marked “#” is provided by the applicant, the laboratory is not responsible for its authenticity and this information can affect the validity of the result in the test report. Customer model name, addresses, names, trademarks etc. are included. Revision History Version No. Issued Date Description 00 2024-07-03 Original Report No.: 2405U81213EG Report Template: TR-4-E-011/V1.1 Page 3 of 8 Contents 1 General Information ............................................................................................................................ 4 1.1 Client Information ...................................................................................................................... 4 1.2 Product Description of EUT ....................................................................................................... 4 1.3 Laboratory Location ................................................................................................................... 5 2 RF Exposure Evaluation ..................................................................................................................... 6 2.1 Standard .................................................................................................................................... 6 2.2 Result......................................................................................................................................... 8 Report No.: 2405U81213EG Report Template: TR-4-E-011/V1.1 Page 4 of 8 1 General Information 1.1 Client Information Applicant: Shenzhen Qianyan Technology LTD Address: No.3301, Block C, Section 1, ChuangzhiYuncheng Building, Liuxian Avenue, Xili Community, Xili Street, Nanshan District, Shenzhen, China Manufacturer: Shenzhen Qianyan Technology LTD Address: No.3301, Block C, Section 1, ChuangzhiYuncheng Building, Liuxian Avenue, Xili Community, Xili Street, Nanshan District, Shenzhen, China 1.2 Product Description of EUT The EUT is Govee Outdoor Flood Lights 2 that contains BLE and 2.4G WLAN radios. Sample Serial Number 2N1P-9 & 2N1P-1 for CE&RE test, 2N1P-11 for RF conducted test (assigned by WATC) Sample Received Date 2024-06-17 Sample Status Good Condition Frequency Range 2.4G WLAN: 2412MHz - 2462MHz BLE: 2402-2480MHz Maximum Conducted Output Power 2.4G WLAN: 22.73dBm BLE: -6.20dBm Modulation Technology 2.4G WLAN : DSSS, OFDM BLE: GFSK Antenna Gain # 2.4G WLAN : 3.98dBi BLE: 3.77dBi Spatial Streams SISO (1TX, 1RX) Power Supply DC 24V from adapter Adapter Information For model H7057: Adapter model: BI48G-240200-AdU Input: AC100-240V, 50/60Hz, 1.4A Output: DC 24V/2.0A For model H7058: Adapter model: SOY-2400300US-306 Input: AC100-240V, 50/60Hz, 1.8A Output: DC 24V/3.0A 72.0W Modification Sample No Modification by the test lab Report No.: 2405U81213EG Report Template: TR-4-E-011/V1.1 Page 5 of 8 1.3 Laboratory Location World Alliance Testing & Certification (Shenzhen) Co., Ltd No. 1002, East Block, Laobing Building, Xingye Road 3012, Xixiang street, Bao'an District, Shenzhen, Guangdong, People’s Republic of China Tel: +86-755-29691511, Email: [email protected] The lab has been recognized as the FCC accredited lab under the KDB 974614 D01 and is listed in the FCC Public Access Link (PAL) database, FCC Registration No. : 463912, the FCC Designation No. : CN5040. The lab has been recognized by Innovation, Science and Economic Development Canada to test to Canadian radio equipment requirements, the CAB identifier: CN0160. Report No.: 2405U81213EG Report Template: TR-4-E-011/V1.1 Page 6 of 8 2 RF Exposure Evaluation 2.1 Standard According to §1.1307(b)(3)(i), For single RF sources (i.e., any single fixed RF source, mobile device, or portable device, as defined in paragraph (b)(2) of this section): A single RF source is exempt if: (A) The available maximum time-averaged power is no more than 1 mW, regardless of separation distance. This exemption may not be used in conjunction with other exemption criteria other than those in paragraph (b)(3)(ii)(A) of this section. Medical implant devices may only use this exemption and that in paragraph (b)(3)(ii)(A); (B) Or the available maximum time-averaged power or effective radiated power (ERP), whichever is greater, is less than or equal to the threshold Pth (mW) described in the following formula. This method shall only be used at separation distances (cm) from 0.5 centimeters to 40 centimeters and at frequencies from 0.3 GHz to 6 GHz (inclusive). Pth is giv…

Text truncated - open the document above for the full version.

Test Report

Report No.: 2405U81213EC Report Template: TR-4-E-008/V1.1 Page 1 of 43 FCC Test Report Report No.: 2405U81213EC Applicant: Shenzhen Qianyan Technology LTD Address: No.3301, Block C, Section 1, ChuangzhiYuncheng Building, Liuxian Avenue, Xili Community, Xili Street, Nanshan District, Shenzhen, China Product Name: Govee Outdoor Flood Lights 2 Product Model: H7058 Multiple Models: H7057 Trade Mark: Govee FCC ID: 2A7VD-H7057 Standards: FCC CFR Title 47 Part 15C (§15.247) Test Date: 2024-06-18 to 2024-09-10 Test Result: Complied Report Date: 2024-09-10 Reviewed by: Approved by: Frank Yin Project Engineer Jacob Kong Manager Prepared by: World Alliance Testing & Certification (Shenzhen) Co., Ltd No. 1002, East Block, Laobing Building, Xingye Road 3012, Xixiang street, Bao'an District, Shenzhen, Guangdong, People’s Republic of China This report may contain data that are not covered by the NVLAP accreditation and shall be marked with an asterisk “★” Report No.: 2405U81213EC Report Template: TR-4-E-008/V1.1 Page 2 of 43 Announcement 1. This test report shall not be reproduced except in full, without the written approval of World Alliance Testing & Certification (Shenzhen) Co., Ltd 2. The results in this report apply only to the sample tested. 3. This sample tested is in compliance with the limits of the above regulation. 4. This report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the U.S. Government. 5. The information marked “#” is provided by the applicant, the laboratory is not responsible for its authenticity and this information can affect the validity of the result in the test report. Customer model name, addresses, names, trademarks etc. are included. Revision History Version No. Issued Date Description 00 2024-09-10 Original Report No.: 2405U81213EC Report Template: TR-4-E-008/V1.1 Page 3 of 43 Contents 1 General Information ............................................................................................................................ 4 1.1 Client Information ...................................................................................................................... 4 1.2 Product Description of EUT ....................................................................................................... 4 1.3 Antenna information .................................................................................................................. 4 1.4 Related Submittal(s)/Grant(s) .................................................................................................... 5 1.5 Measurement Uncertainty ......................................................................................................... 5 1.6 Laboratory Location ................................................................................................................... 5 1.7 Test Methodology ...................................................................................................................... 5 2 Description of Measurement .............................................................................................................. 6 2.1 Test Configuration ...................................................................................................................... 6 2.2 Test Auxiliary Equipment ........................................................................................................... 6 2.3 Interconnecting Cables .............................................................................................................. 6 2.4 Block Diagram of Connection between EUT and AE ................................................................ 7 2.5 Test Setup .................................................................................................................................. 7 2.6 Test Procedure .......................................................................................................................... 9 2.7 Measurement Method.............................................................................................................. 10 2.8 Measurement Equipment ......................................................................................................... 11 3 Test Results ....................................................................................................................................... 12 3.1 Test Summary .......................................................................................................................... 12 3.2 Limit ......................................................................................................................................... 13 3.3 AC Line Conducted Emissions Test Data ................................................................................ 14 3.4 Radiated emission Test Data ................................................................................................... 20 3.5 RF Conducted Test Data ......................................................................................................... 36 3.5.1 6 dB Emission Bandwidth and 99% Occupied Bandwidth ........................................... 36 3.5.2 Maximum Conducted Peak Output Power ................................................................... 36 3.5.3 Power Spectral Density ................................................................................................ 36 3.5.4 100 kHz Bandwidth of Frequency Band Edge ............................................................. 36 3.5.5 Duty Cycle .................................................................................................................... 36 4 Test Setup Photo ............................................................................................................................... 42 5 E.U.T Photo .................................................................................................................…

Text truncated - open the document above for the full version.

Test Report

Report No.: 2405U81213EE Report Template: TR-4-E-009/V1.1 Page 1 of 48 FCC Test Report Report No.: 2405U81213EE Applicant: Shenzhen Qianyan Technology LTD Address: No.3301, Block C, Section 1, ChuangzhiYuncheng Building, Liuxian Avenue, Xili Community, Xili Street, Nanshan District, Shenzhen, China Product Name: Govee Outdoor Flood Lights 2 Product Model: H7058 Multiple Models: H7057 Trade Mark: Govee FCC ID: 2A7VD-H7057 Standards: FCC CFR Title 47 Part 15C (§15.247) Test Date: 2024-06-18 to 2024-06-29 Test Result: Complied Report Date: 2024-07-03 Reviewed by: Approved by: Frank Yin Project Engineer Jacob Kong Manager Prepared by: World Alliance Testing & Certification (Shenzhen) Co., Ltd No. 1002, East Block, Laobing Building, Xingye Road 3012, Xixiang street, Bao'an District, Shenzhen, Guangdong, People’s Republic of China This report may contain data that are not covered by the NVLAP accreditation and shall be marked with an asterisk “★” Report No.: 2405U81213EE Report Template: TR-4-E-009/V1.1 Page 2 of 48 Announcement 1. This test report shall not be reproduced except in full, without the written approval of World Alliance Testing & Certification (Shenzhen) Co., Ltd 2. The results in this report apply only to the sample tested. 3. This sample tested is in compliance with the limits of the above regulation. 4. This report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the U.S. Government. 5. The information marked “#” is provided by the applicant, the laboratory is not responsible for its authenticity and this information can affect the validity of the result in the test report. Customer model name, addresses, names, trademarks etc. are included. Revision History Version No. Issued Date Description 00 2024-07-03 Original Report No.: 2405U81213EE Report Template: TR-4-E-009/V1.1 Page 3 of 48 Contents 1 General Information ............................................................................................................................ 4 1.1 Client Information ...................................................................................................................... 4 1.2 Product Description of EUT ....................................................................................................... 4 1.3 Antenna information .................................................................................................................. 4 1.4 Related Submittal(s)/Grant(s) .................................................................................................... 5 1.5 Measurement Uncertainty ......................................................................................................... 5 1.6 Laboratory Location ................................................................................................................... 5 1.7 Test Methodology ...................................................................................................................... 5 2 Description of Measurement .............................................................................................................. 6 2.1 Test Configuration ...................................................................................................................... 6 2.2 Test Auxiliary Equipment ........................................................................................................... 6 2.3 Interconnecting Cables .............................................................................................................. 7 2.4 Block Diagram of Connection between EUT and AE ................................................................ 7 2.5 Test Setup .................................................................................................................................. 7 2.6 Test Procedure .......................................................................................................................... 9 2.7 Measurement Method.............................................................................................................. 10 2.8 Measurement Equipment ......................................................................................................... 11 3 Test Results ....................................................................................................................................... 12 3.1 Test Summary .......................................................................................................................... 12 3.2 Limit ......................................................................................................................................... 13 3.3 AC Line Conducted Emissions Test Data ................................................................................ 14 3.4 Radiated emission Test Data ................................................................................................... 20 3.5 RF Conducted Test Data ......................................................................................................... 37 3.5.1 6dB Emission Bandwidth and 99% Occupied Bandwidth ............................................ 37 3.5.2 Maximum Conducted Peak Output Power ................................................................... 37 3.5.3 Power Spectral Density ................................................................................................ 38 3.5.4 100 kHz Bandwidth of Frequency Band Edge ............................................................. 38 3.5.5 Duty Cycle .................................................................................................................... 38 4 Test Setup Photo ............................................................................................................................... 47 5 E.U.T Photo .................................................................................................................…

Text truncated - open the document above for the full version.

Test Report

Antenna test report Test Laboratory Dongguan Yijia Electronic Co., LTD Address No. 59 Muyu Road, Shatou Community, Chang 'an Town, Dongguan City, Guangdong Province Contact: Mr. Gan 13823198410 Model H7058 1. Test procedures Name Parameter Method Standard No. Mobile communication antenna VSWR Generic specificaiton for antennas used in the mobile communications GB/T 9410-2008 Antenna Gain Radiation pattern Antenna Radiation efficiency IEEE Standard Test Procedures for Antennas ANSI/IEEE Std 149-1979 2. Test Equipment Equipment Model No. Serial No. Manufacture Calibration Date Next calibration Date 24 probeMicrowave chamber MPS2450 Multi- probeOTAme asurementsystems 5*5*5 YJ-PB-F01XH-IOE 2023.09.01 2024.09.01 NetworkAnalyzer ZVB8 YJ-RD- 15 ROHDE&SCH WARS 2023.08.25 2024.08.25 Widebandradio Communicationtest er CMW500 YJ-RD- 16 ROHDE&SCH WARS 2023.08.25 2024.08.25 3 . 4. 5 . . DUT Set . Bluetoot . WIFI An tup Photo th Antenna ntenna Phy a Physical ysical Size l Size e 6. B T W . Bluetoot Type:PCB Freq T: WiFi: th&WiFi uency / MHz 2400 2410 2420 2430 2440 2450 2460 2470 2480 2490 2500 Antenna T z Type & Ga BT Gain 3.77 3.59 3.3 3.29 3.41 3.51 3.54 3.47 3.34 3.44 2.93 ain n/ dBi 7 9 3 9 1 1 4 7 4 4 3 WiFi Gain/ 3.98 3.85 3.46 3.03 2.5 2.63 2.83 3.03 3.17 3.11 2.97 dBi 7. Bluetooth Antenna Pattern Picture 2400MHz 2450MHz 2500MHz 8. WiFi Antenna Pattern Picture 2400MHz 2450MHz 2500MHz Tester by:Wu xianming

Contact Information

Applicant

Xiaopeng Pan
[email protected]+86-13632599550Fax: 0755-23739351

Test Firm

World Alliance Testing & Certification (Shenzhen)Stefani Hu
[email protected]0755-29691511

Technical Specifications

#Rule PartsFrequency RangePower Output
215C2.41 GHz - 2.46 GHz187.50 mW
Confidentiality
Long Term
Grant Notes
Output power listed is peak conducted. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. Users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance.

Other Applications from Shenzhen Qianyan Technology LTD

2A7VD-H1771

Govee Wallwash Table Lamp

Aug 13, 2026

Equipment Class

DTS - Digital Transmission System
2A7VD-H7078A

Govee Smart Outdoor Wall Light

Aug 13, 2026

Equipment Class

DTS - Digital Transmission System
2A7VD-H6842

Govee Cone Tree Lights

Aug 13, 2026

Equipment Class

DTS - Digital Transmission System
2A7VD-H70B3

Govee Curtain Lights 2

Aug 06, 2026

Equipment Class

DTS - Digital Transmission System
2A7VD-H5058A

Water Leak Detector 2

Aug 06, 2026

Equipment Class

DTS - Digital Transmission System