2A7ZZ-DBH-04Thermal Imaging Scope

Visir Inc.
Thermal Imaging Scope - FCC ID 2A7ZZ-DBH-04 - Visir Inc.
Click to zoom

Application Details

Equipment Class
DSS - Part 15 Spread Spectrum Transmitter
Date of Grant
Dec 16, 2025
Application Purpose
Original Equipment
Equipment Note
Thermal Imaging Scope
Frequency Range
2402.00000000 - 2480.00000000
Company
Visir Inc.
Country
United States

Documents & Files

Select a file to view

Attestation Statements

↗
↗

Cover Letter(s)

↗
↗

External Photos

↗
↗

ID Label/Location Info

↗

RF Exposure Info

↗

Test Report

↗
↗
↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Attestation Statements

Rev 1/26/2023 Visir Inc. 700 InternationalPkwySte 102 , Richardson, Texas75081, UnitedStates FederalCommunicationsCommission Authorizationand EvaluationDivision 7435OaklandMillsRoad Columbia,MD 21046 USA Date:11 -26 -2025 Ref:AttestationStatementsPart 2.911(d)(5)(i)Filing FCC ID: 2A7ZZ-DBH-04 [VisirInc.] (“the applicant”) certifiesthat the equipmentfor whichauthorizationis soughtis not “covered” equipmentprohibitedfromreceivingan equipmentauthorizationpursuantto section2.903of the FCC rules. [VisirInc.] (“the applicant”) certifiesthat the equipmentfor whichauthorizationis soughtdoesnot includecybersecurityor anti-virussoftwareproducedor providedby KasperskyLab, Inc. or any of its successorsand assignees,includingequipmentwith integratedKasperskyLab, Inc. (or any of its successorsand assignees)cybersecurityor anti-virussoftwarepursuantto DA-24-886and KDB 986446 D01 CoveredEquipmentGuidancesectionB(2a). Deviceis inherentlycompliantbasedon hardwarelimitationsor softwarecontrols. or A SoftwareBill of Materials(SBOM)is providedto the TCB for review,and The end-useror thirdpartiescannotinstalladditionalsoftwareon this device. Sincerely, (Applicantsignature) Tao , Huang Rev1/26/2023 VisirInc. 700InternationalPkwySte102,Richardson,Texas75081,UnitedStates FederalCommunicationsCommission AuthorizationandEvaluationDivision 7435OaklandMillsRoad Columbia,MD21046 USA Date:11-26-2025 Ref:AttestationStatementsPart2.911(d)(5)(ii)Filing FCCID:2A7ZZ-DBH-04 [VisirInc.](“theapplicant”)certifiesthat,asofthedateofthefilingoftheapplication,theapplicantis notidentifiedontheCoveredList(asaspecificallynamedentityoranyofitssubsidiariesoraffiliates)as anentityproducing“covered”equipment. Sincerely, (Applicantsignature) Tao,Huang

Attestation Statements

Rev 1/26/2023 Visir Inc. 700 InternationalPkwySte 102 , Richardson, Texas75081, UnitedStates FederalCommunicationsCommission Authorizationand EvaluationDivision 7435OaklandMillsRoad Columbia,MD 21046 USA Date:11 -26 -2025 Ref:AttestationStatementsPart 2.911(d)(7)Filing FCC ID: 2A7ZZ-DBH-04 ApplicantFRN:0032684243 [VisirInc.] (“the applicant”) certifiesthat,as of the dateof the filingof the application,[VisirInc.] is our designatedU.S. agentfor serviceof processfor the abovereferencedFCC ID. [VisirInc.] acceptsto maintainan agentfor no less thanone year afterthe granteehas terminatedall marketingand importationor the conclusionof any Commission-relatedproceedinginvolvingthe equipment. [VisirInc.] accepts,as of the dateof the filingof the application,the obligationof the designatedU.S. agentfor serviceof processfor the abovereferencedFCC ID. DesignatedU.S. AgentInformation: Name:Visir Inc. U.S. AgentFRN:0032684243 Address:700 InternationalPkwySte 102 , Richardson, Texas75081, UnitedStates ContactPerson:Tao, Huang Tel.: 5109885580-500 Email:[email protected] Sincerely, Visir Inc.Visir Inc. Tao, HuangTao, Huang [InsertApplicantsignature][InsertApplicantsignature]

Cover Letter(s)

Rev 11/20/07 Visir Inc. 700 InternationalPkwySte 102 , Richardson, Texas75081, UnitedStates FederalCommunicationsCommission Authorizationand EvaluationDivision ConfidentialityRequestregardingapplicationfor certificationof FCC ID: 2A7ZZ-DBH-04 Pursuantto Sections0.457 and 0.459 of the Commission’s Rules, we herebyrequestconfidential treatmentof informationaccompanyingthis applicationas outlinedbelow: Exhibit TypeFile Name Block Diagram Schematics Operational Description PCB BOMBOM Block Diagram Schematics Operational Description PCB The above materialscontaintrade secretsand proprietaryinformationnot customarilyreleasedto the public.The public disclosureof these materialsmay be harmfulto the applicantand provide unjustifiedbenefitsto its competitors. The applicantunderstandsthat pursuantto Section0.457 of the Rules, disclosureof this applicationand all accompanyingdocumentationwill not be made before the date of the Grant for this application. Pursuantto DA04-1705June 15, 2004 of the Commission’s public notice,we also request temporaryconfidentialtreatmentof informationaccompanyingthis applicationas outlinedbelow: ExhibitTypeFile Name InternalPhotos Setup photos Manual InternalPhotos Setup photos Manual Numberof days: 180 days Sincerely, (Applicant signature) Tao, Huang 2025/12/12

Cover Letter(s)

Visir Inc. 700 InternationalPkwySte 102 , Richardson, Texas75081, UnitedStates FederalCommunicationsCommission AuthorizationandEvaluationDivision 1435OaklandMillsRoad Columbia,MD21046 Date:11/26/2025 SUBJECT:FCCApplicationforFCCID:2A7ZZ-DBH-04 ToWhomIt MayConcern: We,theundersigned,herebyauthorizeHongYanat TÜV SÜD CertificationandTesting (China)Co.,Ltd.ShanghaiBranchon ourbehalf,to applyto theFederalCommunications Commissionon ourequipment.Anyandall actscarriedoutby HongYanon ourbehalf shallhavethesameeffectas actsof ourown. Thisis to advisethatwearein fullcompliancewiththeAnti-DrugAbuseAct.We,the applicant,arenotsubjectto a denialof federalbenefitspursuantto Section5301of the Anti-DrugActof 1988,21 USC853a,andno partyto theapplicationis subjectto a denial of federalbenefitspursuantto thatsection. Regards, (Applicantsignature) Tao, Huang

External Photos

EUT Appearance Report No.: EFTA25090409-IE-01 Eurofins TA Technology (Shanghai) Co., Ltd. TA-MB-01-032E Page 1 of 3 This report shall not be reproduced except in full, without the written approval of Eurofins TA Technology (Shanghai) Co., Ltd. EUT Appearance EUT Appearance Report No.: EFTA25090409-IE-01 Eurofins TA Technology (Shanghai) Co., Ltd. TA-MB-01-032E Page 2 of 3 This report shall not be reproduced except in full, without the written approval of Eurofins TA Technology (Shanghai) Co., Ltd. EUT Appearance Report No.: EFTA25090409-IE-01 Eurofins TA Technology (Shanghai) Co., Ltd. TA-MB-01-032E Page 3 of 3 This report shall not be reproduced except in full, without the written approval of Eurofins TA Technology (Shanghai) Co., Ltd.

External Photos

External Photos Documentation Manufacturer: Visir Inc. Page 1 of 3 Product: Thermal Imaging Scope FCC ID: 2A7ZZ-DBH-04 Model: DBH D12 External Photos Documentation Manufacturer: Visir Inc. Page 2 of 3 Product: Thermal Imaging Scope FCC ID: 2A7ZZ-DBH-04 Model: DBH D12 External Photos Documentation Manufacturer: Visir Inc. Page 3 of 3 Product: Thermal Imaging Scope FCC ID: 2A7ZZ-DBH-04 Model: DBH D12

RF Exposure Info

Prepared by: Wei Fangying Approved by: Xu Kai Eurofins TA Technology (Shanghai) Co., Ltd. Building 3, No.145, Jintang Rd, Pudong Shanghai, P.R.China TEL: +86-021-50791141/2/3 FAX: +86-021-50791141/2/3-8000 SAR TEST REPORT Applicant Visir Inc. FCC ID 2A7ZZ-DBH-04 Product Thermal Imaging Scope Brand RIX Model DBH D12 Report No. EFTA25090409-IE-01-S1 Issue Date November 25, 2025 Eurofins TA Technology (Shanghai) Co., Ltd. tested the above equipment in accordance with the requirements in IEEE 1528-2013, ANSI C95.1: 1992, IEEE C95.1: 1991. The test results show that the equipment tested can demonstrate compliance with the requirements as documented in this report. SAR Test Report Report No.: EFTA25090409-IE-01-S1 Eurofins TA Technology (Shanghai) Co., Ltd. TA-MB-06-003S Page 2 of 65 This report shall not be reproduced except in full, without the written approval of Eurofins TA Technology (Shanghai) Co., Ltd. Table of Contents 1 Test Laboratory ................................................................................................................................. 3 1.1 Notes of the Test Report ............................................................................................................ 3 1.2 Test Facility ................................................................................................................................ 3 1.3 Testing Location......................................................................................................................... 3 1.4 Laboratory Environment ............................................................................................................ 3 2 Statement of Compliance .................................................................................................................. 4 3 Description of Equipment Under Test ............................................................................................... 5 4 Test Specification, Methods and Procedures ................................................................................... 7 5 Operational Conditions during Test ................................................................................................... 8 5.1 Test Positions ............................................................................................................................ 8 5.1.1 Extremity exposure conditions ......................................................................................... 8 5.2 Measurement Variability ............................................................................................................ 9 5.3 Test Configuration ................................................................................................................... 10 5.3.1 Wi-Fi Test Configuration ................................................................................................. 10 5.3.2 Bluetooth Test Configuration .......................................................................................... 11 6 SAR Measurements System Configuration .................................................................................... 12 6.1 SAR Measurement Set-up ....................................................................................................... 12 6.2 DASY5 E-field Probe System .................................................................................................. 13 6.3 SAR Measurement Procedure ................................................................................................. 14 7 Main Test Equipment ....................................................................................................................... 16 8 Tissue Dielectric Parameter Measurements & System Check ....................................................... 17 8.1 Tissue Verification ................................................................................................................... 17 8.2 System Check .......................................................................................................................... 19 8.3 SAR System Validation ............................................................................................................ 22 9 Normal and Maximum Output Power .............................................................................................. 23 9.1 WLAN Mode ............................................................................................................................. 23 9.2 Bluetooth Mode ........................................................................................................................ 24 10 Measured and Reported (Scaled) SAR Results ............................................................................. 25 10.1 EUT Antenna Locations ........................................................................................................... 25 10.2 Standalone SAR Test Exclusion Considerations .................................................................... 26 10.3 Measured SAR Results ........................................................................................................... 27 11 Measurement Uncertainty ............................................................................................................... 28 ANNEX A: Test Layout ........................................................................................................................... 29 ANNEX B: System Check Results ......................................................................................................... 31 ANNEX C: Highest Graph Results ......................................................................................................... 32 ANNEX D: Probe Calibration Certificate (SN: 3677) ............................................................................. 33 ANNEX E: D2450V2 Dipole Calibration Certificate .............................................................................…

Text truncated - open the document above for the full version.

Test Report

Report Number: 709502507814-00D EMC_SHA_F_R_02.03E TÜV SÜD Certification and Testing (China) Co., Ltd. Shanghai Branch 3-13, No.151, Heng Tong Road, Shanghai, 200070, P.R. China Phone: +86 21 61410123, Fax:+86 21 61408600 Page 1 of 96 Rev. 23.00 FCC - TEST REPORT Report Number : 709502507814-00D Date of Issue: October 9, 2025 Model : DBH D12 Product Type : Thermal Imaging Scope Applicant : Visir Inc. Address : 700 International Pkwy, Ste 102, Richardson, TX 75081, United States Production Facility : Visir Inc. Address : 700 International Pkwy, Ste 102, Richardson, TX 75081, United States Test Result : ◼ Positive  Negative Total pages including Appendices : 96 TÜV SÜD Certification and Testing (China) Co., Ltd. Shanghai Branch is a subcontractor to TÜV SÜD Product Service GmbH according to the principles outlined in ISO 17025. TÜV SÜD Certification and Testing (China) Co., Ltd. Shanghai Branch reports apply only to the specific samples tested under stated test conditions. Construction of the actual test samples has been documented. It is the manufacturer's responsibility to assure that additional production units of this model are manufactured with identical electrical and mechanical components. The manufacturer/importer is responsible to the Competent Authorities in Europe for any modifications made to the production units which result in non-compliance to the relevant regulations. TÜV SÜD Certification and Testing (China) Co., Ltd. Shanghai Branch shall have no liability for any deductions, inferences or generalizations drawn by the client or others from TÜV SÜD Certification and Testing (China) Co., Ltd. Shanghai Branch issued reports. This report is the confidential property of the client. As a mutual protection to our clients, the public and ourselves, extracts from the test report shall not be reproduced except in full without our written approval. Report Number: 709502507814-00D EMC_SHA_F_R_02.03E TÜV SÜD Certification and Testing (China) Co., Ltd. Shanghai Branch 3-13, No.151, Heng Tong Road, Shanghai, 200070, P.R. China Phone: +86 21 61410123, Fax:+86 21 61408600 Page 2 of 96 Rev. 23.00 1 Table of Contents 1 Table of Contents .................................................................................................................. 2 2 Report Modification Record .................................................................................................. 3 3 Details about the Test Laboratory ......................................................................................... 3 4 Description of the Equipment Under Test ............................................................................. 4 5 Summary of Test Standards ................................................................................................. 7 6 Summary of Test Results ...................................................................................................... 8 7 General Remarks ................................................................................................................. 9 8 Test Setups ......................................................................................................................... 10 9 Systems test configuration .................................................................................................. 13 10 Technical Requirement ....................................................................................................... 14 10.1 Conducted peak(average) output power ..................................................................... 14 10.2 20 dB bandwidth and 99% Occupied Bandwidth ......................................................... 26 10.3 Carrier Frequency Separation ..................................................................................... 34 10.4 Number of hopping frequencies .................................................................................. 37 10.5 Dwell Time ................................................................................................................... 39 10.6 Spurious RF conducted emissions .............................................................................. 44 10.7 Band edge testing........................................................................................................ 51 10.8 Spurious radiated emissions for transmitter ................................................................ 64 11 Test Equipment List ............................................................................................................ 93 12 System Measurement Uncertainty ...................................................................................... 94 13 Photographs of Test Set-ups .............................................................................................. 95 14 Photographs of EUT ........................................................................................................... 96 Report Number: 709502507814-00D EMC_SHA_F_R_02.03E TÜV SÜD Certification and Testing (China) Co., Ltd. Shanghai Branch 3-13, No.151, Heng Tong Road, Shanghai, 200070, P.R. China Phone: +86 21 61410123, Fax:+86 21 61408600 Page 3 of 96 Rev. 23.00 2 Report Modification Record Alterations and additions to this report will be issued to the holders of each copy in the form of a complete document. Issue Description of Change Date of Issue 709502507814-00D First Issue 10/09/2025 3 Details about the Test Laboratory Details about the Test Laboratory Test Site 1 Company name: TÜV SÜD Certification and Testing (China) Co., Ltd. Shanghai Branch No.16 Lane, 1951 Du Hui Road, Shanghai 201108, P.R. China Telephone: +86 21 6141 0123 Fax: +86 21 6140 8600 FCC Registration No.: 820234 FCC Designation Number: CN1183 ISED CAB identifier CN0101 IC Registration No.: 31668 Report Number: 709502507814-00D EMC_SHA_F_R_02.03E TÜV SÜD Certification and Testing (China) Co., Ltd. Shanghai Branch 3-13, No.151, Heng Tong Road, Shanghai, 200070, P.R. China Phon…

Text truncated - open the document above for the full version.

Test Report

Report Number: 709502507814-00D EMC_SHA_F_R_02.03E TÜV SÜD Certification and Testing (China) Co., Ltd. Shanghai Branch 3-13, No.151, Heng Tong Road, Shanghai, 200070, P.R. China Phone: +86 21 61410123, Fax:+86 21 61408600 Page 35 of 96 Rev. 23.00 Carrier Frequency Separation Test result: The measurement was performed with the typical configuration (normal hopping status), here GFSK, π/4-DQPSK and 8DPSK modulation mode (low channel) was used to show compliance. GFSK Modulation test result Modulation Frequency Carrier Frequency Separation Result MHz MHz GFSK 2441 1.002 Pass π/4-DQPSK 2441 1.002 Pass 8DPSK 2441 0.998 Pass Report Number: 709502507814-00D EMC_SHA_F_R_02.03E TÜV SÜD Certification and Testing (China) Co., Ltd. Shanghai Branch 3-13, No.151, Heng Tong Road, Shanghai, 200070, P.R. China Phone: +86 21 61410123, Fax:+86 21 61408600 Page 36 of 96 Rev. 23.00 Test Graphs CFS NVNT 1-DH5 2441MHz Ant1 CFS NVNT 2-DH5 2441MHz Ant1 CFS NVNT 3-DH5 2441MHz Ant1 Report Number: 709502507814-00D EMC_SHA_F_R_02.03E TÜV SÜD Certification and Testing (China) Co., Ltd. Shanghai Branch 3-13, No.151, Heng Tong Road, Shanghai, 200070, P.R. China Phone: +86 21 61410123, Fax:+86 21 61408600 Page 37 of 96 Rev. 23.00 10.4 Number of hopping frequencies Test Method 1. The RF output of EUT was connected to the spectrum analyzer by RF cable. The path loss was compensated to the results for each measurement. 2. Set to the maximum power setting and enable the EUT transmit to hopping mode. 3. Use the following spectrum analyzer settings: Span = the frequency band of operation, RBW: To identify clearly the individual channels, set the RBW to less than 30% of the channel spacing or the 20 dB bandwidth, whichever is smaller, VBW ≥RBW, Sweep = auto, Detector function = peak, Trace=Max hold. 4. Allow the trace to stabilize. It may prove necessary to break the span up to sections, in order to clearly show all of the hopping frequencies. The limit is specified in one of the subparagraphs of this Section. Submit this plot(s). Limit Limit number ≥ 15 Report Number: 709502507814-00D EMC_SHA_F_R_02.03E TÜV SÜD Certification and Testing (China) Co., Ltd. Shanghai Branch 3-13, No.151, Heng Tong Road, Shanghai, 200070, P.R. China Phone: +86 21 61410123, Fax:+86 21 61408600 Page 38 of 96 Rev. 23.00 Number of hopping frequencies Test result: The measurement was performed with the typical configuration (normal hopping status), and the total hopping channels is constant for the all modulation mode according with the Bluetooth Core Specification. Here GFSK modulation mode was used to show compliance. Number of hopping frequencies Result 79 Pass Test Graphs Hopping No. NVNT 1-DH5 2402MHz Ant1 Report Number: 709502507814-00D EMC_SHA_F_R_02.03E TÜV SÜD Certification and Testing (China) Co., Ltd. Shanghai Branch 3-13, No.151, Heng Tong Road, Shanghai, 200070, P.R. China Phone: +86 21 61410123, Fax:+86 21 61408600 Page 39 of 96 Rev. 23.00 10.5 Dwell Time Test Method 1. The RF output of EUT was connected to the spectrum analyzer by RF cable. The path loss was compensated to the results for each measurement. 2. Set to the maximum power setting and enable the EUT transmit to hopping mode. 3. Span: Zero span, centered on a hopping channel. 4. RBW shall be ≤ channel spacing and where possible RBW should be set >> 1 / T, where T is the expected dwell time per channel. 5. Sweep: As necessary to capture the entire dwell time per hopping channel; where possible use a video trigger and trigger delay so that the transmitted signal starts a little to the right of the start of the plot. The trigger level might need slight adjustment to prevent triggering when the system hops on an adjacent channel; a second plot might be needed with a longer sweep time to show two successive hops on a channel. 6. Detector function: Peak. 7. Trace: Max hold. Use the marker-delta function to determine the transmit time per hop. If this value varies with different modes of operation (data rate, modulation format, number of hopping channels, etc.), then repeat this test for each variation in transmit time. Limit The average time of occupancy on any frequency shall not be greater than 0.4 seconds within a period of 0.4 seconds multiplied by the number of hopping channels employed. Report Number: 709502507814-00D EMC_SHA_F_R_02.03E TÜV SÜD Certification and Testing (China) Co., Ltd. Shanghai Branch 3-13, No.151, Heng Tong Road, Shanghai, 200070, P.R. China Phone: +86 21 61410123, Fax:+86 21 61408600 Page 40 of 96 Rev. 23.00 Dwell Time Dwell time The maximum dwell time shall be 0,4 s. According to the Bluetooth Core Specification, the worse result (DH5 mode) was reported to show compliance. The Dwell Time = Burst Width * Total Hops. The detailed calculations are showed as follows: The duration for dwell time calculation: 0.4 [s] * hopping number = 0.4 [s] * 79 [ch] = 31.6 [s*ch]; The burst width, which is directly measured, refers to the duration on one channel hop. Test Result Modulation Mode Reading (ms) Total Hops Test Result (ms) Limit (ms) Result GFSK DH5 2.888 101 291.688 < 400 Pass π/4-DQPSK 2DH5 2.89 109 315.01 < 400 Pass 8-DPSK 3DH5 2.892 106 306.552 < 400 Pass Report Number: 709502507814-00D EMC_SHA_F_R_02.03E TÜV SÜD Certification and Testing (China) Co., Ltd. Shanghai Branch 3-13, No.151, Heng Tong Road, Shanghai, 200070, P.R. China Phone: +86 21 61410123, Fax:+86 21 61408600 Page 41 of 96 Rev. 23.00 GFSK Modulation Test Graphs Dwell NVNT 1-DH5 2402MHz Ant1 One Burst Dwell NVNT 1-DH5 2402MHz Ant1 Accumulated Report Number: 709502507814-00D EMC_SHA_F_R_02.03E TÜV SÜD Certification and Testing (China) Co., Ltd. Shanghai Branch 3-13, No.151, Heng Tong Road, Shanghai, 200070, P.R. China Phone: +86 21 61410123, Fax:+86 21 61408600 Page 42 of 96 Rev. 23.00 π/4-DQPSK Modulation Dwell NVNT 2-DH5 2402MHz Ant1 One Burst Dwell NVNT 2-DH5 2402MHz Ant1 Accumulated Report Number: 709502507814-00D EMC_SHA_F_R_02.03E TÜV SÜD Certification and Testing (China) Co., Ltd. Shanghai …

Text truncated - open the document above for the full version.

Test Report

ShenzhenHuakeCommunicationsCo.,Ltd. 网站:www.huake-china.comNinefloor,Yonghebuilding,23YongheRoad,BaoanDistrict,Shenzhen,Guangdong,China 5180001/12 目录 1、Picture ............................................................................................................................................................ 3 2、Partspecification ........................................................................................................................................... 3 3、Pharacteristicparameter .............................................................................................................................. 4 4、Drawing .......................................................................................................................................................... 5 5、Circuitmatching ................................................................................................................................................. 6 6、VSWRexperiment ......................................................................................................................................... 7 6.1、VSWR ................................................................................................................................................................ 7 6.2、Darkroomtestdata ........................................................................................................................................ 8 7、Environmentaltestexperiment ................................................................................................................. 12 7.1、Saltspraytestexperiment ......................................................................................................................... 12 7.2、Highandlowtemperature ......................................................................................................................... 13 versionformulateRevisedcontentReasonforrevisiondate V1.0 Liubinadd 20230708 V1.1 LiubinperformanceoptimizationWholemachinematching 20230715 V1.2 LiubinChangetheoutletdirection 20230814 ShenzhenHuakeCommunicationsCo.,Ltd. 网站:www.huake-china.comNinefloor,Yonghebuilding,23YongheRoad,BaoanDistrict,Shenzhen,Guangdong,China 5180002/12 1、Productpicture 2、Maincomponentsandcomposition Productname:WiFiantennaModelPartno:HC-ANT-AR24510022 1 ConnectorType IPEX 2 ConnectorCoatingGild 3 CableType0.81 6 Technology 7 RadiatingElementFPCSoftboard 8 CoatingBlackplating 3、Characteristicparameter ShenzhenHuakeCommunicationsCo.,Ltd. 网站:www.huake-china.comNinefloor,Yonghebuilding,23YongheRoad,BaoanDistrict,Shenzhen,Guangdong,China 5180003/12 FrenquencyRang2400-2500MHz Impedance50Ω RadiationOmnidirection PolarizationPerpendicular CoatingBlackplating Height29.4*25.3mm CableLength100mm workingTemperature -45-+85°C StorageTemperature -45-+85°C ApplicableBand WiFi Humidity <95% Installationmode Pasteandsnap ShenzhenHuakeCommunicationsCo.,Ltd. 网站:www.huake-china.comNinefloor,Yonghebuilding,23YongheRoad,BaoanDistrict,Shenzhen,Guangdong,China 5180004/12 4、Sizestructurediagram ShenzhenHuakeCommunicationsCo.,Ltd. 网站:www.huake-china.comNinefloor,Yonghebuilding,23YongheRoad,BaoanDistrict,Shenzhen,Guangdong,China 5180005/12 5、Circuitmatching Nomatchingwasaddedtotheclientboard end. ShenzhenHuakeCommunicationsCo.,Ltd. 网站:www.huake-china.comNinefloor,Yonghebuilding,23YongheRoad,BaoanDistrict,Shenzhen,Guangdong,China 5180006/12 6、Electricalperformancetestchart 6.1,Standingwavetestchart Fill: 1.Theantennaandprototypearematched,debuggedandverified. 1,2.Fortheinstallationlocationanddetailedtestreport,seetheadjustmentreportRAKIantennacompletemachinematchingadjustment report20230708. ShenzhenHuakeCommunicationsCo.,Ltd. 网站:www.huake-china.comNinefloor,Yonghebuilding,23YongheRoad,BaoanDistrict,Shenzhen,Guangdong,China 5180007/12 6.2,Darkroomtestdata Efficiency&gain(2.4WiFi2400-2500MHz) Freqency(MHz)Gain(dbi)Efficiency(db)Efficiency(%) 24000.09-5.1230.74 24100.35-4.9931.69 24200.32-5.0731.15 24300.46-5.0131.58 24400.62-4.9531.96 24500.83-5.0131.58 24600.69-5.1930.28 24700.56-5.2429.94 24800.59-5.1230.75 24900.16-5.4428.58 25000.26-5.2729.71 ShenzhenHuakeCommunicationsCo.,Ltd. 网站:www.huake-china.comNinefloor,Yonghebuilding,23YongheRoad,BaoanDistrict,Shenzhen,Guangdong,China 5180008/12 directionaldiagram2400MHz ShenzhenHuakeCommunicationsCo.,Ltd. 网站:www.huake-china.comNinefloor,Yonghebuilding,23YongheRoad,BaoanDistrict,Shenzhen,Guangdong,China 5180009/12 directionaldiagram2450MHz ShenzhenHuakeCommunicationsCo.,Ltd. 网站:www.huake-china.comNinefloor,Yonghebuilding,23YongheRoad,BaoanDistrict,Shenzhen,Guangdong,China 51800010/12 directionaldiagram2500MHz ShenzhenHuakeCommunicationsCo.,Ltd. 网站:www.huake-china.comNinefloor,Yonghebuilding,23YongheRoad,BaoanDistrict,Shenzhen,Guangdong,China 51800011/12 7、Environmentalreliabilitytest 7.1、Saltspraytest Saltspraytestreport Testingpart: QCTesters:YuFeiDate:2023.07.08 Nameoftestsample: Connector Type: HC-ANTAR-24510022(IPEX) Number:3PCS Testitem:SaltspraytestDevicename:Saltspraycorrosiontestchamber testmethod: Thetestsampleswereputintothemodulatedsaltsolutiontestchamberandsalt spraycorrosionchamberforcontinuousspraytest. Concentrationofsalt solution: 52g/LPH:6.7 Testcycle:50h Teststandard: ThetestshallbecarriedoutinaccordancewithGB/t10125corrosiontestin artificialatmosphereandsaltspraytest;theresultsshallberatedin accordancewithGB/t6461-2002corrosiontestofmetalandotherinorganic coatingsonmetalsubstrateandtheratingoftestpiecesandtestpieces Result NOGradeResultRemarks 1Rp/Ra=10/10vsBOK 2Rp/Ra=10/10vsBOK 3Rp/Ra=10/10vsBOK ShenzhenHuakeCommunicationsCo.,Ltd. 网站:www.huake-china.comNinefloor,Yonghebuilding,23YongheRoad,BaoanDistrict,Shenzhen,Guangdong,China 51800012/12 7.2Highandlowtemperaturetest EnvironmentalPerformance TestDescript…

Text truncated - open the document above for the full version.

Contact Information

Applicant

Tao Huang
[email protected]Fax: 5555555555

Technical Contact

Visir Inc.Tao Huang
[email protected]

700 International Pkwy Ste 102 · Richardson, Texas, 75081 · United States

Test Firm

TUV SUD Certification and Testing (China) Co., LtdYi Ba
[email protected]

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.40 GHz - 2.48 GHz1.81 mW
Confidentiality
Long Term
Grant Notes
Output Power listed is the maximum conducted output power. This device must not be co-located or operating in conjunction with any other antenna or transmitter, except in accordance with FCC multi-transmitter product procedures, or as evaluated in this filing. Meets SAR exclusion .

Other Applications from Visir Inc.

RIX Remote Control - FCC ID 2A7ZZ-NN00-01 - Visir Inc.
2A7ZZ-NN00-01

RIX Remote Control

Jul 13, 2026

Equipment Class

DTS - Digital Transmission System
THERMAL IMAGING SCOPE - FCC ID 2A7ZZ-GT00-04 - Visir Inc.
2A7ZZ-GT00-04

THERMAL IMAGING SCOPE

Jun 10, 2026

Equipment Class

DTS - Digital Transmission System
THERMAL IMAGING ATTACHMENT - FCC ID 2A7ZZ-NN00-00 - Visir Inc.
2A7ZZ-NN00-00

THERMAL IMAGING ATTACHMENT

Jun 04, 2026

Equipment Class

DTS - Digital Transmission System
THERMAL IMAGING MONOCULAR - FCC ID 2A7ZZ-STRD-00 - Visir Inc.
2A7ZZ-STRD-00

THERMAL IMAGING MONOCULAR

Apr 23, 2026

Equipment Class

DTS - Digital Transmission System
Thermal Imager - FCC ID 2A7ZZ-RENV-C - Visir Inc.
2A7ZZ-RENV-C

Thermal Imager

Jun 29, 2025

Equipment Class

DTS - Digital Transmission System