Application Details

Equipment Class
8CC - Part 18 Consumer Device
Date of Grant
Nov 10, 2022
Application Purpose
Original Equipment
Date of Application
Nov 10, 2022
Equipment Note
WIRELESS CHARDING POWER BANK
Frequency Range
0.11000000 - 0.20500000
Company
ShenZhen South Fortune Technology Co.,Ltd
Country
China

Documents & Files

Select a file to view

Users Manual

↗

Cover Letter(s)

↗
↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

CameraGPS Connected band/watch MP3/MP4Mobile phoneTablet 2 1 3 7 4 5 6 8 9 FCC Statement This device complies with part 18 of the FCC Rules. Operation is Subject To the following two conditions: (1) This device may not cause harmful interference, and (2) this devicemust accept any interference received, including interference that may cause undesired operation. Changes or modifications not explicitly approved by the partyresponsible for compliance could void the user's authority tooperate this equipment. Note: this equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 18 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and canradiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference toradio or television reception, which can be determined by turning the equipment off and on, the user is encouraged totry to correct the interference by one or more of the following measures: • Reorient or relocate the receiving antenna. • Increase the separation between the equipment and receiver. • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. • Consult the dealer or an experienced radio/TV technician for help. The equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. During the operation of device a distance of 15 cm surrounding the device and 20 cm above the top surface of the device must be respected. This device complies with Part 18 of the FCC Rules. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: ●Increase the separation between the equipment and any other radio device. ●Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.

Cover Letter(s)

Shen Zhen South Fortune Technology Co., Ltd. Agent Authorization Company: Shen Zhen South Fortune Technology Co., Ltd. Address: 4th Floor, Building C, Ganghua High-tech park, Nanwan Street, Buji Town, Longgang District, Shenzhen, China Product Name: WIRELESS CHARDING POWER BANK Trade Mark: Heloideo, PneuATP, TWINTECH Model Number(s): PB147ACW, PB147W, HIT#2896BLK, HIT#2896WHT, #2756Chi- Charge Plus We authorize MiCOM Labs Inc., 575 Boulder Court, Pleasanton, California 94566, USA, to act on our behalf on all matters concerning the certification of above named equipment. We declare that MiCOM Labs Inc. is allowed to forward all information related to the approval and certification of equipment to the regulatory agencies as required and to discuss any issues concerning the approval application. Any and all acts carried out by MiCOM Labs on our behalf shall have the same effect as acts of our own. Date: 2022-10-26 Signature: Name: Sandy Zhang Company: Shen Zhen South Fortune Technology Co., Ltd.

External Photos

FCC ID:2A825-PB147ACW TB-RF-074-1.0 Appendix II EUT External Photographs Photo 1 Appearance of EUT Photo 2 Appearance of EUT FCC ID:2A825-PB147ACW TB-RF-074-1.0 Photo 3 Appearance of EUT Photo 4 Appearance of EUT FCC ID:2A825-PB147ACW TB-RF-074-1.0 Photo 5 Appearance of EUT Photo 6 Appearance of EUT

ID Label/Location Info

FCC ID:2A825-PB147ACW TB-RF-074-1.0 Appendix IFCC ID Label FCC ID: 2A825-PB147ACW

Internal Photos

FCC ID:2A825-PB147ACW TB-RF-074-1.0 Appendix III EUT Internal Photographs Photo 7 Internal of EUT Photo 8 Battery Parameters FCC ID:2A825-PB147ACW TB-RF-074-1.0 Photo 9 Internal of EUT Photo 10 Appearance of PCB FCC ID:2A825-PB147ACW TB-RF-074-1.0 Photo 11 Appearance of PCB Photo 12 Appearance of PCB Coil Antenna

RF Exposure Info

Shenzhen Toby Technology Co., Ltd. Report No.: TBR-C-202210-0059-2 Page: 1 of 29 TB-RF-075-1.0 1/F.,Building 6, Rundongsheng Industrial Zone, Longzhu, Xixiang, Bao'an District, Shenzhen, Guangdong, China Tel: +86 75526509301 Fax: +86 75526509195 RF Exposure Evaluation FCC ID: 2A825-PB147ACW 1. Client Information Applicant : Shen Zhen South Fortune Technology Co., Ltd. Address : 4th Floor, Building C, Ganghua High-tech park, Nanwan Street, Buji Town, Longgang District, Shenzhen, China Manufacturer : Shen Zhen South Fortune Technology Co., Ltd. Address : 4th Floor, Building C, Ganghua High-tech park, Nanwan Street, Buji Town, Longgang District, Shenzhen, China 2. General Description of EUT EUT Name : WIRELESS CHARDING POWER BANK Model(s) : PB147ACW, HIT#2896BLK, HIT#2896WHT, #2756Chi-Charge Plus Product Description : Operation Frequency: 110KHz-205KHz Modulation Type: ASK Antenna: Coil Antenna Power Supply : AC Input:110-240V~ 0.15A 50/60Hz Micro USB Input: 5V2A (Max) USB Output: 5V2.1A (Max) Cable Output1: 5V2.1A (Max) Cable Output2: 5V2.1A (Max) Cable Output3: 5V2.1A (Max) Wireless Output: 5V1A Max Output:5V2.1A (shared) Wireless Charging: 5W(Max) DC 3.7V by 5000mAh Rechargeable Li-ion battery Software Version : ---- Hardware Version : ---- Connecting I/O Port(S) : : Please refer to the User's Manual Accessories : HUAWEI Mate 40 PRO Note: More test information about the EUT please refer the RF Test Report. Report No.: TBR-C-202210-0059-2 Page: 2 of 29 TB-RF-074-1.0 RF Exposure Considerations 1. Measuring Standard KDB 680106 D01 RF Exposure Wireless Charging App v03. 2. Requirements According to the item 5.2 of KDB 680106 D01v03: Inductive wireless power transfer applications that meet all of the following requirements are excluded from submitting an RF exposure evaluation: (1) Power transfer frequency is less than 1 MHz. (2) Output power from each primary coil is less than or equal to 15 watts. (3) The transfer system includes only single primary and secondary coils. This includes charging systems that may have multiple primary coils and clients that are able to detect and allow coupling only between individual pairs of coils. (4) Client device is placed directly in contact with the transmitter. (5) Mobile exposure conditions only (portable exposure conditions are not covered by this exclusion). (6) The aggregate H-field strengths at 15 cm surrounding the device and 20 cm above the top surface from all simultaneous transmitting coils are demonstrated to be less than 50% of the MPE limit. Limits For Maximum Permissible Exposure (MPE) Report No.: TBR-C-202210-0059-2 Page: 3 of 29 TB-RF-074-1.0 3. Test Setup Ac Mode Note: The aggregate H-field strengths at 15 cm surrounding the device and 20 cm above the top surface. Battery Mode Note: The aggregate H-field strengths at 0-20 cm surrounding the device and 0-20 cm above the top surface. 15cm Report No.: TBR-C-202210-0059-2 Page: 4 of 29 TB-RF-074-1.0 4.Test Procedure For Mobile RF Exposure: 1) The RF exposure test was performed in anechoic chamber. 2) The aggregate H-field strengths at 15 cm surrounding the device and 20 cm above the top surface. 3) The highest emission level was recorded and compared with limit as soon as measurement of each points (A, B, C, D, E) were completed. 4) The EUT was measured according to the dictates of KDB 680106 D01 v03. Remark: The EUT’s test position A, B, C, D and E is valid for the E and H field measurements. For Portable RF Exposure: a) The RF exposure test was performed on 360 degree turn table in anechoic chamber. b) The measurement probe was placed at test distance (from 0 cm to 20cm, in 2 cm maximum increment) which is between the edge of the charger and the geometric center of probe. c) The highest emission level was recorded and compared with limit as soon as measurement of each points (A, B, C, D, E, F) were completed. d) The EUT were measured according to the dictates of KDB 680106 D01v03r01 Report No.: TBR-C-202210-0059-2 Page: 5 of 29 TB-RF-074-1.0 5. Equipment Approval Considerations The EUT does comply with item 5.2 of KDB 680106 D01v03 as follows table; Requirements of KDB 680106 D01 Yes / No Description Power transfer frequency is less than 1 MHz Yes The device operate in the frequency range 110.0 KHz - 205 KHz Output power from each primary coil is less than 15 watts Yes The maximum output power of the primary coil is 15W. The transfer system includes only single primary and secondary coils. This includes charging systems that may have multiple primary coils and clients that are able to detect and allow coupling only between individual pairs of coils. Yes The transfer system includes only single coil. Client device is placed directly in contact with the transmitter. Yes Client device is placed directly in contact with the transmitter. Mobile exposure conditions only (portable exposure conditions are not covered by this exclusion). No portable exposure conditions and mobile exposure conditions (Specific reference TCB Workshop Wireless Power Transfer Updates) The aggregate H-field strengths at 15 cm surrounding the device and 20 cm above the top surface from all simultaneous transmitting coils are demonstrated to be less than 50% of the MPE limit. Yes The EUT H-field strengths at 15 cm surrounding the device and 20 cm above the top surface from all simultaneous transmitting coils are demonstrated to be less than 50% of the MPE limit. In all other cases, unless excluded above, an RF exposure evaluation report must be reviewed and accepted through a KDB or PBA inquiry to enable authorization of the equipment. When evaluation is required to show compliance; for example, using field strength, power density, SAR measurements or computational modeling etc., the specific authorization requirements will be determined based on the results of the RF exposure evaluation 6. Test Equipment List Equipment Manufacturer Model No. Serial No. Last Cal. Cal. Due Date Magnetic field meter NARDA ELT-400 EE030 Sep.…

Text truncated - open the document above for the full version.

Test Report

Shenzhen Toby Technology Co., Ltd. Report No.: TBR-C-202210-0059-1 Page: 1 of 22 TB-RF-074-1.0 1/F.,Building 6, Rundongsheng Industrial Zone, Longzhu, Xixiang, Bao'an District, Shenzhen, Guangdong, China Tel: +86 75526509301 Fax: +86 75526509195 FCC Part 18 Test Report FCC ID: 2A825-PB147ACW Report No. : TBR-C-202210-0059-1 Applicant : Shen Zhen South Fortune Technology Co., Ltd. Equipment Under Test (EUT) EUT Name : WIRELESS CHARDING POWER BANK Model No. : PB147ACW Series Model No. : PB147W, HIT#2896BLK, HIT#2896WHT, #2756Chi-Charge Plus Brand Name : Heloideo, PneuATP, TWINTECH Receipt Date : 2022-10-19 Test Date : 2022-10-19 to 2022-10-26 Issue Date : 2022-10-26 Standards : FCC 47 CFR Part 18 Conclusions : PASS In the configuration tested, the EUT complied with the standards specified above. Test/Witness Engineer : Camille Li Engineer Supervisor : Ivan Su Engineer Manager : Ray Lai This report details the results of the testing carried out on one sample. The results contained in this test report do not relate to other samples of the same product. The manufacturer should ensure that all products in series production are in conformity with the product sample detailed in the report. Report No.: TBR-C-202210-0059-1 Page: 2 of 22 TB-RF-073-1.0 Contents CONTENTS ............................................................................................................................................. 2 1. GENERAL INFORMATION ...................................................................................................... 4 1.1 Client Information ................................................................................................................. 4 1.2 General Description of EUT (Equipment Under Test) ................................................... 4 1.3 Block Diagram Showing The Configuration of System Tested..................................... 5 1.4 Description of Support Units .............................................................................................. 5 1.5 Description of Test Mode .................................................................................................... 6 1.6 Test Location ........................................................................................................................ 7 1.7 Measurement Uncertainty .................................................................................................. 7 2. TEST SUMMARY ....................................................................................................................... 8 3. TEST SOFTWARE ..................................................................................................................... 8 4. TEST EQUIPMENT USED ....................................................................................................... 9 5. CONDUCTED EMISSION TEST ........................................................................................... 10 5.1 Test Standard and Limit .................................................................................................... 10 5.2 Test Setup ........................................................................................................................... 10 5.3 Test Procedure ................................................................................................................... 10 5.4 Deviation ............................................................................................................................. 11 5.5 Deviation From Test Standard ......................................................................................... 11 5.6 Test Data ............................................................................................................................. 11 6. RADIATED EMISSION TEST ................................................................................................ 12 6.1 Test Standard and Limit .................................................................................................... 12 6.2 Test Setup ........................................................................................................................... 13 6.3 Test Procedure ................................................................................................................... 13 6.4 Deviation ............................................................................................................................. 14 6.5 Deviation From Test Standard ......................................................................................... 14 6.6 Test Data ............................................................................................................................. 14 ATTACHMENT A--CONDUCTED EMISSION TEST DATA ........................................................ 15 ATTACHMENT B-- RADIATED EMISSION TEST DATA ............................................................ 17 Report No.: TBR-C-202210-0059-1 Page: 3 of 22 TB-RF-073-1.0 Revision History Report No. Version Description Issued Date TBR-C-202210-0059-1 Rev.01 Initial issue of report 2022-10-26 Report No.: TBR-C-202210-0059-1 Page: 4 of 22 TB-RF-073-1.0 1. General Information 1.1 Client Information Applicant : Shen Zhen South Fortune Technology Co., Ltd. Address : 4th Floor, Building C, Ganghua High-tech park, Nanwan Street, Buji Town, Longgang District, Shenzhen, China Manufacturer : Shen Zhen South Fortune Technology Co., Ltd. Address : 4th Floor, Building C, Ganghua High-tech park, Nanwan Street, Buji Town, Longgang District, Shenzhen, China 1.2 General Description of EUT (Equipment Under Test) EUT Name : WIRELESS CHARDING POWER BANK Models No. : PB147ACW, PB147W, HIT#2896BLK, HIT#2896WHT, #2756Chi-Charge Plus Model Difference : All PCB boards and circuit diagrams are the same, the only difference is that names. Product Description : Operation Frequency: 110KHz-205KHz Modulation Type: ASK Antenna: Coil Antenna Power Rating : AC Input:110-240V~ 0.15A 50/…

Text truncated - open the document above for the full version.

Test Setup Photos

FCC ID:2A825-PB147ACW TB-RF-074-1.0 Appendix IV EUT Test Photographs Test Setup Radiated Emission Test Setup(30MHz-1GHz) AC Mode: EUT+Load Radiated Emission Test Setup(30MHz-1GHz) Battery mode: EUT+Load FCC ID:2A825-PB147ACW TB-RF-074-1.0 Radiated Emission Test Setup(9KHz-30MHz) AC Mode: EUT+Load Radiated Emission Test Setup(9KHz-30MHz) Battery mode: EUT+Load FCC ID:2A825-PB147ACW TB-RF-074-1.0 Conducted Emission Test Setup AC Mode: EUT+Load -----END OF REPORT-----

Contact Information

Applicant

Sandy Zhang(Manager)
[email protected]15019248936Fax: N/A

Technical Contact

Shen Zhen South Fortune Technology Co., Ltd.
[email protected]

China

Test Firm

Shenzhen Toby Technology Co., Ltd.Ray Lai
[email protected]---

Technical Specifications

#Rule PartsFrequency RangePower Output
1180.11 MHz - 0.205 MHz-
Confidentiality
Long Term