FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Aeterlink Corp./
  3. 2A82S-13EA2A82S

2A82S-13EA2A82S920MHz WPT device

Aeterlink Corp.
920MHz WPT device - FCC ID 2A82S-13EA2A82S - Aeterlink Corp.
Click to zoom

Application Details

Equipment Class
8CC - Part 18 Consumer Device
Date of Grant
Aug 31, 2024
Application Purpose
Original Equipment
Date of Application
Aug 29, 2024
Equipment Note
920MHz WPT device
Frequency Range
918.00000000 - 918.00000000
Company
Aeterlink Corp.
Country
Japan

Documents & Files

Select a file to view

Users Manual

↗

Attestation Statements

↗
↗

Cover Letter(s)

↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

ALTD-IM-PTXMP-220719A-R10 1 Transmitter PTXMP <T01AAA> Instruction manual (Indoor use only) ■Overview This unit is a 920MHz band microwave wireless power supply transmitter. The output frequency is fixed at 918.0MHz at the factory. Operating frequency: 918MHz Modulation: N/A (CW) ANT Configuration: Dipole ANT Gain: <=6 dBi Crystal: TCXO 33.6MHz ■Main body (upper surface) Appearance ■Main body (lower surface) Appearance 〇 Description There is a power connector (IN) and a daisy-chain connector (OUT) (not in use). The pinouts are as follows: ALTD-IM-PTXMP-220719A-R10 2 ■Main unit (front) 〇Appearance 〇 LED Indicator LED Ind. Status Content P1 Power Off Powered off Green On Powered on Red On Error in power circuit D1 Tx Out Off Tx Power off Red On Tx Power on P2 Not in use D2 Not in use ■Main unit (right side) 〇Appearance ■Main body (left side) 〇Appearance ■ Main body (connector side) 〇Appearance ALTD-IM-PTXMP-220719A-R10 3 ■AC Adapter (example) 〇Appearance 〇 Description This is an AC adapter used when operating this unit at AC100V~240V/2A, and supplies DC24Vto this unit. With this AC adapter. 〇 Preparation Connect the M12 connector (Power) to the left-hand side of the connector shown below. One adaptor supplies the power to the one transmitter. The right-hand side of the connector is not in use. Connect the AC adaptor to the AC100V power outlet. 〇 Operation (Indoor Use Only) Once the AC adapter is connected to M12 connector, PTXMP starts running, and Tx power is on. To turn it off, disconnect the AC adapter. Note: The PTXMP transmitter shall be installed by professionals on an indoor structure that is not accessible to outsiders. PTXMP device needs to be installed in a fully enclosed, waterproof room in an indoor structure and cannot be accessed by non-professionals. TURNING ON Connect M12 connector cable to Transmitter Connect M12 connector cable to AC Adaptor Connect AC adaptor to power outlet ALTD-IM-PTXMP-220719A-R10 4 TURNING Off or ■Others・Precautions and considerations This device will be a PoC/evaluation device which can be available upon PoC/Evaluation request and agreement with Aeterlink Corp. directly and requires indoor operation only such as office environment. It does not have such functions as water and dust resistance. Aeterlink provides the users/customers who will be involved in the PoC/evaluation with further pre- cautions and warnings in terms of the possible radio exposure in person when delivery of DUTs. A sticker saying “Always keep distance from DUT by >2 inches (~50mm)” will be placed on the surface of the DUTs. Since it is a device that emits radio waves, please use it within the scope of the Radio Law as well. The transmitter can be installed on either wall or pillar with four bolts with washers by professionals. There are four bolt holes at each corner. See photos below. Recommended bolt: M4 with flat washer Recommended tightening torque: 1.3±0.2N·m The actual use distance: 50mm ~ 6,000mm (effective range). The maximum number of devices that can be charged simultaneously: 300 devices sitting within the effective range mentioned above. Note: The distance is subject to vary due to the environment and usage conditions but for the typical use case. Refer to Supplemental Information at the end of this document. The minimum distance from PTXMP to avoid RF exposure for safety: 50mm. During operation, the temperature of the backside metal part increases. Short-term skin contact will not cause immediate burns, but please be careful when handling during operation or immediately after stopping. FCC CAUTION Note: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance Disconnect AC adaptor from power outlet Disconnect M12 connector cable from Transmitter ALTD-IM-PTXMP-220719A-R10 5 with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense. This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment and meets the FCC radio frequency (RF) Exposure Guidelines. This equipment has very low levels of RF energy that is deemed to comply without maximum permissive exposure evaluation (MPE). FCC Warning This equipment has been tested and found to comply with Part 18 of the FCC Rules. ‧The interference potential of the device or system. ‧Maintenance of the system. ‧Simple measures that can be taken by the user to correct interference. ‧For RF lighting devices, provide an advisory statement, either on the product packaging or with other user documentation, similar to the following: This product may cause interference to radio equipment and should not be installed near maritime safety communications equipment or other critical navigation or communication equipment operating between 0.45-30 MHz. FCC Radiation Exposure Statement This equipment complies with FCC RF radiation exposure limits set forth for an uncontrolled environment. This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter. ALTD-IM-PTXMP-220719A-R10 6 Supplemental Information. Technical discussion of usable distance and the number of serviceable receivers (1) Serviceable Distance ・ The operable range of the receiver is 0.01mW~300mW in power. Refer to the table below for the theoretical distance range. The operable distance is approximately 50mm~6000mm. (The minimum required power to activate the receiver is 0.01mW and 300mW is the maximum allowable power to the protection circutry.) Freq λ Distance TX…

Text truncated - open the document above for the full version.

Attestation Statements

V02072023 Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 USA Date: 07/24/2023 Ref: Attestation Statement Part 2.911(d)(7) Filing Validity Period: Permanent FCC ID: 2A82S-13EA2A82S Model Name: PTXMP Manufacturer Name Aeterlink Corp. Address Ohtemachi Building 6F #671 1-6-1 Ohtemachi Chiyoda-ku 1000004 Japan FCC FRN 0033005646 certifies that, as of the dates of this application, Americas Compliance Consulting LLC dba iCertifi “iCertifi” is our designated U.S. agent for service of process for the above referenced FCC ID. We accept to maintain an agent for no less than one year after the grantee has terminated all marketing and importation or the conclusion of any commission-related proceeding involving the equipment. The US Agent for Service of Process is aware of and agrees to comply with the requirements outlined in the FCC Equipment Authorization Program, Report and Order FCC 22-84, and clause § 2.911. iCertifi accepts, as of the date of the filing of the application, the obligation of the designated U.S. agent for service process for the above: Designated U.S. Agent Information: Name Americas Compliance Consulting, LLC dba iCertifi FCC FRN 0033399411 Address 1001 SW Disk Drive, Suite 250 Bend, Oregon 97702 USA Contact Person Paul Preston Telephone (866) 885-4575 Email [email protected] Sincerely, Aeterlink Corporation Americas Compliance Consulting LLC dba iCertifi Shoichi Matsuura Paul Preston Signature

Attestation Statements

Covered list attestation FCC application letter Kiwa Page 1 of 2 RF_755_02 15-02-2023 Aeterlink Corp. Certification Application Attestation Statements Aeterlink Corp. Ohtemachi Building 6F #671 1-6-1 Ohtemachi Chiyoda-ku 1000004 Japan Subject: FCC ID: 2A82S-13EA2A82S To Whom It May Concern: Statement for 47 CFR section 2.911(d)(5)(i) [Aeterlink Corp.] certifies that as of the date of the application the equipment for which authorization is sought is not “covered” equipment 1 prohibited from receiving an equipment authorization pursuant to section 2.903 of the FCC rules. If the equipment for which the applicant seeks authorization is produced by any of the entities identified on the current Covered List, including affiliates or subsidiaries of the named companies, the applicant must include an explanation on why the equipment is not “covered” equipment. Addit ional Explanation: <N/A> Statement for 47 CFR section 2.911(d)(5)(ii) [Aeterlink Corp.] (“the applicant”) certifies that, as of the date of the filing of this application, the applicant - is / - is not (3) identi fied on the Covered List as an entity producing “covered” equipment. Date: 2023-06-16 City: Chiyoda-ku Name (2) : Shoichi Matsuura Function: Sr. QA Manager Telephone number: +819085144714 Email address: [email protected] Signature: 1 - The Commission’s Covered List is published by the Public Safety and Homeland Security Bureau and posted on the Commission’s website. This Covered List, which is periodically updated, identifies particular equipment, produced by particular entities, that constitutes “covered” equipment. https://www.fcc.gov/supplychain/coveredlist . (2): For FCC it must be the Grantee Code “owner” or the authorized agent. (3): double click on the appropriate box and select ‘’checked” then “OK”

Cover Letter(s)

RF_160_05 Declaration of Authorisation Date of issue 02-01-2023 Declaration of Authorization We Name: Ad dress: City: Country: Aeterlink Corp. Ohtemachi Building 6F #671 1-6-1 Ohtemachi Chiyoda-ku 1000004 J apan Decla re that: Name Representative of agent: Chieh Tseng Agent Company name: Worldwide Testing Services (Taiwan) Co., Ltd. Address: 6F., No. 58, Lane 188, Ruey Kuang Road, Neihu Dist., City: Taipei City 114, Country Taiwan is author ized to apply for Certification of the following product(s): Produc t description: 920MHz WPT device Type designation: PTXMP Trademark: AirPlug TM Validity/ expiry date on our behal f. Date: 2023-06-16 City: C hiyoda-ku Name: Shoichi Matsuura Function: Sr . QA Manager Signature: Notes: (1): Required for FCC application (2): For FCC it must be the Grantee Code “owner” or the authorized agent.

Cover Letter(s)

FCC, Request for non-disclosure Date: 02-01-2022 RF_501, Issue 10 Company Name: Aeterlink Corp. Address : Ohtemachi Building 6F #671 1-6-1 Ohtemachi City: Country: Chiyoda-ku 1000004 Japan To: Kiwa N etherlands B.V., Dept. FCC TCB Wilmersdorf 50 7327 AC Apeldoorn The Net herlands Subject: Request for confidentiality FCC ID: 2A82S-13EA2A82S Reference number: 0033005646 Dear FCC TCB, 1. Long-Te rm Confidentiality Pursuant to 47 CFR Section 0.459(a) & (b), we hereby requests non-disclosure and confidential treatment of the following materials submitted in support of FCC certification application: Bill(s) of Material Block Diagrams Operational Description Schematic Diagrams Tune-up Procedure Above materials contain secrets, proprietary and technical information, which would customarily be guarded from competitors under 47 CFR, section 0.457(d)(2). Disclosure or publication or any portion of this company confidential material to other parties could cause substantial competitive harm and provide unjustified benefits for competitors. 2. Short-Term Confidentiality (STC) Pursuant to Public Notice DA 04-1705 of the Commission’s policy, in order to comply with the marketing regulations in 47 CFR §2.803 and the importation rules in 47 CFR §2.1204, a pplicant hereby requests Short-Term Confidential treatment of the following materials (See notes below): Internal Photos User’s Manual Test Set-up Photos External Photos Justification: Date: 2023-06-16 Name and signature of applicant: Shoichi Matsuura Notes: 1) A document or type of document can only have ONE type of confidentiality! 2) Short-Term confidentiality is in principle for 45 days from date of grant; it can be extended max 3 times (total time 180 days max.)! The planned date should state in the RF731 application form. 3) FCC must be informed when marketing begins earlier. 4) Release takes place automatically thus extension must be requested in time. Telefication does not remind you of this! 5) Request for extension or for release must be received by Kiwa NL B.V. at least 7 days before date of actual marketing or before expiration of the STC period

External Photos

Registration number: W6M22212-22340-FCC FCC ID: 2A82S-13EA2A82S Worldwide Testing Services(Taiwan) Co., Ltd. Appendix page 2 of 34 External Photos Registration number: W6M22212-22340-FCC FCC ID: 2A82S-13EA2A82S Worldwide Testing Services(Taiwan) Co., Ltd. Appendix page 3 of 34 Registration number: W6M22212-22340-FCC FCC ID: 2A82S-13EA2A82S Worldwide Testing Services(Taiwan) Co., Ltd. Appendix page 4 of 34 Registration number: W6M22212-22340-FCC FCC ID: 2A82S-13EA2A82S Worldwide Testing Services(Taiwan) Co., Ltd. Appendix page 5 of 34 Registration number: W6M22212-22340-FCC FCC ID: 2A82S-13EA2A82S Worldwide Testing Services(Taiwan) Co., Ltd. Appendix page 6 of 34 Registration number: W6M22212-22340-FCC FCC ID: 2A82S-13EA2A82S Worldwide Testing Services(Taiwan) Co., Ltd. Appendix page 7 of 34 Registration number: W6M22212-22340-FCC FCC ID: 2A82S-13EA2A82S Worldwide Testing Services(Taiwan) Co., Ltd. Appendix page 8 of 34 Registration number: W6M22212-22340-FCC FCC ID: 2A82S-13EA2A82S Worldwide Testing Services(Taiwan) Co., Ltd. Appendix page 9 of 34

ID Label/Location Info

Design of Label FCC ID: 2A82S-13EA2A82S Location of Label Bottom plate

Internal Photos

Registration number: W6M22212-22340-FCC FCC ID: 2A82S-13EA2A82S Worldwide Testing Services(Taiwan) Co., Ltd. Appendix page 10 of 34 Internal Photos Registration number: W6M22212-22340-FCC FCC ID: 2A82S-13EA2A82S Worldwide Testing Services(Taiwan) Co., Ltd. Appendix page 11 of 34 Registration number: W6M22212-22340-FCC FCC ID: 2A82S-13EA2A82S Worldwide Testing Services(Taiwan) Co., Ltd. Appendix page 12 of 34 Registration number: W6M22212-22340-FCC FCC ID: 2A82S-13EA2A82S Worldwide Testing Services(Taiwan) Co., Ltd. Appendix page 13 of 34 Registration number: W6M22212-22340-FCC FCC ID: 2A82S-13EA2A82S Worldwide Testing Services(Taiwan) Co., Ltd. Appendix page 14 of 34 Registration number: W6M22212-22340-FCC FCC ID: 2A82S-13EA2A82S Worldwide Testing Services(Taiwan) Co., Ltd. Appendix page 15 of 34 Registration number: W6M22212-22340-FCC FCC ID: 2A82S-13EA2A82S Worldwide Testing Services(Taiwan) Co., Ltd. Appendix page 16 of 34 Registration number: W6M22212-22340-FCC FCC ID: 2A82S-13EA2A82S Worldwide Testing Services(Taiwan) Co., Ltd. Appendix page 17 of 34 Registration number: W6M22212-22340-FCC FCC ID: 2A82S-13EA2A82S Worldwide Testing Services(Taiwan) Co., Ltd. Appendix page 18 of 34 Registration number: W6M22212-22340-FCC FCC ID: 2A82S-13EA2A82S Worldwide Testing Services(Taiwan) Co., Ltd. Appendix page 19 of 34 Registration number: W6M22212-22340-FCC FCC ID: 2A82S-13EA2A82S Worldwide Testing Services(Taiwan) Co., Ltd. Appendix page 20 of 34 Registration number: W6M22212-22340-FCC FCC ID: 2A82S-13EA2A82S Worldwide Testing Services(Taiwan) Co., Ltd. Appendix page 21 of 34

RF Exposure Info

of Applicant: Aeterlink Corp. Address: Ohtemachi Building 6F #671 1-6-1 Ohtemachi Chiyoda-ku 1000004 Japan Tested and Prepared by Worldwide Testing Services (Taiwan) Co., Ltd. FCC Registration No.: TW1072, TW1140, TW1146, TW1477, TW0037 Industry Canada filed test laboratory Reg. No.: 20037, 31634 Report No.: W6M22212-22340-EE 6F, NO. 58, LANE 188, RUEY-KUANG RD., NEIHU TAIPEI 114, TAIWAN, R.O.C. TEL: 886-2-66068877 FAX: 886-2-66068879 E- mail: [email protected] FCC RF Exposure Exemption report for 920MHz WPT device Model No.: PTXMP FCC ID: 2A82S-13EA2A82S Registration number: W6M22212-22340-EE FCC ID: 2A82S-13EA2A82S Worldwide Testing Services(Taiwan) Co., Ltd. Page 1 of 8 TABLE OF CONTENTS 1 GENERAL INFORMATION ......................................................................................................................................... 2 1.1 NOTES ...................................................................................................................................................................... 2 1.2 TESTING LABORATORY ............................................................................................................................................. 3 1.3 APPLICATION DETAILS .............................................................................................................................................. 3 1.4 GENERAL INFORMATION OF TEST ITEM ..................................................................................................................... 4 1.5 TEST STANDARDS ..................................................................................................................................................... 4 2 TEST CONFIGURATION ............................................................................................................................................. 5 2.1 TEST ENVIRONMENT ................................................................................................................................................. 5 2.2 MEASUREMENT UNCERTAINTY ................................................................................................................................. 5 2.3 TEST EQUIPMENT LIST .............................................................................................................................................. 5 3 EQUIVALENT ISOTROPIC RADIATED POWER (EIRP) ...................................................................................... 6 3.1 EXEMPTION LIMITS FOR ROUTINE EVALUATION ...................................................................................................... 7 Registration number: W6M22212-22340-EE FCC ID: 2A82S-13EA2A82S Worldwide Testing Services(Taiwan) Co., Ltd. Page 2 of 8 1 General Information 1.1 Notes The purpose of conformity testing is to increase the probability of adherence to the essential requirements or conformity specifications, as appropriate. The complexity of the technical specifications, however, means that full and thorough testing is impractical for both technical and economic reasons. Furthermore, there is no guarantee that a test sample which has passed all the relevant tests conforms to a specification. Neither is there any guarantee that such a test sample will interwork with other genuinely open systems. The existence of the tests nevertheless provides the confidence that the test sample possesses the qualities as maintained and that is performance generally conforms to representative cases of communications equipment. Laboratory disclaimer- 1. The test results of this test report relate exclusively to the item tested as specified in 1.5. 2. The test report may only be reproduced or published in full. 3. Reproduction or publication of extracts from the report requires the prior written approval of the Worldwide Testing Services(Taiwan) Co., Ltd. 4. Antenna gain is provided by applicant and laboratory issue relevant data and results. Tester: August 28, 2024 Ken Kang Date WTS-Lab. Name Signature Technical responsibility for area of testing: August 28, 2024 Kevin Wang Date WTS Name Signature Registration number: W6M22212-22340-EE FCC ID: 2A82S-13EA2A82S Worldwide Testing Services(Taiwan) Co., Ltd. Page 3 of 8 1.2 Testing laboratory 1.2.1 Location 10m OATS No.5-1, Lishui, Shuang Sing Village, Wanli Dist., New Taipei City 207, Taiwan (R.O.C.) Xizhi Lab No. 99, Sec. 1, Balian Rd., Xizhi Dist., New Taipei City 221032, Taiwan (R.O.C.) Worldwide Testing Services (Taiwan) Co., Ltd. 6F., No. 58, Ln. 188, Ruiguang Rd., Neihu Dist., Taipei City 114 , Taiwan (R.O.C.) Tel: 886-2-6606-8877 1.2.2 Details of accreditation status Accredited testing laboratory FCC filed test laboratory Reg. No.: TW1072, TW1140, TW1146, TW1477, TW0037 Industry Canada filed test laboratory Reg. No.: 20037, 31634 Test location, where different from Worldwide Testing Services (Taiwan) Co., Ltd. : Name: ./. Accredited no.: ./. Street: ./. Town: ./. Country: ./. 1.3 Application details Approval holder Name: Aeterlink Corp. Street: Ohtemachi Building 6F #671 1-6- 1 Ohtemachi Town: Chiyoda-ku 1000004 Country: Japan Manufacturer: (if applicable) Name: (K) LIMNO Street: 7- 101 Tachikawa-cho, Town: Tottori-shi, Tottori Pref. 680- 8634, Country: Japan Registration number: W6M22212-22340-EE FCC ID: 2A82S-13EA2A82S Worldwide Testing Services(Taiwan) Co., Ltd. Page 4 of 8 Test date Date of receipt of test item: May 12, 2023 Date of test: from May 15, 2023 to August 02, 2024 1.4 General information of Test item Type of test item: 920MHz WPT device Model number: PTXMP Multi-listing model number: ./. Brand name: AirPlug TM Transmitting frequency: 918MHz Power supply: Adaptor (I/P: 100-240V~50/60Hz 0.6A O/P: 24V⎓1000mA) Technical data Max output power: 30.30 dBm Operation modes: Simplex Sample no.: #01 Special statement: ./. Classification: Fixed Device Mobile Device (Human Body distance > 20cm) Portable Device (Human Body distance < 20cm) 1.5 Test standards 47 CFR FCC Part …

Text truncated - open the document above for the full version.

Test Report

Of Applicant: Aeterlink Corp. Address: Ohtemachi Building 6F #671 1-6-1 Ohtemachi Chiyoda-ku 1000004 Japan Tested and Prepared By Worldwide Testing Services (Taiwan) Co., Ltd. FCC Registration No.: TW1477, TW1072 Industry Canada filed test laboratory Reg. No.: 20037, 5107A Report No.: W6M22212-22340-P-18 6F, NO. 58, LANE 188, RUEY-KUANG RD., NEIHU TAIPEI 114, TAIWAN, R.O.C. TEL: 886-2-66068877 FAX: 886-2-66068879 E- mail: [email protected] 47 CFR PART 18 TEST REPORT for 920MHz WPT device Model No.: PTXMP FCC ID: 2A82S-13EA2A82S Registration number: W6M22212-22340-P-18 FCC ID: 2A82S-13EA2A82S Worldwide Testing Services(Taiwan) Co., Ltd. Page 1 of 24 TABLE OF CONTENTS 1 GENERAL INFORMATION .......................................................................................................................................... 2 1.1 NOTES .......................................................................................................................................................................... 2 1.2 TESTER ........................................................................................................................................................................ 3 1.3 TESTING LABORATORY ................................................................................................................................................ 4 1.3.1 Location .............................................................................................................................................................. 4 1.3.2 Details of accreditation status ............................................................................................................................ 4 1.3.3 Test location, where different from Worldwide Testing Services (Taiwan) Co., Ltd. ......................................... 4 1.4 DETAILS OF APPLICANT ................................................................................................................................................ 5 1.5 APPLICATION DETAILS ................................................................................................................................................. 5 1.6 TEST ITEM .................................................................................................................................................................... 5 1.6.1 Description of test item ....................................................................................................................................... 5 1.6.2 Manufacturer (if different from applicant in point 1.4) ...................................................................................... 6 1.6.3 Kind of application ............................................................................................................................................. 6 1.7 TEST STANDARDS ......................................................................................................................................................... 6 1.8 TEST CONFIGURATION.................................................................................................................................................. 6 2 TECHNICAL TEST ......................................................................................................................................................... 7 2.1 SUMMARY OF TEST RESULTS ........................................................................................................................................ 7 2.2 TEST ENVIRONMENT .................................................................................................................................................... 7 2.3 TEST EQUIPMENT UTILIZED .......................................................................................................................................... 8 2.4 TEST RESULTS ............................................................................................................................................................ 11 2.4.1 Conducted Emission .......................................................................................................................................... 12 2.4.2 Radiated Emission ............................................................................................................................................ 13 2.4.3 Operating frequencies ....................................................................................................................................... 14 2.4.4 Power measurement .......................................................................................................................................... 14 2.5 TEST PROTOCOLS ....................................................................................................................................................... 15 2.5.1 Radiated Emission ............................................................................................................................................ 15 2.5.2 Radiated Emission ............................................................................................................................................ 21 2.6 EQUIPMENT MODIFICATION ....................................................................................................................................... 23 NORMATIVE REFERENCES ............................................................................................................................................. 24 Registration number: W6M22212-22340-P-18 FCC ID: 2A82S-13EA2A82S Worldwide Testing Services(Taiwan) Co., Ltd. Page 2 of 24 1 General Information 1.1 Notes The purpose of conformity testing is to increase the probability of adherence to the essential requirements or conformity specifications, as appropriate. The tests were carried out and passed in accordance to the standards: 47 CFR Part 18 : October 2021 The complexity of …

Text truncated - open the document above for the full version.

Test Setup Photos

Registration number: W6M22212-22340-FCC FCC ID: 2A82S-13EA2A82S Worldwide Testing Services(Taiwan) Co., Ltd. Appendix page 22 of 34 Set Up Photo of Radiated Emission EMI Below 1GHz Registration number: W6M22212-22340-FCC FCC ID: 2A82S-13EA2A82S Worldwide Testing Services(Taiwan) Co., Ltd. Appendix page 23 of 34 Above 1GHz Registration number: W6M22212-22340-FCC FCC ID: 2A82S-13EA2A82S Worldwide Testing Services(Taiwan) Co., Ltd. Appendix page 24 of 34 Registration number: W6M22212-22340-FCC FCC ID: 2A82S-13EA2A82S Worldwide Testing Services(Taiwan) Co., Ltd. Appendix page 25 of 34 RF Part 15.209 Below 1GHz Registration number: W6M22212-22340-FCC FCC ID: 2A82S-13EA2A82S Worldwide Testing Services(Taiwan) Co., Ltd. Appendix page 26 of 34 Above 1GHz Registration number: W6M22212-22340-FCC FCC ID: 2A82S-13EA2A82S Worldwide Testing Services(Taiwan) Co., Ltd. Appendix page 27 of 34 Registration number: W6M22212-22340-FCC FCC ID: 2A82S-13EA2A82S Worldwide Testing Services(Taiwan) Co., Ltd. Appendix page 28 of 34 KDB 680106 Test Position 1 Test Position 2 Registration number: W6M22212-22340-FCC FCC ID: 2A82S-13EA2A82S Worldwide Testing Services(Taiwan) Co., Ltd. Appendix page 29 of 34 Test Position 3 (15cm) Test Position 3 (100cm) Registration number: W6M22212-22340-FCC FCC ID: 2A82S-13EA2A82S Worldwide Testing Services(Taiwan) Co., Ltd. Appendix page 30 of 34 Test Position 3 (110cm) Test Position 4 Registration number: W6M22212-22340-FCC FCC ID: 2A82S-13EA2A82S Worldwide Testing Services(Taiwan) Co., Ltd. Appendix page 31 of 34 Test Position 5 Test Position 6 Registration number: W6M22212-22340-FCC FCC ID: 2A82S-13EA2A82S Worldwide Testing Services(Taiwan) Co., Ltd. Appendix page 32 of 34 Test Position 3 (15cm) Test Position 3 (100cm) Registration number: W6M22212-22340-FCC FCC ID: 2A82S-13EA2A82S Worldwide Testing Services(Taiwan) Co., Ltd. Appendix page 33 of 34 Test Position 7 (110cm) Registration number: W6M22212-22340-FCC FCC ID: 2A82S-13EA2A82S Worldwide Testing Services(Taiwan) Co., Ltd. Appendix page 34 of 34 Set Up Photo of Conducted Emission

Contact Information

Applicant

Shoichi Matsuura(Sr. QA Manager)
[email protected]+819085144714Fax: +81332134021

Technical Contact

Worldwide Testing Services (Taiwan) Co., Ltd.Kevin Wang
[email protected]+886266068877

6F., No.58, Lane 188, Ruey Kuand Rd., · Taiwan

Non-Technical Contact

Worldwide Testing Services (Taiwan) Co., Ltd.Chieh Tseng
[email protected]+886266068877

Test Firm

Worldwide Testing Services (Taiwan) Co., Ltd.Rex Kao
[email protected]886-2-6606-8877Fax: 886-2-6606-8879

Technical Specifications

#Rule PartsFrequency RangePower Output
118918 MHz - 918 MHz-
Confidentiality
Long Term