Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
Via Confortino, 30 I-40056 Valsamoggia, Loc. Crespellano (BO) – Italy Phone +39 051 738 111 Fax +39 051 738 441 www.group-itm.com Sede Legale – Registered Office Direzione e Uffici – Headquarters: Via Confortino, 30 – I-40056 Valsamoggia Loc. Crespellano (BO) - Italy Reg. Imp. 02929550362 – REA 461512 Cod. Fiscale 02929550362 – VAT IT 02929550362 Capitale sociale € 50.000.000 i.v. – Società soggetta a direzione e coordinamento di Titan ITM Holding SpA TI_ITM_022/0 1 Pictures PCB TOP: PCB BOTTOM: Via Confortino, 30 I-40056 Valsamoggia, Loc. Crespellano (BO) – Italy Phone +39 051 738 111 Fax +39 051 738 441 www.group-itm.com Sede Legale – Registered Office Direzione e Uffici – Headquarters: Via Confortino, 30 – I-40056 Valsamoggia Loc. Crespellano (BO) - Italy Reg. Imp. 02929550362 – REA 461512 Cod. Fiscale 02929550362 – VAT IT 02929550362 Capitale sociale € 50.000.000 i.v. – Società soggetta a direzione e coordinamento di Titan ITM Holding SpA TI_ITM_022/0 1 Final product pictures:
T h i s s i d e O U T TRUST ITM TM component Via Confortino 30, I-40056 Valsamoggia, Crespellano Bologna Italy Model: TCKT FCC ID: 2A845000TCKTX Rated: 3.0V; 10uA Made in Italy
Via Confortino, 30 I-40056 Valsamoggia, Loc. Crespellano (BO) – Italy Phone +39 051 738 111 Fax +39 051 738 441 www.group-itm.com Sede Legale – Registered Office Direzione e Uffici – Headquarters: Via Confortino, 30 – I-40056 Valsamoggia Loc. Crespellano (BO) - Italy Reg. Imp. 02929550362 – REA 461512 Cod. Fiscale 02929550362 – VAT IT 02929550362 Capitale sociale € 50.000.000 i.v. – Società soggetta a direzione e coordinamento di Titan ITM Holding SpA TI_ITM_022/0 1 Pictures PCB TOP: PCB BOTTOM: Via Confortino, 30 I-40056 Valsamoggia, Loc. Crespellano (BO) – Italy Phone +39 051 738 111 Fax +39 051 738 441 www.group-itm.com Sede Legale – Registered Office Direzione e Uffici – Headquarters: Via Confortino, 30 – I-40056 Valsamoggia Loc. Crespellano (BO) - Italy Reg. Imp. 02929550362 – REA 461512 Cod. Fiscale 02929550362 – VAT IT 02929550362 Capitale sociale € 50.000.000 i.v. – Società soggetta a direzione e coordinamento di Titan ITM Holding SpA TI_ITM_022/0 1 Final product pictures:
PRS LAB S.r.l. Unipersonale Sede operativa e Laboratori di prova Headquarter and Testing lab Via Campagna, 92 I 22020 Faloppio (CO) I Italy Tel. +39 031 3500011 I Fax +39 031 991309 [email protected] I www.primaricerca.it PRS LAB I Scegli bene, scegli Prima Rapporto di prova - Test report n. MPETR_181667-0 I Data - Date 28/10/2022 Pagina 1 di 11 RAPPORTO DI PROVA TEST REPORT Rif. / Ref. n. MPETR_181667-0 Data / Date: 28/10/2022 Pagine / Pages: 11 Scopo delle prove Test object Prove di tipo in accordo alla Norma Type test according to standards FCC Cfr 47 part 2 - §2.1093 RSS-102:2015 Richiedente Applicant Italtractor ITM S.p.a. Via confortino 30, 40056 Valsamoggia (BO) loc. Crespellano Marchio commerciale Trade mark Fabbricante Manufacturer Italtractor ITM S.p.a. Via confortino 30, 40053 Valsamoggia (BO) loc. Crespellano Prodotto Product Sensor BLE Modello testato Testing model TCKT50050 7 Identificativo FCC & IC FCC & IC ID 2A845000TCKTX Data ricevimento campioni Date of test samples receipt 30/06/2022 Campioni verificati No. of tested samples 1 – Sampled by the applicant Data verifiche Testing date From 07/07/2022 to 30/08/2022 Sito di prova Testing site PRSLAB S.r.l. Unipersonale - Via Campagna 92 - 22020 Faloppio - Como - Italy Esito delle valutazioni Assessment results CONFORME / COMPLIANT Verifiche effettuate da Verifications carried out by Daniele AOSANI Tecnico Laboratorio Laboratory Engineer Approvato Approved by Riccardo PFEIFFER Responsabile di Laboratorio Laboratory Manager The test results reported in this test report shall refer only to the samples tested. The sample has been provided by the customer and the results apply to the sample as received This report may not be partially reproduced, except with the prior written permission of the issuing Laboratory PRS refuses any responsibility about information provided by the customer contained in this test report. PRS LAB S.r.l. Unipersonale Sede operativa e Laboratori di prova - Headquarter and Testing lab: Via Campagna, 92 I 22020 Faloppio (CO) I Italy Tel. +39 031 3500011 I Fax +39 031 991309 [email protected] I www.primaricerca.it PRS LAB I Scegli bene, scegli Prima Rapporto di prova - Test report n. MPETR_181667-0 I Data - Date 28/10/2022 Pagina 2 di 11 Conformity Assessment Body Identifier (CABID) 5347A Identificativo FCC del sito di prova FCC designation number IT0012 PRS LAB S.r.l. Unipersonale Sede operativa e Laboratori di prova - Headquarter and Testing lab: Via Campagna, 92 I 22020 Faloppio (CO) I Italy Tel. +39 031 3500011 I Fax +39 031 991309 [email protected] I www.primaricerca.it PRS LAB I Scegli bene, scegli Prima Rapporto di prova - Test report n. MPETR_181667-0 I Data - Date 28/10/2022 Pagina 3 di 11 CONTENUTO TABLE OF CONTENTS 0. RELEASE CONTROL RECORD ..................................................................................................... 4 1. DECISION RULE ........................................................................................................................ 4 2. INFORMATION PROVIDED BY CUSTOMER ................................................................................. 5 3. GENERAL REMARKS ................................................................................................................. 4 4. TECHNICAL INFORMATION OF EQUIPMENT UNDER TEST (EUT) ................................................. 6 4.1 EUT Identification ......................................................................................................................... 6 4.2 Bluetooth Low Energy module technical data .............................................................................. 7 5. REFERENCE STANDARDS .......................................................................................................... 8 6. MEASUREMENTS AND CALCULATION RESULTS ......................................................................... 8 6.1 SAR exemption .............................................................................................................................. 8 6.2 Operational Description ................................................................................................................ 8 6.3 RF Exposure Conditions: ............................................................................................................... 8 6.1 RF Output Power: .......................................................................................................................... 9 6.1 FCC Calculation method and limits ............................................................................................... 9 6.2 FCC Calculation results .................................................................................................................. 9 6.3 ISED Calculation method and limits ............................................................................................ 10 6.4 ISED Calculation results............................................................................................................... 10 PRS LAB S.r.l. Unipersonale Sede operativa e Laboratori di prova - Headquarter and Testing lab: Via Campagna, 92 I 22020 Faloppio (CO) I Italy Tel. +39 031 3500011 I Fax +39 031 991309 [email protected] I www.primaricerca.it PRS LAB I Scegli bene, scegli Prima Rapporto di prova - Test report n. MPETR_181667-0 I Data - Date 28/10/2022 Pagina 4 di 11 0. RELEASE CONTROL RECORD TEST REPORT NUMBER REASON OF CHANGE DATE OF ISSUE MPETR_181667-0 Original Release 28/10/2022 This document is valid in last revision that deletes and replaces the previous one 1. DECISION RULE PRS LAB specifies that, if the decision rules of conformity of the test results are not indicated in detail in the standard/s object of tests, it takes as a decision rule for the declaration of conformity the simple binary system (w = 0) stated in the ILAC-G8-09:2019 document. The decision rule is applicable for all parts of standard Statements of conformity are repor…
Text truncated - open the document above for the full version.
PRS LAB S.r.l. Unipersonale Sede operativa e Laboratori di prova Headquarter and Testing lab Via Campagna, 92 I 22020 Faloppio (CO) I Italy Tel. +39 031 3500011 I Fax +39 031 991309 [email protected] I www.primaricerca.it Mod 18_48 rev05 Test Report FCCTR Rapporto di prova - Test report n. FCCTR_181667-0 I Data - Date 28/10/2022 Pagina 1 di 58 RAPPORTO DI PROVA TEST REPORT Rif. / Ref. n. FCCTR_181667-0 Data Emissione /Issue Date: 28/10/2022 Pagine / Pages: 58 Scopo delle prove Test object Prove di tipo in accordo alla Norme Type test according to Standards 47 CFR FCC part 15 - Subpart C - §15.247 ISED – RSS 247 Richiedente Applicant Italtractor ITM S.p.a. Via confortino 30, 40053 Valsamoggia (BO) loc. Crespellano Marchio commerciale Trade mark Fabbricante Manufacturer Italtractor ITM S.p.a. Via confortino 30, 40053 Valsamoggia (BO) loc. Crespellano Prodotto Product Sensor BLE Modello testato Testing model TCKT50000 Identificativo FCC FCC ID 2A845000TCKTX Data ricevimento campioni Date of test samples receipt 30/06/2022 Campioni verificati No. of tested samples 1 – Sampled by the applicant Data verifiche Testing date From 07/07/2022 to 30/08/2022 Sito di prova Testing site PRSLAB S.r.l. Unipersonale - Via Campagna 92 - 22020 Faloppio - Como - Italy Identificativo FCC del sito di prova FCC designation number IT0012 Esito delle valutazioni Assessment results CONFORME / COMPLIANT Verifiche effettuate da Verifications carried out by Daniele AOSANI Tecnico Laboratorio Laboratory Engineer Approvato Approved by Riccardo PFEIFFER Responsabile di Laboratorio Laboratory Manager The test results reported in this test report shall refer only to the samples tested. The sample has been provided by the customer and the results apply to the sample as received This report may not be partially reproduced, except with the prior written permission of the issuing Laboratory PRS refuses any responsibility about information provided by the customer contained in this test report. PRS LAB S.r.l. Unipersonale Sede operativa e Laboratori di prova Headquarter and Testing lab Via Campagna, 92 I 22020 Faloppio (CO) I Italy Tel. +39 031 3500011 I Fax +39 031 991309 [email protected] I www.primaricerca.it Mod 18_48 rev05 Test Report FCCTR Rapporto di prova - Test report n. FCCTR_181667-0 I Data - Date 28/10/2022 Pagina 2 di 58 CONTENUTO TABLE OF CONTENTS 0. RELEASE CONTROL RECORD ......................................................................................................... 3 1. DECISION RULE ............................................................................................................................ 3 2. INFORMATION PROVIDED BY CUSTOMER ..................................................................................... 4 3. GENERAL REMARKS ..................................................................................................................... 3 4. TECHNICAL INFORMATION OF EQUIPMENT UNDER TEST (EUT) ..................................................... 5 4.1 EUT Identification .............................................................................................................................. 5 4.2 Bluetooth Low Energy module technical data ................................................................................... 6 4.2.1 Channel List Bluetooth Low Energy .............................................................................................. 6 4.3 Ports identification ............................................................................................................................. 7 4.4 Modifications incorporated in E.U.T. ................................................................................................. 7 4.5 Auxiliary equipment ........................................................................................................................... 7 5. REFERENCE STANDARDS .............................................................................................................. 8 6. OPERATING TEST MODES AND TEST CONDITIONS ......................................................................... 8 7. SUMMERY OF TEST RESULTS ........................................................................................................ 9 8. UNITS OF MEASUREMENTS .......................................................................................................... 9 9. TEST RESULTS ............................................................................................................................. 10 PRS LAB S.r.l. Unipersonale Sede operativa e Laboratori di prova Headquarter and Testing lab Via Campagna, 92 I 22020 Faloppio (CO) I Italy Tel. +39 031 3500011 I Fax +39 031 991309 [email protected] I www.primaricerca.it Mod 18_48 rev05 Test Report FCCTR Rapporto di prova - Test report n. FCCTR_181667-0 I Data - Date 28/10/2022 Pagina 3 di 58 0. RELEASE CONTROL RECORD TEST REPORT NUMBER REASON OF CHANGE DATE OF ISSUE FCCTR_181667-0 Original release 28/10/2022 This document is valid in last revision that deletes and replaces the previous one 1. DECISION RULE PRS LAB specifies that, if the decision rules of conformity of the test results are not indicated in detail in the standard/s object of tests, it takes as a decision rule for the declaration of conformity the simple binary system (w = 0) stated in the ILAC-G8-09:2019 document. The decision rule is applicable for all parts of standard Statements of conformity are reported as: - Pass: the measured value is below the acceptance limit, 퐴퐿=푇퐿. - Fail: the measured value is above the acceptance limit, 퐴퐿=푇퐿. Definitions - Guard Band (w): interval between a tolerance limit and a corresponding acceptance limit where length 푤=|푇퐿−퐴퐿|. - Tolerance Limit (TL) (Specification Limit): specified upper or lower bound of permissible values of a property. - Acceptance Limit (AL): specified upper or lower bound of permissible measured quantity values. 2. GENERAL REMARKS • None PRS …
Text truncated - open the document above for the full version.
PRS LAB S.r.l. Unipersonale Sede operativa e Laboratori di prova Headquarter and Testing lab Via Campagna, 92 I 22020 Faloppio (CO) I Italy Tel. +39 031 3500011 I Fax +39 031 991309 [email protected] I www.primaricerca.it Mod 18_48 rev05 Test Report FCCTR Rapporto di prova - Test report n. TSupPhotos_FCC181667-0 I Data - Date 28/10/2022 Pagina 1 di 6 RAPPORTO DI PROVA TEST REPORT Ref. N. TSupPhotos_FCC181667-0 Data Emissione /Issue Date: 28/10/2022 Pagine / Pages: 6 Scopo delle prove Test object Prove di tipo in accordo alla Norme Type test according to Standards 47 CFR FCC part 15 - Subpart C - §15.247 ISED – RSS 247 Richiedente Applicant Italtractor ITM S.p.a. Via confortino 30, 40056 Valsamoggia (BO) loc. Crespellano Marchio commerciale Trade mark Fabbricante Manufacturer Italtractor ITM S.p.a. Via confortino 30, 40056 Valsamoggia (BO) loc. Crespellano Prodotto Product Sensor BLE Modello Model TCKT50050 Identificativo FCC FCC ID 2A845000TCKTX Data ricevimento campioni Date of test samples receipt 30/06/2022 Campioni verificati No. of tested samples 1 – Sampled by the applicant Data verifiche Testing date From 07/07/2022 to 30/08/2022 Sito di prova Testing site PRSLAB S.r.l. Unipersonale - Via Campagna 92 - 22020 Faloppio - Como - Italy Identificativo FCC del sito di prova FCC designation number IT0012 Esito delle valutazioni Assessment results CONFORME / COMPLIANT Verifiche effettuate da Verifications carried out by Daniele AOSANI Tecnico Laboratorio Laboratory Engineer Approvato Approved by Riccardo PFEIFFER Responsabile di Laboratorio Laboratory Manager I risultati delle prove riportati nel presente rapporto di prova si riferiscono solo ai campioni esaminati. The test results reported in this test report shall refer only to the samples tested. Il campione è stato fornito dal cliente ed i risultati si riferiscono al campione così come ricevuto The sample has been provided by the customer and the results apply to the sample as received Questo Report non può essere riprodotto in modo parziale, salvo espressa autorizzazione scritta da parte del Laboratorio This report may not be partially reproduced, except with the prior written permission of the issuing Laboratory PRS LAB S.r.l. Unipersonale Sede operativa e Laboratori di prova - Headquarter and Testing lab: Via Campagna, 92 I 22020 Faloppio (CO) I Italy Tel. +39 031 3500011 I Fax +39 031 991309 [email protected] I www.primaricerca.it Mod 18_48 rev05 Test Report FCCTR Rapporto di prova - Test report n. TSupPhotos_FCC181667-0 I Data - Date 28/10/2022 Pagina 2 di 6 CONTENUTO TABLE OF CONTENTS 0. RELEASE CONTROL RECORD ..................................................................................................... 2 1. TECHNICAL INFORMATION OF EQUIPMENT UNDER TEST (EUT) ................................................. 3 1.1 EUT Identification ......................................................................................................................... 3 1.1 Bluetooth Low Energy module technical data .............................................................................. 4 2. PHOTOGRAPHIC DOCUMENTATION ......................................................................................... 5 0. RELEASE CONTROL RECORD TEST REPORT NUMBER REASON OF CHANGE DATE OF ISSUE TSupPhotos_FCC181667-0 Original release 28/10/2022 This document is valid in last revision that deletes and replaces the previous one PRS LAB S.r.l. Unipersonale Sede operativa e Laboratori di prova - Headquarter and Testing lab: Via Campagna, 92 I 22020 Faloppio (CO) I Italy Tel. +39 031 3500011 I Fax +39 031 991309 [email protected] I www.primaricerca.it Mod 18_48 rev05 Test Report FCCTR Rapporto di prova - Test report n. TSupPhotos_FCC181667-0 I Data - Date 28/10/2022 Pagina 3 di 6 1. TECHNICAL INFORMATION OF EQUIPMENT UNDER TEST (EUT) 1.1 EUT Identification DESCRIPTION Sensor BLE TESTED MODEL TCKT50050 SERIAL NO. Prototype PRS LAB INTERNAL REFERENCE BC 205/2022 2/3 TRADEMARK MANUFACTURER Italtractor ITM S.p.a COUNTRY OF MANUFACTURER Italy SINGLE UNIT OR SYSTEM Single POWER SOURCE Internal battery (CR2450A, Lithium battery) POWER SUPPLY NOMINAL VOLTAGE 3Vdc BATTERY CAPACITY 560mAh OPERATING TEMPERATURE -40°C ÷ +85°C MAX FREQUENCY >1GHz FIRMWARE VERSION (Information provided by Customer) 1.3V DIMENSIONS See photographic section. EUT STANDING Vehicle PRS LAB S.r.l. Unipersonale Sede operativa e Laboratori di prova - Headquarter and Testing lab: Via Campagna, 92 I 22020 Faloppio (CO) I Italy Tel. +39 031 3500011 I Fax +39 031 991309 [email protected] I www.primaricerca.it Mod 18_48 rev05 Test Report FCCTR Rapporto di prova - Test report n. TSupPhotos_FCC181667-0 I Data - Date 28/10/2022 Pagina 4 di 6 1.1 Bluetooth Low Energy module technical data CHIP MANUFACTURER CHIP TYPE nRF52811 ETS CATEGORY Bluetooth Low Energy FREQUENCY BAND Unlicensed 2.4GHz ISM band at 2400-2483.5 MHz NUMBER OF CHANNELS 40 CHANNEL BANDWIDTH 2MHz CHANNEL SEPARATION 2MHz TRANSFER RATE 1Mbps SENSITIVITY -97dBm TYPE OF MODULATION Frequency-shift Keying (FSK) modulation ANTENNA ACAG0301-2450-T ANTENNA GAIN (Information provided by Customer) 5.19dBi ANTENNA TYPE SMD ANTENNA MANUFACTURER 1.1.1 Channel List Bluetooth Low Energy CHANNEL FREQUENCY CHANNEL FREQUENCY CHANNEL FREQUENCY CHANNEL FREQUENCY 0 2402 10 2422 20 2442 30 2462 1 2404 11 2424 21 2444 31 2464 2 2406 12 2426 22 2446 32 2466 3 2408 13 2428 23 2448 33 2468 4 2410 14 2430 24 2450 34 2470 5 2412 15 2432 25 2452 35 2472 6 2414 16 2434 26 2454 36 2474 7 2416 17 2436 27 2456 37 2476 8 2418 18 2438 28 2458 38 2478 9 2420 19 2440 29 2460 39 2480 PRS LAB S.r.l. Unipersonale Sede operativa e Laboratori di prova - Headquarter and Testing lab: Via Campagna, 92 I 22020 Faloppio (CO) I Italy Tel. +39 031 3500011 I Fax +39 031 991309 [email protected] I www.primaricerca.it Mod 18_48 rev05 Test Report FCCTR Rapporto di prova - Test report n. TSupPhotos_FCC181667-0 I Data - Date 28/10/2022 Pagina 5 di 6 2. PHOTOGRAPHIC DOC…
Text truncated - open the document above for the full version.
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 2.40 GHz - 2.48 GHz | 580.00 µW |