Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
=/ 0RGHO=/ &0 : : '&9$ &RORU7HPSHUDWXUH 'HVN/DPS86%&KDUJLQJFDEOH8VHU0DQXDO 7KDQN\RXIRU\RXUSXUFKDVHRIWKLVSURGXFW7KLVPDQXDOGHVFULEHVKRZWRXVH \RXUGHVNODPS%HVXUHWRUHDGLWFDUHIXOO\ ,I\RXKDYHDQ\DGYLFHRQLPSURYLQJWKHSURGXFWSOHDVHVHQGXVPDLO,WZLOOKHOS XVWRGREHWWHULQIXWXUH 'HVN/DPS86%&KDUJLQJFDEOH8VHU0DQXDO $VVHPEOLQJDQG1RWLFH 'RQRWSODFHWKHSURGXFWLQDVORSLQJRUQRQVHFXUHGHVNWRSVRDVQRWWRVOLGHGRZQWKHGDPDJH 'RQRWOHWWKHVXQVKLQHUDLQRUGDPSVRDVQRWWRDIIHFWWKHXVH 'RQRWORRNGLUHFWO\LQWRWKHOLJKWVRXUFHVRDVWRDYRLGH\HGLVFRPIRUW /('OLJKWVRXUFHSURGXFWVFDQQRWEHUHSODFHG 3OHDVHVHOHFWWKHFRUUHFWLQSXWYROWDJHIRUWKHODPS'&9$ 'RQRWGLVDVVHPEOHFKDQJHWKHSURGXFWVWUXFWXUHWRSUHYHQWHOHFWULFVKRFNRUILUHLIWKHSURGXFWLV DEQRUPDOSOHDVHFRQWDFWXV 7RILQGWKHDQJOH\RXQHHGWKHDGMXVWDEOHKHDGFDQURWDWHGHJUHHVOHIWRUULJKWGHJUHHVXSDQGGRZQVR\RXFDQ VKLQHDOLJKWRQDQ\WKLQJ This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: -- Reorient or relocate the receiving antenna. -- Increase the separation between the equipment and receiver. -- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. -- Consult the dealer or an experienced radio/TV technician for help. Warning: changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment Radiation Exposure Statement This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 20cm between the radiator and your body.
C5266091_X8_Ed.1 1/1 LetterofAuthorization ShenZhenShiLingHuiTechnologyCo.Ltd Company:ShenZhenShiLingHuiTechnologyCo.Ltd Address:longgangqushangmugucun2xiang8hao103shenzhen shiguangdong518100 ProductName:desklamp ModelNumber:ZL305 FCCIdentifier:2A87Z-ZL305 WeauthorizeLGAITechnologicalCenterS.A.,RondadelaFontdelCarme,s/n, 08193Bellaterra,Spain,toactonourbehalfonallmattersconcerningthe abovenamedequipment. AnyindividualwithinLGAITechnologicalCenterS.A.isauthorizedtoactonour behalfandtakeactionontheapplication. WedeclarethatauthorizeLGAITechnologicalCenterS.A.,RondadelaFontdel Carme,s/n,08193Bellaterra,Spain,isallowedtoforwardallinformation relatedtotheapprovalprojecttotheFederalCommunicationCommissionand todiscussanyissuesconcerningtheapprovalapplication.Anyandallacts carriedoutbyLGAITechnologicalCenterS.A.onourbehalfshallhavethe sameeffectasactsofourown. Name:YaLiuDate:Nov.022022 Title:Manager Signatureofapplicant:
C5266091_X10_Ed.2 1/1 ShenZhenShiLingHuiTechnologyCo.Ltd OfficeofEngineeringTechnology FederalCommunicationsCommission 7435OaklandMillsRoad Columbia,MD21046 Date:Nov.022022 Subject:RequestforConfidentiality FCCID:2A87Z-ZL305 ToWhomItMayConcern, PursuanttotheprovisionsofSections0.457and0.459ofCommission'srules (47CFR0.457,0.459),wearerequestingtheCommissiontowithholdthefollowing attachment(s)asconfidentialdocumentfrompublicdisclosure. ExhibitsLong-Term Confidentiality Short-Term Confidentiality NOTE2 IDLabel/LocationNoNo AttestationStatementNoNo ExternalPhotosNo ☐ BlockDiagram ☒☐ Schematics ☒☐ TestReportNoNo TestSetupPhotosNo ☐ User’sManual ☐ NOTE 1 ☐ InternalPhotos ☐ NOTE 1 ☐ PartsList/TuneUp ☐☐ RFExposureInfoNoNo OperationalDescription ☒☐ CoverLetter(s)NoNo SDRSoftware/SecurityInfo ☐ No NOTE1:Long-TermConfidentialitymaybepermittedunderspecialconditions(SeeII.LONG-TERMCONFIDENTIALITY,Section3of KDB726920,uselastinforce) NOTE2:Short-TermConfidentialitycanberequestedforamaximumof180daysfromthedateofthegrant. Abovementioneddocumentcontainsdetailedsystemandequipmentdescriptionare consideredasproprietaryinformationinoperationoftheequipment.Thepublic disclosureofabovedocumentsmightbeharmfultoourcompanyandwouldgive competitoranunfairadvantageinthemarket. Incaseofshort-termConfidentiality,theapplicantrequeststheexhibitsselected abovearewithheldfrompublicviewforaperiodof______daysfromthedateofthe GrantofEquipmentAuthorizationandpriortomarketing. Itisourunderstandingthatallmeasurementtestreports,FCCIDlabelformatand correspondentduringcertificationreviewprocesscannotbegrantedasconfidential documentsandthoseinformationwillbeavailableforpublicreviewoncethegrantof equipmentauthorizationisissued. C5266091_X10_Ed.2 1/1 Sincerely, Signature: Name: YaLiu Title:Manager
Page1of3ReportNo.:FCS202210130 Externalphotos Photo1 Photo2 Page2of3ReportNo.:FCS202210130 Photo3 Photo4 Page3of3ReportNo.:FCS202210130 Photo5 Photo6
LabelandLabelLocation FCCID:2A87Z-ZL305
Page3of2ReportNo.:FCS202210130 Photo5 Photo6
Page1of2ReportNo.:FCS202210130 Internalphotos Photo1 Photo2 ANT Page2of2ReportNo.:FCS202210130 Photo3 Photo4
Page1of5ReportNo.:FCS202210130 FluxComplianceServiceLaboratory Room105FloorBaohaoTechnologyBuilding1NO.15GongyeWestRoadHi-TechIndustrial,SongshanlakeDongguan Tel:769-27280901Fax:769-27280901http://www.fcs-lab.com RFExposureEvaluation FCCID:2A87Z-ZL305 1MeasuringStandard KDB680106D01RFExposureWirelessChargingAppsv03r01 2Requirements AccordingtoKDB680106clause5,b Inductivewirelesspowertransferapplicationsthatmeetallofthefollowingrequirementsareexcluded (1)Powertransferfrequencyislessthan1MHz. --Yes,thedeviceoperatedinthefrequencyrangefrom115KHzto205KHz (2)Outputpowerfromeachprimarycoilislessthanorequalto15watts. --Yes,themaximumoutputpoweroftheprimarycoilis5W (3)Thetransfersystemincludesonlysingleprimaryandsecondarycoils.Thisincludescharging systemsthatmayhavemultipleprimarycoilsandclientsthatareabletodetectandallowcouplingonly betweenindividualpairsofcoils. --Yes,thetransfersystemincludesonlysingleprimaryandsecondarycolis (4)Clientdeviceisplaceddirectlyincontactwiththetransmitter. --Yes,Clientdeviceisplaceddirectlyincontactwiththetransmitter (5)Mobileexposureconditionsonly(portableexposureconditionsarenotcoveredbythisexclusion). --Yes (6)TheaggregateH-fieldstrengthsat15cmsurroundingthedeviceand20cmabovethetopsurface fromallsimultaneoustransmittingcoilsaredemonstratedtobelessthan50%oftheMPElimit. --Yes,theEUTfieldstrengthlevelare50%xMPElimit. 3Limits Thecriterialistedinthefollowingtableshallbeusedtoevaluatetheenvironmentimpactofhuman exposuretoradiofrequency(RF)radiationasspecifiedin1.1307(b) LimitsforMaximumPermissibleExposure(MPE) Page2of5ReportNo.:FCS202210130 FluxComplianceServiceLaboratory Room105FloorBaohaoTechnologyBuilding1NO.15GongyeWestRoadHi-TechIndustrial,SongshanlakeDongguan Tel:769-27280901Fax:769-27280901http://www.fcs-lab.com 4TestSetup 5TestProcedure 1)TheRFexposuretestwasperformedinanechoicchamber. 2)Themeasurementprobewasplacedattestdistance(15cmfromallsidesand20cmfrom thetop)whichisbetweentheedgeofthechargerandthegeometriccenterofprobe. 3)Thehighestemissionlevelwasrecordedandcomparedwithlimitassoonasmeasurement ofeachpoints(A,B,C,D,E)werecompleted 4)TheEUTwasmeasuredaccordingtothedictatesofKDB680106D01v03r01 Remark : TheEUT’stestpositionA,B,C,DandEisvalidfortheEandHfieldmeasurements Page3of5ReportNo.:FCS202210130 FluxComplianceServiceLaboratory Room105FloorBaohaoTechnologyBuilding1NO.15GongyeWestRoadHi-TechIndustrial,SongshanlakeDongguan Tel:769-27280901Fax:769-27280901http://www.fcs-lab.com 6Equipmentlist TestEquipmentManufacturerModelNo.SN.Last calibration Calibrated until Electricand Magnetic field probe-Analyzer NardaEHP-200AN03565Feb10,2022Feb09,2023 7Photo Page4of5ReportNo.:FCS202210130 FluxComplianceServiceLaboratory Room105FloorBaohaoTechnologyBuilding1NO.15GongyeWestRoadHi-TechIndustrial,SongshanlakeDongguan Tel:769-27280901Fax:769-27280901http://www.fcs-lab.com 8Testmode Mode1Phone(5W) 9Necessaryaccessories ItemEquipmentMfr/BrandModel/TypeNo.SerialNo.Note 1AdapterHW0789SKN/A Thisadapteris fortestingonlyin report. 2PhoneHWMate20N/A Thisphoneisfor testingonlyin report. 10TestResult Mode1(Worst) E-FiledStrengthat15cmfromtheedgessurroundingtheEUT(V/m) Battery power Frequency Range(MHz) Test Position A Test Position B Test Position C Test Position D Limits (V/m) 1%0.115-0.2051.371.310.530.45614 50%0.115-0.2051.481.230.440.52614 95%0.115-0.2051.311.470.320.53614 Stand-by0.115-0.2051.351.380.540.53614 E-FiledStrengthat20cmfromthetopoftheEUT(V/m) Battery power Frequency Range(MHz) Test PositionE Limits (V/m) 1%0.115-0.2051.22614 50%0.115-0.2051.31614 95%0.115-0.2051.49614 Stand-by0.115-0.2051.55614 H-FiledStrengthat15cmfromtheedgessurroundingtheEUT(A/m) Page5of5ReportNo.:FCS202210130 FluxComplianceServiceLaboratory Room105FloorBaohaoTechnologyBuilding1NO.15GongyeWestRoadHi-TechIndustrial,SongshanlakeDongguan Tel:769-27280901Fax:769-27280901http://www.fcs-lab.com Battery power Frequency Range(MHz) Test Position A Test Position B Test Position C Test Position D Limits (A/m) 1%0.115-0.2050.630.520.710.521.63 50%0.115-0.2050.530.570.570.551.63 95%0.115-0.2050.610.680.510.511.63 Stand-by0.115-0.2050.530.580.640.531.63 H-FiledStrengthat20cmfromthetopoftheEUT(A/m) Battery power Frequency Range(MHz) Test PositionE Limits (A/m) 1%0.115-0.2050.311.63 50%0.115-0.2050.341.63 95%0.115-0.2050.421.63 Stand-by0.115-0.2050.461.63 Testedby:Reviewedby: ※※※※※ENDOFTHEREPORT※※※※※
FCCTestReport ReportNo:FCS202210130W01 Issuedfor Applicant:ShenZhenShiLingHuiTechnologyCo.Ltd Address: longgangqushangmugucun2xiang8hao103shenzhen shiguangdong518100 ProductName:desklamp BrandName:N/A ModelName:ZL305 SeriesModel:N/A FCCID:2A87Z-ZL305 IssuedBy:FluxComplianceServiceLaboratory Add:Room105FloorBaohaoTechnologyBuilding1NO.15GongyeWestRoadHi-Tech Industrial,SongshanlakeDongguan Tel:769-27280901Fax:769-27280901http://www.fcs-lab.com Page2of24ReportNo.:FCS202210130W01 FluxComplianceServiceLaboratory Room105FloorBaohaoTechnologyBuilding1NO.15GongyeWestRoadHi-TechIndustrial,SongshanlakeDongguan Tel:769-27280901Fax:769-27280901http://www.fcs-lab.com TESTRESULTCERTIFICATION Applicant’sName......................:ShenZhenShiLingHuiTechnologyCo.Ltd Address......................................: longgangqushangmugucun2xiang8hao103shenzhen shiguangdong518100 Manufacture'sName ................ :ShenZhenShiLingHuiTechnologyCo.Ltd Address......................................: longgangqushangmugucun2xiang8hao103shenzhen shiguangdong518100 ProductDescription ProductName ........................... :desklamp BrandName ............................. :N/A ModelName..............................:ZL305 SeriesModel..............................:N/A TestStandards..........................:FCCRulesandRegulationsPart15SubpartC,Section209 TestProcedure .......................... :ANSIC63.10:2013 ThisdevicedescribedabovehasbeentestedFCS,thetestresultsshowthattheequipmentunder test(EUT)isincompliancewiththeFCCrequirements.Anditisapplicableonlytothetestedsample identifiedinthereport. Thisreportshallnotbereproducedexceptinfull,withoutthewrittenapprovalofFCS,thisdocument maybealteredorrevisedbyFCS,personalonly,andshallbenotedintherevisionofthedocument.. DateofTest .................................. : Date(s)ofperformanceoftests.:23Oct.2022~26Oct.2022 DateofIssue.................................:26Oct.2022 TestResult.....................................:Pass Testedby: (ScottShen) Reviewedby : (DukeQian) Approvedby: (JackWang) Page3of24ReportNo.:FCS202210130W01 FluxComplianceServiceLaboratory Room105FloorBaohaoTechnologyBuilding1NO.15GongyeWestRoadHi-TechIndustrial,SongshanlakeDongguan Tel:769-27280901Fax:769-27280901http://www.fcs-lab.com TableofContentsPage 1.SUMMARYOFTESTRESULTS..............................................................................................5 1.1TESTFACTORY................................................................................................................6 1.2MEASUREMENTUNCERTAINTY.....................................................................................6 2.GENERALINFORMATION.......................................................................................................7 2.1GENERALDESCRIPTIONOFTHEEUT..........................................................................7 2.2DESCRIPTIONOFTHETESTMODES............................................................................8 2.3DESCRIPTIONOFNECESSARYACCESSORIESANDSUPPORTUNITS..................9 2.4EQUIPMENTSLIST.........................................................................................................10 3CONDUCTEDEMISSIONMEASUREMENT..........................................................................11 3.1LIMIT.................................................................................................................................11 3.2TESTPROCEDURE........................................................................................................11 3.3TESTSETUP...................................................................................................................12 3.4TESTRESULTS...............................................................................................................13 4.RADIATEDEMISSIONMEASUREMENT..............................................................................15 4.1LIMIT................................................................................................................................15 4.2TESTPROCEDURE........................................................................................................16 4.3TESTSETUP...................................................................................................................17 4.4TESTRESULTS...............................................................................................................18 5.20DBBANDWIDTHTEST.....................................................................................................22 5.1LIMIT................................................................................................................................22 5.2TESTPROCEDURE........................................................................................................22 5.3TESTSETUP...................................................................................................................22 5.4TESTRESULTS...............................................................................................................23 6.ANTENNAREQUIREMENT...................................................................................................24 6.1STANDARDREQUIREMENT..........................................................................................24 6.2EUTANTENNA................................................................................................................24 Page4of24ReportNo.:FCS202210130W01 FluxComplianceServiceLaboratory Room105FloorBaohaoTechnologyBuilding1NO.15GongyeWestRoadHi-TechIndustrial,SongshanlakeDongguan Tel:769-27280901Fax:769-27280901http://www.fcs-lab.com RevisionHistory Rev.IssueDateEffectPageContents 0026Oct.2022AllInitialIssue Page5of24ReportNo.:FCS202210130W01 FluxComplianceServiceLaboratory Room105FloorBaohaoTechnologyBuilding1NO.15GongyeWestRoadHi-TechIndustrial,SongshanlakeDongguan Tel:769-27280901Fax:769-27280901http://www.fcs-lab.com 1.SUMMARYOFTESTRESULTS FCCRulesandRegulationsPart15Subpar…
Text truncated - open the document above for the full version.
客戶 CUSTOMER龙梓芯 客戶品名料號 CURS.PARTNAME. PARTNO. 本公司品名 無線充發射線圈 料號 OURSPARTNAME.A11G50-6R3M雙槽帶孔 PARTNO.19004 工程出圖 ENGINEERINGDRAWING 發行 MADE 檢查 CHECKED 承認 APPROVED 陳後強何雲成胡志強 承認印 CUSTOMERAPPROVE 承認書番 SPECNO.ZXY-LZX-19004 承認書 SPECIFICATIONFORAPPROVAL 日期 DATE:2019年04月02日 Page:2/3 仕樣書變更履歷表 SPECIFICATIONALTERATIONHISTORY RECORDS 仕樣書番號 SPECNO: ZXY-LZX-19004 No. DATE 變更內容及理由 Alterationcontentsandreason 確認印 Confirm No.1 2019年04月02日 第一次制定胡志強 No.2 胡志強 No.3 印 No.4 印 No.5 印 No.6 印 No.7 印 No.8 印 No.9 印 No.11 印 ZHIXIANGYUANGELECTRONICIND.CO.,LTD. 表單編號/版本:QR-009/A ProductNumber: ProductDescriptionPowerInductor(verticalMount) 1.MECHANICALDIMENSIONS: ( mm ) 2.SCHEMATIC: 3.ELECTRICALCHARACTERISTICS: 3.1INDUCTANCE@100KHz,/1V,25 °C Inductance:6.3 u H ±1 0%.WITHDCBIAS0A. DCR:47m Ω MAX. MaxCurrent:1.0A 3.2TESTINTRUMENTS:&Chroma3302&Chroma1320; &Chroma16502;CALLIPERS. 3.2MATERIALLIST 4.包裝方式: (1) 每 400PCS 裝入 1 盒珍珠棉孔 . (2)每1600PCS裝入1箱紙箱內. (3)每箱需貼上客戶指定的物料標籤. A43.0 ± 1.5 B20.5±0.5 C1.0±0.2 D152 ± 2 D250±2 E3.0 ± 1.0 F50.0±1.0 G5.3ref H2.6Max NO.PARTNAMEDISCRIPTIONSUPPLIERREMARK 1磁片PC44φ50*1.0UNITEDN/A 2絲包線0.08mmx105太平洋E201757 3膠水778 4高溫膠帶0.06mm*8mm SPECNO: PARTNAME.:A11G50-6R3M雙槽帶孔 PAGE:3/3
Page 1 of2ReportNo.:FCS202210130 Blow1GHzforradiatedemissiontestsetup Page 2 of2ReportNo.:FCS202210130 CE
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 0.115 MHz - 0.205 MHz | - |