FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. GLOBAL TEST SUPPLY LLC./
  3. 2A8GT-R1640

2A8GT-R1640Thermocouple Thermometer

GLOBAL TEST SUPPLY LLC.
Thermocouple Thermometer - FCC ID 2A8GT-R1640 - GLOBAL TEST SUPPLY LLC.
Click to zoom

Application Details

Equipment Class
DTS - Digital Transmission System
Date of Grant
Jan 10, 2023
Application Purpose
Original Equipment
Date of Application
Jan 10, 2023
Equipment Note
Thermocouple Thermometer
Frequency Range
2402.00000000 - 2480.00000000
Company
GLOBAL TEST SUPPLY LLC.
Country
United States

Documents & Files

Select a file to view

Users Manual

↗

Cover Letter(s)

↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗
↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

www.REEDInstruments.com Instruction Manual R1640 Thermocouple Thermometer W A R R A N T Y W A R R A N T Y 1 YEAR 1 AN G A R A N T I E G A R A N T I E W A R R A N T Y W A R R A N T Y G A R A N T I E G A R A N T I E W A R R A N T Y W A R R A N T Y G A R A N T I E G A R A N T I E White background Transparent background White Black 1 YEAR1 AN R1640-PRINT.indd 1R1640-PRINT.indd 12022-12-02 10:36 AM2022-12-02 10:36 AM www.REEDInstruments.com Manuel d’utilisation R1640 W A R R A N T Y W A R R A N T Y 1 YEAR 1 AN G A R A N T I E G A R A N T I E W A R R A N T Y W A R R A N T Y G A R A N T I E G A R A N T I E W A R R A N T Y W A R R A N T Y G A R A N T I E G A R A N T I E White background Transparent background White Black 1 YEAR1 AN Thermomètre à thermocouple R1640-PRINT.indd 1R1640-PRINT.indd 12022-12-02 10:36 AM2022-12-02 10:36 AM R1640-Imposition.indd 1R1640-Imposition.indd 12022-12-02 10:42 AM2022-12-02 10:42 AM 2 www.REEDInstruments.com Table of Contents Introduction .................................................................................................3 Product Quality ............................................................................................3 Safety ..........................................................................................................3 Features .......................................................................................................4 Included .......................................................................................................4 Specification .......................................................................................... 5-6 FCC Compliance Statement .......................................................................6 ISED Regulatory Compliance Statement ....................................................6 Instrument Description ................................................................................7 Display Description .....................................................................................8 REED Smart Series App ..............................................................................9 App Features ....................................................................................... 9 Operating Instructions ..........................................................................10-11 Power ON/OFF .................................................................................. 10 Backlight ........................................................................................... 10 Establishing Bluetooth ® Connection ................................................ 10 Connecting Thermocouples .............................................................. 10 Measuring Temperature Procedure .................................................. 11 Enabling/Disabling Data Hold ............................................................ 11 Enabling/Disabling Auto Power OFF ................................................. 11 Battery Replacement .................................................................................12 Applications ...............................................................................................12 Accessories and Replacement Parts ........................................................13 Product Care .............................................................................................13 Product Warranty ......................................................................................14 Product Disposal and Recycling ...............................................................14 Product Support ........................................................................................14 continued... R1640-PRINT.indd 2R1640-PRINT.indd 22022-12-02 10:36 AM2022-12-02 10:36 AM 2 www.REEDInstruments.com Table des matières Introduction ................................................................................................ 3 Qualité du produit ....................................................................................... 3 Sécurité ...................................................................................................... 3 Caractéristiques ......................................................................................... 4 Comprend .................................................................................................. 4 Spécification ..........................................................................................5-6 Déclaration de conformité de la FCC ......................................................... 6 Déclaration de conformité de la ISDE ........................................................ 6 Description de l'instrument ........................................................................ 7 Description de l'affichag ........................................................................... 8 Application REED Smart Series ................................................................. 9 Caractéristiques de l’application ............................................................ 9 Mode d'emploi ....................................................................................10-11 Marche/Arrêt ........................................................................................ 10 Rétroéclairage ...................................................................................... 10 Établissement de la connexion Bluetooth MD ........................................ 10 Connexion des thermocouples ............................................................ 10 Procédure de mesure de la température ............................................. 11 Activation/désactivation de la fonction de maintien des données ....... 11 Activer/désactiver la mise hors tension automatique........................... 12 Remplacement des piles .......................................................................... 12 Applications ....................................…

Text truncated - open the document above for the full version.

Cover Letter(s)

SCS-F019: Confidentiality Request Letter Page 1 of 2 Rev 7.0 775 Montague Expressway Milpitas, CA 95035 Tel: 408-526-1188 Fax: 408-526-1088 Email: [email protected] W ebsite: https://www.cps.bureauveritas.com/ Confidentiality Request Letter Reason for Amendment (current / obsolete) Revision History Approved Date From To Initial Release (obsolete) 1.0 1.0 Nov-14-2006 Adding CFR 2.459 (obsolete) 1.0 2.0 August – 11 - 2008 Updated company template & Added text box (obsolete) 2.0 3.0 Jan-31-2012 Added IC confidentiality letter form (obsolete) 3.0 4.0 March-26-2015 Corrections to STC form. Added reference to KDB (obsolete) 4.0 5.0 Nov-19-2015 Updated company logo (current) 5.0 6.0 Jun-26-2019 Updated References and Contact Info 6.0 7.0 Aug-30-2020 SCS-F019: Confidentiality Request Letter Page 2 of 2 Rev 7.0 GLOBAL TEST SUPPLY LLC. 2023.1.4 To: Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046-1609 Cc: Bureau Veritas Consumer Products Services Inc. 775 Montague Expressway Milpitas, CA 95035 Subject: Confidentiality Request for FCC ID: 2A8GT-R1640 Pursuant to CFR 47 sections 0.457 and 0.459, we respectfully request permanent confidential treatment of the following Exhibits accompanying this application be held confidential: Type of Confidentiality Requested Exhibit Short Term Permanent Block Diagram Short Term External Photos Short Term Permanent i Internal Photos Short Term Permanent Operational Description/ Theory of Operation Short Term Permanent Parts List Short Term Permanent Tune-Up Procedure Short Term Permanent Schematics Short Term Test Setup Photos Short Term Permanent i User’s Manual The above materials contain trade secrets and proprietary information not customarily released to the public. The public disclosure of these materials may be harmful to the applicant and provide unjustified benefits to its competitors. Permanent Confidentiality: The applicant requests the exhibits listed above as permanently confidential be permanently withheld from public review due to materials that contain trade secrets and proprietary information not customarily released to the public. Short-Term Confidentiality: To avoid premature release of sensitive information prior to marketing or release of the product to the public, the applicant requests the following documents contained in this certification application be temporarily withheld from public disclosure for an initial period of 45 or 180 days; or for a specified date of not to exceed 180 days from the Grant Date The applicant understands that disclosure of this application and all accompanying documentation will not be made before the date of the Grant for this application. Sincerely, Client’s signature Client’s name: Chris Korres Title : Business Development Manager Contact information / address : 312 Raleigh Street, Suite 9 Wilmington, NC 28412 Permanent confidentiality may be requested in accordance with FCC KDB 726920

External Photos

Bureau Veritas Shenzhen Co., Ltd. Dongguan Branch No. 96, Guantai Road (Houjie Section), Houjie Town, Dongguan City, Guangdong Province. 523942. People’s Republic of China. Tel.: +86 769 8998 2098 Fax: +86 769 8593 1080 Email: [email protected] Page 1 of 4 Report Version A Reference No.: 2210WDG0058 PHOTOGRAPHS OF THE EUT Bureau Veritas Shenzhen Co., Ltd. Dongguan Branch No. 96, Guantai Road (Houjie Section), Houjie Town, Dongguan City, Guangdong Province. 523942. People’s Republic of China. Tel.: +86 769 8998 2098 Fax: +86 769 8593 1080 Email: [email protected] Page 2 of 4 Report Version A Reference No.: 2210WDG0058 Bureau Veritas Shenzhen Co., Ltd. Dongguan Branch No. 96, Guantai Road (Houjie Section), Houjie Town, Dongguan City, Guangdong Province. 523942. People’s Republic of China. Tel.: +86 769 8998 2098 Fax: +86 769 8593 1080 Email: [email protected] Page 3 of 4 Report Version A Reference No.: 2210WDG0058 Bureau Veritas Shenzhen Co., Ltd. Dongguan Branch No. 96, Guantai Road (Houjie Section), Houjie Town, Dongguan City, Guangdong Province. 523942. People’s Republic of China. Tel.: +86 769 8998 2098 Fax: +86 769 8593 1080 Email: [email protected] Page 4 of 4 Report Version A Reference No.: 2210WDG0058

Internal Photos

Bureau Veritas Shenzhen Co., Ltd. Dongguan Branch No. 96, Guantai Road (Houjie Section), Houjie Town, Dongguan City, Guangdong Province. 523942. People’s Republic of China. Tel.: +86 769 8998 2098 Fax: +86 769 8593 1080 Email: [email protected] Page 1 of 5 Report Version A Reference No.: 2210WDG0058 PHOTOGRAPHS OF THE EUT Bureau Veritas Shenzhen Co., Ltd. Dongguan Branch No. 96, Guantai Road (Houjie Section), Houjie Town, Dongguan City, Guangdong Province. 523942. People’s Republic of China. Tel.: +86 769 8998 2098 Fax: +86 769 8593 1080 Email: [email protected] Page 2 of 5 Report Version A Reference No.: 2210WDG0058 Bureau Veritas Shenzhen Co., Ltd. Dongguan Branch No. 96, Guantai Road (Houjie Section), Houjie Town, Dongguan City, Guangdong Province. 523942. People’s Republic of China. Tel.: +86 769 8998 2098 Fax: +86 769 8593 1080 Email: [email protected] Page 3 of 5 Report Version A Reference No.: 2210WDG0058 Bureau Veritas Shenzhen Co., Ltd. Dongguan Branch No. 96, Guantai Road (Houjie Section), Houjie Town, Dongguan City, Guangdong Province. 523942. People’s Republic of China. Tel.: +86 769 8998 2098 Fax: +86 769 8593 1080 Email: [email protected] Page 4 of 5 Report Version A Reference No.: 2210WDG0058 Bureau Veritas Shenzhen Co., Ltd. Dongguan Branch No. 96, Guantai Road (Houjie Section), Houjie Town, Dongguan City, Guangdong Province. 523942. People’s Republic of China. Tel.: +86 769 8998 2098 Fax: +86 769 8593 1080 Email: [email protected] Page 5 of 5 Report Version A Reference No.: 2210WDG0058 BT ANT

RF Exposure Info

Bureau Veritas Shenzhen Co., Ltd. Dongguan Branch No. 96, Guantai Road (Houjie Section), Houjie Town, Dongguan City, Guangdong Province. 523942. People’s Republic of China. Tel: +86 769 8998 2098 Fax: +86 769 8593 1080 Email: [email protected] Page 1 of 6 Report Version A Test Report No.: FM2210WDG0058 RF EXPOSURE REPORT Applicant GLOBAL TEST SUPPLY LLC. Address 312 Raleigh Street, Suite 9 Wilmington, NC 28412 Manufacturer or Supplier Shenzhen Everbest Machinery Industry Co., Ltd Address 19th Building, 5th Region, Baiwangxin Industrial Park, SongBai Rd., Baimang, Xili, Nanshan, Shenzhen China Product Thermocouple Thermometer Brand Name REED Instruments Model R1640 Additional Model & Model Difference N/A Date of tests Nov. 18, 2022 ~ Nov. 28, 2022 FCC Part 2 (Section 2.1093) KDB 447498 D01 IEEE C95.1 CONCLUSION: The submitted sample was found to COMPLY with the test requirement Tested by Andy Zhu Supervisor / EMC Department Approved by Glyn He Assistant Manager / EMC Department Date: Dec. 28, 2022 This report is governed by, and incorporates by reference, the Conditions of Testing as posted at the date of issuance of this report at http://www.bureauveritas.com/home/about-us/our-business/cps/about-us/terms-conditions/ and is intended for your exclusive use. Any copying or replication of this report to or for any other person or entity, or use of our name or trademark, is permitted only with our prior written permission. This report sets forth our findings solely with respect to the test samples identified herein. The results set forth in this report are not indicative or representative of the quality or characteristics of the lot from which a test sample was taken or any similar or identical product unless specifically and expressly noted. Our report includes all of the tests requested by you and the results thereof based upon the information that you provided to us. Measurement uncertainty is only provided upon request for accredited tests. Statements of conformity are based on simple acceptance criteria without taking measurement uncertainty into account, unless otherwise requested in writing. You have 60 days from date of issuance of this report to notify us of any material error or omission caused by our negligence or if you require measurement uncertainty; provided, however, that such notice shall be in writing and shall specifically address the issue you wish to raise. A failure to raise such issue within the prescribed time shall constitute your unqualified acceptance of the completeness of this report, the tests conducted and the correctness of the report contents.. Bureau Veritas Shenzhen Co., Ltd. Dongguan Branch No. 96, Guantai Road (Houjie Section), Houjie Town, Dongguan City, Guangdong Province. 523942. People’s Republic of China. Tel: +86 769 8998 2098 Fax: +86 769 8593 1080 Email: [email protected] Page 2 of 6 Report Version A Test Report No.: FM2210WDG0058 TABLE OF CONTENTS RELEASE CONTROL RECORD ................................................................................ 3 1. CERTIFICATION .............................................................................................. 4 2. RF EXPOSURE DEFINE ................................................................................. 5 3. CLASSIFICATION ........................................................................................... 5 4. SAR TEST EXCLUSION THRESHOLDS ........................................................ 6 Bureau Veritas Shenzhen Co., Ltd. Dongguan Branch No. 96, Guantai Road (Houjie Section), Houjie Town, Dongguan City, Guangdong Province. 523942. People’s Republic of China. Tel: +86 769 8998 2098 Fax: +86 769 8593 1080 Email: [email protected] Page 3 of 6 Report Version A Test Report No.: FM2210WDG0058 RELEASE CONTROL RECORD ISSUE NO. REASON FOR CHANGE DATE ISSUED FM2210WDG0058 Original release Dec. 28, 2022 Bureau Veritas Shenzhen Co., Ltd. Dongguan Branch No. 96, Guantai Road (Houjie Section), Houjie Town, Dongguan City, Guangdong Province. 523942. People’s Republic of China. Tel: +86 769 8998 2098 Fax: +86 769 8593 1080 Email: [email protected] Page 4 of 6 Report Version A Test Report No.: FM2210WDG0058 1. CERTIFICATION FCC ID: 2A8GT-R1640 PRODUCT: Thermocouple Thermometer BRAND NAME: REED Instruments MODEL NO.: R1640 ADDITIONAL NO.: N/A APPLICANT: GLOBAL TEST SUPPLY LLC. STANDARDS: FCC Part 2 (Section 2.1093) KDB 447498 D01 IEEE C95.1 Bureau Veritas Shenzhen Co., Ltd. Dongguan Branch No. 96, Guantai Road (Houjie Section), Houjie Town, Dongguan City, Guangdong Province. 523942. People’s Republic of China. Tel: +86 769 8998 2098 Fax: +86 769 8593 1080 Email: [email protected] Page 5 of 6 Report Version A Test Report No.: FM2210WDG0058 2. RF EXPOSURE DEFINE The corresponding SAR Exclusion Threshold condition, listed below: 1) The 1-g and 10-g SAR test exclusion thresholds for 100 MHz to 6 GHz at test separation distances ≤ 50 mm are determined by: [(max. power of channel, including tune-up tolerance, mW)/(min. test separation distance, mm)] ·[ √f(GHz)] ≤ 3.0 for 1-g SAR and ≤ 7.5 for 10-g extremity SAR,16 where  ï‚· f(GHz) is the RF channel transmit frequency in GHz  ï‚· Power and distance are rounded to the nearest mW and mm before calculation  ï‚· The result is rounded to one decimal place for comparison The test exclusions are applicable only when the minimum test separation distance is ≤ 50 mm and for transmission frequencies between 100 MHz and 6 GHz. When the minimum test separation distance is < 5 mm, a distance of 5 mm is applied to determine SAR test exclusion. 2) At 100 MHz to 6 GHz and for test separation distances > 50 mm, the SAR test exclusion threshold is determined according to the following: a) [Threshold at 50 mm in step 1) + (test separation distance - 50 mm)·( f(MHz)/150)] mW, at 100MHz to 1500 MHz b) [Threshold at 50 mm in step 1) + (test separation distance - 50 mm)·10] m…

Text truncated - open the document above for the full version.

Test Report

Bureau Veritas Shenzhen Co., Ltd. Dongguan Branch No. 96, Guantai Road (Houjie Section), Houjie Town, Dongguan City, Guangdong Province. 523942. People’s Republic of China. Tel: +86 769 8998 2098 Fax: +86 769 8593 1080 Email: [email protected] Page 1 of 44 Report Version A Test Report No.: RF2210WDG0058 TEST REPORT Applicant GLOBAL TEST SUPPLY LLC. Address 312 Raleigh Street, Suite 9 Wilmington, NC 28412 Manufacturer or Supplier Shenzhen Everbest Machinery Industry Co., Ltd Address 19th Building, 5th Region, Baiwangxin Industrial Park, SongBai Rd., Baimang, Xili, Nanshan, Shenzhen China Product Thermocouple Thermometer Brand Name REED Instruments Model R1640 Additional Model & Model Difference N/A Date of tests Nov. 18, 2022 ~ Nov. 28, 2022 the tests have been carried out according to the requirements of the following standard: FCC Part 15, Subpart C, Section 15.247 CONCLUSION: The submitted sample was found to COMPLY with the test requirement Tested by Andy Zhu Supervisor / EMC Department Approved by Glyn He Assistant Manager / EMC Department Date: Dec. 28, 2022 This report is governed by, and incorporates by reference, the Conditions of Testing as posted at the date of issuance of this report at http://www.bureauveritas.com/home/about-us/our-business/cps/about-us/terms-conditions/ and is intended for your exclusive use. Any copying or replication of this report to or for any other person or entity, or use of our name or trademark, is permitted only with our prior written permission. This report sets forth our findings solely with respect to the test samples identified herein. The results set forth in this report are not indicative or representative of the quality or characteristics of the lot from which a test sample was taken or any similar or identical product unless specifically and expressly noted. Our report includes all of the tests requested by you and the results thereof based upon the information that you provided to us. Measurement uncertainty is only provided upon request for accredited tests. Statements of conformity are based on simple acceptance criteria without taking measurement uncertainty into account, unless otherwise requested in writing. You have 60 days from date of issuance of this report to notify us of any material error or omission caused by our negligence or if you require measurement uncertainty; provided, however, that such notice shall be in writing and shall specifically address the issue you wish to raise. A failure to raise such issue within the prescribed time shall constitute your unqualified acceptance of the completeness of this report, the tests conducted and the correctness of the report contents. Bureau Veritas Shenzhen Co., Ltd. Dongguan Branch No. 96, Guantai Road (Houjie Section), Houjie Town, Dongguan City, Guangdong Province. 523942. People’s Republic of China. Tel: +86 769 8998 2098 Fax: +86 769 8593 1080 Email: [email protected] Page 2 of 44 Report Version A Test Report No.: RF2210WDG0058 TABLE OF CONTENTS RELEASE CONTROL RECORD ............................................................................................................ 4 1 SUMMARY OF TEST RESULTS .................................................................................................... 5 2 MEASUREMENT UNCERTAINTY ................................................................................................. 5 3 GENERAL INFORMATION ............................................................................................................ 6 3.1 GENERAL DESCRIPTION OF EUT............................................................................................. 6 3.2 DESCRIPTION OF TEST MODES............................................................................................... 7 3.2.1. CONFIGURATION OF SYSTEM UNDER TEST ............................................................... 7 3.2.2. TEST MODE APPLICABILITY AND TESTED CHANNEL DETAIL .................................... 7 3.3 GENERAL DESCRIPTION OF APPLIED STANDARDS .............................................................. 9 3.4 DESCRIPTION OF SUPPORT UNITS ......................................................................................... 9 3.5 CONFIGURATION OF SYSTEM UNDER TEST .......................................................................... 9 4 TEST TYPES AND RESULTS ...................................................................................................... 10 4.1 RADIATED EMISSION MEASUREMENT .................................................................................. 10 4.1.1 LIMITS OF RADIATED EMISSION MEASUREMENT .................................................... 10 4.1.2 TEST INSTRUMENTS ...................................................................................................... 11 4.1.3 TEST PROCEDURES ..................................................................................................... 12 4.1.4 DEVIATION FROM TEST STANDARD ........................................................................... 13 4.1.5 TEST SETUP ................................................................................................................... 13 4.1.6 EUT OPERATING CONDITIONS .................................................................................... 14 4.1.7 TEST RESULTS .............................................................................................................. 15 4.2 6DB BANDWIDTH MEASUREMENT ......................................................................................... 23 4.2.1 LIMITS OF 6DB BANDWIDTH MEASUREMENT ........................................................... 23 4.2.2 TEST INSTRUMENTS ..................................................................................................... 23 4.2.3 TEST PROCEDURE ........................................................................................................ 24 4.2.4 DEVIATION FROM TEST S…

Text truncated - open the document above for the full version.

Test Report

NOTE:ThisdocumentisissuedbyShenzhenMorlabCommunicationsTechnologyCo.,Ltd.,thetestreportshallnotbereproducedexceptin fullwithoutpriorwrittenpermissionofthecompany.Thetestresultsapplyonlytotheparticularsample(s)testedandtothespecifictestscarried outwhichisavailableonrequestforvalidationandinformationconfirmedatourwebsite. MORLAB ShenzhenMorlabCommunicationsTechnologyCo.,Ltd.,FL1-3,BuildingA, FeiYangSciencePark,No.8LongChangRoad,Block67,BaoAnDistrict, ShenZhen,GuangDongProvince,P.R.China Tel:86-755-36698555Fax:86-755-36698525 Http://www.morlab.cnE-mail:[email protected] Page1of 14 REPORTNo.:SZ22110117E01 TESTREPORT APPLICANT:ZhejiangLierdaInternetofThingsTechnologyCo.,Ltd PRODUCTNAME:T55BLEModule MODELNAME:LSD4BT-T55ASTD001 TRADENAME:Lierda BRANDNAME:N/A STANDARD(S):IEEEStd149-2021 RECEIPTDATE:2022-11-10 TESTDATE:2022-11-10 ISSUEDATE:2022-11-22 Editedby: FangJinshan(Rapporteur) Approvedby: ChiShide(Supervisor) MORLAB ShenzhenMorlabCommunicationsTechnologyCo.,Ltd.FL1-3,BuildingA, FeiYangSciencePark,No.8LongChangRoad,Block67,BaoAnDistrict, ShenZhen,GuangDongProvince,P.R.China Tel:86-755-36698555Fax:86-755-36698525 Http://www.morlab.cnE-mail:[email protected] Page2of14 REPORTNo.:SZ22110117E01 DIRECTORY 1.TechnicalInformation ........................................................................................................3 1.1.ApplicantandManufacturerInformation ....................................................................3 1.2.EquipmentUnderTest(EUT)Description...................................................................3 2.TestResults........................................................................................................................4 2.1.AppliedReferenceDocuments.....................................................................................4 2.2.TestConditions...............................................................................................................4 2.3.MeasurementUncertainty.............................................................................................4 2.4.TestResultslists.............................................................................................................5 AnnexAPhotographs...........................................................................................................6 AnnexBFigures .....................................................................................................................7 1.2DRadiationPattern .........................................................................................................7 2.3DRadiationPattern .........................................................................................................8 AnnexCPhotographs .........................................................................................................12 AnnexDGeneralInformation .............................................................................................14 1.1IdentificationoftheResponsibleTestingLaboratory..............................................14 1.2IdentificationoftheResponsibleTestingLocation..................................................14 1.3TestEquipmentsUtilized..............................................................................................14 ChangeHistory VersionDateReasonforchange 1.02022-11-22Firstedition MORLAB ShenzhenMorlabCommunicationsTechnologyCo.,Ltd.FL1-3,BuildingA, FeiYangSciencePark,No.8LongChangRoad,Block67,BaoAnDistrict, ShenZhen,GuangDongProvince,P.R.China Tel:86-755-36698555Fax:86-755-36698525 Http://www.morlab.cnE-mail:[email protected] Page3of14 REPORTNo.:SZ22110117E01 1.TechnicalInformation Note:Providebymanufacturer. 1.1.ApplicantandManufacturerInformation Applicant: ZhejiangLierdaInternetofThingsTechnologyCo.,Ltd ApplicantAddress: Room1402,building1,No.1326,WenyiWestRoad,Cangqian street,YuhangDistrict,Hangzhou,Zhejiang Manufacturer:ZhejiangLierdaInternetofThingsTechnologyCo.,Ltd ManufacturerAddress:Room1402,building1,No.1326,WenyiWestRoad,Cangqian street,YuhangDistrict,Hangzhou,Zhejiang 1.2.EquipmentUnderTest(EUT)Description WirelessTypeBluetooth FrequencyN/A IMEIN/A SampleNo.1# MORLAB ShenzhenMorlabCommunicationsTechnologyCo.,Ltd.FL1-3,BuildingA, FeiYangSciencePark,No.8LongChangRoad,Block67,BaoAnDistrict, ShenZhen,GuangDongProvince,P.R.China Tel:86-755-36698555Fax:86-755-36698525 Http://www.morlab.cnE-mail:[email protected] Page4of14 REPORTNo.:SZ22110117E01 2.TestResults 2.1.AppliedReferenceDocuments Leadingreferencedocumentsfortesting: No.IdentityDocumentTitle 1 IEEEStd149-2021 IEEERecommendedPracticeforAntenna Measurements 2.2.TestConditions TestEnvironmentConditions : RelativeHumidity:25...75% Temperature:+10°Cto+30°C 2.3.MeasurementUncertainty Theuncertaintyiscalculatedusingthemethodssuggestedinthe"GuidetotheExpressionof UncertaintyinMeasurement"(GUM)publishedbyISO.Whenthetestresultisacriticalvalue,we willusethemeasurementuncertaintygivethejudgmentresultbasedonthe95%Confidence intervals. ItemMeasurementUncertainty(dB) Gain±0.5 VSWR±0.2 MeasurementUncertainty(95%ConfidenceInterval)K=2 MORLAB ShenzhenMorlabCommunicationsTechnologyCo.,Ltd.FL1-3,BuildingA, FeiYangSciencePark,No.8LongChangRoad,Block67,BaoAnDistrict, ShenZhen,GuangDongProvince,P.R.China Tel:86-755-36698555Fax:86-755-36698525 Http://www.morlab.cnE-mail:[email protected] Page5of14 REPORTNo.:SZ22110117E01 2.4.TestResultslists 2.4.1.GainandEfficiency Frequency(MHz)Efficiency(%)Gain(dBi) 24008.98-5.12 24109.43-4.99 24209.79-4.80 243010.36-4.48 244011.11-4.12 245012.00-3.79 246012.64-3.74 247012.89-3.71 248013.19-3.51 249013.15-3.40 250013.58-3.13 2.4.2.VSWRandImpedance FrequencyVSWR Impedance (Ω) 2400MHz4.0588.41 2440MHz 2.68132.12 2480MHz1.7350.37 2.4.3.ReturnLoss Frequency ReturnLoss (dB) 2400MHz-4.36 2440MHz -6.79 2480MHz-11.38 MORLAB ShenzhenMorlabCommunicationsTechnologyCo.,Ltd.FL1-3,BuildingA, FeiYangSciencePark,No.8LongChangRoad,Block67,BaoAnDistrict, ShenZhen,GuangDongProvince,P.R.China Tel:86-755-36698555Fax:86-755-366…

Text truncated - open the document above for the full version.

Test Setup Photos

Bureau Veritas Shenzhen Co., Ltd. Dongguan Branch No. 96, Guantai Road (Ho…

Text truncated - open the document above for the full version.

Contact Information

Applicant

Chris Korres(Business Development Manager)
[email protected]877-849-2127Fax: 514-457-7280

Test Firm

Bureau Veritas Shenzhen Co., Ltd. Dongguan BranchEdwin Ye
[email protected]86-20-8714 8549

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.40 GHz - 2.48 GHz4.26 mW
Confidentiality
Long Term
Grant Notes
Power listed is the maximum conducted output power.

Other Applications from GLOBAL TEST SUPPLY LLC.

Light Meter - FCC ID 2A8GT-R1630 - GLOBAL TEST SUPPLY LLC.
2A8GT-R1630

Light Meter

Jan 10, 2023

Equipment Class

DTS - Digital Transmission System
Sound Level Meter - FCC ID 2A8GT-R1620 - GLOBAL TEST SUPPLY LLC.
2A8GT-R1620

Sound Level Meter

Jan 10, 2023

Equipment Class

DTS - Digital Transmission System
Vane Anemometer - FCC ID 2A8GT-R1600 - GLOBAL TEST SUPPLY LLC.
2A8GT-R1600

Vane Anemometer

Jan 09, 2023

Equipment Class

DTS - Digital Transmission System
Temperature & Humidity Meter - FCC ID 2A8GT-R1610 - GLOBAL TEST SUPPLY LLC.
2A8GT-R1610

Temperature & Humidity Meter

Jan 09, 2023

Equipment Class

DTS - Digital Transmission System