FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Zhongshan Ouliang Lighting Co., LTD/
  3. 2A8PF-PH342

2A8PF-PH342Desk Lamp

Zhongshan Ouliang Lighting Co., LTD
Desk Lamp - FCC ID 2A8PF-PH342 - Zhongshan Ouliang Lighting Co., LTD
Click to zoom

Application Details

Equipment Class
DCD - Part 15 Low Power Transmitter Below 1705 kHz
Date of Grant
Sep 27, 2022
Application Purpose
Original Equipment
Date of Application
Sep 27, 2022
Equipment Note
Desk Lamp
Frequency Range
0.11100000 - 0.20500000
Company
Zhongshan Ouliang Lighting Co., LTD
Country
China

Documents & Files

Select a file to view

Users Manual

Cover Letter(s)

↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗
↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

External Photos

Page 1 of 7 FCC ID: 2A8PF-PH342 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity External Photos of the EUT Fig. 1 Page 2 of 7 FCC ID: 2A8PF-PH342 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Fig. 2 Fig. 3 Page 3 of 7 FCC ID: 2A8PF-PH342 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Fig. 4 Fig. 5 Page 4 of 7 FCC ID: 2A8PF-PH342 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Fig. 6 Fig. 7 Page 5 of 7 FCC ID: 2A8PF-PH342 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Fig. 8 Fig. 9 Page 6 of 7 FCC ID: 2A8PF-PH342 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Fig. 10 Fig. 11 Page 7 of 7 FCC ID: 2A8PF-PH342 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Fig. 12

ID Label/Location Info

Page 1 of 1 FCC ID: 2A8PF-PH342 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity LABEL AND LOCATION (Size: L: 5.0cm x W: 3.5cm) Label Location

Internal Photos

Page 1 of 6 FCC ID: 2A8PF-PH342 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Internal Photos of the EUT Fig. 1 Fig. 2 Page 2 of 6 FCC ID: 2A8PF-PH342 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Fig. 3 Fig. 4 Page 3 of 6 FCC ID: 2A8PF-PH342 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Fig. 5 Fig. 6 Coil Antenna Page 4 of 6 FCC ID: 2A8PF-PH342 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Fig. 7 Fig. 8 Page 5 of 6 FCC ID: 2A8PF-PH342 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Fig. 9 Fig. 10 Page 6 of 6 FCC ID: 2A8PF-PH342 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Fig. 11 Fig. 12

RF Exposure Info

Page 1 of 10 FCC ID: 2A8PF-PH342 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity RF Exposure Evaluation Report 1. Product Information FCC ID: 2A8PF-PH342 Product Name Desk Lamp Model Number PH342 Power Supply For Adapter: Input: AC 100-240V, 50/60Hz, 0.5A MAX Output: 5V 3A/9V 2A/12V 1.5A For Desk Lamp: Input: DC 12V Wireless charging: 10W Modulation Type ASK Frequency Range 111.0~205.0KHz Operation Frequency 125 KHz Antenna Type Coil Antenna Hardware version / Software version / Accessories / Exposure category General population/uncontrolled environment EUT Type Production Unit Device Type Mobile Device 2. Evaluation Method Per KDB 680106 D01 Section 3. RF Exposure Requirements; 1) Consumer wireless power transfer devices approved under Part 18 in some cases have to demonstrate compliance with RF exposure requirements. The potential for exposure must be assessed according to the operating configurations of the wireless system and the exposure conditions of users and bystanders. RF exposure must be evaluated with the client device(s) being charged by the primary at maximum output power. The RF exposure requirements must be determined in conjunction with the device operating characteristics, according to the mobile and portable exposure requirements in Section 2.1091 and Section 2.1093 of the rules. SAR and MPE limits do not cover the frequency range for wireless power transfer applications which operate below 100 kHz and 300 kHz respectively; therefore, RF exposure compliance needs to be determined with respect to 1.1307 (c) and (d) of the FCC rules. 2) Based on the design and implementation of the power transfer application, it must be clearly identified if mobile or portable RF exposure conditions apply. Devices that are installed to provide separation of at least 20 cm from users and bystanders may qualify for mobile exposure conditions. For some conditions where users and bystanders may be exposed at closer than 20 cm, section 2.1091(d) (4) of the rules may apply. 3) For devices designed for typical desktop applications, such a wireless charging pads, RF exposure evaluation should be conducted assuming a user separation distance of 15 cm. E and H field strength measurements or numerical modeling may be used to demonstrate compliance. Measurements should be made from all sides and the top of the primary/client pair, with the 15 cm measured from the center of the probe(s) to the edge of the device. Emissions between 100 kHz to 300 kHz should be assessed versus the limits at 300 kHz in Table 1 of Section 1.1310: Page 2 of 10 FCC ID: 2A8PF-PH342 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity 614 V/m and 1.63 A/m. A KDB inquiry is required to determine the applicable exposure limits below 100 kHz. 4) Portable exposure conditions from 100 kHz to 6 GHz are determined with respect to SAR requirements. Existing SAR systems and test procedures are generally intended for measurements above 100 MHz. While numerical modeling can be an alternative, the constraints of substantial computational resources at low frequencies could introduce further limitations. Under these circumstances, including operations below 100 kHz, the Commission may consider a combination of analytical analysis, field strength, radiated and conducted power measurements, in conjunction with some limited numerical modeling to assess compliance. 5) Depending on the operating frequency, existing SAR and MPE measurement procedures may be adapted to evaluate wireless power transfer devices for compliance with respect to mobile or portable exposure conditions. If the grantee or its test lab have any questions regarding RF exposure evaluation they should contact the FCC Laboratory with sufficient system operating configuration details to determine if RF exposure evaluation is necessary and, if required, how to apply specific test procedures. Below 100 MHz, when SAR testing is required and the device is operating at close proximity to persons, information on device design, implementation, operating configurations, exposure conditions of users and bystanders are needed to determine the evaluation and testing requirements. In addition, the influence of nearby objects may also need consideration according to the wireless power transfer system implementation; for example, the effects of placing the device, its coils or radiating elements on or near metallic surfaces 3. Evaluation Limit 3.1 Refer evaluation method ANSI C95.1–1999: IEEE Standard for Safety Levels with Respect to Human Exposure to Radio Frequency Electromagnetic Fields, 3 kHz to 300 GHz. FCC KDB publication 680106 D01 RF Exposure Wireless Charging Apps v03: RF Exposure Considerations for Low Power Consumer Wireless Power Transfer Applications FCC CFR 47 part1 1.1310: Radiofrequency radiation exposure limits. FCC CFR 47 part2 2.1091: Radiofrequency radiation exposure evaluation: mobile devices FCC CFR 47 part 18.107:Indusial, Scientific, and Medical Equipment Page 3 of 10 FCC ID: 2A8PF-PH342 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity 3.2 Limit Limits for Maximum Permissible Exposure (MPE)/Controlled Exposure Frequency Range(MHz) Electric Field Strength(V/m) Magnetic Field Strength(A/m) Power Density (mW/cm²) Averaging Time (minute) Limits for Occupational/Con…

Text truncated - open the document above for the full version.

Test Report

Zhongshan Ouliang Lighting Co., LTD Desk Lamp Supplier company name:Zhongshan Ouliang Lighting Co., LTD supplier name:Wireless charging and transmitting coil supplier address:6th Floor, Activity Center, Building 13, Yingshui Yiju, No. 8, Junjing Road, Minzhong Community Neighborhood Committee, Minzhong Street, Zhongshan City, Guangdong Province, China Unit:mm Gain:0dBi

Test Report

Page 1 of 23 FCC ID: 2A8PF-PH342 Report No.: LCSA081922106EA Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity FCC TEST REPORT For Zhongshan Ouliang Lighting Co., LTD Desk Lamp Test Model: PH342 Prepared for : Zhongshan Ouliang Lighting Co., LTD Address : 6th Floor, Activity Center, Building 13, Yingshui Yiju, No. 8, Junjing Road, Minzhong Community Neighborhood Committee, Minzhong Street, Zhongshan City, Guangdong Province, China Prepared by : Shenzhen LCS Compliance Testing Laboratory Ltd. Address : 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel : (+86)755-82591330 Fax : (+86)755-82591332 Web : www.LCS-cert.com Mail : [email protected] Date of receipt of test sample : September 05, 2022 Number of tested samples : 2 Sample No. : A081922106-1, A081922106-2 Serial number : Prototype Date of Test : September 05, 2022 ~ September 09, 2022 Date of Report : September 09, 2022 Page 2 of 23 FCC ID: 2A8PF-PH342 Report No.: LCSA081922106EA Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity FCC TEST REPORT FCC CFR 47 PART 15C Report Reference No. ................ : LCSA081922106EA Date Of Issue ................................. : September 09, 2022 Testing Laboratory Name ............ : Shenzhen LCS Compliance Testing Laboratory Ltd. Address .......................................... : 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Testing Location/ Procedure .......... : Full application of Harmonised standards ■ Partial application of Harmonised standards □ Other standard testing method □ Applicant’s Name ......................... : Zhongshan Ouliang Lighting Co., LTD Address .......................................... : 6th Floor, Activity Center, Building 13, Yingshui Yiju, No. 8, Junjing Road, Minzhong Community Neighborhood Committee, Minzhong Street, Zhongshan City, Guangdong Province, China Test Specification Standard ......................................... : FCC CFR 47 PART 15C Test Report Form No. .................... : LCSEMC-1.0 TRF Originator................................ : Shenzhen LCS Compliance Testing Laboratory Ltd. Master TRF .................................... : Dated 2011-03 Shenzhen LCS Compliance Testing Laboratory Ltd. All rights reserved. This publication may be reproduced in whole or in part for non-commercial purposes as long as the Shenzhen LCS Compliance Testing Laboratory Ltd. is acknowledged as copyright owner and source of the material. Shenzhen LCS Compliance Testing Laboratory Ltd. takes no responsibility for and will not assume liability for damages resulting from the reader's interpretation of the reproduced material due to its placement and context. Test Item Description. .................. : Desk Lamp Trade Mark ..................................... : N/A Test Model ...................................... : PH342 Power Supply ................................. : For Adapter: Input: AC 100-240V, 50/60Hz, 0.5A MAX Output: 5V 3A/9V 2A/12V 1.5A For Desk Lamp: Input: DC 12V Wireless charging: 10W Result ........................................... : Positive Compiled by: Supervised by: Approved by: Kay Hu/ Administrator Cary Luo/ Technique principal Gavin Liang/ Manager Page 3 of 23 FCC ID: 2A8PF-PH342 Report No.: LCSA081922106EA Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity FCC TEST REPORT Test Result Positive The test report merely corresponds to the test sample. It is not permitted to copy extracts of these test result without the written permission of the test laboratory. Test Report No. : LCSA081922106EA September 09, 2022 Date of issue Test Model.............................. : PH342 EUT......................................... : Desk Lamp Applicant............................... : Zhongshan Ouliang Lighting Co., LTD Address.................................. : 6th Floor, Activity Center, Building 13, Yingshui Yiju, No. 8, Junjing Road, Minzhong Community Neighborhood Committee, Minzhong Street, Zhongshan City, Guangdong Province, China Telephone............................... : / Fax.......................................... : / Manufacturer........................ : Zhongshan Ouliang Lighting Co., LTD Address................................... : 6th Floor, Activity Center, Building 13, Yingshui Yiju, No. 8, Junjing Road, Minzhong Community Neighborhood Committee, Minzhong Street, Zhongshan City, Guangdong Province, China Telephone............................... : / Fax.......................................... : / Factory................................... : ZHONGSHAN POSH LIGHTING TECHNOLOGY CO.,LTD Address................................... : No.10 Qiguan East Road, Guantang Village, Nanlang Town Zhongshan City Guangdong Province China Telephone............................... : / Fax.......................................... : / Page 4 of 23 FCC ID: 2A8PF-PH342 Report No.: LCSA081922106EA Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Revision Histor…

Text truncated - open the document above for the full version.

Test Setup Photos

Page 1 of 2 FCC ID: 2A8PF-PH342 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Test Setup Photos of the EUT Conducted Emission Radiated Emission below 30MHz Page 2 of 2 FCC ID: 2A8PF-PH342 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Radiated Emission from 30MHz to 1GHz

Contact Information

Applicant

Zhiwei Ma
[email protected]0760-23838888Fax: 0760-22313456-8532

Test Firm

Shenzhen LCS Compliance Testing Laboratory Ltd.Gavin Liang
[email protected]0755-82591330Fax: 0755-82591132

Technical Specifications

#Rule PartsFrequency RangePower Output
115C0.111 MHz - 0.205 MHz-
Confidentiality
Long Term