1 Televend Box Installation Safety Requirements Content: 1. General notes 2. Protection against electric shock 3. Televend Box installation 4. Overvoltage protection 5. Current consumption of payment system 6. Overcurrent protection 7. Selective overcurrent protection against device overloads 8. Overcurrent protection against galvanic contact 2 1. General notes 1.1. Televend Box in not readily available for average consumer because average consumer does not have necessary knowledge and skills required for proper installation regarding functionality and safety. Therefore installation can be done only by means of professional installation. 1.2. Operation and maintenance can be performed only by skilled service personnel. 1.3. Follow safety requirements as mandatory. 1.4. Use good engineering practice. 1.5. Ensure compliance with country/regional specific technical normative laws and standards. 2. Protection against electric shock 2.1. Vending machine must have correct protection for external metallic surfaces and parts which are touchable by customer, and must have correct protection for internally exposed metallic surfaces and parts which are touchable by service personnel. 2.2. Ensure correct power and protective earth connection of vending machine to certified and maintaned building electricall installation. 2.3. AC or DC power supply unit of vending machine which powers Televend must be of safe class extra-low-voltage ELV, SELV or PELV. 3. Televend Box installation 3.1. Fix devices to have correct mechanical stability regarding handling, operation and vibrations. 3.2. Avoid any mechanical stress, bending or twisting of devices during installation and operation. 3.3. Devices must have galvanic isolation to other metallic surfaces and parts, because otherwise galvanic contact can cause malfunctions due to leakage currents or high fault currents. 3.4. Use safe distance from heat sources, moisture, or dripping liquids. 3.5. Enable free flow of air around devices. 3.6. Arrange cable routes to avoid any mechanical stress and cable damage, because otherwise damaged cables can cause malfunctions or high fault currents. 3.7. Cable connection and disconnection must be done only during power-off condition. 3.8. Place antennas as far as possible from metal parts. 4. Overvoltage protection 4.1. Power supply unit of vending machine which powers Televend must have protection against overvoltages according to relevant EXECUTIVE/MDB/BDV/CSI normative min/max peak voltage levels. 3 5. Current consumption of payment system 5.1. Current consumption of devices of payment system in idle mode and operating modes must be within limits of current ratings of Televend. o Check technical datasheets and ensure that current consumption is within permitted current ratings. o If current consumption of EXECUTIVE/MDB configuration is out of current ratings of internal AC/DC power supply then use external DC power supply. 6. Overcurrent protection 6.1. Power supply unit of vending machine which powers Televend must have overcurrent protection in order to protect itself against excessive current levels and to protect cable installation and powered devices against high fault currents and overloads. Overcurrent protection must be set correctly according to: o Current rating of power supply unit o Current ratings of Televend o Current consumption of powered devices o Inrush currents of powered devices 6.2. If overcurrent protection of power supply unit can not be set correctly then: o Use additional cable of type protection-cable with in-line fuses, and insert it as first one to power supply. 7. Selective overcurrent protection against device overloads 7.1. When overcurrent protection is set on relatively high current level, then for particular devices it can not be effective protection against overloads. If there is requirement for selectivity for some or for all devices to have overload protection then: o For each required device of payment system and for Televend device use additional cable of type protection-cable with in-line fuses, and insert it as first one to device. o Note that selective overcurrent protection of Televend device for configuration EXECUTIVE/MDB requires usage of external DC power supply. 4 8. Overcurrent protection against galvanic contact 8.1. When there is high risk of galvanic contact then: o Use additional cable of type protection-cable with in-line fuses, and insert it as first one to Televend. o Note that protection against galvanic contact for configuration EXECUTIVE/MDB requires usage of external DC power supply.
SMART VENDING Quick installation guide Basic step by step cloud and box manual ver.2.7 date: 10.08.2018. Televend Quick Installation Page 2 of 14 Content 1 Revision history .................................................................................................................. 3 2 Cloud log in ......................................................................................................................... 4 3 Input basic data to cloud ..................................................................................................... 4 4 Create machine on cloud .................................................................................................... 4 5 Add Televend configuration & Choose payment systems .................................................... 5 6 Add products to machine .................................................................................................... 6 7 Antenna types ..................................................................................................................... 6 8 Plug in the box to machine and payment system ................................................................ 7 Explanation of connection scheme possible functionalities ..................................................... 7 MDB brain: ............................................................................................................................. 8 BRAIN: ................................................................................................................................... 8 EXE brain ............................................................................................................................... 9 BDV BRAIN: ........................................................................................................................... 9 IMPORTANT MECHANICAL PROTECTION NOTES: .......................................................... 10 9 Machine Online – push product list ................................................................................... 10 10 Basic test check ............................................................................................................ 11 11 Televend buttons ........................................................................................................... 11 11.1 Selling (normal) mode – confirmation of visit actions ................................................. 11 11.2 Button functions in Service mode ............................................................................... 12 11.3 LEDs .......................................................................................................................... 13 Televend Quick Installation Page 3 of 14 1 Revision history Version Date Author(s) Change 2.4 14.09. 2017 Nikola Runjavec BDV protocol connection 2.5 13.12.2017 Romana Rožić Antenna types description 2.6 29.06.2018 Vedran Plavec Enhanced LED behavioral 2.7 10.08.2018 Nikola Runjavec Televend Quick Installation Page 4 of 14 2 Cloud log in Log in to the cloud with given credentials. Recommended browsers are Google Chrome or Mozilla Firefox. a. Link: http://televendcloud.com/en/login b. Username: your e – mail c. Password: your given password 3 Input basic data to cloud When logged in go to “ADMINISTRATION” and create the following in this order > Region, Location, Tax Rate, Products. If you have a coffee product first create Components – for example Sugar, Cups, Coffee beans etc. When creating a coffee product click “Add recipe”. 4 Create machine on cloud Before connecting the box to the machine create the machine on cloud in Administration > Machines > “Add new machine”. In machine settings PID is the serial number printed on the Televend box. Televend Quick Installation Page 5 of 14 5 Add Televend configuration & Choose payment systems In Televend configuration select wanted Televend operation mode Brain, MDB brain, EXE brain etc. Scroll below to choose active payment systems: Televend Quick Installation Page 6 of 14 6 Add products to machine Add products which you have created in the first step to the machine in products tab. Note: column numbers must match the selections (button numbers) defined on the machine. For example: 7 Antenna types There are four antenna types that can be delivered with the Televend box set : a) AN01-BT- 2,1 dBi external antenna type, mounted directly on Televend box, next to GSM antenna, can be used for offline data collection or Wallet b) AN02-2,1 dBi the so called inner antenna, should be placed on plastic surface inside of the machine c) AN03- 5,0 dBi external antenna type, used in places with very bad signal strength d) AN03S- 2,2 dBi external antenna type, used in places with lower signal strength Televend Quick Installation Page 7 of 14 8 Plug in the box to machine and payment system Explanation of connection scheme possible functionalities P - machine processor (controller) C – coin changer C1,C2 – cashless devices (address 1, address 2) BNA – banknote acceptor Televend Quick Installation Page 8 of 14 MDB brain: Recommended settings of machine and box: - Make sure machine and payment systems are set to MDB - In this configuration machine recognizes Televend box as cashless device – make sure cashless is enabled in the machine settings - Recommended price setting of Televend box is “Price on VMC” BRAIN: NOTE! – AC CABLE (power supply) also needed in this configuration Recommended settings of machine and box: - Make sure machine is set to EXE and payment systems are set to MDB - In this configuration machine recognizes Televend box as a coin changer – make sure coin changer is enabled in machine settings - Recommended price setting of Televend box is “Price hold display” NOTE: In EXE brain and BRAIN configuration, in some machines prices and selection numbers need to be defined like following in order to control prices over cloud and dial selections: Televend Quick Installation Page 9 of 14 Selection …
Text truncated - open the document above for the full version.
Attestation Statements February 14, 2023 TO: Federal Communications Commission Authorization and Evaluation Division 7435 Oakland M ills Road Columbia, MD 2 1046, USA RE: A ttestation Statements Part 2.911(d)(7} request for 2A8XO-TE36Y2209 INTIS Lt d. for trading, engineering and services, the undersigned, hereby authorize Dr Michael Rau of Clevver Legal Services LLP to act as our designated U.S. agent for service of process, INTIS Ltd. for tr ading, engineering and services accepts to maintain an agent for no less than one year after the grantee has terminated all marketing and importation or the conclusion of any C ommission-related proceeding involving the equipment. Dr M ichael Rau accepts the responsibility to act as designated U.S. agent for service of process, provides an agent for no less than one year after the grantee has terminated all marketing and importation or the conclusion of any Commission-related proceeding involving the equipment. Applicant Information: Company name: INTIS Ltd. for trading, engineering and services Contact Name: Filip Fabac Address: Bani 73a, Zagreb, Croatia Telephone No: +385 91 1804 481 Email: [email protected] U.S. Agent Information: Company Name: C levver Legal Services LLP A ddress: 1201 N Orange Street Suite 7160 Wilmington DE 19801 C ontact Name: Dr. Michael Rau Telephone No: +1-302-691-9073 Email:[email protected] FRN:0033416413 //_, / \ fl/f . / 1 . Applicant Signature: _ Agent Signature : / 1 r • l 'hi( t·/,, ;, (if the agent is different from the applicant} Applicant printed name: Agent printed name: Dr. Michael Rau INTIS Ltd. for trading, engineering and services Represented b V; : l:>. � ar i � . , � - er; Vlim Loncar . .
Registered under no. MBS 080146714 Director: Vilim Lončar Commercial Court in Zagreb, Croatia Erste & Steiermärkische Bank d.d., Account No. 7001-3686914, IBAN: HR2124020061100051818, SWIFT: ESBCHR22 INTIS Ltd. for trading, engineering and services Bani 73a, Buzin, HR - 10010 Zagreb, Croatia Tel.: +385 1 7890-800, Fax: +385 1 7890-888 e-mail: [email protected], www.intis.eu ID: 3686914, OIB: 12987689544 VAT Reg. No.: HR12987689544 8 TH November 2022 Eurofins MET labs 914 West Patapsco Avenue Baltimore, MD 21230 RE: Short Term Confidentiality Request For EUT NAME Vending Telemetrv Apparatus MODEL TE36 AND FCC 2A8XO-TE36Y2209) To Whom It May Concern: In accordance with sections 0.457 and 0.459 of CFR 47, INTIS requests short-term Confidentiality of following sections of this application for a period of 180 days after grant is issued. Test setup photos External photos Internal photos User's manual These documents contain detailed system and equipment descriptions and related information about the product, which INTIS considers to be proprietary, confidential, and a custom design and otherwise, would not release to the general public. Since this design is a basis from which future technological products will evolve, INTIS feels that this information would be ofbenefit to its competitors, and that the disclosure of the information in these documents would give our competitors an unfair advantage in the market. Please contact me if there is any information you may need. Sincerely, Must be signed by the applicant contact cited as technical or non-technical contact on the 731 forrn provided to Eurofins MET Labs, or by the authorized agent if an appropriate authorized agent letter has been provided. Letters signed by the applicant should be placed on applicant letterhead.
SIQ Ljubljana, Mašera-Spasićeva ulica 10, SI-1000 Ljubljana, Slovenia T +386 1 4778 100, F +386 1 4778 444, [email protected], www.siq.si External photos Project file: C20212917 Date: 2022-11-02 Pages: 3 Product: Vending Telemetry Apparatus Type reference: TE36 Page: 2 (3) Figure 1 Figure 2 Page: 3 (3) Figure 3 Figure 4
Model: Televend Type: TE36 Version: 3.6 HVIN: HW-T3.6 www.televend.eu Made in EU 2209100003 Serial number: FCC ID: 2A8XO-TE36Y2209 Contains FCC ID: 2AJYU-8PYA007 IC: 29470-TE36Y2209 Contains IC: 23761-8PYA0008 Power [50/60Hz]: 18V - 30V / 10W Power [DC]: 15V - 42V / 10W Intis Ltd. Bani 73a, 10010 Zagreb, Croatia
SIQ Ljubljana, Mašera-Spasićeva ulica 10, SI-1000 Ljubljana, Slovenia T +386 1 4778 100, F +386 1 4778 444, [email protected], www.siq.si Internal photos Project file: C20212917 Date: 2022-11-02 Pages: 2 Product: Vending Telemetry Apparatus Type reference: TE36 Page: 2 (2) Figure 1 Figure 2
The report shall not be reproduced except in full. SIQ Ljubljana, Mašera-Spasićeva ulica 10, SI-1000 Ljubljana, Slovenia T +386 1 4778 100, F +386 1 4778 444, [email protected], www.siq.si TN405E-03 Test report Number T251-0721/22 Project file: C20212917 Date: 2022-10-20 Pages: 44 Product: Vending Telemetry Apparatus Type reference: TE36 Ratings: 18 – 30 Vac or 15 - 42 Vdc Protection class: III Trademark: TELEVEND Applicant: INTIS Ltd. for trading engineering and services Bani 73a, HR-10010 Zagreb, Croatia Manufacturer: INTIS Ltd. for trading engineering and services Bani 73a, HR-10010 Zagreb, Croatia Place of manufacture: INTIS Ltd. for trading engineering and services Bani 73a, HR-10010 Zagreb, Croatia Summary of testing Testing method: 47 CFR Part 15, Subpart C (Clause 15.247) in conjuction with ANSI C63.10.2013 Testing location: SIQ Ljubljana Mašera-Spasićeva ulica 10, SI-1000 Ljubljana, Slovenia Remarks: Date of receipt of test items: 2022-09-02 Number of items tested: 1 Date of performance of tests: 2022-09-05 - 2022-09-12 The test results presented in this report relate only to the items tested. The product complies with the requirements of the testing methods. Tested by: Luka Cvajnar Approved by: Marjan Mak T251-0721/22 Page: 2 (44) CONTENTS Page 1 GENERAL 3 1.1 DESCRIP TION OF EQUIPMENT UNDER TEST 3 1.2 DESCRIP TION OF THE TES T MODES 3 1.3 TEST EQUIPMENT USED FOR TES TING 4 1.4 TEST SETUP CONFIGURA TIONS 5 2 TEST SUMMARY 7 2.1 APPLICA TION OF DECIS ION RULE 7 3 TESTS RESULTS 8 3.1 47 CFR § 15.203 – ANTENNA REQUIREME NTS 8 3.2 47 CFR § 15.207 – AC LINE CONDUCTED EMISSION 9 3.3 47 CFR § 15.247(D) - SPURIOUS EMISSION - COND UCTED 11 3.4 47 CFR § 15.205, § 15.209, § 15.247 (D) – SPURIOUS EMISSION - RADIA TED 13 3.5 47 CFR § 15.247 (A) (2) – 6 DB EMISSION BA NDWIDTH 30 3.6 47 CFR § 15.247 (B) (3) – MAXIMUM PEAK OUTPUT POWE R 33 3.7 47 CFR § 15.247 (D) –100 KHZ BANDWID TH OF FRE QUE NCY BA ND EDGE 34 3.8 47 CFR § 15.247 (E) – POWER SPECTRAL DE NSITY 39 4 ANNEX I – ADDITIONAL DATA 41 4.1 OCCUPIED BANDWID TH (99% EMISS ION BANDWID TH) 42 T251-0721/22 Page: 3 (44) 1 GENERAL EUT passed the performed tests. History sheet Date Report No. Change Revision 2022-10-20 T251-0721/22 Initial Test Report issued. -- 1.1 Description of equipment under test Vending Telemetry Apparatus Type: TE36 FCC ID: 2A8XO-TE36Y2209 Contains FCC ID: 2AJYU-8PYA007 IC: 29470- TE36Y2209 Contains IC: 23761-8PYA0008 Adaptive / non-adaptive equipment non-adaptive equipment Modulation type Other than FHSS Operating mode Single antenna Operating temperature range -20 °C to +55 °C Maximum RF Output power 4 dBm Operating frequency 2402 MHz – 2480 MHz Number of channels 40 Antenna type and gain External antenna (SMA male), <2dBi Antenna Beamforming / Nominal channel bandwidth 1 MHz Hardware version: HW-T3.6 Software version: FW-T3.6 1.2 Description of the test modes The equipment uses only one antenna at any moment. On all devices run test firmware Bluetooth Direct Test Mode and accompanied by a USB-UART converter interface. For testing purposes sample with SMA connector was provided. For testing nRFgo Studio software program from Nordic Semiconductor was used. 1.2.1 Tested Channels Channels Data rate Frequency [MHz] TX power Settings [dBm] Packet type Packet length (bytes) 0 (Lowest) 1 Mbps 2402 4 PRBS9 37 19 (Middle) 1 Mbps 2440 4 PRBS9 37 39 (Highest) 1 Mbps 2480 4 PRBS9 37 Normal test condition: Ambient temperature: 15 C to 35 C Relative humidity: 30 % to 60 % Atmospheric pressure: 860 mbar to 1060 mbar T251-0721/22 Page: 4 (44) 1.3 Test Equipment used for testing Manufacturer Description Model No. Used Calibrated Calibrated until Comtest engineering, SAC2 (together with controlling equipment) SAC 3m X 2022-04-14 2025-04-14 Maturo, Turn table (2 m diameter) TT 2.0 SI X / / Maturo, Bore-sight antenna mast BAM-4.0-P X / / Maturo, positioning equipment NCD X / / Rohde & Schwarz, RFI receiver ESU 26 X 2021-05-10 2022-11-10 R&S, Ultra Broadband Antenna HL562E X 2020-09-30 2022-09-30 R&S, Horn Antenna HF907 X 2020-08-21 2022-08-21 R&S, Spectrum Analyzer FSV 40 X 2021-04-30 2022-10-30 R&S, Vector signal generator SMBV100B / / / R&S, Signal generator SMB100A X 2021-04-30 2022-10-30 R&S High resolution power meter OSP-B157W8 X 2021-05-03 2022-11-03 R&S Switch unit OSP-B157WX X 2021-05-03 2022-11-03 Wainwright Instruments, High pass filter High pass filter WHNX6-2555- 3500-26500 X 2020-06-08 2023-06-08 Wainwright Instruments, High pass filter WHNX6-5925- 7500-26500 / / / Wainwright Instruments, High pass filter WHW2-16340- 21500-40000 / / / Hp, Manual step attenuator 8494B 11 DB X / / Hp, Manual step attenuator 8496B 110 DB X / / PMI Low noise amplifier PEC-42-1G40G X 2022-04-19 2023-10-19 KEYSIGHT, attenuator 8491B 10 DB / / / Fluke, Digital Multimeter 87V X 2021-11-30 2022-11-30 Kambič, Temperature chamber I-190 CK X / / 1.3.1 Measurement uncertainty The following measurement uncertainty levels have been estimated for tests performed on the product, as specified in ETSI TR 100 028-2 and C63.23. This represents an expanded uncertainty expressed at 95% confidence level using a coverage factor k=2. Measurements ULAB U ETSI TR 100 028-2 U C63.23 AC Line Conducted Emission 3.2 dB / ±4,13 Spurious emission 30 – 300 MHz 4.2 dB ±6 / Spurious emission 300 – 1000 MHz 4.4 dB ±6 / Spurious emission 1 GHz – 18 GHz 5.1 dB ±6 / Spurious emission 18 GHz – 26GHz 5.6 dB ±6 / Tx spurious emission - conducted < 1.8 dB ±4 / 6 dB Emission Bandwidth < 2% ±5% / Maximum peak output power < 1 dB ±0,75 dB / 100 kHz Bandwidth of Frequency Band Edge < 0.8 dB / / Power Spectral Density < 1.3 dB ±3 dB / Occupied bandwidth (99% emission bandwidth) < 2% ±5% / Note: Measurement uncertainty calculated in accordance with ETSI TR 100 028-2 and C63.23. T251-0721/22 Page: 5 (44) 1.4 Test setup configurations 1.4.1 Conducted measurement test setup 1.4.2 Radiated measurement test setup Note: Bellow 1G non-conductive Table 80 cm above ground plane and above 1G non-conductiv…
Text truncated - open the document above for the full version.
The report shall not be reproduced except in full. SIQ Ljubljana, Mašera-Spasićeva ulica 10, SI-1000 Ljubljana, Slovenia T +386 1 4778 100, F +386 1 4778 444, [email protected], www.siq.si TN405E-03 Test report Number T251-0859/22 Project file: C20212917 Date: 2022-11-15 Pages: 5 Product: Vending Telemetry Apparatus Type reference: TE36 Ratings: 18 – 30 Vac or 15 - 42 Vdc Protection class: III Trademark: TELEVEND Applicant: INTIS Ltd. for trading engineering and services Bani 73a, HR-10010 Zagreb, Croatia Manufacturer: INTIS Ltd. for trading engineering and services Bani 73a, HR-10010 Zagreb, Croatia Place of manufacture: INTIS Ltd. for trading engineering and services Bani 73a, HR-10010 Zagreb, Croatia Summary of testing Testing method: 47 CFR FCC Part 1.1307(clause (b)(1)(i)(B) and (b)(3)(ii)(B)), KDB 447498 D01 General RF Exposure Guidance v06 Testing location: SIQ Ljubljana Mašera-Spasićeva ulica 10, SI-1000 Ljubljana, Slovenia Remarks: Date of receipt of test items: 2022-09-02 Number of items tested: 1 Date of performance of tests: 2022-11-15 The test results presented in this report relate only to the items tested. The product complies with the requirements of the testing methods. Tested by: Luka Tosetto Approved by: Marjan Mak T251-0859/22 Page: 2 (5) CONTENTS page 1 GENERAL 3 1.1 EQUIPMENT UNDER TEST 3 2 ASSESSMENT PROCEDURE 4 3 MEASUREMENTS / CALCULATIONS 5 T251-0859/22 Page: 3 (5) 1 GENERAL History sheet Date Report No. Change Revision 2023-01-20 T251-0859/22 Initial Test Report issued. -- 1.1 Equipment under test Vending Telemetry Apparatus Type: TE36 Environment: Uncontrolled / General Public Assessment distance: ≥20 cm FCC ID: 2A8XO-TE36Y2209 Contains FCC ID: 2AJYU-8PYA007 Reviewed test report T251-0721/22 from SIQ Ljubljana. T251-0859/22 Page: 4 (5) 2 ASSESSMENT PROCEDURE MPE EVALUATION OF FIXED DEVICES According to 47 CFR 1.1307 clause (b)(1)(i)(B): With respect to the limits on human exposure to RF provided in § 1.1310 of this chapter, applicants to the Commission for the grant or modification of construction permits, licenses or renewals thereof, temporary authorities, equipment authorizations, or any other authorizations for radiofrequency sources must prepare an evaluation of the human exposure to RF radiation pursuant to § 1.1310 and include in the application a statement confirming compliance with the limits in § 1.1310. Limits: Calculation: P d = P t 4 * * R 2 Where: P d = Power density in mW/cm2 P t = EIRP in mW = 3.14 R = Evaluation distance According to 47 CFR 1.1307 clause (b)(3)(ii)(B)): (ii) For multiple RF sources: Multiple RF sources are exempt if: (B) in the case of fixed RF sources operating in the same time-averaging period, or of multiple mobile or portable RF sources within a device operating in the same time averaging period, if the sum of the fractional contributions to the applicable thresholds is less than or equal to 1 as indicated in the following equation. T251-0859/22 Page: 5 (5) 3 MEASUREMENTS / CALCULATIONS Values for each configuration are listed in the following table: Frequency (MHz) Maximum* Power with antenna gain and tune-up (dBm) Maximum* Power with antenna gain and tune-up (mW) Power Density (mW/cm2) Limit (mW/cm2) 2402 4.7 2.95 0.0009355 1 2440 4.7 2.95 0.0009355 1 2480 4.3 2.69 0.0008560 1 * Gated power with Duty Cycle calculated in ** maximum tolerance provided from manufacturer is ±2dB. Conclusion: PASS
www.2j-antennae.com Page: 1/4 2J0A02-2,4GHz-C91G (DATASHEET) Type WiFi/Bluetooth antenna Frequencies WIFI / BLUETOOTH (2.4 GHz) Mounting Telematic Revision 00 www.2j-antennae.com Page: 2/4 1. SPECIFICATION 1.1. Electrical Specifications Frequencies WIFI / BLUETOOTH (2.4 GHz) Impedance 50 Ohms Polarization Linear Gain < 2dBi max. VSWR <2:1 Operating temperature -40°C to +85°C 1.2. Connection Specifications Connector type: SMA male, gold 1.3. Mechanical Specifications and Dimensions Max. dimensions: 44mm x 9.6mm (H x D) Weight: 6g Colour: Black (for different colours please ask our sales team) www.2j-antennae.com Page: 3/4 2. MEASUREMENT Measured directly on analyzer N9923A VSWR LOG MAG www.2j-antennae.com Page: 4/4 3D radiation pattern 2.44 GHz 3. PICTURES
SIQ Ljubljana, Mašera-Spasićeva ulica 10, SI-1000 Ljubljana, Slovenia T +386 1 4778 100, F +386 1 4778 444, [email protected], www.siq.si Test setup photos Project file: C20212917 Date: 2022-11-02 Pages: 4 Product: Vending Telemetry Apparatus Type reference: TE36 Page: 2 (4) Figure 1: Spurious emission 90 kHz-30 MHz Figure 2: Spurious emission 30 MHz-1000 MHz Page: 3 (4) Figure 3: Spurious emission 1-18 GHz Figure 4: Spurious emission 18- 26 GHz Page: 4 (4) Figure 5: Conducted measurements test setup Figure 6: Conducted measurements on AC lines test setup
Bani 73a · Zagreb · Croatia
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 2.40 GHz - 2.48 GHz | 1.17 mW |