Yunjing Intelligence Innovation (Shenzhen) Co., Ltd. U.S. Agent Letter of Attestation To: Federal Communications Commission Date: 2026-05-12 7435 Oakland Mills Road, Columbia, MD 21046, USA Ref: Attestation Statement – Part 2.911(d)(7) filing FCC ID: 2A942YJCC040 Yunjing Intelligence Innovation (Shenzhen) Co., Ltd. (“the applicant”) certifies that, as of the date of the filing of the application, Narwal Robotics Corporation (“the agent”) is our designated U.S. agent for service of process for the above reference FCC ID. The applicant accepts to maintain an agent for service of process in the United States for no less than one year after either the grantee has permanently terminated all marketing and importation of the applicable equipment within the U.S., or the conclusion of any Commission-related administrative or judicial proceeding involving the equipment, whichever is later. The applicant further acknowledges it is our responsibility to inform the FCC whenever the agent information changes. Narwal Robotics Corporation (“the agent”) understand it is the agent's obligation to accept service of process in the United States for matters related to the applicable equipment, and at the physical U.S. address and email address. APPLICANT Company Name: Yunjing Intelligence Innovation (Shenzhen) Co., Ltd. Contact Person: Honglei.yan Address: Room A2901, Building 1, Vanke Yuncheng VI, Dashi 2nd Road, Nanshan District, Shenzhen, China Tel.: 15889312514 Email: [email protected] FRN: 0033343674 U.S. Agent Company Name: Narwal Robotics Corporation Contact Person: Rena.yan Address: 442 N BARRANCA AVE. SUITE 180. COVINA, CA 91723 Tel.: 213 316 6586 Email: [email protected] U.S. Agent FRN: 0035440049 Sincerely yours, The Applicant The Agent Company Name Yunjing Intelligence Innovation (Shenzhen) Co., Ltd. Narwal Robotics Corporation Contact Person Honglei Yan Rena Yan Signature
Yunjing Intelligence Innovation (Shenzhen) Co., Ltd. Attestation Statements Not Covered Entity Applicant To: Federal Communications Commission Date: 2026-05-12 7435 Oakland Mills Road, Columbia, MD 21046, USA Ref: Information Required by Section 2.911(d)(5)(ii) filing FCC ID: 2A942YJCC040 Yunjing Intelligence Innovation (Shenzhen) Co., Ltd. (“the applicant”) certifies that, as of the date of the filing of the application, the applicant is not identified on the Covered List (as a specifically named entity or any of its subsidiaries or affiliates) as an entity producing “covered” equipment. Sincerely, ______________________ Signature Printed name: Honglei Yan Title: Product Compliance Manager
Yunjing Intelligence Innovation (Shenzhen) Co., Ltd. Attestation Statements Not Covered Equipment To: Federal Communications Commission Date: 2026-05-12 7435 Oakland Mills Road, Columbia, MD 21046, USA Ref: Information Required by Section 2.911(d)(5)(i) filing FCC ID: 2A942YJCC040 Yunjing Intelligence Innovation (Shenzhen) Co., Ltd. (“the applicant”) certifies that the equipment for which authorization is sought is not “covered” equipment prohibited from receiving an equipment authorization pursuant to section § 2.903 of the FCC rules. Sincerely, ______________________ Signature Printed name: Honglei Yan Title: Product Compliance Manager
TCB Authority to Act as Agent Number: MS-0045317 Revision: 0 Effective date: Oct 8, 2021 Page 1 of 1 Yunjing Intelligence Innovation (Shenzhen) Co., Ltd. Authority to Act as Agent Date: 2026-05-12 TUV Rheinland of North America, Inc. 1279 Quarry Lane., Suite. A Pleasanton, CA 94566 To Whom It May Concern: I appoint TÜV Rheinland (Shenzhen) Co., Ltd. to act as our agent in the preparation of this application for equipment certification. I certify that submitted documents properly describe the device or system for which equipment certification is sought. I also certify that each unit manufactured, imported or marketed, as defined in the FCC or Industry Canada’s regulations will have affixed to it a label identical to that submitted for approval with this application. For instances where our authorized agent signs the application for certification on our behalf, I acknowledge that all responsibility for complying with the terms and conditions for Certification, as specified by TUV Rheinland Group, still resides with Yunjing Intelligence Innovation (Shenzhen) Co., Ltd., Room A2901, Building 1, Vanke Yuncheng VI, Dashi 2nd Road, Nanshan District, Shenzhen, China. For TCB applications, We certify that we are not subject to denial of federal benefits, that includes FCC benefits, pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C. 862. Further, no party, as defined in 47 CFR 1.2002 (b), to the application is subject to denial of federal benefits, that includes FCC benefits. Agency Agreement Date: 2026-05-20 Agreement is valid for 12 months from the above date. Sincerely, ______________________ Signature Printed name: Honglei Yan Title: Product Compliance Manager On behalf of Yunjing Intelligence Innovation (Shenzhen) Co., Ltd.
MS-0044715 Page 1 of 1 Revision 1 Yunjing Intelligence Innovation (Shenzhen) Co., Ltd. Date: 2026-05-12 Federal Communications Commission Equipment Authorization Branch 7435 Oakland Mills Road, Columbia, MD 21046, USA Subject: Confidentiality Request for FCC ID: 2A942YJCC040 Pursuant to FCC 47 CRF 0.457(d), the applicant requests that a part of the subject FCC/IC application be held confidential. Type of Confidentiality Requested Exhibit Short Term Permanent Block Diagrams Short Term Permanent External Photo Short Term Permanent Internal Photos *** Short Term Permanent Operation Description/Theory of Operation Short Term Permanent Schematics Short Term Permanent Test Setup*** Short Term Permanent Tune-Up Procedure Short Term Permanent User’s Manual*** Short Term Permanent Part List/ Antenna Gain Information Datasheet Yunjing Intelligence Innovation (Shenzhen) Co., Ltd. has spent substantial effort in developing this product and it is one of the first of its kind in industry. Having the subject information easily available to "competition" would negate the advantage they have achieved by developing this product. Not protecting the details of the design will result in financial hardship. Permanent Confidentiality: The applicant requests the exhibits listed above as permanently confidential be permanently withheld from public review due to materials that contain trade secrets and proprietary information not customarily released to the public. (*** Exceptional case for Permanent Confidentiality for these Exhibits by PAG only). Short-Term Confidentiality: The applicant requests the exhibits selected above as short term confidential be withheld from public view for a period of 180 days from the date of the Grant of Equipment Authorization and prior to marketing. This is to avoid premature release of sensitive information prior to marketing or release of the product to the public. Applicant is also aware that they are responsible to notify TUV Rheinland in the event information regarding the product or the product is made available to the public. TUV Rheinland will then release the documents listed above for public disclosure pursuant to FCC Public Notice DA 04-1705. Sincerely, ______________________ Signature Printed name: Honglei Yan Title: Product Compliance Manager
Label Label Location
Prüfbericht - Produkte Test Report - Products Prüfbericht-Nr.: Test report no.: CN262VO7 003 Auftrags-Nr.: Order no.: 27226076 Seite 1 von 10 Page 1 of 10 Kunden-Referenz-Nr.: Client reference no.: N/A Auftragsdatum: Order date: 2026-03-26 Auftraggeber: Client: Yunjing Intelligence Innovation (Shenzhen) Co., Ltd. Room A2901, Yunzhongcheng, Building 1, Vanke Yuncheng VI, Dashi 2nd Road, Xili Community, Xili Street, Nanshan District, Shenzhen, Guangdong, China Prüfgegenstand: Test item: Robot Vacuum and Mop Bezeichnung / Typ-Nr.: Identification / Type no.: YJCC040 (Trademark: NARWAL) Auftrags-Inhalt: Order content: Test Report Prüfgrundlage: Test specification: CFR Title 47 FCC Part 2: Section 2.1091 RSS-102 Issue 6 December 2023 Wareneingangsdatum: Date of sample receipt: 2026-04-02 Please refer to Photo Document Prüfmuster-Nr.: Test sample no: A004241255-009/010 Prüfzeitraum: Testing period: 2026-04-27 - 2026-05-11 Ort der Prüfung: Place of testing: TÜV Rheinland (Shenzhen) Co., Ltd. Prüflaboratorium: Testing laboratory: TÜV Rheinland (Shenzhen) Co., Ltd. Prüfergebnis*: Test result*: Pass geprüft von: tested by: X Signed by: Lin Lin genehmigt von: authorized by: X Signed by: Hardy Suo Datum: Date: 2026-05-15 Ausstellungsdatum: Issue date: 2026-05-15 Stellung / Position: Sachverständige(r)/Expert Stellung / Position: Sachverständige(r)/Expert Sonstiges / Other: FCC ID: 2A942YJCC040 IC: 30051-YJCC040 HVIN: YJCC040 Zustand des Prüfgegenstandes bei Anlieferung: Condition of the test item at delivery: Prüfmuster vollständig und unbeschädigt Test item complete and undamaged * Legende: P(ass) = entspricht o.g. Prüfgrundlage(n) F(ail) = entspricht nicht o.g. Prüfgrundlage(n) N/A = nicht anwendbar N/T = nicht getestet * Legend: P(ass) = passed a.m. test specification(s) F(ail) = failed a.m. test specification(s) N/A = not applicable N/T = not tested Dieser Prüfbericht bezieht sich nur auf das o.g. Prüfmuster und darf ohne Genehmigung der Prüfstelle nicht auszugsweise vervielfältigt werden. Dieser Bericht berechtigt nicht zur Verwendung eines Prüfzeichens. This test report only relates to the above mentioned test sample. Without permission of the test center this test report is not permitted to be duplicated in extracts. This test report does not entitle to carry any test mark. TUV Rheinland (Shenzhen) Co., Ltd., 1601-1604, 1801-1804, Tower A Building 2, Shenzhen International Innovation Valley, Dashi 1st Road, Xili Street, Xili Community, Nanshan District, Shenzhen, 518000 Mail: [email protected] · Web: www.tuv.com V101023GCNSR Prüfbericht - Produkte Test Report - Products Prüfbericht-Nr.: CN262VO7 003 Test report no.: Seite 2 von 10 Page 2 of 10 Anmerkungen Remarks 1 Alle eingesetzten Prüfmittel waren zum angegebenen Prüfzeitraum gemäß eines festgelegten Kalibrierungsprogramms unseres Prüfhauses kalibriert. Sie entsprechen den in den Prüfprogrammen hinterlegten Anforderungen. Die Rückverfolgbarkeit der eingesetzten Prüfmittel ist durch die Einhaltung der Regelungen unseres Managementsystems gegeben. Detaillierte Informationen bezüglich Prüfkonditionen, Prüfequipment und Messunsicherheiten sind im Prüflabor vorhanden und können auf Wunsch bereitgestellt werden. The equipment used during the specified testing period was calibrated according to our test laboratory calibration program. The equipment fulfils the requirements included in the relevant standards. The traceability of the test equipment used is ensured by compliance with the regulations of our management system. Detailed information regarding test conditions, equipment and measurement uncertainty is available in the test laboratory and could be provided on request. 2 Wie vertraglich vereinbart, wurde dieses Dokument nur digital unterzeichnet. Der TÜV Rheinland hat nicht überprüft, welche rechtlichen oder sonstigen diesbezüglichen Anforderungen für dieses Dokument gelten. Diese Überprüfung liegt in der Verantwortung des Benutzers dieses Dokuments. Auf Verlangen des Kunden kann der TÜV Rheinland die Gültigkeit der digitalen Signatur durch ein gesondertes Dokument bestätigen. Diese Anfrage ist an unseren Vertrieb zu richten. Eine Umweltgebühr für einen solchen zusätzlichen Service wird erhoben. Informationen zur Verifizierung der Authentizität unserer Dokumente erhalten Sie auf folgender Webseite: go.tuv.com/digital-signature As contractually agreed, this document has been signed digitally only. TUV Rheinland has not verified and unable to verify which legal or other pertaining requirements are applicable for this document. Such verification is within the responsibility of the user of this document. Upon request by its client, TUV Rheinland can confirm the validity of the digital signature by a separate document. Such request shall be addressed to our Sales department. An environmental fee for such additional service will be charged. For information on verifying the authenticity of our documents, please visit the following website: go.tuv.com/digital-signature 3 Prüfklausel mit der Note * wurden an qualifizierte Unterauftragnehmer vergeben und sind unter der jeweiligen Prüfklausel des Berichts beschrieben. Abweichungen von Prüfspezifikation(en) oder Kundenanforderungen sind in der jeweiligen Prüfklausel im Bericht aufgeführt. Test clauses with remark of * are subcontracted to qualified subcontractors and descripted under the respective test clause in the report. Deviations of testing specification(s) or customer requirements are listed in specific test clause in the report. 4 Die Entscheidungsregel für Konformitätserklärungen basierend auf numerischen Messergebnisen in diesem Prüfbericht basiert auf der "Null-Grenzwert-Regel" und der "Einfachen Akzeptanz" gemäß ILAC G8:2019 und IEC Guide 115:2023, es sei denn, in der auf Seite 1 dieses Berichts genannten angewandten Norm ist etwas anderes festgelegt oder vom Kunden gewünscht. Dies bedeutet, dass die Messunsicherheit nicht berücksichtigt wird und daher auch nicht im Prüfbericht angegeben wir…
Text truncated - open the document above for the full version.
Robot Bluetooth Antenna specifications 1. Manufacturer information Manufacturer Name GanZhou Sun&Lynn Circuits Co.,Ltd Manufacturer Address Cobalt Molybdenum rare metal industrial Zone, Zhanggong District, Ganzhou City, Jiangxi Province Antenna Type PIFA Antenna Part Number YC-DZ-BA0304-00-00 2. Electrical characteristics Frequancy Range 2400MHz to 2500MHz Peak Gain 2.0dBi Return Loss > 10dB Impedance 50Ω Polarization Linear 3. Drawing 4. Return loss 5. Radiation patterns
Robot Wi-Fi Antenna specifications 1. Manufacturer information Manufacturer Name Shenzhen Be-comfortable Technology co., ltd. Manufacturer Address C6-1603,Hengfeng Industrial City,No.739,Zhoushi Road, Hezhou Community,Hangcheng Street, Baoan district. Shenzhen Antenna Type Monopole Antenna Part Number YC-DZ-WI0017-00-00 2. Electrical characteristics Frequancy Range 2400MHz to 2500MHz, 5150MHz to 5850MHz Peak Gain 2.4GHz:3.0dBi 5GHz:5dBi Return Loss > 10dB Impedance 50Ω Polarization Linear 3. Drawing 4. Return loss 5. Radiation patterns 2.4GHz 5GHz
Prüfbericht - Produkte Test Report - Products Prüfbericht-Nr.: Test report no.: CN262VO7 002 Auftrags-Nr.: Order no.: 27226076 Seite 1 von 24 Page 1 of 24 Kunden-Referenz-Nr.: Client reference no.: N/A Auftragsdatum: Order date: 2026-03-26 Auftraggeber: Client: Yunjing Intelligence Innovation (Shenzhen) Co., Ltd. Room A2901, Yunzhongcheng, Building 1, Vanke Yuncheng VI, Dashi 2nd Road, Xili Community, Xili Street, Nanshan District, Shenzhen, Guangdong, China Prüfgegenstand: Test item: Robot Vacuum and Mop Bezeichnung / Typ-Nr.: Identification / Type no.: YJCC040 (Trademark: NARWAL) Auftrags-Inhalt: Order content: Test Report Prüfgrundlage: Test specification: CFR Title 47 FCC Part 15: Subpart E Section 15.407 RSS-247 Issue 4 July 2025 RSS-Gen Issue 5 February 2021 Wareneingangsdatum: Date of sample receipt: 2026-04-01 Please refer to Photo Document Prüfmuster-Nr.: Test sample no: A004241255-009/010 A004234101-001/002 Prüfzeitraum: Testing period: 2026-04-23 - 2026-05-11 Ort der Prüfung: Place of testing: TÜV Rheinland (Shenzhen) Co., Ltd. Prüflaboratorium: Testing laboratory: TÜV Rheinland (Shenzhen) Co., Ltd. Prüfergebnis*: Test result*: Pass geprüft von: tested by: X Signed by: Lin Lin genehmigt von: authorized by: X Signed by: Hardy Suo Datum: Date: 2026-05-15 Ausstellungsdatum: Issue date: 2026-05-15 Stellung / Position: Sachverständige(r)/Expert Stellung / Position: Sachverständige(r)/Expert Sonstiges / Other: FCC ID: 2A942YJCC040 IC: 30051-YJCC040 HVIN: YJCC040 This report is for 5GHz Wi-Fi function. Zustand des Prüfgegenstandes bei Anlieferung: Condition of the test item at delivery: Prüfmuster vollständig und unbeschädigt Test item complete and undamaged * Legende: P(ass) = entspricht o.g. Prüfgrundlage(n) F(ail) = entspricht nicht o.g. Prüfgrundlage(n) N/A = nicht anwendbar N/T = nicht getestet * Legend: P(ass) = passed a.m. test specification(s) F(ail) = failed a.m. test specification(s) N/A = not applicable N/T = not tested Dieser Prüfbericht bezieht sich nur auf das o.g. Prüfmuster und darf ohne Genehmigung der Prüfstelle nicht auszugsweise vervielfältigt werden. Dieser Bericht berechtigt nicht zur Verwendung eines Prüfzeichens. This test report only relates to the above mentioned test sample. Without permission of the test center this test report is not permitted to be duplicated in extracts. This test report does not entitle to carry any test mark. TUV Rheinland (Shenzhen) Co., Ltd., 1601-1604, 1801-1804, Tower A Building 2, Shenzhen International Innovation Valley, Dashi 1st Road, Xili Street, Xili Community, Nanshan District, Shenzhen, 518000 Mail: [email protected] · Web: www.tuv.com V101023GCNSR Prüfbericht - Produkte Test Report - Products Prüfbericht-Nr.: CN262VO7 002 Test report no.: Seite 2 von 24 Page 2 of 24 Anmerkungen Remarks 1 Alle eingesetzten Prüfmittel waren zum angegebenen Prüfzeitraum gemäß eines festgelegten Kalibrierungsprogramms unseres Prüfhauses kalibriert. Sie entsprechen den in den Prüfprogrammen hinterlegten Anforderungen. Die Rückverfolgbarkeit der eingesetzten Prüfmittel ist durch die Einhaltung der Regelungen unseres Managementsystems gegeben. Detaillierte Informationen bezüglich Prüfkonditionen, Prüfequipment und Messunsicherheiten sind im Prüflabor vorhanden und können auf Wunsch bereitgestellt werden. The equipment used during the specified testing period was calibrated according to our test laboratory calibration program. The equipment fulfils the requirements included in the relevant standards. The traceability of the test equipment used is ensured by compliance with the regulations of our management system. Detailed information regarding test conditions, equipment and measurement uncertainty is available in the test laboratory and could be provided on request. 2 Wie vertraglich vereinbart, wurde dieses Dokument nur digital unterzeichnet. Der TÜV Rheinland hat nicht überprüft, welche rechtlichen oder sonstigen diesbezüglichen Anforderungen für dieses Dokument gelten. Diese Überprüfung liegt in der Verantwortung des Benutzers dieses Dokuments. Auf Verlangen des Kunden kann der TÜV Rheinland die Gültigkeit der digitalen Signatur durch ein gesondertes Dokument bestätigen. Diese Anfrage ist an unseren Vertrieb zu richten. Eine Umweltgebühr für einen solchen zusätzlichen Service wird erhoben. Informationen zur Verifizierung der Authentizität unserer Dokumente erhalten Sie auf folgender Webseite: go.tuv.com/digital-signature As contractually agreed, this document has been signed digitally only. TUV Rheinland has not verified and unable to verify which legal or other pertaining requirements are applicable for this document. Such verification is within the responsibility of the user of this document. Upon request by its client, TUV Rheinland can confirm the validity of the digital signature by a separate document. Such request shall be addressed to our Sales department. An environmental fee for such additional service will be charged. For information on verifying the authenticity of our documents, please visit the following website: go.tuv.com/digital-signature 3 Prüfklausel mit der Note * wurden an qualifizierte Unterauftragnehmer vergeben und sind unter der jeweiligen Prüfklausel des Berichts beschrieben. Abweichungen von Prüfspezifikation(en) oder Kundenanforderungen sind in der jeweiligen Prüfklausel im Bericht aufgeführt. Test clauses with remark of * are subcontracted to qualified subcontractors and descripted under the respective test clause in the report. Deviations of testing specification(s) or customer requirements are listed in specific test clause in the report. 4 Die Entscheidungsregel für Konformitätserklärungen basierend auf numerischen Messergebnisen in diesem Prüfbericht basiert auf der "Null-Grenzwert-Regel" und der "Einfachen Akzeptanz" gemäß ILAC G8:2019 und IEC Guide 115:2023, es sei denn, in der auf Seite 1 dieses Berichts genannten angewandten Norm ist etwas anderes festgelegt oder vom Kunden gewünscht. Dies bedeutet, dass …
Text truncated - open the document above for the full version.
Prüfbericht - Produkte Test Report - Products Appendix A CN262VO7 002 Page 1 of 150 Appendix A: Test Results of 5GHz Wi-Fi APPENDIX A: TEST RESULTS OF 5GHZ WI-FI ................................................................................................................... 1 APPENDIX A.1: TEST RESULTS OF 26DB BANDWIDTH ................................................................................................................. 2 Test Result..................................................................................................................................................................... 2 Test Graphs ................................................................................................................................................................... 3 APPENDIX A.2: TEST RESULTS OF 99% BANDWIDTH ................................................................................................................. 23 Test Result................................................................................................................................................................... 23 Test Graphs ................................................................................................................................................................. 25 APPENDIX A.3: TEST RESULTS OF 6DB BANDWIDTH ................................................................................................................. 51 Test Result................................................................................................................................................................... 51 Test Graphs ................................................................................................................................................................. 52 APPENDIX A.4: TEST RESULTS OF MAXIMUM OUTPUT POWER ................................................................................................... 59 Test Result................................................................................................................................................................... 59 APPENDIX A.5: TEST RESULTS OF CONDUCTED POWER SPECTRAL DENSITY ................................................................................... 61 Test Result................................................................................................................................................................... 61 Test Graphs ................................................................................................................................................................. 63 APPENDIX A.6: TEST RESULTS OF FREQUENCY STABILITY ........................................................................................................... 89 Test Result................................................................................................................................................................... 89 APPENDIX A.7: TEST RESULTS OF RADIATED SPURIOUS EMISSIONS ............................................................................................. 90 30MHz - 1GHz ............................................................................................................................................................. 90 1GHz - 18GHz .............................................................................................................................................................. 92 APPENDIX A.8: TEST RESULTS OF RADIATED EMISSIONS IN RESTRICTED BANDS ........................................................................... 108 Wi-Fi 802.11 a mode ................................................................................................................................................. 108 Wi-Fi 802.11 ax(HE20) mode .................................................................................................................................... 120 Wi-Fi 802.11 ac(VHT40) mode .................................................................................................................................. 132 APPENDIX A.9: TEST RESULTS OF DYNAMIC FREQUENCY SELECTION (DFS) ................................................................................ 144 DFS Detection Thresholds ......................................................................................................................................... 144 Channel Move Time and Channel Closing Transmission Time .................................................................................. 145 Non-Occupancy Period ............................................................................................................................................. 146 DFS Detection Thresholds for IC ................................................................................................................................ 147 Channel Move Time and Channel Closing Transmission Time for IC ......................................................................... 148 APPENDIX A.10: TEST RESULTS OF CONDUCTED EMISSION ON AC MAINS .................................................................................. 149 Prüfbericht - Produkte Test Report - Products Appendix A CN262VO7 002 Page 2 of 150 Appendix A.1: Test Results of 26dB Bandwidth Test Result TestMode Antenna Channel 26db EBW [MHz] FL[MHz] FH[MHz] Limit[MHz] Verdict 11A Ant1 5180 22.920 5168.320 5191.240 --- PASS 5200 22.600 5188.520 5211.120 --- PASS 5240 22.760 5228.240 5251.000 --- PASS 5260 23.320 5247.440 5270.760 --- PASS 5280 23.440 5267.840 5291.280 --- PASS 5320 23.480 5307.840 5331.320 --- PASS 5500 24.000 5488.240 5512.240 --- PASS 5580 24.360 5567.800 5592.160 --- PASS 5700 24.000 5687.880 5711.880 --- PASS 11N20SISO Ant1 5180 23.200 5169.080 5192.280 --- PASS 5200 22.480 5188.240 5210.720 --- PASS 5240 24.440 5227.640 5252.080 --- PASS 5260 23.480 5247.320 5270.800 --- PASS 5280 24.760 5267…
Text truncated - open the document above for the full version.
Prüfbericht - Produkte Test Report - Products Appendix A CN262VO7 002 Page 61 of 150 Appendix A.5: Test Results of Conducted Power Spectral Density Test Result TestMode Antenna Channel Result [dBm/MHz] Limit[dBm/MHz] Verdict 11A Ant1 5180 1.52 ≤11.00 PASS 5200 2.01 ≤11.00 PASS 5240 1.08 ≤11.00 PASS 5260 1.59 ≤11.00 PASS 5280 0.56 ≤11.00 PASS 5320 1.62 ≤11.00 PASS 5500 -0.37 ≤11.00 PASS 5580 -0.31 ≤11.00 PASS 5700 2.16 ≤11.00 PASS 5745 -0.40 ≤30.00 PASS 5785 -1.16 ≤30.00 PASS 5825 -1.21 ≤30.00 PASS 11N20SISO Ant1 5180 1.83 ≤11.00 PASS 5200 1.84 ≤11.00 PASS 5240 1.37 ≤11.00 PASS 5260 1.65 ≤11.00 PASS 5280 0.73 ≤11.00 PASS 5320 1.05 ≤11.00 PASS 5500 -0.36 ≤11.00 PASS 5580 -0.16 ≤11.00 PASS 5700 1.78 ≤11.00 PASS 5745 -0.01 ≤30.00 PASS 5785 -1.70 ≤30.00 PASS 5825 -1.26 ≤30.00 PASS 11N40SISO Ant1 5190 -0.55 ≤11.00 PASS 5230 -1.61 ≤11.00 PASS 5270 -1.55 ≤11.00 PASS 5310 0.32 ≤11.00 PASS 5510 -3.68 ≤11.00 PASS 5550 -0.56 ≤11.00 PASS 5670 -0.27 ≤11.00 PASS 5755 -1.88 ≤30.00 PASS 5795 -3.02 ≤30.00 PASS 11AC20SISO Ant1 5180 0.01 ≤11.00 PASS 5200 0.84 ≤11.00 PASS 5240 0.28 ≤11.00 PASS 5260 1.97 ≤11.00 PASS 5280 -1.15 ≤11.00 PASS 5320 0.64 ≤11.00 PASS 5500 0.41 ≤11.00 PASS 5580 0.68 ≤11.00 PASS 5700 2.45 ≤11.00 PASS 5745 -0.30 ≤30.00 PASS 5785 -2.16 ≤30.00 PASS 5825 -1.62 ≤30.00 PASS 11AC40SISO Ant1 5190 0.30 ≤11.00 PASS 5230 -0.15 ≤11.00 PASS 5270 -1.56 ≤11.00 PASS 5310 0.54 ≤11.00 PASS 5510 -3.32 ≤11.00 PASS 5550 -1.45 ≤11.00 PASS 5670 0.41 ≤11.00 PASS 5755 -1.88 ≤30.00 PASS 5795 -2.99 ≤30.00 PASS 11AX20SISO Ant1 5180 1.44 ≤11.00 PASS 5200 0.92 ≤11.00 PASS 5240 2.60 ≤11.00 PASS Prüfbericht - Produkte Test Report - Products Appendix A CN262VO7 002 Page 62 of 150 5260 1.26 ≤11.00 PASS 5280 1.30 ≤11.00 PASS 5320 1.38 ≤11.00 PASS 5500 0.91 ≤11.00 PASS 5580 0.40 ≤11.00 PASS 5700 2.39 ≤11.00 PASS 5745 1.19 ≤30.00 PASS 5785 -1.85 ≤30.00 PASS 5825 -1.00 ≤30.00 PASS 11AX40SISO Ant1 5190 -0.29 ≤11.00 PASS 5230 -3.89 ≤11.00 PASS 5270 -1.68 ≤11.00 PASS 5310 -1.87 ≤11.00 PASS 5510 -0.90 ≤11.00 PASS 5550 -3.13 ≤11.00 PASS 5670 -0.95 ≤11.00 PASS 5755 -2.57 ≤30.00 PASS 5795 -2.02 ≤30.00 PASS U-NII 1: Max. e.i.r.p. spectral density= 2.60dBm+5.0dBi= 7.60dBm/MHz, which is less than 10dBm/MHz Note: 1) The Result and Limit Unit is dBm/500 kHz in the band 5.725~5.85 GHz. 2) Antenna gain(G): 5.0dBi for U-NII Band 1. 3) The Duty Cycle Factor and RBW Factor are compensated in the graph. Prüfbericht - Produkte Test Report - Products Appendix A CN262VO7 002 Page 63 of 150 Test Graphs 11A_Ant1_5180 11A_Ant1_5200 11A_Ant1_5240 Prüfbericht - Produkte Test Report - Products Appendix A CN262VO7 002 Page 64 of 150 11A_Ant1_5260 11A_Ant1_5280 11A_Ant1_5320 Prüfbericht - Produkte Test Report - Products Appendix A CN262VO7 002 Page 65 of 150 11A_Ant1_5500 11A_Ant1_5580 11A_Ant1_5700 Prüfbericht - Produkte Test Report - Products Appendix A CN262VO7 002 Page 66 of 150 11A_Ant1_5745 11A_Ant1_5785 11A_Ant1_5825 Prüfbericht - Produkte Test Report - Products Appendix A CN262VO7 002 Page 67 of 150 11N20SISO_Ant1_5180 11N20SISO_Ant1_5200 11N20SISO_Ant1_5240 Prüfbericht - Produkte Test Report - Products Appendix A CN262VO7 002 Page 68 of 150 11N20SISO_Ant1_5260 11N20SISO_Ant1_5280 11N20SISO_Ant1_5320 Prüfbericht - Produkte Test Report - Products Appendix A CN262VO7 002 Page 69 of 150 11N20SISO_Ant1_5500 11N20SISO_Ant1_5580 11N20SISO_Ant1_5700 Prüfbericht - Produkte Test Report - Products Appendix A CN262VO7 002 Page 70 of 150 11N20SISO_Ant1_5745 11N20SISO_Ant1_5785 11N20SISO_Ant1_5825 Prüfbericht - Produkte Test Report - Products Appendix A CN262VO7 002 Page 71 of 150 11N40SISO_Ant1_5190 11N40SISO_Ant1_5230 11N40SISO_Ant1_5…
Text truncated - open the document above for the full version.
442 N BARRANCA AVE. SUITE 180. COVINA, CA 91723 · COVINA, California, 68803 · United States
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15E | 5.18 GHz - 5.24 GHz | 36.00 mW |
| 2 | 15E | 5.26 GHz - 5.32 GHz | 34.80 mW |
| 3 | 15E | 5.50 GHz - 5.70 GHz | 33.40 mW |
| 4 | 15E | 5.75 GHz - 5.83 GHz | 35.60 mW |