FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. JOKARI US INC./
  3. 2A956-11217

2A956-11217Power Friend Solar Rechargeable Battery Bank

JOKARI US INC.
Power Friend Solar Rechargeable Battery Bank - FCC ID 2A956-11217 - JOKARI US INC.
Click to zoom

Application Details

Equipment Class
DCD - Part 15 Low Power Transmitter Below 1705 kHz
Date of Grant
Oct 25, 2023
Application Purpose
Original Equipment
Date of Application
Oct 25, 2023
Equipment Note
Power Friend Solar Rechargeable Battery Bank
Frequency Range
0.11100000 - 0.20500000
Company
JOKARI US INC.
Country
United States

Documents & Files

Select a file to view

Users Manual

↗

Attestation Statements

↗
↗
↗

Cover Letter(s)

↗
↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗
↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

Power Friend Solar Rec hargeable Batter y Bank Pr oduct Features Safety: P ower Friend™ has multiple safeguard tec hnologies to provide over-charge, over-discharge, high temperature, and short circuit protection in all wor king conditions. The 20000 mAh Power Friend™ Solar Rec hargeable Batter y Bank is a high-capacity portable charging station with many f eatures and functions. Make sure to charge the device fully before its fir st use. Use the provided USB cable to charge the power bank. Solar Panels 1.5 V 1.5 V 1.5 V 1.5 V Unfold solar panels from device and lay flat. Allow sun to charge the device. Solar Panels Batter y Type Li-Polymer Batter y Output/Input 5V/3A Output Mode Charging cords USB, Thunderbolt (apple), USB-C, Micro USB+Wireless Input Mode USB + Type-c + Solar Batter y 20000 mAh To avoid possible harm to your safety > This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. > CAN ICES-3 (B) / NMB-3 (B) This Class B digital apparatus complies with Canadian ICES-003.(Cet appareil numĂ©rique de la Classe B conforme Ă  la norme NMB-003 du Canada). > This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radiofrequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: - Reorient or relocate the receiving antenna. - Increase the separation between the equipment and receiver. - Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. - Consult the dealer or an experienced radio/TV technician for help Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. FCC RF Exposure Warning Statement: This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment can be used in portable exposure conditions. This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment can be used in portable exposure conditions. >This device contains licence-exempt transmitter (s)/receiver(s) that comply with Innovation, Science and Economic Development Canada’s licence-exempt RSS(s). Operation is subject to the following two conditions: (1) This device may not cause interference. (2) This device must accept any interference, including interference that may cause undesired operation of the device. L’émetteur/rĂ©cepteur exempt de licence contenu dans le prĂ©sent appareil est conforme aux CNR d’Innovation, Sciences et DĂ©veloppement Ă©conomique Canada applicables aux appareils radio exempts de licence. L’exploitation est autorisĂ©e aux deux conditions suivantes: (1) L' appareil ne doit pas produire de brouillage; (2) L' appareil doit accepter tout brouillage radioĂ©lectrique subi, mĂŞme si le brouillage est susceptible d' en compromettre le fonctionnement. Radio Frequency Exposure Statement for IC: This equipment complies with IC exposure limits set forth for an uncontrolled environment. This equipment can be used in portable exposure conditions. DĂ©claration d'exposition aux radiofrĂ©quences pour IC: Cet Ă©quipement est conforme aux limites d'exposition IC Ă©tablies pour un environnement non contrĂ´lĂ©. Cet Ă©quipement peut ĂŞtre utilisĂ© dans des conditions d'exposition portables. and property , use the product as it was intended and in accordance with the following requirements. If the device becomes swollen, deformed, begins to leak or has significantly reduced capacity, please st op using immediately and dispose of it properly. Do not disassemble, open, crush, puncture, short circuit, submerge in liquid, or expose to extreme temperatures. Improper use may result in batter y failure, fire, over heating, and personal injury. Unplug the device cord after fully charging or discharging to prevent damage to the device. While charging and discharging ensure the device is not covered by clothing, pillows, bedding or other it ems to reduce over heating. This product is not a toy. Please keep out of reach of children. Company name:Jokari US inc. Address: 1220 CHAMPION CIRCLE Suite #100, CARROLLTON, Dallas, Texas 75006, United States Tel: 800-544-3327 E-mail: [email protected] 2023 Warning Wir eless Charging Indicator Light Clear Phone Str ap LED Flash Light USB Input/Output USB Input Features Place device over top of charging circle. Use the clear phone strap to hold device in place. Power Friend™ automatically detects wireless charging enabled devices. Wireless charging Power indicator button/Flash light 25%75%50% 100% The Power Check button is not a Power button. Power Friend™ automatically detects charging and discharging. Power level is shown above device charging port Press and Hold for 1 second to display batter y level Press and Hold for 2 second to turn on/off LED Flash Light Power Indicator Button Flash Light Charging port USB Output USB-C I…

Text truncated - open the document above for the full version.

Attestation Statements

tomorrow's ideas 1220 CHAMPION CIRCLE #100 I CARROLLTON, TX 75006 I T: 800.554.3327 I F: 214.540.9525 I JOKARI.COM S ection 2.911 (d)(7) USA Agent for Service of Process Company name: JOKARI US INC Address: 1220 CHAMPION CIRCLE SUITE #100, CARROLLTON.DALLAS, TEXAS 75006, United states Product Name: Solar rechargeable battery bank FCC ID: 2A956-11217 Model(s):11217 2.911(d}(7) USA Designated Agent for Service of Process We, Jokari US INC ("the applicant") designate Jokari US INC for the purpose of accepting service of process on behalf of the applicant. Applicant consent: We Acknowledge our consent to accept service of process in the United States for matters related to the applicable equipment, and at the physical U.S. address and email address of the designated agent and acknowledge our acceptance of our obligation to maintain an agent for service of process in the United States for no less than one year after either the grantee has permanently terminated all marketing and importation of the applicable equipment within the U.S., or the conclusion of any Commission-related administrative or judicial proceeding involving the equipment, whichever is later. Agent obligation: We Acknowledge our obligation to accept service of process in the United States for matters related to the applicable equipment at our physical U.S. address and email address for no less than one year after either the grantee has permanently terminated all marketing and importation of the applicable equipment within the U.S., or the conclusion of any Commission-related a dministrative or judicial proceeding involving the equipment, whichever is later. USA Agent & Applicant C ompany name: Jokari US INC Address: 1220 CHAMPION CIRCLE SUITE #100, CARROLLTON, DALLAS, TEXAS 75 006, United states FRN: 0033365933 Contact Name: K ent Saller T elephone No: 800.544.3327 Email: [email protected] Signature: ;t;Aďż˝ Title: General Manager Date: 04/24/2023 NOTE 1: An applicant located in the United States may designate itself as the agent for service of process.Reference; Federal Register document 2022- 28263 published on 02/06/23 htto s ://www. f ede r alregister.gov/docum e nts/2023/02/06/2022-28263/orotecting-against-national-security-threats-to-the-communications-suooly-chain­ through-the

Cover Letter(s)

JOKARI US INC. 1220 CHAMPION CIRCLE Suite #100, CARROLLTON, Dallas, Texas 75006, United States Declaration Letter Federal Communications Commission Equipment Authorization Branch 7435 Oakland Mills Road Columbia, MD 21046 6/2/2023 FCC ID: 2A956-11217 Pursuant to KDB 680106 of the JOKARI US INC. Hereby declare our product which is an inductive wireless power transfer applications that meet all of the following requirements are not required to submit a KDB inquiry for devices approved using a PAG for equipment approved using certification to address RF exposure compliance. 1) Power transfer frequency is 0.111-0.205MHz which is less than1 MHz. 2) Output power from each primary coil is equal to 5 watts max. 3) The system consists of one source primary coils, charging one clients. 4) Client device is placed directly in contact with the transmitter. 5) The EUT is a portable device. 6) The aggregate H-field strengths at 15 cm surrounding the device and 20 cm above the top surface from all simultaneous transmitting coils are demonstrated to be less than 50% of the MPE limit. Yours sincerely, Name: Kent Saller Title: General Manager

Cover Letter(s)

Antenna Specification FCC_Confidential

Cover Letter(s)

Letter of Authorization Company: JOKARI US INC. Address: 1220 CHAMPION CIRCLE Suite #100, CARROLLTON, Dallas, Texas 75006, United States Product Name: Power Friend Solar Rechargeable Battery Bank Model Number(s): 11217 Product Description: Power Friend Solar Rechargeable Battery Bank We authorize MiCOM Labs Inc., 575 Boulder Court, Pleasanton, California 94566, USA, to act on our behalf on all matters concerning the certification of above named equipment. We declare that MiCOM Labs Inc. is allowed to forward all information related to the approval and certification of equipment to the regulatory agencies as required and to discuss any issues concerning the approval application. Any and all acts carried out by MiCOM Labs on our behalf shall have the same effect as acts of our own. Signature: Date: Feb. 08, 2023 Name: Kent Saller Title: General Manager Company: JOKARI US INC.

External Photos

Report No.: AGC12495221203AP02 Page 1 of 4 EXTERNAL PHOTOS All VIEW OF EUT (FIGURE 1) All VIEW OF EUT (FIGURE 2) Report No.: AGC12495221203AP02 Page 2 of 4 TOP VIEW OF EUT BOTTOM VIEW OF EUT Report No.: AGC12495221203AP02 Page 3 of 4 FRONT VIEW OF EUT BACK VIEW OF EUT Report No.: AGC12495221203AP02 Page 4 of 4 LEFT VIEW OF EUT RIGHT VIEW OF EUT ****************************************End of Report****************************************

ID Label/Location Info

50mm*30mm

Internal Photos

Report No.: AGC12495221203AP02 Page 1 of 6 INTERNAL PHOTOS PORT VIEW OF EUT (FIGURE 1) OPEN VIEW OF EUT (FIGURE 1) Report No.: AGC12495221203AP02 Page 2 of 6 OPEN VIEW OF EUT (FIGURE 2) VIEW OF BATTERY Report No.: AGC12495221203AP02 Page 3 of 6 INTERNAL VIEW OF EUT (FIGURE 1) INTERNAL VIEW OF EUT (FIGURE 2) Antenna Report No.: AGC12495221203AP02 Page 4 of 6 INTERNAL VIEW OF EUT (FIGURE 3) INTERNAL VIEW OF EUT (FIGURE 4) Report No.: AGC12495221203AP02 Page 5 of 6 INTERNAL VIEW OF EUT (FIGURE 5) INTERNAL VIEW OF EUT (FIGURE 6) Report No.: AGC12495221203AP02 Page 6 of 6 INTERNAL VIEW OF EUT (FIGURE 7) ****************************************End of Report**************************************** 50mm

RF Exposure Info

Page 1 of 14 RF Exposure Report Report No.: AGC12495221203FH01 FCC ID : 2A956-11217 APPLICATION PURPOSE : Original Equipment PRODUCT DESIGNATION : Power Friend Solar Rechargeable Battery Bank BRAND NAME : Jokari MODEL NAME : 11217 APPLICANT : JOKARI US INC. DATE OF ISSUE : Jan. 03, 2023 STANDARD(S) : KDB680106 D01 RF Exposure Wireless Charging Base App v03r01 REPORT VERSION : V 1.0 Attestation of Global Compliance (Shenzhen) Co., Ltd Report No.: AGC12495221203FH01 Page 2 of 14 REPORT REVISE RECORD Report Version Revise Time Issued Date Valid Version Notes V1.0 / Jan. 03, 2023 Valid Initial Release Report No.: AGC12495221203FH01 Page 3 of 14 TABLE OF CONTENTS 1. GENERAL INFORMATION .............................................................................................................................. 4 2. PRODUCT INFORMATION .............................................................................................................................. 5 2.1. PRODUCT TECHNICAL DESCRIPTION ............................................................................................... 5 2.2. TEST FREQUENCY LIST ....................................................................................................................... 5 3. TEST ENVIRONMENT ..................................................................................................................................... 6 3.1. ADDRESS OF THE TEST LABORATORY ............................................................................................. 6 3.2. TEST FACILITY ...................................................................................................................................... 6 3.3. ENVIRONMENTAL CONDITIONS ......................................................................................................... 7 3.4. MEASUREMENT UNCERTAINTY ......................................................................................................... 7 3.5. LIST OF EQUIPMENTS USED .............................................................................................................. 7 4. EQUIPMENT USED IN TESTED SYSTEM ...................................................................................................... 8 5. DESCRIPTION OF TEST MODES ................................................................................................................... 8 6. RF EXPOSURE MEASUREMENT ................................................................................................................... 9 6.1. REFER EVALUATION METHOD ............................................................................................................ 9 6.2. TEST LIMITS .......................................................................................................................................... 9 6.3. MEASUREMENT SETUP ..................................................................................................................... 10 6.4. MEASUREMENT PROCEDURE .......................................................................................................... 11 6.5. MEASUREMENT RESULTS................................................................................................................. 11 APPENDIX A: PHOTOGRAPHS OF TEST SETUP .......................................................................................... 14 Report No.: AGC12495221203FH01 Page 4 of 14 1. GENERAL INFORMATION Applicant JOKARI US INC. Address 1220 CHAMPION CIRCLE Suite #100, CARROLLTON, Dallas, Texas 75006, United States Manufacturer JOKARI US INC. Address 1220 CHAMPION CIRCLE Suite #100, CARROLLTON, Dallas, Texas 75006, United States Product Designation Power Friend Solar Rechargeable Battery Bank Brand Name Jokari Test Model 11217 Deviation from Standard No any deviation from the test method Date of Receipt Dec. 14, 2022 Date of Test Dec. 14, 2022 to Jan. 03, 2023 Test Result Pass Prepared By Alan Duan (Project Engineer) Jan. 03, 2023 Reviewed By Calvin Liu (Reviewer) Jan. 03, 2023 Approved By Max Zhang (Authorized Officer) Jan. 03, 2023 Report No.: AGC12495221203FH01 Page 5 of 14 2. PRODUCT INFORMATION 2.1. PRODUCT TECHNICAL DESCRIPTION Equipment Specification WPT Operation Frequency 111-205KHz Hardware Version V1.0 Software Version V1.0 Modulation Type FSK Number of channels 1 Field Strength of Fundamental 67.11dBuV/m (Max) Antenna Designation Coil Antenna Antenna Gain 0dBi EUT Power Supply DC 3.7V battery Power Supply Input: Type-c: 5V3.0A, MICRO: 5V2.0A Output: Type-c: 5V3.0A, USB1: 5V3.0A, USB2: 5V3.0A Wireless Charging Output Power 5W Adapter Information N/A 2.2. TEST FREQUENCY LIST Frequency Band Channel Number Test Frequency 111~205KHz 01 113.6kHz Report No.: AGC12495221203FH01 Page 6 of 14 3. TEST ENVIRONMENT 3.1. ADDRESS OF THE TEST LABORATORY Laboratory: Attestation of Global Compliance (Shenzhen) Co., Ltd. Address: 1-2/F, Building 19, Junfeng Industrial Park, Chongqing Road, Heping Community, Fuhai Street, Bao'an District, Shenzhen, Guangdong, China 3.2. TEST FACILITY The test facility is recognized, certified, or accredited by the following organizations: CNAS-Lab Code: L5488 Attestation of Global Compliance (Shenzhen) Co., Ltd. has been assessed and proved to be in compliance with CNAS-CL01 Accreditation Criteria for Testing and Calibration Laboratories (identical to ISO/IEC17025: 2017 General Requirements) for the Competence of Testing and Calibration Laboratories. A2LA-Lab Cert. No.: 5054.02 Attestation of Global Compliance (Shenzhen) Co., Ltd. EMC Laboratory has been accredited by A2LA for technical competence in the field of electrical testing, and proved to be in compliance with ISO/IEC 17025: 2017 General Requirements for the Competence of Testing and Calibration Laboratories and any additional program requirements in the identified field of testing. FCC-Registration No.: 975832 Attestation of Global Compliance (Shenzhen) Co., Ltd. EMC Laboratory has been registered and fully …

Text truncated - open the document above for the full version.

Test Report

Page 1 of 30 FCC Test Report Report No.: AGC12495221203FE10 FCC ID : 2A956-11217 APPLICATION PURPOSE Original Equipment PRODUCT DESIGNATION : Power Friend Solar Rechargeable Battery Bank BRAND NAME : Jokari MODEL NAME : 11217 APPLICANT : JOKARI US INC. DATE OF ISSUE : Jan. 03, 2023 STANDARD(S) : FCC Part 15 Subpart C REPORT VERSION : V 1.0 Attestation of Global Compliance (Shenzhen) Co., Ltd Report No.: AGC12495221203FE10 Page 2 of 30 REPORT REVISE RECORD Report Version Revise Time Issued Date Valid Version Notes V1.0 / Jan. 03, 2023 Valid Initial Release Report No.: AGC12495221203FE10 Page 3 of 30 TABLE OF CONTENTS 1. GENERAL INFORMATION .............................................................................................................................. 5 2. PRODUCT INFORMATION .............................................................................................................................. 6 2.1 PRODUCT TECHNICAL DESCRIPTION ................................................................................................ 6 2.2 TEST FREQUENCY LIST ........................................................................................................................ 6 2.3 RELATED SUBMITTAL(S) / GRANT (S) ................................................................................................. 7 2.4 TEST METHODOLOGY .......................................................................................................................... 7 2.5 SPECIAL ACCESSORIES ....................................................................................................................... 7 2.6 EQUIPMENT MODIFICATIONS .............................................................................................................. 7 2.7 ANTENNA REQUIREMENT .................................................................................................................... 7 3. TEST ENVIRONMENT ..................................................................................................................................... 8 3.1 ADDRESS OF THE TEST LABORATORY .............................................................................................. 8 3.2 TEST FACILITY ....................................................................................................................................... 8 3.3 ENVIRONMENTAL CONDITIONS........................................................................................................... 9 3.4 MEASUREMENT UNCERTAINTY .......................................................................................................... 9 3.5 LIST OF EQUIPMENTS USED ............................................................................................................. 10 4.SYSTEM TEST CONFIGURATION ................................................................................................................. 11 4.1 EUT CONFIGURATION ......................................................................................................................... 11 4.2 EUT EXERCISE ..................................................................................................................................... 11 4.3 CONFIGURATION OF TESTED SYSTEM ............................................................................................ 11 4.4 EQUIPMENT USED IN TESTED SYSTEM........................................................................................... 11 4.5 SUMMARY OF TEST RESULTS ........................................................................................................... 12 5. DESCRIPTION OF TEST MODES ................................................................................................................. 13 6. FIELD STRENGTH OF FUNDAMENTAL ...................................................................................................... 14 6.1 PROVISIONS APPLICABLE .................................................................................................................. 14 6.3 FIELD STRENGTH CALCULATION ...................................................................................................... 16 6.4 MEASUREMENT SETUP (BLOCK DIAGRAM OF CONFIGURATION) ............................................... 17 6.5 MEASUREMENT RESULTS.................................................................................................................. 18 7. 20 DB BANDWIDTH ....................................................................................................................................... 24 7.1 PROVISIONS APPLICABLE .................................................................................................................. 24 7.2 MEASUREMENT PROCEDURE ........................................................................................................... 24 7.3 MEASUREMENT SETUP (BLOCK DIAGRAM OF CONFIGURATION) ............................................... 24 7.4 MEASUREMENT RESULTS.................................................................................................................. 25 8. AC POWER LINE CONDUCTED EMISSION TEST ...................................................................................... 26 8.1 LIMITS OF LINE CONDUCTED EMISSION TEST ............................................................................... 26 Report No.: AGC12495221203FE10 Page 4 of 30 8.2 MEASUREMENT SETUP (BLOCK DIAGRAM OF CONFIGURATION) ............................................... 26 8.3 PRELIMINARY PROCEDURE OF LINE CONDUCTED EMISSION TEST .......................................... 27 8.4 FINAL PROCEDURE OF LINE CONDUCTED EMISSION TEST ........................................................ 27 8.5 MEASUREMENT RESULTS.................................................................................................................. 28 APPENDIX A: PHOTOGRAPHS OF TEST SETUP ........................................................................…

Text truncated - open the document above for the full version.

Test Report

3 1.电路图/CIRCUITDIAGRAM 单位:MM 2.外形图/OUTSIDE DIAGRAM 7 Adhesive backing Unit: MM

Test Setup Photos

Report No.: AGC12495221203AP01 Page 1 of 7 TEST SETUP PHOTOS RADIATED EMISSION TEST SETUP BELOW 30MHz RADIATED EMISSION TEST SETUP BELOW 1GHz Report No.: AGC12495221203AP01 Page 2 of 7 AC POWER LINE CONDUCTED TEST SETUP Report No.: AGC12495221203AP01 Page 3 of 7 RF HEALTH ASSESSMENT TEST PHOTOS Mobile H-Field & E-Field Strength_ Position A H-Field & E-Field Strength_ Position B Report No.: AGC12495221203AP01 Page 4 of 7 H-Field & E-Field Strength_ Position C H-Field & E-Field Strength_ Position D Report No.: AGC12495221203AP01 Page 5 of 7 H-Field & E-Field Strength_ Position E Portable H-Field & E-Field Strength_ Position A Report No.: AGC12495221203AP01 Page 6 of 7 H-Field & E-Field Strength_ Position B H-Field & E-Field Strength_ Position C Report No.: AGC12495221203AP01 Page 7 of 7 H-Field & E-Field Strength_ Position D H-Field & E-Field Strength_ Position E ****************************************End of Report*************************************

Contact Information

Applicant

Kent Saller
[email protected]800-544-3327Fax: /

Technical Contact

JOKARI US INC.
[email protected]

United States

Test Firm

Attestation of Global Compliance (Shenzhen) Co., LDoris Li
[email protected]+86-755-25234088

Technical Specifications

#Rule PartsFrequency RangePower Output
115C0.111 MHz - 0.205 MHz-
Confidentiality
Long Term