Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
06/02/2023, 13:26Setup & Use – Rithum Help Centre https://support.rithumhome.com/hc/en-gb/articles/4405491941009-Setup-Use1/10 Rithum Help Centre > Technical Guides Setup & Use 1 year ago· Updated Unfollow Setup Once you have installed your SmartSwitch Lite as per the installation instructions, there is some basic setup to do. You can also watch our setup demo below from our YouTube channel: Rithum SmartSwitch Lite Con guration | Software Version Rithum SmartSwitch Lite Con guration | Software Version ...... Search Articles in this section 06/02/2023, 13:26Setup & Use – Rithum Help Centre https://support.rithumhome.com/hc/en-gb/articles/4405491941009-Setup-Use2/10 Note on waking the screen: If you have an early version of software on your SmartSwitch (with batch number 202104 printed on the device label), then waking the screen may require a hold instead of a tap. Once connected to Wi-Fi and updated, it will then be a tap to wake. Note on software updates: After connecting your SmartSwitch to Wi-Fi (and the internet), your switch may update its software from the cloud. It is recommended to wait a few minutes after first connecting to the internet for this to happen so you don't have to configure the device twice. Power-up When power is applied, SmartSwitch Lite should boot up automatically, no action is required. After a few seconds to a minute, SmartSwitch will load into the Scenes screen. If it is the first boot then most likely you will have a WiFi error as you have not configured the network yet. Navigation SmartSwitch Lite has three main screens: 1. Scenes screen (default) 2. Audio screen 06/02/2023, 13:26Setup & Use – Rithum Help Centre https://support.rithumhome.com/hc/en-gb/articles/4405491941009-Setup-Use3/10 3. Settings screen Navigation between these screens is done via the Tabs at the top and bottom of the screen which can either be tapped or swiped. The Bottom Tab on the Scenes screen navigates to the Audio screen where the Top Tab then navigates back to the Scenes screen. The Top Tab of the Scenes screen navigates to the Settings screen where the Bottom Tab then navigates back to the Scenes screen. Settings Screen Go to the Settings screen by tapping or swiping the Top Tab on the Scenes screen. Wi-Fi Setup The first thing to configure is the Wi-Fi which SmartSwitch Lite uses for all communications. It is important to ensure a good wifi connection and therefore a non-ISP supplied router/network is highly recommended with additional access points as appropriate to provide adequate coverage. To get started, tap Network from the Settings menu. SmartSwitch Lite will then scan available Wi-Fi networks and show a list of them. Now simply tap on the network you want to connect to and enter the key. 06/02/2023, 13:26Setup & Use – Rithum Help Centre https://support.rithumhome.com/hc/en-gb/articles/4405491941009-Setup-Use4/10 If you can't see a network that you are expecting to see, then tap to go back and then tap Network again. This should rescan available networks. Location The Location setting is used to set weather information that is then displayed on the Top Tab. Simply tap Location, then enter your postcode (currently UK only) and tap . If successful, the weather icon on the Top Tab on the Scenes screen should update after a few seconds. If the postcode doesn't work after a couple of tries, please check the format. In some cases, it might be necessary to use a nearby postcode if the one you have entered is not in the database we use (e.g. it's a new postcode). Changing timezones is not currently supported. Philips Hue 06/02/2023, 13:26Setup & Use – Rithum Help Centre https://support.rithumhome.com/hc/en-gb/articles/4405491941009-Setup-Use5/10 SmartSwitch Lite communicates with your Philips Hue system via your Hue Bridge. Currently only one bridge is supported per SmartSwitch Lite at any one time, although you are of course free to still have multiple Hue Bridges within your Hue system and to configure each SmartSwitch Lite to work with a different Bridge. To get started, simply tap Philips Hue in the Settings menu. This will scan your network for available bridges and show them in a list. Note: Philips Hue Bridge discovery currently requires an internet connection. If your system does not have internet connectivity, then please get the IP address from the Philips Hue app or use a network scanner and manually enter the bridge IP address as explained below. Tap on the Hue bridge that you would like to pair with. If you don't know which one, then you can find out through the Hue app. Alternatively, you can tap Enter IP Address... and manually input an IP address for a bridge. When a bridge has successfully been paired, there will be a next to the bridge IP address briefly and the screen will progress to the room selection. 06/02/2023, 13:26Setup & Use – Rithum Help Centre https://support.rithumhome.com/hc/en-gb/articles/4405491941009-Setup-Use6/10 Currently, SmartSwitch Lite only supports the selection of one Room or Zone. This is the Room/Zone that will be used for the On/Off scene that is shown on the Scenes screen which mimics the On/Off button within the Room/Zone in the Hue app (i.e. if any lights in the Room/Zone are on, then Off is shown, otherwise On is shown). It is also the Room/Zone from which you can select the other scenes to display on the Scenes screen (shown in the next step). If you want to control lights across multiple Rooms then you can create a Zone in the Hue app that contains lights from both Rooms. Within this Zone, you can create custom Scenes that have different states for different rooms or lights. Select the Room/Zone you want to pair the SmartSwitch Lite with and the screen then advances to the Scenes List. 06/02/2023, 13:26Setup & Use – Rithum Help Centre https://support.rithumhome.com/hc/en-gb/articles/4405491941009-Setup-Use7/10 The Scenes List allows you to select which scenes to show on the Scenes screen. You can select up to seven (7) scenes whi…
Text truncated - open the document above for the full version.
VioletUltraLtd 2.911(d)(5)(i)EquipmentTypeAttestationv1.2 Section2.911(d)(5)(i)Certification–EquipmentType Companyname:VioletUltraLtd Address:128CityRoad,London,EC1V2NX,UK ProductName:RithumSwitch FCCID:2A96X-RS-01 Model(s):RS-01-BL,RS-YY-XX(anyversionRS-YY-XX,where##isanumberandXXis alphanumeric) 2.911(d)(5)(i)EquipmentType We,[VioletUltraLtd](“theapplicant”)certifythattheequipmentforwhichauthorizationissought throughcertificationisnot: Prohibitedfromreceivinganequipmentauthorizationpursuantto§2.903;oftheFCCrules. Identifiedasanequipmenttypeinthe“CoveredList” NOTE1 Yourssincerely, Name:RyanOvensDate:2023-03-20 TitleandCompanyname:Manager/VioletUltraLtd NOTE1 “CoveredList ” ;istheListofEquipmentandServicesCoveredBySection2ofTheSecureNetworksAct,availableat https://www.fcc.gov/supplychain/coveredlist References; 1)986446D01CoveredEquipmentv01 https://apps.fcc.gov/oetcf/kdb/forms/FTSSearchResultPage.cfm?switch=P&id=325672 2)FederalRegisterdocument2022-28263publishedon02/06/23 https://www.federalregister.gov/documents/2023/02/06/2022-28263/protecting-against-national-security-threats-to-the-com munications-supply-chain-through-the
VioletUltraLtd 2.911(d)(5)(ii)ApplicantAttestationv1.2 Section2.911(d)(5)(ii)Certification–Applicant(CoveredList) Companyname:VioletUltraLtd Address:128CityRoad,London,EC1V2NX,UK ProductName:RithumSwitch FCCID:2A96X-RS-01 Model(s):RS-01-BL,RS-YY-XX(anyversionRS-YY-XX,where##isanumberandXXis alphanumeric) 2.911(d)(5)(ii)Applicantfiling We,[VioletUltraLtd](“theapplicant”)certifythat,asofthedateofthefilingoftheapplication,the applicantisnotidentified NOTE1 onthe“CoveredList” NOTE2 ,establishedpursuantto §1.50002ofthischapter,asanentityproducingcoveredcommunicationsequipment. Yourssincerely, Name:RyanOvensDate:2023-03-20 TitleandCompanyname:Manager/VioletUltraLtd NOTE1 Deleteoptionnotapplicabletothisapplication. NOTE2 “CoveredList ” ;istheListofEquipmentandServicesCoveredBySection2ofTheSecureNetworksAct,availableat https://www.fcc.gov/supplychain/coveredlist
VioletUltraLtd AgentAuthorization Companyname:VioletUltraLtd Address:128CityRoad,London,EC1V2NX,UK ProductName:RithumSwitch ModelNumber(s):RS-01-BL,RS-YY-XX(anyversionRS-YY-XX,where##isa numberandXXisalphanumeric) ProductDescription:RithumSwitch WeauthorizeMiCOMLabsInc.,575BoulderCourt,Pleasanton,California94566,USA, toactonourbehalfonallmattersconcerningthecertificationofabovenamed equipment. WedeclarethatMiCOMLabsInc.isallowedtoforwardallinformationrelatedtothe approvalandcertificationofequipmenttotheregulatoryagenciesasrequiredandto discussanyissuesconcerningtheapprovalapplication.Anyandallactscarriedoutby MiCOMLabsonourbehalfshallhavethesameeffectasactsofourown. Signature:Date:2023.03.20 Name:RyanOvens Title:Manager Company:VioletUltraLtd
VioletUltraLtd ModelDifferent Modelname:RithumSwitch FCCID:2A96X-RS-01 Modelnumber:RS-01-BL,RS-YY-XX(anyversionRS-YY-XX,whereYYisanumberandXX isalphanumeric) Allmodel’sthefunction,softwareandelectriccircuitarethesame,exceptthecolour. Name:RyanOvens Date:2023-03-20 Title:Manager Signatureofapplicant:
VioletUltraLtd OfficeofEngineeringTechnology FederalCommunicationsCommission 7435OaklandMillsRoad Columbia,MD21046 USA Date:2023.03.20 Subject;RequestforConfidentiality FCCID:2A96X-RS-01 ToWhomItMayConcern, PursuanttotheprovisionsoftheCommission’srulesTitle47Sections§0.457and§0.459,we arerequestingtheCommissiontowithholdthefollowingattachment(s)asconfidential documentsfrompublicdisclosureindefinitely. Thesedocumentscontaindetailedsystemandequipmentdescriptionsandareconsideredas proprietaryinformationinoperationoftheequipment.Thepublicdisclosureofthesedocuments mightbeharmfultoourcompanyandwouldgivecompetitorsanunfairadvantageinthemarket. SchematicDiagram BlockDiagram PartsList OperationalDescription Tune-upProcedure Inadditionaltoabovementioneddocuments,inordertocomplywiththemarketingregulations inTitle47CFR§2.803andtheimportationrulesinTitle47CFR§2.1204,whileensuringthat businesssensitiveinformationremainsconfidentialuntiltheactualmarketingofnewly authorizeddevices,werequestShortTermConfidentialityofthefollowingattachment(s); ExternalPhotos TestSetupPhotos InternalPhotos UserManual For45days,pursuanttoPublicNoticeDA04-1705. OR For180dayspursuanttoKDB726920D01. Itisourunderstandingthatallmeasurementtestreports,FCCIDlabelformatand correspondenceduringthecertificationreviewprocesscannotbegrantedasconfidential documentsandthisinformationwillbeavailableforpublicreviewoncethegrantofequipment authorizationisissued. Sincerely, Signature: Name:RyanOvens Title:Manager
VioletUltraLtd OfficeofEngineeringTechnology FederalCommunicationsCommission 7435OaklandMillsRoad Columbia,MD21046 USA Date:2023.03.20 Subject;RequestforConfidentiality FCCID:2A96X-RS-01 ToWhomItMayConcern, PursuanttotheprovisionsoftheCommission’srulesTitle47Sections§0.457and§0.459,we arerequestingtheCommissiontowithholdthefollowingattachment(s)asconfidential documentsfrompublicdisclosureindefinitely. Thesedocumentscontaindetailedsystemandequipmentdescriptionsandareconsideredas proprietaryinformationinoperationoftheequipment.Thepublicdisclosureofthesedocuments mightbeharmfultoourcompanyandwouldgivecompetitorsanunfairadvantageinthemarket. SchematicDiagram BlockDiagram PartsList OperationalDescription Tune-upProcedure Inadditionaltoabovementioneddocuments,inordertocomplywiththemarketingregulations inTitle47CFR§2.803andtheimportationrulesinTitle47CFR§2.1204,whileensuringthat businesssensitiveinformationremainsconfidentialuntiltheactualmarketingofnewly authorizeddevices,werequestShortTermConfidentialityofthefollowingattachment(s); ExternalPhotos TestSetupPhotos InternalPhotos UserManual For45days,pursuanttoPublicNoticeDA04-1705. OR For180dayspursuanttoKDB726920D01. Itisourunderstandingthatallmeasurementtestreports,FCCIDlabelformatand correspondenceduringthecertificationreviewprocesscannotbegrantedasconfidential documentsandthisinformationwillbeavailableforpublicreviewoncethegrantofequipment authorizationisissued. Sincerely, Signature: Name:RyanOvens Title:Manager
ExternalPhotos
InternalPhotos Wifi/BTAntenna
FCCID:2A96X-RS-01 RFExposureEvaluation Limits Thecriterialistedinthefollowingtableshallbeusedtoevaluatetheenvironmentimpactofhumanexposure toradiofrequency(RF)radiationasspecifiedin1.1307(b) LimitsforMaximumPermissibleExposure(MPE) Frequencyrange (MHz) Electricfield strength (V/m) Magneticfieldstrength (A/m) Powerdensity (mW/cm 2 ) Averagingtime (minutes) (A)LimitsforOccupational/ControlledExposures 0.3–3.06141.63*(100)6 3.0–301842/f4.89/f*(900/f 2 )6 30–30061.40.1631.06 300–1500f/3006 1500–100,00056 (B)LimitsforGeneralPopulation/UncontrolledExposure 0.3–1.346141.63*(100)30 1.34–30824/f2.19/f*(180/f 2 )30 30–30027.50.0730.230 300–1500f/150030 1500–100,0001.030 f=frequencyinMHz Friistransmissionformula:Pd=(Pout*G)/(4*pi*r 2 ) Where Pd=powerdensityinmW/cm 2 ,Pout=outputpowertoantennainmW; G=gainofantennainlinearscale,Pi=3.1416; R=distancebetweenobservationpointandcenteroftheradiatorincm PdidthelimitofMPE,1mW/cm 2 .Ifweknowthemaximumgainoftheantennaandthetotalpowerinputto theantenna,throughthecalculation,wewillknowthedistancerwheretheMPElimitisreached. TestProcedure SoftwareprovidedbyclientenabledtheEUTtotransmitandreceivedataatlowest,middleandhighest channelindividually. TestResultofRFExposureEvaluation Modulation Output powerto antenna (dBm) Outputpower toantenna (mW) PowerDensity atR=20cm (mW/cm 2 ) Limit (mW/cm 2 ) Result BTGFSK -0.560.87900.0002481.0PASS -0.500.89130.0002521.0PASS -0.350.92260.0002601.0PASS Wifi 802.11b 17.6958.74890.0165861.0PASS 17.2653.21080.0150221.0PASS 17.2152.60170.0148501.0PASS 802.11g 15.7837.84430.0106841.0PASS 15.3634.35580.0096991.0PASS 15.6536.72820.0103691.0PASS 802.11n20 14.6429.10720.0082171.0PASS 14.1225.82260.0072901.0PASS 14.5228.31390.0079931.0PASS 802.11n40 13.2821.28140.0060081.0PASS 13.0220.04470.0056591.0PASS 13.1120.46440.0057771.0PASS Remark:antennagain=1.52dBi
地址:深圳市宝安71区留仙一路二巷26号L栋5楼5D传真0755-85263741 深圳市天联凌科技有限公司 ShenzhenSKYLinkTechnologyCo.,Ltd 天线规格承认书 编号:SLSOA2023020801 客户名称:南尔智能 项目名称:86S 产品描述:(二合一天线)PCB硬板黑色,1.13线径,70mm线长,一代端子 产品料号:86S.C113.70B.1 板本:V2.0 日期:20 23 -02 -08 客户 工程采购承认 天联凌 研发工程审核 地址:深圳市宝安71区留仙一路二巷26号L栋5楼5D传真0755-85263741 规格概述 电特性 频率 2400MHz~2500MHz 电压驻波比<2.0 效率>40% 增益1.52 dbi 阻抗50欧姆 极化方式线极化 材料和机械特性 材料 PCB 硬板 线材类型线径1.13 端子类型一代端子 图纸尺寸详见图纸 丝印方式黑底白字 环境特性 储存温度 - 30 ̊C ~ + 85 ̊C FPC焊接温度280±5°C浸渍时间:10秒 射频线焊接温度 320 ± 5 °C 2-3 秒 地址:深圳市宝安71区留仙一路二巷26号L栋5楼5D传真0755-85263741 测试设备与条件 1.网络分析仪: Agilent8753DAgilent5071B 通讯测试设备: AgilentE5515CR&SCMW500 2.3D测试系统 A 0.03 0.02 0.04 0~10 ±0.05 10~18 ±0.10 18~30 ±0.12 ∅ 0.02 30~40 ±0.15 Remark Rev Date Third Angle New drawing Description 40~ ±0.20 1234 Approved by D C B 5678 A 12345678 Part No. Date Designed by Checked by Scale Rev mm Location Project Material Part Name Unit RF MD A Angle ±0.5° 1:1 D C B A 深 圳 天 联 凌 科 技 有 限 公 司 SHEN ZHEN SKYLink CO.,LTD RoHS P G Compliant DWG No. 2023-02-08 二合一天线 86S.C113.70B.1 Remark Colour Material PartName No. 1 黑色 PCB 2 同轴线镀银铜丝 黑色 天线 注: 1."*"为重点尺寸 ; 2.未标注尺寸请依图纸; 3.Pb、Hg、Cr+6、PBBs、PBDEs各项小于1000PPM,Cd小于100PPM。 由 Autodesk 教育版产品制作 由 Autodesk 教育版产品制作 由Autodesk教育版产品制作 由 Autodesk 教育版产品制作 地址:深圳市宝安71区留仙一路二巷26号L栋5楼5D传真0755-85263741 匹配电路 无源测试报告 S11图 原主板匹配电路不变 模块端 天线端 地址:深圳市宝安71区留仙一路二巷26号L栋5楼5D传真0755-85263741 2.4G 效率/增益
ProjectNo.:ZKT-230213L0661E-02 Page 1 of 51 FCCTESTREPORT FCCID:2A96X-RS-01 ReportNumber...................................:ZKT-2230213L0661E-02 DateofTest.......................................................: Feb.12,2023toMar.6,2023 Dateofissue.........................................: Mar.6,2023 Totalnumberofpages .......................... 51 TestResult ............................................ : PASS TestingLaboratory............................: ShenzhenZKTTechnologyCo.,Ltd. Address...............................................: 1/F,No.101,BuildingB,No.6,TangweiCommunityIndustrial Avenue,FuhaiStreet,Bao'anDistrict,Shenzhen,China Applicant'sname.............................:VioletUltraLtd Address...............................................:128CityRoad,London,EC1V2NX,UK Manufacturer'sname ...................... :VioletUltraLtd Address...............................................:128CityRoad,London,EC1V2NX,UK Testspecification: Standard ................................................ : FCCCFRTitle47Part15SubpartCSection15.247 ANSIC63.10:2013 Testprocedure.....................................: / Non-standardtestmethod................:N/A TestReportFormNo. ....................... : TRF-EL-110_V0 TestReportForm(s)Originator ..... : ZKTTesting MasterTRF ........................................ : Dated:2020-01-06 ThisdevicedescribedabovehasbeentestedbyZKT,andthetestresultsshowthattheequipmentunder test(EUT)isincompliancewiththeFCCrequirements.Anditisapplicableonlytothetestedsample identifiedinthereport. Thisreportshallnotbereproducedexceptinfull,withoutthewrittenapprovalofZKT,thisdocumentmay bealteredorrevisedbyZKT,personalonly,andshallbenotedintherevisionofthedocument. Productname.....................................: RithumSwitch Trademark...........................................: RITHUM, Model/Typereference.........................: RS-01-BL, SerialmodelNo...................................:RS-YY-XX(anyversionRS-YY-XX,whereYYisanumberandXXis alphanumeric) Ratings..................................................:AC100-240V,50-60Hz,0.26AMaxor12-30VDC,1AMax ProjectNo.:ZKT-2302133L0661E Page 2 of 51 Testingprocedureandtestinglocation: TestingLaboratory.......................................:ShenzhenZKTTechnologyCo.,Ltd. Address............................................................:1/F,No.101,BuildingB,No.6,TangweiCommunity IndustrialAvenue,FuhaiStreet,Bao'anDistrict, Shenzhen,China AlenHe Testedby(name+signature).......................: JoeLiu Reviewer(name+signature).......................: LakeXie Approved(name+signature).......................: ProjectNo.:ZKT-2302133L0661E Page 3 of 51 TableofContents Page 1.VERSION5 2.SUMMARYOFTESTRESULTS6 2.1TESTFACILITY7 2.2MEASUREMENTUNCERTAINTY7 3.GENERALINFORMATION8 3.1GENERALDESCRIPTIONOFEUT8 3.2DESCRIPTIONOFTESTMODES9 3.3BLOCKDIGRAMSHOWINGTHECONFIGURATIONOFSYSTEMTESTED9 3.4DESCRIPTIONOFSUPPORTUNITS(CONDUCTEDMODE)9 3.5EQUIPMENTSLISTFORALLTESTITEMS11 4.EMCEMISSIONTEST13 4.1CONDUCTEDEMISSIONMEASUREMENT13 4.1.1POWERLINECONDUCTEDEMISSIONLIMITS13 4.1.2TESTPROCEDURE13 4.1.3DEVIATIONFROMTESTSTANDARD13 4.1.4TESTSETUP14 4.1.5EUTOPERATINGCONDITIONS14 4.1.6TESTRESULT15 4.2RADIATEDEMISSIONMEASUREMENT17 4.2.1RADIATEDEMISSIONLIMITS17 4.2.2TESTPROCEDURE17 4.2.3DEVIATIONFROMTESTSTANDARD18 4.2.4TESTSETUP18 4.2.5EUTOPERATINGCONDITIONS19 4.2.6TESTRESULTS19 5.RADIATEDBANDEMISSIONMEASUREMENT24 5.1TESTREQUIREMENT:24 5.2TESTPROCEDURE24 5.3DEVIATIONFROMTESTSTANDARD24 5.4TESTSETUP25 5.5EUTOPERATINGCONDITIONS25 5.6TESTRESULT26 6.POWERSPECTRALDENSITYTEST28 6.1APPLIEDPROCEDURES/LIMIT28 6.2TESTPROCEDURE28 6.3DEVIATIONFROMSTANDARD28 6.4TESTSETUP28 6.5EUTOPERATIONCONDITIONS28 ProjectNo.:ZKT-2302133L0661E Page 4 of 51 6.6TESTRESULT29 7.CHANNELBANDWIDTH&99%OCCUPYBANDWIDTH37 7.1APPLIEDPROCEDURES/LIMIT37 7.2TESTPROCEDURE37 7.3DEVIATIONFROMSTANDARD37 7.4TESTSETUP37 7.5EUTOPERATIONCONDITIONS37 7.6TESTRESULT38 8.PEAKOUTPUTPOWERTEST41 8.1APPLIEDPROCEDURES/LIMIT41 8.2TESTPROCEDURE41 8.3DEVIATIONFROMSTANDARD41 8.4TESTSETUP41 8.5EUTOPERATIONCONDITIONS41 8.6TESTRESULT42 9.CONDUCTEDBANDEDGEANDSPURIOUSEMISSION43 9.1APPLICABLESTANDARD43 9.2TESTPROCEDURE43 9.3DEVIATIONFROMSTANDARD43 9.4TESTSETUP43 9.5EUTOPERATIONCONDITIONS43 9.6TESTRESULTS43 10.ANTENNAREQUIREMENT50 11.TESTSETUPPHOTO51 12.EUTCONSTRUCTIONALDETAILS51 ProjectNo.:ZKT-2302133L0661E Page 5 of 51 1.VERSION ReportNo.VersionDescriptionApproved ZKT-230213L0661E-02Rev.01InitialissueofreportMar.6,2023 ProjectNo.:ZKT-2302133L0661E Page 6 of 51 2.SUMMARYOFTESTRESULTS Testproceduresaccordingtothetechnicalstandards: FCCPart15(15.247),SubpartC Standard Section TestItemResultRemark FCCpart15.203/15.247 (c) AntennarequirementPASS FCCpart15.207ACPowerLineConductedEmissionPASS FCCpart15.247(b)(3)ConductedPeakOutputPowerPASS FCCpart15.247(a)(2)ChannelBandwidth&99%OCBPASS FCCpart15.247(e)PowerSpectralDensityPASS FCCpart15.247(d)BandEdgePASS FCCpart15.205/15.209SpuriousEmissionPASS NOTE: (1)”N/A”denotestestisnotapplicableinthisTestReport ProjectNo.:ZKT-2302133L0661E Page 7 of 51 2.1TESTFACILITY ShenzhenZKTTechnologyCo.,Ltd. Add.:1/F,No.101,BuildingB,No.6,TangweiCommunityIndustrialAvenue,FuhaiStreet,Bao'an District,Shenzhen,China FCCTestFirmRegistrationNumber:692225 DesignationNumber:CN1299 ICRegisteredNo.:27033 CABidentifier:CN0110 2.2MEASUREMENTUNCERTAINTY Thereporteduncertaintyofmeasurementy±U , whereexpendeduncertaintyUisbasedonastandard uncertaintymultipliedbyacoveragefactorofk=2 , providingalevelofconfidenceofapproximately95 % 。 No.ItemUncertainty 1 3mcamberRadiatedspurious emission(9KHz-30MHz) U=4.5dB 2 3mcamberRadiatedspurious emission(30MHz-1GHz) U=4.8dB 3 3mchamberRadiatedspurious emission(1GHz-6GHz) U=4.9dB 4 3mchamberRadiatedspurious emission(6GHz-40GHz) U=5.0dB 5ConducteddisturbanceU=3.2dB 6RFBandEdgeU=1.68dB 7RFpowerconductedU=1.86dB 8RFconductedSpuriousEmissionU=2.2dB 9RFOccupiedBandwidthU=1.8dB 10RFPowerSpectralDensityU=1.75dB 11humidityuncertaintyU=5.3% 12Temperatureuncertainty U=0.59 °C ProjectNo.:ZKT-2302133L0661E…
Text truncated - open the document above for the full version.
ProjectNo.:ZKT-2302133L0661E Page 43 of 51 9.CONDUCTEDBANDEDGEANDSPURIOUSEMISSION TestRequirement:FCCPart15CSection15.247(d) TestMethod:KDB558074D0115.247MeasGuidancev05r02 9.1APPLICABLESTANDARD inany100kHzbandwidthoutsidethefrequencybandsinwhichthespreadspectrumintentionalradiatorin operating,theradiofrequencypowerthatisproducedbytheintentionalradiatorshallbeatleast20dBbelow thatinthe100kHzbandwidthwithinthebandthatcontainsthehighestlevelofthedesiredpower,Inaddition, radiatedemissionswhichfallintherestrictedbands,asdefinedin§15.205(a),mustalsocomplywiththe radiatedemissionlimitsspecifiedin15.209(a). 9.2TESTPROCEDURE Usingthefollowingspectrumanalyzersetting: A)SettheRBW=100KHz. B)SettheVBW=300KHz. C)Sweeptime=autocouple. D)Detectorfunction=peak. E)Tracemode=maxhold. F)Allowtracetofullystabilize. 9.3DEVIATIONFROMSTANDARD Nodeviation. 9.4TESTSETUP 9.5EUTOPERATIONCONDITIONS TheEUTtestedsystemwasconfiguredasthestatementsof2.4Unlessotherwiseaspecialoperating conditionisspecifiedinthefollowsduringthetesting. 9.6TESTRESULTS ProjectNo.:ZKT-2302133L0661E Page 44 of 51 Testplotasfollows: Testmode:802.11b LowestchannelHighestchannel Testmode:802.11g LowestchannelHighestchannel Testmode:802.11n(HT20) LowestchannelHighestchannel ProjectNo.:ZKT-2302133L0661E Page 45 of 51 Testmode:802.11n(HT40) LowestchannelHighestchannel ProjectNo.:ZKT-2302133L0661E Page 46 of 51 Testplotasfollows: ANT1-802.11b Lowestchannel Middlechannel Highestchannel ProjectNo.:ZKT-2302133L0661E Page 47 of 51 ANT1-802.11g Lowestchannel Middlechannel Highestchannel ProjectNo.:ZKT-2302133L0661E Page 48 of 51 ANT1-802.11n(HT20) Lowestchannel Middlechannel Highestchannel ProjectNo.:ZKT-2302133L0661E Page 49 of 51 ANT1-802.11n(HT40) Lowestchannel Middlechannel Highestchannel ProjectNo.:ZKT-2302133L0661E Page 50 of 51 10.ANTENNAREQUIREMENT Standardrequirement: FCCPart15CSection15.203/247(c) 15.203requirement: Anintentionalradiatorshallbedesignedtoensurethatnoantennaotherthanthatfurnishedbytheresponsiblepartyshall beusedwiththedevice.Theuseofapermanentlyattachedantennaorofanantennathatusesauniquecouplingtothe intentionalradiator,themanufacturermaydesigntheunitsothatabrokenantennacanbereplacedbytheuser,butthe useofastandardantennajackorelectricalconnectorisprohibited. 15.247(c)(1)(i)requirement: (i)Systemsoperatinginthe2400-2483.5MHzbandthatisusedexclusivelyforfixed.Point-to-pointoperationsmay employtransmittingantennaswithdirectionalgaingreaterthan6dBiprovidedthemaximumconductedoutputpowerof theintentionalradiatorisreducedby1dBforevery3dBthatthedirectionalgainoftheantennaexceeds6dBi. EUTAntenna: Theproducthas1antenna,TheantennaisInternalAntenna,thebestcasegainoftheantennais1.52dBi,reference totheappendixIIfordetails ProjectNo.:ZKT-2302133L0661E Page 51 of 51 11.TESTSETUPPHOTO ReferencetotheappendixIfordetails. 12.EUTCONSTRUCTIONALDETAILS ReferencetotheappendixIIfordetails. ※※※※※ENDOFREPORT※※※※※
ProjectNo.:ZKT-230213L0661E-01 Page 1 of 41 FCCTESTREPORT FCCID:2A96X-RS-01 ReportNumber.....................................:ZKT-2230213L0661E-01 DateofTest ....................................................... : Feb.12,2023toMar.6,2023 Dateofissue ......................................... : Mar.6,2023 Totalnumberofpages..........................41 TestResult..........................................: PASS TestingLaboratory...............................: ShenzhenZKTTechnologyCo.,Ltd. Address ............................................... : 1/F,No.101,BuildingB,No.6,TangweiCommunityIndustrial Avenue,FuhaiStreet,Bao'anDistrict,Shenzhen,China Applicant'sname................................:VioletUltraLtd Address ............................................... :128CityRoad,London,EC1V2NX,UK Manufacturer'sname ......................... :VioletUltraLtd Address ............................................... :128CityRoad,London,EC1V2NX,UK Testspecification: Standard................................................: FCCCFRTitle47Part15SubpartCSection15.247 ANSIC63.10:2013 Testprocedure.....................................: / Non-standardtestmethod ................ :N/A TestReportFormNo. ....................... : TRF-EL-111_V0 TestReportForm(s)Originator.....: ZKTTesting MasterTRF........................................: Dated:2020-01-06 ThisdevicedescribedabovehasbeentestedbyZKT,andthetestresultsshowthattheequipmentunder test(EUT)isincompliancewiththeFCCrequirements.Anditisapplicableonlytothetestedsample identifiedinthereport. Thisreportshallnotbereproducedexceptinfull,withoutthewrittenapprovalofZKT,thisdocumentmay bealteredorrevisedbyZKT,personalonly,andshallbenotedintherevisionofthedocument. Productname ..................................... : RithumSwitch Trademark...........................................: RITHUM, Model/Typereference.........................: RS-01-BL SerialmodelNo...................................:RS-YY-XX(anyversionRS-YY-XX,whereYYisanumberandXXis alphanumeric) Ratings..................................................: AC100-240V,50-60Hz,0.26AMaxor12-30VDC,1AMax ProjectNo.:ZKT-2230213L0661E-01 Page 2 of 41 Testingprocedureandtestinglocation: TestingLaboratory ....................................... :ShenzhenZKTTechnologyCo.,Ltd. Address ............................................................ :1/F,No.101,BuildingB,No.6,TangweiCommunity IndustrialAvenue,FuhaiStreet,Bao'anDistrict, Shenzhen,China AlenHe Testedby(name+signature).......................: JoeLiu Reviewer(name+signature).......................: LakeXie Approved(name+signature).......................: ProjectNo.:ZKT-2230213L0661E-01 Page 3 of 41 TableofContents Page 1.Version......................................................................................................................................................5 2.SUMMARYOFTESTRESULTS.............................................................................................................6 2.1TESTFACILITY...............................................................................................................................7 2.2MEASUREMENTUNCERTAINTY...................................................................................................7 3.GENERALINFORMATION......................................................................................................................8 3.1GENERALDESCRIPTIONOFEUT................................................................................................8 3.2DESCRIPTIONOFTESTMODES..................................................................................................9 3.3BLOCKDIGRAMSHOWINGTHECONFIGURATIONOFSYSTEMTESTED..............................9 3.4DESCRIPTIONOFSUPPORTUNITS(CONDUCTEDMODE).......................................................9 3.5EQUIPMENTSLISTFORALLTESTITEMS.................................................................................10 4.EMCEMISSIONTEST..........................................................................................................................12 4.1CONDUCTEDEMISSIONMEASUREMENT................................................................................12 4.1.1POWERLINECONDUCTEDEMISSIONLimits..................................................................12 4.1.2TESTPROCEDURE.............................................................................................................12 4.1.3DEVIATIONFROMTESTSTANDARD................................................................................12 4.1.4TESTSETUP........................................................................................................................13 4.1.5EUTOPERATINGCONDITIONS.........................................................................................13 4.1.6TESTRESULTS:...................................................................................................................14 4.2RADIATEDEMISSIONMEASUREMENT.....................................................................................16 4.2.1RadiatedEmissionLimits.....................................................................................................16 4.2.2TESTPROCEDURE.............................................................................................................17 4.2.3DEVIATIONFROMTESTSTANDARD................................................................................17 4.2.4TESTSETUP........................................................................................................................17 4.2.5EUTOPERATINGCONDITIONS.........................................................................................18 5.RADIATEDBandEMISSIONMEASUREMENT.....................................................................................23 5.1TestRequirement:......…
Text truncated - open the document above for the full version.
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 2 | 15C | 2.41 GHz - 2.46 GHz | 58.75 mW |