Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
74mm
(ShenzhenSenyangZhiyuanTechnologyCo.,Ltd) FederalCommunicationsCommission AuthorizationandEvaluationDivision 7435OaklandMillsRoad Columbia,MD21046 USA Date:September5,2024 FCCID:2A9CD-PRO5S Ref.#1:AttestationStatementsPart2.911(d)(5)(i)Filing (“ShenzhenSenyangZhiyuanTechnologyCo.,Ltd”)certifiesthattheequipmentforwhich authorizationissoughtisnot“covered”equipmentprohibitedfromreceivinganequipment authorizationpursuanttosection2.903oftheFCCrules. Ref.#2:AttestationStatementsPart2.911(d)(5)(ii)Filing (“ShenzhenSenyangZhiyuanTechnologyCo.,Ltd”)certifiesthat,asofthedateof thefilingoftheapplication,theapplicantisnotidentifiedontheCoveredListasan entityproducing“covered”equipment. Applicant:ShenzhenSenyangZhiyuanTechnologyCo.,Ltd Address:505,Floor5,WestBlock,Building405,SandaIndustrialZone,FutianDistrict, Shenzhen,518000China ContactPerson:Dandanhu Tel.:+8613410791236 Email:[email protected] Sincerely, Signature:
ShenzhenSenyangZhiyuanTechnologyCo.,Ltd Address:505,Floor5,WestBlock,Building405,SandaIndustrialZone,FutianDistrict, Shenzhen,518000China Date:2024-09-05 FederalCommunicationsCommission AuthorizationandEvaluationDivision 1435OaklandMillsRoad Columbia,MD21046 Ref:AttestationStatementsPart2.911(d)(7)Filing SUBJECT:FCCApplicationforFCCID:2A9CD-PRO5S FRN:0033079344 (“ShenzhenSenyangZhiyuanTechnologyCo.,Ltd”)certifiesthat,asofthedateofthefiling oftheapplication,SELLERHELPERINC.isourdesignatedU.S.agentforserviceofprocess fortheabovereferencedFCCID.(“ShenzhenSenyangZhiyuanTechnologyCo.,Ltd”) acceptstomaintainanagentfornolessthanoneyearafterthegranteehasterminatedall marketingandimportationortheconclusionofanyCommission-relatedproceedinginvolving theequipment. SELLERHELPERINC.accepts,asofthedateofthefilingoftheapplication,theobligationof thedesignatedU.S.agentforserviceofprocessfortheabovereferencedFCCID. DesignatedU.S.AgentInformation: Name:SELLERHELPERINC. Address:131217thStreet#1298,Denver,cO80202,UnitedStates FRN:0033406737 ContactPerson:FairyLee Tel.:(303)731-9873 Email:[email protected] Sincerely, Signedonbehalfof(ShenzhenSenyang ZhiyuanTechnologyCo.,Ltd) SignedonbehalfofSELLERHELPERINC. Name:DandanhuName:FairyLee Title:ManagerTitle:Manager Date:2024-09-05Date:2024-09-05
2.4GHz1608ChipAntenna: RANT1608F245C01/1608F245C04/1608F245C05 Application: WLAN,802.11b/g,Bluetooth,WLAN,etc... Features SMD,highreliability,ultraImpact,Omni-directional... PartnumberInformation RANT1608F245C01/04 (A)(B)(C)(D)(E)(F) ElectricalSpecification DimensionandTerminalConfiguration No.TerminalName 1Feeding/GNG 2GND/Feeding (A)ProductTypeChipAntenna (B)SizeCode 1.6x0.8mm( ± 0.1mm) (C)MaterialHighKmaterial (D)Frequency2.4~2.5GHz (E)FeedingmodePIFA&SingleFeeding (F)AntennatypeType=01/04/05 WorkingFrequencyRange2400~2500MHz Bandwidth120MHz(Min.) PeakGain2.7dBi(Typ.) Impedance50Ohm Returnloss10dB(Min) PolarizationLinear AzimuthBeamwidthOmni-directional OperationTemperature( °C )-40~85 °C ResistancetoSolderingHeats 10sec.(@280 °C ) TerminationNi/Au(Leadless) Dimension(mm) L 1.60±0.10 W 0.80 ± 0.10 T 0.80 ± 0.10 RAINInternationalTechnol o gyCo.,Ltd.TEL:13530576606 2.4GHz1608ChipAntenna: RANT1608F245C01/1608F245C04/1608F245C05 2 1 EvaluationBoardReference Toplayer: Bottomlayer: Suggestions for Layout of strip boards are as follows: 2.4GHz1608ChipAntenna: RANT1608F245C01/1608F245C04/1608F245C05 3 Toplayer: Toplayer: Layout suggestions for abnormals are as follows: 2.4GHz1608ChipAntenna: RANT1608F245C01/1608F245C04/1608F245C05 4 ElectricalCharacteristics ReturnLoss&Radiation ELECTRICALCHARACTERISTICSS11 RadiationPattern 2.4GHz1608ChipAntenna: RANT1608F245C01/1608F245C04/1608F245C05 5 ElectricalCharacteristics 2.4GHz1608ChipAntenna: RANT1608F245C01/1608F245C04/1608F245C05 6 TapingSpecifications ReelandTapingSpecification ReelSpecification TYPESIZEABCD 16087”4K/Reel 4.0±0.5 4.0±213.5±0.5178±2 TappingSpecification PackagingTypeABWEFGHTψDP PaperType1608 1.90±0.203.50±0.208.0±0.201.75±0.103.5±0.054.0±0.102.0±0.050.75±0.10 1.50±0.10 4.0±0.1 2.4GHz1608ChipAntenna: RANT1608F245C01/1608F245C04/1608F245C05 7 ReliabilityTable TestItemProcedure Requirements CeramicType Remark (Reference) Electrical Characterization Fulfilltheelectrical specification UserSpec. Thermal Shock 1.Preconditioning: 50±10°C/1hr,thenkeepfor24±1hrsatroomtemp. 2.Initialmeasure:Spec:referInitialspec. 3.Rapidchangeoftemperaturetest: -30°Cto+85°C;100cycles; 15minutesatLowercategorytemperature; 15minutesatUppercategorytemperature. NoVisibleDamage. Fulfilltheelectrical specification. MIL-STD-202 107 Temperature Cycling 1.Initialmeasure:Spec:referInitialspec. 2.100Cycles(-30°Cto+85°C),SoakMode=1(2Cycle/hours). 3.Measurementat24±2Hoursaftertestcondition. NoVisibleDamage. Fulfilltheelectrical specification. JESD22 JA104 HighTemperature Exposure 1.Initialmeasure:Spec:referInitialspec. 2.Unpowered;500hours@T=+85°C. 3.Measurementat24±2hoursaftertest. NoVisibleDamage. Fulfilltheelectrical specification. MIL-STD-202 108 LowTemperature Storage 1.Initialmeasure:Spec:referInitialspec. 2.Unpowered:500hours@T=-30°C. 3.Measurementat24±2hoursaftertest. NoVisibleDamage. Fulfilltheelectrical specification. MIL-STD-202 108 Solderability (SMDBottomSide) Dippingmethod: a.Temperature:235±5°C b.Dippingtime:3±0.5s Thesoldershouldcover over95%ofthecritical areaofbottomside. IEC60384-21/22 4.10 SolderingHeat Resistance (RSH) Preheatingtemperature:150±10°C. Preheatingtime:1~2min. Soldertemperature:260±5°C. Dippingtime:5±0.5s NoVisibleDamage.IEC60384-21/22 4.10 Vibration5g'sfor20min.,12cycleseachof3orientations Note:Use8"X5"PCB.031"thick7securepointson,onelong sideand2securepointsatcornersofoppositesides.Parts mountedwithin2"fromanysecurepoint.Testfrom10-2000 Hz. NoVisibleDamage.MIL-STD-202 Method204 Mechanical Shock Threeshocksineachdirectionshallbeappliedalongthethree mutuallyperpendicularaxesofthetestspecimen(18shocks) Peakvalue:1,500g’s Duration:0.5ms Velocitychange:15.4ft/s Waveform:Half-sine NoVisibleDamage.MIL-STD-202 Method213 Humidity Bias 1.Humidity:85%R.H.,Temperature:85±2°C. 2.Time:500±24hours. 3.Measurementat24±2hrsaftertestcondition. NoVisibleDamage. Fulfilltheelectrical specification. MIL-STD-202 Method106 2.4GHz3216ChipAntenna: RANT1608F245C01/RANT1608F245C04/1608F245C05 _ 8 Board Flex (SMD) 1.Mountingmethod: IR-Reflow.PCBSize(L:100×W:40×T:1.6mm) 2.Applytheloadindirectionofthearrowuntilbendingreaches 2mm. NoVisibleDamage.AEC-Q200 005 AdhesionForceof1.8Kgfor60seconds.NoVisibleDamage Magnificationof20Xor greatermaybeemployed forinspectionofthe mechanicalintegrityofthe devicebodyterminalsand body/terminaljunction. AEC-Q200 006 Physical Dimension Anyapplicablemethodusingx10magnification,micrometers, calipers,gauges,contourprojectors,orothermeasuring equipment,capableofdeterminingtheactualspecimen dimensions. Inaccordancewith specification. JESD22 JB100 RevisionHistory RevisionDateContent 12019/03/01NewDatasheet 22020/02/22Add2Dradiationcharacteristic
ShenzhenSenyangZhiyuanTechnologyCo.,Ltd Date:2024-07-09 ProductModelNumber:PRO5S,J33,J44,J55,J66,J77,J88,J99,Pro5S, Pro9,Pro11,Pro13,J29,J30,J38,J15,J2,J25,RS90,RS85RS16,RS25, RS39,RS29,R5,J32,TWS,PRO13,J18,J17,RS39,J25,PRO9S,PRO6S, PRO6,PRO7S,PRO7,S190,J20,AP09,S6,PRO,H01,H02,H03,H05,H06, H07,H08,H09,H10 Towhomitmayconcern, Re:ProductCertificationRepresentativeAuthorizationLetter WeauthorizeQAILaboratoriesLtd.3980NorthFraserWay,BurnabyB.C. CanadaV5J5K5toactonourbehalfonallmattersconcerningtheabove namedequipment. Thisshallincludethefollowing: Testing Approvalapplicationsandprocedures WedeclarethatORGANIZATION.isallowedtoforwardallinformation relatedtotheapprovalprojecttotheappliedcertificationbodyandtothe notificationentitiesandtodiscussanyissuesconcerningtheapproval application.AnyandallactscarriedoutbyORGANIZATION.onourbehalf shallhavethesameeffectasactsofourown. By: ContactListedonFCCWesbite Title:Manager Email:[email protected] Telephone:+8613410791236 Onbehalfof:ShenzhenSenyangZhiyuanTechnologyCo.,Ltd
ShenzhenSenyangZhiyuanTechnologyCo.,Ltd OfficeofEngineeringTechnology FederalCommunicationsCommission 7435OaklandMillsRoad Columbia,MD21046 USA Date:September5,2024 Subject;RequestforConfidentiality FCCID:2A9CD-PRO5S ToWhomItMayConcern, PursuanttotheprovisionsoftheCommission’srulesTitle47Sections§0.457and§0.459,we arerequestingtheCommissiontowithholdthefollowingattachment(s)asconfidential documentsfrompublicdisclosureindefinitely. Thesedocumentscontaindetailedsystemandequipmentdescriptionsandareconsideredas proprietaryinformationinoperationoftheequipment.Thepublicdisclosureofthese documentsmightbeharmfultoourcompanyandwouldgivecompetitorsanunfairadvantage inthemarket. SchematicDiagram BlockDiagram PartsList OperationalDescription Tune-upProcedure SoftwareSecurityRequirementsforUNIIdevices Inadditionaltoabovementioneddocuments,inordertocomplywiththemarketingregulations inTitle47CFR§2.803andtheimportationrulesinTitle47CFR§2.1204,whileensuringthat businesssensitiveinformationremainsconfidentialuntiltheactualmarketingofnewly authorizeddevices,werequestShortTermConfidentialityofthefollowingattachment(s); ExternalPhotos TestSetupPhotos InternalPhotos UserManual For45days,pursuanttoPublicNoticeDA04-1705. OR For180dayspursuanttoKDB726920D01. Itisourunderstandingthatallmeasurementtestreports,FCCIDlabelformatand correspondenceduringthecertificationreviewprocesscannotbegrantedasconfidential documentsandthisinformationwillbeavailableforpublicreviewoncethegrantofequipment authorizationisissued. Sincerely, Signature: Name:Dandanhu Title:Manager
FCCID:2A9CD-PRO5S EUTPHOTOS(ExternalPhotos) FCCID:2A9CD-PRO5S FCCID:2A9CD-PRO5S FCCID:2A9CD-PRO5S ※※※※※ENDOFREPORT※※※※※
FCCID:2A9CD-PRO5S EUTPHOTOS(InternalPhotos) FCCID:2A9CD-PRO5S ANT FCCID:2A9CD-PRO5S FCCID:2A9CD-PRO5S ※※※※※ENDOFREPORT※※※※※
FCCID:2A9CD-PRO5S RFExposureEvaluation AccordingtoKDB447498D01GeneralRFExposureGuidancev06andpart2.1093 , UnlessspecificallyrequiredbythepublishedRFexposureKDBprocedures,standalone 1-gheadorbodyand10-gextremitySARevaluationforgeneralpopulationexposure conditions,bymeasurementornumericalsimulation,isnotrequiredwhenthe correspondingSARTestExclusionThresholdcondition(s),listedbelow,is(are)satisfied. For100MHzto6GHzandtestseparationdistances≤50mm,the1-gand10-gSARtest exclusionthresholdsaredeterminedbythefollowing: [(max.powerofchannel,includingtune-uptolerance,mW)/(min.testseparationdistance, mm)]·[√f (GHz) ]≤3.0for1-gSAR,and≤7.5for10-gextremitySAR,where f (GHz) istheRFchanneltransmitfrequencyinGHz PoweranddistanceareroundedtothenearestmWandmmbeforecalculation Theresultisroundedtoonedecimalplaceforcomparison Here, ForBluetooth Mode Max Power (dBm) Tune-up power (dBm) Max Power (mW) Frequency(MHz) Min. Distance (mm) Calc. thresholds limit BR/EDR33 ± 12.51244150.7843.0 SoaSARtestisnotrequired
Project No.: ZKT-240820L10197E Page 1 of 97 FCC TEST REPORT FCC ID:2A9CD-PRO5S Report Number. .............................. : ZKT-240820L10197E Date of Test ...................................... : Aug. 08, 2024 – Aug. 16, 2024 Date of issue .................................... : Aug. 16, 2024 Test Result ..................................... : PASS Testing Laboratory. ........................ : Shenzhen ZKT Technology Co., Ltd. Address .......................................... : 1/F, No. 101, Building B, No. 6, Tangwei Community Industrial Avenue, Fuhai Street, Bao'an District, Shenzhen, China Applicant's name ......................... : Shenzhen Senyang Zhiyuan Technology Co.,Ltd Address .......................................... : 505,Floor 5,West Block,Building 405, Sanda Industrial Zone,Futian District, Shenzhen,518000 China Manufacturer's name ................... : Shenzhen Senyang Zhiyuan Technology Co.,Ltd Address .......................................... : 505,Floor 5,West Block,Building 405, Sanda Industrial Zone,Futian District, Shenzhen,518000 China Test specification: Standard ........................................... : FCC CFR Title 47 Part 15 Subpart C Section 15.247 Test procedure ................................. : KDB558074 D01 15.247 Meas Guidance v05r02 ANSI C63.10:2013 Non-standard test method ............. : N/A Test Report Form No. ...................... : TRF-EL-112_V0 Test Report Form(s) Originator ........ : ZKT Testing Master TRF .................................... : Dated: 2021-04-22 This device described above has been tested by ZKT, and the test results show that the equipment under test (EUT) is in compliance with the FCC requirements. And it is applicable only to the tested sample identified in the report. This report shall not be reproduced except in full, without the written approval of ZKT, this document may be altered or revised by ZKT, personal only, and shall be noted in the revision of the document. Product name ................................. : Wireless Headset Trademark ...................................... : / Model/Type reference ...................... : PRO5S, J33, J44, J55, J66, J77, J88, J99, Pro5S, Pro9, Pro11, Pro13, J29, J30, J38, J15, J2, J25, RS90, RS85RS16, RS25, RS39, RS29, R5, J32, TWS, PRO13, J18, J17, RS39, J25, PRO9S, PRO6S, PRO6, PRO7S, PRO7, S190, J20, AP09, S6, PRO, H01, H02, H03, H05, H06, H07, H08, H09, H10 Model difference .............................. : PRO5S is tested model, other models are derivative models .The models are identical in circuit, only different on the model names. So the test data of PRO5S can represent the remaining models. Ratings ............................................. : Input: DC 5V or DC 3.7V power by battery Project No.: ZKT-240820L10197E Page 2 of 97 Testing procedure and testing location: Testing Laboratory ..................................... : Shenzhen ZKT Technology Co., Ltd. Address ...................................................... : 1/F, No. 101, Building B, No. 6, Tangwei Community Industrial Avenue, Fuhai Street, Bao'an District, Shenzhen, China Jim Liu Tested by (name + signature) .................... : Tom Zou Reviewer (name + signature) ..................... : Lake Xie Approved (name + signature) .................... : Project No.: ZKT-240820L10197E Page 3 of 97 Table of Contents Page 1. VERSION ........................................................................................................................................... 5 2. TEST SUMMARY .............................................................................................................................. 6 2.1 TEST FACILITY ............................................................................................................................... 7 2.2 MEASUREMENT UNCERTAINTY ................................................................................................... 7 3. GENERAL INFORMATION ............................................................................................................... 8 3.1 GENERAL DESCRIPTION OF EUT ................................................................................................ 8 3.2 Test Setup Configuration ................................................................................................................. 9 3.3 Support Equipment ........................................................................................................................ 10 3.4 Test Mode ...................................................................................................................................... 10 3.5 EQUIPMENTS LIST FOR ALL TEST ITEMS ................................................................................ 11 4. EMC EMISSION TEST .................................................................................................................... 13 4.1 Conducted emissions .................................................................................................................... 13 4.1.1 POWER LINE CONDUCTED EMISSION Limits ........................................................................ 13 4.1.2 TEST PROCEDURE ................................................................................................................... 13 4.1.3 DEVIATION FROM TEST STANDARD ...................................................................................... 13 4.1.4 TEST SETUP .............................................................................................................................. 14 4.1.5 EUT OPERATING CONDITIONS ............................................................................................... 14 4.1.6 Test Result .................................................................................................................................. 14 4.2 Radiated emissions.........................................................................................................…
Text truncated - open the document above for the full version.
FCCID:2A9CD-PRO5S EUTTESTPHOTOS
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 2.40 GHz - 2.48 GHz | 2.00 mW |

Wireless Headset
Equipment Class
DSS - Part 15 Spread Spectrum Transmitter
Wireless Headset
Equipment Class
DSS - Part 15 Spread Spectrum Transmitter
Wireless Headset
Equipment Class
DSS - Part 15 Spread Spectrum Transmitter
Bluetooth Headset
Equipment Class
DSS - Part 15 Spread Spectrum Transmitter
Wireless headset
Equipment Class
DSS - Part 15 Spread Spectrum Transmitter