Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
FCC Caution. § 15.19 Labelling requirements. This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. § 15.21 Information to user. Any Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. § 15.105 Information to the user. Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: -Reorient or relocate the receiving antenna. -Increase the separation between the equipment and receiver. -Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. -Consult the dealer or an experienced radio/TV technician for help.
GuangzhouVeteranIntelligentTechnologyCo.Ltd. 04/25/2023 EurofinsElectricalandElectronicTestingNA,Inc. 914WestPatapscoAvenue Baltimore,MD21230 RE:AttestationStatementsPart2.911(d)(5)(i)requestfor(FCCID:2A9E6-PATTON) [GuangzhouVeteranIntelligentTechnologyCo.Ltd.](âtheapplicantâ)certifiesthatthe equipmentforwhichauthorizationissoughtisnotâcoveredâequipmentprohibited fromreceivinganequipmentauthorizationpursuanttosection2.903oftheFCCrules. Sincerely, (Applicantsignature) (Applicantprintedname)LinneaLin GuangzhouVeteranIntelligentTechnologyCo.Ltd. 04/25/2023 EurofinsElectricalandElectronicTestingNA,Inc. 914WestPatapscoAvenue Baltimore,MD21230 RE:AttestationStatementsPart2.911(d)(5)(ii)requestfor(FCCID:2A9E6-PATTON) [GuangzhouVeteranIntelligentTechnologyCo.Ltd.](âtheapplicantâ)certifiesthat,as ofthedateofthefilingoftheapplication,theapplicantisnotidentifiedontheCovered Listasanentityproducingâcoveredâequipment. Sincerely, (Applicantsignature) (Applicantprintedname) LinneaLin
AttestationStatements 04/03/2023 TO:FederalCommunicationsCommission AuthorizationandEvaluationDivision 7435OaklandMillsRoad Columbia,MD21046,USA RE:AttestationStatementsPart2.911(d)(7)requestfor(FCCID:2A9E6-PATTON) GuangzhouVeteranIntelligentTechnologyCo.Ltd.theundersigned,herebyauthorize (GSSSERVICEINC)toactasourdesignatedU.S.agentforserviceofprocess, ( GuangzhouVeteranIntelligentTechnologyCo.Ltd. )acceptstomaintainanagentfor nolessthanoneyearafterthegranteehasterminatedallmarketingandimportationor theconclusionofanyCommission-relatedproceedinginvolvingtheequipment. (GSSSERVICEINC)acceptstheresponsibilitytoactasdesignatedU.S.agentfor serviceofprocess. ApplicantInformationďź Companyname: GuangzhouVeteranIntelligentTechnologyCo.Ltd. ContactName: LinneaLin Address: Part2ofNo.45,NorthenIndustrialroad,Xinlouvillage,Baiyundistrict, Guangzhou,Guangdong,China. TelephoneNo:13138036757 Email:[email protected] Signature U.S.AgentInformation: CompanyName: GSSSERVICEINC Address: 6547NAcademyBlvd#2266ColoradoSpringsCo80918USA FRN: 0033402082 ContactName:MichouxLogan TelephoneNo:001-949-2990192 Email:[email protected] Signature
GuangzhouVeteranIntelligentTechnologyCo.Ltd. 4/26/2023 EurofinsElectricalandElectronicTestingNA,Inc. 914WestPatapscoAvenue Baltimore,MD21230 RE:CONFIDENTIALITYREQUESTFOR(Electricunicycle/ #ANDFCCID:2A9E6-PATTON ToWhomItMayConcern: Thisletterservesasanofficialrequestforconfidentialityundersections0.457and0.459 ofCFR47.Wehaverequestedthatthe -BlockDiagram -Schematics -OperationalDescription requiredtobesubmittedwiththisapplicationbepermanentlywithheldfrompublic review. Theabovedocumentsarecompanyproprietaryinformationthatcouldnevergetintothe possessionofyourcompetition. Pleasecontactmeifthereisanyinformationyoumayneed. Sincerely, Clientâssignature: Clientâsname/title:LinneaLin/PM Contactinformation/address:Part2ofNo.45,NorthenIndustrialroad,Xinlouvillage,Baiyun district,Guangzhou,Guangdong,China.
GuangzhouVeteranIntelligentTechnologyCo.Ltd. 4/26/2023 EurofinsElectricalandElectronicTestingNA,Inc. 914WestPatapscoAvenue Baltimore,MD21230 RE:LETTEROFAGENTAUTHORIZATION ToWhomItMayConcern: We,theundersigned,herebyauthorize(ShenzhenCTATestingTechnologyCo.,Ltd.)toacton ourbehalfinallmattersrelatingtoapplicationforequipmentauthorization,includingthesigning ofalldocumentsrelatingtothesematters. Wealsoherebycertifythatnopartytotheapplicationauthorizedhereunderissubjecttothe denialofbenefits,includingFCCbenefits,pursuanttoSection5301oftheAnti-DrugAbuseAct of1988,21U.S.C.853(a). Thisagreementexpiresoneyearfromthecurrentdate. Sincerely, Clientâssignature: Clientâsname/title:LinneaLin/PM Contactinformation/address:Part2ofNo.45,NorthenIndustrialroad,Xinlouvillage,Baiyun district,Guangzhou,Guangdong,China.
FCCID:2A9E6-PATTON ExternalPhotosoftheEUT Photo1 Photo2 Photo3 FCCID:2A9E6-PATTON Photo4 Photo5 Photo6 FCCID:2A9E6-PATTON Photo7
2.9cm*3.3cm
FCCID:2A9E6-PATTON InternalPhotosoftheEUT Photo1 Photo2 Photo3 FCCID:2A9E6-PATTON Photo4 Photo5 Photo6 FCCID:2A9E6-PATTON Photo7 Photo8 Photo9 FCCID:2A9E6-PATTON Photo10 Photo11 Photo12 BLEPCB Antenna FCCID:2A9E6-PATTON Photo13 Photo14 Photo15 FCCID:2A9E6-PATTON Photo16 Photo17 Photo18 FCCID:2A9E6-PATTON Photo19
RFExposureevaluation FCCID:2A9E6-PATTON 1.1.ApplicableStandard Accordingto§1.1307(b)(1),systemsoperatingundertheprovisionsofthissectionshallbeoperatedina mannerthatensuresthatthepublicisnotexposedtoradiofrequencyenergylevelinexcessofthe Commissionâsguidelines. Accordingto§1.1310and§2.1093RFexposurerequirement KDB447498v06:MobileandPortableDevicesRFExposureProceduresandEquipmentAuthorization Policies 1.2.Requirement AccordingtoKDB447498D01GeneralRFExposureGuidancev06Section4.3.1StandaloneSARtest exclusionconsiderations:âUnlessspecificallyrequiredbythepublishedRFexposureKDBprocedures, standalone1-gheadorbodyand10-gextremitySARevaluationforgeneralpopulationexposureconditions, bymeasurementornumericalsimulation,isnotrequiredwhenthecorrespondingSARTestExclusion Thresholdcondition,listedbelow,issatisfied.Thesetestexclusionconditionsarebasedonsource-based time-averagedmaximumconductedoutputpoweroftheRFchannelrequiringevaluation,adjustedfortune-up tolerance,andtheminimumtestseparationdistancerequiredfortheexposureconditions.22Theminimum testseparationdistanceisdeterminedbythesmallestdistancefromtheantennaandradiatingstructuresor outersurfaceofthedevice,accordingtothehostformfactor,exposureconditionsandplatformrequirements, toanypartofthebodyorextremityofauserorbystander(see5)ofsection4.1).ToqualifyforSARtest exclusion,thetestseparationdistancesappliedmustbefullyexplainedandjustifiedbytheoperating configurationsandexposureconditionsofthetransmitterandapplicablehostplatformrequirements,typically intheSARmeasurementorSARanalysisreport,accordingtotherequiredpublishedRFexposureKDB procedures.WhennootherRFexposuretestingorreportingisrequired,astatementofjustificationand compliancemustbeincludedintheequipmentapproval,inlieuoftheSARreport,toqualifyfortheSARtest exclusion.Whenrequired,thedevicespecificconditionsdescribedintheotherpublishedRFexposureKDB proceduresmustbesatisfiedbeforeapplyingtheseSARtestexclusionprovisions;forexample,handheldPTT two-wayradios,handsets,laptops&tabletsetc.23â [(max.powerofchannel,includingtune-uptolerance,mW)/(min.testseparationdistance,mm)] ¡ [âf(GHz)] â¤3.0for1-gSARandâ¤7.5for10-gextremitySAR,where: â˘f(GHz)istheRFchanneltransmitfrequencyinGHz ⢠PoweranddistanceareroundedtothenearestmWandmmbeforecalculation â˘Theresultisroundedtoonedecimalplaceforcomparison â˘3.0and7.5arereferredtoasthenumericthresholdsinthestep2below Thetestexclusionsareapplicableonlywhentheminimumtestseparationdistanceis ⤠50mmandfor transmissionfrequenciesbetween100MHzand6GHz.Whentheminimumtestseparationdistanceis < 5 mm,adistanceof5mmaccordingto5)insection4.1isappliedtodetermineSARtestexclusion. 1.3.Manufacturingtolerance GFSK(Peak) ChannelChannel0Channel19Channel39 Target(dBm)4.04.04.0 ToleranceÂą(dB)1.01.01.0 Page2of2 2.EvaluationResult EvaluationResults Band/Modef(GHz) Antenna Distance (mm) RFoutputpower (includingtune-up tolerance) SARTest Exclusion Threshold SARTest Exclusion dBmmW BT2.45055.03.160.98<3.0Yes 3.Conclusion ThemeasurementresultscomplywiththeFCCLimitper47CFR2.1093fortheuncontrolledRFExposure andSARExclusionThresholdperKDB447498v06 .....................EndofReport.........................
1.AntennaDescription: AntennatypePCBantenna ModelSherman-S Frequencyrange2402-2480MHz ManufacturerGuangzhouVeteranIntelligentTechnologyCo.Ltd. ANTPeakGain1.92dBi 2.AntennaPhoto: Length:11.82mm Width:5.02mm 3.TestEquipment&Conditions 3.1Testinstrument VSWRistestedusingAgilentE5071Bconnectedto ahandmechanism,andthestatusisfreespace. 3.2Testenvironmentandmethods 4ďźAntennaRadiationPattern 2402MHz 2440MHz 2480MHz
ShenzhenCTATestingTechnologyCo.,Ltd. Room106,Building1,YibaolaiIndustrialPark,QiaotouCommunity,FuhaiStreet, BaoâanDistrict,Shenzhen,China ShenzhenCTATestingTechnologyCo.,Ltd. Room106,Building1,YibaolaiIndustrialPark,QiaotouCommunity,FuhaiStreet,BaoâanDistrict,Shenzhen,China Tel:+86-75523225875E-mail:[email protected]:http://www.cta-test.cn FCCPART15SUBPARTCTESTREPORT FCCPART15.247 ReportReferenceNo........................: FCCID.................................................: CTA23041100301 2A9E6-PATTON Compiledby (position+printedname+signature) .. : FileadministratorsZoeyCao Supervisedby (position+printedname+signature) .. : ProjectEngineerAmyWen Approvedby (position+printedname+signature) .. : RFManagerEricWang Dateofissue.........................................:Apr.17,2023 TestingLaboratoryName................: ShenzhenCTATestingTechnologyCo.,Ltd. Address.................................................: Room106,Building1,YibaolaiIndustrialPark,QiaotouCommunity, FuhaiStreet,BaoâanDistrict,Shenzhen,China Applicantâsname ............................... : GuangzhouVeteranIntelligentTechnologyCo.Ltd. Address.................................................: Part2ofNo.45,NorthenIndustrialroad,Xinlouvillage,Baiyun district,Guangzhou,Guangdong,China. Testspecification .............................. : Standard ................................................ : FCCPart15.247 ShenzhenCTATestingTechnologyCo.,Ltd.Allrightsreserved. Thispublicationmaybereproducedinwholeorinpartfornon-commercialpurposesaslongasthe ShenzhenCTATestingTechnologyCo.,Ltd.isacknowledgedascopyrightownerandsourceofthe material.ShenzhenCTATestingTechnologyCo.,Ltd.takesnoresponsibilityforandwillnotassume liabilityfordamagesresultingfromthereader'sinterpretationofthereproducedmaterialduetoits placementandcontext. Equipmentdescription.....................: Electricunicycle TradeMark ............................................ : Leaperkim Manufacturer ......................................... : GuangzhouVeteranIntelligentTechnologyCo.Ltd. Model/Typereference.........................: Patton ListedModels......................................: N/A Modulation...........................................:GFSK Frequency..............................................From2402MHzto2480MHz Ratings ................................................... : DC108VFromBatteryandDC126VFromexternalcircuit Result.....................................................:PASS ReportNo.:CTA23041100301Page 2 of 39 ShenzhenCTATestingTechnologyCo.,Ltd. Room106,Building1,YibaolaiIndustrialPark,QiaotouCommunity,FuhaiStreet,BaoâanDistrict,Shenzhen,China Tel:+86-75523225875E-mail:[email protected]:http://www.cta-test.cn TESTREPORT EquipmentunderTest:Electricunicycle Model/Type:Patton ListedModels:N/A Applicant : GuangzhouVeteranIntelligentTechnologyCo.Ltd. Address: Part2ofNo.45,NorthenIndustrialroad,Xinlouvillage,Baiyundistrict, Guangzhou,Guangdong,China. Manufacturer : GuangzhouVeteranIntelligentTechnologyCo.Ltd. Address: Part2ofNo.45,NorthenIndustrialroad,Xinlouvillage,Baiyundistrict, Guangzhou,Guangdong,China. TestResult : PASS Thetestreportmerelycorrespondstothetestsample. Itisnotpermittedtocopyextractsofthesetestresultwithoutthewrittenpermissionofthetest laboratory. ReportNo.:CTA23041100301Page 3 of 39 ShenzhenCTATestingTechnologyCo.,Ltd. Room106,Building1,YibaolaiIndustrialPark,QiaotouCommunity,FuhaiStreet,BaoâanDistrict,Shenzhen,China Tel:+86-75523225875E-mail:[email protected]:http://www.cta-test.cn Contents 1TESTSTANDARDS...................................................................................................................4 2SUMMARY......................................................................................................................................5 2.1GeneralRemarks5 2.2ProductDescription5 2.3EquipmentUnderTest5 2.4ShortdescriptionoftheEquipmentunderTest(EUT)5 2.5EUToperationmode6 2.6BlockDiagramofTestSetup6 2.7RelatedSubmittal(s)/Grant(s)6 2.8Modifications6 3TESTENVIRONMENT.............................................................................................................7 3.1Addressofthetestlaboratory7 3.2TestFacility7 3.3Environmentalconditions7 3.4Summaryofmeasurementresults8 3.5Statementofthemeasurementuncertainty8 3.6EquipmentsUsedduringtheTest9 4TESTCONDITIONSANDRESULTS............................................................................10 4.1ACPowerConductedEmission10 4.2RadiatedEmissionsandBandEdge13 4.3MaximumPeakOutputPower20 4.4PowerSpectralDensity21 4.56dBBandwidth23 4.6Out-of-bandEmissions25 4.7AntennaRequirement29 5TESTSETUPPHOTOSOFTHEEUT..........................................................................30 6PHOTOSOFTHEEUT.........................................................................................................31 ReportNo.:CTA23041100301Page 4 of 39 ShenzhenCTATestingTechnologyCo.,Ltd. Room106,Building1,YibaolaiIndustrialPark,QiaotouCommunity,FuhaiStreet,BaoâanDistrict,Shenzhen,China Tel:+86-75523225875E-mail:[email protected]:http://www.cta-test.cn 1TESTSTANDARDS Thetestswereperformedaccordingtofollowingstandards: FCCRulesPart15.247:FrequencyHopping,DirectSpreadSpectrumandHybridSystemsthatarein operationwithinthebandsof902-928MHz,2400-2483.5MHz,and5725-5850MHz. ANSIC63.10-2013:AmericanNationalStandardforTestingUnlicensedWirelessDevices KDB558074D01V05r02:GuidanceforPerformingComplianceMeasurementsonDigitalTransmission Systems(DTS)OperatingUnder§15.247 ReportNo.:CTA23041100301Page 5 of 39 ShenzhenCTATestingTechnologyCo.,Ltd. Room106,Building1,YibaolaiIndustrialPark,QiaotouCommunity,FuhaiStreet,BaoâanDistrict,Shenzhen,China Tel:+86-75523225875E-mail:[email protected]:http://www.cta-test.cn 2SUMMARY 2.1GeneralRemarks Dateofreceiptoftestsample:Apr.11,2023 Testingcommencedon:Apr.11,2023 Testingconcludedon: Apr.17,2023 2.2ProductDescription ProductDescription:Electricunicycle Model/Typereference:Patton Powersupply:DC108VFromBatteryandDC126VFromexternalcircuit AdapterinfoâŚ
Text truncated - open the document above for the full version.
ReportNo.:CTA23041100301Page 21 of 39 ShenzhenCTATestingTechnologyCo.,Ltd. Room106,Building1,YibaolaiIndustrialPark,QiaotouCommunity,FuhaiStreet,BaoâanDistrict,Shenzhen,China Tel:+86-75523225875E-mail:[email protected]:http://www.cta-test.cn 4.4PowerSpectralDensity Limit Fordigitallymodulatedsystems,thepowerspectraldensityconductedfromtheintentionalradiatortothe antennashallnotbegreaterthan8dBminany3kHzbandduringanytimeintervalofcontinuous transmission. TestProcedure 1.Usethisprocedurewhenthemaximumpeakconductedoutputpowerinthefundamentalemissionisused todemonstratecompliance. 2.SettheRBWâĽ3kHz. 3.SettheVBWâĽ3ĂRBW. 4.Setthespanto1.5timestheDTSchannelbandwidth. 5.Detector=peak. 6.Sweeptime=autocouple. 7.Tracemode=maxhold. 8.Allowtracetofullystabilize. 9.Usethepeakmarkerfunctiontodeterminethemaximumpowerlevel. 10.Ifmeasuredvalueexceedslimit,reduceRBW(nolessthan3kHz)andrepeat. 11.TheresultingpeakPSDlevelmustbe8dBm. TestConfiguration EUTSPECTRUM ANALYZER TestResults TypeChannel PowerSpectralDensity (dBm/3KHz) Limit(dBm/3KHz)Result GFSK1Mbps 00-15.59 8.00Pass 19-14.99 39-14.80 Testplotasfollows: ReportNo.:CTA23041100301Page 22 of 39 ShenzhenCTATestingTechnologyCo.,Ltd. Room106,Building1,YibaolaiIndustrialPark,QiaotouCommunity,FuhaiStreet,BaoâanDistrict,Shenzhen,China Tel:+86-75523225875E-mail:[email protected]:http://www.cta-test.cn BLEGFSK1Mpbs CH00 CH19 CH39 ReportNo.:CTA23041100301Page 23 of 39 ShenzhenCTATestingTechnologyCo.,Ltd. Room106,Building1,YibaolaiIndustrialPark,QiaotouCommunity,FuhaiStreet,BaoâanDistrict,Shenzhen,China Tel:+86-75523225875E-mail:[email protected]:http://www.cta-test.cn 4.56dBBandwidth Limit Fordigitalmodulationsystems,theminimum6dBbandwidthshallbeatleast500kHz TestProcedure Thetransmitteroutputwasconnectedtothespectrumanalyzerthroughanattenuator.Thebandwidthofthe fundamentalfrequencywasmeasuredbyspectrumanalyzerwith100KHzRBWand300KHzVBW.The6dB bandwidthisdefinedasthetotalspectrumthepowerofwhichishigherthanpeakpowerminus6dB. TestConfiguration EUTSPECTRUM ANALYZER TestResults TypeChannel 6dBBandwidth (MHz) Limit(KHz)Result GFSK1Mbps 000.704 âĽ500Pass190.644 390.688 Testplotasfollows: ReportNo.:CTA23041100301Page 24 of 39 ShenzhenCTATestingTechnologyCo.,Ltd. Room106,Building1,YibaolaiIndustrialPark,QiaotouCommunity,FuhaiStreet,BaoâanDistrict,Shenzhen,China Tel:+86-75523225875E-mail:[email protected]:http://www.cta-test.cn BLEGFSK1Mpbs CH00 CH19 CH39 ReportNo.:CTA23041100301Page 25 of 39 ShenzhenCTATestingTechnologyCo.,Ltd. Room106,Building1,YibaolaiIndustrialPark,QiaotouCommunity,FuhaiStreet,BaoâanDistrict,Shenzhen,China Tel:+86-75523225875E-mail:[email protected]:http://www.cta-test.cn 4.6Out-of-bandEmissions Limit Inany100kHzbandwidthoutsidethefrequencybandinwhichthespreadspectrumordigitallymodulated intentionalradiatorisoperating,theradiofrequencypowerthatisproducedbytheintentionalradiatorshallbe atleast20dBbelowthatinthe100kHzbandwidthwithinthebandthatcontainsthehighestlevelofthe desiredpower,basedoneitheranRFcon-ductedoraradiatedmeasurement,pro-videdthetransmitter demonstratescompliancewiththepeakconductedpowerlimits.Ifthetransmittercom-plieswiththe conductedpowerlimitsbasedontheuseofRMSaveragingoveratimeinterval,aspermittedunder paragraph(b)(3)ofthissection,theattenuationrequiredunderthisparagraphshallbe30dBinsteadof20dB. Attenuationbelowthegenerallimitsspecifiedin§15.209(a)isnotrequired. TestProcedure ConnectthetransmitteroutputtospectrumanalyzerusingalowlossRFcable,andsetthespectrumanalyzer toRBW=100kHz,VBW=300kHz,peakdetector,andmaxhold.Measurementsutilizingthesesettingare madeofthein-bandreferencelevel,bandedgeandout-of-bandemissions. TestConfiguration EUT SPECTRUM ANALYZER TestResults Remark:Themeasurementfrequencyrangeisfrom30MHztothe10thharmonicofthefundamental frequency.Thelowest,middleandhighestchannelsaretestedtoverifythespuriousemissionsandbandage measurementdata. Testplotasfollows: ReportNo.:CTA23041100301Page 26 of 39 ShenzhenCTATestingTechnologyCo.,Ltd. Room106,Building1,YibaolaiIndustrialPark,QiaotouCommunity,FuhaiStreet,BaoâanDistrict,Shenzhen,China Tel:+86-75523225875E-mail:[email protected]:http://www.cta-test.cn GFSK1Mbps(CH00) GFSK1Mbps(CH19) referencereference 30MHz-1G30MHz-1G 1G-26.5G1G-26.5G ReportNo.:CTA23041100301Page 27 of 39 ShenzhenCTATestingTechnologyCo.,Ltd. Room106,Building1,YibaolaiIndustrialPark,QiaotouCommunity,FuhaiStreet,BaoâanDistrict,Shenzhen,China Tel:+86-75523225875E-mail:[email protected]:http://www.cta-test.cn GFSK1Mbps(CH39) reference 30MHz-1G 1G-26.5G ReportNo.:CTA23041100301Page 28 of 39 ShenzhenCTATestingTechnologyCo.,Ltd. Room106,Building1,YibaolaiIndustrialPark,QiaotouCommunity,FuhaiStreet,BaoâanDistrict,Shenzhen,China Tel:+86-75523225875E-mail:[email protected]:http://www.cta-test.cn Band-edgeMeasurementsforRFConductedEmissions: BLEGFSK1Mpbs LeftbandedgeRightbandedge ReportNo.:CTA23041100301Page 29 of 39 ShenzhenCTATestingTechnologyCo.,Ltd. Room106,Building1,YibaolaiIndustrialPark,QiaotouCommunity,FuhaiStreet,BaoâanDistrict,Shenzhen,China Tel:+86-75523225875E-mail:[email protected]:http://www.cta-test.cn 4.7AntennaRequirement StandardApplicable Forintentionaldevice,accordingtoFCC47CFRSection15.203: Anintentionalradiatorshallbedesignedtoensurethatnoantennaotherthanthatfurnishedbythe responsiblepartyshallbeusedwiththedevice.Theuseofapermanentlyattachedantennaorofan antennathatusesauniquecouplingtotheintentionalradiator,themanufacturermaydesignthe unitsothatabrokenantennacanbereplacedbytheuser,buttheuseofastandardantennajackor electricalconnectorisprohibited FCCCFRTitle47Part15SubpartCSection15.247(c)(1)(I): (i)Systemsoperatinginthe2400-2483.5MHzbandthatisusedexclusivelyforfixed.Point-to-point operationsmayemploytransmittingantennaswithdirectionalgaingreaterthan6dBiprovidedthe maximumconductedoutputpoweroftheintentionalradiatorisreducedby1dBforevery3dBthat thedirectionalgainoftheantennaexceeds6dBi. AntennaConnectedConstruction Themaximumgainofantennawas1.92dBi. Remark:Theantennagainisprovidedbythecustomer ,iftâŚ
Text truncated - open the document above for the full version.
FCCID:2A9E6-PATTON TestSetupPhotosoftheEUT
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 2.40 GHz - 2.48 GHz | 3.00 mW |

Electric unicycle
Equipment Class
DTS - Digital Transmission System