FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Shenzhen Fuwit Technology Co., Ltd/
  3. 2A9GZ-FUGA25P2

2A9GZ-FUGA25P2Positioning base station

Shenzhen Fuwit Technology Co., Ltd
Positioning base station - FCC ID 2A9GZ-FUGA25P2 - Shenzhen Fuwit Technology Co., Ltd
Click to zoom

Application Details

Equipment Class
DTS - Digital Transmission System
Date of Grant
Apr 16, 2024
Application Purpose
Original Equipment
Date of Application
Apr 16, 2024
Equipment Note
Positioning base station
Frequency Range
2402.00000000 - 2480.00000000
Company
Shenzhen Fuwit Technology Co., Ltd
Country
China

Documents & Files

Select a file to view

Users Manual

↗

Attestation Statements

↗
↗
↗

Cover Letter(s)

↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗
↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

ShenzhenFuwitTechnologyCo.,Ltd https://www.fuwit.com.cn 承认书 SPECIFICATIONFORAPPROVAL 客户 CUSTOMER 客户编号 CUSTOMERPARTNO: 品名编号 DESCRIPTIONNO . Positioningbasestation 提出日期 PRESENTDAY : 2023/03/26 出图 DRAWING 客户承认 CUSTOMERAPPROVE 发行 MADE 检查 CHECKED 承认 APPROVED 1.Berry2.Boby3.Henry DATE:2023/03/26DATE: 深圳市铨顺宏科技有限公司 ShenZhenFuwitTechnologyCo.,Ltd. 表单编号:ST-R03-10 ShenzhenFuwitTechnologyCo.,Ltd https://www.fuwit.com.cn 1.ProductIntroduction ProductName:Positioningbasestation Productmodel:FU-GA25-P2 Productappearance: 2.packinglist CategoryQuantity CL-GA25-P21 Installationdiskrack1 CertificateofConformity1 InstallingscrewsKA4*30andplugs(1screw+1plug)x4 Waterproofconnector4-pieceset2 ShenzhenFuwitTechnologyCo.,Ltd https://www.fuwit.com.cn 3.Productspecifications NameDescription Dimensions180.7mm×180.7mm×39.36mm Working frequencyband 2.401GHz–2.481GHz Operating temperature -20°C~60°C Power consumption <2W Installationheight≤10m Thepowersupply method ThepowersupplymethodsavailablearestandardPoE(IEEE802.3af/at)and DCpowersupplywithavoltagerangeof12-30Vandacurrentof1A. 4.Interfaceandinstallationinstructions Interface  RJ45*2:DividedintoPoEINandPoEOUT,itisapoweranddatatransmissioninterface.Itcanbeconnected toastandardPoEswitchoroursimilardual-portbasestationthroughanEthernetcable.  DCinterface:PowersupplyvoltagecompatiblewithPSEpowersupply.  Resethole:Resetbuttontorestoredefaultsettings.Pressandholdfor3seconds.Thebasestation'sgreen lightwillflashrapidlyfor5seconds,indicatingthatthebasestationhassuccessfullyrestoredtheinitial settingsandrestarted. RJ45(PoEIN) RJ45(PoEOUT) DCinterface resethole ShenzhenFuwitTechnologyCo.,Ltd https://www.fuwit.com.cn Installation * Beforeinstallation,pleasemakesurethatthefixedpositioncanwithstandaweightof2kgormore .  Asshownintheimagebelow,useKA4screwstosecurelyinstallthediskrackontheflatroof(inthedirection indicatedbythearrow).  Aligntheinstallationbracketwiththedockingpositionandpushthebasestationintothebracketslot.The directionofthenetworkportindicatedonthebracketlatchsurfaceshouldbeconsistentwiththedirectionof thenetworkportindicatedonthebackofthebasestation.  Connecttheupstreamnetworkcabletothebasestation'sRJ45interface(PoEIN).  Iftherearesubordinatecascadedbasestations,connecttheRJ45interface(PoEOUT)ofthebasestationto theRJ45interface(PoEIN)ofthesubordinatebasestationusinganetworkcable.Itisrecommendednotto cascademorethan8levelsofbasestations. 5.RulesforIndicatorLightSignals  AftercorrectlyinstallingthebasestationandcascadingitwithaPoEswitch,thebasestationwill automaticallystart.Onceitisstarted,theoperationalstatusofthebasestationcanbedeterminedthrough indicatorlightsignals.  ThesignalrulesforLEDindicatorlightsareasfollows: LightingstatusBasestationstatus Greenlightflashingrapidly,lastingfor5seconds.Longpressthebasestationstartup/resetbuttonto restart. Redlightflashingrapidly.ObtainingIPaddress. Greenlightflashingslowly.IPaddressobtainedsuccessfully. Greenlightsteadyon.Connectedtopositioningenginesuccessfully. Redlightsteadyon,andthebasestationwill automaticallyresetafter30seconds. Thislevelbasestationismalfunctioning/notconnected. Theredandgreenlightsalternateslowlyflashing.Thedownstreambasestationinthecascadeis malfunctioning. ShenzhenFuwitTechnologyCo.,Ltd https://www.fuwit.com.cn Thelightisdim.Nopowerconnection.  ThesignalrulesfortheRJ45interfaceindicatorlightsaretranslatedasfollows: LEDIndicatorLightStatusBaseStationStatus SteadyOnInterfaceConnectedtoNetwork BlinkingInterfaceDataTransmission LightOffNoNetworkConnection 6.AttentionRequired  WhenselectingPoEpowersupplyforthepositioningbasestation,itisnecessarytousedesignatedstandard PoEpowersupplyequipment(PSEdevicescompliantwithIEEE802.3af/802.3atprotocols).  Theoperatingenvironmentconditionsforthebasestationare-20°Cto60°Ctemperaturerange,0%to95% humidityrange,anditcanbeinstalledoutdoors.TheenclosurehasaprotectionratingofIP66,anditshould bekeptawayfromsourcesoffireandstrongelectromagneticinterference.  Supportsupper-layerapplicationdevelopmentforWeb,iOS,andAndroidplatforms.  Thetheoreticalmaximuminstallationelevationangleis66°,butitisstronglyrecommendednottoexceed 45°. ShenzhenFuwitTechnologyCo.,Ltd https://www.fuwit.com.cn 7.FCCWarning Thisdevicecomplieswithpart15oftheFCCRules.Operationissubjecttothefollowingtwo conditions:(1)Thisdevicemaynotcauseharmfulinterference,and(2)thisdevicemustacceptany interferencereceived,includinginterferencethatmaycauseundesiredoperation. AnyChangesormodificationsnotexpresslyapprovedbythepartyresponsibleforcompliancecouldvoid theuser'sauthoritytooperatetheequipment. ThisequipmenthasbeentestedandfoundtocomplywiththelimitsforaClassBdigitaldevice, pursuanttopart15oftheFCCRules.Theselimitsaredesignedtoprovidereasonableprotectionagainst harmfulinterferenceinaresidentialinstallation.Thisequipmentgeneratesusesandcanradiateradio frequencyenergyand,ifnotinstalledandusedinaccordancewiththeinstructions,maycauseharmful interferencetoradiocommunications.However,thereisnoguaranteethatinterferencewillnotoccurina particularinstallation.Ifthisequipmentdoescauseharmfulinterferencetoradioortelevisionreception, whichcanbedeterminedbyturningtheequipmentoffandon,theuserisencouragedtotrytocorrectthe interferencebyoneormoreofthefollowingmeasures: -Reorientorrelocatethereceivingantenna. -Increasetheseparationbetweentheequipmentandreceiver. -Connecttheequipmentintoanoutletonacircuitdifferentfromthattowhichthereceiveris connected. -Consultthedealeroranexperiencedradio/TVtechnicianforhelp. FCCRFexposurestatement: TheequipmentcomplieswithFCCradiationexposurelimitssetforthforanuncontrolledenvironment. Thisequipmentshouldbeinstalledandoperatedwithminimumdistancebetween20cmtheradiator yourbody.

Attestation Statements

OasisCompliance,Inc.FCCID: 2A9GZ-FUGA25P2 CFR47§2.911(d)(7)FCCUSAgentLetterofAttestation Date:03-28-2024 FCCID:2A9GZ-FUGA25P2FRN:0033117367 To:FederalCommunicationsCommission 7435OaklandMillsRoad Columbia,MD21046 ToWhomItMayConcern, ThisletteristoconfirmthatwehaveacceptedtheresponsibilitytoactasUSAgentonbehalf ofShenzhenFuwitTechnologyCo.,Ltd(“theapplicant”)fortheabovereferencedFCCID. Weareawareoftherequirementsandresponsibilitiesoftheapplicant’sagentforserviceof processasoutlinedintheFCCsection2.911(d)(7)andReportandOrderFCC22-84paragraph 63. U.S.AgentInformation: OasisCompliance,Inc. FRN:0033464157 JamesHe 3313VerdiDr,SanJose,CA95111 Cell:2026028330 Sincerelyyours, JamesHe GlobalMarketAccessManager OasisCompliance,Inc. Email:[email protected]

Attestation Statements

C5266091_X24_Ed.2 1/1 “Attestation Statements” TO: Office of Engineering Technology Federal Communications Commission 7435 Oakland Mills Road Columbia, MD 21046 The Commission adopted rules that prohibit equipment authorization for “covered” telecommunications equipment and video surveillance equipment produced by entities identified on the Commission’s Covered List 1 , which is periodically updated. See the Covered List for more details. This Attestation Statement is to confirm that we follow the Section 2.911(d)(5)(i)-(ii) Applicant Company name: Shenzhen Fuwit Technology Co., Ltd FRN: 0033117367 Grantee code: 2A9GZ FCC ID: 2A9GZ-FUGA25P2 Contact Name: Chunlei Shi Address: 3613 Changping Business Building, No. 99, Honghua Road, Futian Free Trade Zone, Shenzhen Telephone No: 0755-82787626-811 Fax No: 0755-82787626-811 Email: [email protected] i. [Shenzhen Fuwit Technology Co., Ltd] (“the applicant”) certifies that the equipment for which authorization is sought is not “covered” equipment prohibited from receiving an equipment authorization pursuant to section 2.903 of the FCC rules. The applicant must sign this certification. ii. [ Shenzhen Fuwit Technology Co., Ltd] (“the applicant”) certifies that, as of the date of the filing of the application, the applicant is not (as a specifically named entity or any of its subsidiaries or affiliates) identified on the Covered List as an entity producing “covered” equipment. The applicant must sign this certification. Shenzhen Fuwit Technology Co., Ltd certifies that, as of the date of the filing of the application, the applicant is not identified on the Covered List as an entity producing “covered” equipment. Date: 04.08.2024 Applicant’s Name: Chunlei Shi Title: general manager Signature 1 The Commission’s Covered List is published by the Public Safety and Homeland Security Bureau and posted on the Commission’s website. This Covered List, which is periodically updated, identifies particular equipment, produced by particular entities, that constitutes “covered” equipment. https://www.fcc.gov/supplychain/coveredlist

Attestation Statements

CFR47 §2.911(d)(7)AgentDesignationAttestation Date:03-28-2024 FCCID: 2A9 GZ-FUGA25P2FRN:0033117367 To:FederalCommunicationsCommission 7435OaklandMillsRoad Columbia,MD 21046 ShenzhenFuwitTechnologyCo., Ltd(“the applicant”) as requiredby section2.911(d)(7), designatesthe followingagent,locatedin the UnitedStates,for purposesof actingas the applicant’s agentfor serviceof process. The applicantacknowledgesthat they will maintainan agentfor no less thanone year afterthe granteehas terminatedall marketingand importationor the conclusionof any Commission- relatedproceedinginvolvingthe equipment.The applicantfurtheracknowledgestheir responsibilityto informthe FCCwheneverthe agentinformationchanges. U. S. AgentInformation: James He Oasis Compliance, Inc. 3313 Verdi Dr, San Jose, CA 95111 [email protected] cell:2026028330 FRN: 0033464157 Sincerelyyours, ChunleiShi Manager ShenzhenFuwitTechnologyCo., Ltd Address:3613ChangpingBusinessBuilding,No. 99, HonghuaRoad,FutianFreeTradeZone, Shenzhen,China Email:[email protected] Phone:+86 0755-287626-811

Cover Letter(s)

C5266091_X8_Ed.1 1/1 Letter of Authorization Company: Shenzhen Fuwit Technology Co., Ltd Address: 3613 Changping Business Building, No. 99, Honghua Road, Futian Free Trade Zone, Shenzhen Product Name: Positioning base station Model Number: FU-GA25-P2 FCC Identifier: 2A9GZ-FUGA25P2 We authorize LGAI Technological Center S.A., Ronda de la Font del Carme, s/n, 08193 Bellaterra, Spain, to act on our behalf on all matters concerning the above named equipment. Any individual within LGAI Technological Center S.A. is authorized to act on our behalf and take action on the application. We declare that authorize LGAI Technological Center S.A., Ronda de la Font del Carme, s/n, 08193 Bellaterra, Spain, is allowed to forward all information related to the approval project to the Federal Communication Commission and to discuss any issues concerning the approval application. Any and all acts carried out by LGAI Technological Center S.A. on our behalf shall have the same effect as acts of our own. Name: Chunlei Shi Date: 4/8/2024 Title: general manager Signature of applicant:

Cover Letter(s)

C5266091_X10_Ed.2 1/1 Shenzhen Fuwit Technology Co., Ltd Office of Engineering Technology Federal Communications Commission 7435 Oakland Mills Road Columbia, MD 21046 Date: 4/8/2024 Subject: Request for Confidentiality FCC ID: 2A9GZ-FUGA25P2 To Whom It May Concern, Pursuant to the provisions of Sections 0.457 and 0.459 of Commission's rules (47CFR0.457, 0.459), we are requesting the Commission to withhold the following attachment(s) as confidential document from public disclosure. Exhibits Long-Term Confidentiality Short-Term Confidentiality NOTE 2 ID Label/Location No No Attestation Statement No No External Photos No ☐ Block Diagram ☒ ☐ Schematics ☒ ☐ Test Report No No Test Setup Photos No ☐ User’s Manual ☐ NOTE 1 ☐ Internal Photos ☐ NOTE 1 ☐ Parts List / Tune Up ☐ ☐ RF Exposure Info No No Operational Description ☒ ☐ Cover Letter(s) No No SDR Software / Security Info ☐ No NOTE 1: Long-Term Confidentiality may be permitted under special conditions (See II. LONG-TERM CONFIDENTIALITY, Section 3 of KDB 726920, use last in force) NOTE 2: Short-Term Confidentiality can be requested for a maximum of 180 days from the date of the grant. Above mentioned document contains detailed system and equipment description are considered as proprietary information in operation of the equipment. The public disclosure of above documents might be harmful to our company and would give competitor an unfair advantage in the market. In case of short-term Confidentiality, the applicant requests the exhibits selected above are withheld from public view for a period of ______ days from the date of the Grant of Equipment Authorization and prior to marketing. It is our understanding that all measurement test reports, FCC ID label format and correspondent during certification review process cannot be granted as confidential documents and those information will be available for public review once the grant of equipment authorization is issued. C5266091_X10_Ed.2 1/1 Sincerely, Signature: Name: Chunlei Shi Title: general manager

External Photos

Page 1 of 4 Address: 101, No. 7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao’an District, Shenzhen, Guangdong, China Tel : (8 6-755)88850135 Fax: (86-755) 88850136 Web: www.mtitest.com E-mail: [email protected] Photographs of the EUT (External Photos) Model: FU-GA25-P2 Page 2 of 4 Address: 101, No. 7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao’an District, Shenzhen, Guangdong, China Tel : (8 6-755)88850135 Fax: (86-755) 88850136 Web: www.mtitest.com E-mail: [email protected] Page 3 of 4 Address: 101, No. 7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao’an District, Shenzhen, Guangdong, China Tel : (8 6-755)88850135 Fax: (86-755) 88850136 Web: www.mtitest.com E-mail: [email protected] Page 4 of 4 Address: 101, No. 7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao’an District, Shenzhen, Guangdong, China Tel : (8 6-755)88850135 Fax: (86-755) 88850136 Web: www.mtitest.com E-mail: [email protected]

ID Label/Location Info

Name: Positioning base station Model : FU-GA25-P2 Power Input : 48V Power Potput : 802.3af/at(POE Out) FCC ID :2A9GZ-FUGA25P2 型号 标贴(Model label) MAC 标 贴(MAC label) 铭牌位置 (Label position) FCC ID:2A9GZ-FUGA25P2

Internal Photos

Page 1 of 8 Address: 101, No. 7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao’an District, Shenzhen, Guangdong, China Tel : (8 6-755)88850135 Fax: (86-755) 88850136 Web: www.mtitest.com E-mail: [email protected] Photographs of the EUT (Internal Photos) Model: FU-GA25-P2 Page 2 of 8 Address: 101, No. 7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao’an District, Shenzhen, Guangdong, China Tel : (8 6-755)88850135 Fax: (86-755) 88850136 Web: www.mtitest.com E-mail: [email protected] ANT Page 3 of 8 Address: 101, No. 7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao’an District, Shenzhen, Guangdong, China Tel : (8 6-755)88850135 Fax: (86-755) 88850136 Web: www.mtitest.com E-mail: [email protected] Page 4 of 8 Address: 101, No. 7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao’an District, Shenzhen, Guangdong, China Tel : (8 6-755)88850135 Fax: (86-755) 88850136 Web: www.mtitest.com E-mail: [email protected] Page 5 of 8 Address: 101, No. 7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao’an District, Shenzhen, Guangdong, China Tel : (8 6-755)88850135 Fax: (86-755) 88850136 Web: www.mtitest.com E-mail: [email protected] Page 6 of 8 Address: 101, No. 7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao’an District, Shenzhen, Guangdong, China Tel : (8 6-755)88850135 Fax: (86-755) 88850136 Web: www.mtitest.com E-mail: [email protected] Page 7 of 8 Address: 101, No. 7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao’an District, Shenzhen, Guangdong, China Tel : (8 6-755)88850135 Fax: (86-755) 88850136 Web: www.mtitest.com E-mail: [email protected] Page 8 of 8 Address: 101, No. 7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao’an District, Shenzhen, Guangdong, China Tel : (8 6-755)88850135 Fax: (86-755) 88850136 Web: www.mtitest.com E-mail: [email protected]

RF Exposure Info

Address: 101, No. 7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao’an District, Shenzhen, Guangdong, China. Tel: (86-755)88850135 Fax: (86-755) 88850136 Web: www.mtitest.com E-mail: [email protected] RF EXPOSURE Test Report Report No.: MTi230621033-32E2 Date of issue: 2024-03-14 Applicant: Shenzhen Fuwit Technology Co.,Ltd Product: Positioning base station Model(s): FU-GA25-P2 FCC ID: 2A9GZ-FUGA25P2 Shenzhen Microtest Co., Ltd. http://www.mtitest.com - Page 2 of 5 - Report No.: MTi230621033-32E2 Address: 101, No. 7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao’an District, Shenzhen, Guangdong, China. Tel: (86-755)88850135 Fax: (86-755) 88850136 Web: www.mtitest.com E-mail: [email protected] Instructions 1. The report shall not be partially reproduced without the written consent of the laboratory; 2. The test results of this report are only responsible for the samples submitted; 3. This report is invalid without the seal and signature of the laboratory; 4. This report is invalid if transferred, altered or tampered with in any form without authorization; 5. Any objection to this report shall be submitted to the laboratory within 15 days from the date of receipt of the report. - Page 3 of 5 - Report No.: MTi230621033-32E2 Address: 101, No. 7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao’an District, Shenzhen, Guangdong, China. Tel: (86-755)88850135 Fax: (86-755) 88850136 Web: www.mtitest.com E-mail: [email protected] Test Result Certification Applicant: Shenzhen Fuwit Technology Co.,Ltd Address: Room 3613, Changping Business Building, No. 99, Redflower Road, Futian Free Trade Zone, Shenzhen Manufacturer: Shenzhen Fuwit Technology Co.,Ltd Address: Room 3613, Changping Business Building, No. 99, Redflower Road, Futian Free Trade Zone, Shenzhen Product description Product name: Positioning base station Trademark: FUWIT Model name: FU-GA25-P2 Serial Model: N/A Standards: N/A Test procedure: KDB 447498 D01 v06 Date of Test Date of test: 2024-02-29 to 2024-03-14 Test result: Pass Test Engineer : (Letter Lan) Reviewed By: : (Leon Chen) Approved By: : (Tom Xue) - Page 4 of 5 - Report No.: MTi230621033-32E2 Address: 101, No. 7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao’an District, Shenzhen, Guangdong, China. Tel: (86-755)88850135 Fax: (86-755) 88850136 Web: www.mtitest.com E-mail: [email protected] RF EXPOSURE EVALUATION According to FCC 1.1310: The criteria listed in the following table shall be used to evaluate the environment impact of human exposure to radio frequency (RF) Radiation as specified in §1.1307(b) Limits for Maximum Permissible Exposure (MPE) MPE Calculation Method Friis transmission formula: Pd= (Pout*G)\ (4*pi*R 2 ) Where Pd= Power density in mW/cm 2 Pout=output power to antenna in mW G= Numeric gain of the antenna relative to isotropic antenna Pi=3.1415926 R= distance between observation point and center of the radiator in cm(20cm) Pd the limit of MPE, 1mW/cm 2 . If we know the maximum gain of the antenna and total power input to the antenna, through the calculation, we will know the distance where the MPE limit is reached. - Page 5 of 5 - Report No.: MTi230621033-32E2 Address: 101, No. 7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao’an District, Shenzhen, Guangdong, China. Tel: (86-755)88850135 Fax: (86-755) 88850136 Web: www.mtitest.com E-mail: [email protected] Measurement Result BT/BLE: Operation Frequency: 2402-2480MHz, Power density limited: 1mW/ cm 2 Power density limited: 1mW/ cm 2 BLE: Channel Freq. (MHz) modulation conducted power Tune-up power (dBm) Max Antenna Evaluation result Power density Limits (dBm) tune-up power Gain (mW/cm 2 ) (mW/cm 2 ) (dBm) (mW) (dBi) Numeric 2402 BLE-1M -0.42 0±1 1 1.259 1.49 1.41 0.0004 1 2440 -0.3 0±1 1 1.259 1.49 1.41 0.0004 1 2480 -0.59 0±1 1 1.259 1.49 1.41 0.0004 1 Conclusion: For the max result: 0.0004≤ 1.0 , No SAR is required. ----END OF REPORT----

Test Report

深圳市力思远通信技术有限公司 天线测试报告 1. 试验设备和条件(Test Equipment&Conditions) 1.1.NetworkAnalyzers:KEYSIGHTP5002A1.2. CommunicationsTest Set: R&S CMW 500 1.3.3 D ChamberTest System:64 探头测试系统 Shenzhen Force Siyuan communication Technology Co., LTD 深圳市力思远通信技术有限公司 2. 样机结构说明件 (Mechanicalinstruction) 天线名称(Antennaname):矩阵天线(Matrixantenna) 天线型号(Model):GA20_P2ANT_V13 总尺寸16.8*16.8mm(6.33in*6.33in) 单个矩阵尺寸:2.8*2.8mm(1.1in*1.1in) 深圳市力思远通信技术有限公司 3.增益/效率/3D图(Gain&Efficiency&3D Pattern) FrequencyID 12345678 Frequency(MHz 24002420243024502460247024802500 Gain(dBi) 1.491.201.00.6-0.2-0.7-1.2-1.3 Efficiency(DB) -5-5-5.2-5.4-6.3-7.2-7.37.5 (2400MHz) 深圳市力思远通信技术有限公司 4.VSWR

Test Report

The test report is only used for customer scientific research, teaching, internal quality control and other purposes, and is for internal reference only. Address: 101, No. 7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao’an District, Shenzhen, Guangdong, China Tel: (86-755)88850135 Fax: (86-755) 88850136 Web: www.mtitest.com E-mail: [email protected] Test Report Report No.: MTi230621033-32E1 Date of issue: 2024-03-14 Applicant: Shenzhen Fuwit Technology Co.,Ltd Product: Positioning base station Model(s): FU-GA25-P2 FCC ID: 2A9GZ-FUGA25P2 Shenzhen Microtest Co., Ltd. http://www.mtitest.com Page 2 of 46 Report No.: MTi230621033-32E1 Address: 101, No. 7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao’an District, Shenzhen, Guangdong, China Tel: (86-755)88850135 Fax: (86-755) 88850136 Web: www.mtitest.com E-mail: [email protected] Instructions 1. This test report shall not be partially reproduced without the written consent of the laboratory. 2. The test results in this test report are only responsible for the samples submitted 3. This test report is invalid without the seal and signature of the laboratory. 4. This test report is invalid if transferred, altered, or tampered with in any form without authorization. 5. Any objection to this test report shall be submitted to the laboratory within 15 days from the date of receipt of the report. Page 3 of 46 Report No.: MTi230621033-32E1 Address: 101, No. 7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao’an District, Shenzhen, Guangdong, China Tel: (86-755)88850135 Fax: (86-755) 88850136 Web: www.mtitest.com E-mail: [email protected] Table of contents 1 General Description ......................................................................................................................... 5 1.1 Description of the EUT ............................................................................................................................... 5 1.2 Description of test modes .......................................................................................................................... 5 1.3 Environmental Conditions .......................................................................................................................... 7 1.4 Description of support units ....................................................................................................................... 7 1.5 Measurement uncertainty .......................................................................................................................... 7 2 Summary of Test Result .................................................................................................................. 8 3 Test Facilities and accreditations ................................................................................................... 9 3.1 Test laboratory ........................................................................................................................................... 9 4 List of test equipment .................................................................................................................... 10 5 Evaluation Results (Evaluation) .................................................................................................... 11 5.1 Antenna requirement ............................................................................................................................... 11 6 Radio Spectrum Matter Test Results (RF) .................................................................................... 12 6.1 Occupied Bandwidth ................................................................................................................................ 12 6.2 Maximum Conducted Output Power ........................................................................................................ 13 6.3 Power Spectral Density ........................................................................................................................... 14 6.4 RF conducted spurious emissions and band edge measurement .......................................................... 15 6.5 Band edge emissions (Radiated) ............................................................................................................ 16 6.6 Radiated emissions (below 1GHz) ......................................................................................................... 21 6.7 Radiated emissions (above 1GHz) .......................................................................................................... 25 Photographs of the test setup ............................................................................................................. 32 Photographs of the EUT....................................................................................................................... 33 Appendix A: DTS Bandwidth ............................................................................................................... 34 Appendix B: Maximum conducted output power ............................................................................... 36 Appendix C: Maximum power spectral density .................................................................................. 38 Appendix D: Band edge measurements ............................................................................................. 40 Appendix E: Conducted Spurious Emission ...................................................................................... 41 Appendix F: Duty Cycle ....................................................................................................................... 44 Page 4 of 46 Report No.: MTi230621033-32E1 Address: 101, No. 7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao’an District, Shenzhen, Guangdong, China Tel: (86-755)88850135 Fax: (86-755) 88850136 Web: www.mtitest.co…

Text truncated - open the document above for the full version.

Test Setup Photos

Page 1 of 1 Address: 101, No. 7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao’an District, Shenzhen, Guangdong, China Tel : (8 6-755)88850135 Fax: (86-755) 88850136 Web: www.mtitest.com E-mail: [email protected] Photographs of the test setup Model: FU-GA25-P2 Radiated emissions (below 1GHz) Radiated emissions (above 1GHz)

Contact Information

Applicant

Chunlei Shi(general manager)
[email protected]0755-82787626-811Fax: 0755-82787626-811

Technical Contact

Shenzhen Microtest Co., LtdLeon Chen
[email protected]86-755 88850135

Shenzhen · China

Test Firm

Shenzhen Microtest Co., Ltd.Phoebe Cui
[email protected]0755 88850135 1393

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.40 GHz - 2.48 GHz900.00 µW
Confidentiality
Long Term
Grant Notes
Output power listed is conducted. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons. End-users must be provided with operating procedures for satisfying RF exposure compliance.