Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
10张成品透明底 10张成品要白底 Instructions for ICEMOUSE BW002 FCC Warning This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Any changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: -- Reorient or relocate the receiving antenna. -- Increase the separation between the equipment and receiver. -- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. -- Consult the dealer or an experienced radio/TV technician for help. The device has been evaluated to meet general RF exposure requirement. The device can be u sed in portable exposure condition without restriction
Nanning Yalei Electronic Technology Co., LTD Agent Authorization Company: Nanning Yalei Electronic Technology Co., LTD Address: No.303, Building A4, C&T Jiangnan Enterprise Park, No.12, Xiajin Road, Jiangnan District, Nanning, Guangxi, China Product Name: ICEMOUSE BW002 Model Number(s): BW002 Product Description: ICEMOUSE BW002 We authorize MiCOM Labs Inc., 575 Boulder Court, Pleasanton, California 94566, USA, to act on our behalf on all matters concerning the certification of above named equipment. We declare that MiCOM Labs Inc. is allowed to forward all information related to the approval and certification of equipment to the regulatory agencies as required and to discuss any issues concerning the approval application. Any and all acts carried out by MiCOM Labs on our behalf shall have the same effect as acts of our own. Signature: Date: 2022-11-25 Name: ZAINING LU Title: CEO Company: Nanning Yalei Electronic Technology Co., LTD
Nanning Yalei Electronic Technology Co., LTD Office of Engineering Technology Federal Communications Commission 7435 Oakland Mills Road Columbia, MD 21046 USA Date: 2022/11/25 Subject; Request for Confidentiality FCC ID: 2A9I7-BW002 To Whom It May Concern, Pursuant to the provisions of the Commission’s rules Title 47 Sections §0.457 and §0.459, we are requesting the Commission to withhold the following attachment(s) as confidential documents from public disclosure indefinitely. These documents contain detailed system and equipment descriptions and are considered as proprietary information in operation of the equipment. The public disclosure of these documents might be harmful to our company and would give competitors an unfair advantage in the market. Schematic Diagram Block Diagram Operational Description In additional to above mentioned documents, in order to comply with the marketing regulations in Title 47 CFR §2.803 and the importation rules in Title 47 CFR §2.1204, while ensuring that business sensitive information remains confidential until the actual marketing of newly authorized devices, we request Short Term Confidentiality of the following attachment(s); User Manual For 45 days, pursuant to Public Notice DA 04-1705. OR For 180 days pursuantto KDB 726920 D01. It is our understanding that all measurement test reports, FCC ID label format and correspondence during the certification review process cannot be granted as confidential documents and this information will be available for public review once the grant of equipment authorization is issued. Sincerely, Signature: Name: ZAINING LU Title: CEO
Shenzhen CTB Testing Technology Co., Ltd. Report No.: CTB221123013RFX Report Tel: 4008-707-283 Web: http://www.ctb-lab.net Page 1 of 4 Model: BW002 External Photos Shenzhen CTB Testing Technology Co., Ltd. Report No.: CTB221123013RFX Report Tel: 4008-707-283 Web: http://www.ctb-lab.net Page 2 of 4 Shenzhen CTB Testing Technology Co., Ltd. Report No.: CTB221123013RFX Report Tel: 4008-707-283 Web: http://www.ctb-lab.net Page 3 of 4 Shenzhen CTB Testing Technology Co., Ltd. Report No.: CTB221123013RFX Report Tel: 4008-707-283 Web: http://www.ctb-lab.net Page 4 of 4
Model: BW002 FCC ID: 2A9I7-BW002 Label Location
Shenzhen CTB Testing Technology Co., Ltd. Report No.: CTB221123013RFX Report Tel: 4008-707-283 Web: http://www.ctb-lab.net Page 1 of 4 Model: BW002 Internal Photos Shenzhen CTB Testing Technology Co., Ltd. Report No.: CTB221123013RFX Report Tel: 4008-707-283 Web: http://www.ctb-lab.net Page 2 of 4 Shenzhen CTB Testing Technology Co., Ltd. Report No.: CTB221123013RFX Report Tel: 4008-707-283 Web: http://www.ctb-lab.net Page 3 of 4 ANT Shenzhen CTB Testing Technology Co., Ltd. Report No.: CTB221123013RFX Report Tel: 4008-707-283 Web: http://www.ctb-lab.net Page 4 of 4
ANT PHTOT L W H 17mm±0.2 3mm±0.2 0.1mm±0.1 3mm 17mm
Shenzhen CTB Testing Technology Co., Ltd. Report No.: CTB221123013RFX Report Tel: 4008-707-283Web: http://www.ctb-lab.net Page 1 of 28 TEST REPORT Compiled by: Reviewed by: Approved by: Chen Zheng Arron Liu Bin Mei / Director N ote: If there is any objection to the inspection results in this report, please submit a written report to the company within 15 days from the date of receiving the report. The test report is effective only with both signature and specialized stamp. This result(s) shown in this report refer only to the sample(s) tested. Without written approval of Shenzhen CTB Testing Technology Co., Ltd. this report can’t be reproduced except in full. The tested sample(s) and the sample information are provided by the client. “*” indicates the testing items were fulfilled by subcontracted lab. “#” indicates the items are not in CNAS accreditation scope. P roduct Name: ICEMOUSE BW002 FCC ID: 2A9I7-BW002 Trademark: N/A Model Number: BW002 Prepared For: Nanning Yalei Electronic Technology Co., LTD Address: No.303, Building A4, C&T Jiangnan Enterprise Park, No.12, Xiajin Road, Jiangnan District, Nanning, Guangxi, China Manufacturer: Nanning Yalei Electronic Technology Co., LTD Address: No.303, Building A4, C&T Jiangnan Enterprise Park, No.12, Xiajin Road, Jiangnan District, Nanning, Guangxi, China Prepared By: Shenzhen CTB Testing Technology Co., Ltd. Address: 1&2/F., Building A, No.26, Xinhe Road, Xinqiao, Xinqiao Street, Bao'an District, Shenzhen, Guangdong, China Sample Received Date: Nov. 14, 2022 Sample tested Date: Nov. 14, 2022 to Nov. 23, 2022 Issue Date: Nov. 23, 2022 Report No.: CTB221123013RFX Te s t Standards FCC Part15.249 ANSI C63.10:2013 Test Results PASS Remark: This is 2.4GHz radio test report. Shenzhen CTB Testing Technology Co., Ltd. Report No.: CTB221123013RFX Report Tel: 4008-707-283 Web: http://www.ctb-lab.net Page 2 of 28 TABLE OF CONTENT Test Report Declaration Page 1. VERSION .......................................................................... 3 2. TEST SUMMARY ................................................................... 4 3. MEASUREMENT UNCERTAINTY ..................................................... 5 4. PRODUCT INFORMATION AND TEST SETUP .......................................... 6 4.1 Product Information .................................................................... 6 4.2 Test Setup Configuration ............................................................... 6 4.3 Support Equipment .................................................................... 6 4.4 Channel List .......................................................................... 7 4.5 Test Mode ............................................................................ 7 4.6 Test Environment ...................................................................... 7 5. TEST FACILITY AND TEST INSTRUMENT USED ....................................... 8 5.1 Test Facility ........................................................................... 8 5.2 Test Instrument Used .................................................................. 8 6. AC POWER LINE CONDUCTED EMISSION ............................................ 10 6.1 Block Diagram Of Test Setup .......................................................... 10 6.2 Limit ................................................................................ 10 6.3 Test procedure ....................................................................... 10 6.4 Test Result .......................................................................... 12 7. RADIATED SPURIOUS EMISSION ................................................... 14 7.1 Block Diagram Of Test Setup .......................................................... 14 7.2 Limit ................................................................................ 14 7.3 Test procedure ....................................................................... 15 7.4 Test Result .......................................................................... 16 8. BAND EDGE AND RF COUNDUCTED SPURIOUS EMISSIONS .......................... 21 8.1 Block Diagram Of Test Setup .......................................................... 21 8.2 Limit ................................................................................ 21 8.3 Test procedure ....................................................................... 22 8.4 Test Result .......................................................................... 23 9. BANDWIDTH TEST ................................................................ 24 9.1 Block Diagram Of Test Setup .......................................................... 24 9.2 Limit ................................................................................ 24 9.3 Test procedure ....................................................................... 24 9.4 Test Result .......................................................................... 24 10. ANTENNA REQUIREMENT ......................................................... 26 11. EUT TEST SETUP PHOTOGRAPHS .................................................. 27 (Note: N/A means not applicable) Shenzhen CTB Testing Technology Co., Ltd. Report No.: CTB221123013RFX Report Tel: 4008-707-283 Web: http://www.ctb-lab.net Page 3 of 28 1. VERSION Report N o. Issue Date Description Approved CTB221123013RFX Nov. 23, 2022 Original Valid Shenzhen CTB Testing Technology Co., Ltd. Report No.: CTB221123013RFX Report Tel: 4008-707-283 Web: http://www.ctb-lab.net Page 4 of 28 2. TEST SUMMARY The Product has been tested according to the following specifications: Standard Section Test Item Judgment Remark 15.207 Conducted Emission PASS 15.215 20dB Bandwidth PASS 15.249 Fundamental &Radiated Spurious Emission Measurement PASS 15.205 Band Edge Emission PASS 15.203 Antenna Requirement PASS Remark: Test according to ANSI C63.10-2013. Shenzhen CTB Testing Technology Co., Ltd. Report No.: CTB221123013RFX Report Tel: 4008-707-283 Web: http://www.ctb-lab.net…
Text truncated - open the document above for the full version.
Shenzhen CTB Testing Technology Co., Ltd. Report No.: CTB221123013RFX Report Tel: 4008-707-283 Web: http://www.ctb-lab.net Page 1 of 2 Model: BW002 Radiated Emission Below 1G Above 1G Shenzhen CTB Testing Technology Co., Ltd. Report No.: CTB221123013RFX Report Tel: 4008-707-283 Web: http://www.ctb-lab.net Page 2 of 2 Conducted Emission
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 2.41 GHz - 2.48 GHz | - |