FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Sanxing Plastics (Dongguan) Co., Ltd/
  3. 2A9LATYY-30

2A9LATYY-30Wireless Mouse

Sanxing Plastics (Dongguan) Co., Ltd
Wireless Mouse - FCC ID 2A9LATYY-30 - Sanxing Plastics (Dongguan) Co., Ltd
Click to zoom

Application Details

Equipment Class
DTS - Digital Transmission System
Date of Grant
Jan 02, 2023
Application Purpose
Original Equipment
Date of Application
Jan 02, 2023
Equipment Note
Wireless Mouse
Frequency Range
2402.00000000 - 2480.00000000
Company
Sanxing Plastics (Dongguan) Co., Ltd
Country
China

Documents & Files

Select a file to view

Users Manual

↗

Attestation Statements

↗

Cover Letter(s)

↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗
↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

WWireless Mouse 7<< FCC Statement This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Any changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications.However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception,which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: -- Reorient or relocate the receiving antenna. -- Increase the separation between the equipment and receiver. -- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. -- Consult the dealer or an experienced radio/TV technician for help. The device has been evaluated to meet general RF exposure requirement. The device can be used in portable exposure condition without restriction

Attestation Statements

Sanxing Plastics (Dongguan) Co., Ltd Model Difference Data:2022.12.30 Product description: Wireless Mouse Model name: TYY-30, TYY-30s Trade Name: YZUBAOIL FCC ID: 2A9LATYY-30 All the model are the same circuit and RF module, except model names . Regards Sincerely Client’s signature : Client’s name / title : Wei Luo(Manager) Contact information / address:Room 102, No.2, Shuiwei Street, Wanjiang Market, Wanjiang Street, Dongguan City, Guangdong Province, China

Cover Letter(s)

Sanxing Plastics (Dongguan) Co., Ltd (2022.12.30) Eurofins Electrical and Electronic Testing NA, Inc. 914 West Patapsco Avenue Baltimore, MD 21230 RE: CONFIDENTIALITY REQUEST FOR (Wireless Mouse / TYY-30, TYY-30s / FCC ID: 2A9LATYY-30 ) To Whom It May Concern: This letter serves as an official request for confidentiality under sections 0.457 and 0.459 of CFR 47. We have requested that the Exhibits Long-Term Confidentiality Short-Term Confidentiality NOTE 2 ID Label/Location No No Attestation Statement No No External Photos No ☐ Block Diagram ☒ ☐ Schematics ☒ ☐ Test Report No No Test Setup Photos No ☐ User’s Manual ☐ NOTE 1 ☐ Internal Photos ☐ NOTE 1 ☐ Parts List / Tune Up ☐ ☐ RF Exposure Info No No Operational Description ☒ ☐ Cover Letter(s) No No SDR Software / Security Info ☐ No required to be submitted with this application be permanently withheld from public review. Above mentioned document contains detailed system and equipment description are considered as proprietary information in operation of the equipment. The public disclosure of above documents might be harmful to our company and would give competitor an unfair advantage in the market. Please contact me if there is any information you may need. Sincerely, Signature: Name: Wei Luo Title: Manager

Cover Letter(s)

Sanxing Plastics (Dongguan) Co., Ltd (2022.12.30) Eurofins Electrical and Electronic Testing NA, Inc. 914 West Patapsco Avenue Baltimore, MD 21230 RE: LETTER OF AGENT AUTHORIZATION To Whom It May Concern: We, the undersigned, hereby authorize (Shenzhen CTB Testing Technology Co., Ltd.) to act on our behalf in all matters relating to application for equipment authorization, including the signing of all documents relating to these matters. We also hereby certify that no party to the application authorized hereunder is subject to the denial of benefits, including FCC benefits, pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C.853(a). This agreement expires one year from the current date. Sincerely, Signature: Name: Wei Luo Title: Manager

External Photos

External Photos

ID Label/Location Info

Model: TYY-30 FCC ID: 2A9LATYY-30 Label Location

Internal Photos

Internal Photos ANT

RF Exposure Info

Shenzhen CTB Testing Co., Ltd. FCC ID: 2A9LATYY-30 Portable device According to §15.247(e)(i) and §1.1307(b)(1), systems operating under the provisions of this section shall be operated in a manner that ensures that the public is not exposed to radio frequency energy level in excess of the Commission’s guidelines. According to KDB447498 D01 General RF Exposure Guidance V06 The 1-g SAR and 10-g SAR test exclusion thresholds for 100 MHz to 6 GHz at test separation distances ≤ 50 mm are determined by: [(max. power of channel, including tune-up tolerance, mW)/(min. test separation distance, mm)]·[√f(GHZ)] ≤ 3.0 for 1-g SAR and ≤ 7.5 for 10-g extremity SAR, where: • f(GHZ) is the RF channel transmit frequency in GHz • Power and distance are rounded to the nearest mW and mm before calculation • The result is rounded to one decimal place for comparison When the minimum test separation distance is < 5 mm, a distance of 5 mm is applied to determine SAR test exclusion. EDR: Modulation Channel Freq. (GHz) Conduct ed power (dBm) Conducte d power (mW) Tune-up power (dBm) Max tune-up power (dBm) Max tune-up power (mW) Distance (mm) Result calculatio n SAR Exclusion threshold SAR test exclusion 2.402 0.821 1.21 0±1 1.00 1.26 <5 0.39023 3.00 YES 2.441 0.746 1.19 0±1 1.00 1.26 <5 0.39338 3.00 YES 2.480 1.29 1.35 1±1 2.00 1.58 <5 0.49918 3.00 YES 2.402 1.597 1.44 1±1 2.00 1.58 <5 0.49127 3.00 YES 2.441 1.554 1.43 1±1 2.00 1.58 <5 0.49524 3.00 YES 2.480 2.064 1.61 2±1 3.00 2.00 <5 0.62843 3.00 YES 2.402 2.02 1.59 2±1 3.00 2.00 <5 0.61847 3.00 YES 2.441 2.003 1.59 2±1 3.00 2.00 <5 0.62347 3.00 YES 2.480 2.501 1.78 2±1 3.00 2.00 <5 0.62843 3.00 YES GFSK π /4DQPSK 8DQPSK BLE: Modulation Channel Freq. (GHz) Conduct ed power (dBm) Conducte d power (mW) Tune-up power (dBm) Max tune-up power (dBm) Max tune-up power (mW) Distance (mm) Result calculatio n SAR Exclusion threshold SAR test exclusion 2.402 -0.713 0.85 0±1 1.00 1.26 <5 0.39023 3.00 YES 2.44 -0.894 0.81 0±1 1.00 1.26 <5 0.39330 3.00 YES 2.480 -0.642 0.86 0±1 1.00 1.26 <5 0.39651 3.00 YES GFSK Conclusion: For the max result : 0.62843≤ FCC Limit 3.0 for 1g SAR.

Test Report

ITEM SPEC. Antenna Type PCB Antenna Center Frequency 2402 MHz 2441 MHz 2480 MHz 2.34 dBi 2.07dBi 1.45 dBi MAX. GAIN 2.34 dBi Polarization Horizontal Azimuth Beam PatternOmni-directional Impedance 50 Ω Antenna Length 3.1cm Antenna Specification Specifications Summary Antenna Photo & Length (mm) Test Address 16 Tzu Chiang Road, Hsinchu Industrial District Hsinchu Hsien 303, Taiwan Test Date 2009-04-14 Test Instrument vector network analyzer - R&S ZVB20 Average Gain(dBi) : -2.48 Mini mum Gain(dBi): -55.18 1. Main antenna : 2402 MHz 1.1 Horizontal Frequency(MHZ): 2402 Antenna Polarity: Horizontal Maximum Value(dBi): 2. 34 Average Gain(dBi) : -8.98 Mini mum Gain(dBi): -62.3 1.2 Vertical Frequency(MHZ): 2402 Antenna Polarity: Vertical Maximum Value(dBi): -4.51 Average Gain(dBi) : -2.54 Mini mum Gain(dBi): -66.98 2. Main antenna : 2441 MHz 2.1 Horizontal Frequency(MHZ): 2441 Antenna Polarity: Horizontal Maximum Value(dBi): 2.07 Average Gain(dBi) : -8.81 Mini mum Gain(dBi): -51.4 2.2 Vertical Frequency(MHZ): 2441 Antenna Polarity: Vertical Maximum Value(dBi): -4.29 Average Gain(dBi) : -3.34 Mini mum Gain(dBi): -53.4 2. Main antenna : 2480 MHz 2.1 Horizontal Frequency(MHZ): 2480 Antenna Polarity: Horizontal Maximum Value(dBi): 1.45 2.2 Vertical Frequency(MHZ): 2480 Antenna Polarity: Vertical Maximum Value(dBi): -4.95 Average Gain(dBi) : -9.06 Minimum Gain(dBi): -60.00

Test Report

Shenzhen CTB Testing Technology Co., Ltd. Report No.: CTB221228032RFX Report Tel: 4008-707-283Web: http://www.ctb-lab.net Page 1 of 35 TEST REPORT Compiled by: Reviewed by: Approved by: Chen Zheng Arron Liu Bin Mei / Director Note: If there is any objection to the inspection results in this report, please submit a written report to the company within 15 days from the date of receiving the report. The test report is effective only with both signature and specialized stamp. This result(s) shown in this report refer only to the sample(s) tested. Without written approval of Shenzhen CTB Testing Technology Co., Ltd. this report can’t be reproduced except in full. The tested sample(s) and the sample information are provided by the client. “*” indicates the testing items were fulfilled by subcontracted lab. “#” indicates the items are not in CNAS accreditation scope. Product Name: Wireless Mouse FCC ID: 2A9LATYY-30 Trademark: YZUBAOIL Model Number: TYY-30, TYY-30s Prepared For: Sanxing Plastics (Dongguan) Co., Ltd Address: Room 102, No.2, Shuiwei Street, Wanjiang Market, Wanjiang Street, Dongguan City, Guangdong Province, China Manufacturer: Sanxing Plastics (Dongguan) Co., Ltd Address: Room 102, No.2, Shuiwei Street, Wanjiang Market, Wanjiang Street, Dongguan City, Guangdong Province, China Prepared By: Shenzhen CTB Testing Technology Co., Ltd. Address: 1&2/F., Building A, No.26, Xinhe Road, Xinqiao, Xinqiao Street, Bao'an District, Shenzhen, Guangdong, China Sample Received Date: Dec. 22, 2022 Sample tested Date: Dec. 22, 2022 to Dec. 30, 2022 Issue Date: Dec. 30, 2022 Report No.: CTB221228032RFX Te s t Standards FCC Part15.247 ANSI C63.10:2013 Test Results PASS Remark: This is Bluetooth radio test report. Shenzhen CTB Testing Technology Co., Ltd. Report No.: CTB221228032RFX Report Tel: 4008-707-283 Web: http://www.ctb-lab.net Page 2 of 35 TABLE OF CONTENT Test Report Declaration Page 1. VERSION ........................................................................................................................................ 3 2. TEST SUMMARY ........................................................................................................................... 4 3. MEASUREMENT UNCERTAINTY ................................................................................................. 5 4. PRODUCT INFORMATION AND TEST SETUP ............................................................................ 6 4.1 Product Information .......................................................................................................................... 6 4.2 Test Setup Configuration .................................................................................................................. 6 4.3 Support Equipment........................................................................................................................... 6 4.4 Channel List ..................................................................................................................................... 7 4.5 Test Mode ........................................................................................................................................ 7 4.6 Test Environment ............................................................................................................................. 7 5. TEST FACILITY AND TEST INSTRUMENT USED ....................................................................... 8 5.1 Test Facility ...................................................................................................................................... 8 5.2 Test Instrument Used ....................................................................................................................... 8 6. AC POWER LINE CONDUCTED EMISSION ................................................................................ 10 6.1 Block Diagram Of Test Setup ......................................................................................................... 10 6.2 Limit ................................................................................................................................................ 10 6.3 Test procedure ............................................................................................................................... 10 6.4 Test Result ..................................................................................................................................... 12 7. RADIATED SPURIOUS EMISSION ............................................................................................. 14 7.1 Block Diagram Of Test Setup ......................................................................................................... 14 7.2 Limit ................................................................................................................................................ 14 7.3 Test procedure ............................................................................................................................... 15 7.4 Test Result ..................................................................................................................................... 16 8. BAND EDGE AND RF COUNDUCTED SPURIOUS EMISSIONS ............................................... 23 8.1 Block Diagram Of Test Setup ......................................................................................................... 23 8.2 Limit ................................................................................................................................................ 23 8.3 Test procedure ............................................................................................................................... 23 8.4 Test Result ..................................................................................................................................... 24 9. COUDUCTED OUTPUT POWER ........................................................…

Text truncated - open the document above for the full version.

Test Setup Photos

Radiated Emission Below 1G Above 1G Conducted emissions

Contact Information

Applicant

Wei Luo(Manager)
[email protected]13827207660Fax: 13827207660

Technical Contact

Sanxing Plastics (Dongguan) Co., LtdWei Luo
[email protected]13827207660

Room 102, No.2, Shuiwei Street, · Dongguan city, Guangdong province, · China

Test Firm

Shenzhen CTB Testing Technology Co., Ltd.Rita Xiao
[email protected]86-13538218145

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.40 GHz - 2.48 GHz860.00 µW
Confidentiality
Long Term
Grant Notes
Output power listed is conducted.